Specificiations
Sizes
1/2 STANDARD MODEL
Lid (Perforated) Lid (Perforated) Safety Lid Safety Lid
Box (Non Perforated) Box (Perforated) Box (Non Perforated) Box (Perforated)
h =10
0 m
m
xxxx
xxxx
TK6-500 TK6-530 TK6-640 TK6-670
TK6-501 TK6-531 TK6-641 TK6-671
TK6-502 TK6-532 TK6-642 TK6-672
TK6-503 TK6-533 TK6-643 TK6-673
TK6-504 TK6-534 TK6-644 TK6-674
TK6-505 TK6-535 TK6-645 TK6-675
h =13
5 m
m
xxxx
xxxx
TK6-506 TK6-536 TK6-646 TK6-676
TK6-507 TK6-537 TK6-647 TK6-677
TK6-508 TK6-538 TK6-648 TK6-678
TK6-509 TK6-539 TK6-649 TK6-679
TK6-510 TK6-540 TK6-650 TK6-680
TK6-511 TK6-541 TK6-651 TK6-681
h =15
0 m
m
xxxx
xxxx
TK6-512 TK6-542 TK6-652 TK6-682
TK6-513 TK6-543 TK6-653 TK6-683
TK6-514 TK6-544 TK6-654 TK6-684
TK6-515 TK6-545 TK6-655 TK6-685
TK6-516 TK6-546 TK6-656 TK6-686
TK6-517 TK6-547 TK6-657 TK6-687
h =20
0 m
m
xxxx
xxxx
TK6-518 TK6-548 TK6-658 TK6-688
TK6-519 TK6-549 TK6-659 TK6-689
TK6-520 TK6-550 TK6-660 TK6-690
TK6-521 TK6-551 TK6-661 TK6-691
TK6-522 TK6-552 TK6-662 TK6-692
TK6-523 TK6-553 TK6-663 TK6-693
h =26
0 m
m xxxx
xxxx
TK6-524 TK6-554 TK6-664 TK6-694
TK6-525 TK6-555 TK6-665 TK6-695
TK6-526 TK6-556 TK6-666 TK6-696
TK6-527 TK6-557 TK6-667 TK6-697
TK6-528 TK6-558 TK6-668 TK6-698
TK6-529 TK6-559 TK6-669 TK6-699
Ps: All container measurements cover the outer size of the lids.
xxxx
xxxx
285 mm280 mm
h
STERILE CONTAINER SYSTEMS Standard Model
22
code color weightTK6-630
0.75 kg
TK6-631
TK6-632
TK6-633
TK6-634
TK6-635
code color weightTK6-620
0.62 kg
TK6-621
TK6-622
TK6-623
TK6-624
TK6-625
code color weightTK6-700
0.60 kg
TK6-701
TK6-702
TK6-703
TK6-704
TK6-705
PERFORATED LIDS SAFETY LIDSREMOVAL LIDS (non perforated)
BOX (perforated)
BOX (non perforated)
code outside dimension inside dimension weight
TK6-600 306 x 272 h=100 mm 253 x 258 h=83 mm 1.58 kg
TK6-601 306 x 272 h=116 mm 253 x 258 h=101 mm 1.74 kg
TK6-602 306 x 272 h=138 mm 253 x 258 h=122 mm 1.85 kg
TK6-603 306 x 272 h=190 mm 253 x 258 h=173 mm 2.02 kg
TK6-604 306 x 272 h=235 mm 253 x 258 h=218 mm 2.30 kg
code outside dimension inside dimension weight
TK6-605 306 x 272 h=100 mm 253 x 258 h=94 mm 1.22 kg
TK6-606 306 x 272 h=116 mm 253 x 258 h=112 mm 1.38 kg
TK6-607 306 x 272 h=138 mm 253 x 258 h=133 mm 1.49 kg
TK6-608 306 x 272 h=190 mm 253 x 258 h=184 mm 1.67 kg
TK6-609 306 x 272 h=235 mm 253 x 258 h=230 mm 1.94 kg
xxxx
xxxx
272 mm
253 mm
h
306 mm
h
306 mm
h
253 mm
h
xxxx
xxxx
272 mm
outside dimension
outside dimension
outside dimension
outside dimension
inside dimension
inside dimension
258 mm (inside dimension)
258 mm (inside dimension)
STERILE CONTAINER SYSTEMSStandard Model
23
