TERMINATING SHIELDED CABLE Shielded cable has a metallic braid over the insulation to provide a barrier against electro-static interference. To obtain satisfactory result from shielded cable, the shield must be unbroken and must extend to a point as near the end of the conductor as practicable. Shielded cable is either grounded or dead-ended at each end as required by the individual installation. STRIPPING JACKET ON SHIELDED CABLE Some shielded cable has a thin extruded plastic coating over the shielding braid. Strip this off as far as necessary with a hot blade stripper. Length of sfrip depends on method of

Instalaciones avionicas

Embed Size (px)

DESCRIPTION

Avionics Installation

Citation preview

Page 1: Instalaciones avionicas

TERMINATING SHIELDED CABLE

Shielded cable has a metallic braid over the insulation to provide a barrier against electro-static interference. To obtain satisfactory result from shielded cable, the shield must be unbroken and must extend to a point as near the end of the conductor as practicable. Shielded cable is either grounded or dead-ended at each end as required by the individual installation.

STRIPPING JACKET ON SHIELDED CABLE

Some shielded cable has a thin extruded plastic coating over the shielding braid. Strip this off as far as necessary with a hot blade stripper. Length of sfrip depends on method of shield termination and type of wire connection.

Page 2: Instalaciones avionicas

If no hot blade stripper is available, use plier type hand strippers for sizes No. 22 through No. 10, and a knife for sizes larger than No. 10. Be careful not to damage shielding braid. Extruded jacket of shielded twisted wires can also be stripped by holding a soldering iron, with tip removed, against jacket, and pulling off jacket with long nose pliers as iron melts jacket.

Page 3: Instalaciones avionicas

GROUNDED SHIELD TERMINATION PROCEDURE

Page 4: Instalaciones avionicas

Cont.

Page 5: Instalaciones avionicas
Page 6: Instalaciones avionicas

UNGROUNDED (FLOATING) SHIELD TERMINATION

Page 7: Instalaciones avionicas

Cont.

Page 8: Instalaciones avionicas

TWO/PIECE GROUNDING SHEATH CONNECTOR METHOD OF SHIELD TERMINATION

Page 9: Instalaciones avionicas
Page 10: Instalaciones avionicas
Page 11: Instalaciones avionicas

Cont.MODIFIED PROCEDUREINNER FERRULE

Page 12: Instalaciones avionicas

PIGTAIL METHOD OF SHIELD TERMINATION When grounding sheath connectors and tools are not available, terminate shield for grounding by making a pigtail as follows

Page 13: Instalaciones avionicas

GROUNDING AND BONDING

One of the more important factors in the design and maintenance of aircraft electrical systems is proper bonding and grounding.

GROUNDING. Grounding is the process of electrically connecting conductive objects to either a conductive structure or some other conductive return path for the purpose of safely completing either a normal or fault circuit.

a. Types of Grounding. As a minimum, the design shoulduse three ground types: (1) ac returns, (2) Dc returns, and (3) all others.

Page 14: Instalaciones avionicas

b. Current Return Paths. The design of the ground return circuit should be given as much attention as the other leads of a circuit. A requirement for proper ground connections is that they maintain an impedance that is essentially constant.c. Heavy-Current Grounds. Power ground connections, for generators, transformer rectifiers, batteries, external power receptacles, and other heavy-current, loads mustbe attached to individual grounding brackets that are attached to aircraft structure with a proper metal-to-metal bonding attachment.

d. Current Return Paths for Internally Grounded Equipment. Power return or fault current ground connections within flammable vapor areas must be avoided.

Page 15: Instalaciones avionicas

e. Common Ground Connections. The use of common ground connections for more than one circuit or function should be avoided except where it can be shown that related malfunctions that could affect more than one circuit will not result in a hazardous condition:

(1) Redundant systems are normally provided with the objective of assuring continued safe operation in the event of failure of a single channel and must therefore be grounded at well separated points.

(2) The use of loop type grounding systems (several ground leads connected in series with a ground to structure at each end) must be avoided on redundant systems.

Page 16: Instalaciones avionicas

(3) Electrical power sources must be grounded at separate locations on the aircraft structure.

(4) Bonds to thermally or vibration-isolated structure require special consideration to avoid single ground return to primary structure.

