PERIMETER INSULATION FROM RISING WALL TOUNDERSIDE OF EXTERNAL INSULATION TO REDUCETHE IMPACT OF THERMAL BRIDGING
AIRTIGHT LAYER SEALED AT FLOOR SLAB
EXISTING CONCRETE WINDOW CILLS REMOVED ANDREPLACED WITH PRESSED METAL CILLS WITHEXTERNAL INSULATION RETURNED TO UNDERSIDEOF CILL
150MM KINGSPAN KOOLTHERM K7EXTERNAL INSULATION
AIRTIGHT LAYER PLASTERED INTO WINDOWREVEAL & TAPED TO WINDOW FRAME
EXISTING 215MM MASS CONCRETE WALL
EXISTING 18MM PEBBLEDASH FINISH
10MM POLYMER RENDER FINISH
18MM PLASTER INTERNALLY
200MM REINFORCED CONCRETE SLAB
VISQUEEN RADON MEMBRANE
200MM KINGSPAN KOOLTHERM K3 FLOORBOARD
75MM CONCRETE SCREED WITH UNDERFLOOR HEATINGPIPES
18MM ENGINEERED SEMI-SOLID TIMBER FLOORING LAID ONSIKABOND LIQUID BATTEN SYSTEM
150MM KINGSPAN K5 EXTERNAL WALLINSULATION
10MM POLYMER RENDER FINISH
EXISTING DOUBLE GLAZED WINDOWS REMOVED &REPLACED WITH NEW TRIPLE GLAZEDTHERMALLY BROKEN MUNSTER JOINERY PASSI VALUCLAD WINDOWS
AIRTIGHT LAYER PLASTERED INTO WINDOWREVEAL & TAPED TO WINDOW FRAME
EXTERNAL INSULATION FIXED TO EXISTINGPEBBLEDASH RENDER & RETURNED TO MEET THENEW WINDOW FRAME
uPVC FASCIA GRILLE UNIT FIXED WITHTHERMALLY BROKEN FIXINGS TO FASCIA BOARD
EAVES VENTILATOR TRAY SKIRT DRESSED INTOGUTTER
CRYOGEL Z FLEXIBLE AEROGEL BLANKETINSULATION
uPVC EAVES VENTILATOR TRAY
100MM KNAUF EARTHWOOL RAFTER ROLL 32
TYVEK SUPRO BREATHER MEMBRANE
KINGSPAN KOOLTHERM K7 PITCHEDROOF BOARD
100MM KNAUF EARTHWOOL RAFTER ROLL 32BETWEEN CEILING JOISTS WITH 200MM KNAUFEARTHWOOL RAFTER ROLL 32 LAID DRESSEDOVER
TYVEK SD2 VCL VAPOUR BARRIER
STUDY
DINING
LIVING
FAMILYAREA
WC
BEDROOM
BEDROOM
LANDING
BATHROOM
STAIRS
STORE
STORE
EXTERNAL INSULATION FIXED TOEXISTING RENDERED WALLS
EXISTING DOUBLE GLAZEDWINDOWS REMOVED & REPLACEDWITH NEW TRIPLE GLAZEDTHERMALLY BROKEN WINDOWS
ADDITIONAL INSULATION INSTALLEDIN ATTIC SPACE & ALONG SLOPEDCEILING & EAVES VENTILATION ADDED
BUILDING EXTENDED TO THE REAR TOCREATE A MORE FEXIBLE LAYOUT &MAXIMISE THE RETURN ON THE INVESTMENT
EXISTING FLOOR REMOVED & REPLACEDWITH NEW CONRETE FLOOR WITH INSULATION& UNDERFLOOR HEATING
WINDOWS 0.6 W/m2K
FLAT ROOF 0.15 W/m2K
ROOFLIGHT 1.24W/m2K
SLOPED CEILING 0.13 W/m2K
FLAT CEILING 0.12W/m2K
FLOOR 0.09 W/m2K
WINDOWS 0.6 W/m2K
WALLS 0.14 W/m2K
HEAT PUMP
MANIFOLD
FLOORSTANDINGUNIT
SOLARCOLLECTORS
EXPANSIONVESSEL
WALLS U VALUE & CONDENSATION DIAGRAM FLAT CEILING U VALUE & CONDENSATION DIAGRAM SLOPED CEILING U VALUE & CONDENSATION DIAGRAM FLAT ROOF U VALUE & CONDENSATION DIAGRAM GROUND FLOOR U VALUE & CONDENSATION DIAGRAM
nZEB GROUND FLOOR RETROFIT LAYOUT nZEB FIRST FLOOR RETROFIT LAYOUT
CUTAWAY VIEW OF RETROFIT LAYOUT MODEL VIEW OF RETROFIT FABRICMEASURES
AXO VIEW OF FIRST FLOOR AXO VIEW OF EXTENDED GROUND FLOOR
EXISTING BASELINE BEREND OF TERRACE
EXISTING BASELINE BERMID & GABLE TERRACE
nZEB RETROFIT BER
DETAIL SECTION THROUGH RETROFITWALL AT GROUND FLOOR LEVEL
DETAIL SECTION THROUGH RETROFIT WALLAT FIRST FLOOR LEVEL
DETAIL SECTION THROUGH RETROFITWALL AT CEILING/ROOF LEVEL
VIEW FROM KITCHEN TO NEW FAMILY AREA
VIEW OF KITCHEN / DINING AREA
VIEW FROM FAMILY AREA OF KITCHEN / DINING AREA
VIEW FROM LIVING STUDY AREA
CALCULATED U VALUES THROUGH RETROFITTED FABRIC ELEMENTS
VIEW OF EXTENSION TO THE REAR OF THE CRUMLIN COTTAGE
HEATING SCHEMATIC THROUGH RETROFITTED CRUMLIN COTTAGEPRIMARY ENERGY USAGE COMPARISION FOR BASELINE & RETROFIT
HEAD & EAVESHEAD ONLY
GROUND FLOOR
CORNER
OPE - LINTEL
OPE - JAMB
DT 774 - RETROFIT TECHNOLOGY MODULE ARCH - 1280TIM LAVIN D14124545 - PROJECT NO.6 - YEAR 2015
END OF TERRACE BASELINE FABRIC HEAT LOSS END OF TERRACE RETROFIT FABRIC HEAT LOSS
END OF TERRACE BASELINE HEAT USAGE END OF TERRACE RETROFIT HEAT USAGE
CILL