66
١ ACTM User Manual Version 1.٠

Actm usermanual

  • Upload
    toolsir

  • View
    87

  • Download
    3

Embed Size (px)

DESCRIPTION

RTU

Citation preview

Page 1: Actm usermanual

١

ACTM User Manual

Version 1.٠

Page 2: Actm usermanual

GPRS/SMS ACTM User Manual

٢

Notice: Copyright The contents of the manual are protected by Chinese law, any organization and/or person cannot copy this manual or part of contents without Arian Ertebat Caspian Co. authorization in written. Trademark ACTM, GPRS ACTM are the logos and trademarks of Arian Ertebat Caspian Co. The other company trademarks and logos in this manual are owned by the owner, Arian does not have the right for those trademarks and logos.

Page 3: Actm usermanual

GPRS/SMS FAM User manual

٣

Contents

CHAPTER ١ INTRODUCTION ........................................................................................................... ٥ ١.١ Objective ..................................................................................................................................................................... ٥ ١.٢ Application ................................................................................................................................................................. ٥ ١.٣ Version......................................................................................................................................................................... ٥ ١.٤ Convention ................................................................................................................................................................. ٦ ١.٥ Technical Support ................................................................................................................................................... ٦ ١.٦ Abbreviations ........................................................................................................................................................... ٧ CHAPTER ٢ PRODUCT INTRODUCTION .................................................................................. ١٠ ٢.١ Introduction ............................................................................................................................................................ ١٠ ٢.١.١ Size ............................................................................................................................................................................. ١١ ٢.١.٢ Accessories ............................................................................................................................................................ ١٢

٢.٢ System function and feature ............................................................................................................................ ١٢ ٢.٢.١ Main function ........................................................................................................................................................ ١٢ ٢.٢.٢ Part of compatible sensor ............................................................................................................................... ١٤

٢.٣ Specification ............................................................................................................................................................ ١٥ CHAPTER ٣ INSTALLATION.......................................................................................................... ١٨ ٣.١ ACTM installation and cable connection .................................................................................................... ١٨ ٣.١.١ Antenna and SIM card installation .............................................................................................................. ١٨ ٣.١.٢ RS٢٣٢ configuration and Power cables installation ............................................................................ ١٨

٣.٢ Sensors installation .............................................................................................................................................. ١٩ ٣.٢.١ DI (Digital Input) sensor installation ......................................................................................................... ٢٠ ٣.٢.٢ AI (Analog Input) Sensor installation ........................................................................................................ ٢١ ٣.٢.٣ DO (Digital Output) device installation ..................................................................................................... ٢١ ٣.٢.٤ TE (Temperature) sensor installation ....................................................................................................... ٢٢ ٣.٢.٥ Wireless Sensor installation ........................................................................................................................... ٢٢ ٣.٢.٦ Camera installation ............................................................................................................................................ ٢٢ ٣.٢.٧ RTU device installation .................................................................................................................................... ٢٣

٣.٣ Grounding ................................................................................................................................................................ ٢٤ ٣.٤ Power supply .......................................................................................................................................................... ٢٤ ٣.٥ Check the mobile network ................................................................................................................................ ٢٤ CHAPTER ٤ TERMINAL CONFIGURATION ............................................................................. ٢٦ ٤.١ Device Connection ................................................................................................................................................ ٢٦ ٤.٢ Parameter Configuration ................................................................................................................................... ٢٨

Page 4: Actm usermanual

GPRS/SMS FAM User manual

٤

٤.٣ Parameter Detail ................................................................................................................................................... ٣٢ CHAPTER ٥ TYPICAL APPLICATION ......................................................................................... ٤٨ ٥.١ SMS alarm application ........................................................................................................................................ ٤٨ ٥.٢ ACTM management platform application .................................................................................................. ٤٩ ٥.٣ Transparent data transmission application ............................................................................................. ٥١ CHAPTER ٦ OPERATION ................................................................................................................ ٥٣ ٦.١ Panel Indications ................................................................................................................................................... ٥٣ ٦.٢ ACTM operation Guidance ................................................................................................................................ ٥٤ ٦.٣ Trouble Shooting .................................................................................................................................................. ٥٤ CHAPTER ٧ ATTACHMENT SMS COMMAND ......................................................................... ٥٦ ٧.١ Introduction ............................................................................................................................................................ ٥٦ ٧.٢ Command format .................................................................................................................................................. ٥٦ ٧.٣ Command list .......................................................................................................................................................... ٥٧ ٧.٤ Command detail .................................................................................................................................................... ٥٧ ٧.٥ Alarm information format ................................................................................................................................ ٦٥

Page 5: Actm usermanual

GPRS/SMS FAM User manual

٥

Chapter ١ Introduction This chapter describes the manual functions and role, also tells the reader how to read the manual, it's best guidance document for install and use Arian GRPS/SMS ACTM.

١. Objective ٢. Application ٣. Version ٤. Convention ٥. Technical Support ٦. Abbreviations

١.١ Objective

This manual mainly ACTM-٩٢٢٠ Quick Start Guide for reference that written to guide ACTM-٩٢٢٠ ACTM installation products.

١.٢ Application

This manual applies to a certain computer communications networks, industrial automation control and electronic technical knowledge, network equipment, administrators, engineers and other industrial control which need to use ACTM-٩٢٢٠ ACTM that relevant managers.

Applies to version: ACTM-٩٢٢٠ ACTM V١.٠ and below versions.

١.٣ Version

According to the market requirement, Arian ACTM-٩٢٢٠ ACTM product-related functions will be adjusted as well as technical improvements. Since the authors have a variety of reasons may cause the contents of revised instructions, the below table show Arian ACTM-٩٢٢٠ product specifications revised at different times and revised version of the reasons for that.

Version Modify department

Participating departments

Date detail

Page 6: Actm usermanual

GPRS/SMS FAM User manual

٦

١.٤ Convention

For ease of use, fast reading manual, we have some short name, icons, description, security alerts, tips and other conventions are as follows:

Convention Description Memo ACTM-922

0 Arian ACTM-9220 GPRS/SMS ACTM

Support ٣ DI, ١ AI, ١ DO ports

ACTM-9220

ET8600 series GPRS/SMS ACTM products

Support ٧ D, 1 AI, ٤ DO ports, Support Wireless Sensor

ACTM GRPS/SMS ACTM

Suggestion Installation time-saving tips or experience

Appear in this manual installation and testing

Notice Prompt the user or reader to pay attention the important information or parameters

Appear in this manual operation

Warning A serious warning, such as the improper use of the temperatures, voltage, unstable environment

Appear in this manual production introduction and installation

Attention General warning: prompt the user some illegal operation or improper use of operations

١.٥ Technical Support

To allow users to quickly solve difficult problems, get the correct solution for hardware, operating system and installation. The following ways to contact Arian

Page 7: Actm usermanual

GPRS/SMS FAM User manual

٧

١.٦ Abbreviations

The Manual related abbreviation meaning:

APN Access Point Name

APP Application

ATM Asynchronous Transfer Mode

ATM Auto Table Machine

AuC Authentication Centre

BG Border Gateway

BGP Border Gateway Protocol

BSC Base Station Controller

BSCC Base Station Control Connection

BSS Base Station System

BSSGP BSS GPRS Protocol

BTS Base Transceiver System

CDMA Code Division Multiple Access

CDR Call Detail Record

CGF Charging Gateway Function

CSD Circuit Switch Data

DDN Digital Data Network

DHCP Dynamic Host Configuration Protocol

DNS Domain Name System

DSC Data Service Center

DTU Data Terminal Unit

EGP External/Exterior Gateway Protocol

EIGRP External/Exterior Internet Group Routing Protocol

EMC Electro Magnetic Compatibility

ESP Electro Static Precautions

ETSI European Telecommunications Standards Institute

GGSN Gateway GPRS Support Node

GMSC Gateway MSC

GPRS General Packet Radio Service

GSM Global System for Mobile Communications

GSN GPRS Support Node

GTP GPRS Tunneling Protocol

GTP-id GTP Identity

ACTM Fixed Asset Monitor

HLR Home Location Register

HSCSD High Speed Circuit Switch Data

Page 8: Actm usermanual

GPRS/SMS FAM User manual

٨

IGMP Internet Group Management Protocol

IGRP Internet Gateway Routing Protocol

IN Intelligent Network

IP Internet Protocol

IPv٤ IP version ٤

IPv٦ IP version ٦

IPSEC IP Secure Protocol

ISDN Integrated Services Digital Network

ISP Internet Service Provider

L٢TP Layer ٢ Tunneling Protocol

LA Location Area

LLC Logical Link Control

MAP Mobile Application Part

MDNS Mobile Domain Name System

MS Mobile Station

MSC Mobile Switching Center

MT Mobile Terminal

MTBF Mean Time between Failures

MTTR Mean Time to Recovery

N/A Not Applicable

NAS Network Access Server

NAT Network Address Translation

NTP Network Time Protocol

O&M Operations & Maintenance

PAP Password Authentication Protocol

PCF Packet Control Function

PDP Packet Data Protocol

PDN Packet Data Network

PDSN Packet Data Service Node

PLMN Public Land Mobile Network

POS Point of Sales

PTM-G Point-to-Multipoint Group Call

PTM-M Point-to-Multipoint Multicast

QoS Quality of Service

RA Routing Area

RADIUS Remote Authentication Dial In User Service

RIP Routing Information Protocol

RSC Register Service Center

RTOS Real Time Operating System

RTP Real-time Transport Protocol

Page 9: Actm usermanual

GPRS/SMS FAM User manual

٩

RTU Remote Terminal Unit

SCADA Supervisory Control and Data Acquisition

SGSN Serving GPRS Support Node

SIM Subscriber Identify Module

SMS Short Message Service

SMSC Short Message Service Center

SNMP Simple Network Management Protocol

STK SIM Tool Kits

TCP Transmission Control Protocol

TDMA Time Division Multiple Access

TMN Telecommunication Managed Network

TTL Time to Live

UDP User Datagram Protocol

UIM User Identify Module

UMTS Universal Mobile Telecommunication System

USSD Unstructured Supplementary Service Data

UTK UIM Tool Kits

VLR Visitor Location Register

WAN Wide Area Network

WAP Wireless Application Protocol

WDDN Wireless Digital Data Network

Page 10: Actm usermanual

GPRS/SMS ACTM User manual

١٠

Chapter 2 Product Introduction This chapter describes the overview of the ACTM system, function and specification, by reading this chapter, the reader can understand the ACTM system configuration, product accessories and detail function.

١. Introduction ٢. System function and feature ٣. Specification

٢.١ Introduction

GPRS network theoretically can provide a maximum bandwidth ١٧١.٢Kbps, actually, it works at ١٠٠~٤٠Kbps bandwidth (it depends on service provider’s operation policy). As we know, GPRS is packet based network which provides TCP/IP communication channel.

GPRS/SMS ACTM (Fixed Asset Monitoring) is an enhanced GPRS/SMS messenger (GPRS or CDMA service optional) which integrated with I/O port, RTU (Remote Terminal Unit), Relay, Sensor functions, it can help people to monitoring, control,SMS alarm the remote devices.