(5) The effect of the interconnection of the circuits when ungrounded should be considered whenever a common ground connection is used. This is particularly importantwhen employing terminal junction grounding modules or other types of gang grounds that have a single attachment point.

Page 17: Instalaciones avionicas

f. Grounds for Sensitive Circuits. Special consideration should be given to grounds for sensitive circuits:

(1) Grounding of a signal circuit through a power current lead introduces power current return voltage drop into the signal circuit.

(2) Running power wires too close will cause signal interference.

(3) Separately grounding two components of a transducer system may introduce ground plane voltage variations into the system.

(4) Single point grounds for signal circuits, with such grounds being at the signal source, are often a good way to minimize the effects of EMI, lightning, and other sources of interference.

Page 18: Instalaciones avionicas

BONDING. The following bonding requirements must be considered:a. Equipment Bonding. Low-impedance paths to aircraft structure are normally required for electronic equipment to provide radio frequency return circuits and for most electrical equipment to facilitate reduction in EMI.

b. Metallic Surface Bonding. All conducting objects on the exterior of the airframe must be electrically connected to the airframe through mechanical joints, conductive hinges, or bond straps capable of conducting static charges and lightning strikes.c. Static Bonds. All isolated conducting parts inside and outside the aircraft, having an area greater than 3 in² and a linear dimension over 3 inches, that are subjected to appreciable electrostatic charging.

Page 19: Instalaciones avionicas

d. Bonding jumpers should be installed in such a manner as not to interfere in any way with the operation of movable components of the aircraft.

e. Self-tapping screws should not be used for bonding purposes. Only standard threaded screws or bolts of appropriate size should be used.

f. Exposed conducting frames or parts of electrical or electronic equipment should have a low resistance bond of less than 2.5 millohms to structure.g. Bonds should be attached directly to the basic aircraft structure rather than through other bonded parts.

h. Bonds must be installed to ensure that the structure and equipment are electrically stable and free from the hazards of lightning, static discharge, electrical shock, etc.

Page 20: Instalaciones avionicas

i. Measurements should be performed after the grounding and bonding mechanical connections are complete to determine if the measured resistance values meet the basic requirements.

Page 21: Instalaciones avionicas

j. Use appropriate washers when bonding aluminum or copper to dissimilar metallic structures so that any corrosion that may occur will be on the washer.

BONDING JUMPER INSTALLATIONS

Bonding jumpers should be made as short as practicable, and installed in such a manner that the resistance of each connection does not exceed .003 ohm.

a. Bonding Connections. To ensure a low-resistance connection, nonconducting finishes, such as paint and anodizing films, should be removed from the attachment surface to be contacted by the bonding terminal.

Page 22: Instalaciones avionicas

b. Corrosion Protection. One of the more frequent causes of failures in electrical system bonding and grounding is corrosion. Aircraft operating near salt water are particularly vulnerable to this failure mode. A suitable noncorrosive sealant, such as one conforming to MIL-S-8802, should be used to seal dissimilar metals for protection from exposure to the atmosphere.

c. Corrosion Prevention. Electrolytic action may rapidly corrode a bonding connection if suitable precautions are not taken. Aluminum alloy jumpers are recommended formost cases; however, copper jumpers should be used to bond together parts made of stainless steel, cadmium plated steel, copper, brass, or bronze. Tables 1 through 3 and figures 1 through 3 show the proper hardware combinations for making a bond connection.

Page 23: Instalaciones avionicas

TA

BL

E 1

: S

tud

bond

ing

or

grou

ndin

g to

fla

t sur

face

.

Page 24: Instalaciones avionicas

TA

BL

E 2

: P

late

nut

bon

ding

or

grou

ndin

g to

fla

t sur

face

.

Page 25: Instalaciones avionicas

TA

BL

E 3

: B

olt a

nd n

ut b

ondi

ng o

r gr

ound

ing

to f

lat s

urfa

ce.

Page 26: Instalaciones avionicas

FIGURE 1: Copper jumper connector to tubular structure.

FIGURE 2: Bonding conduit to structure.

Page 27: Instalaciones avionicas

FIG

UR

E 3

: A

lum

inum

ju

mpe

r co

nnec

tion

to

tubu

lar

stru

ctur

e.

d. Bonding Jumper Attachment. The use of solder to attach bonding jumpers should be avoided.

e. Ground Return Connection. When bonding jumpers carry substantial ground return current, the current rating of the jumper should be determined to be adequate and that a negligible voltage drop is produced.

