Patient Rooms

  • View
    375

  • Download
    0

Embed Size (px)

Transcript

  • 1.STAFFPATIENTDESIGNgood adjacentlarge short staff patient good patientsecure low patient good stafftravelview & patienttoilet full family bassinet ICUbuilding doorvisibility distancedaylight privacy access zone location adaptable perimeter capableoutboard / headwall / mirrored outboard / headwall / same handed outboard / footwall / mirrored outboard / footwall / same handed inboard / headwall / mirrored inboard / headwall / same handed nested / footwall / mirrored TTTPATIENT PATIENT ROOMROOMPATIENTPATIENTROOMTROOM PATIENT PATIENTROOMROOM TTCORRIDOR CORRIDOR CORRIDOROUTBOARD INBOARDNESTED

2. Outboard Toilet | Toilet Room on HeadwallLRProsCons Short travel distance for staff Patient view/daylight diminished Good visibility for staff Low acoustic privacy for patient Adjacent toilet access Family zone limited Suitable for ICU adaptability Bassinet location may not be secure Standard building perimeter needs Works same-handed or mirrored 3. Outboard Toilet | Toilet Room on HeadwallL LDublin Methodist Hospital | Dublin, Ohio [271 sf patient room; 54 sf toilet room] 4. Outboard Toilet | Toilet Room on FootwallRLProsCons Short travel distance for staff Patient view/daylight diminished Good visibility for staff Low acoustic privacy for patient Suitable for ICU adaptation Family zone limited Standard building perimeter needs Cross-room access to toilet Works same-handed or mirrored Bassinet location may be security issue 5. Outboard Toilet | Toilet Room on FootwallTripoint Medical Center | Concord Township, Ohio [234 sf patient room; 40 sf toilet room] 6. Inboard Toilet | Toilet Room on Headwall RLPros Cons Good patient view/daylight opportunity Low visibility for staff Open family zone Greater travel distance for staff Adjacent toilet access Difficult to adapt to ICU Acoustic privacy for patient Entry access limited Standard building perimeter needs Works same-handed or mirrored Secure location for bassinet near family 7. Inboard Toilet | Toilet Room on Headwall RLNorton Brownsboro Hospital | Louisville, Kentucky [256 sf patient room; 64 sf toilet room] 8. Nested Toilet | Toilet Room on FootwallRLPros Cons Good patient view/daylight opportunity Low acoustic privacy for patient Open family zone Entry access limited Good visibility for staff Requires more building perimeter Suitable for ICU adaptation Requires larger grid for ICU layout Secure location for bassinet near family Greater available headwall length 9. Nested Toilet | Toilet Room on Footwall All Childrens Hospital | St. Petersburg, Florida [254 sf patient room; 56 sf ADA toilet room] 10. STAFFPATIENTDESIGNgood adjacentlarge short staff patient good patientsecure low patient good stafftravelview & patienttoilet full family bassinet ICUbuilding doorvisibility distancedaylight privacy access zone location adaptable perimeter capableoutboard / headwall / mirrored outboard / headwall / same handed outboard / footwall / mirrored outboard / footwall / same handed inboard / headwall / mirrored inboard / headwall / same handed nested / footwall / mirrored TTTPATIENT PATIENT ROOMROOMPATIENTPATIENTROOMTROOM PATIENT PATIENTROOMROOM TTCORRIDOR CORRIDOR CORRIDOROUTBOARD INBOARDNESTED 11. Outboard Toilet | Toilet Room on Headwall HealthcareADA Guidelinescompliant for ICUtoilet room Patient Bed:with roll-inshower 13 headwallCaregiver 5 atwork areatransfer side(including of patientarea for 5 at foot ofcart parking)patient 4 at non- transfer side[298 sf patient room; 56 sf ADA toilet room]