New Products
Total Chlorine Free Chlorine
Phosphate Iodine
Iron
New
Handy P
hotometers
www.milwaukeeinst.com
SPECIFICATIONS Free ChlorineRange: 0.00to2.50ppm(mg/L)Resolution: 0.01ppm(mg/L)Precision: ±0.03ppm±3%ofreading@25°CTypical EMC Dev.: ±0.01ppmLight Source: LightEmittingDiode@525nmLight Detector: SiliconPhotocellEnvironment: 0to50°C(32to122°F);RHmax95%non-condensingBattery Type: (1)1.5VAAAAuto-off: After2minutesofnon-useDimensions: 81.5x61x37.5mm(3.2x2.4x1.5”)Weight: 64g(2.25oz.)Method: AdaptationofUSEPAmethod330.5.Thereactionbetweenfreechlorineandthe DPDreagentcausesapinktintinthesample.
SPECIFICATIONS Total Chlorine Range: 0.00to3.50ppm(mg/L)Resolution: 0.01ppm(mg/L)Precision: ±0.03ppm±3%ofreading@25°CTypical EMC Dev.: ±0.01ppmLight Source: LightEmittingDiode@525nmLight Detector: SiliconPhotocellEnvironment: 0to50°C(32to122°F);RHmax95%non-condensingBattery Type: (1)1.5VAAAAuto-off: After2minutesofnon-useDimensions: 81.5x61x37.5mm(3.2x2.4x1.5”)Weight: 64g(2.25oz.)Method: AdaptationofUSEPAmethod330.5.Thereactionbetweentotalchlorineandthe DPDreagentcausesapinktintinthesample
SPECIFICATIONS PhosphateRange: 0.00to2.50ppm(mg/L)Resolution: 0.01ppm(mg/L)Precision: ±0.04ppm(mg/L)±4%ofreading@25°CTypical EMC Dev.: ±0.01ppmLight Source: LightEmittingDiode@525nmLight Detector: SiliconPhotocellEnvironment: 0to50°C(32to122°F);RHmax95%non-condensingBattery Type: (1)1.5VAAAAuto-off: After2minutesofnon-useDimensions: 81.5x61x37.5mm(3.2x2.4x1.5”)Weight: 64g(2.25oz.)Method: AdaptationoftheStandardMethodsfortheExaminationof WaterandWastewater,20thedition,AscorbicAcidmethod. Thereactionbetweenphosphateandthereagentcausesablue tintinthesample
SPECIFICATIONS IronRange: 0.00to5.00ppm(mg/L)Resolution: 0.01ppm(mg/L)Precision: ±0.04ppm±2%ofreading@25°CTypical EMC Dev.: ±0.01ppmLight Source: LightEmittingDiode@525nmLight Detector: SiliconPhotocellEnvironment: 0to50°C(32to122°F);RHmax95%non-condensingBattery Type: (1)1.5VAAAAuto-off: After2minutesofnon-useDimensions: 81.5x61x37.5mm(3.2x2.4x1.5”)Weight: 64g(2.25oz.)Method: AdaptationoftheEPAPhenantrolinemethod315B,for naturalandtreatedwaters.Thereactionbetweenironand reagentcausesanorangetintinthesample.
SPECIFICATIONS Iodine Range: 0.0to12.5ppm(mg/L)Resolution: 0.1ppm(mg/L)Precision: ±0.1ppm±5%ofreading@25°CTypical EMC Dev.: ±0.1ppmLight Source: LightEmittingDiode@525nmLight Detector: SiliconPhotocellEnvironment: 0to50°C(32to122°F);RHmax95%non-condensingBattery Type: (1)1.5VAAAAuto-off: After2minutesofnon-useDimensions: 81.5x61x37.5mm(3.2x2.4x1.5”)Weight: 64g(2.25oz.)Method: AdaptationoftheStandardMethodsfortheExaminationofWaterand Wastewater,18thedition,DPDmethod.Thereactionbetweeniodineand thereagentcausesapinktintinthesample
Recommended