THESE DRAWINGS ARE NOT TO BE SCALED. ALL DRAWINGS, …

Preview:

Citation preview

1:12

RA

MP

DO

WN

EXTENT OF MECH. ROOM ABOVE

EXTENT OF FAN ROOM ABOVE

MECH.

SL

SL SL

SL

THESE DRAWINGS ARE NOT TO BE SCALED.

ALL DRAWINGS, THE DESIGN, AND THE DETAILSTHEREON REMAIN THE PROPERTY OF THEARCHITECT AND ARE NOT TO BE ALTERED,RE-USED OR REPRODUCED WITHOUT THEARCHITECT'S EXPRESS WRITTEN CONSENT.

THE CONTRACTOR MUST FIELD VERIFY ALLDIMENSIONS AND MUST CONFIRM & CORRELATEALL DETAILS WITHIN THE FULL DRAWINGPACKAGE BEING RESPONSIBLE FOR SAMETHROUGHOUT CONSTRUCTION, REPORTINGANY DISCREPANCIES TO THE ARCHITECT PRIORTO COMMENCING THE RELEVANT WORK

ALL DRAWINGS, DETAILS & SPECIFICATIONSREPRESENTED IN THE DRAWINGS ARE TO BEUSED FOR CONSTRUCTION ONLY WHEN ISSUEDBY THE ARCHITECT AND NOTED ACCORDINGLYIN THE "ISSUE/REVISIONS" BOX HEREON.

C .

1413August 2014

V. PaniciC. Elwell

1/16" = 1'-0"

1A2 EXISTING

MUSICROOM

EQUIP.STOR.

GirlsWash Rm.

BoysWash Rm.

BOYSWASH RM.

GIRLSWASH RM.

EXISTINGGYM

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGROOM

EXISTINGROOM

EXISTINGCLASSROOM

822 sq.ft.

EXISTINGSTAGE

CUST.

EXISTINGCLASSROOM

EXISTINGLIBRARY

KINDERGARTEN

STAFF ROOM

Meeting Rm.

Office

Principal's Office

EXISTINGMECHANICAL

OFFICE

EXISTINGCUSTODIAN

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGCLASSROOM

KINDERGARTEN

KINDERGARTEN

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGCLASSROOM

Kinder-garten

Storage

NewResource

Room

NewSensory Rm.

NewMeeting Rm.

NewStaff

Work Rm.

specialneeds

ExistingJanitorial

Staff Work Rm.

ExistingStorage

ADMINISTRATION

display case

BOYSCHANGEROOMGIRLS

CHANGEROOM

Health Rm.

I.T.Room

EQUIP.STOR.

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGCLASSROOM

EXISTINGGYM

NEWOUTDOORSTORAGE

EXISTINGGYM

STORAGE

NEWCHANGEROOM

NEWCHAPEL

RENOVATEDCHANGEROOM

2A2

1. Issued for Permit/Tender Aug. 15/14 CRE

ION

3473

ON

R IOOCI

ARCHITECTSOFTA

AT

SA SAug. 15, 2014

W#

122-2B.F.W.R.

100-5EXISTING

CORRIDOR

2

1

05RENOVATED

CHANGE ROOM

08NEW

CHAPEL

06EXISTINGVESTIBULE

2

1

07EXISTING

WASHROOM

(3) 5 x 3 1/2" x 1/4"STEEL LINTEL

WITH 6" BEARINGON SOLID FILLED CONC. BLOCK

(3) 5 x 3 1/2" x 1/4"STEEL LINTEL WITH 6" BEARINGON SOLID FILLED CONC. BLOCK

(2) 5 x 5" x 1/4" STEEL LINTELWITH 6" BEARING ON SOLID FILLED CONC. BLOCK

01OUTDOORSTORAGE

(2 hr. rated)

EXISTINGGYM

3

02EXISTING

GYM STORAGE

03NEW

CHANGE ROOM

04NEW

WASHROOM

(2) 5 x 5" x 1/4" STEEL LINTELWITH 6" BEARING ON SOLID FILLED CONC. BLOCK

(3) 5 x 3 1/2" x 1/4" STEEL LINTELWITH 6" BEARINGON SOLID FILLED CONC. BLOCK

#

THESE DRAWINGS ARE NOT TO BE SCALED.

ALL DRAWINGS, THE DESIGN, AND THE DETAILSTHEREON REMAIN THE PROPERTY OF THEARCHITECT AND ARE NOT TO BE ALTERED,RE-USED OR REPRODUCED WITHOUT THEARCHITECT'S EXPRESS WRITTEN CONSENT.

