View
0
Download
0
Category
Preview:
Citation preview
1A101
SIM
NameElevation101
A1011
SIM
1i
CALL OUT TAG
DOOR TAG
SECTION CUT TAG
LEVEL MARKER WALL TYPE TAGCASEWORK TAG(SEE SCHEDULE IN A300)
1A101
SIM
INTERIORELEVATION TAG
EXTERIORELEVATION TAG
1
A101
NORTHARROW
CENTERLINE
Room name101
ROOM TAG(Name, Number,Square Footage)
05B
GRID LINE, GRIDBUBBLE
00 NOTE
DRAWING KEYNOTE
XX-XX
EQUIPMENT TAG(SEE SCHEDULE IN A300)
XX-X
LOCATION OFSCOPE OF WORK
BROMMEL HALL
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
54:0
8 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
COVER SHEET
G000
VIVARIUM & MARINEORGANISMS RENOVATION
PG
4/24/2013
MP
1302-13-01
1 23
SYMBOLS LEGEND
LOCATION MAP
BERNARD J. BROMMEL HALL,5500 NORTH ST. LOUIS AVE
CHICAGO, IL 60625
VIVARIUM AND MARINE ORGANISMS RENOVATION
INDEX - GENERALG000 COVER SHEETG001 WALL TYPES, ADA STANDARDS AND GENERAL NOTESG100 PARTIAL THIRD FLOOR - CODE PLANG200 CONSTRUCTION COORDINATION PLAN
INDEX - ARCHITECTURALD100 ARCHITECTURAL DEMOLITION PLANSA100 ARCHITECTURAL FLOOR PLANSA200 INTERIOR ELEVATIONSA300 CASEWORK, DOOR, EQUIPMENT & FINISH SCHEDULESA400 CONSTRUCTION DETAILS
INDEX - MECHANICALMD101 THIRD FLOOR PLAN - MECHANICAL - DEMOLITIONM101 THIRD FLOOR PLAN - MECHANICALM500 MECHANICAL DETAILSM501 MECHANICAL DETAILSM600 MECHANICAL SCHEDULES AND CONTROLS
INDEX - PLUMBINGPD100 SECOND AND THIRD FLOOR PLAN - PLUMBING - DEMOLITIONP100 SECOND FLOOR PLAN - PLUMBINGP201 THIRD FLOOR PLAN - PLUMBING
INDEX - ELECTRICALE000 ELECTRICAL COVER SHEETE101 THIRD FLOOR PLAN - ELECTICAL - DEMOLITION & LIGHTINGE201 THIRD FLOOR PLAN - ELECTIRCAL - POWER, TECHNOLOGY & SYSTEMSE301 FIRST FLOOR PLAN - ELECTRICAL - EXISTING SYSTEMSE400 ELECTRICAL SCHEDULES AND DETAILSE401 ELECTRICAL DETAILS
ABBREVIATIONSP PVC POLYVINYL CHLORIDERR R RADIUSR RBR RUBBERR RCP REFLECTED CEILING PLANR RD ROOF DRAINR REINF REINFORCEDR REQD REQUIREDR RM ROOMSS SF SQUARE FOOTS SIM SIMILIARS SOG SLAB ON GRADES SPEC SPECIFIED OR SPECIFICATIONS SPK SPRINKLERS SQ SQUARES SSTL STAINLESS STEELS STC SOUND TRANSMISSION
COEFFICIENTS STL STEELS STRUCT STRUCTURALTT T&G TONGUE & GROOVET T/ TOP OFT T/D TELEPHONE/DATAT TELE TELEPHONET TLT TOILETT TOC TOP OF CONCRETET TOS TOP OF STEEL / STRUCTURET TOW TOP OF WALLT TYP TYPICALUU UNO UNLESS NOTED OTHERWISEVV VIF VERIFY IN FIELDV VP VISION PANELWW W/ WITHW WD WOODW WWF WELDED WIRE FABRIC
ABBREVIATIONSF FIN FINISHF FLR FLOORF FND FOUNDATIONF FO FACE OFF FTG FOOTINGGG GA GAUGEG GALV GALVANIZEDG GWB GYPSUM WALL BOARDHH HC HOLLOW COREH HM HOLLOW METALH HVAC HEATING, VENTILATING, AND
AIR CONDITIONINGII INSUL INSULATION / INSULATEDI INT INTERIORI IRGWB IMPACT RESISTANT GYPSUM
WALLBOARDKK KS KNEE SPACELL LAV LAVATORYMM MATL MATERIALM MAX MAXIMUMM MECH MECHANICALM MFR MANUFACTURERM MIN MINIMUMM MO MASONRY OPENINGM MRGWB MOISTURE-RESISTANT GYPSUM
WALL BOARDM MTD MOUNTEDM MTL METALNN NIC NOT IN CONTRACTN NO NUMBERN NOM NOMINALOO OC ON CENTERO OH OPPOSITE HANDO OZ OUNCEPP PCC PRE-CAST CONCRETEP PLUMB PLUMBINGP PNT PAINT/PAINTEDP PSI POUNDS PER SQUARE INCHP PT PRESSURE TREATED
ABBREVIATIONSAA ACT ACOUSTICAL CEILING TILEA AD AREA DRAINA AFF ABOVE FINISHED FLOORA ALUM ALUMINUMA ANOD ANODIZEDA APPROX APPROXIMATEBB BSMT BASEMENTB BTTM/ BOTTOM OFCC C/C CENTER TO CENTERC CIP CAST IN PLACEC CJ CONTROL JOINTC CLG CEILINGC CLR CLEARC CMU CONCRETE MASONRY UNITC CO CLEAN OUTC COL COLUMNC CONC CONCRETEC CONST JT CONSTRUCTION JOINTC CONT CONTINUOUSC CPT CARPETC CT CERAMIC TILEDD DBL DOUBLED DEMO DEMOLISHD DIA DIAMETERD DIMS DIMENSIONSD DN DOWND DTL DETAILD DWG DRAWINGEE EA EACHE EJ EXPANSION JOINTE EL ELEVATIONE ELEC ELECTRICALE ELEV ELEVATOR / ELEVATIONE EPDM ETHYLENE PROPYLENE DIENE
ROOFINGE EQ EQUALE EXIST EXISTINGE EXT EXTERIORFF FD FLOOR DRAINF FE FIRE EXTINGUISHERF FEC FIRE EXTINGUISHER CABINETF FFE FINISHED FLOOR ELEVATION
SITE MAP SATELLITE
OWNER: NORTHEASTERN ILLINOIS UNIVERSITYNEIU PROJECT # 11-0333-0213
ISSUED FOR BID
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
3" SOUND ATTENUATED BATTINSULATION. RUN TOSTRUCTURE ABOVE.
3 5/8" MTL. STUDS AT 16" O.C.MIN. FRAME METAL STUDSAROUND UTILITIES.
SCHEDULED INTEGRAL BASE, BOTH SIDESACOUSTIC SEALANT, BOTH SIDESSCHEDULED FLOOR
DEFLECTION TRACK
5/8" FIBER REINFORCED WATERRESISTANT GYPSUM BOARD,BOTH SIDES, UP TO UNDERSIDEOF EXISTING DECK.
SCHEDULED CEILING
SEAL PENETRATIONS, VIF
BASE
PLAN
HEAD
TYPICAL METAL STUD INTERIORPARTITION WALL TOSTRUCTURE
W1_
WALL TYPE NOTES
R-VALUESTC
NA45
STUDWIDTH
UL NA
W1A 3-5/8" 4-7/8"
OPEN CELL CONTINUOUSSPRAYFOAM INSULATION
2 1/2" MTL. STUDS AT 16" O.C.MIN. FRAME METAL STUDSAROUND UTILITIES.
SCHEDULED INTEGRAL BASEACOUSTIC SEALANTSCHEDULED FLOOR
5/8" FIBER REINFORCED WATERRESISTANT GYPSUM BOARD TOUNDERSIDE OF EXISTING DECK.SEE SPEC 092900, 2.3B.
SCHEDULED CEILING
SEAL PENETRATIONS, VIF
BASE
PLAN
HEAD
TYPICAL METAL STUD FURRING WALL, NOTTO STRUCTURE
W2_
WALL TYPE NOTES
R-VALUESTC
R 1345
STUDWIDTH
UL
W2A 2 1/2" 3-1/8"
ACOUSTICAL SEALANT, BOTHSIDES
EXISTING WALL, TOREMAIN
NA
W2B 2 1/2" 3-1/8" CHASE WALL. NO FOAM INSULATION.
ACOUSTIC SEALANT
EXISTING ROOF DECK, VIF
WALLTHICKNESS
WALLTHICKNESS
EXISTING ROOF DECK, VIF
SEALANT AND BACKER ROD WHEREEXISTING WALL AND EXISTING DECKMEETS. VIF
PROVIDE BACKING PLATES AS INDICATED ON THEDRAWINGS OR WHERE NOT INDICATED, ACCORDINGTO THE FOLLOWING SCHEDULE. REFER TO DETAILSELSEWHERE IN THE SET OF DRAWINGS FOR THESUPPORT OF WALL MOUNTED ITEMS IN EXCESS OF150 POUNDS.
BACKING PLATE: 16 GAGE x 12" HIGHCONTINUOUS METAL PLATE
20 GAGE STUDS AT BACKINGPLATES, TYPICAL.
THREE 3/4" #10 LOW PROFILE PAN HEAD SHEET METALSCREWS AT EACH STUD, TYPICAL
TYPE 'A' BACKING PLATES:- AT DOOR STOPS.- AT ALL UPPER WALL HUNG CABINETS (2) TWO MIN AT FURRED OUT WALLS.- AT ALL BASE CABINETS IN FURRED OUT WALLS.- AT ALL FIXED WALL MOUNTED EQUIPMENT.- AT ALL FULL HEIGHT CABINETS IN FURRED OUT WALLS.- AT WASH DOWN PLUMBING HOSE.
STANDARD MOUNTING HEIGHTS
MANEUVERING CLEARANCES AT DOORSNTS
SHELVESSWITCH AT DOORSCALE: 1/4"=1'-0"
1'-0"
18"
5'-0"
4'-0"Y
2'-0"
YY
2'-0"
Y
X
4'-6"
MAX
HT.
FOR
ACCE
SSIB
LEST
ORAG
E SP
ACES
1'-9" MAX. FROM CENTERLINE OF SHELF
9" M
IN
4'-0"
MAX
.
1'-6"
MIN
.
1'-10" MIN.
8" MAX4'-
0"
MIN.
W/ LATCH AND CLOSER
SWITCHLIGHT
PULL SIDE PUSH SIDE
OUTLETS
MIN.
PULL SIDE
X = 36" MIN. IF Y = 60"X = 42" MIN. IF Y = 54"
PULL SIDE
Y = 4'-0" MIN. Y = 4'-6" MIN. IFDOOR HAS BOTH A LATCH AND A CLOSER
PUSH SIDE PUSH SIDE
Y = 3'-6" MIN. Y = 4'-0" MIN. IFDOOR HAS BOTH A LATCH AND A CLOSER
Y = 3'-6" MIN. Y = 4'-0" MIN. IFDOOR AS A CLOSER
FORWARD REACH IS SHOWN, U.N.O.
4'-0"
MAX
TO
HIGH
EST
POIN
T OF
OPE
RATI
ON
GROUND & FLOOR SURFACES
1/4" M
AX.
1/2" M
AX.
1
2
SCALE: 12" = 1'-0"SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0"
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
16:1
5 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
WALL TYPES, ADA STANDARDSAND GENERAL NOTES
G001
VIVARIUM & MARINEORGANISMS RENOVATION
AJL
4/24/2013
MP
1302-13-01
2 23 1 1/2" = 1'-0"ASSEMBLY TYPES
10 6" 1'
SHEET NOTES - ASSEMBLY TYPES
1 PARTITIONS AND FURRING ARE DIMENSIONED TO THE FACE OF PARTITION ASSEMBLY(NOT TO THE FACE OF APPLIED FINISH OR FACE OF STUD), UNLESS OTHERWISE NOTED.
2. PARTITION TYPE INDICATIONS ARE INDEPENDENT OF APPLIED FINISHES. SEE FINISHSCHEDULE AND/OR THE DESIGNATIONS ON THE PLANS FOR ADDITIONAL INFORMATIONREGARDING APPLIED FINISHES.
3 WHERE PARTITION TYPE DESIGNATION ON FLOOR PLAN IS INTERRUPTED BY DOOROPENING, GLAZED PARTITION, ETC., CONSTRUCTION ABOVE INTERRUPTION (ANDWHERE APPLICABLE BELOW) IS TO BE THE SAME AS THAT DESIGNATED FOR THEPARTITION IN WHICH THE INTERRUPTION OCCURRED.
4 SEAL PERIMETER OF SOUND RATED PARTITIONS WITH CONT BEAD OF ACOUSTICALSEALANT. CLOSE ALL GAPS THROUGH OR AROUND PARTITION BY SEALING ALL JOINTS,GAPS AROUND OUTLET BOXES AND PENETRATIONS, INCLUDING THOSE ABOVE FINISHCEILINGS. ISOLATE PARTITION FROM ALL PIPE AND DUCT PENETRATIONS BY STOPPINGGYPSUM BOARD ½” MIN TO 3/4” MAX FROM PIPE OR DUCT. SEAL GAP BETWEEN GYPSUMBOARD AND PIPES/DUCTS WITH BACKER ROD AND ACOUSTICAL SEALANT
5 PROVIDE ACOUSTICAL OUTLET BOX PADS AT ALL FIRE RATED & SOUND RATEDPARTITIONS AT ALL ELECTRICAL, TELEPHONE AND DATA OUTLET BOXES AS WELL AS ATALL WITCH BOXES, MOLD PAD CAREFULLY AROUND BOX AFTER BOX IS SECURELYATTACHED TO STUD BEFORE GYPSUM BOARD IS INSTALLED. SEAL ALL OPENINGS WITHOUTLET BOX SEALANT MATERIAL.
6 PROVIDE CONTINUOUS BACKING PLATE OF TYPE AND AT HEIGHT(S) ABOVE FINISHFLOOR AS REQUIRED. CONTINUOUS BACKING PLATE RUNS ONE STUD MINIMUM BEYONDITEM OR EQUIPMENT ANCHORS, REFER TO BACKING PLATE SCHEDULE THIS SHEET.
7 HEAD DETAILS TARGETED REFER TO EXISTING STRUCTURE. THE EXISTING STRUCTUREINCLUDES: CONCRETE FLOOR SLABS, STRUCTURAL GLAZED BRICK WALL, VIF.
8 ADDITIONALLY PROVIDE 20 GAUGE METAL STUD WALL FRAMING AT THE FOLLOWINGLOCATIONS: a) DOUBLE STUD JAMB ASSEMBLIES AT OPENINGS; b) FIRST STUD IN THEPARTITION BEYOND THE DOUBLE STUD JAMB ASSEMBLY. LOCATE STUD 6" FROMDOUBLE STUD ASSEMBLY; c) STUDS TO WHICH REINFORCING GYPSUM WALL PANELSARE ATTACHED; d) STUDS TO WHICH WALL MOUNTED EQUIPMENT--INCLUDING OWERFURNISHED EQUIPMENT--IS FASTENED TO; e) STUDS INSTALLED FOR OPENING HEADSBETWEEN DOUBLE STUD JAMB ASSEMBLIES
1 1/2" = 1'-0"TYPICAL - BACKING PLATE DETAIL
20 6" 1'
SHEET NOTES - ARCHITECTURAL GENERAL NOTES
6 THE ARCH DWGS ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND EXACTLOCATION OF ALL EXPOSED ELEMENTS OF THE WORK, INCLUDING THAT WORK WHICH ISILLUSTRATED PRIMARILY ON DWGS OF OTHER DISCIPLINES. LOCATIONS SHOWN ON OTHERDWGS ARE SCHEMATIC, UNLESS OTHERWISE NOTED ON THE ARCH DWGS. THE ARCH DWGSTAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL PARTSOF THE WORK. EXCEPTION: DIMENSIONED LOCATIONS SHOWN ON DRAWINGS OF OTHERDWGS ARE SCHEMATIC, UNLESS OTHERWISE NOTED ON THE ARCH DWGS. THE ARCH DWGSTAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL PARTSOF THE WORK. EXCEPTION: DIMENSIONED LOCATIONS SHOWN ON DRAWINGS OF OTHERDISCIPLINES SHALL GOVERN ONLY WHERE:a) SPECIFICALLY AND INDIVIDUALLY INDICATED BY SYMBOL, KEYED NOTE, OR NOTATIONON THE ARCHITECTURAL DRAWINGS.b) OCCURING WITHIN A ROOM OR OTHER IDENTIFIED SPACE FOR WHICH ARCH SHEET ORSCHEDULE NOTES INDICATE THAT DIMENSIONS PROVIDED ELSEWHERE SHALL GOVERN.c) THE ARCH FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND ELEVATIONSSHOW THE EXACT LOCATION OF MANY – BUT NOT ALL – EXPOSED PARTS OF THE WORK. FORITEMS NOT LOCATED EXACTLY, CONSULT THE ARCHITECT.d) REFER TO THE, MECHANICAL, ELECTRICAL, PLUMBING DWGS FOR THE DETAILED DESIGNOF THE MECHANICAL, ELECTRICAL, PLUMBING SYSTEMS AND FIRE PROTECTION OF WHICHPORTIONS ALSO MAY BE SHOWN ON THE ARCHITECTURAL DRAWINGS.e) REFERENCES TO M/E/P DRAWINGS REFER TO THE MECHANICAL, ELECTRICAL ANDPLUMBING DRAWINGS. REFER TO THE SHEET INDEX G000.f) DIMENSIONS SHALL GOVERN, DO NOT SCALE THE DRAWINGS. WHERE THERE APPEARSTO BE A CONFLICT BETWEEN DIMENSIONS OR WHERE DIMENSIONS CANNOT BE DETERMINEDFROM THE DRAWINGS, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.g) UNLESS SHOWN OTHERWISE, ALL DOORS SHALL BE LOCATED SUCH THAT THERE IS A 2INCH WALL RETURN BETWEEN THE JAMB FRAME AND THE ADJACENT PERPENDICULAR WALLh) PROVIDE CONTROL JOINTS IN DRYWALL PARTITIONS AND CEILINGS AS SHOWN OR IFNOT SHOWN AT DOOR FRAMES, UPWARD FROM BOTH JAMB CORNERS, WHERE THE GYPSUMBOARD ABUTS A DISSIMILAR CONSTRUCTION, OR THE DIMENSIONS OF THE GYPSUM BOARDEXCEED 30 FEET IN THE SAME PLANE.
SHEET NOTES - ARCHITECTURAL GENERAL NOTES
1 THE FOLLOWING GENERAL NOTES APPLY TO ALL ARCHITECTURAL DRAWINGS2 FOR NOTES APPLICABLE TO THE SCOPE OR WORK INDICATED ON INDIVIDUAL SHEETS, REFER
TO SHEET NOTES ON THAT SHEET3 FOR GENERAL NOTES AND SYMBOLS APPLICABLE ONLY TO THE DRAWINGS OF DISCIPLINES
OTHER THAN ARCHITECTURE, REFER TO THE SPECIFIC DRAWINGS OF THAT DISCIPLINE – SEE“INDEX OF DRAWINGS” ON THE COVER SHEET.
4 THE ARCH DWGS ARE PART OF A LARGER SET OF DRAWINGS WHICH, WHEN COMPLETE,CONSIST OF ALL DRAWINGS LISTED BY THE INDEX OF DWGS. THE WORK DESCRIBED BY THEDWGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON DWGS OFANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO DWGS OF ANOTHER DISCIPLINE.PARTIAL SETS OF DWGS ARE INCOMPLETE AND SHALL NOT BE DISTRIBUTED AND UTILIZED BYTHE CONTRACTOR. IT IS THE CONTRACTOR’S RESPONSIBILITY TO REVIEW AND COORDINATETHE WORK OF ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH THE REQUIREMENTSOF THE CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURETHAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THEREQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS.
5 THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALLSUBCONTRACTORS, TRADES, AND SUPPIERS. THE CONTRACTOR SHALL ENDEAVOR TOIDENTIFY AND NOTIFY THE ARCHITECT OF ANY CONFLICTS BETWEEN THE WORK OFDIFFERENT PARTIES AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE ANDADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WTIHOUT DELAYING THE WORK. ALLDEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BEAPPROVED IN ADVACE BY THE ARCHITECT.
SHEET NOTES - GENERAL PROJECT NOTES
1 THE FOLLOWING GENERAL PROJECT NOTES APPLY TO ALL DRAWINGS AND TRADESOF WORK.
2 REFER TO DRAWINGS OF OTHER DISCIPLINES FOR ADDITIONAL INFORMATION ANDCOORDINATION OF THE WORK.
3 DETAILS SHOWN ARE INDICATIVE OF THE CHARACTER, PROFILES MATERIAL ANDSYSTEMS REQUIRED FOR THE WORK INCLUDING THOSE CONDITIONS NOT COVEREDBY SPECIFIC DETAILS.
4 WHERE THE DESIGN INTENT CANNOT BE DETERMINED FROM THE DRAWINGS ORSPECIFICATIONS, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
5 CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTINGCONDITIONS PRIOR TO COMMENCING THE WORK. EXISTING CONDITIONS SHOWN AREFROM INFORMATION PROVIDED BY THE OWNER. CONTRACTOR SHALL VERIFY INFIELD ALL EXISTING CONDITIONS, DIMENSIONS, ELEVATION HEIGHTS, CONSTRUCTIONAND BUILDING SYSTEMS PRIOR TO PROCEEDING WITH THE WORK.
6 THE OWNER HAS IDENTIFIED ASBESTOS CONTAINING MATERIALS ON SITE. OBTAIN ACOPY OF THE OWNER’S HAZARDOUS MATERIALS SURVEY REPORT PRIOR TOCOMMENCING THE WORK. OWNER TO REMOVE THE MATERIALS PRIOR TO THE WORK.NOTIFY THE OWNER IMMEDIATELY IF ADDITIONAL HAZARDOUS MATERIALS AREIDENTIFIED. DO NOT PROCEED WITH THE WORK UNTIL THE HAZARDOUS MATERIALSHAVE BEEN REMOVED.
7 PREPARE EXISTING FLOOR SURFACE AND EXISTING INTEGRAL BASE FOR NEW,SCHEDULED FLOORING AND BASES. FILL ALL FLOOR OPENINGS AND DEPRESSIONSWITH MATERIALS AND METHOSD ACCEPTABLE TO NEW FLOORING MANUFACTURER.SEE SPEC SECTION 096700 FLUID APPLIED FLOORING.
8 THE GENERAL CONTRACTOR SHALL COORDINATE THE WORK WITH WORKPERFORMED BY THE OWNER UNDER SEPARATE CONTRACTS. THIS SHALL INCLUDE,BUT NOT BE LIMITED TO THE OWNER’S FURNITURE AND LAB EQUIPMENT.
9 THE CONTRACTOR IS RESPONSIBLE FOR THE TIMELY REMOVAL OF ALL DEMOLITIONDEBRIS AND PROTECTION OF EXISTING AREA WHICH ARE NOT AFFECTED BY THESCOPE OF WORK. ANY DAMAGE TO THE PREMISES SHALL BE BROUGHT BACK TOORIGINAL CONDITION AT THE COST OF THE GENERAL CONTRACTOR.
10 GENERAL CONTRACTOR TO BE RESPONSIBLE FOR PROTECTING EXISTING WALL,CEILING AND FLOOR FINISHES DURING CONSTRUCTION NOT SHOWN TO BEREMOVED.
