Building Science 2 (Arc 3413)Project 2: Integration with Design Studio 5
Lighting & Acoustic Calculation
Name: Nur Aida Ashikin Binti RosdiStudent ID: 0302503
Tutor: Dr. MinaSemester 5
1.0 Lighting Calculations
1.1 Gallery 1
Gallery 1
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRO
DU
CED
BY
AN
AU
TOD
ESK
ED
UC
ATI
ON
AL
PRO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRO
DU
CED
BY A
N A
UTO
DESK
EDU
CA
TION
AL PR
OD
UC
T
Gallery 1
1.1.1 Artificial Lighting: Lumen Method Calculation of Gallery 1 above 0.9m
Total Floor Area (m2) 142.64
Standard Luminance Required (lux) 300
Assumption of Reflection Glass wall, White Ceiling, Grey Floor= 0.3, 0.5, 0.3
Room Index = _21.059 x 8.997___3.1 x (21.059 + 8.997)
= 2.033
Utilisation Factor 0.49
Maintenance Factor 0.8
1.1.2.1 Proposed Light Fixtures
Tracklight Bulb Used
CT6038-GU24LineVoltage 120V
Front Loaded Gimbal
Essential MV MR16 Alu
Compact adjustable accent lights for a wide range of beam spreads in line voltage lamps.Yoke permanently adjuststo position lamp in any direction. Designed for use on either circuit of Capri combination one or two circuit track.
- Beam Angle: 40D- Luminous Intensity: 500 cd- 1894 Lm- Colour Temperature: 2800K- Colour Rendering Index: 100 Ra8- Lamp Wattage: 50 W
Tracklight Bulb Used
N = __E x A___ F x UF x MF
N = 150 x 142.64_ 1894 x 0.49 x 0.8
N = 28.8 = 29 Lamps
N = __E x A___ F x UF x MF
N = 150 x 142.64_ 1894 x 0.49 x 0.8
N = 28.8 = 29 Lamps
Spotlight Bulb Used
6" Incandescent Deep Recessed Housing Essential MV MR16 Alu
Compact adjustable accent lights for a wide range of beam spreads in line voltage lamps.Yoke permanently adjuststo position lamp in any direction. Designed for use on either circuit of Capri combination one or two circuit track.
- Beam Angle: 36D- Luminous Intensity: 600 cd- 1845 Lm- Colour Temperature: 2800K- Colour Rendering Index: 100 Ra8- Lamp Wattage: 50 W
N = __E x A___ F x UF x MF
N = 150 x 142.64_ 1845 x 0.49 x 0.8
N = 29.5 = 30 Lamps
N = __E x A___ F x UF x MF
N = 150 x 142.64_ 1845 x 0.49 x 0.8
N = 29.5 = 30 Lamps
29 spotlight and 30 lamps on track lights with is needed to illuminate the Gallery 2 with 300 lux standard for a gallery.
-5
1.2 Gallery 2
1.1.2 Artificial Lighting: Lumen Method Calculation of Gallery 2 above 0.9m
Total Floor Area (m2) 123.65
Standard Luminance Required (lux) 300
Assumption of Reflection Glass wall, White Ceiling, Grey Floor= 0.3, 0.5, 0.3
Room Index = _21.059 x 8.997___3.1 x (21.059 + 8.997)
= 2.033
Utilisation Factor 0.49
Maintenance Factor 0.8
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRO
DU
CED
BY
AN
AU
TOD
ESK
ED
UC
ATI
ON
AL
PRO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRO
DU
CED
BY A
N A
UTO
DESK
EDU
CA
TION
AL PR
OD
UC
T
Gallery 2
Gallery 2
1.1.2.1 Proposed Light FixturesTracklight Bulb Used
CT6038-GU24LineVoltage 120V
Front Loaded Gimbal
Essential MV MR16 Alu
Compact adjustable accent lights for a wide range of beam spreads in line voltage lamps.Yoke permanently adjuststo position lamp in any direction. Designed for use on either circuit of Capri combination one or two circuit track.
- Beam Angle: 40D- Luminous Intensity: 500 cd- 1894 Lm- Colour Temperature: 2800K- Colour Rendering Index: 100 Ra8- Lamp Wattage: 50 W
N = __E x A___ F x UF x MF
N = 150 x 123.65_ 1894 x 0.49 x 0.8
N = 24.9 = 25 Lamps
N = __E x A___ F x UF x MF
N = 150 x 123.65_ 1894 x 0.49 x 0.8
N = 24.9 = 25 Lamps
Spotlight Bulb Used
6" Incandescent Deep Recessed Housing Essential MV MR16 Alu
Compact adjustable accent lights for a wide range of beam spreads in line voltage lamps.Yoke permanently adjuststo position lamp in any direction. Designed for use on either circuit of Capri combination one or two circuit track.
- Beam Angle: 36D- Luminous Intensity: 600 cd- 1845 Lm- Colour Temperature: 2800K- Colour Rendering Index: 100 Ra8- Lamp Wattage: 50 W
N = __E x A___ F x UF x MF
N = 150 x 123.65_ 1845 x 0.49 x 0.8
N = 25.6 = 26 Lamps
N = __E x A___ F x UF x MF
N = 150 x 123.65_ 1845 x 0.49 x 0.8
N = 25.6 = 26 Lamps
26 spotlight and 25 lamps on track lights with is needed to illuminate the Gallery 2 with 300 lux standard for a gallery.
