Upload
addfield
View
47
Download
0
Tags:
Embed Size (px)
Citation preview
Addfield Environmental Systems LimitedHollies Park | Cannock | Staffordshire | WS11 1DBwww.addfield.co.uk | [email protected] | 01543 571280
‘The most thermally efficient,robust and reliablehuman crematorson the market
Simply Built Better!’
Control System
PHOENIX 2
Hot Hearth
PHOENIX 2 Human CrematorSuitable for 2500-3000 cremations a year
CFD Modelling
The PHOENIX 2 is our high volume human cremation unit. It bene�ts from 115mm refractory wall thickness and temperature controlled burners that ensure it has the lowest fuel consumption possible. Complete with a curved hot hearth design that contains and destroys high moisture content material. A touch screen control interface is employed with a fully automatic control sequence that removes the possibility of human error. It utilises a front loading door design for ease use and a separate remains removal door located on the rear of the unit. The main chamber has a volume of 2.574m³ and a maximum weight capacity of 453kg.
All i
nfor
mat
ion
shou
ld b
e us
ed a
s a g
uide
onl
y, sp
eci�
catio
ns a
re su
bjec
t to
chan
ge w
ithou
t not
ice.
PHOENIX 2
Human CrematorSuitable for 2500-3000 cremations a year
Robust, Reliable... ...and Efficient
Fuel Options:
† Based on general municipal waste streams* Depending on the type waste stream being loaded and excludes heat up time.
We reserve the right to change the speci�cation, dimensions and quality of materials from time to time, so long as the alteration is minor or an improvement to the said products.
†
Addfield Environmental Systems LimitedHollies Park | Cannock | Staffordshire | WS11 1DBwww.addfield.co.uk | [email protected] | 01543 571280
External Length (mm) External Width (mm) External Height (mm) -Including Door Cap (mm)
Minumum Stack Height (mm)Stack Diameter OD (mm)
Maximum Body Weight (kg)
Weight (Approx. Tonnes)
CE CertifiedEU Regulations Compliant
Max Load Capacity (kg) Nominal Burn Rate* (kg/hr) Thermal Capacity (kw/hr)
Power Supply 50/60hz
Diesel LPG N-Gas
3200250024002900
5400600
453
17.2
YESYES
45350-75190
210/230v
NoYesYes
The human cremation range is designed as a two stage cremation unit comprising of a primary loadingchamber that incorporates a hot hearth constructionfor the total destruction of the solid/liquid wastes. The unit is further complemented by an integral afterburner system; this afterburner draws the hot gases from the primary chamber under the hearth throughan integral refractory brick system. This ensures maximum gas turbulence/mixing is achieved thus aiding clean combusted gases. All gases then resideinside the after burner chamber for a minimum of 2 seconds at temperatures of 850-1150°C ensuring complete high temperature termination/oxidation ofthe gas combustion products.
The Add�eld range of human cremators are CE Certi�ed to BS EN 746-2 :1997 and are compliant with all emission regulations.
Machine Specifications: PHOENIX 2Primary Chamber Sizes:Internal Length (mm) Internal Width (mm) Internal Height (mm)
Chamber Volume (m³)
Front Opening Door Size:Width (mm)Height (mm)
Number Of Buners
26001100900
2.574
1100 800
3
All i
nfor
mat
ion
shou
ld b
e us
ed a
s a g
uide
onl
y, sp
eci�
catio
ns a
re su
bjec
t to
chan
ge w
ithou
t not
ice.
Machine Specifications: PHOENIX 2
Addfield Environmental Systems LimitedHollies Park | Cannock | Staffordshire | WS11 1DBwww.addfield.co.uk | [email protected] | 01543 571280
Secondary Chamber• Fully insulated internal refractory lining, constructed from high grade low thermal mass insulation. • One secondary chamber burnout burner, temperature controlled on-off, complete with internal air fans.• Integrated combustion burner air fans.• One temperature control sensor reaches the necessary 850°C minimum.• 76mm refractory lined stack that reduces heat penetration under every condition, preventing the possibility of fire.
