62
NEC NEO Microwave Equipment Introduction Microwave Product Customer Service Dept. 2009-1

Nec neo microwave equipment introduction

Embed Size (px)

Citation preview

Page 1: Nec neo microwave equipment introduction

NEC NEO Microwave Equipment Introduction

Microwave Product Customer Service Dept.

2009-1

Page 2: Nec neo microwave equipment introduction

Contents

Microwave Communication Introduction

PASOLINK NEO Equipment Introduction

PASOLINK NEO Equipment System Configuration

Typical Networking Examples

Page 3: Nec neo microwave equipment introduction

Microwave Communication Introduction

Microwave Communication Concept

Mobile Network Application

Microwave Communication Features

Page 4: Nec neo microwave equipment introduction

秘密▲

Point to Point Digital Microwave transmission system

MUX

Satellite

Fiber optic cable

Microwave link

Coaxial cable

MUX

Microwave Communication Concept

Page 5: Nec neo microwave equipment introduction

秘密▲Microwave Communication Concept

10km 1km 100m 10m 1m 10cm 1cm 1mm

f 30kHz 300kHz 3MHz 30MHz 300MHz 3GHz 30GHz 300GHz

LF MF HF VHF UHF SHF EHF

microwave

Microwave is a kind of electromagnetic wave. Generally speaking, it ranges from

300MHz to 300GHz (wavelength from 1mm to 1m). Microwave communication

normally adopts frequency from 3GHz to 30GHz.

Wavelength ( )=Velocity of light (v)/Frequency (f)

Page 6: Nec neo microwave equipment introduction

秘密▲Mobile Network Application

BSC

MSCPSTNBSC

.....

MSC

SDH

BSC

BSC

BTS

BTS

BTS

BTS

BTS

BTS

BTS

BTSBTS

BTS BTS

BTS

BTS

BTS

BTS

BTS PDH

PDH

BTS

PDHBTS

BTS

BTS

BTS

BTS

BTS

SDH

SDH

SDH

SDH

PDH

PDH

PDH

PDH

PDH

PDH

PDH

SDH SDH

SDH Microwave

PDH Microwave

PSTN: Public Switched Telephone NetworkMSC: Mobile Switching CenterBSC: Base Station ControllerBTS: Base Transceiver Station

Page 7: Nec neo microwave equipment introduction

秘密▲Microwave Communication Features

Wide frequency band has larger capacity for more radio communication equipments.

High transmission quality, High stability and reliability, High antenna gain and High Security.

Easy to deploy, Low cost and Short construction term.

Fast business operation and Easy maintenance.

High resistance against disasters such as earth quake and flood. Less affected by terrain.

Page 8: Nec neo microwave equipment introduction

PASOLINK NEO Equipment Introduction

Equipments Overview

IDU

ODU

Hybrid

System Performance

Page 9: Nec neo microwave equipment introduction

PASOLINK Equipments Overview

PASOLINK Road Map

PASOLINK NEO Overview

Equipment Features

Equipment Application

Page 10: Nec neo microwave equipment introduction

秘密▲

PASOLINK Family Road Map

Page 11: Nec neo microwave equipment introduction

秘密▲

PASOLINK NEO Overview

PASOLINK Built-up

Antenna

Indoor Unit (IDU)

System Configuration

Non-protective (1+ 0)

Protective (1+ 1)

Outdoor Unit (ODU)

Page 12: Nec neo microwave equipment introduction

秘密▲

Equipment Features

High performance, High stability and Low power consumption.

High system gain and High frequency spectrum usage.

STM-1 optical port automatic protection switching.

Cross polarization interference cancellation (XPIC).