BASKET MADE FROM STAINLESS STEEL WIRE MESH
WIRE BASKET WITH PERFORATED METAL PLATE
WIRE BASKET
WIRE BASKET
WIRE BASKET WITH LID
WIRE BASKET WITH LID
ACCE
SSOR
IES
(for 1
/2 Mo
del)
code outside dimensionTK2-490 255 x 250 x h=30 mmTK2-491 255 x 250 x h=50 mmTK2-492 255 x 250 x h=70 mmTK2-493 255 x 250 x h=100 mm
code outside dimensionTK3-1040 255 x 250 h=35 mmTK3-1041 255 x 250 h=55 mmTK3-1042 255 x 250 h=75 mmTK3-1043 255 x 250 h=105 mm
TK3-1045 ONLY LID, for baskets
code outside dimensionTK2-491 P 255 x 250 x h=50 mmTK2-492 P 255 x 250 x h=70 mmTK2-493 P 255 x 250 x h=100 mm
code outside dimensionTK3-1041 P 255 x 250 x h=55 mmTK3-1042 P 255 x 250 x h=75 mmTK3-1043 P 255 x 250 x h=105 mm
TK3-1045 P ONLY LID, for baskets
h
h
h
h
STERILE CONTAINER SYSTEMS Standard Model
24
BASKET MADE FROM STAINLESS STEEL SHEET
BASKET (with stand)
IDENTIFICATION (aluminium)
code colorTK2-560TK2-561TK2-562TK2-563TK2-564TK2-565
code colorTK2-570TK2-571TK2-572TK2-573TK2-574TK2-575
Grey coloured recommended for use in Sterrad.Color fading By effect of Hydrogen Peroxide Gas Plasma on other colors.
Coloured identification labels Engraved to your specification
ACCE
SSOR
IES
(for 1
/2 Mo
del)
LABEL HOLDER LABELS
code heightTK3-767 20 mm
code heightTK3-768 10 mm
STAND STAND
code outside dimension
Box and Lid TK3-732 244 x 253 h=43 mm
h
TK3-733 244 x 253 h=63 mmTK3-734 244 x 253 h=83 mmTK3-735 244 x 253 h=113 mm
Box TK3-752 244 x 253 h=40 mm
hTK3-753 244 x 253 h=60 mmTK3-754 244 x 253 h=80 mmTK3-755 244 x 253 h=110 mm
LidTK3-763 ONLY LID, for baskets
STERILE CONTAINER SYSTEMSStandard Model
25
ACCE
SSOR
IES
(for 1
/2 Mo
del)
Thoracotomy
Bas�c Set
Thoracotomy
Bas�c Set
Thoracotomy
Bas�c Set
DIVIDERS
RACK (for kerrison)
ALUMINIUM BASKET (with lid) ALUMINIUM BASKET (with lid) ALUMINIUM BASKET (with lid)
SILICONE MAT SILICONE MESH MAT
PAPER FILTER TEFLON FILTER
IDENTIFICATION LABELS (aluminium)
SECURITY SEAL (blue)
SECURITY SEAL (red)
SECURITY SEAL (blue)
SECURITY SEAL (red)
SECURITY SEAL (blue)
SECURITY SEAL (red)
DISPOSAL STAMP
WIRE BASE
DRAPE RETAINER DRAPE RETAINER
LABELS (paper) LABELS (paper)
LABEL HOLDER
SILICONE HANDLE
FILTER DISPENSER
TK2-483255 x 245 x 130 mmTK2-484255 x 245 x 180 mm
TK2-521250 x 235 mm
TK2-482255 x 255 x 30 mm
TK3-481255 x 255 x 30 mm
TK3-1119245 x 130 x 55 mm
TK3-1120245 x 130 x 70 mm
TK3-1121245 x 130 x 105 mm
TK2-480255 x 255 mm
TK3-1094225 x 245 x 160 mm• Holds 10 kerrison punches• Fits into a 1/2 and 1/1 size • 20 cm deep container• Wire basket 1/2 50 mm• Wire basket 1/1 50 mm• Container 1/2 200 mm• Container 1/1 200 mm
TK2-673100 pcs. With indicator.
