© 2006 Cisco Systems, Inc. All rights reserved.Presentation_ID 1
Configuring Cisco Nexus 5000 Switches in NPV Mode
Module 9
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 2
Objectives
NPV Overview
Configuration of switch in NPV mode
Show commands and troubleshooting
Future NPV features
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 3
N-Port Virtualization (NPV): An Overview
N5K FCOE NPV DeviceUses the same domain(s) as the NPV-core switch(es)
F-port
NPV-Core Switch (MDS or 3rd party switch with NPIV support)
NP-port
FC
VSAN 5
10.1.1Solves the domain-id
explosion problem
FC
20.2.1
VS
AN
10
20.5.1
(no FL ports)
VSAN 15
FC10.5.710.5.2
server port (F)
Target
Initiator
Can have multipleuplinks, on differentVSANs (port channel and trunking in a later release)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 4
NPV: Supported Hardware & Mgmt.
NPV Switch Mode Supported on:
All MDS blade switches
MDS switches (9124, 9134, etc.)
Nexus 5020, 5010
UCS 6100
NPV-Core Switch MDS 9513, MDS 9509, 3rd party switch with NPIV support (Support Matrix)
Management NPV device has it’s own IP address and management port – for mgmt. & debugging
All relevant configs. are supported via SNMP and CLI
FM support for discovering and configuring NPV switches (e.g. NP port mode)
No change in image upgrade and installation procedure
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 5
NPV Features Continued
Different uplinks from an NPV device can be connected in different VSANs ( Trunking and Port Channeling of F ports will be supported in a later release)
If one of the uplink fails then the corresponding servers would be logged in via other uplinks (if any) automatically
Zoning, DPVM…, are enforced on the NPV-core switch only
Domain manager, FSPF, Zone server, Fabric login sever, Name server do not run on the NPV device
Local switching is disabled – all traffic routed via the NPV-core switch
No license required for NPV functionality
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 6
NPV: Internal Logins (FLOGIs)
When an NP port comes up NPV itself first FLOGIs into the core
npv-core# show fcns database detail ------------------------VSAN:1 FCID:0x010001------------------------port-wwn (vendor) :20:02:00:0d:ec:2f:c1:40 (Cisco) node-wwn :20:01:00:0d:ec:2f:c1:41class :2,3node-ip-addr :172.20.150.38ipa :ff ff ff ff ff ff ff fffc4-types:fc4_features :npv symbolic-port-name :para-3:fc1/2symbolic-node-name :para-3port-type :N port-ip-addr :0.0.0.0fabric-port-wwn :20:02:00:0d:ec:04:99:40hard-addr :0x000000permanent-port-wwn (vendor) :20:02:00:0d:ec:2f:c1:40 (Cisco)
NPV
NPV-Core Switch
NPfc1/2
F P1
P2fwwn of Port P1
fww
n of
Por
t P2
VSAN
WW
N of
NPV
switch name of NPV &
Interface name of P2
IP A
ddre
ss o
f NPV
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 7
NPV: Logins from End Devices (FDISCs)
An end port logs into the npv-core as follows:
VSAN:1 FCID:0x331e00------------------------port-wwn (vendor) :2f:ff:00:06:2b:10:c4:4c (LSI) node-wwn :2f:ff:00:06:2b:10:c4:4cclass :3node-ip-addr :0.0.0.0ipa :ff ff ff ff ff ff ff fffc4-types:fc4_features :scsi-fcp:init symbolic-port-name :LSI7404XP-LC BR A.1 03-01081-03A FW:01.03.17 Port 0 symbolic-node-name :port-type :N port-ip-addr :0.0.0.0fabric-port-wwn :20:02:00:0d:ec:04:99:40hard-addr :0x000000permanent-port-wwn (vendor) :20:02:00:0d:ec:2f:c1:40 (Cisco)
NPV
NPV-Core Switch
NPfc1/2
F P1
P2
fc1/1
N
F P3
P4
LSIFCID 0X331e00
fwwn of Port P1
fwwn of Port P2
NPV converts FLOGI to FDISC
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 8
NPV: Distribution of end Device Logins
NPV
NPV-Core Switch
NP Ports P1 P2 P3
NP Port No. of mapped F ports
P1 5 (fc1/1, 1/5 ...)
P2 2 (fc1/7, fc1/21)
P3 9 (fc1/2, fc1/8, ...)
Next F port on NPV would be assigned to NP Port P2FC
F
An example of current mapping of ports
(NP port with minimum number of mapped F ports)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 9
NPV: What happens when an NP port goes down?
All F ports mapped to that NP port are re-initialized (shut no shut)
These N ports would attempt re-login
If another NP port is available
N ports would be logged in via the available NP port(s)
Logins would be distributed as per the previous slide
If no NP port is available
F ports would remain in down state waiting for an NP port
When the failed NP port comes back up
The logins are NOT re-distributed (to avoid disruption)
NPV
NP Ports
P1 P2 P3
F F F
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 10
NPV: What happens when an F port goes down?
