8 use of pythagorean theorem # 9 single implant case

Preview:

Citation preview

BEL 2.2013

Guide Right ™

Use of Pythagorean Theorem in #9 Single Implant Case

3 mm X 30 mm guide post

3 mm guide sleeve

3 mm X 1.5 mm offset guide post

3 mm open guide sleeve

Pythagorean Theorem ► Cosine

software analysis

Invivo5 Anatomage

Featuring: LINEAR CORRECTIONS

DIAGNOSTIC Guide

SURGICAL Guide

Fabrication of DIAGNOSTIC guide

Line marked on teeth to position original axis

for initial 3/32” drill mm & 3 mm guide post.

facial view

3 mm X 30 mm guide post in 3/32” hole

3 mm guide sleeve placed on the 3 mm guide post

and cast lubricated with petroleum jelly

Initial layer of Triad® Gel added to the guide sleeve cleats

and cured to stabilize the guide sleeve.

DIAGNOSTIC Guide

showing the 3 mm guide sleeve attached to the cured acrylic

ready to be placed for cone beam X-ray.

Additional and final layer of Triad® Gel

extended to lingual and incisal surfaces of adjacent teeth

PRE-OPERATIVE

Software Evaluation

Invivo5 Anatomage

axial plane

tangential plane · mesial-distal

cross sectional plane · buccal-lingual

3D volume

INITIAL EVALUATION of DIAGNOSTIC guide sleeve position

Invivo5 Anatomage

Invivo5 Anatomage

# 9

Axial Plane

The markings on the concentric

circles are 5 mm apart allowing

measurements to be calculated.

virtual implant

Yellow line passing through the axis of the implant creates the

view seen in the cross sectional view (next slide).

Greater accuracy in implant placement is achieved when the line representing

the bucco-lingual plane is set at 90° to the buccal surface of the arch.

Dragging the yellow line in the software will

change the cross sectional view as the line

rotates about the axis of the implant.

Invivo5 Anatomage # 9

preferred implant placement

axial plane

tangential plane · mesio-distal

cross sectional plane · bucco-lingual

3D Volume

Images from software evaluated in 3 planes: axial, mesio-distal & bucco-lingual

Invivo5 Anatomage

Invivo5 Anatomage

# 9

cross sectional plane · bucco-lingual

LINEAR CORRECTION

Yellow line passing through the axis of the implant.

The virtual implant is moved parallel & facial 1.3 mm

to the location of the DIAGNOSTIC guide sleeve.

# 9

virtual implant

actual guide sleeve

5 mm grid intervals

to allow measurements

to be calculated.

Invivo5 Anatomage

cross sectional view.

Illustrating preferred implant placement position (bucco-lingual)

5 mm grid intervals

to allow measurements

to be calculated.

virtual implant

Illustrating the preferred implant placement in the tangential view

The center of the virtual implant is located 1 mm mesial

to the center of the DIAGNOSTIC guide sleeve.

actual guide sleeve

Invivo5 Anatomage

LINEAR CORRECTION Illustrating preferred implant placement position (mesio-distal)

# 9

tangential view

axial plane

tangential plane · mesio-distal

cross sectional plane · bucco-lingual

3D Volume

Images from software evaluated in 3 planes: axial, mesio-distal & bucco-lingual

Invivo5 Anatomage

Invivo5 Anatomage

preferred implant placement

tangential plane · mesio-distal

Review of Pre-op Corrections

#9

LINEAR CORRECTION

Cosine is applied to determine correction data.

* see next 3 slide

1.5 mm offset guide post rotated 45º toward the mesial & facial.

Pythagorean Theorem COSINE Calculations for Guide Right™ Guides

The cosine of 45°

is recommended for Guide Right corrections

BECAUSE

rotating the offset guide post half way

between 2 adjacent planes (90° apart) is 45°.

Correction based on the calculations

from the Pythagorean Theorem

To move the position of the guide sleeve 1 mm both mesially & buccally:

► use a 1.5 mm offset guide post

► and rotate the offset guide post 45º to a mesio-buccal position.

Cosine of 45° X 1.5 mm = 0.71 X 1.5 mm = 1.06 mm

facial 1.06 mm

45°

me

sia

l 1

.06

m

m

A= cosine of 45º X 1.5

(0.707 X 1.5 mm = 1.06 mm

45°

guide post center

A= cosine of 45º X 1.5

(0.707 X 1.5 mm = 1.06 mm

Fabrication of SURGICAL guide

palatal view

1.5 mm offset guide post rotated 45º toward the mesial & facial.

Initial application of Triad® Gel

to capture the cleats on the open guide sleeve to form the SURGICAL guide.

Additional Triad® Gel added to adjacent teeth

Final SURGICAL guide

SURGICAL guide (facial view)

POST-operative RESULTS

Software Analysis Invivo5 Anatomage

# 9 POST-OP RESULTS

axial plane

tangential plane · mesio-distal

cross sectional plane · bucco-lingual

3D Volume

showing actual implant placement.

Invivo5 Anatomage

Axial Plane

The markings on the concentric

circles are 5 mm apart allowing

measurements to be calculated.

virtual implant

Yellow line passing through the axis of the implant creates the

view seen in the cross sectional view (next slide).

Greater accuracy in implant placement is achieved when the line representing

the bucco-lingual plane is set at 90° to the buccal surface of the arch.

Dragging the yellow line in the software will

change the cross sectional view as the line

rotates about the axis of the implant.

# 9 POST-OP results

Invivo5 Anatomage

Cross Section (bucco-lingual)

virtual implant

superimposed over

actual implant

actual

open guide sleeve

Yellow line passing through the axis of the implant.

5 mm grid intervals

to allow measurements

to be calculated.

# 9 POST-OP results

Only one wall of

open guide sleeve is visible.

Invivo5 Anatomage

Tangential (mesio-distal)

5 mm grid intervals

to allow measurements to

be calculated.

virtual implant

superimposed over

actual implant.

actual guide sleeve

# 9 POST-OP result

Invivo5 Anatomage

Guide Right™

Products shown in this case

1 - 3/32” drill

1 - 3 mm X 30 mm Guide Post

1- 3 mm Guide Sleeve

1 - 3 mm x 1.5 mm Offset Magnetic Guide Post

1 - 3 mm Open Guide Sleeve

Guide Post Bending Tool

Triad® Gel

1.800.314.0065 • www.deplaque.com

In-office or lab fabrication

Evaluate with 2D & 3D imaging

Allows linear and angular correction

Enables precision implant placement

Cost effective

A System of Components

for the fabrication and correction of diagnostic & surgical templates

in one or two dimensions

1.800.314.0065 • www.deplaque.com

Guide Right™ Surgical Guide System

Start With Precision. Place With Confidence.™

1.800.314.0065 • www.deplaque.com

fabricate ▪ evaluate ▪ correct ▪ verify ▪ place

DéPlaque

Recommended