2
EnvExp.com a Cole-Parmer company Syringe Filters Improve your flow rate with increased filtration area Description Filter diameter Pore size (µm) Without prefilter With prefilter Cat. no. Qty/pk Cat. no. Qty/pk Cellulose acetate 25 mm 0.45 SF045CA 200 SF145CA 200 Glass fiber 25 mm 1.20 SF012G 200 1.50 SF015G 200 Glass fiber, acid-washed, TCLP grade 25 mm 0.70 SF1070G 200 Nylon 13 mm 0.22 SF122N 100 0.45 SF1345N 100 25 mm 0.20 SF020N 200 SF120N 200 0.45 SF045N 200 SF145N 200 Polyethersulfone (PES) 25 mm 0.20 SF020E 200 SF120E 200 0.45 SF045E 200 SF145E 200 Polyvinyldifluoride (PVDF) 25 mm 0.20 SF020V 200 SF120V 200 0.45 SF045V 200 SF145V 200 PTFE 13 mm 0.20 SF122T 100 25 mm 0.20 SF020T 200 SF120T 200 0.45 SF045T 200 SF145T 200 2.00 SF200T 200 6.00 SF600T 200 Filtration area is 31% larger than comparable 25-mm syringe filters, increasing flow rate and filtration area Decrease your flow decay from particulate loading Minimize contamination of samples—housed in polypropylene that is naturally low in extractables Particle-free seal from ultrasonic welding Get better resistance to chemical degradation than acrylic housings Syringe filter housings have a standard slip-luer fitting on exit port and full-thread luer-lock fitting on entry port for easier attachment. Syringe filters with prefilters increase syringe filter capacity and decrease back pressure during filtration. This cut-away drawing of our improved syringe filter illustrates the use of our conical frustum design, which evenly supports the filter while allowing more open area for complete filtration of your sample. Call our Technical Services Department at 800-745-8218 with your specifications or email your specifications to [email protected]. In most cases we will have your pricing in 48 to 72 hours. Don’t see the right filter? We will customize filters to your needs: 1. Choose filter size, thickness and diameter 2 Specify filter material 3. Specify filter pore size 4. What substances are being filtered? 5. How many filters are needed (volume)? 6. Do the filters require a certification?

Syringe Filters

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Syringe Filters

EnvExp.com

a Cole-Parmer company

Syringe Filters

Improve your flow rate with increased filtration area

Description Filter diameter

Pore size (µm)

Without prefilter With prefilter

Cat. no. Qty/pk Cat. no. Qty/pkCellulose acetate 25 mm 0.45 SF045CA 200 SF145CA 200

Glass fiber 25 mm1.20 SF012G 200 — —1.50 SF015G 200 — —

Glass fiber, acid-washed, TCLP grade 25 mm 0.70 SF1070G 200 — —

Nylon13 mm

0.22 SF122N 100 — —0.45 SF1345N 100 — —

25 mm0.20 SF020N 200 SF120N 2000.45 SF045N 200 SF145N 200

Polyethersulfone (PES) 25 mm0.20 SF020E 200 SF120E 2000.45 SF045E 200 SF145E 200

Polyvinyldifluoride (PVDF) 25 mm0.20 SF020V 200 SF120V 2000.45 SF045V 200 SF145V 200

PTFE

13 mm 0.20 SF122T 100 — —

25 mm

0.20 SF020T 200 SF120T 2000.45 SF045T 200 SF145T 2002.00 SF200T 200 — —6.00 SF600T 200 — —

– Filtration area is 31% larger than comparable 25-mm syringe filters, increasing flow rate and filtration area

– Decrease your flow decay from particulate loading

– Minimize contamination of samples—housed in polypropylene that is naturally low in extractables

– Particle-free seal from ultrasonic welding

– Get better resistance to chemical degradation than acrylic housings

Syringe filter housings have a standard slip-luer fitting on exit port and full-thread luer-lock fitting on entry port for easier attachment. Syringe filters with prefilters increase syringe filter capacity and decrease back pressure during filtration.

This cut-away drawing of our improved syringe filter illustrates the use of our conical frustum design, which evenly supports the filter while allowing more open area for complete filtration of your sample.

Call our Technical Services Department at 800-745-8218 with your specifications or email your specifications to [email protected]. In most cases we will have your pricing in 48 to 72 hours.

Don’t see the right filter?

We will customize filters to your needs:

1. Choose filter size, thickness and diameter

2 Specify filter material

3. Specify filter pore size

4. What substances are being filtered?

5. How many filters are needed (volume)?

6. Do the filters require a certification?

Page 2: Syringe Filters

4398

2345A Charleston Regional Parkway, Charleston, South Carolina 29492Phone: 843-881-6560 Toll Free: 800-343-5319Web: EnvExp.comE-mail: [email protected]

a Cole-Parmer company

Filter Membrane Selection Guide

Membrane type Membrane characteristics and applications Flow rate Hydrophobic Hydrophilic Acid

resistantBase

resistantSolvent

resistant

Cellulose AcetateLow protein binding, ideal for aqueous-based samples. High protein recovery from filtrate. Tissue culture media filtration, general water filtration.

*** — **** — * **

Glass Fiber

Larger pore size. Able to remove large particles without clogging.General laboratory filtration. Ideal for solids testing.

**** — **** *** * ****

Nylon

Hydrophilic membrane, low in extractables.Broad compatibility with aqueous samples. Not highly compatible with acids and bases.General laboratory filtration. Ideal for HPLC applications.

** — **** — *** ***

PESHigh flow rate compatible with high-temperature liquids. Low in inorganic ions. Ideal for ion chromatography analysis.

**** — **** ** *** *

PVDFHydrophilic with good resistance to solvents. General laboratory filtration. Ideal for high protein recovery.

*** * *** **** **** ***

PTFE

Hydrophobic and resistant to most solvents, acids, and bases. Must be wetted with alcohol prior to filtering aqueous solutions. General laboratory filtration. Ideal for high protein recovery.

** **** — **** **** ****

Key: Each membrane is rated on a scale of 1-4 stars for fitness for specific properties, with 4 being the most effective, 1 being the least and — means not applicable.

Tip type Capacity Catalog number Qty/pkSlip luer 10 mL S0010 250Slip luer 20 mL S0020 250Luer lock 10 mL S0010LL 250Luer lock 20 mL S0020LL 250

Disposable SyringesWill not degrade or contaminate samples

– Inert polypropylene design

– Graduated for easy volume determination