10 Base-T /100 Base-TX,1000 Base-SX,1000 Base-T (LAN Ports).

Page 13: Nec neo microwave equipment introduction

秘密▲

Equipment Application

Cellular Network Application

Page 14: Nec neo microwave equipment introduction

IDU Introduction

IDU Overview

IDU Panel Introduction

Equipment Parameters

Application Example (1+1)

IDU Interface Card Summary

IDU Configuration

Interface Card Introduction

Page 15: Nec neo microwave equipment introduction

秘密▲IDU Overview

2 independent Modem modules in IDU

155Mbps (28MHz) transmission ratio for each module

Software changeable modulation/demodulation modes

Various configuration for network development Support 5E1~48E1, STM-1, 10/100base-T Signals

The same hardware platformPDH (16E1/48E1)→SDH (STM-1)

Page 16: Nec neo microwave equipment introduction

秘密▲

Interface Card Summary( 1)

PDH E1

Interface Card E1 LAN Total Capacity

16E1 INTFC D-sub37×2 RJ-45×2 10-80MB

48E1 INTFC MDR68×3 N/A 10-100MB

4P LAN INTFC D-sub37×1 RJ-45×4 10-100MB

2way DXC INTFC D-sub37×2 RJ-45×2 10-80MB

PDH E3

Interface Card E3 WS-E1 WS/SC-LAN Total Capacity

E3 INTFC IEC-min

(2-port)

D-sub37×1 RJ-45×2 40MB(1×E3 & 4×E1)

80MB(2×E3 & 8×E1)

Page 17: Nec neo microwave equipment introduction

秘密▲

Interface Card Summary( 2)

Interface Card MAIN WS( E1) Total Capacity

STM-1 INTFC( ELE) IEC-min N/A STM-1

STM-1 INTFC( OPT) LC N/A STM-1

GbE INTFC LC/RJ-45 N/A 150MB

LAN/WS INTFC Main slot RJ-45×2 N/A 100MB+50MB

75MB+75MB

Best Effort+ Best Effort

Sub slot N/A RJ-45×2

D-sub9

64-256KB(SC)/2M(WS) for SC-LAN

E1 for WS

SDH STM-1

Page 18: Nec neo microwave equipment introduction

秘密▲Interface Card Introduction

E1 × 16 Channels (D-Sub (37pin) × 2, 75/120 ohm S/W selectable)10/100BASE-T(X) × 2 Ports(RJ-45 × 2, Auto-Negotiation / Auto-MDI/MDIX)

16 E1 Interface Card

○: AvailableX: Unavailable

Page 19: Nec neo microwave equipment introduction

秘密▲

E1 & LAN Settings (16E1+2LAN Card)

Interface Card Introduction

Page 20: Nec neo microwave equipment introduction

秘密▲Interface Card Introduction

48E1 Interface Card

Page 21: Nec neo microwave equipment introduction

秘密▲

4P LAN Interface Card

Interface Card Introduction

○: AvailableX: Unavailable

Page 22: Nec neo microwave equipment introduction

秘密▲

Interface Card Introduction

4P LAN Interface Card

Page 23: Nec neo microwave equipment introduction

秘密▲

GbE Interface Card

Interface Card Introduction

○: AvailableX: Unavailable

Page 24: Nec neo microwave equipment introduction

秘密▲

32E1 Interface Card

Interface Card Introduction

○: AvailableX: Unavailable

Page 25: Nec neo microwave equipment introduction

秘密▲

IDU Configuration Introduction

PDH ( 16E1 )

PDH ( 48E1 )

SDH ( STM-1 )

Page 26: Nec neo microwave equipment introduction

秘密▲

IDU Panel Introduction ( 1)

RX: RX Status (Green)

3. XPIC in/out port2. IF cable port1. Grounding bolt

MD/CBL: Alarm (Red)

TX: TX Status (Green) PWR: Power (Green)

4. XPIC CTRL Port

ODU: ODU Alarm (Red)

XPIC Reset: Reset (Yellow)

5. LED lights

Page 27: Nec neo microwave equipment introduction

秘密▲

IDU Panel Introduction( 2)

MEMORY: Memory access (Yellow)

8. E1 interface: MDR7. Power switch6. Power port

MAINT: Maintenance (Yellow)

9. Module Alarm LED

IDU: IDU Alarm (Red)

10. LED Lights

Page 28: Nec neo microwave equipment introduction

秘密▲

IDU Panel Introduction( 3)