Page 28: Instalaciones avionicas

CREEPAGE DISTANCE. Care should be used in the selection of electrical components to ensure that electrical clearance and creepage distance along surfaces betweenadjacent terminals, at different potentials, and between these terminals and adjacent ground surfaces are adequate for the voltages involved.

LIGHTNING PROTECTION FOR ANTENNAS. Antennas are mounted on exterior surfaces within lightning strike zones should be provided with a means to safely transfer lightning currents to the airframe, and to prevent hazardous surges from being conducted into the airframe via antenna cables or wire harnesses.

Page 29: Instalaciones avionicas

Ties, lacing, and straps are used to secure wire groups orbundles to provide ease of maintenance, inspection, and installation. Braided lacing tape per MIL-T-43435 is suitable for lacing and tying wires.

LACING AND TIES

In lieu of applying ties, straps meeting Specification MS17821 or MS17822 may be used in areas where the temperature does not exceed 120 C.

Straps may not be used in areas of SWAMP such as wheel wells, near wing flaps or wing folds and where they could be exposed to UV light, unless the straps are resistant to such exposure.

Page 30: Instalaciones avionicas

a. Lacing. Lace wire groups or bundles inside junction boxes or other enclosures. Single cord-lacing method, and tying tape, meeting specification MIL-T-43435, may be used for wire groups of bundles 1-inch in diameter or less:

Page 31: Instalaciones avionicas
Page 32: Instalaciones avionicas

Use the double cordlacing method on wire bundles 1-inch in diameter or larger:

Page 33: Instalaciones avionicas

b. Tying. Use wire group or bundle ties where the supports for the wire are more than 12 inches apart.

Page 34: Instalaciones avionicas

c. Plastic Ties. Plastic tie-down straps (MS3367, Type I, Class 1):

Page 35: Instalaciones avionicas

SPLICINGSplicing is permitted on wiring as long as it does not affect the reliability and the electromechanical characteristics of the wiring. Splicing of power wires, coaxial cables, multiplex bus, and large gauge wire must have approved data.

a. Splicing of electrical wire should be kept to a minimum and avoided entirely in locations subject to extreme vibrations.

b. Many types of aircraft splice connectors are available for use when splicing individual wires.

c. There should not be more than one splice in any one wire segment between any two connectors or other disconnect points.

Page 36: Instalaciones avionicas

d. Splices in bundles must be staggered so as to minimize any increase in the size of the bundle:

e. Splices should not be used within 12 inches of a termination device, except for paragraph f below.

f. Splices may be used within 12 inches of a termination device when attaching to the pigtail spare lead of a potted termination device, or to splice multiple wires to a single wire, or to adjust the wire sizes so that they are compatible with the contact crimp barrel sizes.

Page 37: Instalaciones avionicas

Connectors

Connectors provide means of quickly connecting and disconnecting wires to simplify installation and maintenance of electric and electronic equipment.

A connector set consists of two parts: a plug assembly and a receptacle assembly. The receptacle is usually the “fixed” part of the connector, attached to a wall, bulkhead or equipment case. The plug is a removable part of the connector usually attached to a cable.

When the two parts are joined, the electric circuit is made by pin-and-socket contacts inside the connector.

Page 38: Instalaciones avionicas

Many types, however crimped contacts generally used Circular type Rectangular Module blocks

Selected to provide max. degree of safety and reliability given electrical and environmental requirements

Use environmentally sealed connectors to prevent moisture penetration

Plug unused pins

The proper choice and application of connectors is a significant part of the aircraft wiring system.

Cont.

Page 39: Instalaciones avionicas

a. Circular connectors. Military Specifications cover the circular connectors most commonly used in aircraft: MIL-C-5015, MIL-C-26482, MIL-C-26500, MIL-C-38999, MIL-C-81511, MIL-C 81703, and MIL-C-83723. Connectors manufactured to these specifications have either solder type or crimp type contacts and cover a range of contact sizes from 0 to 22.

