View
223
Download
0
Category
Preview:
Citation preview
7/22/2019 Tor Rmg2552
1/102
(TERM OF REFERENCE : TOR)
(RAIL MOUNTED SHORE SIDE GANTRY CRANE)
40 4
-----------------------------------------------------------------------------------------------------------
1.
(RAIL MOUNTED SHORE SIDE GANTRYCRANE) 40 .. 2552 .. 2553 4
2.
2.1 40
7/22/2019 Tor Rmg2552
2/102
2.2
3. 3.1
(RAIL MOUNTED SHORE SIDE GANTRY CRANE) 40 4
3.2
- 3.3
-
(Consortium) (Joint Venture)
3.4 ISO 9000 ISO 9001
3.5 3 3
(Customer) 5
2
7/22/2019 Tor Rmg2552
3/102
3.6
3.7 / 1.10
3.8
4. 1 1.1
ISO ASA
(FULL LOAD) 40 .-
(WHEEL LOAD AT RIVER SIDE) 28
(WHEEL LOAD AT LAND SIDE) 23
3
7/22/2019 Tor Rmg2552
4/102
1.2 (STANDARDS)
BS-BRITISHSTANDARD SPECIFICATION
BS
BS : British Standard SpecificationIEC : International Electrotechnicial CommissionIEE : The Institution of Electrical Engineers, U.K.
FEM: Federation Europeanne DE La ManutentionAWS : American Welding SocietyJIS : Japanese Industrial StandardDIN : Deutsches Institute fur Normung e.V.EIT : The Engineering Institute of Thailand
NEMA : National Electrical ManufacturesAssociation
EN : European NormGB : Chinese StandardSIS : Swedish Institution Standard
1.2.1 STANDARD AND MECHANISM
4
7/22/2019 Tor Rmg2552
5/102
a) FEM Standardb) BS EN 13001-1 :2004 or
equivalentstandard
: Crane safety. Generaldesign. General principles
and requirements
c) BS EN 13001-2 :2004 or equivalent
standard
: Crane safety. Generaldesign. Load effects
1.2.2 ELECTRICALa) IEC Standardb) BS EN 60034-5 :
2001 or equivalentStandard
: Rotating electrical machines.
Degrees of protectionprovided by the integraldesign of rotating electricalmachines (IP code).Classification
1.2.3 WELDINGa) BS EN 287-1 :2004 or
equivalentstandard
: Qualification test of welders.Fusion welding. Steels
b) BSEN 288-3 :1992 or
equivalent
: Specification and approvalof welding procedures formetallic materials. Welding
5
7/22/2019 Tor Rmg2552
6/102
standard procedure tests for the arcwelding of steels
c) AWS : American Welding Society
1.2.4 PAINTINGa) SIS : Swedish Institution Standardb) BS EN ISO12944-1 : 1998 or
equivalentstandard
: Paints and varnishes.Corrosion protection of steel
structures by protective paintsystems. Generalintroduction
c) BS EN ISO12944-2 : 1998 or
equivalentstandard
: Paints and varnishes.Corrosion protection of steelstructures by protective paintsystems. Classification ofenvironments
d) BS EN ISO12944-3 : 1998 or
equivalentstandard
: Paints and Varnishes.Corrosion Protection of SteelStructures by ProtectivePaint Systems. DesignConsiderations
e) BS EN ISO12944-4 : 1998 or
equivalent
standard
: Paints and varnishes.Corrosion protection of steelstructures by protective paint
systems. Types of surfaceand surface preparation
6
7/22/2019 Tor Rmg2552
7/102
f) BS EN ISO 12944-5 : 1998 or
equivalent
standard
: Paints and varnishes.Corrosion protection of steelstructures by protective paint
systems. Protective paintsystems
g) ISO 8501 Preparation of steelsubstrates before applicationof paints and related
products. Visual assessmentof surface cleanliness
