Page 1: Starline critical power monitor w m50

Introducing: StarlineCritical Power Monitor

Page 2: Starline critical power monitor w m50

Wired and Wireless OptionsUp to six channels availableModbus RTU, SNMP ProtocolsTelnet and Modbus TCP/IP Protocols

Page 3: Starline critical power monitor w m50

General Information: The newest version of the Starline Critical Power

Monitor (CPM) minimizes the footprint needed within the Starline Track

Busway plug-in units, thus maximizing the plug density options for the

installation.

Starline is further enhancing its ability to monitor and manage power

consumption in data centers with the introduction of the latest version of the

Critical Power Monitor (CPM). The CPM is a revenue-grade power monitoring

device that proactively monitors power usage and distribution in the data center

environment, enabling organizations to maximize energy management and

efficiency.

The M50 Meter

Page 4: Starline critical power monitor w m50

Why M50 Series?

• Our Customers Told Us:

• They like M40 Series functionality, reliability

• Reduce footprint – Busway real estate is king

• Improve price point

Page 5: Starline critical power monitor w m50

M40 Series Review

• Selling Points of the M40 Series

• Extensive feature set– Revenue grade metering functionality

– Monitors multi-circuit configurations

– End feed and branch circuit models

– Display and non-display versions available

– Wired Ethernet and Serial communications

– Wireless Ethernet (802.11n)

– Use Modbus and SNMP protocols simultaneously

– Integral Webpage

• Easily upgradable– Firmware updates as needed

Page 6: Starline critical power monitor w m50

M40 Series Review

• M40 Series - Confidence

• In-house expertise & support– Development Engineering

– Applications Engineering

• Testing– Environmental, Surge, Fast Transient, Communications, Display, Accuracy

– Extensive functional validation

– Beta Installations

Page 7: Starline critical power monitor w m50

M40 Series ReviewM40 Series – BMS/DCIM Integration

• Data Center Software Packages– Norlinx

– FieldView

– Power Assure

– Modius

– Liebert SiteScan

– APC Data Center Manager

– Intel DCM

• PDU Software Packages– Power IQ from Raritan

– ServerTech

– CPI

• UEC Engineering Support

Page 8: Starline critical power monitor w m50

Introducing the M50 Series of Meters

•How is this series different?

•What does it mean to me?

Page 9: Starline critical power monitor w m50

M50/V50 – What is New?M50 Series

• Retain M40 monitoring capabilities

– Revenue grade metering functionality

– Monitors multi-circuit configurations

– Wired Ethernet and Serial communications

– Wireless Ethernet (802.11n)

– Use Modbus and SNMP protocols simultaneously

– Integral Webpage

– Firmware updates as needed

• Maintain M40 compatibility

– Seamless communications

– Utilizes the same firmware files

M40

M50

Page 10: Starline critical power monitor w m50

M50/V50 – What is New?

M50 Series

• Optimize for typical Plug-in Unit applications– Reduced-width footprint Increased plug density

– First meter to fit an E12 with 2-pole breaker

• Simplify to reduce price point– Omitting display option reduces hardware overhead

– One voltage range (up to 480Vac) simplifies design

• M50 versus V50?

– M50: Monitor at Paddle

– V50: Monitor each Outlet

– Up to 4 individual devices

– Up to 6 CTs

E52 with (2) L630R

E12 with 2-pole breaker

Page 11: Starline critical power monitor w m50

M50/V50 – What is New?• M50 Series Configurations

• V5x monitors Outlets (typical application)

• M5x monitors Paddle

Page 12: Starline critical power monitor w m50

M50/V50 – What is New?

• M50 Series Communications

• Ethernet– Modbus TCP

– SNMP

– HTTP/S

– Telnet

– SSH

– BACnet TCP

• Modbus RTU

• •Wi-Fi (802.11n)– PIFA antenna

Page 13: Starline critical power monitor w m50

M50/V50 – What is New?• M50 Series Communications

• Daisy-Chain Ethernet Topology– Requires Dual Ethernet (M58/V58 or M59/V59)

– Reduces home runs to Ethernet switch

– Saves $Hundreds per chained CPM

Page 14: Starline critical power monitor w m50

M50 Status & Schedule

• M50 Series Test & Regulatory Status

• Functional• – Completed internal qualification testing similar to M40

• Beta

– Deploying in 4 countries

• UL–

Active file

UL Listing anticipated within July 2015

Page 15: Starline critical power monitor w m50

M50 Supporting Materials

• Documentation

• M40/M50 Series User Manual

• M40/M50 Series Quick Start Guides– Ethernet (wired and wireless)

– Modbus

– BACnet

• Support Files– MIB File

– Modbus Register Map

– BACnet PICS (Protocol Implementation Conformance Statement)

Page 16: Starline critical power monitor w m50
Page 17: Starline critical power monitor w m50
Page 18: Starline critical power monitor w m50

The Starline CPM also comes with an easy-to-install, user-friendly Web

interface so data center managers can quickly provision and implement the

device. Connectivity options for the CPM include both wired Ethernet and

Modbus, and an optional 802.11n Wi-Fi version is also available. The new

CPM release will include four versions:

1. Single Ethernet

2. Single Ethernet and Wi-Fi

3. Dual Ethernet

4. Dual Ethernet and Modbus RTU supporting a daisy-chain Ethernet topology

This daisy-chain topology saves on network switch ports within the facility.

Page 19: Starline critical power monitor w m50

Modbus RTU Monitors on three phase Plug-in units

Page 20: Starline critical power monitor w m50