1.3 Restaurant
1.3.1 Artificial Lighting: Lumen Method Calculation of Restaurant above 0.8m
Total Floor Area (m2) 67.12
Standard Luminance Required (lux) 200
Assumption of Reflection Glass wall, White Ceiling, Grey Floor= 0.3, 0.5, 0.3
Room Index = _10.320 x 6.504___3.2 x (10.320 + 6.504)
= 1.25
Utilisation Factor 0.41
Maintenance Factor 0.8
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRO
DU
CED
BY
AN
AU
TOD
ESK
ED
UC
ATI
ON
AL
PRO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRO
DU
CED
BY A
N A
UTO
DESK
EDU
CA
TION
AL PR
OD
UC
T
1.1.2.1 Proposed Light FixturesDown Light Bulb Used
40550copper/brass
LED
Luster energy saving bulb 8710163226682
8 W (25 W) E27 cap, Warm white
Available in matt black or lustrous gold color finish, this luminaire is treated with luxurious and high quality finishing and detailing
- Wattage: 20 W- Light effect/finish: Warm White- Light output: 1070 lumen- Color temperature: 2700 K- Color rendering index (CRI): 81
N = __E x A___ F x UF x MF
N = 100 x 67.12_ 1070 x 0.41 x 0.8
N = 19.12 = 20 Lamps
N = __E x A___ F x UF x MF
N = 100 x 67.12_ 1070 x 0.41 x 0.8
N = 19.12 = 20 Lamps
Track Light Bulb Used
MASTER LEDspot MV
Star's sleek, polished lamps are fully rotatable to any angle for you to instantly add striking accents to your room with its bright focused light. Available in 1, 2, or 4 lamp combinations.
Beam Angle 40 DColour Temperature: 2700 KLuminous Intensity: 600 cdColour rendering index: 80Light Output: 2734
N = __E x A___ F x UF x MF
N = 100 x 67.12__ 2734 x 0.41 x 0.8
N = 7.48 = 8 Lamps
N = __E x A___ F x UF x MF
N = 100 x 67.12__ 2734 x 0.41 x 0.8
N = 7.48 = 8 Lamps
20 downlight and 2 track lights with 4 lamp combination is needed to illuminate the Restaurant with 200 lux standard for dining area.
2.0 Acoustic Calculations
2.1 Reverberation Time (RT)
2.1.1 Internal Space - Music WorkshopMaterials Absorption
Coefficient at 1000 Hz
Surface Area(m2)
Sa
Plaster (gypsum or lime, on masonary) 0.03 60.51 1.8153
Carpet 0.15 18 2.7
Glazed Tile 0.01 42.51 0.4241
Seats (fabric-upholsterd, empty) 0.88 3 2.64
Seats (fabric-upholsterd, fully occupied) 0.96 5 4.8
Glass Wall 0.03 20 0.6
People 0.46 4 1.84
Acoustic Panels 0.85 39.5 33.575
Concrete Wall 0.02 81.46 1.6292
Total Absorbtion Area = 1.8153 + 2.7 + 0.4241 + 2.64 + 4.8 + 0.6 + 1.84 + 33.575 + 1.629 = 50.02
Volume of Space = 242.04 m3
Reverberation Time = 0.16 x Volume Total Sa
= 0.16 x 242.04 50.02
= 0.78
Standard Table requires a Music Room/Workshop to have a reverberation time of 1.5/s for a clear and crisps sound quality for music recording or jamming.
2.2 External Noise Sound Level Pressure (SPL)Traffic Noise of H.S. Lee Road: 76dB Opposite Trading Activities Noise: 70dB
76 = 10 log ll
1 x 10
Antilog 7.6 = ___ll___ 1 x 10
ll = (3.981 x 10 ) x (1 x 10 ) = 3.918 x 10
70 = 10 log ll
1 x 10
Antilog 7 = ___ll___ 1 x 10
ll = (1 x 10 ) x (1 x 10 ) = 1 x 10
Total Intensities = (3.981 x 10 ) + (1 x 10 ) = 4.981 x 10
Combined SPL = 10 log 4.981 x 10 1 x 10 = 10 x 8.607 = 77dB
Total Intensities = (3.981 x 10 ) + (1 x 10 ) = 4.981 x 10
Combined SPL = 10 log 4.981 x 10 1 x 10 = 10 x 8.607 = 77dB
Calculation above shows the external noise sound pressure level (SPL) of both traffic and trading noise around the site on Jalan Tun H.S. Lee.
-12
-12
-12
-12
-127-5
-5
-5 -5
-5
-12
7
2.3 Sound Reduction Index (SRI)
2.3.1 Music Workshop ( Internal Noise Source) to Outdoor WalkwayBased on the table above, average sound pressure level produced for a Music Workshop/Room is 90 db which considered as internal noise source to the Outdoor Walkway.
The East Wall of the Workshop consist of 5.2 m(square) of Concrete Wall(SRI=42dB) and 15.66 m(square) of glass wall (SRI=26dB)
SRI = 10 log 1 T
TL For Concrete Wall TL for Glass Wall
42 = 10 log 1 T
Antilog 4.2 = 1 T
T = ____1___ 1.585 x 10
T = 6.310 x 10
26 = 10 log 1 T
Antilog 2.6 = 1 T
T = ____1___ 3.98 x 10
T = 2.512 x 10
T overall = (5.2 x 6.309 x 10 ) + ( 15.66 x 2.512 x 10 ) 5.2 + 15.66
= 1.902 x 10
SRI overall = 10 log 10 1 ___ 1.902 x 10
= 10 log 10 525.89
= 27.2 dB
Total noise level transmitted to Outdoor Walkway: 90db - 27.2dB = 63dB
The wall made out of material of glass and concrete reduces 27.2dB of noise to the walkway. 63dB is similar to a busy road and could disturb people using the walkway. Howover, the walkway is only used as a circulation space and surely users would not mind the noise.