h) ISO 8502 Preparation of steelsubstrates before applicationof paints and related
products. Tests for theassessment of surfacecleanliness
i) ISO 8503 Preparation of steelsubstrates before application
of paints and relatedproducts. Surface roughnesscharacteristics of blast-cleaned steel substrates
j) ISO 8504 Preparation of steelsubstrates before applicationof paints and relatedproducts. Surface preparation
7
7/22/2019 Tor Rmg2552
8/102
methods
1.2.5 GENERAL
BS 7121-3 : 2000 : Code of practice for safeuse of cranes. Mobile cranes
All units shall be SI units (metric)
8
7/22/2019 Tor Rmg2552
9/102
2
(DRAWING)
2.1 2.1.1
(OUT REACH) (RIVER SIDE RAIL) 30
(BACK REACH)
(LAND SIDE RAIL) 10 22 ( )
(GANTRY RAIL SPAN) 15 (OVERALL CRANE
WIDTH (BUMPER EXTENDED TO BUMPEREXTENDED)) 30 CROSS BEAM (CLEAR HEIGHT
UNDER CROSS BEAM) 8 (TOTAL LIFTING
HEIGHT) 33 23
9
7/22/2019 Tor Rmg2552
10/102
10 (OVERALL CRANE
HEIGHT) (GENERAL
ARRANGEMENT) -
2.1.2 (OPERATION SPEEDS) (HOISTING SPEED) 40 (RATED LOAD)
45 90
(TROLLEY TRAVEL SPEED)
(FULL LOAD) 120 (GANTRY TRAVEL
SPEED) 40 - (BOOM
HOISTING TIME FOR ONE COMPLETEHOISTING AND LOWERING OPERATION) 10
2.1.3 TRAVEL TYPE A100 DIN 536
2.1.4 (STANDARDIZATION) (LAY
10
7/22/2019 Tor Rmg2552
11/102
- OUT) (COMPONENTS) (INTERCHANGEABILITY AMONG THE CRANES)
-
2.2 CLASSIFICATION OF CRANE 24
STRUCTURES
BS .-(1) Class of Utilisation : U7 (2 millionloading cycles)
(2) State of Loading : Q2(3) Group Classification : A7
(4) Impact factor : 1.4(5) Duty factor : 0.9(6) Nominal Load spectrum factor : 0.80 of rated
capacityMECHANISMS
Class of Utilisation State ofLoading Group Classification
11
7/22/2019 Tor Rmg2552
12/102
Hoist T8 L3 M8Traveres T8 L3 M8Travel T5 L2 M5Boom hoistT3 L3
M4
2.3 CLIMATIC CONDITIONMAXIMUM AMBIENT TEMPERATURE
: 40o CRAINFALL - AVERAGE ANNUAL
: 1800 MMHUMIDITY
: 90 %
3
3.1, 3.4, 3.5 3.6
3.1 (GEARS AND REDUCERS)
(HOIST) (BOOM) TROLLEY GANTRY TRAVEL
12
7/22/2019 Tor Rmg2552
13/102
DRAIN GATEVALVES
(HOIST) (BOOM) TROLLEY GANTRYTRAVEL HEAVY DUTY
1 80 dBA (EMPTY MAXIMUM OPERATIONSPEED)
(GEARS ANDREDUCERS) ISO 9000 9001
-
3.2 (SHEAVES) (SHEAVES)
30 (WIREROPE)
50-65 SHORE HARDNESS
13
7/22/2019 Tor Rmg2552
14/102
SPLIT TYPEBRACKET
BOOM HOIST
3.3 (ROPE DRUM)
HIGH STRENGTH STEEL
(ROPE DRUM) 30 (WIRE
14
7/22/2019 Tor Rmg2552
15/102
ROPE) SPREADER BOOM
MAIN HOIST BOOM HOIST 4
BOOM HOIST
3.4 (WIRE ROPE) (HOIST SYSTEM)
FULLY LUBRICATED PLASTIC LAYERBETWEEN THE STEEL CORE AND THE OUTERSTRANDS VERY HIGH BREAKING LOAD AND
GOOD RESISTANCE AGAINST DRUM CRUSHING MAIN
HOIST BOOM HOIST (SAFETY FACTOR) 6
(REEVING SYSTEM)
MAIN HOIST (RAISED CONDITION)
15
7/22/2019 Tor Rmg2552
16/102
MAIN HOIST BOOMHOIST GIRDER
.-
MAIN HOIST 100,000
BOOM HOIST
MACHINERY HOUSE GIRDER
3.5 (GREASE LUBRICATION
SYSTEM) (CENTRALISED
LUBRICATION SYSTEM) CMS (CRANE MANAGEMENTSYSTEM) .-
TOP OF MAST 1
16
7/22/2019 Tor Rmg2552
17/102
(END OF BOOM) 1 (MID SECTION OF
BOOM) 1 GIRDER (END OF GIRDER) 1 MACHINERY HOUSE 1
5 6 WEATHER PROOF 35 CM3/MIN
25 4 ( 1 ) 10 GANTRY TRAVELOPERATION GANTRY BOGIE
STAINLESS
STEEL 2 .