NPV sends a LOGO to NPV-core on behalf of the N port
If there were multiple FCIDs assigned to that N port (NPIV-enabled host) then a LOGO is sent to the NPV-core for each FCID
The F port is not allowed to come back up until the LOGO(s) are completed
Conflict in Port-security,DPVM or FC-SP configurationon NPV-code switch can logout an FCID or prevent it from coming up
NPV
NP Ports P1 P2 P3
FC
F
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 11
NPV Feature
NPV is enabled with the following commands:switch(config)# feature fcoe
2008 Aug 6 19:02:21 switch %$ VDC-1 %$ %PFMA-2-FC_LICENSE_DESIRED: FCoE/FC feature will be enabled after the configuration is saved followed by a reboot
switch(config)# npv enable
Verify that boot variables are set and the changes are saved. Changing to npv mode erases the current configuration and reboots the switch in npv mode. Do you want to continue? (y/n): This does a write-erase and reloads the switch in NPV mode (same image)
“no npv enable” to go back to non-npv mode (also involves write-erase and reload)
Only the following port modes allowed: NP (a new port mode), F and SD If there are multiple uplinks then the server logins are equally distributed
amongst them Uplinks from an NPV device can be connected to multiple aggregation
switches
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 12
NPV: Configuration
NPV
NP Port P1 (fc3/4)
FC
F
NPV-Core Switch
1. Enable NPIV on NPV-Core switch npv-core(config)# npiv enable
2. Set port mode of P2 to Fnpv-core(config)# interface fc8/14npv-core(config)# switchport mode F
3. Set the Port VSAN of this F portnpv-core(config)# vsan databasenpv-core(config-vsan-db)# vsan 5 interface fc8/14
4. Enable NPV on Nexus 5020npv(config)# npv enablenpv switch would reboot
5. Set Port mode of P1 to NPnpv(config)# interface fc3/4npv(config-if)# switchport mode NP
6. Set Port mode of P3 to Fnpv(config)# interface vfc19/1npv(config-if)# switchport mode F
7. Set the Port VSAN of NP and VFC port to be same as the F port on NPV-core switchnpv(config)# vsan database
npv(config-vsan-db)# vsan 5 interface fc3/4npv(config-vsan-db)# vsan 5 interface vfc23/1
8. No shut ports P1, P2, and P3
P2 (fc8/14)
P3 (vfc23/1)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 13
NPV: Default Port Mode Configuration
switch# show interface brief
-------------------------------------------------------------------------------Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps)-------------------------------------------------------------------------------fc3/1 1 NP -- down swl -- --fc3/2 1 NP -- down swl -- --…
By default the FC ports come up as NP
They can be modified:switch(config)# int fc3/1switch(config-if)# switchport mode f
switch# show interface brief
-------------------------------------------------------------------------------Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps)-------------------------------------------------------------------------------fc3/1 1 F -- down swl -- --fc3/2 1 NP -- down swl -- --…
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 14
NPV Related Show Commands on NPV Switch
The following show commands can be used on the NPV switch to display info.
show npv flogi-table
show npv status
show tech-support npv
show npv internal event-history { errors | events | ext-if-fsm [ <interface > ] | flogi-fsm [ interface < interface > | pwwn <wwn> ] }
show npv internal event-history msgs
show npv internal event-history svr-if-fsm [ interface < interface > ]
show npv internal info
show npv internal info external-interface { all | < interface > }
show npv internal info global
show npv internal info interface { all | < interface > }
show npv internal info server-interface { all | < interface > }
show npv internal mem-stats [ detail ]
show npv internal pending-queue interface { all | < interface >
debug npv { all | erros | events | ... }
show debug npv
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 15
NPV Related Show Commands on NPV Switch
switch# sh npv flogi-table
--------------------------------------------------------------------------------
SERVER EXTERNAL
INTERFACE VSAN FCID PORT NAME NODE NAME INTERFACE
--------------------------------------------------------------------------------
vfc23/1 5 0xa40001 10:00:00:00:c9:3c:f4:82 20:00:00:00:c9:3c:f4:82 fc3/1
Total number of flogi = 1.