GPRS/SMS ACTM main apllication filed is Home Security, Power grid automatization, industrial monitoring, traffic management, weather, finance, Basic Environmen protecting, colliery, Oil field etc, especially, apply in security, remote control. Implement transparent data transmission over GPRS/SMS network.

The Typical system diagram is as below:

Page 11: Actm usermanual

GPRS/SMS ACTM User manual

١١

٢.١.١ Size ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram, according the different applications, there are mounting holes on both sides to meet the needs of a variety of industrial applications.

ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram, according the different applications, there are mounting holes on both sides to meet the needs of a variety of industrial applications.

Page 12: Actm usermanual

GPRS/SMS ACTM User manual

١٢

٢.١.٢ Accessories In order to protect products during shipment, ACTM-9220 GPRS/SMS ACTM has been packed properly. You may need to keep the packing materials for reshipping after you open the pack box. ACTM-9220 ACTM package includes:

ACTM-9220 ACTM ١ piece (Packed according to P/O) +12V Power adapter ١ piece 2.5 meters antenna ١ piece User manual ١ Piece(CD-ROM) Qualified & Repair Card ١ piece

Optional Accessories:

9Dbi High gain magnet antenna Yagi antenna Fixed antenna Cascading Cable(SMA interface) Configuration and firmware update cable

After you open the box, you should count it carefully with your purchase order.

٢.٢ System function and feature

٢.٢.١ Main function Industrial Design GPRS/SMS ACTM is industrial design which built-in watchdog chipset to ensure the system work continuously, Watchdog monitoring the GPRS module and CPU all the time, if the GPRS module or CPU does not response for long time, ACTM will restart automatically. ACTM is very suitable for long-term continuous work applications.

Support Wireless Sensor ACTM-٩٢٢٠ GPRS / SMS ACTM supports RF wireless sensors, connected through RF٤٣٣.٩٢Mhz frequency with wireless sensors, ٨-way wireless zones, support ٤٠ wireless sensors, and real-time monitoring of the state of the sensor, when the sensor battery is low or disconnect the connection, tamper switch, ACTM will send alarm information.

Transparent data transmission GPRS/SMS ACTM provides full transparent data transmission channel through RS٢٣٢ interface it use for connect different types of PLC, RTU which extend the scope of ACTM application, and better services for users.

Main and backup data center

Page 13: Actm usermanual

GPRS/SMS ACTM User manual

١٣

GPRS/SMS ACTM support main and backup data center, user can set both main data center ip address or domain name, when ACTM fail to connect with main data center, it will try to connect backup data center automatically.

Embedded Li-battery and Temperature sensor GPRS/SMS ACTM built-in ١٠٠٠mA Lithium battery, it can work for ٦ hours if the external power supply cut off. Also, ACTM will send alarm message to notify the user that the external power supply was cut off. the built-in temperature sensor can real-time monitoring of environment temperature, ACTM also support t external digital temperature sensor that monitor user’s device surface temperature, when the temperature lower or higher than the specified value, ACTM will send alarm message, when the temperature returned to normal, ACTM will send notice message to user also.

User-define alarm SMS GPRS/SMS ACTM support User-define alarm SMS, according to alarm port status, ACTM will choose the user pre-define content, and send to user mobile phone by SMS, it’s easy for user to understand alarm message.

I/O status Buffer ACTM has NVRAM buffer to save the I/O status data during GPRS/SMS tunnel problem, when the GPRS/SMS tunnel return to normal, ACTM will send buffer all data immediately, NVRAM has feature for save data even power lose, so even ACTM power lose, the buffer data will still save.

Ring and SMS alarm ACTM support ring and SMS for sending alarm message, when the alarm occurred, ACTM will start ring for ١٠ seconds, and then send alarm SMS to users. Users also can remote setting and control ACTM by SMS.

SMS receipt To ensure user receive the alarm messages, user can set the alarm SMS resend frequency, unless the alarm clear or receive ACK message receipt from user phone, ACTM will repeat to send alarm SMS by Specified frequency and interval.

Alarm clear message All of ACTM I/O port can be set the alarm clear message, when the port alarm status clear, ACTM will send alarm clear SMS to notice user.

Regularly report the I/O status ACTM-٩٢٢٠ ACTM support auto send I/O port status by specified time, after user set the time, ACTM will send the port status on specified time daily.

DO port programmable output ACTM DO (digital output) port supports programmable output, according to the requirement of user site, the level of output level, switching time, times would be programmable.

Zone type ACTM DI ports support zone type setting which can be set to as common zone, delay zone, intelligent zone, emergency zone, home zone, according to the user site conditions and sensor type, set the correct zone type to prevent false alarm, missing alarm.

GPRS SMS work at the same time

Page 14: Actm usermanual

GPRS/SMS ACTM User manual

١٤

ACTM communication through GPRS to data center, at the same time, ACTM also can occur SMS to the user's mobile phone, so that’s insuring the user receive the alarm message via GPRS and SMS.

Timing arm/disarm, password arm/disarm ACTM support timing arm/disarm function, it can perform a specified time every day to arm/disarm; ACTM also support any mobile phone number via a password to arm/disarm, after the instruction is executed successfully, ACTM will arm/disarm information to the administrator phone as well.

Camera capture picture ACTM provides the interface to connect with camera, real-time remote image capture, with the ACTM IO ports, real-time capture images when an alarm is generated, and sent to the data center; ACTM can be set to a fixed time interval for continuous capture images as well.

MODBUS Protocol programmable output ACTM provides storage and forwarding the command functions of the MODBUS protocol, users can pre-save the common command to ACTM, and ACTM will send the command PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically.

Clock synchronization ACTM support clock synchronization; it can read the clock from SMS or get clock from management platform by GPRS.

Cell phone and PC be Data service center GPRS/SMS ACTM supports cell phone and PC server to be data service center, if PC to be service center, please use Arian ACTM management platform software, it supports SQL data base, Google map etc. it can monitor thousands ACTM via GPRS; if the stations exceeds ٥٠٠ points, we suggest use ACTM management platform.

Graphical configuration software ACTM-٩٢٢٠ GPRS/SMS ACTM provide full graphical software configuration, easy to use, and supports import or export configuration file; so users just simply click a few icons to quickly setup ACTM system.

Worldwide applications GPRS/SMS ACTM has broad range of applications; it can be used in industrial remote monitor, security, meteorology, environmental protection, water conservancy, electric power industries. To more suitable of industrial M٢M applications, Arian can quickly modify the software and hardware according to customer requirements.

٢.٢.٢ Part of compatible sensor The below item is part of ACTM compatible sensors: Float Water Level Sensor Pressure Sensor Speed Sensor Infrared Detector

Temperature SensorMagnetism Detector Flow Sensor Shock Sensor

Wind Sensor Smoke Sensor Lighting Sensor Gas/LPG Detector

Page 15: Actm usermanual

GPRS/SMS ACTM User manual

١٥

Humidity Sensor Dynamo Sensor Water immersion Sensor

RelayMicrowave Motion Sensor Voltage Sensor

Horizontal Sensor Emergency Button Sound & Flash Siren

٢.٣ Specification

Basic

GPRS Dual Bands ٩٠٠Mhz/ ١٨٠٠Mhz GPRS Quad Bands ٨٥٠/٩٠٠/١٨٠٠/١٩٠٠Mhz (Optional) CDMA ٨٠٠mhz (Optional) Dual SIM Slot (Optional) Self-define re-connecting interval Clock synchronizing Support external temperature sensor Embedded Temperature Sensor Support Temperature verify I/O status buffer Self-define report I/O status daily Self-define online report interval AI and the TE port upper and lower limits DO port programmable output DI port zone type setting Timing, password arm/disarm GPRS SMS work at the same time MODBUS Protocol programmable output Optical isolation terminal Smart power management Automatic power supply detection Li-Battery inside (Optional) Support ٢ DI pulse input (Optional) Support GPS (Optional) Support Max ١٦ Temperature sensors (Optional) Support camera to Photograph Support alarm link to photograph PC based configuration tool Real time OS, steady system Watch dog design, ensure ACTM alive Low consumption, industrial design Fully type approved with ETSI GSM Phase ٢+ standard Enhanced EMC/EMI design

GPRS

Industrial class GPRS wireless module Embedded PPP, TCP/IP Stack Support main and backup service center Support TCP/IP and UDP/IP Transparent data transmission Support RS٢٣٢ interface for data transmission

Page 16: Actm usermanual

GPRS/SMS ACTM User manual

١٦

Supports DNS and dynamic data service center IP address Support continually or sleep work mode Support Carrier public & special APN Work with ACTM management platform Remote monitoring and control

SMS

Support SMS and Ring Alarm Set defense by SMS Self-define SMS alarm message Alarm/Disarm by SMS Automatic send alarm SMS to mobile phone when alarm is triggered Support ٤ service center number, and customized setting for center SMS query ACTM signal strength DO Relay triggered by alarm or SMS Automatic SMS alarm when data above or below the preset levels Support SMS remote configuration Alarm clear message Alarm SMS receipt and acknowledgement

RF Wireless

Frequency: ٤٣٣.٩٢Mhz Wireless transmission distance: ١٠٠meter standard environment Support sensor low battery alarm Support sensor Tamper alarm Support sensor disconnect alarm Real-time monitoring of sensor status Anti-RF interference ٨ wireless zones Supports ٤٠ wireless sensor Support ٥ remoter Support wireless zone type setting

Interface

Antenna: ٥٠Ω/SMA Female SIM/R-UIM: ٣V Configuration: RS٢٣٢ Data: RS٢٣٢ (RS٤٨٥, Ethernet Optional) DI: ٣ Ports (٣-٠V False, ٣٦-٣V True) AI: ١ Port DO: ١ Port TE: ٢ ports

Note: DI = Digital Input AI = Analog Input DO = Digital Output TE = Temperature

Power

Voltage: ١٢V~١٨VDC (٣٠~١٢V Optional)

Page 17: Actm usermanual

GPRS/SMS ACTM User manual

١٧

Default Voltage: DC١٢V Consumption:

Communication: ١٢٠mA@+١٢VDC Idle: ٣٠mA@+١٢VDC

Others

Dimension: ٩٠mmx٦٢mmx٢٢.٥mm Weight: ١٩٠g Operation temperature: -٧٥+~٤٥ºC Storage temperature: -٨٥+~٥٥ºC Relative humidity: ٩٥% (no-condensing)

Page 18: Actm usermanual

GPRS/SMS ACTM User manual

١٨

Chapter 3 Installation This chapter describes in detail about ACTM system hardware installation, cable and sensor connections, by reading this chapter, the reader should be able to complete the ACTM hardware installation.

١. ACTM installation and cable connection ٢. Sensors installation ٣. Grounding ٤. Power supply ٥. Check the mobile network

٣.١ ACTM installation and cable connection

GPRS/SMS ACTM should be installed and configured properly before putting it in service. The installation and configuration should be done or supervised by Arian qualified engineer.