10 .
6 .
17
7/22/2019 Tor Rmg2552
18/102
HEAVY DUTY - 14 OUNCES/MIN 15 1 MACHINERY HOUSE (TROLLEY PARKING) FESTOON CABLE CARRIER
MACHINERY HOUSE
2 30,000 (MAIN
HOIST SYSTEM) -
3.6 (COMPRESSED AIR SYSTEM) ROTARY VANE ,
, AFTER COOLER DRAIN MACHINERY HOUSE 14.7 / 10 BAR
IP 55, INSULATION CLASS F, 380 - 415V, 3P, 50 Hz
18
7/22/2019 Tor Rmg2552
19/102
.-AUTO-UNLOADER VALVESAFETY VALVEAIR PRESSURE GAUGEHOUR METERWARNING LAMPS
VIBRATIONDAMPERS MACHINERY HOUSE
80dBA 1
(AIR RECEIVER) AFTERCOOLER MACHINERY HOUSE
STAINLESSSTEEL 50 .
ASTM FLEXIBLE AIR
HOSES GLOVE
VALVE
SEPERATOR , LUBRICATOR , REGULATOR AUTOMATIC MOISTURE EJECTOR .-
19
7/22/2019 Tor Rmg2552
20/102
7/22/2019 Tor Rmg2552
21/102
JIC 37
NPT SAE
3.8 BOLTS AND NUTS BOLTS AND NUTS ISO
BOLTS AND NUTS
EFFECTIVE METHODS
BOLT AND NUTS
2 BOLT AND NUTS STAINLESS STEEL
LIMIT SWITCH JUNCTION BOX
BOLT AND NUTS HIGH TENSILE STAIRS,LADDERS PLATFORMS
3.9 (BEARING) ANTI-FRICTION
(PIN CONNECTIONS) PRE -
21
7/22/2019 Tor Rmg2552
22/102
LUBRICATED 30 KW, ,
NTN, SKF,FAG, NSK
3.10 (FIRE EXTINGUISHERS)
.- (MACHINERY ROOM) DRY
POWDER 4.5 . 4 (OPERATOR 'S CABIN) BCF
1.5 . 1 (ELECTRIC CONTROLROOM) BCF 1.5 . 2
(CHECKER'S CABIN)DRY POWDER 4.5 . 2
FIRE-SMOKE DETECTOR
FIRE SMOKE DETECTOR
22
7/22/2019 Tor Rmg2552
23/102
4
4.1 (WELDING)
BS EN 287-1 BS EN 288-3
AUTOMATIC SEMIAUTOMATIC PROCESS TENSILE STRENGTH
NON
DESTRUCTIVE BS EN 287-1 BS EN 288-3
4.2 (PAINTING) BRITISH CODE OF
PRACTICE
ZINC EPOXY PAINTING SYSTEM
23
7/22/2019 Tor Rmg2552
24/102
BLAST CLEAN SA 2.5 SWEDISH STANDARD SIS 055900
EPOXY ZINC RICH PRIMER 1 - 25
POWER TOOL OR BLAST
CLEANING SIS ST3 SA 2.5 EPOXY ZINC RICH PRIMER
1 - 70
EPOXY MICACEOUS IRON OXIDE 1 100
POLYURETHANE 1 100
295 POWER TOOL OR BLAST
CLEANING SIS ST3 SA 2.5 EPOXY ZINC RICH PRIMER
24
7/22/2019 Tor Rmg2552
25/102
1 95
HIGH BUILD EPOXYPOLYAMIDE 1 100
195
POWER TOOL OR BLAST
CLEANING SIS ST3 SA 2.5 EPOXY ZINC RICH PRIMER
1 70 MICACEOUS IRON OXIDE
1 100
POLYURETHANE 1 50
245
CHIPPING AND POWER
25
7/22/2019 Tor Rmg2552
26/102
BRUSHING SIS ST3 ; CLEAN SURFACE EPOXY ZINC STABILISING
PRIMER 2 100
POLYURETHANE 3 - 150
-
2 4
26
7/22/2019 Tor Rmg2552
27/102
5
5.9 5.17 5.1 (STEEL STRUCTURE)
(GENERALARRANGEMENT) -
(WATER SIDE AND LAND SIDETROLLEY GIRDER SUPPORT BEAM ) (LEGS STRUCTURE)
LEGS PORTAL
Deflection Out Reach 15 M/S .-
REQUIREMENTS
1. DEFLECTION IN THEDIRECTION OF TROLLEY
MAX ALLOWABLEDEFLECTION
27
7/22/2019 Tor Rmg2552
28/102
7/22/2019 Tor Rmg2552
29/102
DEFLECTION
BOOM GIRDER LATCHTTICE
BOOM, GIRDER TROLLEY (OVERALL WIDTH) 6 (CENTER LINE) 3
LEG, PORTAL SILL BEAMS
HIGH TENSILE STEEL PLATE BS 7668 : 2004 FULLYWELDED BOX
HORIZONTAL BEAM DIAGONAL STAY RIVER SIDE LAND SIDE
(CORROSION)
- BS EN 13598-1 : 2003
FLOATING CRANE
(LEGS)
29
7/22/2019 Tor Rmg2552
30/102
7/22/2019 Tor Rmg2552
31/102
SAFETY BACK HOOP 250 .