1/4" = 1'-0"00 ADA STANDARDS
30 2' 4' 8'
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
1-HOUR
EGRESS PATH
EXIT
ARE OUTSIDE THE EXTENTOF INTERIOR FINISH WORK
EXISTING EXIT LIGHT
EXISTING WALL MOUNTEDFIRE EXTINGUISHER
PSYCHMARINE
DIAGONISTICLAB327
PSYCHMARINE
HOUSING333
ANIMALHOUSING 1
335 A
ANIMALHOUSING 2
335 B
PROCEDURELAB335
EXIT WIDTH 36 INCHES
TRAVEL DISTANCE: 129'-0"IS LESS THAN 150'-0"
3' - 10 5/8"
CHICAGO BUILDING CODE TABLE 6(13-60-100)CONSTRUCTION: EXISTING TYPE I-B (ASSUMED)
STRUCTURAL FRAME 3 HRSFLOOR CONSTRUCTION 2 HRSROOF CONSTRUCTION 2 HRSBEARING WALLS N/ANON BEARING INT. WALLS PER CODEVERTICAL SHAFTS < 4 STORIES 1 HRFLOOR & ROOF OPENINGS 1 HRCORRIDORS 1 HR
STORIES: 3 FLOORS AND PENTHOUSE, NOT SPRINKLERED
THIRD FLOOR AREA: 42, 278 SF
CONSTRUCTION: CONCRETE SUPER STRUCTURE, CONCRETE DECKS (EXISTING)
CONSTRUCTION TYPE: EXISTING TYPE I-B (ASSUMED)
EXIT ACCESSREQUIRED: 150 FT (NON-SPRINKLERED)ACTUAL: 156 FT (NON-SPRINKLERED)*
*NOTE: TRAVEL DISTANCE DOES NOT MEET CHICAGO BUILDINGCODE
AREA OF RENOVATION: 737 SF
OCCUPANCY: CLASS C3, TYPE II SCHOOL, COLLEGE
CONSTRUCTION TYPE: EXISTING I-B ASSUMED
PROJECT AREA
CODE PLAN LEGEND
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
16:2
0 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
PARTIAL THIRD FLOOR - CODEPLAN
G100
VIVARIUM & MARINEORGANISMS RENOVATION
AJL
4/24/2013
MP
1302-13-01
3 23
3/32" = 1'-0"THIRD FLOOR CODE PLAN
1
APPLICABLE BUILDING CODESBUILDING CHICAGO BUILDING CODE, 2012
MECHANICAL INTERNATIONAL MECHANICAL CODE (IMC) 2012MECHANICAL ASHRAE 90.1-2012MECHANICAL ASHRAE 62.1
ELECTRICAL CHICAGO ELECTRICAL CODE, LATEST EDITIONELECTRICAL NATIONAL ELECTRICAL CODE (NEC) 2011ELECTRICAL UNDERWRITER'S LABORATORYELECTRICAL NATIONAL ELECTRICAL MANUFACTURERS (NEMA)ELECTRICAL INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE)ELECTRICAL ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA)
PLUMBING INTERNATIONAL PLUMBING CODE (IPC) 2012PLUMBING STATE OF ILLINOIS PLUMBING CODE 2004
ENERGY ILLINOIS ENERGY CONSERVATION CODEENERGY INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2012
ACCESSIBILITY CHICAGO BUILDING CODE, CHAPTER 18 ACCESSIBILITYACCESSIBILITY AMERICANS WITH DISABILITIES ACT (ADA) STANDARD FOR ACCESSIBLE DESIGN
2010
LIFE SAFETY LIFE SAFETY CODE (NFPA101)LIFE SAFETY NATIONAL INSTITUTE OF HEALTH 9NIH) , GUIDE FOR THE CARE AND USE OF
LABORATORY ANIMALS, 8TH EDITION
FIRE RESISTANCE RATING REQUIREMENTS
EXISTING BUILDING SUMMARY
TRAVEL DISTANCE
PROJECT CODE DATA
ROOM AREA SCHEDULE
NUMB
ER
ROOM NAME AREA OCCU
PANC
Y
OCCU
PANT
S
327 PSYCH MARINE DIAGONISTIC LAB 219 SF 30SF / PERSON 7333 PSYCH MARINE HOUSING 155 SF 30SF / PERSON 5335 PROCEDURE LAB 261 SF 30SF / PERSON 8
335 A ANIMAL HOUSING 1 51 SF 30SF / PERSON 1335 B ANIMAL HOUSING 2 51 SF 30SF / PERSON 1
Grand total 737 SF 22
0 8' 16'
KEY PLAN - THIRD FLOOR
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
1 2 3 4 5 6 7
A
B
9 10 11
C
D
9'8'8 12 13 14 15 16 17 18 19 20
E
F
G
H
J
K
M
N
P
R
S
T
U
V
W
X
STAIR PROJECT AREA ELEVATOR STAIR TOILETSRECEIVING AREA IN FIRSTFLOOR BELOW, REFER TO E301
PROJECT AREA
3 4 5 6
A
CLASSROOM229 CLASSROOM
235
STUDENT CENTER237
0912 091209122 3 4 5
E
F
G
H
MECHANICALEQUIPMENT
403
23042304
23042304
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
16:2
5 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
CONSTRUCTION COORDINATIONPLAN
G200
VIVARIUM & MARINEORGANISMS RENOVATION
PG
4/24/2013
MP
1302-13-01
4 23
1/16" = 1'-0"THIRD FLOOR OVERALL PLAN FOR COORDINATION
10 8' 16' 32'
KEY PLAN - THIRD FLOOR
RFER TO SHEET A100 FOR FLOOR PLAN LEGEND AND REFLECTED CEILING FILE LEGEND
1/4" = 1'-0"SECOND FLOOR REFLECTED CEILING DEMO PLAN
2 1/8" = 1'-0"PENTHOUSE PLAN FOR COORDINATION ONLY
3
SHEET KEYNOTES0912 TEMPORARILY REMOVE AND SALVAGE EXISTING 2ND FLOOR CEILING TILES AND REMOVE
EXISTING PLUMBING WORK AS SHOWN ON PD100. INSTALL NEW PLUMBING WORK AS SHOWNIN P100. PROTECT EXISTING SURROUNDING PLUMBING, FIXTURES, FINISHES, EQUIPMENT,FURNISHINGS DURING REMOVAL. RE-INSTALL EXISTING CEILING TILES AFTER REMOVAL.PATCH, CLEAN AND REPAIR ANY DAMAGE TO THE EXISTING SPACE.
2304 PENTHOUSE- SEE MECHANICAL DRAWING FOR CONNECTION TO EXSITING AHU.
0 2' 4' 8'0 4' 8' 16'
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
EXISTING WALL TO BE DEMOLISHED
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
EXISTING DOOR AND FRAME TO BEDEMOLISHED
EXISTING TO BE DEMOLISHED
INDICATES EXTENT OF DEMOLITION WORKREQUIRED BY KEYNOTE THROUGHOUT ROOMOR SPACE
AREA OUTSIDE THE EXTENT OF INTERIOR FINISHWORK
3 4 5 6
A
B
389 SF
BIO ANIMALLABS335
382 SF
PSYCHMARINE LAB
333
PSYCHMARINE LAB
327
0201
0201
0202 0203
0204
0205
0206
0207
02070209
0209
0210
0210
0211
02050203
0218
0213
0217
0217
0216 0203
0215
0205
0213
0224
0215
02250225
0229
0226
0226
0227
0228
CORRIDOR383
GREENHOUSE345
0214
0203 0203
0243 0243
02440244
0244
0243
0208
0219
024602460246
0221
0241
3 4 5 6
A
B
BIO ANIMALLABS335
PSYCHMARINE LAB
333
PSYCHMARINE LAB
327
0222
0222
0222
H
H
H
0231
02300235 0235 0235
CORRIDOR383
GREENHOUSE345
0245
3 4 5
A
0212
0231
02330233
0234
0242
0242
0212
0230
0220
EXISTING LIGHT FIXTURE TO BE REMOVED; REF. TOELECTRICAL PLANS
EXISTING MECH. SUPPLY DIFFUSER TO BE REMOVED;REF. MECHANICAL PLANS
EXISTING MECH. RETURN DIFFUSER TO BE REMOVED; REF.MECHANICAL PLANS
INDICATES EXTENT OF DEMOLITION WORKREQUIRED BY KEYNOTE THROUGHOUT ROOMOR SPACE
H EXISTING HEAT DETECTOR TO BE REMOVED.
AREA OUTSIDE THE EXTENT OF INTERIOR FINISHWORK
PROJECT AREA
DEMOLITION PLAN LEGEND
1/4" = 1'-0"DEMOLITION PLAN
1
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
16:1
0 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
ARCHITECTURAL DEMOLITIONPLANS
D100
VIVARIUM & MARINEORGANISMS RENOVATION
PG
4/24/2013
MP
1302-13-01
5 230 2' 4' 8'
SHEET KEYNOTES0201 REMOVE EXISTING CIRCADIAN BOX BY NEIU0202 REMOVE EXISTING FAUCET0203 EXISTING FLOOR DRAIN TO REMAIN0204 REMOVE RAISED FLOOR PLATFORM. SCAN THE PLATFORM FOR PIPES AND CONDUITS BEFORE
DEMOLITION0205 REMOVE EXISTING SINK - SEE PLUMBING DRAWINGS.0206 REMOVE EXISTING LAB DRYING BOARD0207 REMOVE AND SALVAGE EXISTING STORAGE UNIT BY NEIU0208 SAWCUT AND REMOVE EXISTING STRUCTURAL GLAZED FACING TILE WALL FOR NEW DOOR
OPENING.0209 REMOVE AND RE-INSTALL EXISTING MOBILE METAL TABLE BY NEIU0210 REMOVE AND RELOCATE EXISTING 6' X 2' METAL RACK BY NEIU0211 REMOVE AND SALVAGE EXISTING COMPUTER BOX BY NEIU0212 EXISTING GREEN HOUSE ENCLOSURE. TO REMAIN.0213 REMOVE AND SALVAGE EXISTING TABLE BY NEIU0214 REMOVE, SALVAGE AND REINSTALL EXISTING WALL-MOUNTED EYEWASH0215 REMOVE AND RE-INSTALL EXISTING CABINET BY NEIU0216 REMOVE EXISTING RACK BY NEIU0217 REMOVE AND RE-INSTALL EXISTING FISH TANK & RACK BY NEIU0218 REMOVE AND RE-INSTALL EXISTING FRIDGE BY NEIU0219 REMOVE PORTION OF WALL FOR NEW DUCT WORK. SEE MECHANICAL DRAWINGS.0220 CUT ROOF TO ACCOMODATE NEW ROOF THROUGH PLUMBING VENT, SEE PLUMBING.0221 SAW CUT STRUCTURAL GLAZED FACING TILE WALL, TO ACCOMODATE COLD WATER FEEDER FOR
FISH TANKS, SEE PLUMBING.0222 REMOVE EXISTING FINISH CEILING, CEILING SOFFITS, CEILING DEVICES AND FIXTURES0224 REMOVE EXISTING CASEWORK. REMOVE AND SALVAGE EXISTING STAINLESS STEEL
COUNTERTOP FOR NEW WORK.0225 REMOVE AND RE-INSTALL EXISTING FARADAY BOX BY NEIU0226 REMOVE AND RE-INSTALL EXISTING TABLE BY NEIU0227 REMOVE AND RE-INSTALL EXISTING TOOLBOX BY NEIU0228 REMOVE AND RE-INSTALL EXISTING CRYO BY NEIU0229 REMOVE AND RE-INSTALL EXISTING COMPUTER BY NEIU0230 EXISTING GREEN HOUSE0231 REMOVE COVER ONLY OF EXISTING ROOF HATCH. HATCH FRAME OPENING AND CAP FLASHING
TO REMAIN.0233 EXISTING VENTS TO REMAIN0234 REMOVE EXISTING ROOF EXHAUST, SEE MECHANICAL0235 REMOVE EXISTING WALL-MOUNTED HW, CW, A & S TO MAIN AND CAP, SEE PLUMBING DRAWINGS.0241 EXISTING HM DOOR AND FRAME TO REMAIN0242 EXISTING ROOF TO REMAIN, TYPICAL0243 REMOVE EXISTING DOOR, EXISTING FRAME TO REMAIN0244 REMOVE EXISTING FLOOR FINISH AND PREP IT TO TAKE NEW FLOOR FINISH, TYPICAL.0245 TEMPORARILY REMOVE AND SALVAGE EXISTING CEILING GRID AND TILES TO ACCOMODATE
MECHANICAL WORK. INSTALL NEW MECHANICAL WORK. PROTECT EXISTING FIXTURES, FINISHES,EQUIPMENT, FURNISHING DURING REMOVAL. RE-INSTALL EXISTING CEILING TILES. PATCH, CLEANAND REPAIR ANY DAMAGE TO THE EXISTING SPACE. SEE MECHANICAL DRAWINGS.
0246 REMOVE EXISTING WALL MOUNTED FIXTURES, EXISTING WIREMOLD AND EXISTING OUTLETS,TYPICAL - SEE ELECTRICAL, AND MECHANICAL DRAWINGS.
1/4" = 1'-0"DEMOLITION REFLECTED CEILING PLAN
20 2' 4' 8'
1/4" = 1'-0"DEMOLITION ROOF PLAN
3
DEMOLITION RCP LEGEND
0 2' 4' 8'
SHEET NOTES - DEMOLITION
10 CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS DAILY. DEMOLITION WORK SHALL REMAINSAFE & CLEAN FOR THE BUILDING’S OCCUPANTS & CONSTRUCTION WORKERS. OCCUPIED AREASADJACENT TO THE PROJECT WORK AREAS SHALL BE KEPT CLEAN AT ALL TIMES DURING THE WORK.
11 REMOVE CEILINGS & ASSOCIATED HANGERS AND SUPPORTS IN LOCATIONS TO RECEIVE NEWCEILINGS. SEE THE FINISH SCHEDULE & THE REFLECTED CEILING PLANS.
12 THE CONTRACTOR SHALL PROVIDE TEMPORARY PROTECTION, SUPPORT, BRACING SEALING ANDCAPPING OF EXISTING PARTITIONS, CEILINGS, PIPES, DUCTS, CONDUITS, ETC., SHOWN TO BEPARTIALLY DEMOLISHED. THE TEMPORARY WORK SHALL KEEP THE PARTIALLY DEMOLISHED WORKSTABILIZED. WHERE EXISTING CONSTRUCTION IS SHOWN TO BE PARTIALLY DEMOLISHED, EXTENDDEMOLITION A MINIMAL DISTANCE AS REQUIRED TO INSTALL NEW WORK INDICATED.
SHEET NOTES - DEMOLITION
7 PROTECT EXISTING INTERIOR WALLS DURING REMOVAL AND CONSTRUCTION. PROVIDETEMPORARY PROTECTION FROM DUST, NOISE, DAMAGE, ETC. AND CONSTRUCTION BARRIERS ANDOTHER SITE PROTECTION REQUIREMENTS CONSISTENT WITH THE SPECIFICATIONS SECTION, ANDDIVISION 1, GENERAL REQUIREMENTS.
8 PLANS ARE DIAGRAMMATIC AND PROVIDED TO SHOW INTENT ONLY. UNLESS SPECIFICALLY NOTEDOTHERWISE ALL PARTITION ASSEMBLIES INDICATED TO BE DEMOLISHED SHALL BE DEMOLISHEDCOMPLETELY, INCLUDING PLASTER, MASONRY, GWB, STUDS, TRACKS FASTENING DEVICES, AND ALLRELATED PARTS.
9 SALVAGED MATERIALS INDICATED ARE PROPERTY OF THE OWNER. TEMPORARILY STOREMATERIALS ON SITE AS DIRECTED BY THE OWNER. PROVIDE ALL NECESSARY PROTECTION AGAINSTMOISTURE, IMPACT, AND AN6Y OTHER TYPE OF POTENTIAL DAMAGE.
SHEET NOTES - DEMOLITION
1. CONTRACTOR SHALL VISIT THE SITE AND BECOME GENERALLY FAMILIAR WITH THE EXISTINGCONDITIONS PRIOR TO COMMENCING THE WORK.
2. CONTRACTOR SHALL NOTIFY THE OWNER OF ANY AND ALL DISCREPANCIES BETWEEN THEDEMOLITION DRAWINGS AND SPECIFICATIONS AND ACTUAL CONDITIONS PRIOR TO PROCEEDINGWITH THE WORK.
3. REFER TO M/E/P AND FP DEMOLITION AND NEW WORK DRAWINGS FOR ADDITIONAL REQUIREMENTS.4 PROVIDE PROTECTION AGAINST MOISTURE, IMPACT AND OTHER TYPES OF DAMAGE AT ALL
OPENINGS CREATED BY SELECTIVE DEMOLITION AND NEW CONSTRUCTION WORK. REPAIR ANDREPLACE DEMAGED AREAS AT NO ADDITIONAL COST TO THE OWNER.
5 ALL PENETRATIONS OF EXISTING FLOORS AND FIRE RATED WALL OR SMOKE PARTITIONS SHALL BEPATCHED & REPAIRED AS REQUIRED TO MAINTAIN THE EXISTING FIRE RATING OR SMOKEINFILTRATION INTEGRITY OF THE WALL. ALL SLEEVES, WIREWAYS, CABLE TRAYS, PIPES, DUCTWORK,ETC. SHALL BE FIRE SEALED TIGHT TO THE WALL OR FLOOR PENETRATIONS TO MAINTAIN THEREQUIRED CODE COMPLIANT FIRE RATING.
6 EXISTING FLOOR PENETRATIONS, WHERE PIPING, DUCTWORK, CONDUIT OR OTHER ITEMS HAVEBEEN REMOVED DURING DEMOLITION ARE TO BE FILLED WITH CONCRETE TO MATCH THE EXISTINGSURROUNDING FLOOR AND REQUIRED FIRE RATINGS.
KEY PLAN - THIRD FLOOR
NOTE: SEE 2/G200 CONSTRUCTIONCOORDINATION PLAN FOR SECONDFLOOR CEILING DEMOLITION PLAN
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
NEW WALL
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
NEW DOOR AND FRAME
3 4 5 6
A
B
ANIMALHOUSING 2
335 B
ANIMALHOUSING 1
335 A
PROCEDURELAB335
PSYCHMARINE
HOUSING333
335
335-A
335-B
CORRIDOR383
18' -
3 3/8"
A200 2
4
1
3
A200 9
A200
6
5
7
8
10
PSYCHMARINE
DIAGONISTICLAB327
0203
XEQ-206
XEQ-207
2202
1211
1212
1212
1203
XEQ-205XEQ-209
2205
XEQ-209
EQ-201
EQ-201
XEQ-205
EQ-200
02030203
XEQ-201
XEQ-202XEQ-105
XEQ-106
12' - 0" 8" 8' - 6" 11 1/8" 6' - 2 7/8"
333
A200 11
12
13W1A
W2A
W2A
W2A
W2A
W2B
W2A W2A
0901
0902
1206
1207
14' - 6"
9' - 2
1/8"
8' - 9
1/4"
XEQ-006
XEQ-001
XEQ-002
XEQ-005
XEQ-004
XEQ-003 XEQ-107
XEQ-
108
EQ-1
002204
0903
2206
5' - 0
7/8"
5' - 0
"8'
- 2 1/
2"
18' -
3 3/8"
W1A
XEQ-204
0902
2201
0203
2207
2203
EQ-202
XEQ-
108
327-B
0901
0902
12031212
0914
0914
327-A
0914
0914
2209
2210
221013
12
11 7
8
10
9
5
6
1
3
4
2
0914
W2A
2202
04010401 1203
3"
2' - 6
"
2' - 4
1/4"
A4008
0241 A4005
Sim
3 4 5 6
A
B
PROCEDURELAB335
ANIMALHOUSING 1
335 A
ANIMALHOUSING 2
335 B
PSYCHMARINE
HOUSING333
PSYCHMARINE
DIAGONISTICLAB327
8' - 6" 8' - 6" 8' - 0"
8' - 0"
8' - 0"
0904
0904
0905
09050904
CORRIDOR383
H
HH
H
H
OC
OC
0915
HOLD
2' - 0"EQ 8' - 0" EQ
EQ 12' - 0" EQ
3 4 5
A
B
02330233
2302
VIF
3' - 3"
VIF
6' - 3
"
VIF
5' - 3
"
0230
1
A400
Sim
2
A400
Sim
0705
0242
02120212
3
A400
Sim
2201
2x4 LIGHT FIXTURE
MECH. SUPPLY DIFFUSER
MECH. RETURN DIFFUSER
RECESSED CAN LIGHT FIXTURE
GYPSUM BOARD CEILING
2X2 ACOUSTICAL CEILING TILE
EXISTING CEILING TILE TO REMAIN
H HEAT DETECTOR
OC OCCUPANCY SENSOR
PROJECT AREA
FLOOR PLAN LEGEND
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
15:5
4 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
ARCHITECTURAL FLOOR PLANS
A100
VIVARIUM & MARINEORGANISMS RENOVATION
AJL
4/24/2013
MP
1302-13-01
6 23 1/4" = 1'-0"THIRD FLOOR PLAN
1
SHEET KEYNOTES0203 EXISTING FLOOR DRAIN TO REMAIN0212 EXISTING GREEN HOUSE ENCLOSURE. TO REMAIN.0230 EXISTING GREEN HOUSE0233 EXISTING VENTS TO REMAIN0241 EXISTING HM DOOR AND FRAME TO REMAIN0242 EXISTING ROOF TO REMAIN, TYPICAL0401 PATCH AND SEAL WALL AT AREA OF MECH DUCT REMOVAL. MAINTAIN THE ASSUMED
1-HR FIRE RATING OF WALL. VIF.0705 NEW INSULATED ROOF HATCH COVER.0901 NEW LAB CASEWORK, UPPER AND BASE CABINET0902 NEW LAB CASEWORK, UPPER AND BASE CABINET. NEW SOLID SURFACE COUNTERTOP0903 SOLID SURFACE SPLASH GUARD.0904 NEW ACOUSTIC CEILING TILE0905 NEW DRYWALL CEILING0914 SCHEDULED FLOOR FINISH0915 REINSTALL EXISTING CEILING SYSTEM AND CEILING MOUNTED DEVICES. REFER TO
SHEET D100.1203 2' H X 1'-6" W TACK BOARD1206 UPPER STORAGE CABINET WITH ADJUSTABLE SHELVES1207 EXISTING GARBAGE CONTAINER1211 WALL-HUNG GLASSWARE PEGBOARDS, 18"X24" MODEL NO. 52L80500.1212 FULL-HEIGHT LAB CASEWORK CABINETS2201 NEW PLUMBING VENT THROUGH ROOF, SEE PLUMBING.2202 EYE WASH, COUNTER TOP MOUNTED. SEE PLUMBING.2203 SINK WITH IR SENSOR AND MANUAL SPRAYER, SEE PLUMBING.2204 RE-INSTALL EXISTING STAINLESS STEEL COUNTERTOP AND INTEGRAL SINK. INSTALL
NEW FAUCETS AND FOOT PEDAL CONTROL. SEE PLUMBING.2205 NEW FLOOR DRAIN, SEE PLUMBING DRAWING.2206 RECONNECT AND RE-INSTALL EXISTING WALL-MOUNTED EYEWASH, SEE PLUMBING.2207 SINK WITH FOOT PEDAL CONTROL AND MANUAL SPRAYER, SEE PLUMBING DRAWING.2209 WALL MOUNTED WASH-DOWN HOSE, SEE PLUMBING.2210 PATCH AND FILL EXISTING PLUMBING PIPES. CUT CONCRETE. VERIFY NOT IN
OPERATION AND PLUG PIPING.2302 NEW ROOF EXHAUST OVER PRE MANUFACTURED CURB, SEE MECHANICAL SPEC AND
DRAWING.
0 2' 4' 8'
SHEET NOTES - PLAN
10 ALL PENETRATIONS OF FLOORS AND FIRE RATED WALL OR SMOKE PARTITIONS SHALL BEPATCHED & REPAIRED AS REQUIRED TO MAINTAIN THE EXISTING FIRE RATING OR SMOKEINFILTRATION INTEGRITY OF THE FLOOR AND WALL ALL SLEEVES, WIREWAYS, CABLE TRAYS,PIPES, DUCTWORK, ARE TO BE FIRE SEALED TIGHT TO THE WALL OR FLOOR PENETRATIONS TOMAINTAIN THE REQUIRED CODE COMPLIANT FIRE RATING.
11 DO NOT APPLY NEW FINISHES TO EXISTING WALL AND CEILING MOUNTED DEVICES, FIXTURES,COVER PLATES, SIGNAGE, HARDWARE, ITEMS, ETC, LOCATED ON EXISTING SURFACESSCHEDULED TO BE REFINISHED. EXISTING ITEMS THAT ARE NOT REMOVABLE SHALL BECAREFULLY TAPED, OR OTHERWISE COVERED DURING REFINISHING. WHERE NEW FINISHES AREAPPLIED EXISTING FINISHES NO LONGER VISIBLE SURROUNDING EXISTING ITEMS.
12 PROVIDE HEAVY GAUGE METAL STRAPPING OR FIRE RATED BLOCKING WITHIN THE WALL CAVITYFOR ALL WALL MOUNTED EQUIPMENT, GRAB BARS, AND CABINETS.
13 INSTALL SEALANT AND BACKER ROD AT ALL HORIZONTAL EDGES WHERE NEW AND/OR EXISTINGWALLS MEET THE STRUCTURE ABOVE. ALSO ADD SEALANT AND BACKER ROD TO VERTICALEDGES WHERE NEW AND/OR EXISTING WALLS MEET AND AT EXISTING DOOR LINTELS.
14 PATCH AND REPAIR EXISTING WALLS. THE TOTAL AMOUNT OF PATCHING IS ASSUMED TO BEAPPROXIMATELY 21 LINEAL FEET.
SHEET NOTES - PLAN
6 WHERE EXISTING MASONRY PARTITIONS ARE REMOVED FOR NEW OPENINGS & WHEREEXISTING OPENINGS ARE ENLARGED, PATCH AND FINISH NEW OPENINGS AS REQUIRED BYTOOTHING NEW OPENING TO MATCH EXISTING PARTITIONS. MAINTAIN EXISTING ACOUSTICPERFORMANCE AND REQUIRED FIRE AND SMOKE RATINGS.
7 CLEAN AND PREPARE FOR NEW FINISHES EXISTING SURFACES INDICATED TO REMAIN.COORDINATE WITH THE VA REMOVAL AND DISPOSAL OF UNWANTED SIGNAGE, FIXTURES,HARDWARE, ETC. ON EXISTING SURFACES TO MATCH EXISTING SUBSTRATES AND PROVIDE ANADDITIONAL PRIME PAINTED COATING ON ALL REPAIRS PRIOR TO REFINISHING AS SCHEDULED.COORDINATE WITH THE REQUIREMENTS OF THE FINISH SCHEDULE.
8 LEVEL EXISTING FLOOR SURFACES SCHEDULED WITH NEW FLOOR FINISHES AS REQUIRED TOPROVIDE LEVEL AND FLAT FLOOR SURFACES.
9 FURNISH AND INSTALL REINFORCEMENT REQUIRED FOR WALL, FLOOR, OR CEILING MOUNTEDITEMS, INCLUDING OWNER & VENDOR MOUNTED ITEMS.
SHEET NOTES - PLAN
1 CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONSPRIOR TO COMMENCING THE WORK. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS,ELEVATION HEIGHTS, CONSTRUCTION AND BUILDING SYSTEMS IN THE FIELD AND PRIOR TOPROCEEDING WITH THE WORK.
2 CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES BETWEEN THECONTRACT DOCUMENTS AND EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK.
