Digihelic® – Going Once, Going Twice – Thrice!! The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc.

Digihelics

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Digihelics

Digihelic® – Going Once,

Going Twice – Thrice!!

The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and

current employees as a resource only. They may not be reproduced, published, or transmitted electronically for

commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within

these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc.

©Copyright 2011 Dwyer Instruments, Inc.

Page 2: Digihelics

The Digihelic® Family

Indicate

Switch

Transmit

Differential Pressure Controller

Page 3: Digihelics

Digihelic® Capabilities

Selectable Engineering Units

Pressure:

INWC PSI OZIN FTWC MMHG MMWC KPA MBAR CMWC HPA PA

0.1 or +/- 0.1 0.187 2.540 0.249 0.254 0.249 24.91

0.25 or +/- 0.25 0.144 0.467 6.350 0.623 0.635 0.623 62.28

0.5 or +/- 0.5 0.289 0.933 12.70 0.125 1.246 1.270 1.246 124.6

1 or +/- 1 0.578 1.868 25.40 0.249 2.491 2.540 2.491 249.1

2.5 or +/-2.5 1.445 0.208 4.665 63.50 0.623 6.228 6.350 6.228 622.8

5 or +/- 5 0.181 2.891 0.417 9.330 127.0 1.246 12.46 12.70 12.46 1246

10 0.361 5.781 0.833 18.66 254.0 2.491 24.91 25.40 24.91 2491

25 0.903 14.45 2.083 46.65 635.0 6.228 62.28 63.50 62.28 6228

50 1.807 28.91 4.165 93.30 1270 12.46 124.6 127.0 124.6

100 3.613 57.81 8.33 186.6 2540 24.91 249.1 254 249.1

Page 4: Digihelics

Digihelic® Capabilities

Air Velocity:

FPM, M/S

Air Flow:

SCFM, M3/HR

Selectable Engineering Units

Page 5: Digihelics

Digihelic® Capabilities

Display % of Full Scale Instead of Eng. Units

Records Peak & Valley Readings

Truly Universal Power Supply on DH & DHII

120 VAC; 240 VAC; & 24 VDC

(DH3 is 12-24VAC/VDC)

K-Factor Selection for Various Flow Sensors

Digital Damping of Display & Output

Page 6: Digihelics

Digihelic® Capabilities

4 Levels of Security

Full Scale Accuracy of 0.5%

4-20 mA Output Standard on ALL Models

4 & 20 mA Process Rescaling

Modbus® Communication on DH & DHII

2 SPDT Control Relay Outputs

Page 7: Digihelics

Digihelic® Capabilities

3 Modes of Operation

Single Set Point with Adjustable Dead Band

Dual Set Points with Adjustable Dead Bands

Single Set Point with Separate Alarm Output

LED Indication of

Set Point and Alarm

Activation

Page 8: Digihelics

Digihelic® Capabilities

Mode with Single Set Point & Separate Alarm

Selectable:

High Alarm, Low Alarm, or High/Low

Auto or Manual Reset (Via Button on Face)

Alarm Inhibit

Alarm Time Delay

Page 13: Digihelics

Markets

Air Handlers / Blowers

Semicon

Pharmaceutical / Health Care

Dust Collection / Pneumatic Conveying

Mini-Environments / Gloveboxes

Spray booths

Industrial Ovens/Furnaces

Page 14: Digihelics

Application – Industrial Blowers &

Fans

Piezo-Ring (aka Flow Ring)

Typically Offered As An Option

Maximizes Efficiency

Assists Troubleshooting

Read in CFM or DP

Page 15: Digihelics

Application - Semiconductor

Safety Exhaust

Scrubbers/Abatement

Gas Delivery Systems

Buzz-words:

CVD

ALD

Wet-processing

Gas Delivery Cabinet

Page 16: Digihelics

Semiconductor DH Feature Benefits

Communications – reduce overhead by

remotely monitoring and adjustment of plant-

wide equipment

Data Logging – quality assurance, defect

causation, and safety review

Direct flow indication – is exhaust or

process optimized?

Page 17: Digihelics

Application:

Gloveboxes & Mini-Environments

Glovebox: sealed container

that allows manipulation

of objects while being in

a different atmosphere.

Mini-Environment: no

process manipulation

component

Page 18: Digihelics

How DH is used:

Negative pressurization protect personnel

Positive pressurization protect product

Application:

Gloveboxes & Mini-Environments

Page 19: Digihelics

Application: Bio-Chem Protection

Maintain positive pressure in tents/shelters

Filter Verification

Shelter Pressure

To

tent/shelter

Page 20: Digihelics

Outside air – one of the most crucial

elements in maintaining a healthy building

environment

Codes require certain air changes/mixes

Digihelic® ensures that outside airflow is

correctly set

Application: Air Handlers

Page 21: Digihelics

Application: Air Handlers

Inexpensive air handlers do not typically include complex control packages – the DH fills this void for the OEM or BAS integrator

Why DH?

Control VFD w/4-20mA output

Remote alarm capability

True flow indication for troubleshooting fan or balancing issues

Page 22: Digihelics

Application: Air Handlers

Digihelic® provides air measurement feedback to

setpoint enabled VFDs on return and supply fans.

Alarms when flow is too low (fan problem) or too

high (closed damper).

Page 23: Digihelics

Application: Environmental

Protection

Large Scale Power Generation

Temporary/Standby Power

Page 24: Digihelics

Application: Environmental

Protection

Exhaust from power generation contains

small particulates that are particularly

hazardous to humans

These must be filtered and/or “burned-

off”

Page 25: Digihelics

Application: Environmental Protection

Thermal Oxidation: burning pollutants at

high temperature

Digihelic®

Ensures smooth flow of unclean air to thermal

oxidizer

Alarms on low/high flows

Allows data logging to comply with

environmental regulations

Page 26: Digihelics

Application: Cleanrooms

Why Upgrade Cleanroom to Digihelic®?

Monitor/control/log pressure in cleanroom

Compliance

Product Quality Issues

Clean, easy to read display

Pressure – to ensure negative pressure

Flow – to ensure minimum air changes

Page 27: Digihelics

Digihelic™ Links

Communication

Program for the

Digihelic®

For Use with

DH or DHII

Part Number: DIGIHELIC LINKS

Page 28: Digihelics

Digihelic™ Links

Communications Program

Enables Customer to Set or Change Any Parameter in the Digihelic® from a Computer

An Entire Plant of Digihelics® Can be Monitored/Controlled from A Single Location

User Can: Review an Event Log, Graph Data, Calibrate Zero & Span

Page 29: Digihelics
Page 30: Digihelics
Page 31: Digihelics
Page 32: Digihelics
Page 33: Digihelics
Page 34: Digihelics