0.38-0.45 RAILING BRACKET
6 (LANDING)
PLATFORM LANDING
(INCLINED STAIRS) 45
(LANDING) 3-5
2.00 1.8
(RAIL CENTER) 600 .
200 . 6 . NON SLIPGALVANISED STEEL
CHEQUERED PLATES
31
7/22/2019 Tor Rmg2552
32/102
7/22/2019 Tor Rmg2552
33/102
7.5 KN/ m2 (UDL) SAFE ACCESS PERMANENT
PLATFORM GIRDER FESTOON CABLE
5.3 (TROLLEY FRAME) (SELF
PROPELED TROLLEY) (Double Flange)
(BUFFER) HYDRAULICSPRING 4 TROLLEY
FRAME
TROLLEY FRAME
(RAISEDPOSITION) TROLLEY FRAME (LOW SPEED)
MECHANICAL STOPPER BOOM GIRDER TROLLEY FRAME
(BOOM ISLOWERED) MACHANICAL STOPPER
33
7/22/2019 Tor Rmg2552
34/102
7/22/2019 Tor Rmg2552
35/102
7/22/2019 Tor Rmg2552
36/102
7/22/2019 Tor Rmg2552
37/102
7/22/2019 Tor Rmg2552
38/102
7/22/2019 Tor Rmg2552
39/102
7/22/2019 Tor Rmg2552
40/102
7/22/2019 Tor Rmg2552
41/102
PAD TELESCOPIC BEAM
- TROLLEY TRAVEL MECHANICALLOCK - STOPPER 20 40 45
OVERHEIGHT TELESCOPIC BEAM TWIST LOCK PIN BEAM 50 . 10
TWIST LOCK, FLIPPER
- SPREADER HYDRAULIC (OVERHEATING)
TAPPING POINT SHUT OFFVALVE QUICK COUPLING
SETTING POINT FLEXIBLE HYDRAULIC HOSE
SPREADER JUNCTION BOX
(WATER-TIGHT) VIBRATION DAMPER
41
7/22/2019 Tor Rmg2552
42/102
-
FLIPPER FLIPPER
LOCK / UNLOCK
SPREADER 4 .-
SPREADER ( SQUARELY LANDED )
LOCKED POSITION UNLOCKED POSITION LIMIT SWITCH SPREADER
PROXIMITY TWIST LOCK
TOP OF CONTAINER DETECTIONS HEAD
BLOCK (CAPACITY SIGN)
SPREADER 2
5.10 SPREADER LIST, TRIM AND SKEW ADJUSTING
42
7/22/2019 Tor Rmg2552
43/102
DEVICES TRIM
5 LIST
6 SKEW
6 TRIM, LIST SKEW ADJUSTING
MECHANISM SPREADER HEAD BLOCK
CENTER
5.11 ANTI-SWAY SYSTEM SPREADER
TROLLEY ELECTRONIC SWAY
CONTROL SYSTEM ANTI-SWAY
SPREADER 4.5 ( SPREADER) TROLLEY FULL LOAD + 50 5
43
7/22/2019 Tor Rmg2552
44/102
ANTI-SNAG SPREADER SPREADER, WIRE ROPE
5.12 (OPERATOR'S CABIN)
(ERGONOMICCALLY DESIGN)
(WORKINGPOSITION)
44
7/22/2019 Tor Rmg2552
45/102
2
.