3 ROOM LAYOUTS AND CONFIGURATIONS AND FOR AREAS OUTSIDE OF THE CURRENT WORK ARESHOWN FOR REFERENCE ONLY. EXISTING CONSTRUCTION IS BASED UPON LIMITED SURVEYS BYTHE ARCHITECT AND INFORMATION PROVIDED BY THE OWNER. FIELD VERIFICATION PRIOR TOCOMMENCEMENT OF CONSTRUCTION IS REQUIRED.
4 IN AREAS OF REMOVAL AND WHERE NEW WORK AND/OR FINISHES ARE NOT SCHEDULED,CONTRACTOR SHALL REPAIR, PATCH AND CLEAN WALLS, FLOORS, WALL BASES, AND CEILING ASREQUIRED TO MATCH EXISTING FINISHES TO BE FLUSH, SMOOTH, AND MATCH ADJACENTMATERIALS IN ALL RESPECTS. RELOCATE LIGHT FIXTURES AND OTHER CEILING AND WALLMOUNTED DEVICES WHERE NEW PARTITIONS ARE SHOWN ADJACENT TO AREAS NOTSCHEDULED FOR NEW FINISHES.
5 PREPARE ALL EXISTING SURFACES TO REMAIN PROVIDING CLEAN SMOOTH SURFACES TORECEIVE SCHEDULED FINISHES. LEVEL FLOOR SLAB SURFACES AS REQUIRED TO PROVIDE AFLAT, LEVEL SURFACE FOR FLOORING INSTALLATIONS. REFERENCE THE FINISH SCHEDULESHEET AND THE FINISH PLANS SHEETS FOR RELATED REQUIREMENTS.
1/4" = 1'-0"THIRD FLOOR REFLECTED CEILING PLAN
20 2' 4' 8'
1/4" = 1'-0"ROOF PLAN
3
REFLECTED CEILING PLAN LEGEND
KEY PLAN - THIRD FLOOR
0 2' 4' 8'
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
XEQ-201
XEQ-202
1205
09090909 0909
090709070907
335-B 335-A 8' - 0
"
11 3/
8"2'
- 1 1/
4"4'
- 11 1
/2"
8' - 0
"
WC-3
EQ-200
XEQ-205
1207
0907
1206
0909
1' - 1 3/4"
2209
2' - 6" 2' - 6" 5' - 0" 1" 4' - 0" 4' - 0"
WC-3 WC-3
BC-2
FC-2 FC-2
0909
0910
0910
0907
1206
1212 1212
0911
0913
11 3/
8"2'
- 1 1/
4"4'
- 11 1
/2"
8' - 0
"
0403
2202
2211
1207
XEQ206 XEQ207
1' - 2
"
PB-1
BC-2
FC-2
2' - 0"
3' - 0
"4'
- 0 5/
8"11
3/8"
XEQ-205
335
0908
0913
1212
8' - 0
"
0910
0910
S T
A
1203
0907
4' - 8
"
XEQ-209
0909
0907
8' - 0
"
1' - 5
3/8"
2' - 1
1/4"
1' - 1
1 1/2"
3' - 0
"
FC-1 WC-4 WC-5 WC-3
BC-5
BC-1 EC-1
4" 3' - 6" 3' - 0" 4' - 0" 2' - 6" 4' - 11 3/8"
4" 3' - 6" 3' - 0" 4' - 0" 2' - 6" 4' - 11 3/8"
8' - 6
"
XEQ-106 XEQ-107
0911
0910
0907
2206
1212
327-B
2207
2602
KS-1
2606
0404
S
2212
2211TC
1' - 2
"
4"
0911
3' - 0
"1'
- 11 1
/2"2'
- 1 1/
4"1'
- 5 3/
8"
8' - 6
"
2' - 0"6' - 6"
WC-5
BC-5
FC-1
1' - 1 3/4"
09110910
0907
333
0908
2602
2606
T
A
1203
4' - 8
"
1' - 5
3/8"
2' - 1
1/4"
1' - 1
1 1/2"
3' - 0
"
8' - 6
"
2' - 0"
WC-5
BC-5
0911
0909
0907
XEQ-107
2602
2606XEQ-107
XEQ-108 XEQ-1080910
EQ-100
0907
3' - 0
1/8"
2' - 0
"3'
- 5 7/
8"
2602
2602
8' - 6
"
2213
2' - 0" 2' - 6" 1" 3' - 0" 2' - 0" 3' - 0"
WC-2 WC-3 WC-4 WC-1 WC-4
BC-3BC-6BC-1BC-4
0910
0911 0906
0907
8' - 6
"
1' - 5
3/8"
2' - 1
1/4"
1' - 1
1 1/2"
3' - 0
"
2602327-B
KS-1
26060402
1210
0404
2212
2202
LG-1
1' - 5
3/8"
2' - 1
1/4"
1' - 1
1 1/2"
3' - 0
"
2' - 0"
WC-2
BC-4
8' - 6
"
XEQ-005
XEQ-003
0906
0909
1210
2602
2606
2602
A40010
0907
0241
XEQ-006 XEQ-001
XEQ-002
XEQ-004
XEQ-005
XEQ-003
8' - 6
"
2602
0910
0907
XEQ-209
0909
0907
8' - 0
"
QUAD OUTLET
DUPLEX OUTLET
DATA OUTLET
FIRE ALARM
SWITCH
THERMOSTATT
S
A
TIME SWITCHTC
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
16:0
1 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
1/2" = 1'-0"
INTERIOR ELEVATIONS
A200
VIVARIUM & MARINEORGANISMS RENOVATION
PG
4/24/2013
MP
1302-13-01
7 23 1/2" = 1'-0"
ROOM 335 EAST10 6" 1'
SHEET KEYNOTES0241 EXISTING HM DOOR AND FRAME TO REMAIN0402 PATCH HOLES IN WALL0403 PATCH AND REPAIR STRUCTURAL GLAZED FACING TILE BEHIND0404 PATCH WALL ABOVE DOOR HEAD AND PROVIDE METAL LINTEL FOR NEW DOOR
OPENING.0906 EXISTING STAINLESS STEEL COUNTERTOP WITH INTEGRAL SINK0907 SCHEDULED BASE0908 EXISTING COLUMN, PAINT PER SCHEDULE.0909 SCHEDULED WALL FINISH0910 PATCH AND CLEAN EXISTING STRUCTURAL GLAZED FACING TILE WALL0911 SOLID SURFACE COUNTERTOP AND BACKSPLASH, 14" BACKSPLASH AT SINKS.0913 NEW LAB CASEWORK, BASE CABINET. NEW SOLID SURFACE COUNTERTOP1203 2' H X 1'-6" W TACK BOARD1205 MOBILE COMPUTER STATION1206 UPPER STORAGE CABINET WITH ADJUSTABLE SHELVES1207 EXISTING GARBAGE CONTAINER1210 SOLID SURFACE DIVIDER, SEE SPEC 1235531212 FULL-HEIGHT LAB CASEWORK CABINETS2202 EYE WASH, COUNTER TOP MOUNTED. SEE PLUMBING.2206 RECONNECT AND RE-INSTALL EXISTING WALL-MOUNTED EYEWASH, SEE PLUMBING.2207 SINK WITH FOOT PEDAL CONTROL AND MANUAL SPRAYER, SEE PLUMBING DRAWING.2209 WALL MOUNTED WASH-DOWN HOSE, SEE PLUMBING.2211 DECK MOUNTED MANUAL SPRAYER, SEE PLUMBING2212 FOOT PEDAL CONTROL FOR FAUCETS, SEE PLUMBING.2213 WATER FEED FOR FISH TANK, SEE PLUMBING.2602 ELECTRIC RACEWAY, SEE ELECTRICAL2606 UNDERCABINET LIGHTING UNDER UPPER CABINETS. SEE ELECTRICAL DRAWINGS.
0 6" 1'
0 6" 1' 1/2" = 1'-0"
ROOM 335 SOUTH4
1/2" = 1'-0"
ROOM 335 WEST2
1/2" = 1'-0"
ROOM 335 NORTH30 6" 1'
1/2" = 1'-0"
ROOM 335 B NORTH5
0 6" 1' 1/2" = 1'-0"
ROOM 333 EAST70 6" 1'
1/2" = 1'-0"
ROOM 333 NORTH8 1/2" = 1'-0"
ROOM 333 SOUTH10 1/2" = 1'-0"
ROOM 333 WEST90 6" 1'
0 6" 1'0 6" 1' 1/2" = 1'-0"
ROOM 327 WEST11 1/2" = 1'-0"
ROOM 327 SOUTH12 1/2" = 1'-0"
ROOM 327 EAST130 6" 1'
0 6" 1'0 6" 1'
0 6" 1'
NOTE:SEE A300 FOR LAB CASEWORK SCHEDULE
1/2" = 1'-0"
ROOM 335 B SOUTH6
ELEVATION SYMBOLS
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
TYPICAL HEADJAMB AT HEAD
CONTINUOUS RUNNERTRACK ATTACHED TONESTED STUD
CONTINUOUS RUNNERTRACK ATTACHED TONESTED STUD
CONTINUOUS METALSTUD NESTED INTOBOTTOM RUNNERTRACK
REFER TO WEB CONNECTIONNOTE UNDER JAMB/HEAD TYPE 1,THIS DETAIL
EXTEND RUNNER TRACK FLANGES 1 5/8"MIN EACH SIDE BEYOND FACE OF JAMB.PROVIDE 3/4" LOW PROFILE #10 PANHEAD SHEET METAL SCREWS EACH SIDE
OPENING HEAD FRAMING
DOUBLE METAL STUD JAMB
FRAME TYPE: 1
2" SEE SCHEDULE 2"
SEE
SCH
EDU
LE2"
DOOR TYPE: A
SEE
SCH
EDU
LE
SEE SCHEDULE
DOOR TYPE: AA
SEE
SCH
EDU
LE
3' - 0" 1' - 0"
FRAME TYPE: 2KNOCKDOWN TYPE
2" SEE SCHEDULE 2"
SEE
SCH
EDU
LE4"
20 GA DOUBLE METAL STUDASSEMBLY. REFER TO TYPICAL
FRAME ELEVATIONS.STAGGER SCREW GYP BD TO
EACH STUD @ 16" O.C.VERTICAL, TYPICAL
SEALANT, BOTH SIDES
GROUT FRAME SOLID, TYP.
FRAME ANCHOR - REFER TOSPECIFICATIONS FOR NUMBER ANDSPACING
HOLLOW METAL FRAME
1/2" T
YP.
4" TYP. 2"
VARI
ES, V
IF (4
7/8"
)
ADJ. WALL
SCHEDULED DOOR
4" 2"
EXISTING STRUCTURALGLAZED FACING TILE
GROUT FRAMESOLID, TYP
HM FRAME
SCHEDULEDDOOR
FRAME ANCHOR
SEALANT, BOTH SIDES
VARI
ES, V
IF (7
5/8"
ASS
UMED
)ADJ. WALL
COUNTERSUNK FLATHEADBOLT WITH CAP
REFER TO TYP. FRAMINGELEVATIONS FOR REQUIREDFRAMING OVER OPENING.
SEALANT - TYPICAL BOTH SIDES
HM FRAME
GROUT FRAME SOLID, TYP.
TURN-UP STUD RUNNER & 1/4"EXPANSION ANCHOR TO EXIST.MASONRY @ MASONRY JAMBS,V.I.F.
1/2" 1/2"
2"
SCHEDULED DOOR
VARIES, VIF (4 7/8")
EXISTING GLAZED FACINGTILE WALL, SAW CUTOPENING TYP. DO NOTOVER CUT.
GROUT HEAD
HM FRAME
SCHEDULED DOOR
4"
SEALANT, BOTHSIDES TYP.
L 3-1/2x3-1/2x5/16 METALANGLE LINTEL, EXTEND4" OR 6" MIN. BOTH SIDEOF THE DOOR.
VARIES, VIF (7 5/8" ASSUMED)
SAW CUT THE BRICK TOACCOMODATE METALANGLE FLANGES.
WELD 5/16" THICK METALPLATE TO THE ANGLELINTEL
DOOR SCHEDULE
ROOM
NUM
BER
ROOM NAME DOOR
NUM
BER DOOR FRAME DETAILS
HARD
WAR
E SE
T
FIRE RATING COMMENTSWIDTH HEIGHTTHICKNES
S TYPEMATERI
AL FINISH TYPE MATERIAL FINISH HEAD JAMB
327 PSYCH MARINE DIAGONISTIC LAB 327-A 4' - 0" 7' - 0" 1 3/4" AA WD MATCH EXISTING 1 EXISITNG EXISTING EXISTING EXISTING 1 Class C, 45min327 PSYCH MARINE DIAGONISTIC LAB 327-B 3' - 0" 7' - 10" 1 3/4" A WD MATCH EXISTNG 2 HM PT-3 5 4 2333 PSYCH MARINE HOUSING 333 3' - 6" 7' - 10" 1 3/4" A WD MATCH EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 1.1 Class C, 45min335 PROCEDURE LAB 335 4' - 0" 7' - 10" 1 3/4" A WD MATCH EXISTING EXISTING EXISITNG EXISTING EXISTING EXISTING 1.2 Class C, 45min335 A ANIMAL HOUSING 1 335-A 3' - 0" 7' - 10" 1 3/4" A WD MATCH EXISTING 1 HM PT-3 3 2 2.1335 B ANIMAL HOUSING 2 335-B 3' - 0" 7' - 10" 1 3/4" A WD MATCH EXISTING 1 HM PT-3 3 2 2.1
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
16:0
4 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
CASEWORK, DOOR, EQUIPMENT &FINISH SCHEDULES
A300
VIVARIUM & MARINEORGANISMS RENOVATION
PG
4/24/2013
MP
1302-13-01
8 23
ROOM FINISH LEGENDMATERIAL
TYPE / CODE MATERIAL DESCRIPTIONMATERIAL
MANUFACTURER MANUFACTURER MODEL, SIZE & COLOR MATERIAL REMARKS
ACT-1 ACOUSTICAL CEILING TILE SEE SPEC 095113 2x2, WHITE CLEAN ROOM TILE,SCRUBABLE
CB-1 INTEGRAL COVE BASE SEE SPEC 096700 STONEHENGE(ROCKTREAD BASIS OF DESIGN)EPX-1 EPOXY FLOOR FINISH SEE SPEC 096700 STONEHENGE(ROCKTREAD BASIS OF DESIGN)PT-1 EPOXY PAINT--MAIN FIELD WALL COLOR SEE SPEC 099123 IBIS WHITE (SHERWIN WILLIAMS BASIS OF DESIGN) LOW VOCPT-2 EPOXY PAOINT-- ACCENT WALL COLOR SEE SPEC 099123 ANALYTICAL GRAY (SHERWIN WILLIAMS BASIS OF DESIGN) LOW VOCPT-3 EPOXY PAINT - DOOR FRAME COLOR SEE SPEC 099123 SIMPLE WHITE (SHERWIN WILLIAM BASSIS OF DESGIN) LOW VOCPT-4 METAL CASEWORK COLOR SEE SPEC 123553 DARK KHAKI (THERMO FISHER BASIS OF DESIGN)SS-1 SOLID SURFACE COUNTER SEE SPEC 123553 SMOKE ICE (FORMICA BASIS OF DESIG)
ROOM FINISH SCHEDULE
ROOM NUMBER ROOM NAME CEILING FINISHWALL FINISH FLOOR
FINISHBASE
FINISH COMMENTSNORTH SOUTH EAST WEST
327 PSYCH MARINE DIAGONISTICLAB
ACT-1 EXISTING PT-2 PT-1 EXISTING EPX-1 CB-1 EXISTING COLUMNS - PT1
333 PSYCH MARINE HOUSING ACT-1 EXISTING PT-2 EXISTING EXISTING EPX-1 CB-1 EXISTING COLUMNS - PT1335 PROCEDURE LAB ACT-1 EXISTING PT-2 PT-1 EXISTING EPX-1 CB-1 EXISTING COLUMNS - PT1335 A ANIMAL HOUSING 1 GWB, PT-1 PT-2 PT-2 PT-2 PT-2 EPX-1 CB-1335 B ANIMAL HOUSING 2 GWB, PT-1 PT-2 PT-2 PT-2 PT-2 EPX-1 CB-1
1 1/2" = 1'-0"HEAD TRACK FRAMING
1
1/2" = 1'-0"DOOR & FRAME TYPES
8
0 6" 1'
CASEWORK SCHEDULETYPE MODEL DESCRIPTION WIDTH DEPTH HEIGHT COUNT FINISH COMMENTS
BC-1 115J6320 Flush Overlay Steel Base Cabinet 3' - 0" 1' - 9 1/8" 2' - 11 1/4" 2 PT-4 FOOT PADELCONTROL
BC-2 029J832L Flush Overlay Steel Base Cabinet 5' - 0" 1' - 9 1/8" 2' - 11 1/4" 1 PT-4 LOCKBC-3 106J632L Flush Overlay Steel Base Cabinet 3' - 0" 1' - 9 1/8" 2' - 11 1/4" 1 PT-4 LOCKBC-4 303J432L Flush Overlay Steel Base Cabinet 2' - 0" 1' - 9 1/8" 2' - 11 1/4" 1 PT-4 LOCKBC-5 306J8320 Flush Overlay Steel Base Drawers 4' - 0" 1' - 9 1/8" 2' - 11 1/4" 1 PT-4BC-6 341J432L Flush Overlay Steel Base Cabinet 2' - 0" 1' - 9 1/8" 2' - 11 1/4" 1 PT-4 LOCKEC-1 525J3680 Flush Overlay Steel End Support Panel 7/8" 2' - 4 7/8" 2' - 11 1/4" 1 PT-4FC-1 806J792L Flush Overlay Steel Tall Cabinet 3' - 6" 1' - 10" 7' - 0 5/8" 1 PT-4 LOCKFC-2 806J892L Flush Overlay Steel Tall Cabinet 4' - 0" 1' - 10" 7' - 0 5/8" 2 PT-4 LOCKKS-1 FO Steel
KneespaceFlush Overlay Steel Kneespace Panel and Rails 1' - 9 1/8" 2' - 11 1/4" 2 PT-4
LG-1 522J3610 Leg Assembly 1' - 9 5/8" 2' - 11 1/4" 1 PT-4PB-1 52L80500 Glassware Pegboard 1' - 6" 1" 2' - 0" 1 PT-4SC-1 618J0340 Flush Overlay Steel Fillers and Scribes 1" 2" 2' - 11 1/4" 6 PT-4WC-1 702J423L Flush Overlay Steel Wall Cabinet 2' - 0" 1' - 1" 2' - 1 1/4" 1 PT-4 LOCKWC-2 703J423L Flush Overlay Steel Wall Cabinet 2' - 0" 1' - 1" 2' - 1 1/4" 1 PT-4 LOCKWC-3 706J523L Flush Overlay Steel Wall Cabinet 2' - 6" 1' - 1" 2' - 1 1/4" 4 PT-4WC-4 706J623L Flush Overlay Steel Wall Cabinet 3' - 0" 1' - 1" 2' - 1 1/4" 3 PT-4 LOCKWC-5 706J823L Flush Overlay Steel Wall Cabinet 4' - 0" 1' - 1" 2' - 1 1/4" 1 PT-4 LOCK
0 3" 6"
EQUIPMENT SCHEDULE -- SEE ALSO SPECIFICATION SECTION 11 00 00EQUIPMENT
NUMBER DESCRIPTION MANUFACTURER ROOM POWER REQ PROVIDED BY COMMENTS
EQ-100 Fish tank system (Z-Hib Mini) Aquatic Habitat, Benchtop 333 120V -10.5A OFOI (Owner filter). Future installationEQ-200 Bedding station Techiplast, DS36 335 115V - 8.6 A CFCI Exhaust and air filter in the equipmentEQ-201 Animal cage racks TBD 335 NA OFCI Quantity 2EQ-202 Mobile Computer Station TBD 335 NA OFOI
XEQ-001 Tool box Existing 327 NA OFCI With operable lidXEQ-002 Cyro Existing 327 - OFCI Open RHSXEQ-003 Faraday box Existing 327 NA OFCIXEQ-004 Faraday box Existing 327 NA OFCIXEQ-005 Table Existing 327 NA OFCIXEQ-006 Full-height cabinet Existing 327 NA OFOIXEQ-100 Digital Scale 1 Existing 333 120V OFCI On countertop, new locationXEQ-101 Digital scale 2 Existing 333 120V OFCI On countertop, new locationXEQ-102 Sonic cleaner Existing 333 120V OFCI On countertop, new locationXEQ-103 PH meter Existing 333 120V OFCI On countertop, new locationXEQ-104 Side warmer Existing 333 120V OFCI On countertop, new locationXEQ-105 Flammable storage Existing 333 NA OFCI Yellow box, below countertopXEQ-106 Acid storage Existing 333 NA OFCI Blue box, below countertopXEQ-107 Refrigerator Existing 333 120V OFCIXEQ-108 Racks Existing 333 NA OFCI Quantity 2XEQ-109 Tank Existing 333 NA OFCI Quantity 10, filter and heater in each tankXEQ-200 Digital scale Existing 333 120V OFCIXEQ-201 Circadian box 1 Existing 333 120V OFCI Cabinet has built-in exhaust but needs to have some
clearance to accommodate the internal exhaustXEQ-202 Circadian box 2 Existing 333 120V OFCI Cabinet has built-in exhaust but needs to have some
clearance to accommodate the internal exhaustXEQ-204 Desktop computer Existing 333 120V OFCI Quantity 2XEQ-205 Mobile metal table Existing 333 NA OFCI Quantity 2XEQ-206 Bedding bin Existing 333 NA OFCIXEQ-207 Food hopper Existing 333 NA OFCIXEQ-208 Morris water maze Existing 333 NA OFCI Stored in closet and used when neededXEQ-209 Cage rack Existing 333 NA OFCI Quantity 2XEQ-210 Small lab equipment Existing 333 - OFCI Blue equiment next to scale
EQUIPMENT LEGENDCF CONTRACTOR FURNISHEDCI CONTRACTOR INSTALLEDOF OWNER FURNISHEDOI OWNER INSTALLED
0 3" 6"
0 6" 1'
3" = 1'-0"DOOR JAMB DETAIL - STUD WALL
2
3" = 1'-0"DOOR JAMB DETAIL - EXISTING WALL
4
3" = 1'-0"DOOR HEAD DETAIL - STUD WALL
3
3" = 1'-0"DOOR HEAD DETAIL - EXISTING WALL
5
0 3" 6"
0 3" 6"
NOTE: BASIS OF DESIGN: THERMO FISHER SCIENTIFIC, SEE SPEC SECTIO 123553
NOTE: SEE SPEC SECTION 08 71 00 FOR HARDWARE SET
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
1 1/2"
1/4"4" 1"
EASE EDGES, UNO
FACE OFDOOR/DRAWER
SOLID SURFACENOTE: TYPICAL AT SOLIDSURFACE COUNTERS
3/4" CONTINUOUSFIRERATED
PLYWOOD BACKING
14" A
T SI
NKS
SEE
ELEV
ATIO
N4"
TYP
.
1/2"
SIDESPLASH BEYOND IFAPPLICABLE. SEE ELEV.
BACKSPLASH TO MATCHCOUNTERTOP
CONSTRUCTION
SOLID SURFACECOUNTERTOP
SEE SPEC 123553
3/4" CONT FIRE RATEDPLYWOOD BACKING
CONTINUOUS SUPPORTBRACKET
OR BASE CAB.
POST FORM COVE ATSINK LOCATIONS
EASE EDGE, TYP.
SEAL CONT, TYP.
1'-0"
MIN
.
EXISTING CONC.DECK TO REMAIN.
PLUMBING VENT PIPE SEEPLUMBING DRAWINGS
CUT NEW OPENING FOR ROOF VENT,MINIMIZE SIZE OF NEW OPENING INEXISTING DECK. PACK VOIDS WITHMINERAL FIBER INSULATION.
EXISTING ROOFINSULATION, PATCH TO
MATCH AS REQUIRED.
EXISTING BUILT-UPROOFING, IF.
TOP OF FLANGE CAPPED ORROLLED INTO VENT PIPE APPROX 1"
LEAD PIPE FLASHING.
BITUMINOUS SEALANT
BASE FLASHING PLY8" MIN. ON FIELD
BITUMINOUSSEALANT, TYP
PATCH INSULATION TOMATCH TIGHT TO PIPE,TYP.
EXISTING VAPOR BARRIER(#40 BASE SHEET) TOREMAIN, PATCH ANDRESEAL THE OPENING.
MODIFIED MEMBRANEFLASHING PLY 12" MIN. ONFIELD
1" RADIUS COVE
EXISTING STRUCTURAL GLAZEDFACING TILE OR NEW GWBSUBSTRATE
1/8" METAL TERMINATION BAR
SCHEDULED EPOXYFLOORING SYSTEM OVEREXISTING FLOORING
EXISTINGCONCRETE FLOORSLAB TO REMAIN
SEALANT CONTINUOUS
1/8" SCHEDULED EPOXY BASE
EXISTING VINYL FLOORINGAT THRESHOLD/ CORRIDORTO REMAIN
SAWCUT EDGE ATTHRESHOLD
MATC
H EX
ISTI
NG
5" V
IF
EXISTING EPOXY FLOORINGAND INTEGRAL BASE. PREPAREFOR NEW SCHEDULED FLUIDAPPLIED EPOXY FLOORING.
CORRIDOR DOOR
NEW INSULATED FIXEDCUSTOM FABRICATED
HATCH COVER WITHPERIMETER SEALS, VIF
1 1/2" CLOSE-CELLPOLYURETHANE SPRAY
FOAM INSULATION
EXISTING CONCRETEDECK TO REMAIN
EXISTING INSULATIONFILL TO REMAIN
EXISTING BUILT UP ROOFAND FLASHING TO REMAIN
MIN.
