3Schindler 5500
Advanced technology for green performance.
DriveA high-performance gearless drive with economical and environmental friendly operation. The central suspension and variable-frequency control deliver a smooth ride, free of vibrations and jerks. The advanced compact motor is optimized to save energy, produce minimal heat and runs quietly. True comfort for the passengers. The drive levels the car precisely to the landing allowing passengers to enter and leave safely.
Traction mediaThe innovative traction medium replaces conventional steel ropes. It’s lighter, needs less space, and is quieter. Thanks to this innovation, less noise is transmitted to the car and building. The hoistway is efficiently utilized, ride comfort is significantly increased.
ControlThe highly integrated microprocessor control system optimally manages the diverse operations of single-car installations as well as groups of up to eight elevators. For individual configurations more than 100 control options are possible. Many of which provide energy-saving standby operations. When the car is empty, the car lighting and ventilation are automatically switched into energy-saving mode. During balanced travel, the frequency converter switches over to low energy consumption. Key switches or allowance for card readers are options.
Car & hoistwayThe car is centrally guided and ideally balanced, which reduces friction and energy losses. The design allows flexible hoistway and car dimensions. This means much greater planning freedom. Car and landing operating panels have easily readable LED indicators with energy-saving performance.
4 Schindler 5500
You design. We deliver.
Times SquareThe design line Times Square carries the architecture of sophisticated residential and commercial buildings into the elevator. Create a pleasant atmosphere with colorful laminates or stainless steel. Selecting bicolor adds another dimension of creativity. Choose from three LED lighting and ceiling concepts to create plenty of light whilst saving energy. The stainless steel operating panel matches the car design.
Options: Round stainless steel handrail Individual car design Unicolor or bicolor finish Mirror panels on side or rear wall Car doors in different materials and colors
BellevueFinish off your architectural concept for upmarket residential or commercial buildings with an equally attractive elevator design. The car can be dressed in a warm wood appearance or decorated with elegant, glossy surfaces. Colorful laminates and stainless steel variations blend with a choice of ceiling designs with LED lighting create an exciting appearance. The operating panel is discreetly integrated into the car. This is what we mean by elegance right down to the very last detail.
Options: Round handrail Individual car floor Mirror panels on side or rear wall Car doors in different materials and colors
Times Square (unicolor )Side wall /rear wall: Laminate Lisbon blueCeiling: Laminate greyFloor: Artificial granite grey Skirting: Stainless steel brushedLighting: Island
Times Square (bicolor)Side wall: Laminate Lisbon blueRear wall / ceiling: Laminate greyFloor: Artificial granite grey Skirting: Stainless steel brushedLighting: Island
BellevueSide wall /rear wall: Stainless steel brushedCeiling: Stainless steel mirror polishedFloor: Artificial granite black Skirting: Stainless steel brushedLighting: SquareHandrail: Round
5Schindler 5500
Park AvenueThe perfect elevator for exclusive residences or presti-gious offices. The back wall flows into the ceiling and the combination of high quality materials creates a modern atmosphere. Combine stainless steel with warm wood designs or contrast it with glossy surfaces. The elegant stainless steel operating panel perfectly comple-ments the interior design.Three LED lighting and ceiling concepts create a secure and inviting atmosphere. An elevator just as exclusive as your building.
Options: Round stainless steel handrail Individual car floor Mirror panels on side or rear wall Car doors in different materials and colors
Park AvenueSide wall: Laminate Arosa woodRear wall / ceiling: Stainless steel brushedFloor: Artificial granite black Skirting: Stainless steel brushedLighting: Strips
Times Square
Bellevue
Park Avenue
6 Schindler 5500
WallRear wall (unicolor)Side wall (bicolor)
FloorLightingCeilingRear wall (bicolor)
LaminatePalma vanilla
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Powder coatedWhite
Preparedfor customer-supplied floor
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Powder coatedGrey
Powder coatedGrey
Powder coatedGrey
Powder coatedGrey
Powder coatedGrey
Powder coatedGrey
UnicolorIsland
BicolorIsland
Unicolor
Unicolor
Unicolor
Unicolor
Unicolor
Unicolor
Unicolor
Unicolor
Unicolor
Unicolor
Bicolor
Bicolor
Bicolor
Bicolor
Bicolor
Bicolor
Bicolor
Bicolor
Bicolor
Bicolor
UnicolorSpot
UnicolorLight field*
BicolorLight field*
BicolorSpot
Black rubberSpeckled
LaminateCadiz blue
LaminateLondon grey
Artificial graniteBrown
Stainless steelLinen
LaminateValencia orange
Artificial graniteBlack
LaminateGlasgow brown
LaminateLisbon blue
Artificial graniteGrey
Stainless steelDama
Stainless steelMirror polished
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Powder coatedWhite
Stainless steelMirror polished
Unicolor Bicolor LaminateMarseille grey
Stainless steelBrushed
*available spring 2011
Times Square
7Schindler 5500
Wall FloorCeiling Lighting
LaminateArosa wood
Preparedfor customer-supplied floor
BellevueSun*
BellevueSpot*
BellevueSquare*
Black rubberSpeckled
LaminateCalais blue
Artificial graniteBrown
Stainless steelLinen
LaminateCambridge wood
Artificial graniteBlack
LaminateNancy violet
LaminateLille brown
Artificial graniteGrey
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
Stainless steelMirror polished
LaminateUdine green
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelBrushed
Stainless steelMirror polished
Stainless steelBrushed
Stainless steelBrushed
*available spring 2011
Bellevue
Catches the eye. Touches the soul.