Primary Chamber• Fully insulated internal refractory lining, constructed from high grade refractory brick ensuring a self-supporting interlocked arrangement, hot hearth design.• One hydraulic front loading door, push button operated.• One hot hearth combustion burner, temperature controlled on-off, complete with internal air fans.• One waste ignition burner, temperature. controlled on-off, complete with internal air fans• One temperature control sensor.
General Construction• Pre-fabricated from robust mild steel box tubing, with a thickness of 3.5mm externally and 2.7mm internally. Suitably stiffened and braced where necessary so as to be self-supporting throughout.• Paint finishing - The steel structures are completely painted using a high grade paint system. The standard colour of the series is grey for the stack, primary and secondary chambers. The front loading door comes in black.• The Primary and secondary chamber are lined with thickness of 115mm, refractory insulation that is rated at 1600°C.• All combustion fuel pipe work and electrical systems are weather proof and in accordance with BS7671-17.• 1 x Touch screen controller.
PHOENIX 2 Human CrematorSuitable for 2500-3000 cremations a year
Accessories for the human cremation range include:• Hydraulic Lift Tables• Recorders• Autoloaders• Coolers• Storm Collars
Accessories And Consumables Brochure:
Machine Requirements • Outside air inlet louvers in the room located at or below burner height, capable of passing 2500CFM of air.• 1.2m clearance between the roof and the top of the machine.
ASK FOR YOUR COPY OR DOWNLOAD AT:www.addfield.co.uk
All i
nfor
mat
ion
shou
ld b
e us
ed a
s a g
uide
onl
y, sp
ecifi
catio
ns a
re su
bjec
t to
chan
ge w
ithou
t not
ice.
Addfield Environmental Systems LimitedHollies Park | Cannock | Staffordshire | WS11 1DBwww.addfield.co.uk | [email protected] | 01543 571280
Why Addfield?
Touch ScreenIntelligent Controller
Combustion SystemThe burner system comprises of three fully automatic burners, these burners come completewith the following features:• Flame failure controls• Solenoid valves• Integral continuous air fan• Flame veri�cation sensors
Waste Loading and De-AshingThe human cremation series are designed for front loading only through the main access door.The hydraulic door is push button operated, thisfeature enables the operator to open the door tothe desired height from the control panel, animportant safety feature for busy installations. It provides better fuel e�ciency and longer refractory life.
At the end of every incineration process it isrecommended the ash should be removedprior to the next incineration cycle. A separate remains removal door is located on the rear of the unit. A stainless steel cooling pan is located on the outside of the unit to prevent �uid contamination.
Key Features:• Data logging of deceased.• Internet connectivity ideal for remote troubleshooting.• Incoming and outgoing cable terminations.• Burner control gear.• Interface relays and contactors.• Temperature indication and control of the primary chamber.• Temperature indication and control of the secondary chamber.• Plant status indicators.• Cycle status indicators.• Fault status indicators.• Touch screen operator interface.
PHOENIX 2 Human CrematorSuitable for 2500-3000 cremations a year
All i
nfor
mat
ion
shou
ld b
e us
ed a
s a g
uide
onl
y, sp
eci�
catio
ns a
re su
bjec
t to
chan
ge w
ithou
t not
ice.
We areBioSecureon all sites
Supplier toAPPCCmembers
25years of
qualityincineration
FlameVentSystem
Supply& Serviceglobally
12months
unlimited usage
warranty
MP-100 INCINERATOR
GENERAL ARRANGEMENT OFPHOENIX 2 CREMATOR
PHOENIX 2RLC
Add�eld Environmental Systems LtdUnit 17 Hollies Park CannockSta�ordshire WS11 1DP
www.add�eld.co.uk
drawn:-
scale:- Not to scale
title
drg. no. rev.
date:-
daterev. description
PHOENIX 2 Cremator
150mm concrete baseFLOOR PLAN
52
00
3800
Control panel
All information should be used as a guide only, speci�cations are subject to change without notice.
Observation hole
Clean-out door
Autoloading door
Incinerate - Cremate
2560
2896
3353
2438
Remains pan
889
1213
305
876
Access panel
2134
Door cap
SIDE ELEVATION
REAR ELEVATION
FRONT ELEVATION