7"
EXISTING HATCHCURB, TO REMAIN
1 5/8" GLAV. METALSTUDS @ 16" OC
5/8" FIBERREINFORCED WATERRESISTANT GYPSUM
BOARD
EXISTING COUNTERFLASHING TO REMAIN
EXISTING METAL OPENINGFRAME, SAND AND PAINTWITH GALVANIZED PAINT
ANCHOR DOWN THECOVER TO THE CURB
CONT. COMPRESSED FOAMTAPE WEATHER SEAL
CONT SEALANT ANDBACKER ROD
NEW ROOF TOP EXHAUSTFAN, SEE MECHANICAL
EXISTING CONCRETEDECK TO REMAIN
EXISTING INSULATIONFILL TO REMAIN
EXISTING BUILT UP ROOFAND FLASHING TO REMAIN
PREMANUFACTUREDINSULATED CURB, SEE
MECHANICAL
BASE FLASHING PLY6" MIN. ON FIELD, UPAND OVER THE CURB
8" M
IN.
MODIFIED MEMBRANEFLASHING PLY 9" MIN. ONFIELD, UP AND OVER THECURB
HOOD FLASHING CAP,SECURED W/ FASTENERS ANDNEOPRENE WASHERS
SEALANT, TYP.
SEALANT T/O, TYP.
SEALANT, TYP.
9A400 NEW SOLID SURFACE
COUNTERTOP WITHBLACK SPLASH
EXISTING STAINLESSSTEEL COUNTERTOPWITH INTEGRAL SINK,
REINSTALL
1/2" SOLID SURFACE
EXISTING WALLTO REMAIN
3/4" FIRERATEDPLYWOOD
1 3/4"
2" 1' - 9" 2"
2' - 1"
STAINLESS STEELANGLE BRACKET
EXISTING STAINLESS STEELCOUNTERTOP WITH INTEGRAL
SINK, REINSTALLED
LAB CASEWORKLEG SUPPORT
1" GAP, VIF
1/2" SOLIDSURFACE TOP
3/4" FIRERATEDPLYWOOD BACKING
BACKSPLASH 1' - 6
"
NEW METAL LAB CASEWORK
1 3/4"
1/2" SOLID SURFACE
3/4" FIRERATEDPLYWOOD BACKING
MIN2"
3/4" SOLID SURFACE
STAINLESS STEELANGLE BRACKET
SHIM AS NECESSARY
2' - 1"
80.00°
87.00°
1' - 6
"
4"
SOLID SURFACEDIVIDER
COUNTER TOP
STAINLESS STEELANGLE BRACKET
1' - 6
"
EXISTING STRUCTURAL GLAZEDFACING TILE WALL TO REMAIN.
SEALANT AND BACKERROD, CONT. TYP.
5/8" FIBER REINFORCEDWATER RESISTANTGYPSUM BOARD
OPEN CELL CONT SPRAYFOAM INSULATION
2 1/2" MTL SUDSAT 16" O.C.
1' - 0
" VIF
3 1/8"
EXISTING HMFRAME TO REMAIN.
EXISTING HM DOORTO REMAIN.
ALIGN FACE OFGYPSUM BOARDWITH HM FRAME
PROVIDE BLOCKINGAS NECESSARY
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTTO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-00097313.0146.00
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
4/23
/201
3 1:
16:0
7 PM
\\be-
fs\u
ser d
ocum
ents
\pgo
ngal
\My
Doc
umen
ts\1
302-
13-0
1_N
EIU
_Doo
rRem
ain_
CEN
TRAL
_PG
onga
l.rvt
As indicated
CONSTRUCTION DETAILS
A400
VIVARIUM & MARINEORGANISMS RENOVATION
PG
4/24/2013
MP
1302-13-01
9 23
3" = 1'-0"COUNTER EDGE DETAIL
6
3" = 1'-0"BACKSPLASH DETAIL
7
1 1/2" = 1'-0"VENT THROUGH ROOF- TYP.
3
3" = 1'-0"FLOORING DETAIL
4 1 1/2" = 1'-0"ROOF HATCH DETAIL
1
1 1/2" = 1'-0"ROOF EXHAUST FAN DETAIL
20 6" 1'
0 6" 1'
0 6" 1'
0 3" 6"
0 3" 6"
0 3" 6"
0 6" 1' 1 1/2" = 1'-0"ENLARGED PLAN OF DIVIDER
8
1 1/2" = 1'-0"DIVIDER SECTION
9
0 6" 1'
0 6" 1'
1 1/2" = 1'-0"DIVIDER PANEL
100 3" 6"
1 1/2" = 1'-0"EXISTING JAMB DETAIL
5
Revision ScheduleNo. Date Description
1 4/24/2013 ISSUED FOR BID
3 4 5 6
A
3"SAN 3"SAN 3"SAN
3"SAN 3"SAN
2" V UP
2" V DN
3" SAN DN
3" SAN DN
3/4" HW
3/4" CW
3/4" CW
3/4" HW
2 1/2" SAN
3/4" S
1/2" A
3/4" HW
3/4" CW
1/2" DIW3/4" HW3/4" CW
3/4" CW
3"S
AN
1 1
/2"S
AN
3/4" S1/2" A3/4" HW3/4" CW
3/4" CW
3/4" S
1/2" A
3/4" HW
3/4" CW
3/4" S1/2" A3/4" HW3/4" CW
3/4" S1/2" A3/4" HW3/4" CW
STAIRS 211 210
6
6
1 1/2"CW1 1/4"HW
1 1/2"CW1 1/4"HW
COLD WATER - POTABLECW
HOT WATER - POTABLEHW
SANITARY DRAINAGESAN
VENTV
PIPE CAP
PIPE DOWN
PIPE UP OR UP/DOWN
PIPE SERVING FIXTURE ON FLOOR ABOVE.(EXAMPLE: FD = FLOOR DRAIN)
FD
ABOVE FINISHED FLOORAFF
BFP BACKFLOW PREVENTER
CO CLEANOUT
EMERGENCY EYEWASHEE
FLOOR DRAINFD
MIXING VALVEMV
NC NEW CONNECTION
SINKSK
VTR VENT THROUGH ROOF
PLUMBING SYMBOLS LISTSYMBOL: DESCRIPTION:
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW
NEW CONNECTION
PLUMBING CONTRACTORP.C.
SHUTOFF VALVE NORMALLY OPEN
SOLUTIONS
AIRA
GENERAL PLUMBING NOTES:1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, PIPING,
ETC. ARE DIAGRAMMATIC AND MAY NOT ALWAYS REFLECTACTUAL INSTALLATION CONDITIONS. DRAWINGS SHOWTHE GENERAL ARRANGEMENT OF ALL DUCTWORK, PIPING,EQUIPMENT, ETC., AND MAY NOT INCLUDE ALL OFFSETSAND FITTINGS REQUIRED FOR COMPLETE INSTALLATION.THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY ASACTUAL BUILDING CONSTRUCTION AND THE WORK OFOTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS ANDCLEARANCES FROM ARCHITECTURAL, STRUCTURAL,SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS ORPHYSICALLY AT SITE. READ ALL SPECIFICATIONS. REVIEWALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. LAYOUT AND COORDINATE ALL WORK WITH ALL OTHERTRADES PRIOR TO INSTALLATION TO PROVIDECLEARANCES REQUIRED FOR OPERATION, MAINTENANCE,CODE COMPLIANCE, AND TO VERIFY NON-INTERFERENCEWITH OTHER WORK. DO NOT FABRICATE PRIOR TOVERIFICATION OF NECESSARY CLEARANCES FOR ALLTRADES. BRING ANY INTERFERENCES OR CONFLICTS TOTHE ATTENTION OF THE ARCHITECT/ ENGINEER BEFOREPROCEEDING WITH ANY FABRICATION OR EQUIPMENTORDERS.
4. CONTRACTOR IS RESPONSIBLE FOR REVIEW OF SPACEREQUIREMENTS OF EQUIPMENT SPECIFIED ORSUBSTITUTED AND MAKING REASONABLEACCOMMODATIONS IN LAYOUT AND POSITIONING TOPROVIDE PROPER ACCESS.
5. ANY CHANGES THAT ARE REQUIRED TO ELIMINATECONFLICTS AND RESULT FROM A FAILURE TOCOORDINATE SHALL BE MADE BY THE CONTRACTORWITHOUT ADDITIONAL COST OR EXPENSE TO THE OWNER.
6. CAULK ALL PIPE PENETRATIONS OF FULL HEIGHT NON FIRERATED WALLS, PARTITIONS, FLOORS AND ROOFASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISETRANSMISSION FROM ONE ROOM TO ANOTHER AND TOPROVIDE THE DESIRED NC LEVELS WITHIN THE ROOMS.
7. CONTRACTOR IS RESPONSIBLE FOR ALL COSTASSOCIATED WITH ELECTRICAL CHANGES REQUIRED FOREQUIPMENT DIFFERENT THAN THE BASIS OF DESIGN.
PLUMBING DEMOLITION NOTES:1. THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE
OF DEMOLITION WORK REQUIRED AND DO NOT INDICATEEVERY PIPE OR PIECE OF EQUIPMENT THAT MUST BEREMOVED. ACCESSIBILITY OF EQUIPMENT AND SYSTEMSIS NOT SHOWN NOR SHOULD IT BE INFERRED. THECONTRACTOR SHALL VISIT THE SITE PRIOR TOSUBMITTING A BID AND VERIFY EXISTING CONDITIONS.
2. CONTRACTOR IS RESPONSIBLE FOR ALL COSTASSOCIATED WITH CEILING SYSTEM DISASSEMBLY ANDREASSEMBLY TO ACCOMMODATE THIS WORK.CONTRACTOR TO SALVAGE, STORE, AND REINSTALL ALLCEILING MOUNTED DEVICES.
3. CONTRACTOR IS RESPONSIBLE FOR PATCHING ALLPENETRATIONS CREATED BY REMOVAL OF EQUIPMENT,DUCTWORK, PIPING, ETC. TO MATCH EXISTING. REPAIRADJACENT CONSTRUCTION AND FINISHES DAMAGEDDURING DEMOLITION AND EXTENSION WORK. PATCH TOMATCH ORIGINAL CONSTRUCTION. VERIFY ALTERNATIVEOR SPECIAL REPAIR METHODS WITHARCHITECT/ENGINEER BEFORE PROCEEDING WITHDEMOLITION.
4. CONTRACTOR IS RESPONSIBLE FOR ALL MODIFICATIONSTO THE EXISTING PLUMBING PIPING, HVAC PIPING, ANDDUCTWORK NECESSARY TO PERMIT THE INSTALLATIONOF NEW WORK.
5. PROVIDE TEMPORARY CONNECTIONS TO MAINTAINEXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION.
6. EXTEND EXISTING INSTALLATIONS USING MATERIAL ANDMETHODS COMPATIBLE WITH EXISTING MECHANICALINSTALLATIONS, OR AS SPECIFIED FOR INTENDEDSERVICE.
7. EXISTING PLUMBING SYSTEM: MAINTAIN SERVICE TO ALLPLUMBING FIXTURES UNTIL NEW PIPING IS INSTALLED.OBTAIN PERMISSION FROM OWNER AT LEAST 72 HOURSBEFORE SHUTTING DOWN SYSTEM FOR ANY REASON.MAKE CHANGEOVER TO NEW PIPING WITH MINIMUMOUTAGE. COORDINATE EXACT TIME WITH OWNER.
8. REMOVE, RELOCATE, AND EXTEND EXISTINGINSTALLATIONS TO ACCOMMODATE NEWCONSTRUCTION.
9. REMOVE ABANDONED PIPING TO SOURCE OF SUPPLYAND/OR MAIN LINES AND CAP OR MAKE READY FORRECONNECTION IF SERVICE IS EXTENDED AS PART OFNEW WORK.
10. CUT PIPING ABOVE CEILINGS, BELOW FLOORS, ANDBEHIND WALLS. CAP REMAINING LINES. REMOVE ALLASSOCIATED CLAMPS, HANGERS, SUPPORTS, ETC.,ASSOCIATED WITH PIPING REMOVAL.
11. MECHANICAL ITEMS REMOVED AND NOT RELOCATEDREMAIN THE PROPERTY OF THE OWNER. THECONTRACTOR SHALL BE RESPONSIBLE FOR THEDISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TOREUSE OR RETAIN FOR MAINTENANCE PURPOSES.
PLUMBING FIXTURE ROUGH-IN SCHEDULE
FIXTURE DESCRIPTIONDOMESTIC
C.W.(NOTE 3)
DOMESTICH.W.
(NOTE 3)
SANITARY(NOTE 3)
VENT(NOTE 3)
REMARKS
SINK 1/2" 1/2" 1 1/2" 1 1/2" NOTE 1 & 2
FLOOR DRAIN - - 3" 1 1/2" HUB DRAIN
NOTES:
1. SANITARY RISER UP IN WALL TO FIXTURE SHALL BE A MINIMUM OF 2".2. 1/2" CW AND HW APPLIES ONLY TO THE FINAL VERTICAL RISE-DROP TO EACH FIXTURE. BRANCH PIPING TO VERTICAL
RISE-DROP SHALL BE A MINIMUM OF 3/4" INCH UNLESS NOTED OTHERWISE.3. SIZES SHOWN ARE MINIMUMS. SIZES SHOWN ON THE DRAWING THAT ARE LARGER THAN THE SIZES LISTED IN THE
SCHEDULE SHALL DICTATE THE ROUGH-IN SIZE.
EMERGENCY EYEWASH 3/4" TW AFTER MIXING VALVE- -3/4" 3/4"
DI WATER
1/2"
-
-
PRE-RINSE UNIT -- -1/2" 1/2" -
SUA-1 1/2" 1/2" - - --
CWF-1 -1/2" 1/2" - - -
3 4 5 6
A
B
BIO ANIMALLABS
335
PSYCHMARINE LAB
333
PSYCHMARINE LAB
327
CORRIDOR
383
GREENHOUSE
345
1
3
1
1 2
2
FDFD
3/4" HW
3/4" CW
3/4" HW
3/4" CW
2 3/4" CW3/4" HW3/4" CW3/4" CW
2
2FD
4
DEMOLISH SINK. SINK DRAINSPILLS TO EXISTING FLOORDRAIN.
3/4" S1/2" A3/4" HW3/4" CW
3/4" S1/2" A3/4" HW3/4" CW
3/4" S3/4" A3/4" HW3/4" CW
33" SAN DN
3/4" S3/4" A3/4" HW3/4" CW
5
7
FD FD
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
As indicated
SECOND FLOOR PLAN - PLUMBING- DEMOLITION
PD100
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
NO R HT
1/4" = 1'-0"1SECOND FLOOR PLAN - PLUMBING - DEMOLITION
GENERAL PLUMBING NOTES
1.
2.
COORDINATE SYSTEM SHUT DOWN(S) WITH OWNER.
CONTRACTOR SHALL CUT AND PATCH FLOOR AS REQUIRED FORINSTALLATION OF NEW PLUMBING.
#KEYNOTES
1.
2.
3.
4.
5.
6.
7.
DISCONNECT AND REMOVE EXISTING PLUMBING FIXTURE. CUTBACK CW AND HW TO WALL AND CAP. DOMESTIC WATERRISERS LOCATED IN WALL TO BE ABANDONED IN PLACE.EXISTING FLOOR DRAINS TO REMAIN. REFER TO SECOND FLOORPLAN - PLUMBING - DEMOLITION SHEET PD201 FOR ADDITIONALDEMOLITION REQUIREMENTS.
CUT BACK EXISTING AIR AND SUCTION PIPING TO WALL ANDCAP. PIPING IN WALL SHALL BE ABANDONED IN PLACE.
DISCONNECT AND REMOVE EXISTING SINK. CUT BACK EXISTINGCW, HW, SANITARY AND VENT LINES FOR REMOVAL OF SINK.PREPARE PIPING FOR RECONNECTION. PROVIDE TEMPORARYCAPS ON PIPING UNTIL NEW TIE-IN IS READY. REFER TO NEWWORK FOR ADDITIONAL INFORMATION.
DISCONNECT AND REMOVE EXISTING PLUMBING FIXTURE.EXISTING CW AND HW PIPING TO BE REVISED. PROVIDETEMPORARY CAPS ON PIPING UNTIL NEW TIE-IN IS READY.REFER TO NEW WORK FOR ADDITIONAL INFORMATION.
CAREFULLY DISCONNECT AND REMOVE EXISTING SINK. SINK TOBE REINSTALLED. CUT BACK EXISTING CW, HW, SANITARY ANDVENT LINES FOR REMOVAL OF SINK. PREPARE PIPING FORRECONNECTION. PROVIDE TEMPORARY CAPS ON PIPING UNTILNEW TIE-IN IS READY. REFER TO NEW WORK FOR ADDITIONALINFORMATION.
CUT AND PREPARE FOR NEW CONNECTION. REFER TO NEWWORK FOR LOCATIONS OF FLOOR PENETRATION. COORDINATEEXACT LOCATION IN FIELD AND WITH ALL TRADES.
DEMOLISH EXISTING FLOOR DRAIN. CUT BACK PIPING TO BELOWFLOOR AND CAP OFF. REPAIR FLOOR TO MATCH SURROUNDINGSURFACES.
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
10
NO R HT
1/4" = 1'-0"2THIRD FLOOR PLAN - PLUMBING - DEMOLITION
REVISIONS
NO. DATE DESCRIPTION
3 4 5 6
A
3"SAN 3"SAN 3"SAN
3"SAN 3"SAN
2" V UP 2" V DN
3" SAN DN
3" SAN DN
3/4" HW
3/4" CW
3/4" CW
3/4" HW
2 1/2" SAN
3/4" S
1/2" A
3/4" HW
3/4" CW
1/2" DIW3/4" HW3/4" CW
1 1
/2"S
AN
3/4" CW
2" V UPFD
CAP CAP CAP
STAIRS 211 210
3" SAN UP TOSTAND PIPE
3/4" CW UP
2" V UP
FD FD FD
3/4
"CW
1/2
"HW
1/2
"A3
/4"S
3/4" CW
CAP(TYP.4)
CAP(TYP.4)
3/4
"CW
CAP(TYP.4)
CAP(TYP.4)
REFER TO 2/P1.00 FORPIPE SUPPORT DETAIL(TYP.)
CAP(TYP.2)
FDFD
CAP(TYP.2)
3/4" HW UP
3/4" CW UP
3/4"HW 3/4"CW
CO
3/4"CW
THREADED ROD.(TYP.)
OVERSIZE HANGER TO ALLOWLONGITUDINAL PIPE EXPANSIONAND PIPE INSULATION TO PASSTHROUGH UNBROKEN. (TYP.)
UNI-STRUT OR EQUIVALENT
HIGH DENSITY INSULATION INSERTOR, FOR APPLICATIONS PERMITTEDIN SPEC SECTION 22 05 29-PLUMBING,STEEL SADDLE FILLED WITHINSULATION. (TYP.)
THREADED ROD.(TYP.)
PIPE INSULATION(TYP.)
INSULATION SHIELD (TYP.)
INSULATION SHIELD
INSTALL CLAMP ON ALLPIPES LESS THAN 4"Ø
THREADED ROD
INSULATION
CLEVIS HANGER
HIGH DENSITY INSULATION INSERTOR, FOR APPLICATIONS PERMITTEDIN SPEC SECTION 22 05 29-PLUMBING,STEEL SADDLE FILLED WITHINSULATION.
NOTES:
1. REFER TO SPECIFICATION SECTIONS 22 05 29-PLUMBING &SECTION 22 07 19-PLUMBING.
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
As indicated
SECOND FLOOR PLAN - PLUMBING
P100
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
NO R HT
1/4" = 1'-0"1SECOND FLOOR PLAN - PLUMBING
GENERAL DEMOLITION NOTES
1.
2.
COORDINATE SYSTEM SHUT DOWN(S)WITH OWNER.
CONTRACTOR SHALL CUT AND PATCHFLOORS AND WALLS AS REQUIRED FORINSTALLATION OF NEW PLUMBING.
NO SCALE2PIPE SUPPORT DETAIL
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
11
REVISIONS
NO. DATE DESCRIPTION
3 4 5 6
A
B
FD-1
4
3" STAND PIPETO 12" AFF.
BFP-1
BFP-1
6
6
5
5
3/4"CW
3/4
"CW
2" V UP TO4" VTR
FDFD
2"V
2"V
FD
CAP(TYP.4)
CAP(TYP.4)
CAP(TYP.4)
CAP(TYP.2)
WD-1
CWF-1
SK-1
1
ST-1
7
EE-1
3
SUA-1
2
8 SUA-1
2
SK-2
1
9
EE-1
10
REFER TO 2/P201 FORWASHDOWN AND SILLDETAIL (TYP.)
CAP(TYP.4)
10
103
10
FD
PSYCH MARINE DIAGONISTIC LAB
327
PSYCH MARINE HOUSING
333
ANIMAL HOUSING 1
335 A
PROCEDURE LAB
335
ANIMAL HOUSING 2
335 B
3/4" CW DOWN
3/4" HW DOWN
THE SYMBOLS AND THE MATERIAL LIST ARE FOR THE CONVENIENCE OF THE CONTRACTOR.CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR FULLYOPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT.
CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE, BUT ARE GIVEN AS AN AID TO THECONTRACTOR AND TO INDICATE THE QUALITY REQUIRED. CONTRACTOR IS RESPONSIBLE FORCOMPLETE DESCRIPTION OF MATERIAL ON THESE DRAWINGS AND IN THE SPECIFICATIONSBEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES PRECEDENCE OVER THECATALOG NUMBER. THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN.
CONTRACTOR SHALL VERIFY THAT FIXTURES SUPPLIED ARE APPROVED PER ALL APPLICABLESTATE, LOCAL AND GOVERNING AUTHORITIES.
FD-1
FLOOR DRAIN - CAST IRON BODY, NICKEL BRONZE ADJUSTABLE TOP, 6" ROUND, 3" BOTTOMOUTLET, FLASHING COLLAR, SURFACE MEMBRANE CLAMP, DEEP SEAL TRAP.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: ZURN (Z415)EQUIVALENT MANUFACTURER: SMITH (2005), WADE (1100), JOSAM (30000), WATTS (FD-100), MIFAB (F1100)
SK-1
SINK - SELF-RIMMING EXTRA DEEP SINGLE COMPARTMENT WITH FAUCET DECK, 18 GAUGESTAINLESS STEEL, 22" (SIDE-TO-SIDE) x 19" (FRONT-TO-BACK) OVERALL SIZE, 16" x 16" x 10"DEEP BOWL, COMPLETELY UNDERCOATED, 3-1/2" DIAMETER DRAIN OUTLET, REMOVABLESTAINLESS STEEL BASKET STRAINER WITH NEOPRENE STOPPER.
ACCESSORIES - 1-1/2" 17 GAUGE CHROME-PLATED BRASS TAILPIECE AND P-TRAP, QUARTER-TURN 3/8" CHROME-PLATED BRASS ANGLE SUPPLIES WITH LOOSE KEY STOPS, CHROME-PLATED SOFT COPPER SUPPLY LINES.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: THERMO SCIENTIFIC HAMILTON (52L9)EQUIVALENT MANUFACTURER: OR EQUAL BY ELKAY, JUST
SINK TRIM - FOOT CONTROL MIXING FAUCET, BRASS CONSTRUCTION, CHROME-PLATEDFINISH, DECK MOUNTED RIGID GOOSENECK SPOUT, 6" REACH, AERATOR, FLOOR MOUNTDOUBLE SELF-CLOSING PEDAL VALVE[S] AND LOOSE KEY STOPS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: DELTA (54T5)EQUIVALENT MANUFACTURER: CHICAGO FAUCET (625/626), T&S BRASS (B-0502/B-0520),ZURN (Z85500/Z821B0)
MAXIMUM FLOW TO BE 2.2 GPM IN COMPLIANCE WITH ENERGY POLICY ACT OF 1992 ANDASME/ANSI STANDARD A112.18.1M. PROVIDE RESTRICTIVE DEVICE AS REQUIRED. PROVIDEWITH AIR CHAMBERS ON BOTH HOT AND COLD WATER SUPPLY LINES.
MIXING VALVE - REMOTE ANTI-SCALD THERMOSTATIC MIXING VALVE FOR TEMPERED WATERCONTROL, ALL BRONZE/BRASS CONSTRUCTION, ROUGH FINISH, THREADED INLETS, TAMPERRESISTANT SETPOINT.
CABINET - SURFACE MOUNTED 18 GAUGE STAINLESS STEEL CABINET WITH 16 GAUGE LOCKINGDOOR TO ENCLOSE VALVE, INLET STOPS, OUTLET THERMOMETER, AND OUTLET VALVES.
2.2 GPM OUTPUT. UNIT TO MIX 120°F HOT WATER SUPPLY AND 40°F COLD WATER SUPPLY FOR110°F OUTLET. UNIT SHALL CONFORM TO THE REQUIREMENTS OF ASSE 1070 AND BE ASSE1070 APPROVED AND LISTED FOR USE IN ILLINOIS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: WATTS (USG-B)EQUIVALENT MANUFACTURER: APOLLO (34D), POWERS (E480), LEONARD (170)
SK-2
SINK - SELF-RIMMING EXTRA DEEP DOUBLE COMPARTMENT WITH FAUCET DECK, 18GAUGE STAINLESS STEEL, COMPLETELY UNDERCOATED, 37" (SIDE-TO-SIDE) x 22" (FRONT-TO-BACK) OVERALL SIZE, EACH COMPARTMENT 16" x 16" x 10 1/2" DEEP, 3-1/2" DIAMETERDRAIN OUTLET, REMOVABLE STAINLESS STEEL BASKET STRAINERS AND NEOPRENESTOPPERS.