(TRAYOR SUPPORT)
OIL RESISTANT NITRILE RUBBERSHEET
1
/ 1 INVERTER
18,000 BTU
RESISTANT SAFETY
GLASS BS.6206 : 1981
4
45
7/22/2019 Tor Rmg2552
46/102
SAFETY BAR
DAYLIGHT
270 -
CONSOLE 2 MAINHOIST, GANTRY LOCK & UNLOCK SWITCH TROLLEY BOOMHOIST CONSOLE
.-
46
7/22/2019 Tor Rmg2552
47/102
7/22/2019 Tor Rmg2552
48/102
7/22/2019 Tor Rmg2552
49/102
(GALVANIZEDSTEEL) (CORRUGATED PLATE) SELF TAPPING SCREW
- 2 1
600 . 4 (LOW NOISE LEVEL)
.-
1. (VENTILATION FAN) 80 dBA2. (MOTOR
COOLING FAN) 1
80 dBA3.DURING ACCELERATION AND
49
7/22/2019 Tor Rmg2552
50/102
DECELERATION OF MAIN HOIST AND TROLLEYMECHANISMS AT MAXIMUM SPEED 95 dBA
4.DURING BOOM HOIST OPERATE 90 dBA
1 - 85 dBA
(HATCH & COVER)
-
(OVERHEADMAINTENANCE HOIST) 1
HOIST SPEED 10
50
7/22/2019 Tor Rmg2552
51/102
7/22/2019 Tor Rmg2552
52/102
7/22/2019 Tor Rmg2552
53/102
7/22/2019 Tor Rmg2552
54/102
7/22/2019 Tor Rmg2552
55/102
7/22/2019 Tor Rmg2552
56/102
DOUBLE-LEAF HINGED DOOR
0.75 x 1.00 x
2.10 -
5
SAFETY GLASS 3 .
1
3
1 (MAIN CONTROL PANNEL)
-
56
7/22/2019 Tor Rmg2552
57/102
7/22/2019 Tor Rmg2552
58/102
7/22/2019 Tor Rmg2552
59/102
7/22/2019 Tor Rmg2552
60/102
7/22/2019 Tor Rmg2552
61/102
6.5 FESTOON CABLE FESTOON CABLE
10 % 1
CORE 10 % FESTOON CABLE CARRIERS
HEAVY DUTY HIGH PERFORMANCE
MAIN ROLLER ADIPRENE POLYAMIND (PRE-LUBRICATED)
FESTOON CABLE
RUBBER BUFFER DAMPING DEVICE RUBBER ROPE TENSION RELIEF ROPE
GALVANIZED STEEL ROPE
6.6 CABLE REEL SYSTEM MONO-SPIRAL, BI-
DIRECTIONAL ,
61
7/22/2019 Tor Rmg2552
62/102
7/22/2019 Tor Rmg2552
63/102
MAINHOIST TROLLEY CONNECTOR BREAKER INTERLOCK IP65 SAFETY INSULATED UL, VDE CONNECTOR, BREAKER
CABLE REEL
HIGH VOLTAGE
6.7 LIMIT SWITCHES LIMIT SWITCHES
HEAVY DUTY NEMA IP 65
PROXIMITY SENSOR MAGNETICSWITCH IP67 WITHSTANDING SHOCK
LIMIT SWITCHES HEAVY DUTY TROLLEY
BOOM 5 GEAR LIMIT SWITCHES OVER
63
7/22/2019 Tor Rmg2552
64/102
7/22/2019 Tor Rmg2552
65/102
7/22/2019 Tor Rmg2552
66/102
7/22/2019 Tor Rmg2552
67/102
7/22/2019 Tor Rmg2552
68/102
7/22/2019 Tor Rmg2552
69/102
7/22/2019 Tor Rmg2552
70/102
7/22/2019 Tor Rmg2552
71/102
7/22/2019 Tor Rmg2552
72/102
7/22/2019 Tor Rmg2552
73/102
7/22/2019 Tor Rmg2552
74/102
7/22/2019 Tor Rmg2552
75/102
7/22/2019 Tor Rmg2552
76/102
3
1
4 WHIP 3 dB
1
5 - 1
6.12 ELECTRICAL SUPPLY OUTLETS 230 V 15 A SOCKET OUTLETS
SWITCH BS1363 .-1. MACHINERY HOUSE
4 2. ELECTRIC CONTROL ROOM 4
3. BOOM END1
4. GIDER END1
5. TOP OF MAST1
6. ALONG THE BOOM AND GIDER3