15. SC IN/OUT: Service Channel

13. PROTECT: Protection switch

12. call: Calling button

11. MMC: MMC card slot

18. LCT: Local Craft Terminal port14. EOW: EOW phone port

17. NMS/NE: Network management port

16. AUX/ALR: Parallel alarm port

Page 29: Nec neo microwave equipment introduction

秘密▲

Items Parameter Introduction

EnvironmentRequirements

Normal Operation IDU: -5°C ~ +50°C

Able to work IDU: -10°C ~ +55°C

Transport/Storage IDU: -40 °C ~ +70°C

Relative Humidity IDU: Less than 95% at +50°C (no condensation)

Electromagnetic Compatibility Comply with EN301 489-4

Safety Comply with EN60950

Power requirements -48 VDC (-40.5 VDC to -57 VDC), comply with EN300 132-2

Power consumption (Typical)PDH 1+0: 25W SDH 1+0: 27W

1+1: 35W 1+1: 37W

Weight (1+1) IDU: 4.4kg

Dimensions (1+1) 482mm (W) x 44mm (H) x 240mm (D): about 4 kg

Equipment Parameters( 1)Physical Parameters

Page 30: Nec neo microwave equipment introduction

秘密▲Equipment Parameters( 2)

No. ITEM PDH SDH LAN

1 IDU Type 1+0 expandable/1+1

2Modulation

ModeQPSK/16/32QAM 128QAM QPSK/16/32/128QAM

3

Base Band Interface

E1:2.048Mbp s±50ppm E3:34.368±20ppm 155.52Mbps±20ppm10/100Base-T(X)1000Base-SX1000Base-T

75ohm/120ohm 75ohm 75ohm/S-1.1/L-1.1

D-sub37 / MDR68 IEC169-29(1.0/2.3) IEC169-29(1.0/2.3)RJ45(10/100/1000Base-T(X)) LC(1000Base-SX)

Channel Quantity

5/10/16/20/40/48 1/2 1/2 2/4

Total Capacity

10/20/32/40/80/96Mbps 34/68Mbps 155/2X155Mbps *10/20/40/80/100100+50,75+75Mbps

4Service Channel

V11(codirection/contradirection)x2CH , RS-232x2CH

Performance Parameters

Page 31: Nec neo microwave equipment introduction

秘密▲Application Example( 1+1)

XPIC CTRL: For 1+1 protection IDUXIF IN/XIF OUT: For XPIC

Page 32: Nec neo microwave equipment introduction

ODU Introduction

ODU Overview

ODU Performance Parameters

ODU Appearance

Page 33: Nec neo microwave equipment introduction

秘密▲ODU Introduction

Modulation mode:QPSK、 16QAM、 32QAM、 128QAM

Frequency: 7GHz~ 52GHz Comply with ITU-R standard

Page 34: Nec neo microwave equipment introduction

秘密▲ODU Appearance

RX level test connecter IF cable connecter Grounding RF connecter to antenna

Page 35: Nec neo microwave equipment introduction

秘密▲

Item 7G 7G 7.5G 8G 8G 8GFrequency Range 7.125-7.725 7.125-7.725 7.425-7.9 7.725-8.275 8.275-8.5 7.9-8.4

Frequency PlanITU-R

385-6 385-6Annex 1

385-6Annex 4

386-6Annex 1

386-6Annex 3

386-6Annex 4

ChannelSeparation

TX/RX Spacing(MHz)

161 154 245 311.32 119126

151.614

EMC

Power Supply

Item 13G 15G 18G 23G 26G 38G

Frequency Range 12.75-13.25 14.5-15.35 17.7-19.7 21.2-23.6 24.5-26.5 37.0-39.5

Frequency PlanITU-R

F.497-6CEPT/ERCREC 12-02

F.636-3CEPT/ERCREC 12-07

F.595-6F.191

CEPT/ERCREC 12-03

F.637-3CEPT/ERC

REC T/R 13-02Annex A

F.748-3CEPT/ERC

REC T/R 13-02Annex B

F.749-1CEPT/ERC

REC T/R 12-01

ChannelSeparation

RX/TX Spacing(MHz)