ACCESSORIES - 1-1/2" 17 GAUGE CHROME-PLATED BRASS TAILPIECE AND P-TRAP,QUARTER-TURN 3/8" CHROME-PLATED BRASS ANGLE SUPPLIES WITH LOOSE KEY STOPS,CHROME-PLATED SOFT COPPER SUPPLY LINES.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: THERMO SCIENTIFIC HAMILTON (52L9)EQUIVALENT MANUFACTURER: OR EQUAL BY ELKAY, JUST
SINK TRIM - SENSOR OPERATED MIXING FAUCET, BRASS CONSTRUCTION, CHROME-PLATED FINISH, GOOSENECK SPOUT, 6" REACH, AERATOR, ADJUSTABLE SENSOR EYE,ADJUSTABLE TEMPERATURE CONTROL, MANUAL OVERRIDE, VANDAL-RESISTANTCONTROLS AND POWER CABLES.
ACCEPTABLE MANUFACTURERS: HYDROTEK (4000C)
ELECTRICAL REQUIREMENTS - 120V RECEPTACLE
MAXIMUM FLOW TO BE 2.2 GPM IN COMPLIANCE WITH ENERGY POLICY ACT OF 1992 ANDASME/ANSI STANDARD A112.18.1M. PROVIDE RESTRICTIVE DEVICE AS REQUIRED. PROVIDEWITH AIR CHAMBERS ON BOTH HOT AND COLD WATER SUPPLY LINES.
MIXING VALVE - REMOTE ANTI-SCALD THERMOSTATIC MIXING VALVE FOR TEMPEREDWATER CONTROL, ALL BRONZE/BRASS CONSTRUCTION, ROUGH FINISH, THREADEDINLETS, TAMPER RESISTANT SETPOINT.
CABINET - SURFACE MOUNTED 18 GAUGE STAINLESS STEEL CABINET WITH 16 GAUGELOCKING DOOR TO ENCLOSE VALVE, INLET STOPS, OUTLET THERMOMETER, AND OUTLETVALVES.
2.2 GPM OUTPUT. UNIT TO MIX 120°F HOT WATER SUPPLY AND 40°F COLD WATER SUPPLYFOR 110°F OUTLET. UNIT SHALL CONFORM TO THE REQUIREMENTS OF ASSE 1070 AND BEASSE 1070 APPROVED AND LISTED FOR USE IN ILLINOIS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: WATTS (USG-B)EQUIVALENT MANUFACTURER: APOLLO (34D), POWERS (E480), LEONARD (170)
PLUMBING MATERIAL LIST
EE-1
EMERGENCY EYE WASH - SWIVEL, DECK MOUNTED ADJACENT TO SINK, TWIN SPRAY HEADSWITH CAPS AND RETAINING CHAINS/STRAPS, BRASS SUPPLY ARMS, INTEGRAL FLOW CONTROLFITTING, BRASS PIPING AND FITTINGS, BRASS/BRONZE STAY OPEN BALL VALVE, SINGLE ACTIONACTIVATION BY METAL FLAG OR BY MOVING INTO POSITION, UNIVERSAL IDENTIFICATION SIGN,ANSI Z358.1-2009 COMPLIANT.
MINIMUM FLOW RATE OF 0.4 GPM AT 30 PSI. ACTIVATION TIME SHALL BE 1 SECOND OR LESS.BRASS/BRONZE PIPING, FITTINGS, AND VALVES SHALL BE CHROME-PLATED OR CHEMICAL-RESISTANT POWDER COATED. PROVIDE WITH OPTIONAL THERMOSTATIC MIXING VALVE G3600AS REQUIRED TO MEET ANSI Z358.1-2009 COMPLIANCE. INSTALL PER MANUFACTURERSRECOMMENDATIONS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: GUARDIAN G1895EQUIVALENT MANUFACTURER: OR EQUAL BY BRADLEY, ACORN SAFETY, OR SPEARMAN.
BFP-1
BACK FLOW PREVENTER - REDUCED PRESSURE ZONE, BRONZE OR FDA APPROVED EPOXYCOATED CAST IRON CONSTRUCTION, SIZE SAME AS PIPE, NON-CORROSIVE INTERNAL PARTS,STAINLESS STEEL SPRINGS, DIFFERENTIAL PRESSURE RELIEF VALVE BETWEEN SPRING-LOADED CHECK VALVES, SHUT-OFF VALVES ON INLET AND OUTLET OF UNIT, AIR GAP DRAINFITTING, TEST PORTS WITH SHUT-OFF VALVES, FACTORY TESTED, RATED FOR 175 PSI AT 33°FTO 140°F, 13 PSI (MAXIMUM) PRESSURE DROP AT 10 FPS, ALL PARTS TO BE SERVICEABLEWITHOUT REMOVING UNIT FROM LINE, APPROVED BY USC FCCC & HR, AWWA C511-92, ASSE1013, IAPMO AND SBCCI LISTED.
ACCEPTABLE MANUFACTURERS: WATTS (SERIES 909)
MOUNT AT 54" ABOVE FINISHED FLOOR. PROVIDE AND INSTALL BRONZE OR EPOXY COATEDSTRAINER UPSTREAM OF EACH UNIT. INSTALL ADDITIONAL VALVE UPSTREAM FROM EACHSTRAINER FOR SERVICING STRAINER. FLOW PRESSURE DROP CURVES SHALL BESUBMITTED.
BFP-2
BACK FLOW PREVENTER - DUAL CHECK, STAINLESS STEEL BODY, HEAVY DUTY FDA APPROVEDRUBBER DIAPHRAGMS, 3/8" SIZE, RATED FOR 150 PSI AT 33°F, APPROVED BY ASSE 1032.
ACCEPTABLE MANUFACTURERS: WATTS (SD-2)
ST-1
SINK TRIM - FOOT CONTROL MIXING FAUCET, BRASS CONSTRUCTION, CHROME-PLATED FINISH,DECK MOUNTED RIGID GOOSENECK SPOUT, 6" REACH, AERATOR, FLOOR MOUNT DOUBLESELF-CLOSING PEDAL VALVE[S] AND LOOSE KEY STOPS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: DELTA (54T5)EQUIVALENT MANUFACTURER: CHICAGO FAUCET (625/626), T&S BRASS (B-0502/B-0520),ZURN (Z85500/Z821B0)
MAXIMUM FLOW TO BE 2.2 GPM IN COMPLIANCE WITH ENERGY POLICY ACT OF 1992 ANDASME/ANSI STANDARD A112.18.1M. PROVIDE RESTRICTIVE DEVICE AS REQUIRED. PROVIDEWITH AIR CHAMBERS ON BOTH HOT AND COLD WATER SUPPLY LINES.
MIXING VALVE - REMOTE ANTI-SCALD THERMOSTATIC MIXING VALVE FOR TEMPERED WATERCONTROL, ALL BRONZE/BRASS CONSTRUCTION, ROUGH FINISH, THREADED INLETS, TAMPERRESISTANT SETPOINT.
CABINET - SURFACE MOUNTED 18 GAUGE STAINLESS STEEL CABINET WITH 16 GAUGE LOCKINGDOOR TO ENCLOSE VALVE, INLET STOPS, OUTLET THERMOMETER, AND OUTLET VALVES.
2.2 GPM OUTPUT. UNIT TO MIX 120°F HOT WATER SUPPLY AND 40°F COLD WATER SUPPLY FOR110°F OUTLET. UNIT SHALL CONFORM TO THE REQUIREMENTS OF ASSE 1070 AND BE ASSE1070 APPROVED AND LISTED FOR USE IN ILLINOIS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: WATTS (USG-B)EQUIVALENT MANUFACTURER: APOLLO (34D), POWERS (E480), LEONARD (170)
PLUMBING MATERIAL LIST
CWF-1
WASHING MACHINE FIXTURE - GALVANIZED STEEL ENCLOSURE, ANGLE VALVE WITH 1/4"COMPRESSION OUTLET. PROVIDE BFP-2 AND 1/4" SOFT COPPER LINE OFF VALVE AND READYCONNECTION TO FISH TANK SYSTEM.
ACCEPTABLE MANUFACTURERS: GUY GRAY (BIM875)
SUA-1
DESCRIPTION: PRE-RINSE SPRAY UNIT ASSEMBLY - SINGLE HOLE DECK MOUNTED PRE-RINSEFITTING, CHROME PLATED SOLID BRASS CONSTRUCTION. 1.0 GPM @ 60 PSI WATERCONSERVING PRE-RINSE SPRAY VALVE. 2-3/8" METAL LEVER HANDLE(S) WITH EIGHT POINTTAPERED BROACH AND SECURED BLUE AND RED BUTTONS. COMPRESSION CARTRIDGE,OPENS AND CLOSES 90°, CLOSES WITH WATER PRESSURE, FEATURES SQUARE TAPEREDSTEM. 3 1/2" INLET TEE CONNECTION WITH 1/4" NPT CHECK STOP TAILPIECES. 44" FLEXIBLESTAINLESS STEEL HOSE WITH INSULATED HANDLE. E23JKCP IN-LINE BACK FLOW PREVENTER TOPREVENT THE FLOW OF CONTAMINATED WATER BACK INTO THE POTABLE WATER SUPPLY. PIPESTRAP AND HOOK ASSEMBLY. ASME A112.18.1/CSA B125.1 CERTIFIED.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: CHICAGO FAUCETS (919-VBH590)EQUIVALENT MANUFACTURER: OR EQUAL BY ZURN, ELKAY.
MIXING VALVE - REMOTE ANTI-SCALD THERMOSTATIC MIXING VALVE FOR TEMPERED WATERCONTROL, ALL BRONZE/BRASS CONSTRUCTION, ROUGH FINISH, THREADED INLETS, TAMPERRESISTANT SETPOINT.
CABINET - SURFACE MOUNTED 18 GAUGE STAINLESS STEEL CABINET WITH 16 GAUGE LOCKINGDOOR TO ENCLOSE VALVE, INLET STOPS, OUTLET THERMOMETER, AND OUTLET VALVES.
2.2 GPM OUTPUT. UNIT TO MIX 120°F HOT WATER SUPPLY AND 40°F COLD WATER SUPPLY FOR110°F OUTLET. UNIT SHALL CONFORM TO THE REQUIREMENTS OF ASSE 1070 AND BE ASSE 1070APPROVED AND LISTED FOR USE IN ILLINOIS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: WATTS (USG-B)EQUIVALENT MANUFACTURER: APOLLO (34D), POWERS (E480), LEONARD (170)
WD-1
DESCRIPTION: WASHDOWN AND SILL - WALL MOUNTED 6" CENTER HOSE REELS HOSE REELASSEMBLY WITH FITTING . 2.5 GPM @ 60 PSI HOSE REEL SPRAY VALVE SPRAY. 3" METALCROSS HANDLE(S) WITH EIGHT POINT TAPERED BROACH AND SECURED BLUE AND REDBUTTONS. COMPRESSION CARTRIDGE, OPENS AND CLOSES 90°, CLOSES WITH WATERPRESSURE, FEATURES SQUARE TAPERED STEM. 1/2" NPT FEMALE THREAD INLETS.RETRACTABLE 35 FT. x 3/8" I.D. RUBBER HOSE. EXPOSED TWO VALVE FITTING. SHUTOFFVALVE. STRAIGHT STOP VALVES. PROVIDE WITH INLINE BACKFLOW DEVICE, WATTS MODELSD-2 OR EQUAL PER MANUFACTURERS RECOMMENDATIONS AND PER LOCAL CODEREQUIREMENTS.
ACCEPTABLE MANUFACTURERS:BASE OF DESIGN MANUFACTURER: CHICAGO FAUCETS (535-NF)EQUIVALENT MANUFACTURER: OR EQUAL BY T&S, ARMSTONG
1/2 NPTFEMALE INLETS
45-LKC CHECKVALVES
1/2 NPT FEMALE INLETSAND OUTLETS
BUSHED TO3/8 NPT
3/8 NPT FEMALEINLET
FLEX UNION.RECOMMENDED
3/4 GPM BLEEDER TO REDUCEBACK PRESSURE ON VACUUMBREAKER WHEN SHUT-OFFAND/OR MIXING VALVE IS OPENAND PRE-RISEN VALVE ISCLOSED.
3/8 NPT FEMALEINLET ANDOUTLET
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
As indicated
THIRD FLOOR PLAN - PLUMBING
P201
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
NO R HT
1/4" = 1'-0"1THIRD FLOOR PLAN - PLUMBING
GENERAL DEMOLITION NOTES
1.
2.
COORDINATE SYSTEM SHUT DOWN(S)WITH OWNER.
CONTRACTOR SHALL CUT AND PATCHFLOORS AND WALLS AS REQUIREDFOR INSTALLATION OF NEW PLUMBING.
#KEYNOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
EXTEND HW AND CW PIPING TO SINKTRIM AND MAKE ALL REQUIREDCONNECTIONS PER MANUFACTURERSRECOMMENDATIONS. PROVIDE HOTWATER MIXING VALVE BEFORE FIXTURECONNECTION. LOCATE VALVE INSURFACE MTD. CABINET BELOW SINK.EXTEND EXISTING SANITARY AND VENTLINES TO SINK AND MAKE ALL REQUIREDCONNECTIONS. REFER TO PLUMBINGMATERIAL LIST FOR ADDITIONALINFORMATION AND REQUIREMENTS.
EXTEND HW AND CW PIPING TO SPRAYUNIT ASSEMBLY TRIM AND MAKE ALLREQUIRED CONNECTIONS PERMANUFACTURERS RECOMMENDATIONS.PROVIDE HOT WATER MIXING VALVEBEFORE FIXTURE CONNECTION. LOCATEVALVE IN SURFACE MTD. CABINETBELOW SINK. REFER TO SPRAY UNITASSEMBLY DESCRIPTION IN PLUMBINGMATERIAL LIST FOR ADDITIONALINFORMATION AND REQUIREMENTS.
EXTEND HW AND CW PIPING TOEMERGENCY EYEWASH TRIM AND MAKEALL REQUIRED CONNECTIONS PERMANUFACTURERS RECOMMENDATIONS.PROVIDE HOT WATER MIXING VALVEBEFORE FIXTURE CONNECTION. LOCATEVALVE IN SURFACE MTD. CABINETBELOW SINK. REFER TO EMERGENCYEYEWASH DESCRIPTION IN PLUMBINGMATERIAL LIST FOR ADDITIONALINFORMATION AND REQUIREMENTS.
EXTEND HW AND CW PIPING TOEXISTING EMERGENCY EYEWASH TRIMAND MAKE ALL REQUIRED CONNECTIONSPER MANUFACTURERSRECOMMENDATIONS. PROVIDE MIXINGVALVE EQUIVALENT TO EE-1DESCRIPTION IF NOT CURRENTLYINCLUDED.
DISCHARGE HUMIDIFIER DRAIN DOWNTO STAND PIPE. PROVIDE 1" MINIMUMAIR GAP ABOVE STANDPIPE.
PROVIDE 3/4" CW CONNECTION FORHUMIDIFICATION UNIT. ROUTE DOWNWALL AND CONNECT TO BACKFLOWPREVENTER BFP-1 PRIOR TOCONNECTION TO HUMIDIFIER PERMANUFACTURERS RECOMMENDATIONS.INSTALL BACKFLOW PREVENTERAPPROXIMATELY 54" AFF.
REINSTALL EXISTING SINK IN NEW CASEWORK. EXTEND HW AND CW PIPING TOSINK TRIM AND MAKE ALL REQUIREDCONNECTIONS PER MANUFACTURERSRECOMMENDATIONS. PROVIDE HOTWATER MIXING VALVE BEFORE FIXTURECONNECTION. LOCATE VALVE INSURFACE MTD. CABINET BELOW SINK.EXTEND EXISTING SANITARY AND VENTLINES TO SINK AND MAKE ALL REQUIREDCONNECTIONS. REFER TO PLUMBINGMATERIAL LIST FOR ADDITIONALINFORMATION AND REQUIREMENTS.
EXTEND CW LINE TO COLD WATERFITTING. ROUTE RISER IN NEW WALL OFANIMAL HOUSING TO ROOM 335 B ANDTERMINATE IN BASE OF ENCLOSURE.OPEN EXISTING WALL TO ACCESS PIPINGAND INSTALL BOX. PATCH AND REPAIRWALL. REFER TO COLD WATER FITTINGDESCRIPTION IN PLUMBING MATERIALLIST FOR ADDITIONAL INFORMATION.
EXTEND EXISTING HW AND CW PIPINGTO WASHDOWN FIXTURE AND MAKE ALLREQUIRED CONNECTIONS PERMANUFACTURERS RECOMMENDATIONS.REFER TO WASHDOWN AND SILLDESCRIPTION IN PLUMBING MATERIALLIST FOR ADDITIONAL INFORMATION ANDREQUIREMENTS.
EXTEND HW AND CW WATER LINES OFFMAIN RISER, FEED TO ADJACENT SINK TOSERVE EYEWASH OR SPRAY UNITASSEMBLY.
NO SCALE2WASHDOWN AND SILL DETAIL
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
12
REVISIONS
NO. DATE DESCRIPTION
S1
3 4 5 6
A
B
BIO ANIMALLABS
335
PSYCHMARINE LAB
333
PSYCHMARINE LAB
327
CORRIDOR
383
GREENHOUSE
345
10
x6
16
x8
16x7 14x7
14
x7
20x8
16x10
10
x6
10x610x6
1 1
1
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW
EXISTING DUCT TO REMAIN
EXISTING DUCT TO BE REMOVED
NEW DUCT
FLEX DUCT CONNECTION
MANUAL VOLUME DAMPER
SUPPLY/OUTSIDE AIR DUCT SECTION
EXHAUST/RELIEF AIR DUCT SECTION
CD-16/115
AIR TERMINAL PROPERTIES SYMBOLNECK SIZE/CFM
###
TERMINAL AIR BOX w/REHEAT COIL(REFER TO SCHEDULE)
MECHANICAL SYMBOLS LISTSYMBOL: DESCRIPTION:
NEW CONNECTION
SHUTOFF VALVE NORMALLY OPEN
EA EXHAUST/RELIEF AIR
NC NEW CONNECTION
THERMOSTAT/SENSORT
HEATING WATER RETURNHWR
HEATING WATER SUPPLYHWS
PIPE CAP
PIPE DOWN
PIPE UP OR UP/DOWN
HUMIDISTAT SENSORH
"WYE" - STRAINER
BALANCING VALVE (NO. INDICATES GPM)0.5
CONTROL VALVE (TWO-WAY)
DRAIN VALVE WITH HOSE CONNECTION AND CAP
UNION/FLANGE
GENERAL MECHANICAL NOTES:1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT,
DUCTWORK, PIPING, ETC. ARE DIAGRAMMATIC AND MAYNOT ALWAYS REFLECT ACTUAL INSTALLATIONCONDITIONS. DRAWINGS SHOW THE GENERALARRANGEMENT OF ALL DUCTWORK, PIPING, EQUIPMENT,ETC., AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGSREQUIRED FOR COMPLETE INSTALLATION. THEDRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUALBUILDING CONSTRUCTION AND THE WORK OF OTHERSWILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS ANDCLEARANCES FROM ARCHITECTURAL, STRUCTURAL,SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS ORPHYSICALLY AT SITE. READ ALL SPECIFICATIONS. REVIEWALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. LAYOUT AND COORDINATE ALL WORK WITH ALL OTHERTRADES PRIOR TO INSTALLATION TO PROVIDECLEARANCES REQUIRED FOR OPERATION, MAINTENANCE,CODE COMPLIANCE, AND TO VERIFY NON-INTERFERENCEWITH OTHER WORK. DO NOT FABRICATE PRIOR TOVERIFICATION OF NECESSARY CLEARANCES FOR ALLTRADES. BRING ANY INTERFERENCES OR CONFLICTS TOTHE ATTENTION OF THE ARCHITECT/ENGINEER BEFOREPROCEEDING WITH ANY FABRICATION OR EQUIPMENTORDERS.
4. CONTRACTOR IS RESPONSIBLE FOR REVIEW OF SPACEREQUIREMENTS OF EQUIPMENT SPECIFIED ORSUBSTITUTED AND MAKING REASONABLEACCOMMODATIONS IN LAYOUT AND POSITIONING TOPROVIDE PROPER ACCESS.
5. ANY CHANGES THAT ARE REQUIRED TO ELIMINATECONFLICTS AND RESULT FROM A FAILURE TOCOORDINATE SHALL BE MADE BY THE CONTRACTORWITHOUT ADDITIONAL COST OR EXPENSE TO THEOWNER.
6. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULLHEIGHT NON FIRE RATED WALLS, PARTITIONS, FLOORSAND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENTNOISE TRANSMISSION FROM ONE ROOM TO ANOTHERAND TO PROVIDE THE DESIRED NC LEVELS WITHIN THEROOMS.
7. CONTRACTOR IS RESPONSIBLE FOR ALL COSTASSOCIATED WITH ELECTRICAL CHANGES REQUIRED FOREQUIPMENT DIFFERENT THAN THE BASIS OF DESIGN.
8. REFER TO ARCHITECTURAL REFLECTED CEILING PLANFOR EXACT LOCATIONS OF ALL CEILING MOUNTEDDEVICES.
9. TERMINAL AIR BOX (TAB) NUMBER OR REHEAT COILNUMBER IS SHOWN ADJACENT TO THERMOSTAT ONLYWHEN THE TAB OR COIL WHICH THE THERMOSTAT ISCONTROLLING IS AMBIGUOUS.
10. ALIGN LIGHT SWITCHES AND TEMPERATURE SENSORSWHEN IN CLOSE PROXIMITY TO EACH OTHER.
11. PROVIDE ACCESS DOORS AT ALL DUCT MOUNTEDEQUIPMENT.
MECHANICAL DEMOLITION NOTES:1. THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE
OF DEMOLITION WORK REQUIRED AND DO NOT INDICATEEVERY PIPE, DUCT, OR PIECE OF EQUIPMENT THAT MUSTBE REMOVED. ACCESSIBILITY OF EQUIPMENT ANDSYSTEMS IS NOT SHOWN NOR SHOULD IT BE INFERRED.THE CONTRACTOR SHALL VISIT THE SITE PRIOR TOSUBMITTING A BID AND VERIFY EXISTING CONDITIONS.
2. CONTRACTOR IS RESPONSIBLE FOR ALL COSTASSOCIATED WITH CEILING SYSTEM DISASSEMBLY ANDREASSEMBLY TO ACCOMMODATE THIS WORK.CONTRACTOR TO SALVAGE, STORE, AND REINSTALL ALLCEILING MOUNTED DEVICES.
3. CONTRACTOR TO COORDINATE WITH OWNER FOR ALLMECHANICAL SERVICE OUTAGES. EXISTING WATERSYSTEM: MAINTAIN EXISTING SYSTEM IN SERVICE UNTILNEW SYSTEM IS COMPLETE AND READY FOR SERVICE.DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS ANDCONNECTIONS. OBTAIN PERMISSION FROM OWNER ATLEAST 72 HOURS BEFORE PARTIALLY OR COMPLETELYDRAINING SYSTEM. MINIMIZE OUTAGE DURINGOPERATION.
4. CONTRACTOR IS RESPONSIBLE FOR PATCHING ALLPENETRATIONS CREATED BY REMOVAL OF EQUIPMENT,DUCTWORK, PIPING, ETC. TO MATCH EXISTING. REPAIRADJACENT CONSTRUCTION AND FINISHES DAMAGEDDURING DEMOLITION AND EXTENSION WORK. PATCH TOMATCH ORIGINAL CONSTRUCTION. VERIFY ALTERNATIVEOR SPECIAL REPAIR METHODS WITHARCHITECT/ENGINEER BEFORE PROCEEDING WITHDEMOLITION.
5. CONTRACTOR IS RESPONSIBLE FOR ALL MODIFICATIONSTO THE EXISTING HVAC PIPING AND DUCTWORKNECESSARY TO PERMIT THE INSTALLATION OF NEWWORK.
6. PROVIDE TEMPORARY CONNECTIONS TO MAINTAINEXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION.
7. EXTEND EXISTING INSTALLATIONS USING MATERIAL ANDMETHODS COMPATIBLE WITH EXISTING MECHANICALINSTALLATIONS, OR AS SPECIFIED FOR INTENDEDSERVICE.
8. REMOVE, RELOCATE, AND EXTEND EXISTINGINSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION.
9. REMOVE ALL ASSOCIATED CLAMPS, HANGERS, SUPPORTS,ETC., ASSOCIATED WITH PIPING AND DUCT REMOVAL.
10. DISCONNECT AND REMOVE MECHANICAL DEVICES ANDEQUIPMENT SERVING EQUIPMENT THAT HAS BEENREMOVED.
11. MAINTAIN ACCESS TO EXISTING MECHANICALINSTALLATIONS WHICH REMAIN ACTIVE. MODIFYINSTALLATION OR PROVIDE ACCESS PANEL ASAPPROPRIATE.
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
As indicated
THIRD FLOOR PLAN - MECHANICAL- DEMOLITION
MD101
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
NO R HT
1/4" = 1'-0"1THIRD FLOOR PLAN - MECHANICAL- DEMOLITION
GENERAL DEMOLITION NOTES
1.
2.
3.
CONTRACTOR SHALL COORDINATE EXISTING SYSTEM SHUTDOWNS WITH OWNER.
FIELD VERIFY ALL EQUIPMENT PRIOR TO DEMOLITION. REPORTANY DISCREPANCIES FOUND TO THE ARCHITECT ORENGINEERING TEAM.