Attention: Do not install GPRS/SMS ACTM or connect/disconnect its cable when it is power on.

3.1.١ Antenna and SIM card installation Using the antenna or other sharp items to click the top of the yellow dots SIM card connector, SIM card slot will automatically pop up, please put SIM card into the slot, and push the SIM card connector to the slot. The picture shown is as below:

3.١.٢ RS232 configuration and Power cables installation ACTM-9220 ACTM signals and power supply is connected by industrial class pluggable terminals, ٣.81mm, ١٢Pin, and ٢٤~١٤AWG outlet cable is recommended. Each line definition refers to the following diagrams and tables. Also, you can find outlet cable definition table at top of ACTM-9220 ACTM cover. As shown in the following diagrams and tables, peel off the cable end about ٧mm and connect each terminal and cable (٢٤~١٤AWG cable recommended. Make sure that you have connected the terminals without any mistake.

Page 19: Actm usermanual

GPRS/SMS ACTM User manual

١٩

PIN Signal name Description MEMO Vin +5~18V Power Vin, recommend

12V 80mA@12V

GND GND Power GND Vout Power Output This PIN voltage

is same Vin DI1 Digital Input 1 Voltage range: 0-36V DI2 Digital Input 2 Voltage range: 0-36V DI3 Digital Input 3 Voltage range: 0-36V GND GND Signal GND; common with

user’s device; RS232 GND

AI1 Analog Input 1 Voltage range: 0-10V DO1 Digital output 1 Default is low level This PIN voltage

is same Vin TX Send data RS232 TX RX Receive data RS232 RX UG Software Upgrade After connect with GND,

ACTM will enter to software upgrade status

Attention: The power cable should be connected correctly. We suggest double check before switch it on. Wrong connections may destroy the equipment. Power terminals: Pin ١ and Pin ٢; Here: Pin ١ is Power input “Vin” (+١٨+~٥VDC), Pin ٢ is”GND”.

٣.٢ Sensors installation

ACTM-9220 ACTM Provides 3 DI ports ,1 AI port,1 DO port. The sensors installation is as below:

٧mm

14~24AWG

٧mm٧mm

14~24AWG

Page 20: Actm usermanual

GPRS/SMS ACTM User manual

٢٠

3.2.1 DI (Digital Input) sensor installation DI sensor only two states, high level (٣٦-٣V) and low level (٣-٠V). There are ٢ kinds of DI sensors, switching and voltage type. Switch DI Sensor The switching DI sensor is like a simple switch, it only has ٢ statuses, ON or OFF. Connect the switch sensor ٢ signal lines to ACTM Vout pin and DI pins. it can be connected to multiple sensors; the common switching DI sensor such as Magnetic sensor, float level sensors, infrared sensors, pressure sensors, gas sensors, emergency buttons etc. the connections diagram as shown below:

To achieve the alarm linkage, alarm equipment and DI port can be parallel interfaces to achieve the alarm linkage. When Magnetic sensors have closed, the sound and light alarm simultaneously closed, as follows picture:

Voltage DI Sensor The Voltage DI sensor provide DC voltage, connect the sensor Pin+ to ACTM DI pin, GND

to ACTM GND, the common voltage DI sensor such as water immersion sensor, the connection diagram as shown below:

Page 21: Actm usermanual

GPRS/SMS ACTM User manual

٢١

3.2.2 AI (Analog Input) Sensor installation Voltage AI Sensor Voltage sensor provide a voltage to the ACTM AI ports that required voltage between ١٠-٠V, connect sensor Vout to the ACTM AI pin, GND connect to ACTM GND, the commonly used voltage AI sensor such as current sensor , Voltage sensor, fuel sensor etc. shown as follows:

resistance AI sensor Resistance AI sensor is like a variable resistor, such as resistance Humidity sensors, ١٠kΩ is the standard resistance; its resistance to humidity changes as the actual changing. Connect the sensor 2Pin to the ACTM AI and Vout pin. The commonly resistance AI sensor such as humidity sensor and so on.

3.2.3 DO (Digital Output) device installation ACTM DO port provides the same voltage a Vin pin, and not more than ٢٠٠mA of current output. DO port can be used to control remote devices such as relays, photoelectric alarm, and alarm speakers. The installation diagram showed as below:

Page 22: Actm usermanual

GPRS/SMS ACTM User manual

٢٢

Attention: When the external power supply disconnect, ACTM will using internal battery power, the internal lithium battery supply voltage as ٣.٧V, so the DO port cannot provide ١٢V voltage, only output 3.7V voltage, so DO port will unfunctional. DO port provides maximum ٢٠٠mA output current, if use DO port to control equipment which more than ٢٠٠mA current, it should be added relay between ACTM and equipment.

3.2.4 TE (Temperature) sensor installation ACTM provides two TE ports, TE٢ is the built-in NTC thermistor, the user can directly use it without installation; TE٢ is an external digital temperature interface, the digital temperature sensor connect to TE٢ port, it can be use for monitor equipment surface temperature, ambient temperature, water temperature, oil temperature and so on. The installation diagram showed as below:

3.2.5 Wireless Sensor installation ACTM supports wireless sensors, wireless sensor using ٤٣٣MHZ RF to connect with ACTM controller, just assembled wireless sensor battery, and then through ACTM configuration tool to registered wireless sensor, the sensor would be connect to ACTM successfully.

3.2.6 Camera installation ACTM supports camera capture picture function, camera connect to ACTM via RS232 port, DC 12V Power, the installation diagram showed as below:

Page 23: Actm usermanual

GPRS/SMS ACTM User manual

٢٣

Please connect camera cable to ACTM according to the above figure cable color: Camera ACTM Green ----> RX Yellow ----> TX Black ----> GND Red ---- > Vout After finish the ACTM and camera cable connection, we need to complete the implementation of the following actions: Turn OFF the debug information display on the configuration software Turn ON the camera function on the configuration software Disconnect the ACTM configuration cable to PC (ACTM mini-USB side) Restart ACTM

Notice: ACTM and the camera both is connected via the RS٢٣٢ interface, the camera can not be used when the ACTM at configuration status. ACTM configuration cable must be disconnecting, and then the camera should be work properly.

3.2.7 RTU device installation ACTM provides RS٢٣٢ interface to connect other RTU device; it’s a three-line, installation diagram shown as below:

Page 24: Actm usermanual

GPRS/SMS ACTM User manual

٢٤

٣.٣ Grounding

To ensure a safe, stable and reliable ACTM-9220 GPRS/SMS ACTM operation, the ACTM cabinet should be grounded properly. Connect the ACTM cabinet to site ground wire at the ground point

٣.٤ Power supply

ACTM-9220 ACTM is designed with advanced power management technologies; it can operate standalone. The DC power is supplied via pluggable terminal Pin ١ (Vin) and Pin ٢ (GND). Detail definitions refer to above tables.

Notice: About Power Supply: When ACTM-9220 GPRS/SMS ACTM communicates with base station, surge current will exceed normal current. Therefore, margins ٥ times over normal current may be required for external power supply. Normally, ACTM-9220 ACTM input power supply is +٥~+18VDC, in most cases, ١٢VDC/١A is recommended. Power supply ripple should be less ٣٠٠ mV.

٣.٥ Check the mobile network

Connect all signal and power cables, and double check it, connect antenna, insert a valid SIM and switch on power. ACTM-9220 “PWR” LED will light up. After around 30 seconds, If “NET” and “DATA” LED is flashing at same time (ON for 2 seconds then OFF for 2 seconds), it means the ACTM-9220 ACTM is working normally. If the “DATA” LED is flashing, it means there are data stream. If the “NET” LED lights up, it means that the ACTM-9220 ACTM has found and logged on mobile network.

Page 25: Actm usermanual

GPRS/SMS ACTM User manual

٢٥

Warning: All cables should be connected correctly before switch on. Antenna should be connected before switch on, otherwise it may cause radio module problem

Page 26: Actm usermanual

GPRS/SMS ACTM User manual

٢٦

Chapter 4 Terminal Configuration This chapter describes in detail about ACTM configuration software, by reading this chapter, the reader should be able to know the function of ACTM, and change the configuration according actual requirement.

١. Device Connection ٢. Parameter Configuration ٣. Parameter Detail

٤.١ Device Connection

ACTM graphical configuration software, it's easy to use and operation. Before the formal operation on the device, ACTM-٩٢٢٠ ACTM must be set to correct parameters. ACTM supports two ways to communication with PC.

Notice: ACTM provide power switch (close the green socket), turn the power switch to the ON, ACTM will power ON and start run.

By using Arian configuration cable connect to ACTM Console port, which has upgraded

firmware button (Blue Button) on the cable, when press in the button, ACTM will enter to firmware upgrade mode, and all of 4 LED will be ON; when press out the button, ACTM will enter to normal work mode, the Power LED will be ON, Data LED will be flash. the connection diagram shown as Below:

Page 27: Actm usermanual

GPRS/SMS ACTM User manual

٢٧

Connect PC's RS٢٣٢ interface to the ACTM terminals RX, TX, GND pin, if Connect

ACTM terminal UG and GND pin together, ACTM will enter the software upgrade status. the connection diagram shown as Below:

Page 28: Actm usermanual

GPRS/SMS ACTM User manual

٢٨

٤.٢ Parameter Configuration

A. Connect ACTM According the above two ways to connected PC and ACTM, and installed ACTM configuration software on the PC. Switch ON ACTM power, start ACTM configuration software on the PC, click the interface in the navigation bar of the "OPEN “button, if the connection is successful, the software will automatically connect with the ACTM, and ACTM read all configuration information. If the connection is not successful, click on the navigation bar "PORT" button, select the correct port number, baud rate is ١١٥٢٠٠, and then click "OPEN" to retry the connection. When the information bar shows "Login Successful", it means that the configuration software and ACTM-٩٢٢٠ ACTM connection is successful, the picture shown as follows:

Page 29: Actm usermanual

GPRS/SMS ACTM User manual

٢٩

Attention: After Configuration software connected ACTM successful, it will read ACTM configuration information and refresh automatically, this process may takes about ٢٠ seconds, and will slightly pause is normal. Using the configuration software, please turn OFF the ACTM debugging information, the debug information will affect the configuration software to read the ACTM information. When the SIM card is not inserted, or ACTM in the TCP / UDP mode, if the GPRS connection is not successful that ACTM will automatically restart, and then configure software will appear that failure to read/set parameters, just simply click "Connect" button on the navigation bar, ACTM will connect again.

B. Query Parameter For query ACTM parameters, just click the optional checkbox in the left window (multiple choice), then click the navigation bar "Query" button, the configuration software will query the ACTM parameter information, and refresh the option box.

Notice: if didn't tick any parameter options box, and click on "Query" button, ACTM will returns the current status values of all the IO ports in the information bar, this feature is easy to test sensor, and real-time query IO port status.

