View
10
Download
0
Category
Preview:
Citation preview
Single Phase Inverter, Power Optimizerwith Compact TechnologyInverters: SE1000M, SE1500M, SE2000MPower Optimizer: M2640
solaredge.com
SINGLE PH
ASE INVERTERS,
POW
ER OPTIM
IZER
12-25YEAR
WARRANTY
25YEAR
WARRANTY
Suitable for homes with limited roof space, social housing projects, or for meeting minimum sustainability requirements
Cost-effective solution for residential systems of 4-8 modules
Each of the four power optimizer inputs supports one or two 60-cell modules, or one 72/96-cell modules
Extremely compact, lightweight, and easy to install
IP65 rated inverter — suitable for indoor or outdoor installation
Power optimizer and inverter designed to work exclusively with each other and are ordered with a single part number and supplied in a single box
Optional communication option for maximum cost effectiveness
Single Phase Inverter, Power Optimizerwith Compact Technology
(1) Wi-Fi connectivity requires an external antenna. For more information refer to: https://www.solaredge.com/sites/default/files/se-wifi-zigbee-antenna-datasheet.pdf(2) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
INVERTER SPECIFICATIONS:SE1000M SE1500M SE2000M UNIT
OUTPUTMaximum AC Power Output 1000 1500 2000 VA
AC Output Voltage (nominal) 220 / 230 Vac
AC Output Voltage Range 184 - 264.5 Vac
AC Frequency (nominal) 50 / 60 ± 5 Hz
Maximum Continuous Output Current 5 7 9.5 A
INPUTMaximum DC Power 1350 2025 2640 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage 500 Vdc
Operating Voltage 75 - 480 Vdc
Maximum Input Current 11 Adc
Maximum Inverter Efficiency 97 %
European Weighted Efficiency 95.7 96.5 97 %
ADDITIONAL FEATURES
Supported Communication InterfacesBasic: No Communication Interfaces
Extended: RS485 Interface, communication to SolarEdge monitoring platform via built-in Ethernet or Wi-Fi(1) connectivity, or additional options purchased separately such as ZigBee or GSM plug-ins
Smart Energy ManagementBasic: No Smart Energy Management
Extended: Export Limitation, Home Energy Management
STANDARD COMPLIANCESafety IEC-62103 (EN50178), IEC-62109
Grid Connection Standards VDE-AR-N-4105, VDE 0126-1-1, AS-4777, RD-1663, DK5940
Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part 15 class B
RoHS Yes
INSTALLATION SPECIFICATIONSDimensions (H x W x D) 340 x 239 x 127 mm
Noise < 25 dBA
Weight 6 kg
Cooling Natural Convection
Operating Temperature Range -40 to +60(2) C
Protection Rating IP65 - Outdoor and Indoor
Inverters: SE1000M, SE1500M, SE2000MPower Optimizer: M2640
Single Phase Inverter, Power Optimizerwith Compact Technology
POWER OPTIMIZER SPECIFICATIONS:M2640 (For 4-8 60-cell modules or 4 72-cell / 96-cell modules) UNIT
INPUTNumber of Inputs 4
Number of MPP Trackers 4 (one per input)
Rated DC Power per Input(1) 660 W
Absolute Maximum Input Voltage per Input(Voc at lowest temperature) 96 Vdc
MPPT per Input Operating Range 12.5 - 80 Vdc
Maximum Short Circuit Current per Input (Isc) 10.5 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.8 %
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)Maximum Output Current 10.5 Adc
Maximum Output Voltage 340 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTEDFROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)Safety Output Voltage per Power Optimizer 10 ± 1 Vdc
INSTALLATION SPECIFICATIONSMaximum Allowed System Voltage 600 Vdc
Dimensions (H x W x D) 152 x 211 x 60 mm
Weight (including cables) 1.5 kg
Input Connector 4 x MC4 Pairs
Output Connector 1 x MC4 Pair
Operating Temperature Range -40 to +85 C
Protection Rating IP68
(1) Rated STC power of the module. Module of up to +5% power tolerance allowed.
SE1000M SE1500M SE2000M UNITPV SYSTEM DESIGNNumber of M2640 per Inverter 1
Maximum DC System Power 1350 2025 2640 WDC
© SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 02/2019/V01/ENG ROW. Subject to change without notice.
