All doctors wear gloves and makes when treating patients. After contact with each patient , the glovers are removed and discarded and are never reused for another patient .Gloves are removes or “overgloved” if the treatment of a patient is temporarily interrupted we wash our hand and then put on a new pair of gloves before treating another patient. Wherever possible (single use) item can be used, we use as many plastic cover as possible. All suction tips, saliva ejectors and water glasses are disposed off and replaces between each patients. Dental Clinic Noida| Basic Safety Measures Dental Clinic sin hsinghdental.co m/ ghdental.com

Singh Dental Clinic | Basic Safety Measures Dental Clinic

Embed Size (px)

Citation preview

Page 1: Singh Dental Clinic | Basic Safety Measures Dental Clinic

Al l doc to r s wear g l oves and makes when t rea t i ng pa t i en t s . A f t e r con tac t w i th each pa t i en t , the g l over s a re r emoved and d i scarded and a re never r eused f o r ano ther pa t i en t .G l oves a re removes o r “overg l oved” i f t he t r ea tment o f a pa t i en t i s t emporar i l y i n te r rup ted we wash our hand and then pu t on a new pa i r o f g l oves be fo re t r ea t i ng ano ther pa t i en t .Wherever poss ib l e ( s i ng l e use ) i t em can be used , we use as many p l as t i c cover as poss ib l e . A l l suc t i on t i p s , sa l i va e j ec to r s and wate r g l asses a re d i sposed off and rep l aces be tween each pa t i en t s .

Dental Clinic Noida| Basic Safety Measures Dental Clinic

sin hsinghdental.com/ ghdental.com

Page 2: Singh Dental Clinic | Basic Safety Measures Dental Clinic

singhdental.com

All The Instrument are scrubbed thoroughly with spirit to get rid of blood stains and debris.

After cleaning with the spirit swabs the entire instrument are immersed in digital ultrasonic cleaner along with triple enzymatic instrument and equipment cleaner.

Page 3: Singh Dental Clinic | Basic Safety Measures Dental Clinic

Stage.3These cleaned instruments are than immersed in 5% console sterilizing solutions for 45 minutes for standard deoinfution

Then instrument are packed in sterilization pouches and sterilized using autoclave an autoclave is a device use to sterilize equipment at a temperature (121.C) and (15lbs). Pressure.

singhdental.com/

Page 4: Singh Dental Clinic | Basic Safety Measures Dental Clinic

All sterile instruments are kept in UV chamber to maintain the sterilization.

Small instrument like bur and files are sterilized in green bead sterilizer.

Distill water in used in chairs as it the purest