For every finish a complementary lighting design. High quality materials professionally crafted. Energy-saving long-life LED technology.
Times Square, bicolor: Island Light field* Spot
Bellevue: Sun* Square* Spot*
Times Square, unicolor: Island Light field* Spot
Park Avenue: Square spot* Strips* Spot*
*available spring 2011
10 Schindler 5500
Landing operating panels, with position indicator and direction arrows
Landing operating panelsOption: Colored deco frame
Car position indicator and direction arrows
Operating panelFull height version. Elegant, discreet design. Matt glass display with easily readable fi ne-resolution red LED dot matrix. Push buttons with white surround illumination and red call confi rmation.
Options: Concealed attendant control compartment Key switchThree landing mounting options for door frame and wall
Car operating panel
Touch and go.
11Schindler 5500
The round stainless steel handrail with discrete mounting adds comfort for the passengers.
The spacious design of the car can be enlarged with mirrors. Choose one or two mirrors on the side wall or rear wall.
Durable push buttons with or without braille.
A rear wall mirror in full or half car height adds dimension to the car.
Plenty of room. Plenty of comfort.
12 Schindler 5500
GQkg
VKNm/s
HQm ZE
BKmm
TK mm
HKmm
Type BT mm
HT mm
BS mm
TS mm
HSGmm
HSK*mm
630 8 1.0 45 15 1 1100 1400 2200-3000 T2 900 2000-2300 1650 1750 1100 HK+1300
1.6 80 30 1 1300 HK+1400
800 10 1.0 45 15 1 1350 1400 2200-3000 C2 900 2000-2300 2025 1700 1100 HT+1300
1.6 80 30 1 1300 HK+1400
1000 13 1.0 45 15 1 1100 2100 2200-3000 T2 900 2000-2300 1650 2450 1100 HK+1300
1.6 80 30 1 1300 HK+1400
2.5 100 36 1700 2475 1800 HK+1900
13 1.0 45 15 1 1600 1400 2200-3000 C2 900 2000-2300 2125 1700 1100 HK+1300
1.6 80 30 1 1300 HK+1400
2.5 100 36 2200 1725 1800 HK+1900
1275 17 1.0 45 15 1 1200 2300 2200-3000 T2 1100 2000-2300 1975 2700 1100 HK+1300
1.6 80 30 1 1200 HK+1400
2.5 100 36 2000 2700 1850 HK+2050
17 1.0 45 15 1 1650 1700 2200-3000 C2 1100 2000-2300 2400 2025 1100 HK+1300
1.6 80 30 1 1200 HK+1400
2.5 100 36 2450 2050 1850 HK+2050
1600 21 1.0 45 15 1 1400 2400 2200-3000 C4 1300 2000-2300 2175 2800 1100 HK+1300
1.6 80 30 1 1200 HK+1400
2.5 100 36 2225 2800 1850 HK+2050
21 1.0 45 15 1 2100 1600 2200-3000 C2 1100 2000-2300 2675 1925 1100 HK+1300
1.6 80 30 1 1200 HK+1400
2.5 100 36 2700 1950 1850 HK+2050
1800 21 1.0 45 15 1 2100 1800 2200-3000 C2 1200 2000-2300 2750 2125 1500 HK+1700
1.6 80 30 1550 HK+1750
2.5 100 36 2775 2150 1850 HK+2150
GQ Load capacityVKN SpeedHQ Travel height
BK Car widthTK Car depthHK Car height
T2 Telescope doorC2/C4 Center-opening telescope doorBT Door widthHT Door height
BS Shaft widthTS Shaft depthHSG Shaft pit depthHSK Clear overhead below lifting beam* with balustrade of 700 mm on car top
HEmin = HT + 450 mmHK = HT + min. 100 mm
Numbe
r of e
ntra
nces
Hoistw
ay
Spee
d
Load
capa
city
Pass
enge
rs m
ax.
Door
Numbe
r of s
tops
max
.
Trav
el h
eigh
t
Car
Remarks:– Our equipment is designed to withstand a temperature range of 5 to 40°C– To achieve a suitable temperature for service personnel, the shaft temperature should be kept within the range of 5 to 35°C– The humidity in the shaft should not exceed 90% in monthly average and 95% in daily average without condensation– Table of dimensions as per EN81, for other country codes and specific requirements (eg. EN81-72 fire fighter elevator), please contact our local sales office– Shaft dimensions width & depth are based on clear dimension +/-25mm horizontal tolerances over the total shaft height (for shaft height > 80 m, a horizontal tolerance of +/-40mm applies)– All given information is for general reference and planning. For specific construction detail, please contact our local sales office
EN-81
Schindler 5500 MRL Planning Data
13Schindler 5500
One-sided entrance
F.F.L.
F.F.L.
F.F.L.
HQ
HT
HSG
HT
HK
HSK
HE
min
TK TS
BT
BK
BS
One-sided entrance Center-opening telescope door
One-sided entrance Telescopic door
BS
BK
BT
TSTK
For additional information, such as proposals, constructions plans, and pricing, please contact our Sales Department directly.
F.F.L. = Finished Floor Level
Height and plan view
Recommended