Thermal Energy Meter - Belimo...BACnet, Modbus, M-Bus or analog Energy optimization through data...

Preview:

Citation preview

A New Era of Energy Management

Thermal Energy Meter

Data transparency without sacrificing occupant comfort

Holistic view of system

Easy to target improvement

Energy Management in Buildings is Evolving

Zero insight Inefficientprocesses

The old world

Zero insight Inefficient processes

The old world

Gateway

00020.02

00020.02 00020.02

20 years ago

Complex, difficult to

understand system

High laborand time cost

Gateway

00020.02

00020.02 00020.02

20 years ago

Complex, difficult to

understand system

High laborand time cost

The FUTURE of energy management

Different Types of Meter Solutions

3

Ultrasonic(Transit Time)

Turbine/Paddle Wheel (Mechanical Insert)

Electro-Magnetic

Differential Pressure

VortexCoriolis

Standard Ultrasonic ++ + - +Vortex + - - +Coriolis (Mass) ++ ++ ++ -- Industrial

Laboratories

Magnetic ++ + + +BelimoUltrasonic ++ ++ +++ + ½” – 6”

Meter Technologies

4

Robust Accuracy Glycol Cost Remark

Diff. Pressure + - - -Turbine Wheel - - - ++

Optimized for HVAC

applications

Where are Thermal Energy Meters Used?

Commercial Buildings Medical CentersUniversities/ Schools

Solar Thermal5

Shopping Malls Geothermal

Thermal Energy Meter

6

Accurate & reliable BTU measurement of hydronic heating and cooling systems

Seamless integration to BMS Equipped for remote IoT-based

platforms to effectively allocate heating and cooling costs

Meets requirements of EN1434 Glycol monitoring and compensation Belimo quality

Product Design

7

External Temperature Sensor

Logic Module

Sensor Module

Internal Temperature Sensor

Flow Body

Customer Benefits

Consulting Engineer High quality metering Proves system designs Attract clients with profile projects

Seamless integration viaBACnet, Modbus, M-Bus or analog

Energy optimization through data transparency

Simple NFC commissioning

Controls Contractor Reliable operation from system monitoring

Energy savings with glycol monitoring Measurement and logging of energy data for

tenant billing

End User

RethinkThermal Energy Management

Customer Benefits

Facility Manger

Reliable performance and operation Notification of operational errors Belimo Cloud provides

remote configuration and data

Cloud API for integration with otherbuilding components

Additional savings from glycol monitoring and compensation

13 month data logger provides baseline and performance verification

ESCO Measurement and logging of energy data, ready

for tenant billing Cloud API to integrate to specific billing platform Glycol monitoring provides differentiation

Sub Metering Company

RethinkThermal Energy Management

Features and Benefits

Configuration and Information at Your Fingertips

11

Easily configure with Belimo assistant app

Generate NIST calibration certificate on demand

Produce commissioning report confirming settings and operation.

Display flow, energy, and operational parameters

Seamless Integration

12

• BACnet IP• BACnet MS/TP

• Modbus TCP/IP• Modbus RTU

Analog Feedback

0…10V 0.5…10V 2…10V User Defined Range

Sensor Input

Active Volt Passive Switch

On Board User Interface

13

Overview of operation

Customizable name and location in building

User & password administration

13 month data logger

Total volume & energy

Easily set parameters

PoE Power Over Ethernet

Single ethernet cable provides robust data and power

Reduced installation cost eliminating transformer and wiring

Simplifies installation and commissioning

Only meter and valve on the market with this capability

14

IoT Ready

Expanded Integration API integration to metering platforms or 3rd party applications

Belimo Cloud integrationRemote meter reading and configuration via the Belimo Cloud

Remotes ServicesReal time access to calibration certificate, commissioning report

Belimo IoT Products & the Eco-System

16

Belimo Cloud User Interface

17

Graphical user Interface Live trended data Health status Overview of operation

LiquidFlow

Acoustic Mirror

Tem

pera

ture

Sens

or

Emitt

er/ R

ecei

ver (

A)

Emitt

er/ R

ecei

ver

(B)

18

Belimo Ultrasonic Technology

Effect of Glycol Compensation: TRUE Accuracy

19

23°F

77°F

194°F

23°F

77°F

194°F[g/min]

Effect of Glycol Compensation: TRUE Accuracy

20

[g/min]

23°F

77°F

194°F

Belimo’s In-House Ultrasonic Meter Calibration

• Every meter is individually wet calibrated• Multi-point calibration• Ensures repeatability and accuracy

21

NIST Traceable Certificates

22

Product Range ½” thru 2”

23

Energy Meter GlycolGlycol monitoring & compensation

Energy Meter MIDCertified EN1434/MID European Measurements Instruments Directive

½”, ¾”, 1”, 1¼”, 1½”, 2”

OutdoorNEMA 4X

Specifications

24

Attribute ValueFluid Chilled or hot water up to 60% glycol

Fluid Temperature Range 4...+250°F [‐5...+120°C]Output Signal 0...5 V (0...10 V) 2...10 VFlow Housing Forged brass nickel platedInlet Length Inlet: 5X Nominal Pipe Size, Outlet zero limitation

Body Pressure Rating 360 psiFitting/Connection  NPT Female

 Measurement Tolerance ± 2% of rate Measurement Repeatability ± 0.5%

Flows 6.6 to 100GPM

Ease of Doing Business

One model per DN size inclusive of all features

Delivery in 2 to 3 days Dedicated Belimo sales team Award winning technical support team Proven quality and technology 5 year warranty

25

Key Take Away Points

1. Products meet the most stringent standards in the world EN1434/CSA C900/MID proving credibility.

2. Simple to order, integrate, commission, and operate.

3. Robust solution built on proven Belimo sensor technology providing precision and reliability.

26

Recommended