C. Set Parameter To change the ACTM parameters, just click the optional checkbox in the left window (multiple choices), then modify the parameter value detail, and click the navigation bar "Save" button, the configuration software will save the parameter information to the

Page 30: Actm usermanual

GPRS/SMS ACTM User manual

٣٠

ACTM, if save successful, it will show "the parameter have been save successful" in the message window ", the picture shown as below:

Notice: If didn't tick any parameter options box, and click on "Save" button, ACTM will implement save command. After registrater the wireless sensor, you need by clicking on the "Save" button to execute the save.

D. Series Port Configuration Click the navigation bar "Port" button to open the serial port configuration window, it need to select the appropriate connection port and the baud rate to connect to ACTM, the picture shown as below:

Notice: The default login password is ٠٠٠٠٠٠, please do not change this password if it's not necessary; once change the parameter on the configuration page, you should also change the same login password here, otherwise ACTM will not able to login.

Page 31: Actm usermanual

GPRS/SMS ACTM User manual

٣١

E. Series Port Window The serial window is for testing and troubleshoots, click on the navigation bar "serial window" button, the window from the parameter window into the serial port window, for return parameter window, and just click "parameter window" button on the navigation bar.

Attention: Send commands to the ACTM in the serial port window may bring unexpected problems; usually, please do not enter to the serial port window mode.

F. Common Parameter Click the navigation bar "Common setting" button to open the common parameter settings window, you can select the frequency parameter to the common parameters window, and it’s for mass and quickly configuration ACTM. the picture shown as Below:

G. All Click the navigation bar "All" button, it will select all option on the Parameter Configuration page, that’s easy for user to operation. H. Clock Synchronization Click the navigation bar "Clock Synchronization" button, ACTMcfg software will ready the computer clock information, and write to ACTM.

Notice: ACTM supports three way to clock synchronization: configuration software, SMS, Data center via GPRS; by the configuration software and SMS clock synchronization, when ACTM power lose, the clock will automatically be zero, and need to clock synchronization again; by the GPRS mode, ACTM will clock synchronization by each login data center, we recommend using GPRS for clock synchronization.

Page 32: Actm usermanual

GPRS/SMS ACTM User manual

٣٢

I. Restart Click the navigation bar "restart "button, ACTM will immediately restart, and show "restart the device successful "in the information bar, about ١٠ seconds, click the "Connect" button , software will try to connect ACTM again. J. Default Parameter Click the navigation bar "Default “button, ACTM will revert all parameters to the default.

Attention: This operation will restore ACTM parameters to factory state, it need to re-set ACTM parameters in order for ACTM to work again.

K. Import/Export Import / export feature is mainly used for quickly and easy to mass ACTMs, click the menu bar "File “option under the "Export ", you can export the current configuration to be INI file. Click menu bar "File “option under the "Import ", then select the INI file which saved before, you can import the original configuration files in the current software

Suggestion: "Import / Export" function can be used with the "Common Parameters” together, after the import parameters, click "Common Setting" and "All" button, then click “Save" button, this way will quickly save all of parameter you need. Attention: During "Import / Export “parameter, due to software will read/write large data, software may pause a few seconds, its normal.

٤.٣ Parameter Detail

A. SIM Para. Click the left mouse button on "SIM Para."; enter to the SIM card parameter setting, the picture shown as below:

Page 33: Actm usermanual

GPRS/SMS ACTM User manual

٣٣

APN Name (APN) Follow the prompts to enter information into the access point name (access point name cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" button on the navigation bar ", the message bar will show "parameters set successfully".

Attention: Access Point Name (APN) is mobile operator to provide users with different access network types; you must query the APN name from the local operator, and then modify the APN name on the ACTM, so ACTM will able to connect to local GPRS network.

Username Login GPRS service username, usually empty Password Login GPRS service password, usually empty B. RTU Connection Setting Click the left mouse button on "RTU Setting"; enter to the RTU connection setting, the picture shown as below:

Page 34: Actm usermanual

GPRS/SMS ACTM User manual

٣٤

Band Serial port configuration, selectable baud rate is ١١٥٢٠٠-٣٠٠.

Attention: This band is same band with configuration software connect to ACTM, if you modify this band rate, simultaneously modify configuration band, then the configuration software able to connect the ACTM.

Data bit Serial port configuration, data bits is ٨-bit usually Stop bit Serial port configuration, usually is ١ stop bit Parity bit Serial port configuration, parity bit is NONE usually Data packet interval ٢٠٠٠-١٠٠ms, RTU Packet Minimum time interval, the default is 300ms Customized RTU Command ACTM can end command to RTU automatically, command is hex code, no space between commands, for example: the command is ٢٣ ٠٠ ٠١ ٠٠ ٤٥ ٥٥, so just fill in as ٥٥٤٥٠٠٠١٠٠٢٣ Data Header Add data head on sending RTU data to center; Format: ID(Max ١٦ byte ASCII code)@time,date(٦ byte, HEX format)@ data (hex code) Command Interval Interval for sending RTU commands within group Group commands Interval Interval for sending RTU commands between groups SMS RTU At the SMS mode, ACTM can forward RTU data via SMS to the data center and pass-through SMS data from data center to the RTU seires port C. IP Channel Setting

Page 35: Actm usermanual

GPRS/SMS ACTM User manual

٣٥

The Parameter is for ACTM work on TCP/UDP mode; click the left mouse on"IP Channel"; enter to the IP parameter setting, the picture shown as below:

Main IP address x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center through domain name. Main Domain Name Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center. Main Port ٦٥٥٣٥-١, Main data center IP port Backup IP address x.x.x.x, Backup data center IP address. if ACTM cannot connect to main IP address many times, ACTM will try to connect backup IP address. Backup Domain Name Backup data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center. Backup Port ٦٥٥٣٥-١, Backup Data center IP port. Heartbeat Interval ٦٥٥٣٥-٠ Seconds, Heartbeat interval, if value is 0, ACTM will don’t send heartbeat data. The default interval is 40 seconds. The heartbeat is link maintain parameter, that is the heartbeat interval, ACTM periodically sends the fixed format of heartbeat packets to data center, which has maintained a link connection. This is because the network operators in order to prevent terminals linked to the Internet, but don't transferring data, taking the wireless network resources, as found in the terminal does not transmit data within a certain period of time, it will kick off the assembly line to the terminal. Work mode

Page 36: Actm usermanual

GPRS/SMS ACTM User manual

٣٦

GPRS transmission work mode, IO protocol mode will send&receive data through Arian protocol, and it use for connect ACTM management platform; transparent mode, using the transparent data channel, and sends heartbeat packets, it’s for connect to other platform or data center. Sleep Mode For save GPRS data transmission, ACTM provide 2 kinds of online solution; always online, ACTM will online GPRS all the time; Sleep mode, ACTM will wait for specified time, if there is no alarm and no data transmission, GPRS will automatically be offline, however, it can be activated by SMS or ring Offline interval ٦٥٥٣٥-٠ Seconds, ACTM offline waiting time, the default is 300 seconds. Reconnection Interval ٦٥٥٣٥-٠Seconds, IP channel failure or reconnect after sleep time interval, if set to ٠, ACTM will don't try re-connect, only wake-up can make ACTM on-line, the default value is 300 seconds. A group of the number of re-connect 一Set to ٠, no change to backup channel, only try to connect the main channel A group of reconnection interval 一A group of reconnection interval, Seconds Two groups of reconnection interval Two groups of reconnection interval, Minute!!! The default is 10 minutes. Login attempt times Set as ٠, ACTM only send a registration packet once, Data center is not neccessary to reply registration ACK package; ١ to ١٠, Data centers must respond to the registration ACK package, otherwisem, ACTM will disconnect and reconnect Heartbeat ACK According to the GPRS signal unstab area, we can enable the heartbeat ACK function. If ACTM did not receive heartbeat ACK packets from data center as ٣ times, ACTM will disconnect the link and try to reconnect. SMS Backup For the GPRS network often abnormal area, we can enable SMS backup function, when the GPRS link is disconnect, ACTM will also send a message via SMS to the data center; When GPRS recovery, ACTM will send this information to the data center again. D. SMS Channel Setting The parameter is for ACTM work on SMS mode, click the left mouse button on "SMS Channel "; enter to the SMS Channel parameter setting, the picture shown as below:

Page 37: Actm usermanual

GPRS/SMS ACTM User manual

٣٧

Service Number For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please add country code on the front, the number is for receive alarm SMS from ACTM, and remote control ACTM through SMS. Service Number Mode The Service number supports 4 modes: Alarm mode, this number only receive alarm SMS, but it can not using SMS for remote settings ACTM. Alarm+Config mode, ACTM send alarm SMS to this number, the number can be remote control ACTM as well. Config mode, this number only for remote config ACTM, it cannot receive alarm SMS. Administrator mode: This number supports Alarm + SMS all functionality, and receive all arm and disarm information via SMS. Daily report ٢٣:٥٩-٠٠:٠٠, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable. Report at specified intervals ٢٣:٥٩-٠٠:٠٠, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable Alarm Mode For real time inform user about alarm, ACTM support 3 kinds of alarm mode. SMS mode, ACTM only send alarm SMS; Ring mode, ACTM only Ring; SMS+Ring mode, ACTM will ring for ٦٠ seconds, then send alarm SMS. SMS Alarm Content For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the alarm happen, ACTM will send the pre-set SMS to service number. customize mode, ACTM will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send alarm SMS according Arian protocol E. I/O Port Setting The parameter is for ACTM I/O port setting, click the left mouse button on "I/O port setting"; enter to the I/O parameter setting, the picture shown as below:

Page 38: Actm usermanual

GPRS/SMS ACTM User manual

٣٨

Attention: Configuration software can set ACTM-9220 and ACTM-9220 product parameter, ACTM-9220 provide 3 DI, 1 AI, 1 DO, 2 TE ports, ACTM-9220 provide 7 DI, 4 AI, 4DO, 2 TE Ports. When set the ACTM-9220 I/O ports, just disable port alarm for DI4, DI5, DI6, DI7, AI, 2, AI3 etc. if enable the not exist port alarm, there may be some illegal value, the false alarms may happen.

DI Alarm Status Low level, when port is low level, alarm happen; High level, when port is high level, alarm happen; Status change, when the port status change, alarm happen; Pluse input, if connect to pluse input device, choose this option; The default is Disable alarm. DI Zone Type Normal Zone: Start detect after arm immediately. Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for PIR montion sensor, in case the wrong alarm.

Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for connect to emergency button, smoke sensor etc.

Home Zone: This zone can be turning off by Home button of remote controller; when user at home, he can use this function for disable some sensor inside home. DI Zone Type Normal Zone: Start detect after arm immediately. Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for PIR montion sensor, in case the wrong alarm. DI trigger duration

Page 39: Actm usermanual

GPRS/SMS ACTM User manual

٣٩

Unit: ١٠٠ms, default value is ٢, so the duration is ٢٠٠ms. When DI port achieves alarm value, and keeps after specified duration, occur alarm. According to part of senors (such as float level sensors, pressure sensors), the value may be hovering between alarm/normal, it may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set DI port trigger duration, if DI port at alarm state and exceeds specified duration, then ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes. DI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, tower water level is low! DI Alarm Clear Customize SMS The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning, tower water level return to normal!

