Maxillary Posterior Case

4 Implants: #12 ▪ #13 ▪ #14

#19 *guide not shown in presentation

Ceramic & Open Stainless Guide Sleeves

Magnetic & Offset Open Guide Posts

3D Cone Beam Imaging

Utilizing Cosine Rule

Guide Post Bending Tool

MMEI 2.2013

Fabrication of DIAGNOSTIC guide

Holes are drilled in the cast in the planned positions of the bicuspids and first molar.

Two 3 mm guide posts and a 4 mm guide post were placed in the holes in the cast.

Three ceramic guide sleeves were used to make the initial DIAGNOSTIC guide.

DIAGNOSTIC Guide

3 mm

post & sleeve

4 mm

post & sleeve

4 mm X 20

Guide Posta

3 mm X 30

Generation ll Guide Post

3 mm X 30

Guide Post

Actual Guide Posts Used

PREview of Pre-op Corrections

# 12

NO CORRECTION

#13

LINEAR CORRECTION

2.1 mm toward the bucal + 2.1 mm toward the distal

accomplished by: 3 mm offset guide post rotated 45° disto-buccally

# 19

LINEAR CORRECTION

2 mm toward the buccal

ANGULAR CORRECTION

6.6° toward the lingual

#14

LINEAR CORRECTION

3 mm toward the palatal

PRE-OPERATIVE Evaluation

GALAXIS Cone Beam Images

A cone beam X-ray was taken and the images are viewed for each individual site

to verify or correct the position of the guide sleeve.

Panoramic views in the GALAXIS (Sirona) software are not very accurate.

Therefore, tangential & cross sectional views are used to verify the sites in next slides.

GALAXIS

#12

tangential view

cross sectional view

GALAXIS

Both views indicate #12 to be well aligned

no need to be corrected

# 13 panoramic view

middle implant highlighted in orange

GALAXIS

tangential view cross sectional view

Both views indicate the 3 mm ceramic guide sleeve should be moved to the buccal &

distal to correct the position of the proposed osteotomy.

This means: a LINEAR CORRECTION of 2.1 mm bucally and 2.1 mm distally

made by using a 3 mm offset guide post rotated 45° disto-buccally. The angle of the guide sleeve is correct. Therefore , NO ANGULAR CORRECTION.

GALAXIS # 13

Cosine is applied to determine correction data.

* see next 4 slides

Pythagorean Theorem

COSINE Calculations for Guide Right™ Guides

The cosine of 45°

is recommended for Guide Right corrections

BECAUSE

rotating the offset guide post half way

between 2 adjacent planes (90° apart) is 45°.

DéPlaque

See additional slide show: for more information

Pythagorean Theorem

COSINE Calculations for Guide Right™ Guides

dis

tal 2

.1

mm

buccal 2.1 mm

A = cosine of 45° X 3 mm offset post

(0.707 X 3 mm = 2.12 mm)

guide post center

45°

What is COSINE? See FAQ www.deplaque.com

Cosine for site #13

dis

tal 1

.8

mm

buccal 1.8 mm

A = cosine of 45° X 2.5 mm offset post

(0.707 X 2.5 mm = 1.8 mm)

guide post center

45°

Cosine EXAMPLE

dis

tal 1

.06

m

m

buccal 1.06 mm

A = cosine of 45° X 1.5 mm offset post

(0.707 X 1.5 mm = 1.06 mm)

guide post center

45°

Cosine EXAMPLE

dis

tal 1

.4

mm

buccal 1.4 mm

A = cosine of 45°X 2 mm offset post

(0.707 X 2 mm = 1.42 mm)

guide post center

45°

Cosine EXAMPLE

# 14 panoramic view

GALAXIS

A 5 X 9 mm virtual implant is placed on the cone beam image and indicates

LINEAR CORRECTION: the guide post will need to be moved 3 mm palatally

by using a 3 mm offset post with no change in the angle of the guide post.

# 14

GALAXIS

# 19 panoramic view

GALAXIS

tangential view cross sectional view

ANGULAR CORRECTION of 6.6° to the lingual will be needed

and a LINEAR CORRECTION of the guide post >

2 mm to the buccal using a 2 mm offset guide post to avoid perforation of the lingual plate.

The green line indicates the acceptable angle of the guide sleeve in the bucco-lingual plane.

GALAXIS

# 19

REview of Pre-op Corrections

# 12

NO CORRECTION

#13

LINEAR CORRECTION

2.1 mm toward the bucal + 2.1 mm toward the distal

accomplished by: 3 mm offset guide post rotated 45° disto-buccally

#14

LINEAR CORRECTION

3 mm toward the palatal

# 19 *guide not shown in presentation

LINEAR CORRECTION

2 mm toward the buccal

ANGULAR CORRECTION

6.6° toward the lingual

Fabrication of SURGICAL guide

magnetic guide posts in cast

• # 12 leave as is

• # 13 move buccally 2 mm.

• # 14 No angle correction is necessary

Magnetic guide posts with open guide sleeves

showing cleats positioned toward the palatal surface.

Triad® Gel applied to open guide sleeve cleats

& adjacent teeth to form the SURGICAL guide.

After the initial 2 mm drill a direction indicator was

placed to check the proximity to the adjacent root.

POST-OPERATIVE Evaluation

GALAXIS Cone Beam Images

# 12 volumetric view

POST OP results

GALAXIS

#13 panoramic view

GALAXIS

tangential view cross sectional view

Alignment of the #12 implant with the SURGICAL guide in place - both views.

POST-op RESULTS

#12

GALAXIS

tangential view cross sectional view

Alignment of the #13 implant with open guide sleeve - both views.

POST-op RESULTS

#13

GALAXIS

tangential view cross sectional view

Alignment of the #14 implant with guide sleeves – both views.

POST-op RESULTS

#14

GALAXIS

Post-op position of the #19 implant

Impressions were made at the time of the surgery and an X-ray

was taken of the impression copings for #12 ▪ #13 ▪ #14

to be sure they were completely seated.

A lateral view of the master cast

with prepared abutments.

Final restorations.

Final restoration.

Guide Right™

Products Used in this Presentation

(1) 3/32” drill

(2) 3 mm & (1) 4 mm Straight Guide Posts for the DIAGNOSTIC guide

(2) 3 mm & (1) 4 mm Ceramic Guide Sleeve for the DIAGNOSTIC guide

(2) 3 mm & (1) 4 mm Open Guide Sleeve for the SURGICAL guide

(1) 3 mm Straight Magnetic Guide Post

(1) 3 mm x 3 mm Offset Magnetic Guide Post

(1) 4 mm x 3 mm Offset Magnetic Guide Post

Guide Post Bending Tool & 3mm Stylus

Triad® Gel

► See slide show : Use of Pythagorean Theorem with Guide Right System

1.800.314.0065 • www.deplaque.com

A System of Components

for the fabrication and correction of diagnostic & surgical guides

in one or two dimensions

In-office or lab fabrication

Evaluate with 2D & 3D imaging

Allows linear and angular correction

Enables precision implant placement

Cost effective

1.800.314.0065 • www.deplaque.com