THE CONTRACTOR MUST FIELD VERIFY ALLDIMENSIONS AND MUST CONFIRM & CORRELATEALL DETAILS WITHIN THE FULL DRAWINGPACKAGE BEING RESPONSIBLE FOR SAMETHROUGHOUT CONSTRUCTION, REPORTINGANY DISCREPANCIES TO THE ARCHITECT PRIORTO COMMENCING THE RELEVANT WORK

ALL DRAWINGS, DETAILS & SPECIFICATIONSREPRESENTED IN THE DRAWINGS ARE TO BEUSED FOR CONSTRUCTION ONLY WHEN ISSUEDBY THE ARCHITECT AND NOTED ACCORDINGLYIN THE "ISSUE/REVISIONS" BOX HEREON.

C .

1413August 2014

V. PaniciC. Elwell

1/4" = 1'-0"

1A1

2A1

1. Issued for Permit/Tender Aug. 15/14 CRE

I ON

3473

ON

R IOOCI

ARCHITECTSOFTA

AT

SA SAug. 15, 2014

3A2

3A2

01OUTDOORSTORAGE

(2 hr. rated)

EXISTINGGYM

02EXISTING

GYM STORAGE

03NEW

CHANGE ROOM

04NEW

WASHROOM

VT

CSH

CSH

VT

VT

100-5EXISTING

CORRIDOR

05RENOVATED

CHANGE ROOM

08NEW

CHAPEL

06EXISTINGVESTIBULE

07EXISTING

WASHROOM

CT

PT-2

a b c d b ac d b a c d b a c d a b c a d c b a d c b a

PT-2

CARPET TILE POSITIONING:a - full length northb - full length southc - centered with 6 full tilesd - centered with 5 full tiles

CT-

2B

CT-

2A

CT-

1

Porcelain Tile:Designation Product Specification

PT-1A

PT-1B

PT-2

Vinyl Composition Tile:

Designation Product Specification

VT

Carpet:

CT

Wall Base:

PT-B

RB

CT-

1

CT-

2B

CT-

2A

THESE DRAWINGS ARE NOT TO BE SCALED.

ALL DRAWINGS, THE DESIGN, AND THE DETAILSTHEREON REMAIN THE PROPERTY OF THEARCHITECT AND ARE NOT TO BE ALTERED,RE-USED OR REPRODUCED WITHOUT THEARCHITECT'S EXPRESS WRITTEN CONSENT.

THE CONTRACTOR MUST FIELD VERIFY ALLDIMENSIONS AND MUST CONFIRM & CORRELATEALL DETAILS WITHIN THE FULL DRAWINGPACKAGE BEING RESPONSIBLE FOR SAMETHROUGHOUT CONSTRUCTION, REPORTINGANY DISCREPANCIES TO THE ARCHITECT PRIORTO COMMENCING THE RELEVANT WORK

ALL DRAWINGS, DETAILS & SPECIFICATIONSREPRESENTED IN THE DRAWINGS ARE TO BEUSED FOR CONSTRUCTION ONLY WHEN ISSUEDBY THE ARCHITECT AND NOTED ACCORDINGLYIN THE "ISSUE/REVISIONS" BOX HEREON.

C .

1413August 2014

V. PaniciC. Elwell

1/4" = 1'-0"

1A3

2A3

1. Issued for Permit/Tender Aug. 15/14 CRE

ION

3473

ON

R IOOCI

ARCHITECTSOFTA

AT

SA SAug. 15, 2014

01

GWB

GWB

02

03

04

EXP

EXP

#

Architectural Items: Mechanical Items:

Electrical Items:

GWB

SAT

05

07GWB

08

06GWB

THESE DRAWINGS ARE NOT TO BE SCALED.

ALL DRAWINGS, THE DESIGN, AND THE DETAILSTHEREON REMAIN THE PROPERTY OF THEARCHITECT AND ARE NOT TO BE ALTERED,RE-USED OR REPRODUCED WITHOUT THEARCHITECT'S EXPRESS WRITTEN CONSENT.

THE CONTRACTOR MUST FIELD VERIFY ALLDIMENSIONS AND MUST CONFIRM & CORRELATEALL DETAILS WITHIN THE FULL DRAWINGPACKAGE BEING RESPONSIBLE FOR SAMETHROUGHOUT CONSTRUCTION, REPORTINGANY DISCREPANCIES TO THE ARCHITECT PRIORTO COMMENCING THE RELEVANT WORK

ALL DRAWINGS, DETAILS & SPECIFICATIONSREPRESENTED IN THE DRAWINGS ARE TO BEUSED FOR CONSTRUCTION ONLY WHEN ISSUEDBY THE ARCHITECT AND NOTED ACCORDINGLYIN THE "ISSUE/REVISIONS" BOX HEREON.

C .

1413August 2014

V. PaniciC. Elwell

1/4" = 1'-0"

1A4

2A4

1. Issued for Permit/Tender Aug. 15/14 CRE

ION

3473

ON

R IOOCI

ARCHITECTSOFTA

AT

SA SAug. 15, 2014

A

B

C

D

E

F

G

H

l

2

3

Designation: Product Specification General Location

A1 A2AA B

1

3

2

0'-0" F.F.L.