266 420728315490

100810103401560

100812001232

1008 1260

EMCPower supply

Comply with ETS300 385 B(-20V-- -60V/ +20V-- +60V)DC

3.5MHz(4MB)/7MHz(8MB)/14MHz(17MB)/28MHz(34MB)

Comply with ETS300 385 B

(-20V-- -60V/ +20V-- +60V) DC

3.5MHz(4MB)/7MHz(8MB)/14MHz(17MB,13.75MHz for 18G)/28MHz(34MB,27.5MHz for 18G)

PASOLINK Frequency Menu 7GHz~ 38GHz

ODU Performance Parameters( 1)

Page 36: Nec neo microwave equipment introduction

秘密▲

Low band High band

Sub-band ChannelTX

(MHz)RX

(MHz) Sub-band ChannelTX

(MHz)RX

(MHz)

A

1 12754.5 13020.5

A

1 13020.512754.5

2 12756.25 13022.25 213022.25 12756.25

3 12758 13024 313024

12758

4 12759.75 13025.75 413025.75 12759.75

5 12761.5 13027.5 513027.5 12761.5

6 12763.25 13029.25 6 13029.2512763.25

7 12765 13031 7 13031 12765

8 12766.75 13032.75 813032.75 12766.75

Example: 13GHz Frequency changeable in the sub-band

ODU Performance Parameters( 2)

Page 37: Nec neo microwave equipment introduction

秘密▲ODU Performance Parameters( 3)

ODU Frequency Example

Page 38: Nec neo microwave equipment introduction

秘密▲

Frequency Band ( GHz )

6 7 - 8 11 13 15 18 23 26 28 32 38

Frequency( GHz )

5.925.925-5-7.127.1255

7.1257.125--

8.58.5

10.710.7--11.7

12.712.75-5-13.213.255

14.2-14.2-15.3515.35

17.7-17.7-19.719.7

21.2-21.2-23.623.6

24.2524.25

27.027.0

27.5-27.5-29.529.5

31.8-31.8-33.433.4

37.0-37.0-40.040.0

Output Power( dBm)

+25+25 +25+25 +21+21 +21+21 +21+21 +19+19 +19+19 +18+18 +18+18 +17+17 +14.5+14.5

Power Control 00 toto 2020 dB,dB, inin 11 dBdB stepstep variablevariable

Frequency Stability

±± 6ppm6ppm

ThresholdThreshold LevelLevel (dBm(dBm measuredmeasured atat AntennaAntenna port)port) BERBER == 1010 -6-6

CSCS == 2828 (27.5)(27.5) MHzMHz

-- 69.569.5 -68.5-68.5 -68.5-68.5 -69-69 -69-69 -69-69 -68.5-68.5 -68.5-68.5 -67-67 -67-67

BERBER == 10-310-3 AboveAbove valuevalue withwith -1.5-1.5 dBdB

System GainSystem Gain (dBm(dBm measuredmeasured atat AntennaAntenna port)port) BERBER == 1010 -6-6

CSCS == 2828 (27.5)(27.5) MHzMHz

94.594.5 89.589.5 89.589.5 9090 8888 8888 86.586.5 86.86.55

8484 81.581.5

BERBER == 1010-3-3 AboveAbove valuevalue withwith +1.5+1.5 dBdB

Max Input PowerMax Input Power -20dBm-20dBm forfor thethe BERBER lessless thanthan 1010-3-3

ResidualResidual BERBER LessLess thanthan 1010-12-12 atat RSLRSL == -30dBm-30dBm

Performance Parameters/128QAM

ODU Performance Parameters( 4)

Page 39: Nec neo microwave equipment introduction

秘密▲ODU Performance Parameters( 5)

AGC Voltage

Page 40: Nec neo microwave equipment introduction

Hybrid

Hybrid Appearance

Hybrid Installation Instruction

Page 41: Nec neo microwave equipment introduction

秘密▲Hybrid Appearance

7/8/10GHz Hybrid 11GHz~ 52GHz Hybrid

Page 42: Nec neo microwave equipment introduction

秘密▲Hybrid Installation Instruction ( 1)