For small size and special containers
TK2-663100 pcs. with indicator.made of plastic
TK2-662100 pcs. with indicator.made of plastic
TK2-71740 x 35 x 9 mmRequested number or letter must be informed during the order.
TK2-71650 x 35 x 13 mmHolder for identification labels
TK2-661100 pcs. with number.made of plastic
TK2-665100 pcs. with number.made of plastic
( - )
( - )
TK2-664100 pcs. made of plastic
TK2-660100 pcs. made of plastic
TK2-672100 pcs. With indicator.
For full and Half size containers
TK2-700TK2-701TK2-702TK2-703TK2-704TK2-705
TK2-710TK2-711TK2-712TK2-713TK2-714TK2-715
TK2-730TK2-740Single use 100 pcs with indicator. Tesuart mark.• Diameter: 185 mm
TK2-742Number of sterilization cycle > 2000• Diameter: 194 mm
TK2-530250 x 250 mm
STERILE CONTAINER SYSTEMS Standard Model
26
Modular Auto Lock Mechanism
STERILE CONTAINER SYSTEMS
TÜRK PATENT ENSTİTÜSÜ - - - - - - - - - - - - - - - - - - -No: a2012 00715DEUTSCHES PATENT - - - - - - - - - - - - - - - - - - - - Nr. 20 2013 100 251.8
codeTK1-900 (2 Pcs)
This system has been developed in accordance with the requirements of sterilization to be used in a steam autoclave for our container systems. Auto lock is a system designed in reusable property instead of disposable plastic products that are used as security locks in containers. The system has been tested in our own facilities 5000 cycles and has suc-cessfully passed al tests. Minimum expected life of the system is 5000 sterilizations. During this time system is usable without the need for any maintenance or service.
HOW DOES AUTO LOCK MECHANISM WORK?
The average temperature in the autoclave during steril-ization is at the level of 135 ° C degrees.
As the temperature in the autoclave begins to rise above 100 degrees, automatic locking mechanism located on the box is activated. When the mechanism is activated, the red movable locking shaft in it is going forward (Picture 1). When the movable locking shaft is going forward, it blocks the locking mechanism in lid and so it prevents uncontrolled opening of the lid.
WARNING: It’s possible to move the movable shaft with only the effect of temperature. It’s not possible under normal conditions
to activate (to be brought into locked position) lock mechanism.
GENERAL INFORMATION ABOUT MODULAR AUTO LOCK MECHANISM
Picture 1 (Closed position)
WHAT IS AUTO LOCK MECHANISM?
Auto lock mechanism is a heat-sensitive automatic locking system developed in order to ease sterilization control by R&D department.
Modular auto lock system designed to be usable with different container systems which are belongs to different brands like shown below.
STERILE CONTAINER SYSTEMS Standard Model
40
WHAT ARE THE ADVANTAGES OF MODULAR AUTO LOCK MECHANISM?
All our container systems with Auto Lock mechanism are designed to be used also with plastic security seal when necessary (Picture 4).
The process of the system becoming inactive is as follow-ing: After sterilization process has been completed and container has been removed from the autoclave, the con-tainer and Auto Lock system are allowed to cool between 5 and 10 minutes. Then the red movable locking shaft is pushed back with the help of fingers (Picture 3). Thus, lid closure of the container ceases to be blocked and comes to opened position.
When the container enters into each sterilization, these processes are repeated in the same manner.
When the user sees that Auto Lock mechanism is activat-ed (Picture 1), he/she can understand that the container has entered to the sterilization process. If Auto lock mech-anism is inactive (Picture 2), it means that this container has been previously opened.