Attention: All customize SMS content can not include a comma, the comma as a parameter separator that can not be used as a custom SMS content, we have to use other symbols instead of comma.

WI Zone Type Close Zone: Close this wireless zone. Normal Zone: Start detect after arm immediately. Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for PIR montion sensor, in case the wrong alarm.

Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for connect to emergency button, smoke sensor etc.

Home Zone: This zone can be turning off by Home button of remote controller; when user at home, he can use this function for disable some sensor inside home. WI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, detect people come in!

Notice: Here is set wireless sensor WI zone types and customize SMS content, for using a wireless sensor, you must first register wireless sensors, according the wireless sensor registration, please refer to the "Wireless parameter setting".

Wireless sensor online detect period The Default value is OFF detect function; all of Arian wireless sensor/detector products support online detection function, the sensor sends online informatoin to ACTM about every ٣ hours, ACTM recieve online information that means sensor is online; if ACTM didn't received sensor online information for long time that means sensor already disconnect, ACTM will occur sensor disconnect alarm. The detection time can be set to ٢٤ ,١٦ ,٨ to ٩٦ hours, in order to avoid false alarms, we can choose the appropriate online detection period or OFF detection function. AI Alarm Status This is AI port Upper&Lower voltage value, ٣٣٠ is ٣.٣V, For example: ٢١٠~١٠٠, when AI port voltage Lower than ١V, lower limit alarm happen; when higher than ٢.١V, Upper limit alarm. Value is 0~0 is disable AI port alarm.

Page 40: Actm usermanual

GPRS/SMS ACTM User manual

٤٠

Notice: To prevent fluctuations in the value of AI interfaces to occur repeated alarm, when the AI interface value beyond the scope of the directive over the value of +10, ACTM will occur alarm, when the AI interface value back to the normal range -10, ACTM will occur alarm clear. This value can be set through”AI Port alarm Accuracy”. For example: set value as 100~210, so when the AI port value to be 90 or 220, ACTM will occur alarm, when the temperature return to 110 or 200, ACTM will occur alarm clear.

AI trigger duration Unit: ١٠٠ms, default value is 1, so the duration is 1٠٠ms. When AI port achieves alarm value, and keeps after specified duration, occur alarm. According to part of senors (such as voltage sensors, current sensors), the value may be hovering between alarm/normal, it may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set AI port trigger duration, if AI port at alarm state and exceeds specified duration, then ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes. AI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, water pressure exceeds the limit! AI Alarm Clear Customize SMS The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning, water pressure return to normal! AI Port alarm Accuracy The current value is greater than or lower than the set alarm value and more than the accuracy value, alarm hapeen. TE Temperature Alarm Status This value is the temperature of the upper and lower limits, the units is . For example: -5~28, when the temperature is lower than -5 or higher than 28, the alarm will occur; When the temperature returned to normal, the alarm clear will occur. 0~0 is disable TE port alarm.

Notice: To prevent fluctuations in the value of TE temperature to occur repeated alarm, when the temperature value beyond the scope of the directive over the value of +1, ACTM will occur alarm, when the AI interface value back to the normal range -1, ACTM will occur alarm clear. For example: set value as -5~28, so when the temperature to be -6 or 29, ACTM will occur alarm, when the temperature return to -4 or 27, ACTM will occur alarm clear.

TE trigger duration Unit: ١s, default value is 1, so the duration is 1 second. When TE port temperature achieves alarm value, and keeps after specified duration, ACTM will occur alarm. According to temperature value may be hovering between alarm/normal, it may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set TE port trigger duration, if TE port at alarm state and exceeds specified duration, then ACTM will occur alarm. For example: the trigger duration set to ٣٠٠, so that's ٥ minutes. TE Temperature Alarm Customize SMS The string length is not longer than 40, when the alarm occurs; send this alarm message content to the service number. For example: Warning temperature is too low! TE Temperature Alarm Clear Customize SMS

Page 41: Actm usermanual

GPRS/SMS ACTM User manual

٤١

The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning clear, temperature return to normal!

Attention: ACTM provides two kinds of temperature, TE1 is external digital temperature interface, it connects to extend temperature sensor, high accuracy. TE2 is embedded NTC temperature sensor, it’s for test environment and ACTM device temperature.

DO Output Control DO output, When DO output mode as High or Low level mode, choose high or low level the default is low level; the DO port output voltage is same as Vin PIN voltage.; When the DO output mode as programming mode, choose the high level to trigger the implementation of the programmatic output, after the implementation returns an unavailable level. DO Output Mode ACTM DO port support 2 mode, High or Low Level Mode,output as High or Low Level simply; Program Modem,output as programming level DO Output Program Example: 1,1,2,3,2,00:00:00; 1 is Port;1 is avaiable level,high or low; 2 is available level time period (Second); ٣ is unavailable level time period (Second); ٢ is cycle times; ٠٠:٠٠:٠٠ not implement as daily

Notice: ACTM DO (digital output) port supports programmable output, according to the requirement of user site, the level of output level, switching time, times would be programmable. Please contact Arian technical engineer for instruction detail.

DO output link alarm When alarm trigger, link to DO output. DO Output Link Program DO output the alarm link trigger port, type in the port name DI,TE,AI,WI (DI behalf of all DI port, DI١ specifically DI١ port only) DO Smart Link For example: ٢ ;٢,٦٠ times the specified port alarm within ٦٠ seconds, DO trigger output Power Status Detect Detect external power status, if the external power disconnect, ACTM will send alarm SMS to service number. The default is ON. Alarm Clear Message Set as ON, if detect port alarm clear, ACTM will send alarm clear message. F. Wireless Parameter Setting The parameter is for register wireless sensor, click the left mouse button on "Wireless"; enter to the Wireless parameter setting, the picture shown as below:

Page 42: Actm usermanual

GPRS/SMS ACTM User manual

٤٢

Notice: All wireless sensors must be registered on use wireless zones of the ACTM, and then it can be used.

Wireless Zone Zone: WI١ to WI٨ zones, each zone can be registered ٥ wireless sensors. Registrater: wireless sensor registerion, after choose the zone, click "Register", ACTM into the registration status, the information bar will prompt: Registratring ..., you need to take the wireless sensor to send an alarm signal (through Tamper button or alarm), when ACTM received this signal, you will heard "TA", it means sensor register successful. Cancel: click "Cancel" to cancel the current registration. Delete: select zone, then click "delete", it will delete the entire sensor on specified wireless zones. Delete All: click "Delete all", it will delete all wireless sensor from all zones. Remoter Function: Arm, Disarm, Home button; total 3 remoter buttons, each button can be registerd for 5 remoter, it means each ACTM support max 5 remoter. Registrater: after choose the function button; click "Register", ACTM into the registration status, the information bar will prompt: Registratring ..., you need to push the button the remoter, and you will hear "TA" from ACTM, it means register successful. Cancel: click "Cancel" to cancel the current registration. Delete: select function button, then click "delete", it will delete the entire funmciton button of all remoter. Delete All: click "Delete all", it will delete all remoter on the all function buttons.

Notice: Wireless sensor support tamper switch, low battery, link disconnect alarm, when ACTM disconnect link with sensors more than ١٦ hours, the disconnect sensor alarm will happen.

Page 43: Actm usermanual

GPRS/SMS ACTM User manual

٤٣

After click the "Register" button, ACTM must receive the sensor signal within ٣ minutes; otherwise, ACTM will exit from register status.

G. LED Screen Parameter Setting At the SMS Mode, ACTM can connect an LED Screen, the parameter is for LED Screen setting, , click the left mouse button on "LED Para."; enter to the LED parameter setting, the picture shown as below:

LED Screen At SMS mode, whether turn ON the LED screen function, when an alarm is occured, ACTM will send the alarm customize SMS content to the LED screen. if ACTM didn't connect with LED screen, turn OFFthis function.

Attention: At GPRS communication mode, this option should be turned off. Data center platform will control the LED display via GPRS directly, it don't need ACTM to control.

Window Number Send alarm information to the specified window number of LED screen Display Time Alarm information display time period, ٠ to ٦٥٥٣٥ seconds, value ٠ is always show Effects coding Alarm information display effects coding Alignment Alarm information display Alignment Display Speed Alarm information display speed, from ٠ to ١٠٠, the smaller the value are more faster Stay time Alarm information display stay time Font color

Page 44: Actm usermanual

GPRS/SMS ACTM User manual

٤٤

Alarm information display font color Font Size Alarm information display font size H. Run Setting The parameter is for ACTM run setting, click the left mouse button on "Run Setting"; enter to the Run parameter setting, the picture shown as below:

ACTM ID Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be location name, owner name, cell phone number etc. we recommend to be SIM card number, and record the ID. The valuable range is 1~32 bytes. Display Debug Info Debug information is use for engineer solve the problem, usually, it should be OFF.

Attention: If turn on the debug information, the configuring software may predictable behavior during read/write ACTM parameters, then we should turn off debug information, and re-connect ACTM.

Enable Camera ACTM supports remote image capture function, connected through the RS٢٣٢ interface with the camera, when ACTM connects with camera; you need to turn this option ON. ACTM Communication Mode ACTM support 5 mode to communication with center: TCP mode, ACTM communication with data center via GPRS, and establish TCP connection with data center. UDP mode, ACTM communication with data center via GPRS, and establish UDP connection with data center. SMS mode, ACTM sends the alarm information via SMS to the service center number.

Page 45: Actm usermanual

GPRS/SMS ACTM User manual

٤٥

TCP + SMS mode, ACTM communicate with data center via GPRS , and establish TCP connection with data centers; but also support SMS functions, when alarm generated, ACTM will send alarm information through GPRS and SMS at same time. At the applicaiton, GPRS for data center, SMS end user to receive alarm at real time. UDP + SMS, ACTM communicate with data center via GPRS , and establish UDP connection with data centers; but also support SMS functions, when alarm generated, ACTM will send alarm information through GPRS and SMS at same time. At the applicaiton, GPRS for data center, SMS end user to receive alarm at real time. Config Password Using ACTM Configuration software to set up ACTM, it need password. Please enter new password. The default value is 000000。

Attention: Please do not change the configuration password, if the password is incorrect, you will not able to set ACTM through configuration software. If you forget password, you can enter to the serial window, enter the command "at + ACTMdefault" to restore the default parameter, the password will restore the initial value of ٠٠٠٠٠٠.

Buzzer ON/OFF ACTM embedded buzzer Defence Status Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM only monitor I/O status, but do not send alarm SMS. The default is not defence.

Notice: From turn ON Defence, ACTM will enter defence status after ١٠ seconds. ACTM supports alias name to SMS to ARM/DISARM, the user just simply type in arm or disarm by the service center number. The command "at+defence=١" alias name is "arm"; the command "at+defense=٠" alias name is "disarm".