DEMOLISH DUCTWORK WHERE INDICATED AND ALL ASSOCIATEDHANGERS, SUPPORTS, ANCHORS, AND INSULATION IN THEIRENTIRETY.
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
13
#KEYNOTES
1. CAP EXISTING DUCTWORK AND REINSULATE TO MATCHEXISTING.
REVISIONS
NO. DATE DESCRIPTION
S1 S1
S1
S1
S1
H
H
3 4 5 6
A
B
16x10
10x6
16x7 14x7
NC NC
TAB-333
CD-1
6/160
CD-1
12/390
CD-1
6/100
CD-1
6/100
TAB-335B
NC
NCNC
TAB-335A
TAB-335
10
ø
TAB-327
CD-1
8/225
NC
EG-1
22x22/225
EG-1
22x22/225
20x8
EG-1
22x22/125
NC
NC
EG-1
22x22/450
EG-1
22x22/125
10
x6
EF-11
REFER TO 1/M-500 FORBRANCH CONNECTIONSDETAIL.(TYP.)
REFER TO 2/M-500 FORDIFFUSER CONNECTIONDETAIL.(TYP.)
REFER TO 5/M-500FOR TERMINAL AIRBOX DETAIL.(TYP.)
14
x1
0
REFER TO 3/M-500 FORDUCT REINFORCEMENTDETAIL.(TYP.)
REFER TO 1/M-501 FOR LONGITUDINALSEAMS - RECTANGULAR DUCT DETAIL.(TYP.)
REFER TO 4/M-500 FORELBOW CONSTRUCTIONDETAIL.(TYP.)
PROCEDURE LAB
335
PSYCH MARINE HOUSING
333
PSYCH MARINE DIAGONISTIC LAB
327
ANIMAL HOUSING 2
335 B
ANIMAL HOUSING 1
335 A
2 3
E
F
G
H
J24x12 OUTSIDE
AIR LOUVER
16x10 SA DN
HU-1
S-7
CU-1S-5
T3
P-17
16x1
0
16x1
0
16x10
24
x8
2
EXISTING MECHANICAL EQUIPMENTSCHEDULE - FOR REFERENCE ONLY
S-7 EXISTING AIR HANDLING UNIT
FAN CAPACITY: 950 CFM @ 2.2 INCH TSP, 1 HP 208-3-60 MOTOR
COOLING COIL: 6 ROW, 14 FINS/INCH HALF CIRCUIT, DX EAT 95°F DB& 75°F WB, LAT 55°F DB & 54°F WB TOTAL COOLING67.7 MBH, SENSIBLE COOLING 41.0 MBH APD 0.92 INW.G.
HEATING COIL: 2 ROW, 8 FINS/INCH FULL CIRCUIT, EWT 200°F,9.1 GPM FLOW, 0.32 FT. HEAD W.P.D., EAT -10°F,LAT 80°F, 92 MBH CAPACITY, APD 0.93 INCHED W.G.
FILTERS: 2 INCH THICK THROW-AWAY TYPE
CV-1 EXISTING AIR COOLED CONDENSING UNIT
COOLING CAPACITY 68 MBH, R22 REFRIG., 40FSATURATED SUCTION TEMPERATURE, 7.2 KWCOMPRESSOR POWER INPUT, 1/2 HP, 1075 RPMCONDENSER FAN, 208-3-60.
P-17 EXISTING IN-LINE PUMP
CAPACITY: 10 GPM @ 21 FT HEAD, 1/4" HP,1750 RPM, 115-1-60 MOTOR.
HU-1 EXISTING ELECTRIC HUMIDIFIER (TO BE REMOVED)
MINIMUM CAPACITY: 5 LBS STEAM/HR. MAXIMUMCAPACITY: 30 LBS/HR. ELECTRICAL INPUT: 10 KW ATMAXIMUM OUTLET. 208-3-60.
3 4 5 6
A
B
TAB-327 TAB-333 TAB-335B TAB-335A
TAB-335
H-2
H-1
REFER TO 2/M-501 FOR PIPETHROUGH NON-FIRE RATEDWALL DETAIL.(TYP.)
REFER TO 3/M-501 FORHEATING COIL PIPINGDETAIL. (TYP.)
HWR
HWS
TAB-333 TAB-335TAB-334
TAB-335B
TAB-335A
3/4"HWS
3/4"HWR
PSYCH MARINE DIAGONISTIC LAB
327
PSYCH MARINE HOUSING
333
ANIMAL HOUSING 1
335 A
PROCEDURE LAB
335
ANIMAL HOUSING 2
335 B
CORRIDOR
383
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
As indicated
THIRD FLOOR PLAN - MECHANICAL
M101
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
NO R HT
1/4" = 1'-0"2THIRD FLOOR PLAN - VENTILATION
GENERAL VENTILATION NOTES
1.
2.
3.
4.
CONTRACTOR SHALL COORDINATEDUCTWORK AND EQUIPMENTLOCATIONS WITH ALL TRADES ANDEXISTING CONDITIONS.
CONTRACTOR SHALL COORDINATEEXISTING SYSTEM SHUT DOWNS WITHOWNER.
CUT AND PATCH WALLS AS REQUIREDFOR INSTALLATION OF DUCTWORK ANDPIPING.
ALL HOT WATER SUPPLY AND HOTWATER RETURN PIPING TO BE MINIMUM3/4" DIAMETER UNLESS INDICATEDOTHERWISE.
#KEYNOTES
1.
2.
3.
CONTRACTOR SHALL PROVIDE CURBADAPTOR TO EXISTING ROOF CURB TOMATCH THROAT DIMENSIONS OF NEWFAN. VERIFY EXACT SIZE AND OFFSETREQUIREMENTS IN FIELD. COORDINATESIZES WITH FAN MANUFACTURER.
CONTRACTOR SHALL DISCONNECT ANDREMOVE HUMIDIFIER LOCATED INPENTHOUSE. CUT BACK DOMESTICWATER FEED TO MAIN AND CAP.REMOVE ALL ASSOCIATED STEAMRELATED PIPING AND DISPERSIONMANIFOLD. REMOVE ALL POWER ANDCONTROL RELATED ACCESSORIES.
CONTRACTOR SHALL PROVIDE NEWDUCT MOUNTED AIRSTREAMTHERMOSTAT WHERE INDICATED.CONTRACTOR SHALL PROVIDE ALLNECESSARY CONTROLS, HARDWAREAND ACCESSORIES TO INTERLOCKWITH EXISTING AIR HANDLING UNIT S-7.UNIT SHALL MAINTAIN A LEAVING AIRTEMPERATURE OF 55°F. REFER TOCONTROLS SPECIFICATION 23 09 00 FORADDITIONAL INFORMATION.
NO R HT
1/8" = 1'-0"1PENTHOUSE FLOOR PLAN
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
14
NO R HT
1/4" = 1'-0"3THIRD FLOOR PLAN - PIPING
REVISIONS
NO. DATE DESCRIPTION
D1>D2
45 DEGREE
BUTT FLANGESTRAIGHT TAP
ENTRY Θ 45°45 DEGREE CONICAL
CLINCH LOCK
CORNER FILLERPIECE OR USEGASKET (TYP.)
45 DEGREE LEAD IN
NOTES:
1. DO NOT USE CONNECTIONS WITH SCOOPS.2. FIT ALL CONNECTIONS TO AVOID VISIBLE OPENINGS AND
SECURE THEM SUITABLY FOR THE PRESSURE CLASS.3. ADDITIONAL MECHANICAL FASTENERS ARE REQUIRED FOR
4"W.G. AND OVER.4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
DOVETAIL JOINT
LINED DUCT CONNECTION(NO EXPOSED LINER EDGES)
DUCT LINER
FLANGED
NOTE: STRAIGHT TAP WITH BUTTFLANGE FOR BRANCH AND TEECONNECTION IN RECTANGULAR DUCTSUNDER 1" PRESSURE CLASS ONLY.
ENTRY Θ 45°
D1
W
L
Θ
D2
(L = 4" OR W/4; WHICHEVER IS LARGER)
CEILING
STRUCTURE
NOTES:
1. TO ATTACH FLEX DUCT TO THE HARD DUCT, TAPE THE INNER LINER TO THEHARD DUCT THEN ATTACH WITH TWO NYLON TIE WRAPS; ONE FOR THEINNER LINER AND ONE FOR THE OUTER SHELL. FOLD THE OUTER SHELLINSIDE ITSELF SO IT HAS NEAT EDGES PRIOR TO TIE WRAPPING.
2. "SMARTFLOW" ELBOW (WWW.HARTANDCOOLEY.COM), THERMAFLEX"FLEXFLOW" (WWW.THERMAFLEX.BET/FLEXFLOW_ELBOW.PHP?AUD) AND"FLEXRIGHT" (WWW.TITUS-HVAC.COM) ARE ACCEPTABLE PRODUCTS FORDURABLE ELBOW SUPPORT.
FLEXIBLE DUCTMAX. LENGTH 6'-0"
HARD DUCT
TRIM STRAPS AFTERTIGHTENING
SUSPEND ELBOWWITH TIE
DRAW BANDS SNUG,WITHOUT CRUSHINGFLEXIBLE DUCT
PROVIDE DURABLEELBOW SUPPORT
DIFFUSER
1X DUCT DIAMETERMINIMUM STRAIGHTDUCT.
R
R
JOINTS AT C
ONVENIENT
JOINTS AT C
ONVENIENT
R
R
2ND INTERVAL
1ST INTERVAL
INTERMEDIATEREINFORCEMENT
NOTES:
1. 'R' IS AN ALLOWABLE REINFORCEMENT INTERVAL.2. TOP AND BOTTOM JOINTS MUST QUALIFY AS REINFORCEMENT3. DUCT SIZES 19" WIDE AND LARGER WHICH HAVE MORE THAN
10 SQ. FT. OF UNBRACED PANEL SHALL BE BEADED OR CROSSBROKEN UNLESS DUCT WILL HAVE INSULATION COVERING ORACOUSTICAL LINER. THIS REQUIREMENT IS APPLICABLE TO 20GAUGE OR LESS THICKNESS AND 3" W.G. OR LESS.
4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
INTERMEDIATEREINFORCEMENT
UNREINFORCED SIDE
INTERVALS NEED NOTNECESSARILY COINCIDEON ADJACENT SIDES
JOINT
JOINT
JOINT
JOINT
DUCT REINFORCED ON TWO SIDES
DUCT REINFORCED ON ALL SIDES
RECTANGULARMITERED ELBOW
WITH VANESTYPE RE2
RECTANGULARMITERED ELBOW
TYPE RE6
USE ONLY AS PART OF OFFSETSAND TRANSITIONS PER FIGURE4-7 TYPE 2 OR AS SHOWN ONDRAWINGS. OFFSETS ABOVE 30°SHALL BE TYPE RE1.
RECTANGULARRADIUS ELBOW
TYPE RE1
R/W = 1.0 (MINIMUM)R/W < 1.0 SHALL BE TYPE RE3
RECTANGULARRADIUS ELBOW WITH VANES
TYPE RE3
REFER TO SMACNA HVAC SYSTEMS DUCT DESIGN MANUAL, FOURTHEDITION, SECTION 5.14 "SPLITTER VANES" AND SMACNA HVAC DUCTCONSTRUCTION STANDARDS, THIRD EDITION, FIGURES 4-2 AND 4-9 ANDCHARTS 4-1 AND 4-1M. ELBOW SHALL HAVE THREE SPLITTER VANESAND r/W = 0.10 (R/W = 0.60) UNLESS NOTED OTHERWISE.
NOTES:
1. BEAD, CROSSBREAK, AND REINFORCE FLAT SURFACES AS IN STRAIGHT DUCT.2. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.3. DEFAULT ELBOW SHALL BE TYPE "RE1".4. ELBOW TYPES SHALL BE INSTALLED AS SHOWN AND NOT BE SUBSTITUTED
WITHOUT PERMISSION. EXCEPTION: RE1 OR RE3 MAY BE SUBSTITUTED FORRE2.
RECTANGULARRADIUS ELBOW WITH
SQUARE THROAT
NOT ALLOWED
RECTANGULAR / OVAL / ROUNDMITERED ELBOWWITHOUT VANES
TYPE RE4
NOT ALLOWED
OVAL / ROUNDRADIUS ELBOW
SMOOTH OR 5 GORE (MINIMUM)
R/W = 1.5 (MINIMUM)
W W
R
R
W
r R1 R
2
R R3
W
W
30°
EX
CE
ED
NO
T T
O
W
W
90°
90°
W
W
NOTES:
1. THIS DETAIL APPLIES ONLY TO TAPS OFF WRAPPED DUCTS.2. THIS DETAIL APPLIES TO TERMINAL AIR BOXES WITH ROUND INLETS AND
RECTANGULAR OUTLETS.3. DUCT LEADING TO TAB INLET MUST BE STRAIGHT FOR 1.5 DIAMETER
UPSTREAM.4. MAINTAIN VAPOR BARRIER FROM MAIN TO BRANCH DUCT.
NYLON TIE WRAP, TWO REQUIREDFOR EACH END OF FLEXIBLE DUCT(TOTAL 4). INSTALL ONE TIE WRAPTO SECURE THE INNER LINER ANDONE TO SECURE THE OUTER SHELL.(TYP.)
PRE-MANUFACTURED CONICALTAKE-OFF WITH SELF-ADHESIVENEOPRENE GASKET (EQUAL TOSHEET METAL CONNECTORSCONICAL E-Z TAP)
FASTEN WITH SELF-TAPPINGSHEETMETAL SCREWS (MIN. 4)
CUT DUCT OPENING TO MATCHLARGER TAKEOFF DIAMETER
INSULATED GALVANIZED DUCT
CUT HELIX AND INNER FABRIC HERE. SECUREWITH NYLON TIE. OVERLAP FLEX DUCT MINIMUMOF 2" ONTO RIGID DUCT. PROVIDE DUCTSEALER AT CONNECTION BETWEEN FLEX DUCTAND RIGID DUCT.
AIR FLOWTERMINAL AIR BOX
RECTANGULAR INSULATED DUCT
INSULATEDFLEX DUCT
INSULATED TRANSITION
REHEAT COIL (IF SCHEDULED),INSULATE PER SPECIFICATIONS.
3' MAX.
6" MIN.
. D
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
12" = 1'-0"
MECHANICAL DETAILS
M500
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
NO SCALE1BRANCH CONNECTIONS
NO SCALE2DIFFUSER CONNECTION DETAIL
NO SCALE3DUCT REINFORCEMENT DETAIL
NO SCALE4ELBOW CONSTRUCTION
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
15
NO SCALE5TERMINAL AIR BOX DETAIL (WRAPPED MAIN)
REVISIONS
NO. DATE DESCRIPTION
NOTES:
1. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
SEAM LOCATIONS
NUMBER OF SEAMS AND LOCATIONVARIES WITH JOINT TYPE, SHEET
ROCKAND ASSEMBLY PLANS.
STANDING SEAM
DOUBLE CORNER SEAM
GROOVED SEAM
PITTSBURGH LOCK BUTTON PUNCH SNAP LOCK
SINGLE CORNER SEAM
INSTALL AN ESCUTCHEON AROUND PIPESEXPOSED IN FINISHED ROOMS. FOR ALLINSULATED PIPING INSTALL A PLASTIC JACKETEXTENDING 6" BEYOND THE WALL TO PROTECTINSULATION FROM DAMAGE.
MAKE A SMOOTH ROUND OPENING INWALL SLIGHTLY LARGER THAN OUTSIDEDIAMETER OF THE PIPE.
ADD A BEAD OF NON-HARDENINGCAULK IN THE ANNULAR SPACE.
NOTES:
1. THIS DETAIL APPLIES TO ALL PIPES. THE INTENTION IS TO CONTINUE THEINSULATION AND VAPOR BARRIER THROUGH ALL PENETRATIONS. PERMITTHERMAL EXPANSION WITHOUT DAMAGING INSULATION, AND TO SEALAIRTIGHT AROUND INSULATED AND UNINSULATED PIPES FOR NOISETRANSMISSION CONTROL.
2. REFER TO SPECIFICATION SECTION 22 05 03 FOR ADDITIONALINFORMATION.
HEATING COIL
CONTROL VALVE
3/4" SHUTOFF VALVE WITH3/4" MALE HOSE THREADADAPTER AND CAP.
OFFSET PIPING AND LOCATEUNIONS TO ALLOW REMOVALOF COIL
MANUAL AIR VENT ATHIGH POINT OF PIPINGNEXT TO COIL. (TYP.)
UNION (TYP.)
AIR FLOW
NOTES:
1. REFER TO SPECIFICATION SECTION 23 21 00 - HYDRONICPIPING FOR BALANCE VALVE SIZING REQUIREMENTS.
HWS
HWR
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
12" = 1'-0"
MECHANICAL DETAILS
M501
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
NO SCALE1LONGITUDINAL SEAMS - RECTANGULAR DUCT
NO SCALE2PIPE THROUGH NON-FIRE RATED WALL
NO SCALE3HEATING COIL PIPING
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
16
REVISIONS
NO. DATE DESCRIPTION
T
AI
AO
H
DI
AI
AO
AIAO
AI
T
T
DI
HAI
H
THERMOSTAT
TERMINAL AIR BOX W/REHEAT COIL
TEMPERATURE SENSOR
ANALOG INPUT
ANALOG OUTPUT
CONTROL SYMBOLS LISTSYMBOL: DESCRIPTION:
ACT ACTUATOR
T
HEATING WATER RETURNHWR
HEATING WATER SUPPLYHWS
CONTROL VALVE (TWO-WAY)
HUMIDISTAT
DIGITAL INPUT
TERMINAL AIR BOX REPORT & DUCT MOUNTED HOT WATER REHEAT COIL GENERATION:DDC FMCS SHALL BE PROGRAMMED TO GENERATE THE FOLLOWING REPORT BASED ON A MANUALCOMMAND FROM THE DDC FMCS WORKSTATION BY CLICKING ON A GRAPHICAL BUTTON. UPONINITIATING COMMAND THE DDC FMCS SHALL COMPILE A REPORT AS FOLLOWS:
WHEREAS THE SAMPLE REPORT ABOVE SHOWS ONLY A COUPLE TAB/COILS, THE FINALPROGRAMMED REPORT SHALL LIST ALL TABS/COILS SERVED BY A SINGLE AHU. A SEPARATEREPORT SHALL BE PROGRAMMED FOR EACH AHU AND FOR EACH FLOOR.
AFTER THE REPORT PRINTS OUT ALL TAB/HEATING COIL DATA, THE DDC FMCS SHALLAUTOMATICALLY TOTAL ALL THE INDIVIDUAL TAB AIRFLOW TO A SINGLE VALUE.
AFTER PRINTING THE SUM OF THE TAB/HEATING COIL AIRFLOW CFM, THE DDC FMCS SHALL THENAUTOMATICALLY PRINT OUT THE AIR HANDLER REPORT FOR THE AHU WHICH SERVES THETABS/HEATING COILS LISTED IN THE REPORT.
DDC FMCS SHALL ALLOW THE DDC FMCS OPERATOR TO ISSUE A SINGLE COMMAND THAT WILLAUTOMATICALLY CHANGE THE LOCAL SETPOINT FOR EACH TAB SERVED BY A AHU TO A SINGLEVALUE (E.G. A SINGLE COMMAND WILL SET ALL TABS/HEATING COILS SERVED BY AHU-A TO 80°F). ASEPARATE TAB/HEATING COIL SETPOINT OVERRIDE COMMAND SHALL BE PROGRAMMED IN THEFMCS FOR EACH AHU.
TAB/COILSYMBOL
******
AIRFLOW(CFM)MAX/ACTUAL/MIN
***/***/******/***/***
DMPR POS(% OPEN)
85%80%
VALVE POS(% OPEN)
10%60%
SUP AIR TEMP(DEG. F)
65.275.1
ROOM TEMP(DEG. F)
73.671.1
ROOM SETPOINT(DEG. F)
72.072.0
WALL MTDTEMP SENSOR
HWS
HWR
FLOATING
PRIMARY AIR FROM ZONECONDITIONING AHU
SUPPLYAIR
ACTVELOCITY ANDSTATIC SENSOR
PRESSURE INDEPENDENTTERMINAL AIR BOX (TAB)
FAIL INPLACE
SUPPLYAIR TEMP
DAMPER ACTUATORDAMPERMOD.
TABAIRFLOW
2-WAY CONTROL VALVE
SEQUENCE OF OPERATION:
• FMCS TAB CONTROLLER SHALL MODULATE THE TAB DAMPER TO MAINTAIN CONSTANT SUPPLYAIRFLOW TO THE ROOM AS SCHEDULED.
• FMCS TAB CONTROLLER SHALL MODULATE TAB HW REHEAT COIL CONTROL VALVE TO MAINTAINSPACE TEMPERATURE OF 72°F (ADJ.) WITH 2°F (ADJ.) DEAD BAND BASED ON A SIGNAL FROM A WALLMOUNTED TEMPERATURE SENSOR. SEE DRAWINGS FOR TEMPERATURE SENSOR REQUIREMENTS.
ALARMS, INTERLOCKS & SAFETIES:
• SEND AN ALARM TO THE FMCS OPERATOR INTERFACE IF THE SPACE TEMPERATURE IS MORE THAN3°F (ADJ.) ABOVE OR BELOW SETPOINT.
GENERAL ALARM
SEQUENCE OF OPERATION:CONTROLS PROVIDED BY MFR INTEGRAL WITH UNIT.
ALARMS, INTERLOCKS & SAFETIES:SEND AND ALARM TO THE FMCS OPERATOR INTERFACE UPON THE OCCURRENCE OF ANYMICROPROCESSOR CONTROL SYSTEM ALARM CONDITIONS.
HUMIDIFIER
FACTORY MOUNTEDCONTROL PANEL
FMCS HUMIDITYMONITORING POINT.INSTALLED BY T.C.C.
NOTES:
1. HUMIDIFIER OUTPUT TO BE LIMITED TO MAINTAIN 40% RHWITHIN THE SPACE.
FACTORYPROVIDEDHUMIDISTAT
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
12" = 1'-0"
MECHANICAL SCHEDULES ANDCONTROLS
M600
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DAH
APRIL 24, 2013
BMF
1302-13-01
SCHEDULE GENERAL NOTES:A. DISCONNECT AND CONTROLLER STARTER FURNISHED AND
INSTALLED BY:
MFR = MANUFACTURER
ATC = AUTOMATIC TEMPERATURE CONTROL CONTRACTOR
B. DISCONNECT TYPE:
F = FUSED
NF = NON-FUSED
C. CONTROLLER STARTER TYPE:
FV = FULL VOLTAGE
D. FAN RPM SHALL NOT EXCEED 110% OF SCHEDULED VALUE,
WITH THE SCHEDULED WHEEL TYPE. SUBSTITUTION OF BI OR BIA
FANS FOR FC IS ACCEPTABLE IF EFFICIENCY IS NOT LOWER.
E. NO EQUIPMENT SHALL BE SELECTED ABOVE 90% OF MOTOR
NAME PLATE RATING.
F. MUST BE WITHIN +/- 10% OF SCHEDULED RPM.
G. CURB TYPE:
MFR = STANDARD CURB BY MANUFACTURER
EXHAUST FAN SCHEDULE
TAGNAME
AREASERVED CFM
S.P.IN.
W.C.
WHEELDIA.
INCHES
FANRPM
(NOTE F)DRIVETYPE
MAX.AMCASONES
BACKDRAFTDAMPER
TYPE
CURBTYPE
(NOTE G)
ELECTRICAL
MANUFACTURER MODEL REMARKSBHP MHP VOLTAGE PHASES
DISCONNECTCONTROLLER/
STARTER
BY(NOTE A)
TYPE(NOTE B)
BY(NOTE A)
TYPE(NOTE C)
EF-1 LAB SPACE 1150 0.50 13.5 1063 DIRECT 7.3 MFR MFR 0.177 0.25 120 1 MFR NF ATC FV COOK ACEB NOTE 1, 2
TERMINAL AIR BOX SCHEDULE - SINGLE DUCT
TAGNAME
AREASERVED
CFM
EAT°F
HEATING COIL(NOTES 3 & 4) MIN. INLET SIZE (IN.) CONTROL
TYPE(NOTE 3)
SENSORTYPE
(NOTE 4) MANUFACTURER MODEL NOTESCOOLING
MAX.HEATING
MAX. MIN. LAT °F EWT °FMAX.GPM DIA. WIDTH HEIGHT
TAB-327 ROOM 327 225 225 225 55.0 100.0 180 1.0 8" NA NA 1/M600 1 TITUS DESV NOTES 1, 2, 5
TAB-333 ROOM 333 160 160 160 55.0 95.0 180 0.7 8" NA NA 1/M600 1 TITUS DESV NOTES 1, 2, 5
TAB-335 ROOM 335 390 390 390 55.0 95.0 180 1.7 10" NA NA 1/M600 1 TITUS DESV NOTES 1, 2, 5
TAB-335A ROOM 335A 100 100 100 55.0 95.0 180 0.5 8" NA NA 1/M600 1 TITUS DESV NOTES 1, 2, 5
TAB-335B ROOM 335B 100 100 100 55.0 95.0 180 0.5 8" NA NA 1/M600 1 TITUS DESV NOTES 1, 2, 5
NO SCALE2TERMINAL AIR BOX REPORT GENERATION
NOTES:1. PROVIDE WITH CURB ADAPTOR TO OFFSET W/ THROAT OF NEW FAN.2. INTERLOCK FAN OPERATION WITH EXISTING AHU SERVING SPACE.
GRILLES REGISTERS & DIFFUSERS SCHEDULE
TAGNAME MATERIAL CONFIGURATION
MARGIN(NOTE 1)
INLETSIZE(IN.)
FACESIZE(IN.)