switch# show npv status
npiv is disabled
External Interfaces:
====================
Interface: fc3/1, VSAN: 5, FCID: 0xa40000, State: Up
Number of External Interfaces: 1
Server Interfaces:
==================
Interface: vfc19/1, State: Initializing
Interface: vfc23/1, VSAN: 5, State: Up
Number of Server Interfaces: 2
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 16
NPV Related Show Commands on NPV Switch
switch# show npv internal info
NPV Globals:
============
NPV mode: ENABLED
Switch-Name: switch
Switch Mgmt IP Address: 172.18.217.80
proxy logo Retries: 1
Internal FLOGI max timeout Retries: -1
NS Registration max timeout Retries: 5
External Interface Info:
========================
Interface Information:
ifindex: fc3/1, VSAN: 5, internal FLOGI fcid: 0xa40000
FSM current state: NPIVP_EXT_IF_ST_UP
fabric mgmt addr: 172.18.217.70
fabric pwwn: 20:4d:00:0d:ec:3f:a5:c0, fabric nwwn: 20:05:00:0d:ec:3f:a5:c1
my pwwn: 20:81:00:0d:ec:6b:cd:40, my nwwn: 20:05:00:0d:ec:6b:cd:41
Port Parameters:
Rx B2B Credits: 16, Multiplier: 0, Buff Size: 2112
Tx B2B Credits: 16, Multiplier: 0, Buff Size: 2112, bbscn: 0
bbscn_capable: FALSE bbscn_max: 0, port_bbscn: 0
N5K NPV Fabric Login
Timer & Retry Information: Busy Timer (1), id: 10, active: FALSE time remaining: 0 Fail Retry Timer (7), id: 00, active: FALSE time remaining: 0 FDISC Response Timer (2), id: 01, active: FALSE time remaining: 0 Error Clear Timer (6), id: 01, active: TRUE time remaining: 159
Statistics: flogi retry count : 1 ns registration retry count : 0 number of LS_RJTs rcvd : 0 LS_RJT timestamp : Wed Aug 6 20:58:44 2008
pending queue size : 0
FLOGIs on this interface: pwwn : 10:00:00:00:c9:3c:f4:82, fcid : 0xa40001
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 17
NPV Related Show Commands on NPV Switch
VFC (FCOE) interface waiting for FLOGI from host
VFC (FCOE) interface up and working
Interface Information: ifindex: vfc23/1, VSAN: 5, NPIV requested: TRUE, lcp init done: TRUE Selected External Interface: fc3/1 FSM current state: NPIVP_SVR_IF_ST_INTERFACE_UP
Port Parameters: rxbbcredit: 0 rxbufsize: 2112 txbbcredit: 64 txbufsize: 2048 txbbscn: 0 bbscn_capable: FALSE bbscn_max: 0, port_bbscn: 0
Statistics: number of LS_RJTs sent : 0 LS_RJT timestamp : Wed Aug 6 20:58:44 2008
number of FLOGIs: 1
pwwn : 10:00:00:00:c9:3c:f4:82, fcid : 0xa40001, requested fcid : 0x000000, ext ifindex: fc3/1 class: 3 logo retries done: 0, flogi accept sent: TRUE Unknown Timer (0), id: 00, active: FALSE time remaining: 0 FSM current state: NPIVP_FLOGI_ST_STEADY_STATE
switch# show npv internal info (output continued)Server Interface Info:======================
Interface Information: ifindex: vfc19/1, VSAN: 5, NPIV requested: FALSE, lcp init done: TRUE Selected External Interface: fc3/1 FSM current state: NPIVP_SVR_IF_ST_WAITING_FOR_FLOGI
Port Parameters: rxbbcredit: 0 rxbufsize: 2112 txbbcredit: 0 txbufsize: 0 txbbscn: 0 bbscn_capable: FALSE bbscn_max: 0, port_bbscn: 0
Statistics: number of LS_RJTs sent : 0 LS_RJT timestamp : Thu Jan 1 00:00:00 1970
number of FLOGIs: 0
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 18
NPV Related Show Commands on NPV-Core Switch
The following show commands can be used in the NPV-core switch to display information on the NPV devices.
show fcns database npv [ detail [ vsan <vsan range> ]] show fcns database npv [ node_wwn <wwn> ] [ vsan <vsan range> ]
Example Outputs
switch# show fcns database npv
VSAN 5:
----------------------------------------------------------------------------------
NPV NODE-NAME NPV IP_ADDR NPV IF CORE SWITCH WWN CORE IF
----------------------------------------------------------------------------------20:05:00:0d:ec:6b:cd:41 172.18.217.80 fc3/1 20:00:00:0d:ec:3f:a5:c0 fc2/13
Total number of entries = 1
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 19
NPV Related Commands on NPV-Core Switch
switch# show fcns database npv detail------------------------------------------------------------
VSAN:5 NPV Node Name: 20:05:00:0d:ec:6b:cd:41
------------------------------------------------------------
NPV Fabric Port-WWN :20:81:00:0d:ec:6b:cd:40
class :2,3
NPV IP Address :172.18.217.80
ipa :ff ff ff ff ff ff ff ff
fc4-types:fc4_features :npv
NPV Switch Name:Interface :switch:fc3/1
port-type :NP
Core Switch fabric-port-wwn :20:4d:00:0d:ec:3f:a5:c0permanent-port-wwn (vendor) :20:81:00:0d:ec:6b:cd:40 (Cisco)
switch# show fcns data npv node_wwn 20:05:00:0d:ec:6b:cd:41 vsan 5
VSAN 5:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0xa40001 N 10:00:00:00:c9:3c:f4:82 (Emulex) ipfc scsi-fcp:init
Total number of entries = 1