Timing Arm Executive ARM at the specified time daily. Timing Arm Executive disarm at the specified time daily. Password Disarm or Arm Any mobile phone can send SMS+password to remote disarm/arm, it can be set to maximum of ١٠ password, separated by commas. The default password is *, it means none. For example: send SMS”at+defence=1,123456” the 123456 is password, 1 means arm, 0 means disarm.

Notice: This function is use for remote arm/disarm, if there is people who wanna enter to the area, he can send password to arm/disarm. After SMS command send successful, ACTM will return an sucssful SMS, and send copy to the administrator phone.

RFID/Alarm Resend Times For data center to receive all the alarm, ACTM can set resend alarm times, value is 0-65535. GPRS mode: ACTM resend alarm packet times if didn't receive center alarm ACK packet; SMS mode: ACTM resend alarm SMS times if didn't receive cellphone alarm ACK SMS.

Page 46: Actm usermanual

GPRS/SMS ACTM User manual

٤٦

Notice: Set value as non ٠, the functional will effect. At the SMS mode, service number received alarm SMS should reply ACK SMS to the ACTM, otherwise ACTM will resend alarm SMS. There is a serial number for each alarm SMS, service number should reply ACK SMS as format: ACK - serial number, for example: ACK -١٢, service number reply ACTM that receives the serial number ١٢ alarm SMS.

RFID/Alarm Resend Interval ٦٥٥٣٥-٠ Seconds, ACTM resend alarm data packet interval if do not receive alarm ACK (Include GPRS and SMS) Continue Alarm Interval ٦٥٥٣٥-٠ Seconds, When more than one alarm occurs, the time interval between continue alarm I. System Parameter ACTM system information, the option is only for query, it cannot be modify; click the left mouse button on "System"; enter to the system information, the picture shown as below:

Manufacturer Name The default is Arian Ertebat Caspian Co. The Parameter is only for view. Product Model The default value is ET٨٠٠٠ GPRS/SMS ACTM,The Parameter is only for view. Software Version ACTM software version, The Parameter is only for view. Hardware Version ACTM hardware version, The Parameter is only for view. Config Tool Version Config Tool Version, The Parameter is only for view. Product SN ACTM product SN, the Parameter is only for view. Product Number

Page 47: Actm usermanual

GPRS/SMS ACTM User manual

٤٧

ACTM product number, The Parameter is only for view. IMEI Number ACTM IMEI Number, The Parameter is only for view.

Page 48: Actm usermanual

GPRS/SMS ACTM User manual

٤٨

Chapter 5 Typical Application This chapter describes in detail about ACTM typical application, by reading this chapter, the reader should be able to know choose suitable mode and set up ACTM.

١. SMS alarm application ٢. ACTM management platform application ٣. Transparent data transmission application

٥.١ SMS alarm application

For a small number of sites, SMS time delay is acceptable, simple operation, easy maintenance project, we recommended using SMS mode, the user can remote monitoring system through mobile phone, when an alarm occurred, ACTM will send SMS to mobile phone, according to alarm, the user can send commands directly control ACTM. The detailed SMS command instructions please check the attachment. Set ACTM to SMS mode that needs to configure the following parameters:

Service Number For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please pay attention to add country code on the front, the number is for receive alarm SMS from ACTM, and remote control ACTM through SMS. You can set up max four service center number. and must be set to at least one central number to take SMS mode effect. SMS Alarm Content For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the alarm happen, ACTM will send the pre-set SMS to service number. Customize SMS mode, ACTM will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send alarm SMS according Arian protocol Pre-set customize SMS is more easy to read alarm information, we recommend using a customize SMS. DI Alarm Status Low level, when port is low level, alarm happen; High level, when port is high level, alarm happen ;Status Change, when the port status change, alarm happen. The default is Disable alarm.

Page 49: Actm usermanual

GPRS/SMS ACTM User manual

٤٩

According to the actual situation, set the I/O port alarm status, we only make example on DI port, please set AI and TE port alarm status at same. DI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, tower water level is low! DI Alarm Clear Customize SMS The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning, tower water level return to normal! ACTM ID Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be location name, owner name, cell phone number etc. we recommend to be SIM card number, and record the ID. The valuable range is 1~32 bytes. ACTM Communication Mode ACTM communication with center mode; SMS mode, ACTM using SMS to communication with service number; TCP and UDP mode, ACTM using GPRS to communication with data service center. It must be set as SMS mode. Defence Status Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM only monitor I/O status, but do not send alarm SMS. The default is not defence. It must be set as Defence status, so ACTM can monitor I/O port, and send alarm SMS.

Attention: ACTM has a clock function, and using SMS to synchronization time, power up on ACTM for the first time, please send "Timecal" SMS to ACTM through mobile phone, then ACTM will reply "ACTM OK". Just set up once, ACTM will always using the clock running. For the command detail, please check Chapter ٧. Notice: After setting these parameters, we need to restart ACTM to take function effect. According the sensor installation, please check Chapter ٣ Installation.

٥.٢ ACTM management platform application

For more sites, complicated network, real-time is necessary, alarm history project, we recommend using ACTM management platform. ACTM management platform through the SQL database to save all alarm history, it's easy to use, and able to export excel report; through GOOGLE map to showing the location of all site, when an alarm occurs, the alarm immediately show red alarm logo on the map; with B/S structure, the user can management all device at anywhere where just open browser; multi-level permissions can be set to view and manage permissions, for normal users can only able to view, cannot operation. Below picture shown ACTM management platform software, more information please check Arian website.

Page 50: Actm usermanual

GPRS/SMS ACTM User manual

٥٠

Set ACTM to connect ACTM management platform mode that needs to configure the following parameters:

APN Name (APN) Follow the prompts to enter information into the access point name (access point name cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" button on the navigation bar ", the message bar will show "parameters set successfully". According to different operator, enter to the correct APN name. Main IP address x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center through domain name. Main Domain Name Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center.

Notice: The main IP address and main domain name must be input, if else, ACTM will not able to communication with ACTM platform.

Main Port ٦٥٥٣٥-١, Main data center IP port Work mode GPRS transmission work mode, IO protocol mode will send&receive data through Arian protocol, and it use for connect ACTM management platform; transparent mode, using the

Page 51: Actm usermanual

GPRS/SMS ACTM User manual

٥١

transparent data channel, and sends heartbeat packets, it’s for connect to other platform or data center. It must be set as IO protocol mode, so ACTM will use Arian communication protocol to connect with ACTM platform. DI Alarm Status Low level, when port is low level, alarm happen; High level, when port is high level, alarm happen ;Status Change, when the port status change, alarm happen. The default is Disable alarm. According to the actual situation, set the I/O port alarm status, we only make example on DI port, please set AI and TE port alarm status at same. ACTM Communication Mode ACTM communication with center mode; SMS mode, ACTM using SMS to communication with service number; TCP and UDP mode, ACTM using GPRS to communication with data service center. It must be set as TCP or UDP mode. Defence Status Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM only monitor I/O status, but do not send alarm SMS. The default is not defence. It must be set as Defence status, so ACTM can monitor I/O port, and send alarm information.

Notice: After setting these parameters, we need to restart ACTM to take function effect. According the sensor installation, please check Chapter ٣ Installation.

٥.٣ Transparent data transmission application

As RTU and PLC which provide RS٢٣٢ interface, ACTM provides RS٢٣٢ interface to connect with RTU and PLC, using transparent data channel that send RTU data to data center. Data center can use the RTU software or data center platform to receive ACTM+RTU data. Set ACTM to transparent data transmission mode that needs to configure the following

APN Name (APN) Follow the prompts to enter information into the access point name (access point name cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" button on the navigation bar ", the message bar will show "parameters set successfully". According to different operator, enter to the correct APN name. Band Serial port configuration, selectable baud rate is ١١٥٢٠٠-٣٠٠.

Attention:

Page 52: Actm usermanual

GPRS/SMS ACTM User manual

٥٢

This band is same band with configuration software connect to ACTM, if you modify this band rate, simultaneously modify configuration band, then the configuration software able to connect the ACTM.

Main IP address x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center through domain name. Main Domain Name Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center.

Notice: The main IP address and main domain name must be input, if else, ACTM will not able to communication with ACTM platform.

Main Port ٦٥٥٣٥-١, Main data center IP port Work mode GPRS transmission work mode, IO protocol mode will send&receive data through Arian protocol, and it use for connect ACTM management platform; transparent mode, using the transparent data channel, and sends heartbeat packets, it’s for connect to other platform or data center. It should be set as transparent mode usually, ACTM will use transparent channel to connect with data center. If the data center use Arian ACTM management platform while using the RTU, then select IO protocol mode. ACTM Communication Mode ACTM communication with center mode; SMS mode, ACTM using SMS to communication with service number; TCP and UDP mode, ACTM using GPRS to communication with data service center. It must be set as TCP or UDP mode.

Notice: After setting these parameters, we need to restart ACTM to take function effect. According the sensor installation, please check Chapter ٣ Installation. ACTM provides storage and forwarding the command functions of the MODBUS protocol, users can pre-save the common command to ACTM, and ACTM will send the command PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically. Please contanct Arian technical engineer for instruction detail.

Page 53: Actm usermanual

GPRS/SMS ACTM User manual

٥٣

Chapter 6 Operation This chapter describes in detail about ACTM operation and troubles shooting, by reading this chapter, the reader should be able to solve general ACTM problem.

١. Panel Indications ٢. ACTM operation Guidance ٣. Trouble Shooting

٦.١ Panel Indications

There are four LEDs at ACTM-9220 ACTM front panel; it indicates the ACTM network, operation and alarm status. The below form is the LED indicators description:

Status Sub-Status PWR NET DATA ALM

Initial state

Initialing Lights Up Lights Down Lights Up

Check SIM Lights Up 1 Second Flash Lights Down GPRS Dial up Lights Up Lights Down 0.3 Second

Flash

GPRS registing Lights Up 0.3 Second Flash

Lights Down

Connecting to Data center

Lights Up 0.3 Second Flash

0.3 Second Flash

Work state

GPRS Standby(Sleep)

Lights Up Lights Down 5 Second Flash

GPRS/SMS work status

Lights Up According the Signal strength

to flash

Flash on data

transmission

Light Up at battery power, flash at alarm

happen

Notice: After ACTM work well, the NET indicator will blink according to the signal strength, ACTM will query signal strength per minute. CSQ Signal strength in the ١٢-٠١, very fast flash; CSQ signal strength in the ١٨-٠٣, fast blinking; CSQ signal strength in the ٣١-١٩, slow blinking; After ACTM work well, PWR indicator will light up, DATA and NET indicator will light up for 2 seconds and light down for 2 seconds. ALM indicator and buzzer that there is alarm occur, it will buzz or blink. When ACTM switch to battery power, the ALM LED will light UP.

Page 54: Actm usermanual

GPRS/SMS ACTM User manual

٥٤

٦.٢ ACTM operation Guidance

ACTM is an intelligent wireless data terminal; after installation and setting, just connect sensor and power, then it will work well. ACTM should be installed at place with good radio signal receiving. For the cabinet and basement environment, we recommend to extend the antenna.