+ 12'-6" A.F.F.

0'-0" F.F.L.

+ 9'-0" A.F.F.

1 1

22

+ 10'-3" A.F.F.

FIN. FLOOR

+ 5'-0" A.F.F.

+ 1'-5" A.F.F.

A

2

C

D

E

F

G

FIN. FLOOR

+ 7'-3 1/2" A.F.F.

2

A

A

3

H

FIN. FLOOR

+ 7'-3 1/2" A.F.F.

2

B

A

A

A

A

THESE DRAWINGS ARE NOT TO BE SCALED.

ALL DRAWINGS, THE DESIGN, AND THE DETAILSTHEREON REMAIN THE PROPERTY OF THEARCHITECT AND ARE NOT TO BE ALTERED,RE-USED OR REPRODUCED WITHOUT THEARCHITECT'S EXPRESS WRITTEN CONSENT.

THE CONTRACTOR MUST FIELD VERIFY ALLDIMENSIONS AND MUST CONFIRM & CORRELATEALL DETAILS WITHIN THE FULL DRAWINGPACKAGE BEING RESPONSIBLE FOR SAMETHROUGHOUT CONSTRUCTION, REPORTINGANY DISCREPANCIES TO THE ARCHITECT PRIORTO COMMENCING THE RELEVANT WORK

ALL DRAWINGS, DETAILS & SPECIFICATIONSREPRESENTED IN THE DRAWINGS ARE TO BEUSED FOR CONSTRUCTION ONLY WHEN ISSUEDBY THE ARCHITECT AND NOTED ACCORDINGLYIN THE "ISSUE/REVISIONS" BOX HEREON.

C .

1413August 2014

V. PaniciC. Elwell

1/2" = 1'-0"

ELEVATIONS: CHAPEL 1 3ELEVATION: GYM STORAGE2

MILLWORK SECTION @ GYM OPEN STORAGEA2MILLWORK SECTION @ PHYS. ED. BASKET STORAGEA1 MILLWORK SECTION @ TYP. CHANGE ROOM BENCH/SHELFB1

1. Issued for Permit/Tender Aug. 15/14 CRE

I ON

3473

ON

R IOOCI

ARCHITECTSOFTA

AT

SA SAug. 15, 2014

FIN. FLOOR01 02

FIN. FLOOR

A

FIN. FLOOR

B A C DB

GLASS GLASS

FRAMELOCATION

NO. FROM TO MATERIAL JAMBELEV. FINISH FIRE RATINGSIZE SWING

DOOR

MATERIAL ELEV. FINISH FIRE RATING

HARDWARE REMARKS

NO.

SWING GLASS NO.

DOORLOCATION

NO. FROM TO MATERIAL JAMBELEV. FINISH FIRE RATINGSIZE

FRAME

MATERIAL ELEV. FINISH FIRE RATING GLASS

HARDWARE SCHEDULE

THESE DRAWINGS ARE NOT TO BE SCALED.

ALL DRAWINGS, THE DESIGN, AND THE DETAILSTHEREON REMAIN THE PROPERTY OF THEARCHITECT AND ARE NOT TO BE ALTERED,RE-USED OR REPRODUCED WITHOUT THEARCHITECT'S EXPRESS WRITTEN CONSENT.

THE CONTRACTOR MUST FIELD VERIFY ALLDIMENSIONS AND MUST CONFIRM & CORRELATEALL DETAILS WITHIN THE FULL DRAWINGPACKAGE BEING RESPONSIBLE FOR SAMETHROUGHOUT CONSTRUCTION, REPORTINGANY DISCREPANCIES TO THE ARCHITECT PRIORTO COMMENCING THE RELEVANT WORK

ALL DRAWINGS, DETAILS & SPECIFICATIONSREPRESENTED IN THE DRAWINGS ARE TO BEUSED FOR CONSTRUCTION ONLY WHEN ISSUEDBY THE ARCHITECT AND NOTED ACCORDINGLYIN THE "ISSUE/REVISIONS" BOX HEREON.

C .

1413August 2014

V. PaniciC. Elwell

As Noted

2 REQ 2 REQ 2 REQ

1. Issued for Permit/Tender Aug. 15/14 CRE

W1

W2

2 REQ

ROOM FLOORS WALLS CEILING MILLWORK GENERAL REMARKSNO. NAME MATERIAL FINISH BASE MATERIAL FINISH MATERIAL FINISH HEIGHT NO.FLOORING NOTES WALL NOTES CEILING NOTES

I ON

3473

ON

R IOOCI

ARCHITECTSOFTA

AT

SA SAug. 15, 2014

Recommended