► Because of system being reusable, it is more economi-cal when you compare with plastic security seal usage.
► System is modular, so it can be usable with different brand products. In this reason, so many users can make use of system advantages.
► After the usage of disposable products, plastic mate-rial harms the nature. Because of reusable property of auto lock mechanism and because of recycling raw material inside, system does not harm the nature.
► Disposable products have many disadvantages such as purchasing, storage and inventory tracking. Auto Lock mechanism saves the user from this workload and cost.
► Disposable products must be attached to the (2) container(s) prior to each sterilization and this leads to loss of time for the employees.
► Auto Lock Mechanism removes the difficulties faced during the use of security seals. In breakdown condi-tion, because of product is not fixed on the container, system can be easily serviceable or changeable so container does not needs replacing.
Picture 2 (Open position)
Picture 4 (Plastic security seal)
Picture 3
STERILE CONTAINER SYSTEMSStandard Model
41
Lock mechanism should be in open position for the disas-
sembly process (Picture 2).
It is not possible to make disassembly on closed position
(Picture 1).
When you sure that lock mechanism is on open position,
locking clamp can be removable by pulling backward
through the reverse direction of the locking direction.
Locking clamp should be removed from the groove before assembly.
When you sure that product is snug, locking clamp should be placed through the arrow direction.
Please be sure that locking stamp is forwarded to the end of the clamp groove and it is locked.
Then it should be placed to the container label part as shown picture.
Due to container model that system will be assembled plastic washer should be removed or stay in place.
1
3
2
4
Modular Auto Lock Mechanism
Plastic Washer
locking Clamp
It is not possible to make disassembly
on closed position Closed position Picture 1
ASSEMBLY AND DISASSEMBLY OF MODULAR AUTO LOCK MECHANISM
STERILE CONTAINER SYSTEMS Standard Model
42
Patent Pending
Emulating indicators are used for the load sterilization monitorization while surgical instruments are loading to containers in central sterilization units (cssd). (Picture 2)
During standard container usage it is not possible to see indicator results without opening the lid. When set is decided to use in surgery if result is negative and also if there is no alternative set, surgery is delaying and problems occurs in implementations.
We continue to produce solution for the sterilization management require-ments with our 25 years of experience in medical industry.
For this purpose, we have devel-oped emulating indicator window for the sterile container systems.
Result of the emulating indicator can observed after cycle easily from the window on the container case. In negative conditions, sterilization processes are repeated before send set to usage. By this way waste of time prohibited and it can help to avoid troubles before start.
AIM OF THE WINDOW FOR EMULATING INDICATOR
Picture 2
Picture 1
WINDOW FOR EMULATING INDICATOR
TK2-674 Paper 250 Pcs.
EMULATING INDICATOR
STERILE CONTAINER SYSTEMS Standard Model
44
► Transparent PPSU polymer material is used on window part of the system which is suitable to autoclave. PPSU polymer material has resistance to scoring and impact also it is a special material which has heat resistance up to 330O
► Silicon joint is used between window and box to avoid sterilization risk inside the container and
security is provided %100 by 4 pieces rivet connection.
► All other parts used in the system is manufactured from anodized aluminum and stainless steel.
► Indicator is designed to place the box from two directions. Also there is a spring mechanism to im-mobilize indicator because of the pressure inside the indicator placed sections. This spring mech-anism and the immobilization property from the two side of indicator are provided to use different branded indicators to use in this system together.
Emulating indicator before placing materials to sterilize inside the box for the sterilization purpose is placed inside the box as below. (Picture 3 )
When you placed indicator band inside the box, you should be sure that placed refer-ences and indicator should appears. You should specify the suitable position by recip-rocating motions or rotating reverse the indicator band.
After you placed indicator band fairly, you can start sterilization process by placing materials to sterilize after closing the lid.
1
2
3
USAGE OF WINDOW FOR EMULATING INDICATOR
WINDOW FOR EMULATING INDICATOR
Picture 3
NO RISK...NO RISK...STERILE CONTAINER SYSTEMSStandard Model
45
Recommended