Warning: For outdoor use, lightning should be considered. We propose to install an arrester between antenna and the ANT interface. Contact Arian technical support department for details.

No routine maintenance is required for ACTM operation. At embedded application environment, the data service center will check ACTM operation information.

٦.٣ Trouble Shooting

Problem ١: All LEDs do not light up. Check all cables that are connected to the ACTM. Check the power supply adapter output voltage. If the power is correctly connected and there is no LED that light up, the ACTM may be failed. Contact to Arian or reseller for repairing. Problem 2: Instability after working long time. Please check whether the device is overheating, if overheated, put device into place in order to facilitate ventilation and cooling equipment. Problem 3: Using the configuration software to connect ACTM, but always unsuccessful. It needs to select the correct serial port and rate to connect ACTM, the default rate is ١١٥٢٠٠.

Attention: if use of USB-RS٢٣٢ converter cable to connect ACTM, please use Arian configuration cable. If use other brand of USB converter cable, please pay attention to buy high-quality cable, there is many bad-quality cable on the market, it may occur many problem to connect. In addition, PC's serial port is very easy to down, sometimes, you need to restart PC, and then try to connect.

Problem 4: I have already connected the sensor, set the port alarm status, but when an alarm is occurred, ACTM did not send the alarm information. Please check to set ACTM defence to be "defence" status, after set to "defence" status that wait for ١٠ seconds, ACTM will start monitor I/O port status. Problem 5: I'm using the configuration software, and already connect to ACTM successful, but when I query/save parameter, it show query/save failed, so I cannot config parameter. ACTM in without cards or GPRS connection mode, it may automatically restart after connect ACTM unsuccessful, when you open the configuration software for while, it show errors, so ACTM may be restarted, then just click "connect" button, configuration software

Page 55: Actm usermanual

GPRS/SMS ACTM User manual

٥٥

will try to connect ACTM again. Now, try to query/save parameter that will be successful. We suggest insert SIM first then set up ACTM. Problem 6: I'm using the configuration software, but there is many parameters are illegal value. The reason that's open the debugging information, ACTM debug information is large amount of data; it may affect configuration software to read/write parameter from ACTM sometimes. so please turn OFF the ACTM debug information then using the configuration software. Problem 7: ACTM shows ٤ lights flashing simultaneously, buzzer alarms fast flash, data cannot communication. This problem is ACTM internal battery will be no power soon. Please check the external power supply, and the power cord, you can check it on the ١٢PIN terminal. Problem 8: I connected ١٢V relay to ACTM DO port, set DO port output as high lever through configuration software, but the relay didn't action. DO port supply voltage is same Vin pin voltage, if using ١٢V relay, make sure the Vin pin voltage is the same as ١٢V. also, check the external power supply, if external power lose, ACTM will use internal battery, then DO only has ٣.٧V voltage, so relay will no action also. Problem 9: After turn ON ACTM power, it display PWR, DATA, NET, ALM all are lights up, and ACTM does not work. ٤ lights up means the ACTM is in the software upgrade status check the upgrade firmware button on the configuration cable, just press the button, and restart the ACTM, ACTM will return to normal mode. Problem 10: ACTM buzzer sometimes occur a short "TA"sound. This is normal, when ACTM is no signal or cannot connect to data center for many times, it will automatically restart, the buzzer will occur short "TA" sound. Problem 11: Set up ACTM service center number, but the number does not receive alarm SMS. Check the service center number is that fill in correct format, the numbers must add the country code + or ٠٠ in the front, if doesn't fill in the country code or the + and ٠٠ doesn’t in the front, ACTM may not able to send out SMS.

Page 56: Actm usermanual

GPRS/SMS ACTM User manual

٥٦

Chapter 7 Attachment SMS

Command This chapter describes in detail about SMS command detail, by reading this chapter, the reader should be able to how to remote control ACTM by SMS.

١. Introduction ٢. Command format ٣. Command list ٤. Command detail ٥. Alarm information format

٧.١ Introduction

ACTM SMS command list defines a format of SMS communication format, its use for ACTM and the cell phone communication each other. Users should follow this document to the remote control ACTM by SMS. This command list applies to all ACTM products.

٧.٢ Command format

A. ACTM commands were signed by the command code, Parameter separator, parameters, three major elements; multiple parameters can be composed of the parameter list. Command total length should not exceed ٥٠ characters, if the command is too long, it can be sent by multiple divided SMS. Command Parameter separator Parameter, Parameter listCommand “=” ( Separator between command and

parameters) “,”(Separator between Multiple parameters) “?”(Enquiry symbol)

Parameter

Command=param1,param2,param3…….. Command?

Attention: We must be set ACTM service number to be remote cell phone number, other phone numbers send commands to the ACTM, ACTM will do not implement.

Page 57: Actm usermanual

GPRS/SMS ACTM User manual

٥٧

٧.٣ Command list

Timecal ACK At+ACTMpsw At+ACTMrst At+transtype At+ACTMid At+almlvset At+almlvread At+almbat

At+defence At+outctrl At+inctrl At+almclr At+almpoint At+almsect At+servnum At+servalm At+almparam

At+almflag At+mservip At+bservip At+mservname At+bservname At+sleepmode At+conntry At+miscintv At+accinfo

٧.٤ Command detail

Command Timecal Function SMS Clock synchronization commandParameter None MEMO This command only through SMS, it cannot implement by console port.Example: Timecal Returns: ACTM TIME CALIBRATION OK,2011/01/18-09:54:47

Command At+ACTMrst Function ACTM reboot Parameter None MEMO There is no response SMS from ACTM, after send command, ACTM will

restart immediately. Example: At+ACTMrst Returns:

Command At+transtype Function ACTM with data center communication wayParameter ? Query the command current value, example: At+transtype?

0 Using SMS for communication with service center cell phone 1 Using TCP for communication with data center 2 Using UDP for communication with data center 3 Using TCP+SMS for communication with data center 2 Using UDP+SMS for communication with data center

MEMO The default is 0,SMS mode Example: At+transtype=1 Returns: transtype = ١ ACTM OK

Command At+ACTMid

Page 58: Actm usermanual

GPRS/SMS ACTM User manual

٥٨

Function ACTM ID (it cannot exceed 32 letters), this ID is ACTM identify number, the service center to identify different SMS by this ID.

Parameter ? Query current command value, example: At+ACTMid? ID Change ACTM ID to current value

MEMO Example: At+ACTMid=SHENZHEN At+ACTMid? Returns: ACTM ID:SHENZHEN ACTM OK

Command At+almlvset Function Set I/O port alarm levelParameter Para1, para2, para3

Para1 port name, it is DI,AI,TE Para2 port number, it is 1,2,3,4,5,6,7 Para3 port value: DI port: value 0, disable alarm value 1, low level alarm value 2, high level alarm value 3, the level status change alarm AI port: Min*Max, when AI port current value exceed range above +10, ACTM will occurred alarm, when AI port return to normal range -10, ACTM will occurred alarm clear. TE port: Min*Max, when TE port current value exceed range above +1, ACTM will occurred alarm, when TE port return to normal range -1, ACTM will occurred alarm clear.

MEMO Example: Set DI3 port high level alarm command is as below: At+almlvset=DI,3,2 Set AI1 port minimum value to 0, Maximum value to 100: At+almlvset=AI,1,0*100 Set TE1 port minimum value to -20, Maximum value to 70: At+almlvset=TE,1,-20*70 Returns: DI:٠x٠٠٠٠٠٠٢٠ ACTM OK

Command At+almlvread Function Query IO port alarm valueParameter Para1, para2

Para1 port name, it is DI, AI, TE, if there is no para2, the command will query all of port name value. Para2 port number, it is 1,2,3,4,5,6,7

MEMO Example: Query DI3 port alarm value: At+almlvread=DI,3 Query all of AI port alarm value: At+almlvread=AI Query TE1 port alarm value: At+almlvread=TE,1

Page 59: Actm usermanual

GPRS/SMS ACTM User manual

٥٩

Returns: DI(٠٣)LV=٢ ACTM OK

Command At+inctrl Function Query current IO port statusParameter Para1, para2

Para1 port name, it is DI, AI, TE, ALL; ALL will query all of Port value. Para2 port number, it is 1,2,3,4,5,6,7

MEMO Example: Query DI3 port current value: At+inctrl=DI,3 Query TE1 port current value: At+inctrl=TE,1 Query ALL port current value: At+inctrl=all Returns: ٠,0,0,0,0,0,0,0 0,364,340,424 0,36 ACTM OK MEMO:the first line of returns is DI port current value, the second line of returns is AI port current value, the thired line of returns is TE port current value.

Command At+outctrl Function Control DO port output high level or low level; High level: DC12V Low

level: 0V Parameter ? Query DO port current output status, example: At+outctrl?

Para1, para2 Para1 DO port number, it is 1,2,3,4 Para2 port value, 0 is low level, 1 is high level.

MEMO Note: DO ports with memory function, if there is power-off, restart, ACTM can automatically restore the previous settings of the state. But there is always low level during ACTM boot. Notice: If set At+almlink, the At+outctrl command will be unfunction, the DO port will only control by port alarm.

Example: Set DO1 port output high level At+outctrl=1,1 Query DO port current output status At+outctrl? Returns: DO:١,١,١,١ ACTM OK

Command At+almbat Function Detect external power statusParameter ? Query command current value, example: At+almbat?

0 ACTM do not detect external power status, not occurred alarm. 1 ACTM detects external power status, if there is change, ACTM will occur alarm.

MEMO The default value is 1.Example:

Page 60: Actm usermanual

GPRS/SMS ACTM User manual

٦٠

Set detect external power status: At+almbat=1 Returns: power status check enable ACTM OK

Command At+defence Function Defence or not defenceParameter ? Query current command value, example: At+defence?

٠ not defence, all IO ports are not in the surveillance state, that does not occurred alarm information ١ defence all IO port are in the surveillance state.

MEMO The default value is 1.Alias name "at+defence=١" alias name is "arm";

"at+defense=٠" alias name is "disarm". Example: Set ACTM defence At+defence=1 Returns: DEFENCE ACTM OK

Command At+almclr Function Alarm clear messageParameter ? Query command current value, example: At+almclr?

٠ do not send alarm clear message ١ send alarm clear message

MEMO The default value is 1Example: Set ACTM send alarm clear message At+almclr=1 Returns: ON ACTM OK

Command At+almpoint Function Set ACTM report IO port status as appoint time everyday Parameter ? Query command current value, example: At+almpoint?

Para1,Para2 Para1 0 disable function, 1 enable function Para2 time format: hh:mm:ss

MEMO Example: Set everyday 12:30:15 report current IO port status At+almpoint=1,١2:30:15 Returns: auto send time point enable ACTM OK

Command At+almsect Function Set ACTM auto report IO port status as specify intervalParameter ? Query command current value, example: At+almsect?