7. SEA SIDE LEG1
8. LAND SIDE LEG
76
7/22/2019 Tor Rmg2552
77/102
7/22/2019 Tor Rmg2552
78/102
7/22/2019 Tor Rmg2552
79/102
7/22/2019 Tor Rmg2552
80/102
7/22/2019 Tor Rmg2552
81/102
7/22/2019 Tor Rmg2552
82/102
7/22/2019 Tor Rmg2552
83/102
(PRINCIPAL DIMENSIONS, SPEEDAND CAPACITY OF THE CRANE)
7 7.1 PLANMAINTENANCE SYSTEM 2,000 5 (OPTION)
PLAN MAINTENANCE SYSTEM 2,000 5
PART NUMBER LISTS
83
7/22/2019 Tor Rmg2552
84/102
7.2 (COMPUSALY SPAREPARTS)
.-
7.2.1 MASTER CONTROLLERS DIGITALSIGNAL 4 ( 2 2 )
7.2.2 PLC () 2
7.2.3 SPEED DRIVE CONTROL HOIST MOTOR 2
7.2.4 SPEED DRIVE CONTROL
TROLLEY 2 7.2.5 SPREADER 1
7.3 4
(OPERATION ANDINSTRUCTION MANUAL) (REPAIR AND
MAINTENANCE MANUAL)
(MANUAL ON PERFORMANCE TESTING ANDCALIBRATION OF CRANE)
84
7/22/2019 Tor Rmg2552
85/102
7/22/2019 Tor Rmg2552
86/102
7/22/2019 Tor Rmg2552
87/102
7/22/2019 Tor Rmg2552
88/102
PRINTER 6 2.COMPUTER NOTE BOOK
- (UPLOAD orDOWNLOAD PARAMETER) PLC, SPEED DRIVECONTROL etc. (PARAMETER) 2
CPU INTEL CORE 2 DUO 2.0 GHz
HARD DISK 160 Gb RAM DDR 2 2 Gb DISPLAY CARD
WINDOW XP WIRELESS NETWORK
5. 1.
() .-
1.1
88
7/22/2019 Tor Rmg2552
89/102
1.2 INTERNATIONAL ACCREDITATION FORUM
1.3
ISO 9000 ISO 9001
- ( 1.1- 1.3) -
-
2.
89
7/22/2019 Tor Rmg2552
90/102
7/22/2019 Tor Rmg2552
91/102
2.3
3.
-
15
4. 4.1
4.2 480
91
7/22/2019 Tor Rmg2552
92/102
5. 5.1
4 () CABLE CONNECTION SHAFT
5.2 7,000 60
20 5.3 - 5.2
6.
6.1
.-6.1.1
/
7
92
7/22/2019 Tor Rmg2552
93/102
7/22/2019 Tor Rmg2552
94/102
6.3 8.1.1 8.1.2 -
24
6.1 6.2 6.3
7.7.1
(TESTING REPORTS) 30
7.2
7.2.1
94
7/22/2019 Tor Rmg2552
95/102
- 7 -
7.2.2
50
8. 8.1
(PREVENTIVE MAINTENANCE)
365 .-
95
7/22/2019 Tor Rmg2552
96/102
8.1.1 7
8.1.2
1
2 WORK PERMIT 24
8.1.3 1
( 6.8)
96
7/22/2019 Tor Rmg2552
97/102
24
8.1.4
4 24
8.2 15 .-
8.2.1 8.2.2 8.2.3
8.2.4.
8.3
5
97
7/22/2019 Tor Rmg2552
98/102
9. 9.1
9.2 30 -
9.3
2 3 4
9.4
98
7/22/2019 Tor Rmg2552
99/102
9.5 .-
9.5.1 .-
CLASSIFICATION OF CRANE 2
4
5
9.5.2
9.5.3 7.2
9.5.4 7.3
9.5.5 7.5 7.6
9.5.6
9.5.7
99
7/22/2019 Tor Rmg2552
100/102
9.5.8 5 RE3 (EUROPEAN SCALE OFDEGREE OF RUSTING FOR ANTI CORROSIVEPAINTS)
9.5.9
(INTERCHANGE ABILITYAMONG THE CRANES) 2.1.4
9.5.10
PLAN MAINTENANCE SYSTEM 2,000 5 9.5.11
-
() (Original Brand)
100
7/22/2019 Tor Rmg2552
101/102
6. 90
7. 480
8.
920,000,000.00 ()
(TOR)
13 444 - 10110 0-2269-5300 0-2249-4229
E-mail : pitak_s @port.co.th www.port.co.th
.
101
7/22/2019 Tor Rmg2552
102/102
102
Recommended