7/8/10GHz Hybrid Installation

Page 43: Nec neo microwave equipment introduction

秘密▲Hybrid Installation Instruction ( 2)

11GHz~52GHz Hybrid Installation

Page 44: Nec neo microwave equipment introduction

System Performance

IDU and ODU Interconnection

Loopback

EOW Operation

System Upgrade

IDU and ODU Compatibility

Page 45: Nec neo microwave equipment introduction

秘密▲

IDU and ODU Interconnection( 1)

RX Signal TX Signal

Frequency

All signals transmit in one IF cable.

140MHz 340MHz

Page 46: Nec neo microwave equipment introduction

秘密▲

No. Item Specification

1 Interconnection 1 coaxial cable (each channel) / 50ohms

2Standard IF Cable

Types5D-FB , 8D-FB (Standard),10D-FB

3 SignalsIF signal, alarm, controlling, monitoring and power supply

4Maximum IF Cable

Length

150 m (5D-FB)300 m (8D-FB)350 m (10D-FB)

5 Cable Equalization Automatic level equalization

6 Temperature Range -33℃~ +50 ℃ (Able to work: -40 ℃~ +55 ℃)

IDU and ODU Interconnection( 2)

Page 47: Nec neo microwave equipment introduction

秘密▲

IDU and ODU Compatibility

Page 48: Nec neo microwave equipment introduction

秘密▲

Loop back

Near-end IF loop

Near-end Local Loop Remote Base-band Loop

Page 49: Nec neo microwave equipment introduction

秘密▲

EOW Operation

Note: EOW can be used in a few links.

Page 50: Nec neo microwave equipment introduction

秘密▲

System Upgrade( 1)

5E1(4P/16Q)

16E1(4P/16Q)

40E1(16Q)

48E1(32Q)

STM-1(128Q)

5E1(10M) 20E1(40M) Key upgrade

16E1(40M) 40E1(80M) Key upgrade & Change module

40E1(80M) 48E1(100M) Key upgrade

48E1(100M) STM-1 Key upgrade & Change module

Page 51: Nec neo microwave equipment introduction

秘密▲

System Upgrade( 2)

1+1 Key Upgrade& Add MODEM Unit

1+0

Add MODEM Unit& Change Interface Card

2 Way DXC fro Repeater

Page 52: Nec neo microwave equipment introduction

Typical Configuration

ODU Installation Configuration

Typical Configuration

Performance Compare

System Configuration

Page 53: Nec neo microwave equipment introduction

秘密▲

ODU Installation Configuration

1+0

1+1

Separated

Integrated

SingleAntenna

Twin Antennas

Separated

Integrated

Separated

Integrated

Hybrid(7dB Loss/Hop)

Page 54: Nec neo microwave equipment introduction

秘密▲

1+0 non-protection type system

System Configuration(1)

Page 55: Nec neo microwave equipment introduction

秘密▲

Hot Standby system (for 11GHz~ 38GHz Band)

System Configuration(2)

Page 56: Nec neo microwave equipment introduction

秘密▲

Hot standby with space diversity (10GHz~52GHz Band)

System Configuration(3)

Page 57: Nec neo microwave equipment introduction

秘密▲

1+1 Twin Path system (Type-1)

System Configuration(4)

Page 58: Nec neo microwave equipment introduction

秘密▲

1+1 Twin Path system (Type-1)

System Configuration(5)

Page 59: Nec neo microwave equipment introduction

秘密▲

2×(1+1 ) XPIC system (Type-2)

System Configuration(6)

Page 60: Nec neo microwave equipment introduction

秘密▲

System Configuration(7)

4×STM-1(1+0) XPIC Configuration

Page 61: Nec neo microwave equipment introduction

秘密▲

Typical Configuration Performance Compare

System

Configuration

Hot standby with space diversity

Frequency

Diversity1+0

Hot standbySame Frequency

Hybrid Loss 0dB 7dB 0dB 7dB

Page 62: Nec neo microwave equipment introduction