Military connector marking. Each connector is marked on the shell or coupling ring with a code of letters and numbers giving all the information necessary to identify the connector. A typical code is as follows:

Page 40: Instalaciones avionicas

MS Connector Marking

Page 41: Instalaciones avionicas

Mil Specification

Page 42: Instalaciones avionicas
Page 43: Instalaciones avionicas

Alt

erna

tive

Pos

itio

ns o

f C

onne

ctor

Ins

erts

Page 44: Instalaciones avionicas

Typical Circular Connectors

Page 45: Instalaciones avionicas

b. Rectangular Connectors. The rectangular connectors are typically used in applications where a very large number of circuits are accommodated in a single mated pair. They are available with a great variety of contacts, which can include a mix of standard, coaxial, and large power types.

c. Module Blocks. These junctions accept crimped contacts similar to those on connectors. Some use internal busing to provide a variety of circuit arrangements. They are useful where a number of wires are connected for power or signal distribution. When used as grounding modules, they save and reduce hardware installation on the aircraft. Standardized modules are available with wire end grommet seals for environmental applications and are track-mounted.

Page 46: Instalaciones avionicas

Connectors must be identified by an original identification number derived from MIL Specification (MS) or OAM specification. Several different types are shown in the next figures:

Page 47: Instalaciones avionicas
Page 48: Instalaciones avionicas
Page 49: Instalaciones avionicas

Coax cable connectors:

Page 50: Instalaciones avionicas

Coax cable connectors (cont…):

Page 51: Instalaciones avionicas

Coax cable connectors (cont…):

Page 52: Instalaciones avionicas

Coax cable connectors (cont…):

Page 53: Instalaciones avionicas

Coax cable connectors (cont…):

Page 54: Instalaciones avionicas

Environmental Classes. Environment-resistant connectors are used in applications where they will probably be subjected to fluids, vibration, thermal, mechanical shock, corrosive elements, etc.

• Firewall class connectors

• Hermetic connectors

Voltage and Current Rating. Selected connectors must be rated for continuous operation under the maximum combination of ambient temperature and circuit current load. Hermetic connectors and connectors used in circuit applications involving high-inrush currents should be derated.

Page 55: Instalaciones avionicas

SPARE CONTACTS (Future Wiring). To accommodate future wiring additions, spare contacts are normally provided. Locating the unwired contacts along the outer part of the connector facilitates future access.

A good practice is to provide: Two spares on connectors with 25 or less contacts; 4 spares on connectors with 26 to 100 contacts; and 6 spares on connectors with more than 100 contacts.

Connectors must have all available contact cavities filledwith wired or unwired contacts. Unwired contacts should be provided with a plastic grommet sealing plug.

Page 56: Instalaciones avionicas

CONNECTORS INSTALLATION

a. Redundancy. Wires that perform the same function in redundant systems must be routed through separate connectors.

b. Adjacent Locations. Mating of adjacent connectors should not be possible. In order to ensure this, adjacent connector pairs must be different in shell size, coupling means, insert arrangement, or keying arrangement.

c. Sealing. Connectors must be of a type that exclude moisture entry through the use of peripheral and interfacial seal that are compressed when the connector is mated.

Page 57: Instalaciones avionicas

e. Wire Support. A rear accessory backshell must be used on connectors that are not enclosed.

f. Slack. Sufficient wire length must be provided at connectors to ensure a proper drip loop and that there is no strain on termination after a complete replacement of the connector and its contacts.

g. Identification. Each connector should have a reference identification that is legible throughout the expected life of the aircraft.

d. Drainage. Connectors must be installed in a manner which ensures that moisture and fluids will drain out of and not into the connector when unmated.

Page 58: Instalaciones avionicas
Page 59: Instalaciones avionicas

Pin Arrangement

a, b: 115 Vac, 400 Hz, galley powerc, d: 5 Vdc, discrete weight on wheels signale, f: 28 Vdc, backup power

B

f

ed

c

b

a

A

a b

c d

f

e

C

n

j

h

i

dc

bml

k

g f

a e

Page 60: Instalaciones avionicas

Wiring Routing• Wire bundles must be routed in accessible areas that are protected from damage from personnel, cargo, and maintenance activity.

• Wiring must be clamped so that contact with equipment and structure is avoided.• Advantageous to have a number of wire groups individually tied within the wire bundle for ease of identification at a later date.

Page 61: Instalaciones avionicas

Wiring Routing, cont.