VOLUMEDAMPER
REQUIRED FINISH MANUFACTURER MODEL NOTESCD-1 STEEL LOUVER FACE LAY-IN SEE DWG. 24x24 NO WHITE TITUS TMS STAMPED LOUVER DROP FACE. MINIMUM OF TWO
STEPDOWN DIFFUSION CONES
EG-1 STEEL 35 DEGREEDEFLECTION
1 1/4" SEE DWG. INLET +2 NO WHITE TITUS 350R
NO SCALE1CONSTANT VOLUME TAB CONTROL
NOTES:1. NEITHER RADIATED NOR DISCHARGE SOUND LEVELS SHALL EXCEED NC 35 AT 1.5" INLET STATIC PRESSURE WHEN TESTED PER ARI STANDARD 885-98 USING 5/8" 20-LB DENSITY MINERAL FIBER CEILING TILE.2. TOTAL AIR PRESSURE DROP OF TAB AND REHEAT COIL SHALL NOT EXCEED 0.50" WC.3. SENSOR TYPES: 1 - SENSOR ONLY, 2 - SENSOR WITH ADJUSTMENT, 3 - SENSOR WITH OVERRIDE, 4 - SENSOR WITH ADJUSTMENT AND OVERRIDE.4. HEATING COIL IS BASED ON HEATING AIR FLOW. WATER PRESSURE DROP OF REHEAT COILS SHALL NOT EXCEED 5'. PROVIDE REHEAT COILS SEPARATE FROM BOXES IF REQUIRED TO MEET WATER PRESSURE DROP
REQUIREMENTS. WHEN LAT °F, EWT °F, AND GPM VALUES ARE BLANK, HEATING COIL IS NOT REQUIRED FOR TAB.5. BOX SHALL NOT COME WITH MANUFACTURER PROVIDED CONTROLS. BOX SHALL BE MODIFIED TO ALLOW SCHNEIDER ELECTRIC INET CONTROLLERS IN ORDER TO INTEGRATE WITH EXISTING CAMPUS BUILDING CONTROLS
SYSTEM. COORDINATE ALL REQUIREMENTS FOR FULL OPERATION WITH STEVE RICKLIFT - (630)-690-3900. CONTROLLER SHALL BE SHIPPED TO AND INSTALLED IN FACTORY.
NOTES:1. CONTRACTOR SHALL DETERMINE PROPER MARGIN STYLE TO MATCH CEILING CONSTRUCTION.2. ALL RUN OUT DUCTWORK TO DIFFUSERS SHALL BE NECK SIZE UNLESS OTHERWISE NOTED.
NO SCALE3HUMIDIFIER CONTROL
HUMIDIFIER SCHEDULE - ELECTRIC
TAGNAME
AREASERVED
CAPACITY(LBS/HR) DUCT SIZE
MANIFOLDLENGTH
NUMBEROF
CIRCUITSKW PERCIRCUIT
ELECTRICAL
MANUFACTURER MODEL NOTESKW VOLT-PHASE
DISCONNECT CONTROLLER/STARTER
BY(NOTE A)BY (NOTE A)
TYPE(NOTE B)
H-1 335A 5 NOTE 1 NOTE 1 1 1.9 1.9 120-1 MFR F MFR NORTEC NHT NOTES 1, 2, 3
H-2 335B 5 NOTE 1 NOTE 1 1 1.9 1.9 120-1 MFR F MFR NORTEC NHT NOTES 1, 2, 3
NOTES:1. PROVIDE WITH BUILT ON UNIT MOUNTED BLOWER PACK. ENTIRE UNIT SHALL HAVE SINGLE POINT POWER CONNECTION.2. PROVIDE A DRAIN LINE WITH DRAIN WATER COOLER FOR STEAM GENERATOR DISCHARGE.3. REFER TO 3/M600 FOR HUMIDIFIER CONTROLS.
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
17
REVISIONS
NO. DATE DESCRIPTION
INDICATES DETAIL NUMBER/SHEET NUMBER.
INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES. REFER TODRAWINGS CONTAINING ELECTRICAL SCHEDULES. PERMANENT NAMEPLATE SHALL MATCHFINAL EQUIPMENT NOMENCLATURE, NOT ELECTRICAL EQUIPMENT TAG NAME, REFER TOSPECIFICATIONS.
INDICATES KEYED NOTE USED TO DESCRIBE ADDITIONAL INFORMATION OF WORK REQUIRED,SPECIFIC TO THE SHEET AND/OR DETAIL IT IS SHOWN WITH.
INDICATES LUMINAIRE IS SWITCHED DURING NORMAL OPERATION AND OPERATES FROMEMERGENCY GENERATOR UPON LOSS OF POWER. CONNECT THE SWITCHING DEVICE TOTHE BALLAST FOR NORMAL OPERATION. REFER TO 4/E401 FOR ADDITIONAL INFORMATION.
SHADED LUMINAIRE OR DEVICE INDICATES LUMINAIRE OR DEVICE IS CONNECTED TO ANEMERGENCY CIRCUIT.
ALL ELECTRICAL CONDUCTORS SHALL BE COPPER.
LUMINAIRE KEY:
DEVICE KEY:
ABBREVIATION KEY:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
"1/E401"
WW-1
" "
"SE"
#
E.C.ELECTRICAL CONTRACTORG.C. GENERAL CONTRACTORC CONDUITTYP TYPICAL+##" MOUNTING HEIGHT FROM FINISHED FLOOR TO CENTERLINE
MOUNTING SUBSCRIPT KEY:
RECEPTACLES AND TELECOMMUNICATIONS OUTLETS:
A SLASH IS USED BETWEEN TWO SUBSCRIPTS ie: A/HREFER TO MATERIAL LIST AND SPECIFICATIONS FOR FULL DESCRIPTIONS AND MANUFACTURERSOF ALL DEVICES.
LINE TYPE KEY:
A MOUNT ABOVE COUNTER (+6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH)
NEW WORK BY THIS CONTRACTOR (DARK SOLID LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN (LIGHT SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR (DARK SHORT DASHED LINE)
GENERAL ELECTRICAL NOTES
LUMINAIRE
F1 = FIXTURE TAG
a = SWITCH NUMBER
SE = SUBSCRIPT (IF APPLICABLE)
*IF LABEL IS ORIENTED HORIZONTALLY A /
WILL SEPARATE THIS INFORMATION.
EX: F1 / 1 / a / SE
DEVICEA = MOUNTING (IF APPLICABLE)
1 = CIRCUIT NUMBER
*IF LABEL IS ORIENTED HORIZONTALLY A / WILL SEPARATE THIS
INFORMATION.
EX: A / 1
THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADAAG (AMERICANS WITHDISABILITIES ACT ACCESSIBILITY GUIDELINES).
CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE WITHNUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR BRANCH CIRCUITS.BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN EACH PHASE.
CIRCUITS SERVING EMERGENCY LUMINAIRES WILL BE RUN IN SEPARATE RACEWAY FROM ALL OTHERCIRCUITS.
A #12 GREEN INSULATED GROUND CONDUCTOR SHALL BE INSTALLED WITH CIRCUIT CONDUCTORS TO ALLRECEPTACLES.
CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, AND ABOVE CEILING, ETC. UNLESS OTHERWISE INDICATEDON THE PLANS OR IN THE SPECIFICATIONS.
BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM OF 6"HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE OFFSET A MINIMUM OF 24"HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE ALLOWED WITHOUT PRIOR WRITTEN APPROVALOF THE ARCHITECT/ENGINEER.
FLUSH MOUNT ALL TOGGLE SWITCHES AT +42" FROM FLOOR (CENTERLINE DIMENSION), EXCEPT WHEREOTHERWISE NOTED. TOGGLE SWITCHES MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIEDEXPOSED.
FLUSH MOUNT ALL DUPLEX RECEPTACLES AND TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR,EXCEPT WHERE OTHERWISE NOTED. RECEPTACLES AND OUTLETS MAY BE SURFACE MOUNTED WHENCONDUIT IS SPECIFIED EXPOSED.
INSTALL ALL WALL MOUNTED FIRE ALARM NOTIFICATION DEVICES AT 90" ABOVE FINISHED FLOOR OR 6"BELOW THE CEILING, WHICHEVER IS LOWER, EXCEPT WHERE OTHERWISE NOTED. HEIGHT SHALL BEMEASURED TO THE TOP OF THE DEVICE.
CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL DETECTORS WITH LUMINAIRES, AND CEILINGDIFFUSERS. CENTER ALL DEVICES IN CEILING TILE PATTERN.
CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS WITH ARCHITECTURAL PLANS, ELEVATIONS ANDREVIEWED SHOP DRAWINGS. PRIOR TO MAKING THE ACTUAL ELECTRICAL INSTALLATION THISCONTRACTOR SHALL ADJUST RECEPTACLES, OUTLETS OR CONNECTION LOCATIONS TO ACCOMMODATEFURNITURE AND/OR EQUIPMENT.
ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF,OPERATION OF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OFELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT, ON EQUIPMENT SUPPLIED BY ANOTHERCONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE OTHER CONTRACTOR.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BEREPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR.ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS.
ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL BE TESTED ANDCERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF THROUGH-PENETRATIONFIRESTOPS, SEE SECTION 26 05 03. CONTRACTOR SHALL REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE EXECUTION OFELECTRICAL WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION. CONTRACTOR SHALLREPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS CONTRACTOR.
CONDUIT SLEEVES (WHEN NOT SHOWN ON THE DRAWINGS) AND LINE VOLTAGE POWER (WHEN NOTSHOWN BUT REQUIRED FOR PROPER INSTALLATION OF SYSTEM) ARE BASED ON THE INHERENTDIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURER, ALL REQUIRED EQUIPMENT MAY NOT BESHOWN ON THE DRAWINGS OR ON CONTRACT DRAWINGS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
ELECTRICAL INSTALLATION NOTES
THE ELECTRICAL DRAWINGS INDICATE EXISTING ELECTRICAL ITEMS TO BE REMOVED. THE DRAWINGSARE INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT INDICATE EVERY BOX,CONDUIT, OR WIRE THAT MUST BE REMOVED. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TOSUBMITTING A BID AND VERIFY EXISTING CONDITIONS.
ELECTRICAL ITEMS (i.e., LIGHTING FIXTURES, RECEPTACLES, SWITCHES, ETC.) REMOVED AND NOTRELOCATED REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FORTHE DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TO REUSE OR RETAIN (i.e., FOR MAINTENANCEPURPOSES).
THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF POWER TOCIRCUITS, FEEDERS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER. CONDUIT CONCEALED INWALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT AFFECTED BY OTHER CONSTRUCTION.
WHERE LIGHTS, SWITCHES, RECEPTACLES, EQUIPMENT CONNECTIONS, ETC., ARE BEING REMOVED ALLASSOCIATED CONDUIT AND WIRE BACK TO THE PANELBOARD OR FEEDER JUNCTION BOX SERVING THEDEVICE SHALL ALSO BE REMOVED, UNLESS NOTED OTHERWISE.
ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE CONDUIT IS IN THECONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG. WHERE CONDUIT IS RUN EXPOSED, ALLASSOCIATED CLAMPS, SUPPORTS, HANGERS, ETC., SHALL ALSO BE REMOVED.
THIS CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER CONTRACTORS AT THE JOB SITEBEFORE REMOVING EXISTING ELECTRICAL AND INSTALLING NEW ITEMS.
EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATED EXISTING CONDUITSHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE INSTALLED IN ALL REUSED CONDUIT TOASSURE PROPER GROUND PATH.
EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A JUNCTION BOX TORECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND CONDUIT AND WIRING AS REQUIRED TOMAINTAIN POWER TO REMAINING EQUIPMENT.
CONTRACTOR SHALL REMOVE AND INSTALL ALL CEILING TILES AS REQUIRED FOR THE EXECUTION OFELECTRICAL WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION. CONTRACTOR SHALLREPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS CONTRACTOR.
BALLASTS MANUFACTURED PRIOR TO 1980 CONTAIN PCBs AND SHALL BE DISPOSED OF BY A FEDERAL ORSTATE E.P.A. APPROVED METHOD AND IN ACCORDANCE WITH SPECIFICATIONS.
HID AND FLUORESCENT LAMPS CONTAIN MERCURY AND SHALL BE DISPOSED OF BY A FEDERAL OR STATEE.P.A. APPROVED METHOD AND IN ACCORDANCE WITH SPECIFICATIONS.
REFER TO SPECIFICATION SECTIONS 26 05 05 AND 27 05 05 FOR ADDITIONAL INFORMATION.
1.
2.
3.
4.
5.
6.
7.
8.
9
10.
11.
12.
ELECTRICAL DEMOLITION NOTES
1'X4' LUMINAIRE
DOWNLIGHT
ELECTRICAL DEMOLITION SYMBOL LIST
SYMBOL: DESCRIPTION:
DUPLEX RECEPTACLE
GROUND FAULT DUPLEX RECEPTACLE
SIMPLEX RECEPTACLE
QUAD RECEPTACLE
TIME CLOCK
FIRE ALARM - HEAT DETECTOR
TC
H
DATA INFORMATION OUTLET
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
12" = 1'-0"
ELECTRICAL COVER SHEET
E000
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DEK
APRIL 24, 2013
JML
1302-13-01
18
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
REVISIONS
NO. DATE DESCRIPTION
TC
TC
TC
OC
OC
TC
TC
H
H
TC
H
E
3 4 5 6
7
A
B
ANIMALHOUSING 2
335 B
ANIMALHOUSING 1
335 A
PROCEDURELAB
335
PSYCHMARINE
HOUSING
333
8
CORRIDOR
383
PSYCHMARINE
DIAGONISTICLAB
327
F1E/SE
F1A
F1BF1A/a F1A/a
F1A/a
F1E/a/SE
F1B
F1A/b
F1E/b/SE
F1A/a
3 3/a /b
33
/a/b
D1
F2F2
T
T
D
1
F3/b
T
2
2
2
3
3
3
EXISTING PANEL 'LPL 3-33 SEC.1'
EXISTING PANEL 'LPL 3-33 SEC.2'
a b
F2
F2
F2
F2
F2
F2
3 4 5 6
7
A
B
BIO ANIMALLABS
335
PSYCHMARINE LAB
333
8
PSYCHMARINE LAB
327
CORRIDOR
383
GREENHOUSE
345
EXISTING PANEL 'LPL 3-33 SEC.1'
TO REMAIN
EXISTING PANEL 'LPL 3-33 SEC.2'
TO REMAIN
5
EXISTING IT CLOSET 339
2 3
E
F
G
H
J
EXISTINGHUMIDIFIER TOBE REMOVED
5
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
As indicated
THIRD FLOOR PLAN - ELECTRICAL -DEMOLITION & LIGHTING
E101
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DEK
APRIL 24, 2013
JML
1302-13-01
NO R HT
1/4" = 1'-0"2THIRD FLOOR PLAN - ELECTRICAL - LIGHTING
NO R HT
1/4" = 1'-0"1THIRD FLOOR PLAN - ELECTRICAL - DEMOLITION
GENERAL SHEET NOTES :
1. REFER TO SHEET E000 FOR ELECTRICALDEMOLITION NOTES, ELECTRICAL DEMOLITIONSYMBOL LIST, GENERAL ELECTRICAL NOTES,AND ELECTRICAL INSTALLATION NOTES.
2. REFER TO SHEET E400 FOR GENERALELECTRICAL EQUIPMENT SCHEDULE,LUMINAIRE SCHEDULE, AND PANEL SCHEDULE.
3. EXTEND EXISTING LIGHTING CIRCUIT IN EACHROOM UTILIZING 2#12 & 1#12 GND IN 3/4" C. FORCONNECTION TO NEW LUMINAIRES.
4. HATCHED AREAS DENOTE AREAS WITH NOSCOPE OF WORK..
5. EXISTING BACKBOXES AND CONDUIT THAT AREEMBEDDED IN BLOCK WALL SHALL BEABANDONED IN PLACE. PROVIDE A BLANKCOVERPLATE FOR OPEN BACKBOXES.
6. ALL TECHNOLOGY INFORMATION OUTLETS ARESERVED FROM EXISTING IT CLOSET 339.
KEYNOTES:
1. REFER TO 2/E401 FOR OCCUPANCY SENSORWIRING DIAGRAM.
2. LUMINAIRES IN THIS ROOM SHALL BECONTROLLED VIA TIME CLOCK. REFER TO3/E401 FOR TIME CLOCK WIRING DIAGRAM.
3. EXTEND A PORTION OF EXISTING EMERGENCYLIGHTING CIRCUIT FROM NIGHT LIGHT INCORRIDOR 320 TO CONNECT TO SWITCHEDEMERGENCY FIXTURE UTILIZING 2#12 & 1#12GND IN 3/4" C. REFER TO 4/E401 FOREMERGENCY TRANSFER DEVICE WIRINGDIAGRAM.
4. REMOVE 30A-3P BREAKERS IN EXISTING PANELTO MAKE SPACE FOR NEW CIRCUITS.
5. COORDINATE WITH CONTRACTOR REMOVINGEQUIPMENT. FOR EXACT LOCATION OFEQUIPMENT.
#
NO R HT
1/16" = 1'-0"3PENTHOUSE - ELECTRICAL - DEMOLITION
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
19
REVISIONS
NO. DATE DESCRIPTION
H
FIRE ALARM DEVICE SCHEDULE
A1 A3
A7 AH
ITEM
NO.SYMBOL DESCRIPTION APPROVED MANUFACTURERS
THE SCHEDULE LISTED BELOW IS FOR FIRE ALARM DEVICE QUICK REFERENCE ONLY. REFER TO GENERAL ELECTRICAL EQUIPMENT SCHEDULE ON E400FOR COMPLETE LIST OF EQUIPMENT.
2
HEAT DETECTOR, COMBINATION RATE OF RISE AND 135 DEGREE FAHRENHEIT FIXEDTEMPERATURE, 2-WIRE OPERATION, 2-PIECE DESIGN, LOW-PROFILE DESIGN, COMPLETE WITHMOUNTING HARDWARE AND BACKBOX.
1 GAMEWELLMATCH EXISTING
GAMEWELLMATCH EXISTING
FIRE ALARM AUDIO/VISUAL NOTIFICATION APPLIANCE, ELECTRONIC HORN WITH SELECTABLE
OR TEMPORAL TONE, SELECTABLE SOUND OUTPUT AND HIGH-INTENSITY STROBE, RED
HOUSING WITH WHITE LETTERING OR PICTOGRAM, SEMI-FLUSH WALL MOUNT; 24 VDC.
CANDELA RATINGS: A1=15, A3=30, A7=75, AND AH=110. CANDELA RATING SHALL BE VISIBLE
FROM THE OUTSIDE OF THE DEVICE.
C4
C4
C4
C4
C4
C4
C4
C4
C4
C4
C4
C4
E
E
E
C4
H
H
H
H
A1 A1A1
H
3 4 5 6
7
A
B
ANIMALHOUSING 2
335 B
ANIMALHOUSING 1
335 A
PROCEDURELAB
335
PSYCHMARINE
HOUSING
333
8
CORRIDOR
383
PSYCHMARINE
DIAGONISTICLAB
327
BEDDING STATION+36"+60"
WW-1WW-1
WW-1 WW-1
+56"+56"
REFRIGERATOR
1515
17
5
18
18
18
18
5
18
25
19
55
22
26
H-1
26
26
27 28 27
27
4
ST-2
2729
2629
H-2
29
6
6
6
6
6
EXISTING IT CLOSET 339
EXISTING PANEL 'LPL 3-33 SEC.1'
EXISTING PANEL 'LPL 3-33 SEC.2'
6
16
16
WW-1
15
15
16
16
16
16
6
17
17
17
25
25
25
25
25
24
24
24
24
24
24
23
23
23
23 22
22
22
21
21
21
21
21
21
20
20
20
20
20
20
7
26
26
30
31
7
5
8
3
3
3
+18"
6
3 4 5 6
7
A
B
ANIMALHOUSING 2
335 B
ANIMALHOUSING 1
335 A
PROCEDURELAB
335
PSYCHMARINE
HOUSING
333
8
CORRIDOR
383
PSYCHMARINE
DIAGONISTICLAB
327
1
2
1
2
1
12
1
EXISTING PANEL 'LPL 3-33 SEC.1'
EXISTING PANEL 'LPL 3-33 SEC.2'
4 4 4
A= MOUNTING (IF APPLICABLE)1= CIRCUIT NUMBER
*IF LABEL IS ORIENTED HORIZANTALLY A'/' WILL SEPARATE THISINFORMATIONEX:A/1
DEVICE
DEVICE KEY
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
As indicated
THIRD FLOOR PLAN - ELECTRICAL -POWER, TECHNOLOGY & SYSTEMS
E201
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DEK
APRIL 24, 2013
JML
1302-13-01
NO R HT
1/4" = 1'-0"1THIRD FLOOR PLAN - ELECTRICAL - POWER & TECHNOLOGY
NO R HT
1/4" = 1'-0"2THIRD FLOOR PLAN - ELECTRICAL - SYSTEMS
GENERAL SHEET NOTES :
1. REFER TO SHEET E000 FOR GENERALELECTRICAL NOTES AND ELECTRICALINSTALLATION NOTES.
2. REFER TO SHEET E400 FOR GENERALELECTRICAL EQUIPMENT SCHEDULE, PANELSCHEDULE AND INFORMATION OUTLETSCHEDULE.
3. ALL INFORMATION OUTLETS SHALL BE SERVEDFROM EXISTING EQUIPMENT RACK IN EXISTING ITCLOSET 339. COORDINATE LOCATION OF NEWPATCH PANELS ON EXISTING EQUIPMENT RACK.
4. REFER TO 1/E400 FOR CONNECTIVITY RISERDIAGRAM.
5. HATCHED AREAS DENOTE AREAS WITH NOSCOPE OF WORK.
6. REFER TO E301 FOR LOCATION OF EXISTING FIREALARM CONTROL PANEL.
7. ALL NEW POWER CIRCUITS SHALL BE FED FROMEXISTING PANEL 'LPL 3-33 SEC.1'.
KEYNOTES:
1. EXTEND A PORTION OF EXISTING FIRE ALARMINITIATING CIRCUIT TO CONNECT TO HEATDETECTOR.
2. CONNECT DEVICE TO NEW NOTIFICATIONAPPLIANCE CIRCUIT FROM CLOSEST NACEXTENDER PANEL OR CONTROL PANEL, ORCONNECT TO EXISTING NOTIFICATIONAPPLIANCE CIRCUIT OR PROVIDE NEW NACEXTENDER PANEL PER SPECIFICATIONS.
3. COORDINATE WITH INSTALLING CONTRACTORFOR EXACT EQUIPMENT LOCATION.
4. INSTALL DEVICE AND WIRING TO ABOVECEILING IN SURFACE RACEWAY (WIREMOLDV700 OR APPROVED EQUAL).
5. ROUTE SURFACE RACEWAY TO CEILING.REFER TO 1/E401 FOR ADDITIONALINFORMATION.
6. INSTALL OUTLETS IN WIREWAY WW-1.
7. DISCONNECT PROVIDED BY MANUFACTURER,WIRED BY ELECTRICAL CONTRACTOR.
8. NEW CIRCUIT BREAKERS IN EXISTING PANELSHALL MATCH EXISTING RATINGS ANDCONSTRUCTION.
#
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
20
REVISIONS
NO. DATE DESCRIPTION
35 NA
260 NA
160 NA
120 NA 35 NA
5 SF
785 NA
630 SF
735 NA
530 NA
355 NA
5 S.F.
55 NA
365 NA
265 SF
810 NA
1105 SF
475 NA
825 SF20 NA
1925 NA
1995 SF
140 SF
80 NA
35 SF
35 SF
265 SF
10 NA
1435 SF
140 NA
1560 NA 35 NA
210 NA
120 S.F.
635 SF
690 NA
160 NA
630 NA
975 SF
125 NA
15 NA
285 SF
55 SF
210 NA
35 NA
5 SF
15 SF
125 NA
135 NA
1925 NA
25 NA
225 NA
140 NA
70 NA
10 NA
80 NA
140 NA
195 NA
110 NA 110 NA
990 SF
5 SF
135 NA
5 NA
55 NA
320 NA
10 SF
130 NA
955 NA
540 NA
955 NA
405 SF
10 SF
265 SF
25 NA
20 NA
970 NA
1315 SF
480 NA
955 NA
450 NA
115 NA
110 NA
185 NA
199 NA
185 NA
255 NA 210 NA
265 SF
885 SF
115 NA
110 NA
470 NA
460 NA
20 NA
275 NA
155 NA
360 NA
75 SF
75 SF
354 SF
250 NA
85 SF
10
K
H
J
H
G
F
E
D
C
A
B
1 2 3 4 5 6 7 8 8' 9 9' 11 12 13 14 15 16 17
X
W
V
U
T
S
18 19 20
R
P
N
M
VESTIBULE
VESTIBULE
VESTIBULE
DISPLAY
RADIOACTIVE LAB
WET. PREP.
STAIR
LOCKERS
MECH.
CLASSROOM
CORR
CHEMISTRY LAB
CLASSROOM
PREP.
BIOLOGY LAB
STAIR
CLASSROOM
ELECTRICAL
CLASSROOM
CORRIDORLOCKERS
LECTURE
MECHANICAL
JANITOR
VESTIBULE
VESTIBULE
PROJ.
STAIR
DISPLAY
LOBBY
OPEN TO
BASEMENT
BELOW
AV. STOR.
OPEN
OPEN
CORRIDOR
VOLATILE
STORAGE
STORAGE
CORRIDOR
CLASSROOM
A.V. CONNECT'N
STUDIO LAB
CORRIDOR
B & G STORAGE
STORAGE
LOCKERS
RECEIVING
ELEV 5
JAN.
