GAP ONLINE TUTORIALS
www.ifm-solutions.com Page 1/2 © IFM-Solutions
Tutorial G-01: Integrated Production model Setup
Objectives:
- Set up an integrated model for a gas and condensate field
- Generate IPR and VLP curves
- Input pipeline Data
The set up of a model in GAP consist on a series of steps:
1. Draw the layout of the system in GAP.
Using the short-cut icons showed below:
From left to right the icons are: Add Separator, Add Joint, Add link-pipe, Add Well, Add Tank
Draw the following layout:
2. Linking the icons with the corresponding file.
The Tank and Well icons should have an associated file created in MBAL and PROSPER respectively.
The Tank icon should be associated to the file created in the Tutorial M-03. (M-03.mbi)
The Well 1 icon should be associated to the file created in the Tutorial P-08 (P-08.out)
The Well 2 and Well 3 icons should be associated to the PROSPER files attached in the auxiliary
folder called: Aux_Files\day3\G-01_Well2.out and Aux_Files\day3\G-01_Well3.out
www.ifm-solutions.com Page 2/2 © IFM-Solutions
3. Generating IPR and VLP
Generate the IPR from the main menu in GAP selecting:
Generate | Generate well IPRs with PROSPER
Generate the VLPs from the main menu in GAP selecting:
Generate | Generate well VLPs with PROSPER
In the VLPs generation is very important to enter a wide range of conditions that will cover all
possible intersections of VLP and IPR.
Discuss the ranges of the different variables used.
4. Enter the pipeline information
Pipe WH1 to Manifold
WH2 to Manifold
WH3 to manifold
Manifold to sep joint
Length km 3 2.5 4 40
Inside diameter inches 6 6 6 11
Roughness inches 0.0006 0.0006 0.0006 0.0006
Correlation Beggs and Brill
Beggs and Brill
Beggs and Brill
Beggs and Brill
Outside Temp °F 70 70 70 70
Overall heat Transfer coef. BTU/h/F/ft2 3 3 3 3
Note: Assume a flat terrain for all the pipelines
Save the GAP file as G-01.gap