Williams, Tim.EMC for product designers . Newnes, 2016 ...the Clumpany1 , 2017 Electromagnetic...

Preview:

Citation preview

2

The Heusweiler Motorway Faraday Cage

Electromagnetic Interference (EMI)

Electronic equipment must be switched off during take-off and landing…Clothing, shoes, and optical stores…

3

EMC Directive

• The ability of the system to operate without interfering with other systems

• The ability of the system to operate despite interference from other systems

• Under typical conditions (domestic, commercial, industrial)

4

5

Sources of Interference

• Supply voltage interruptions: dips, surges, and fluctuations• Transient over-voltages on supply, signal, and control lines.• Radio-frequency fields, both pulsed (radar) and continuous,

coupled directly onto equipment or onto its connected cables. • Electrostatic discharge (ESD) from a charged object or person.• Low frequency magnetic or electric fields.

6

Radio Spectrum

7

8

9

Disturbances on the Mains Supply

• An perfect power supply is not cost-effective!• Voltage variations • UK: ±10%• US: National Electric Code (NEC) recommends ±3% in households• Voltage fluctuations• Voltage interruptions• Waveform distortion• Reactive impedances and harmonic currents• Transients and surges

10

Disturbances on the Mains Supply

• Mains Signaling• Superimposed signals (3kHz-150kHz)• No extra wiring/aerial emission required• Installation can be as simple as plugging in the system components• No frequency variation from country to country or licensing issues

• ….Same frequency band as motors, power supplies, fluorescent

11

Electromagnetic Interference

Source equipment

victim equipment

peripheral

input

Case to mains cable

Common earth impedance

Common mains impedance

External mains interference

Case to caseCable to cable

ESD to interface

12

Common Impedance Coupling

System A System BInput

Inductance, L, of the wireVN

System B: input = VIN+VN

PROBLEM: VINLoad

ILOAD

System AInput

ILOAD

SOLUTION: VINLoad

System B

13

Mains Coupling

Source Victim

50Ω 50μH

Mains equivalent circuit model

System A System B

14

Magnetic Inductance

VN = -M*dIL/dtM = mutual inductance [H]M depends on… • Loop area• Loop orientation• Distance between loops• Screening material

RS

VN

INPUTLOAD

IL

MUTUAL INDUCTANCE, M

VIN

VIN VN

RS

ZIN

EQUIVALENT CIRCUIT (magnetic coupling)

15

Electric Inductance

VN = CC*dVL/dt * Zin//RSCC is the coupling capacitanceZIN//RS is victim impedance to groundCC depends on…• Distance between conductors• Their effective areas• Screening material

System A System BRS

V

LOADIL

VIN

VL RS

CC

May be stray capacitances to ground…

VIN

RS

ZIN

EQUIVALENT CIRCUIT (electric coupling)

RS

IN

16

Mutual Capacitance and Inductance

MUTUAL CAPACITANCE

MUTUAL INDUCTANCE

17

• Electric field coupling increases with increasing ZIN

• Electric coupling is more of a problem for high impedance circuits

• Magnetic field coupling decreases with increasing ZIN

• Magnetic coupling is more of a problem for low-impedance

circuits

Mutual Capacitance and Inductance

18

Radiated Couplingd [m]

E-field

V

V

E

NEAR FIELD

RADIATING SOURCE

HComplex field geometry, Ratio E/H varies with position

I

19

Radiated Couplingd [m]

E-field

V I

r [m]

H-field

V

E

NEAR FIELD

RADIATING SOURCE

HComplex field geometry, Ratio E/H varies with position

I

FAR FIELD

Plane of E-field

Plane of H-field

Ratio of E/H is constant

direction of propagation

20

Distance from source, normalized to λ/2π

Wav

e im

peda

nce,

Ω

Magnetic field predominates

Electric field predominatesNear-field impedance may be anywhere in this region

Radiated Coupling Near field; wave impedance determined by Maxwell’s equations

21

Distance from source, normalized to λ/2π

Wav

e im

peda

nce,

Ω

Magnetic field predominates

Electric field predominates

transition region

Radiated Coupling

22

Radiated Coupling Far field; plane wave. E and H decay with distance at the same rate, therefore the impedance is constant.

Distance from source, normalized to λ/2π

Wav

e im

peda

nce,

Ω

Magnetic field predominates

Electric field predominates

Plane wave, Z0 = 377 Ωtransition

region

Far-field

23

Radiated Coupling modes

24

Radiated Coupling modes

25

Radiated Coupling modes

26

Radiated Coupling modes

27

Emissions

28

Emissions

29

Electrostatic Discharge

30

Electrostatic Discharge

31

Electrostatic Discharge

32

PCB Layout and Grounding

“Ground is a low-impedance path by which current can return to its source”

33

PCB Layout and Grounding

“Ground is a low-impedance path by which current can return to its source”

34

PCB Layout and Grounding

35

PCB Layout and Grounding

36

Good Practices for EMI Immunity

• Control the flow of interference into and out of the equipment

• Keep interference paths away from critical logic circuitry

• Add I/O filters / isolation

• Use high-noise threshold logic (e.g. 74HC)

• Avoid edge triggered inputs if possible

• Use a watchdog

37

System Partitioning

38

Twisted Wires!

39

Shielded wires

40

Recommended