MECH.
OPEN
LOCKERS
STORAGE
OFFICE
LECTURE
DISPLAY
OFFICE
OFFICE
WKRM.
DISPLAY
PROJ.
A.V. STORAGE
OFFICE
OFF. OFF.
CORRIDOR
DISPLAY
OFFICE
DISPLAY
VESTIBULE
PREP.
MECH.
OFFICE
ANTHROPOLOGY LAB
PREP.
EARTH SCI. LABCLASSROOM
WOMEN
MECH.
STAIR
LOCKERS
DISPLAY
DRAFTING ROOM
CORRIDOR
EARTH SCI. LAB
LAB
OFFICE
OFFICE
OFFICE
OFFICE
LAB ANTHRO
OFFICE
STAIR
CORRIDOR
OFFICE
OFFICE
CLAASROOM
CLASSROOM
DISPLAY
ROCK ROOM
DARKROOM
X-RAY LAB
ELEV 24
MECHANICAL
ELEVATOR NEW VESTIBULE
ANTHRO
OFFICE
STORAGE
ROOM
MECHANICAL
ELEVATOR 5
181A
SEE SHEET-25
FOR LOWER LEVEL
PLAN
115
117
195
181C
113
183
121
123
105
181D
101C
125
191
129
127
137
181B181
111
101
109
101B
103
101 A
100D
193
100
107
100A102B
102A
143
131A
185
131
133
135
139
187 A
119
187
199
141
162C
162A
141A
187 B
158 C
100C
158A
104
158B
100B
106
108
158
102
152 150
186
186A
154
186 B
102C
110
110A
148A
156
132
112
162
162B
192
182 C
182 A
116
182
114
120
118
146
148
144
134 134A
194
142
184
140
138
130
124
182 B
122
128
136
126
196A 100G
144A
198
196
EXISTING FIREALARM CONTROLPANEL
EXISTING FIRE ALARMANNUNCIATOR PANEL
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
N
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
BERNARD J. BROMMEL HALL(PROJECT BUILDING)
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
1/16" = 1'-0"
FIRST FLOOR PLAN - ELECTRICAL -EXISTING SYSTEMS
E301
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DEK
APRIL 24, 2013
JML
1302-13-01
NO R HT
1/16" = 1'-0"1FIRST FLOOR PLAN - ELECTRICAL - EXISTING SYSTEMS
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
21
REVISIONS
NO. DATE DESCRIPTION
H
PAIR 3
PAIR 4PAIR 1PAIR 2
BR
8WBR
7G
6WBL
5BL
4WG
3O
21WO
S
C#
NO SCALE
EXISTING PANEL NAME: LPL 3-33 SEC. 1 NEW CONNECTED 20.7 KVA
MAIN: 225A/3P CB
MOUNTING: RECESSED SOLID NEUTRAL VOLTS: 208Y / 120
GROUND BUS PHASE: 3
WIRE: 4
K K
E NOTES: UNLESS NOTED OTHERWISE, ALL CIRCUITS SHALL HAVE 2#12 & 1#12 GND IN 3/4" C. USE #10 FOR CIRCUIT HOME RUN LENGTH OVER 75'. E
Y CKT LOAD BREAKER BREAKER LOAD CKT Y
* NO. LOAD DESCRIPTION KVA AMP P AMP P KVA LOAD DESCRIPTION NO. *
1 EXISTING LOAD -- 20 1 20 1 -- EXISTING LOAD 2
3 EXISTING LOAD -- 20 1 20 1 -- EXISTING LOAD 4
5 EXISTING LOAD -- 20 1 20 1 -- EXISTING LOAD 6
7 EXISTING LOAD -- 20 1 20 1 -- EXISTING LOAD 8
9 EXISTING LOAD -- 20 1 20 1 -- EXISTING LOAD 10
11 EXISTING LOAD -- 20 1 20 1 -- EXISTING LOAD 12
13 EXISTING LOAD -- 20 1 20 1 -- EXISTING LOAD 14
N 15 POWER 1.2 20 1 20 1 1.2 POWER 16 N
N 17 POWER 0.8 20 1 20 1 1.2 POWER 18 N
N 19 POWER 1.6 20 1 20 1 1.2 POWER 20 N
N 21 POWER 1.2 20 1 20 1 0.8 POWER 22 N
N 23 POWER 0.8 20 1 20 1 1.2 POWER 24 N
N 25 POWER 1.2 20 1 20 1 1.2 POWER 26 N
N 27 POWER, ST-2 1.1 20 1 20 1 1.0 POWER 28 N
N 29 POWER 1.2 20 1 20 1 1.9 H-1 30 N
N 31 H-2 1.9 20 1 20 1 SPARE 32 N
N 33 SPARE 20 1 20 1 SPARE 34 N
35 SPACE SPACE 36
KEY: *N=NEW CIRCUIT BREAKER
LUMINAIRE SCHEDULE(MTG) MOUNTING: (Type) LAMP TECHNOLOGY: (L/L) LENS/LOUVER:
RE - RECESSED FL - FLUORESCENT A- .125" ACRYLIC
SP - SUSPENDED CF - COMPACT FLUORESCENT B- BLACK BAFFLE
CL - CEILING SURFACE HL - HALOGEN C- CLEAR ALZAK
WL - WALL IN - INCANDESCENT D- PARABOLIC
UC - UNDER CABINET LED - LIGHT EMITTING DIODE F- FRESNEL
CV - COVE HS - HIGH PRESSURE SODIUM G- TEMPERED GLASS
PL - POLE MH - METAL HALIDE H- WALL WASHER
FR- FLANGED RECESSED SMH - SUPER METAL HALIDE P- POLY CARBONATE
O - OTHER ( SEE DESCRIPTION) PSMH - PULSE START METAL HALIDE K- KSH12 .125" ACRYLIC
DOOR: CMH - CERAMIC METAL HALIDE K19- KSH19 .156" ACRYLIC
FA - FLAT ALUMINUM O - OTHER (SEE DESCRIPTION) L- LOW IRIDESCENT SPECULAR ALUM.
FS - FLAT STEEL XL - EXTENDED LIFE N- NONE
RA - REGRESSED ALUMINUM XLP - EXTENDED LIFE & OUTPUT R- HIGH IMPACT DR ACRYLIC
RS - REGRESSED STEEL O- OTHER (SEE DESCRIPTION)
(TYPE) BALLAST: (TYPE) BALLAST:
FINISH: DIM07- LINE DIMMING BALLAST EB- ELECTRONIC BALLAST
PAF - PAINT AFTER FABRICATION DIM10- 0-10V DIMMING BALLAST EM- EMERGENCY BATTERY/BALLAST
CSA - FINISH SELECTION BY ARCHITECT HL- HIGH / LOW LEVEL BALLAST DALI- DIGITAL DIMMING BALLAST
ML- MULTI-LEVEL SWITCHING MV- MULTI-VOLTAGE ELECTRONIC 120V-277V
HP- HIGH PERFORMANCE / LBF #BF- BALLAST FACTOR
CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE
DESCRIPTION AND THE SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE
FIRST MANUFACTURER LISTED IS THE BASIS FOR DESIGN.
REFER TO SPECIFICATION SECTION LIGHTING 26 51 00 FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
ALL LAMPS FOR THIS PROJECT SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED.FLUORESCENT LAMP CORRELATED COLOR TEMPERATURE 4100°K, COLOR RENDERING INDEX (CRI) AT OR ABOVE 80, UNLESS NOTED OTHERWISE.
ITEM DESCRIPTION
DIMENSIONS LAMPS BALLAST
L/LL W H DIA MTG TYPE QTY MODEL VOLTS TYPE
APPROVEDMANUFACTURER
F1A RECESSED VOLUMETRIC LUMINAIRE,
CENTER DIFFUSER, 20 GA. STEEL
HOUSING, BOTTOM ACCESS TO BALLAST
COMPARTMENT, FROSTED WHITE
ACRYLIC DIFFUSERS, POLYESTER
POWDER COAT.
48" 24" 4.5" RE FL 2 28 WATT
F28T8
120 V EB O LEDALITE 3324-D1LINEARAXISFINELITEPINNACLELIGHTOLIER
F1B SIMILAR TO F1A, PROVIDE LAMPS WITH
5000°K CORRELATED COLOR
TEMPERATURE.
48" 24" 4.5" RE FL 2 28 WATT
F28T8
120 V EB O REFER TO F1A
F1E SIMILAR TO F1A, PROVIDE WITH BODINE
OR EQUIVALENT GENERATOR TRANSFER
DEVICE.
48" 24" 4.5" RE FL 2 28 WATT
F28T8
120 V EB O REFER TO F1A
F2 UNDER CABINET LUMINAIRE, LOW
PROFILE, SOLID FRONT ALLOWING
DOWNLIGHTING ONLY, DIE-FORMED
COLD ROLLED STEEL HOUSING,
REFLECTIVE WHITE POLYESTER POWDER
COAT FINISH. PROVIDE WITH ITEGRATED
ROCKER SWITCH.
24" 5.5" 1.75" UC FL 1 17 WATT
F17T8
120 V EB A H.E. WILLIAMS 2SF-24-1-17LIGHTOLIERAMERICAN FLUORESCENTMETALUX
F3 RECESSED DOWNLIGHT LUMINAIRE,
GALVANIZED STAMPED STEEL
MOUNTING FRAME AND BRACKETS,
1500 LUMEN OUTPUT, 4000K
CORRELATED COLOR TEMPERATURE,
WIDE BEAM SPREAD, WHITE PAINTED
FLANGE.
7.25" 6" RE LED 1 27 WATT 120 V LC LIGHTOLIER C6L1520-DL-40K-W-CL-WINDYPORTFOLIO
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FORCLARIFICATION OF CONNECTION LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREASHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING AND QUANTITY INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONALINFORMATION.
KEYNOTES:
1. 23 GAUGE, 4-PAIR, CATEGORY 6A, UNSHIELDED TWISTED PAIR CABLE, SEE SPECIFICATIONS.
2. SEE INFORMATION OUTLET SCHEDULE FOR QUANTITY OF CABLES AND JACKS TO BE INSTALLED AT EACH INFORMATION OUTLET.
3. RJ-45 TO RJ-45 CATEGORY CAT 6A UTP PATCH CORD TO BE PROVIDED BY OWNER.
4. PROVIDE NEW PATCH PANEL FOR EACH JACK COLOR (BLUE, YELLOW, WHITE AND GRAY). COORDINATE LOCATION ON EXISTING EQUIPMENTRACK WITH OWNER PRIOR TO INSTALLATION.
OWNER
PROVIDED
EQUIPMENT
SC-MPP-1
ANSI/TIA/EIA T568BPIN/PAIR ASSIGNMENT
IDENTIFICATION
IDENTIFICATION
2-PORT FACEPLATE
IDENTIFICATION
IDENTIFICATION
2-PORT FACEPLATE
IDENTIFICATION
IDENTIFICATION
2-PORT FACEPLATE
GENERAL ELECTRICAL EQUIPMENT SCHEDULE
1CONNECTIVITY RISER DIAGRAM
C#
OCD
S
S3
T
A1 A3A1 A3
A7A7 AHAH
HUBBELLLEVITONPASS & SEYMOURCOOPER
ALL SWITCH, RECEPTACLE, OUTLET, AND COVERPLATE COLORS SHALL BE VERIFIED WITHARCHITECT, UNLESS INDICATED OTHERWISE.
1 DEVICECOLOR
HUBBELLLEVITONPASS & SEYMOURCOOPER
ALL SWITCHES, RECEPTACLES, AND OUTLETS SHALL BE COMPLETE WITH UNBREAKABLETHERMOPLASTIC COVERPLATES IN FINISHED SPACES WHERE WALLS ARE FINISHED; #302STAINLESS STEEL COVERPLATES IN UNFINISHED SPACES FOR FLUSH BOXES; ANDGALVANIZED STEEL COVERPLATES IN UNFINISHED SPACES FOR SURFACE MOUNTED BOXES.WHERE SEVERAL DEVICES ARE GANGED TOGETHER, THE COVER PLATE SHALL BE OF THEGANGED STYLE FOR THE NUMBER OF DEVICES USED. INSTALL NAMEPLATE IDENTIFICATIONPER SPECIFICATIONS.
2 COVERPLATES
HUBBELL HBL1221 LEVITON1221-2 PASS & SEYMOURPS20AC1 COOPER 2221
SWITCH, SINGLE POLE, SINGLE THROW, 120 VOLT, 20 AMP. TOGGLE HANDLE, MAINTAINEDCONTACT, SIDE AND BACK WIRED,
3
ITEM
NO.SYMBOL DESCRIPTION APPROVED MANUFACTURERS
THE SYMBOLS AND THE EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING
SYSTEM.
CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO
MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE
DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS. THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN. "STANDARD
COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE.
8 RECEPTACLE, DUPLEX, 125 VOLT, 20 AMP,3 WIRE GROUNDING TYPE, N.E.M.A.
5-20R, IMPACT RESISTANT THERMOPLASTIC FACE, STEEL BACK STRAP.
DOUBLE DUPLEX, CONSIST OF TWO DUPLEX RECEPTACLES, DOUBLE GANG BOX,
PLASTER RING AND FACEPLATE.
HUBBELL 5352A
LEVITON
PASS & SEYMOUR
COOPER
12
PARAGON EC71STTORK DWZ100AINTERMATIC ET70115C
TIME SWITCH, 7 DAY ASTRONOMIC, 1 CHANNEL, ELECTRONIC, ONE SPDT 5 AMP CONTACTS,L.C.D. DISPLAY, 12 OR 24 HOUR FORMAT, MINIMUM 100 HOURS CARRY-OVER, U.L. LISTED.
6 TC
9 HUBBELL GF20LLEVITON 7899PASS & SEYMOUR 2095COOPER VGF20
RECEPTACLE, GROUND FAULT DUPLEX, 125 VOLT, 20 AMP, 3 WIRE GROUNDING TYPE, N.E.M.A.
5-20R. TEST AND RESET BUTTONS IN IMPACT RESISTANT THERMOPLASTIC FACE.
DOUBLE DUPLEX, CONSIST OF TWO DUPLEX RECEPTACLES, DOUBLE GANG BOX, PLASTER
RING AND FACEPLATE.
WIREMOLD G4000/G4048
MONO-SYSTEMS INC.
SMS4200
HUBBELL HBL4750 SERIES
SURFACE METAL RACEWAY, METALLIC COVER, MINIMUM 2" OPENING,POWER/COMMUNICATION DIVIDER, MINIMUM 7.5 SQ. IN. CAPACITY, RECEPTACLES ANDOUTLETS SHOWN ON RACEWAY ON DRAWINGS SHALL BE MOUNTED, WITH OVERLAPPINGFACEPLATES, IN THE RACEWAY AND SHALL NOT BE MOUNTED IN BOXES ULESS SPECIFICALLYNOTED OTHERWISE.
10 WW-1
HEAT DETECTOR, COMBINATION RATE OF RISE AND 135 DEGREE FAHRENHEIT FIXEDTEMPERATURE, 2-WIRE OPERATION, 2-PIECE DESIGN, LOW-PROFILE DESIGN, COMPLETE WITHMOUNTING HARDWARE AND BACKBOX.
11 GAMEWELL
GAMEWELL MATCHMATCH EXISTING
HUBBELL HBL1223
LEVITON 1223-2
PASS & SEYMOUR
PS20AC3
COOPER 2223
SWITCH, THREE WAY, 120 VOLT 20 AMP. TOGGLE HANDLE, SIDE AND BACK WIRED.4
COVERPLATE:
PANDUIT
UICFP4WH
SYSTIMAX
BELDEN
JACK:
PANDUIT
CJ6X88TGXX
WITHIN 106 FRAME
SYSTIMAX
BELDEN
INFORMATION OUTLET, WALL MOUNT, 2, 4-PORT COVERPLATE AS INDICATED ON DRAWINGS,
SEE INFORMATION OUTLET SCHEDULE ON E400.
" # " INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE
PLANS. SEE INFORMATION OUTLET DETAIL ON E400.
INSTALL INFORMATION OUTLET IN SURFACE RACEWAY WHERE INDICATED ON DRAWINGS OR
INSTALL 4"-11/16" SQUARE BACK BOX AND 1-1/4" EMT CONDUIT TO EXISTING IT CLOSET 339.
PROVIDE REMOVABLE BLANK INSERTS FOR UNUSED PORTS (PANDUIT CMB OR APPROVED
EQUAL).
USE WIREMOLD G4048B OR EQUIVALENT WHEN INSTALLING DATA JACKS WITHIN SURFACE
RACEWAY WITH 106 STYLE INPUT FRAME FOR EVERY TWO DATA PORTS.
JACK COLOR OR INSERT SHALL BE THE SAME AS THE CABLING JACKET COLOR.
13
SEE SPECIFICATIONS FORIDENTIFICATION REQUIREMENTS(TYP.)
INFORMATION OUTLET SCHEDULE
FACEPLATE FEATURES SCHEDULE NOTES
FA
CE
PLA
TE
PO
RT
S
CONFIGURATION
DATA1 DATA2 . .4
PO
SIT
ION
1
PO
SIT
ION
2
PO
SIT
ION
3
PO
SIT
ION
4
PO
SIT
ION
5
PO
SIT
ION
6
GENERAL NOTES:
JACK LEGEND
DATA1 = CAT 6A RJ-45 (BLUE)
C4
NUMBER INDICATESFACEPLATE POSITION(TYP.)
1. PROVIDE REMOVABLE BLANK INSERT FOR UNUSED PORTS (PANDUIT CMB OR APPROVED EQUAL).
2. SEE SPECIFICATIONS FOR LABELING REQUIREMENTS.
3. SEE FLOOR PLANS FOR DEVICE QUANTITIES AND LOCATION.
4. JACKS SHALL BE CONFIGURED PER ANSI/TIA/EIA T568B REQUIREMENTS.
WATT STOPPER
DT 300 SERIES
SENSOR SWITCH
WV-PDT
HUBBELL INC.
OMNI-DT2000 OR
ATD2000C
LEVITON OSC##-MOW
WATT STOPPER TS-400HUBBELL AUTOMATION TD200
SWITCH, LOCAL TIMER, USER ADJUSTABLE TIME-OUT, 120/277 VOLT, 800/1200 WATT RATING.NO MINIMUM LOAD REQUIREMENT, FLASHES LIGHTS 1 MINUTE BEFORE TIME OUT.
5
VOICE1VOICE2
1 2
3 4
EXISTING IT CLOSET339
PANDUIT
CAT 6A:
DPA486X88TGY
JACK:
PANDUIT
CJ6X88TGXX
SYSTIMAX
BELDEN
MODULAR UNLOADED ANGULAR PATCH PANEL, 48 MODULAR RJ-45 TERMINATIONS, MOUNTS
DIRECTLY TO EIA/TIA STANDARD 19" RELAY RACK, PORT IDENTIFICATION NUMBERS,
PROVIDED WITH COLOR CODING AND LABEL HOLDER KITS, U.L. LISTED. REQUIRES (2) 1.75"
MOUNTING SPACES.
JACK COLOR OR INSERT SHALL BE THE SAME AS THE CABLING JACKET COLOR.
14 SC-MPP-1
1
DATA2 = CAT 6A RJ-45 (YELLOW)
VOICE1 = CAT 6A RJ-45 (WHITE)
VOICE2 = CAT 6A RJ-45 (GRAY)
2
(TYP. OF 2 WITHINSURFACE RACEWAY)
(TYP. OF 4)
3 1
2
4
#
7
FIRE ALARM AUDIO/VISUAL NOTIFICATION APPLIANCE, ELECTRONIC HORN WITH SELECTABLE
OR TEMPORAL TONE, SELECTABLE SOUND OUTPUT AND HIGH-INTENSITY STROBE, RED
HOUSING WITH WHITE LETTERING OR PICTOGRAM, SEMI-FLUSH WALL MOUNT; 24 VDC.
CANDELA RATINGS: A1=15, A3=30, A7=75, AND AH=110. CANDELA RATING SHALL BE VISIBLE
FROM THE OUTSIDE OF THE DEVICE.
OCCUPANCY SENSOR, CEILING MOUNTED 360 DEGREE, DUAL TECHNOLOGY PASSIVE ORPASSIVE INFARED/ INFRARED/ULTRASONIC FREQUENCY GREATER THAN 40 KHz , DUALSENSING VERIFICATIONS (REQUIRES BOTH TECHNOLOGIES TO ACTIVATE), ACOUSTICEITHER TECHNOLOGY MAINTAINS ON STATUS. ADJUSTABLE SENSITIVITY AND TIME DELAY, 5YEAR WARRANTY. SENSOR SHALL CONTROL ALL CIRCUITS IN AREA, UNLESS NOTEDOTHERWISE. INITIAL SETTINGS: TIME DELAY 10 MINUTES. CONTRACTOR SHALL SUBMITMANUFACTURER SUPPLIED SENSOR COVERAGE DRAWING FOR SHOP DRAWING REVIEW.
3
4
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
12" = 1'-0"
ELECTRICAL SCHEDULES ANDDETAILS
E400
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DEK
APRIL 24, 2013
JML
1302-13-01
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
22
REVISIONS
NO. DATE DESCRIPTION
EMERGENCY TRANSFER DEVICE WIRING DIAGRAMNO SCALE4
VOLTAGESENSING
BROWN
RED
BLUE
WHITE
WHT/RED
WHT/BLK
WALL SWITCH ORLIGHTING CONTROLRELAY
BLACK 120V(CAP UNUSED LEAD)
WHITE
BLACK
LAMP LEADSNOT SHOWN
1. NORMAL OPERATION: (SHOWN ABOVE) AC LIGHTING BALLAST SUPPLIED BY NORMAL LIGHTING CIRCUIT
AND CONTROLLED BY WALL SWITCH.
2. EMERGENCY OPERATION: AC LIGHTING BALLAST SUPPLIED BY GENERATOR THROUGH EMERGENCY
LIGHTING CIRCUIT AND INDEPENDENT OF WALL SWITCH POSITION.
3. EMERGENCY TRANSFER DEVICE SHALL BE BODINE #GTD, SIDELITE #PSM, OR DUAL-LITE #ATSD.
GENERATORTRANSFER DEVICE
NOTES:
AC
BALLAST
PHASE
NEUTRAL
EMERGENCY
NORMAL
NORMAL
EMERGENCY
DUPLEX RECEPTACLE (TYP.)(DESIGNATED ON PLANS)
1 1/4" TELECOMM CONDUIT(S) AS REQUIRED TOEXISTING IT CLOSET 339.
BRANCH CIRCUITCONDUIT(S)
SURFACE RACEWAY TOABOVE ACCESSIBLE CEILING
WW-14 3/4" HIGH X 1 3/4" DEEP SURFACEMETAL RACEWAY WITH LOW VOLTAGE DIVIDER.LENGTH AS SHOWN ON DRAWINGS.
DATA OUTLETS WITHIN 106 FRAME (TYP.)(DESIGNATED ON PLANS)
S
INBOARD LAMP BALLASTS
INBOARD LAMP BALLASTS
POWER/RELAY UNIT
OCCUPANCY SENSOR
SEE LIGHTING PLANS FOR ACTUAL NUMBER OF LUMINAIRES AND LOCAL CONTROLS.INSTALL AHEAD OF ALL LUMINAIRES WITHIN ROOM.
NOTES:
1.
MOUNT POWER/RELAY UNIT ONJUNCTION BOX ABOVE CEILING.
OC
H N
D
S
H N
T
TC
TIME CONTROLLED LUMINAIRES
NOTES:
1. PROGRAM TIME CLOCK SO THAT LIGHTS STAY ON FOR 12 HOURS DURING THE DAYAND TURN OFF FOR 12 HOURS DURING THE NIGHT. VERIFY PROGRAMMING WITHOWNER.
2. TIME SWITCH ALLOWS FOR TEMPORARY MANUAL OVERRIDE OF TIME CLOCK.VERIFY SETTING OF TIME SWITCH WITH OWNER.
NortheasternIllinoisUniversity
SITE PLAN
DRAWN BY
CHECKED BY
SHEET No.
DATE SCALE
BUILDING ID/NAME: BERNARD J. BROMMEL HALL
PROJECT
PROJECT NOTES
TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280
of SHEETS
t 312.440.2300f 312.440.2303www.baileyedward.com
35 East Wacker DrSuite 2800Chicago, IL60601-2308
©2013 Bailey Edward DesignDesign Firm License No. 184-001962
5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625
BE #NEIU # 11-0333-0213
1 4/24/2013 ISSUED FOR BID
KJW
W #
13.
0146
.00
- N
EIU
- V
ivar
ium
& M
arin
e O
rgan
ism
s R
enov
atio
n ||
\\s
vkjw
wna
s4\k
\13\
13.0
146.
00\R
evit1
3\M
EP
T13
_13.
0146
.00_
NE
IU S
cien
ce L
abs_
Cen
tral
.rvt
23
12" = 1'-0"
ELECTRICAL DETAILS
E401
NEIU - VIVARIUM & MARINEORGANISMS RENOVATION
DEK
APRIL 24, 2013
JML
1302-13-01
NO SCALE1SURFACE WIREWAY DETAIL
NO SCALE2OCCUPANCY SENSOR WIRING DIAGRAM
NO SCALE3TIME CLOCK WIRING DIAGRAM
TM
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2013 KJWW, P.C.
REFERENCE SCALE IN INCHES
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
0 1 2 3
ENGINEERINGCONSULTANTSExperience you can build on. PROJECT #
630.527.2320 FAX: 630.527.2321www.kjww.com
1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563
Illinois Design Firm Registration #184-000973
13.0146.00
23
REVISIONS
NO. DATE DESCRIPTION
Recommended