Eliminate potential for chafing against structure or other components

Position to eliminate/minimize use as handhold or support

Minimize exposure to damage by maintenance crews or shifting cargo

Avoid battery electrolytes or other corrosive fluids

Page 62: Instalaciones avionicas

Wiring Routing, cont.Route wires above fluid lines, if practical

Path of exposed end

Broken wire shall not make contact with fluid line (fail-safe concept)

Page 63: Instalaciones avionicas

Wiring Routing, cont.Use drip loops to control fluids or condensed moisture

Drainage hole in low point of tubing.

Page 64: Instalaciones avionicas

Wires improperly tied, riding on hydraulic lines, contaminated with caustic

fluid

Page 65: Instalaciones avionicas

Keep slack to allow maintenance and prevent mechanical strain

Wiring Routing, cont.

Appropriate slack

Page 66: Instalaciones avionicas

Wiring Routing, cont.

Wiring should be installed with sufficient slack so that bundles and individual wires are not under tension.

Wire groups or bundles should not exceed 1/2-inch deflection between support points.

Page 67: Instalaciones avionicas

Wiring Routing, cont.

a. Permit replacement of terminals.b. Prevent mechanical strain on wires.c. Permit shifting of equipment for maintenance purposes.

Have sufficient length to allow full travel without tension on the bundle in wires connected to movable or shock-mounted equipment or terminal lugs or connectors

Sufficient slack should be provided at each end to:

Page 68: Instalaciones avionicas

Wiring Routing, cont.Power Feeders: Easily inspected or replaced.

Special protection to prevent potential chafing

Power cables riding on structure can

cause damage to the power cables

AB

Page 69: Instalaciones avionicas

Wires Riding on Other Wires

Wire bundles that cross should be

secured together to avoid chafing

Page 70: Instalaciones avionicas

Wires Riding on Other Wires

Wire bundles that cross should be

secured together to avoid chafing

B

A

Page 71: Instalaciones avionicas

RF Cable:

Wiring Routing, cont.

a. Never kink coaxial cable.b. Never drop anything on coaxial cable.c. Never step on coaxial cable.d. Never bend coaxial cable sharply.e. Never loop coaxial cable tighter than the allowable bend radius.f. Never pull on coaxial cable except in a straight line.g. Never use coaxial cable for a handle, lean on it, or hang things on it (or any other wire).

Page 72: Instalaciones avionicas

• MOISTURE PROTECTION, WHEEL WELLS, AND LANDING GEAR AREAS:

a. Wires located on landing gear with protective tubing

b. Wires should be routed so that fluids drain away from the connectors.

• PROTECTION AGAINST PERSONNEL AND CARGO

• HEAT PRECAUTIONS

• MOVABLE CONTROLS WIRING PRECAUTIONS.

Page 73: Instalaciones avionicas

• FLAMMABLE FLUIDS AND GASES

Separation of wires from plumbing lines

Page 74: Instalaciones avionicas

CLAMPING

Wires and wire bundles must be supported by using clamps meeting Specification MS-21919 or plastic cable straps

• Constructed of materials that are compatible with their installation and environment in terms of:

Temperature, Fluid resistance, Exposure to ultraviolet (UV) light, Wire bundle mechanical loads. Spaced at intervals not exceeding 24 inches. Selected so that they have a snug fit without pinching wires.

Page 75: Instalaciones avionicas

CLAMPING, cont.

Safe angle for cable clamps

Page 76: Instalaciones avionicas

CLAMPING, cont.

Typical mounting hardware for MS-21919 cable clamps.

Page 77: Instalaciones avionicas

CLAMPING, cont.

Installing cable clamp to structure.

Page 78: Instalaciones avionicas

CLAMPING, cont.

Page 79: Instalaciones avionicas

CLAMPING, cont.

Page 80: Instalaciones avionicas

CLAMPING, cont.

Page 81: Instalaciones avionicas

Y TypeY Type Wire Bundle Breakouts

Wire bundles

Before

After

Figure 8 loop may be located before or after tail of Y

Wire bundle breakout

Head of strap shall not be located in this area or touching anything to cause chafing

Plastic mechanical strapping Before

After

Wire bundles

Page 82: Instalaciones avionicas

T TypeT Type Wire Bundle Breakouts

Plastic mechanical strapping Wire bundle

Wire bundle breakoutHead of strap shall

not be located in this area or

touching anything to cause chafing

Page 83: Instalaciones avionicas

Complex TypeWire Bundle Breakouts

Page 84: Instalaciones avionicas