Para1,Para2

Page 61: Actm usermanual

GPRS/SMS ACTM User manual

٦١

Para1 0 disable function, 1 enable functionPara2 Interval, the unit is second

MEMO Example: Set auto report interval as 8000 seconds At+almsect=1,8000 Returns: auto send interval enable auto send interval:٨٠٠٠ ACTM OK

Command At+servnum Function Set ACTM service center numberParameter ? Query command current value, example: At+servnum? It will display

4 service center number Para1,Para2 Para1 Service center number series number, it is 0,1,2,3 Para1 Service center number, any numbers.

MEMO Service center number is data center modem SIM card number or user cell phone number; ACTM will send alarm SMS to this number, the max number is 4.

Example: Send the second service center number as 13812345678 At+servnum=1,13812345678 Returns: to(١) :١٣٨١٢٣٤٥٦٧٨ ACTM OK

Command At+servalm Function Set service center number receive alarm messageParameter ? Query current value, example: At+servnum?

Para1,Para2,Para3,Para4 Para1 The first service center number receive alarm SMS, 0 is not receive, 1 is receive Para2 The second service center number receive alarm SMS, 0 is not receive, 1 is receive Para3 The third service center number receive alarm SMS, 0 is not receive, 1 is receive Para4 The fourth service center number receive alarm SMS, 0 is not receive, 1 is receive

MEMO If set service center do not receive alarm SMS, so this number will only remote configuration via SMS.

Example: Set only the third service center number receive alarm SMS At+servalm=0,0,1,0 Returns: ٠,٠,١,٠ ACTM OK

Command At+almparam Function Set ACTM SMS alarm resendParameter ? Query current command value, example: At+almparam?

Para1,Para2,Para3 Para1 Set center number do not response ACK, the resend SMS

Page 62: Actm usermanual

GPRS/SMS ACTM User manual

٦٢

retransmissions, if set as 0, disable alarm SMS receipt function, so alarm SMS will only send to center number once. Para2 Set alarm SMS resend wait interval, the unit is second Para3 Set continue alarm SMS interval, the unit is second

MEMO Example: Set retransmissions to be 3, resend SMS interval to be 300 seconds At+almparam=3,300,0 Returns: ٣,٣٠٠,٠ ACTM OK

Command ACK Function SMS receipt, if enable ACK function, center service number should reply

ACK SMS when receive alarm SMS. Parameter ٠٠1 ~ ٩٩٩ alarm SMS series number, all occurred alarm SMS has an

series number, Data center reply ACK with series number to inform ACTM that receive which alarm SMS already.

MEMO This command is only available through SMS.Example: Data center send SMS receipt, alarm SMS series number is 001 ACK -٠٠١ Data center send SMS receipt, alarm SMS series number is 2 ACK -٢

Command At+almflag Function Set GSM dial up center number and BuzzParameter ? Query command current value, example: At+almflag?

Para1,Para2 Para1 before send SMS alarm, ACTM will dial up center number to inform alarm occurred. 0 disable function, 1 enable function. Para2 Buzz, ٠ turn off buzz, 1 turn on buzz

MEMO GSM dial function default value is 0, Buzz default value is 0 Example: Set alarm to ring service number, and turn on buzz At+almflag =١,1 Returns: wtt[٠] = ١ wtt[١] = ١ wtt[٠] = ١ wtt[١] = ١ ACTM OK

*Command At+mservip Function Set main data center IP address, portParameter ? Query current command value, example: At+mservip?

Para1,Para2 Para1 Data center IP address, if using domain name, here should be 0.0.0.0 Para2 Port number

MEMO Example: Set main data center IP as 20.13.48.6, port as 5008 At+mservip=20.13.48.6,5008 Returns:

Page 63: Actm usermanual

GPRS/SMS ACTM User manual

٦٣

ip = ٢٠.١٣.٤٨.٦ port = ٥٠٠٨ ACTM OK

*Command At+bservip Function Set backup data center IP address, portParameter ? Query current command value, example:At+bservip?

Para1,Para2 Para1 Data center IP address, if using domain name, here should be 0.0.0.0 Para2 Port number

MEMO Example: Set backup data center IP as 10.23.48.6, port as 5007 At+bservip=10.23.48.6,5007 Returns: ip = ١٠.٢٣.٤٨.٦ port = ٥٠٠٧ ACTM OK

*Command At+mservnameFunction Set main domain name addressParameter ? Query current command value, example:At+mservname?

Para1 Domain name, any character MEMO Example: Set main domain name address as ACTM.Ariancn.com At+mservname=ACTM.Ariancn.com Returns: server name = ACTM.Ariancn.com ACTM OK

*Command At+bservnameFunction Set backup domain name addressParameter ? Query current command value, example:At+bservname?

Para1 Domain name, any character MEMO Example: Set Backup domain name address as ACTM.Ariancn.com At+bservname =ACTM.Ariancn.com Returns: server name = ACTM.Ariancn.com ACTM OK

*Command At+sleepmode Function ACTM sleep functionParameter ? Query current command value, example:At+sleepmode?

Para1,Para2 Para1 whether enable sleep function Para2 the wait time for enter sleep status, the units is second.

MEMO Detected the specified time that without data transmission RS٢٣٢ interface, and no IO alarm occurred, ACTM will go to sleep. The default is ٠, disable the sleep function

Example:

Page 64: Actm usermanual

GPRS/SMS ACTM User manual

٦٤

Enable sleep function, wait time as 300sAt+sleepmode=1,300 Returns: offline time = ٣٠٠ ACTM OK

*Command At+conntry Function GPRS re-connection mechanismParameter ? Query current command value, example:At+contry?

Para1,Para2,Para3,Para4 Para1 A number of times reconnection, if set to ٠, no change destination address, only try to connect the main channel address Para2 A number of times reconnection interval, the unit is second. Para3 two number of times interval, the unit is minuate Para4 retry to Register center times

MEMO Example: Set a number of times reconnect as 8, time interval as 600s, two number of times interval as 30 minutes, retry to register center times as ١٠ times. At+conntry=8,600,30,10 Returns: trycnt:٨ tryinterval:٦٠٠ trywaittime:٣٠ try register cnt:١٠ ACTM OK

*Command At+miscintv Function Re-onine interval during sleep mode, heartbeat package interval Parameter ? Query current command value, example:At+miscintv?

Para1,Para2,Para3 Para1 Re-online interval due sleep mode, the unit is second Para2 Heartbeat package interval, the unit is second

MEMO Example: Set re-online interval as 8000s, heartbeat package interval as 40s At+miscintv=8000,40 Returns: reconnect time:٨٠٠٠ heart beat time:٤٠ ACTM OK

*Command At+hback Function Heartbeat ACK function, if set as 1, when ACTM didn’t receive heartbeat

ACK package from data center for 3 times, ACTM will disconnect the link, and reconnect.

Parameter ? Query current command value, example:At+hback?Para1 0 disable function, 1 enable function

MEMO Example: Open the Heartbest ACK funcitonn At+habak=1 Returns: ACTM OK

Page 65: Actm usermanual

GPRS/SMS ACTM User manual

٦٥

*Command At+accinfo Function Set GPRS uername and password, APN nameParameter ? Query current command value, example: At+accinfo?

Para1,Para2,Para3 Para1 GPRS APN name Para2 GPRS username Para3 GPRS password

MEMO Example: Set APN name as CMNET, username and password as blank at+accinfo=CMNET,, Returns: apn:CMNET user: psw: ACTM OK

٧.٥ Alarm information format

٠٠٠٠١٢٦٧,ALARM,٠٠١,PWA1,0, ١٠:٤٧:٣-٢٠١١/٠١/١٨3Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that external power loses, ACTM switch to internal Li-battery, time is ١٠:٤٧:٣-٢٠١١/٠١/١٨3 ٠٠٠٠١٢٦٧,ALARM,٠٠٢, PWC1,1, ١٠:٤٧:٣-٢٠١١/٠١/١٨6Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that external power return, ACTM switch to external power, time is ١٠:٤٧:٣-٢٠١١/٠١/١٨6 ٠٠٠٠١٢٦٧,ALARM,٠٠٤,DIA١٠:٤٧:٣٨-١,١,٢٠١١/٠١/١٨Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that send series 004 alarm information, DI1 port alarm, the alarm status is high lever, time is ١٠:٤٧:٣٨-٢٠١١/٠١/١٨ ٠٠٠٠١٢٦٧,ALARM,٠٠٥,DIC١٠:٤٧:٣٩-١,٠,٢٠١١/٠١/١٨Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that send series 005 alarm information, DI1 port alarm clear, the alarm clear status is low lever, time is ١٠:٤٧:٣-٢٠١١/٠١/١٨9 ٠٠٠٠١٢٦٧,ALARM,٠٠٤,AIA١,900,١٠:٤٧:٣٨-٢٠١١/٠١/١٨Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that send series 004 alarm information, AI1 port alarm, the alarm value is 900, time is ١٠:٤٧:٣٨-٢٠١١/٠١/١٨ ٠٠٠٠١٢٦٧,ALARM,٠٠٥,AIC١٠:٤٧:٣٩-١,٠,٢٠١١/٠١/١٨Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that send series 005 alarm information, DI1 port alarm clear, the alarm clear value is 0, time is ١٠:٤٧:٣-٢٠١١/٠١/١٨9 ٠٠٠٠١٢٦٧,ALARM,٠٠٤,TEA١,39,١٠:٤٧:٣٨-٢٠١١/٠١/١٨Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that send series 004 alarm information, TE1 port alarm, the alarm value is 39, time is ١٠:٤٧:٣٨-٢٠١١/٠١/١٨ ٠٠٠٠١٢٦٧,ALARM,٠٠٥,TEC١,28,١٠:٤٧:٣٩-٢٠١١/٠١/١٨Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that send series 005 alarm information, TE1 port alarm clear, the alarm clear value is 28, time is ١٠:٤٧:٣-٢٠١١/٠١/١٨9 ٠٠٠٠١٢٦٧,ALARM,٠٠٧,DIC١٠:٥١:١٩-٢,٠,٢٠١١/٠١/١٨,DIA١٠:٥١:٢٠-٣,١,٢٠١١/٠١/١٨,DIC4,٠,٢٠١١/٠١٠:٥١:٢٠-١/١٨ Description: The ACTM terminal, ID is ٠٠٠٠١٢٦٧ that send series 007 alarm information, DI2 port alarm clear, the alarm clear status is low lever, time is ١٠-٢٠١١/٠١/١٨:51:19; DI3

Page 66: Actm usermanual

GPRS/SMS ACTM User manual

٦٦

port alarm, the alarm status is high lever, time is ١٠-٢٠١١/٠١/١٨:51:20; DI4 port alarm clear, the alarm clear status is low lever, time is ١٠-٢٠١١/٠١/١٨:51:20;

Notice: If set ACTM as “Customize SMS mode”, ACTM will add the customized information on the front of alarm message, then send SMS to cell phone.

For example: Water level is high, DIA٠٠٤ ,١٠:٤٧:٣٨,٠٠٠٠١٢٦٧-٢٠١١/٠١/١٨ ,١ ,١