Standard 100 Standard 100 Energy Energy Efficiency in Existing Efficiency in Existing BuildingsBuildings Revision Revision
Michele Friedrich, PEPECI
Portland, OR503-575-4149
mfriedrich@peci.orgwww.peci.org
6/27/2010
Energy for Change™
ANSI/IESNA/ASHRAE Standard 100-2006
6/27/2010Standard 100 Revision Overview
• TITLE: ENERGY EFFICIENCY IN EXISTING BUILDINGS• PURPOSE:
– This standard provides criteria that will result in energy efficiency in existing buildings.
– This standard is directed toward:a. Providing procedures and programs essential to energy efficient operation,
maintenance, management and monitoring;b. Increasing the energy efficiency of the energy-using systems and
components; andc. Upgrading the thermal performance of the building envelope.
• SCOPE: This standard applies to existing buildings, portions of buildings, and building complexes, including the envelope and all systems in the building. This Standard excludes industrial and agricultural processes in buildings for which the energy use targets do not include those processes.
6/27/2010Standard 100 Revision Overview
ANSI/IESNA/ASHRAE Standard 100 Revision Title, Purpose and Scope
June 22, 2010 – 50% draft completeSept 30, 2010 – 1st complete draftDec 7, 2010 – SPC 100 Vote to approve
draft standard for public reviewSpring, 2011 – Standard 100 public review
6/27/2010Standard 100 Revision Overview
ANSI/IESNA/ASHRAE Standard 100 Revision Timeline
ANSI/IESNA/ASHRAE Standard 100 Revision Outline• Title
1. Purpose2. Scope3. Definitions4. Compliance Requirements5. Energy Use Analysis and Target Requirements6. Operation and Maintenance Requirements7. Energy Audit Requirements 8. Implementation and Verification Requirements• References
6/27/2010Standard 100 Revision Overview
Standard 100 Flow Chart
6/27/2010Standard 100 Revision Overview
Compliance RequirementsSection 4
Compliance RequirementsSection 4
Standard 100 Compliance
Standard 100 Compliance
Does Building
Meet Energy Target?Sect. 5
Does Building
Meet Energy Target?Sect. 5
NO
YESIs there a Target for Building type?
Section 5
Is there a Target for Building type?
Section 5
YES
NO
Standard 100 Seek Compliance
Standard 100 Seek Compliance
Implement Mandatory Operations and Maintenance
Section 6
Implement Mandatory Operations and Maintenance
Section 6
Complete Compliance Forms for Buildings with
Targets Section 4
Complete Compliance Forms for Buildings with
Targets Section 4
Complete Compliance Forms for Buildings w/o
TargetsSection 4
Complete Compliance Forms for Buildings w/o
TargetsSection 4
Verify Energy Savings
Section 8
Verify Energy Savings
Section 8
Prioritize, Implement &
Commission EEMsSection 8
Prioritize, Implement &
Commission EEMsSection 8
Verify Energy Savings
Section 8
Verify Energy Savings
Section 8
Prioritize, Implement & Commission
EEMsSection 8
Prioritize, Implement & Commission
EEMsSection 8
Conduct Energy Audit Section 7Conduct Energy Audit Section 7
Conduct Energy Audit Section 7Conduct Energy Audit Section 7
Identify Building Type, Climate Zone and Collect
Energy Use Data, Section 5
Identify Building Type, Climate Zone and Collect
Energy Use Data, Section 5
Building Baselines and Targets• Benchmarks are being compiled from CBECS 2003
for building type and climate zone. • Authority Having Jurisdiction can pick level of
compliance in reference to Benchmark for Target (e.g. Federal Buildings may pick 30% lower).
• Owner to conduct energy use analysis from utility bills to get Baseline Energy Use Intensity (kBTU/ft2-yr).
6/27/2010Standard 100 Revision Overview
Energy Use Benchmarks• Usage per
square foot• Compare
buildings of similar use-type and climatic conditions
6/27/2010Standard 100 Revision Overview
End Use Energy Intensity by Building TypeCBECS 2003
0.0 50.0 100.0 150.0 200.0 250.0 300.0
Education
Food Sales
Food Service
Health Care
(Inpatient)
(Outpatient)
Lodging
Mercantile
(Retail-Other Than Mall)
(Enclosed and Strip Malls)
Off ice
Public Assembly
Public Order and Safety
Religious Worship
Service
Warehouse and Storage
Other
Vacant
Thousand Btu/Square Foot
Space Heating
Cooling
Ventilation
Water Heating
Lighting
Cooking
Refrigeration
Office Equipment
Computers
Other
Energy Use TargetsCompare buildings of similar use-type and climatic conditions using statistical distribution
6/27/2010Standard 100 Revision Overview
Energy Use Analysis
6/27/2010Standard 100 Revision Overview
Control Volume around Building and Building Systems
Site Energy Used “to Keep It Simple.”
On-site Power Generation Included “to Keep It Simple.”
Building Baselines and Targets• If building type is listed in Target List,
compare Baseline to Target. – If Baseline <= Target, requirement of Sec. 5 met. – If Baseline > Target, must complete Sec 7 & 8.
• If building type not listed in Target list, must complete Sec 7 & 8.
6/27/2010Standard 100 Revision Overview
Questions? Volunteer?Michele FriedrichASHRAE SPC 100 ChairMFriedrich@PECI.org
6/27/2010Standard 100 Revision Overview
Recommended