Inverters: SE1000M, SE1500M, SE2000MPower Optimizer: M2640
INVERTERS
solaredge.com
Optimized installation with HD-Wave technology
Specifically designed to work with power optimizers
Outdoor and indoor installation
Fixed voltage inverter for longer strings
Advanced safety feature - integrated arc faultprotection
Quick and easy inverter commissioning directlyfrom a smartphone using the SolarEdge SetApp
Record-breaking efficiency
Extremely small, lightweight and easy to install
High reliability
Built-in module-level monitoring
Single Phase Inverterwith HD-Wave Technology SE2200H, SE3000H, SE3500H, SE3680H,SE4000H, SE5000H, SE6000H
12-25YEAR
WARRANTY
SE2200H SE3000H SE3500H SE3680H SE4000H SE5000H SE6000HAPPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4
OUTPUT Rated AC Power Output 2200 3000 3500 3680 4000 5000(1) 6000 VA
Maximum AC Power Output 2200 3000 3500 3680 4000 5000(1) 6000 VA
AC Output Voltage (Nominal) 220/230 Vac
AC Output Voltage Range 184 - 264.5 Vac
AC Frequency (Nominal) 50/60 ± 5 Hz
Maximum Continuous Output Current 10 14 16 16 18.5 23 27.5 A
Total Harmonic Distortion (THD) <3 %
Power Factor 1, adjustable -0.9 to 0.9
Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds Yes
INPUT Maximum DC Power 3400 4650 5425 5700 6200 7750(2) 9300 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage 480 Vdc
Nominal DC Input Voltage 380 Vdc
Maximum Input Current 6.5 9 10 10.5 11.5 13.5 16.5 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600kΩ Sensitivity per Unit
Maximum Inverter Efficiency 99.2 %
European Weighted Efficiency 98.3 98.8 99 %
Nighttime Power Consumption < 2.5 W
ADDITIONAL FEATURESSupported Communication Interfaces RS485, Ethernet, Wi-Fi (optional), Cellular (optional), ZigBee (optional)
Smart Energy Management Export Limitation
Inverter Commissioning With the SetApp mobile application using built in Wi-Fi station for local connection
Arc Fault Protection Integrated, User Configurable (According to UL1699B)
STANDARD COMPLIANCE Safety IEC-62109-1/2
Grid Connection Standards IEC61727, IEC62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE_C_15-712, G98,G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1
Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC Part 15 Class B
INSTALLATION SPECIFICATIONS AC Output - Supported Cable Diameter 9-16 mm
AC - Supported Wire Cross Section 1-13 mm2
DC Input 1 x MC4 2 x MC4 pair
Dimensions (H x W x D) 280 x 370 x 142 mm
Noise < 25 dBA
Weight 7.8 9 10.6 kg
Cooling Natural Convection
Operating Temperature Range -40 to +60(3) ˚C
Protection Rating IP65 — Outdoor and Indoor
(1) 4600VA in Germany (2) 7130VA in Germany(3) Full power up to at least 50˚C / 122˚F. For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
Single Phase Inverterwith HD-Wave TechnologySE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H
© SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 2/2020/V01/ENG ROW Linux. Subject to change without notice.
INVERTERS
Three Phase InverterSE3K - SE10K
solaredge.com
Specifically designed to work with power optimizers
Noise level suitable for residential environments – No external fan
Internet connection through Ethernet or Wireless (Wi-Fi, ZigBee Gateway, Cellular)
Small, lightest in its class, and easy to install Fixed voltage inverter for longer strings
Superior efficiency (98%) IP65 – Outdoor and indoor installation
Built-in module-level monitoring
Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp
Smart Energy Management control
12-25YEAR
WARRANTY
Three Phase InverterSE3K-SE10K(1)
© SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 02/2020/V01/ENG ROW Subject to change without notice.
SE3K(2)(3) SE4K(2) SE5K SE6K(2) SE7K SE8K SE9K SE10K UNITSApplicable to inverters with part number SEXXK-XXXTXBXX4
OUTPUTRated AC Power Output 3000 4000 5000 6000 7000 8000 9000 10000 VA
Maximum AC Power Output 3000 4000 5000 6000 7000 8000 9000 10000 VAAC Output Voltage - Line to Line /Line to Neutral (Nominal) 380 / 220 ; 400 / 230 Vac
AC Output Voltage - Line to Neutral Range 184 - 264.5 Vac
AC Frequency 50/60 ± 5 HzMaximum Continuous OutputCurrent (per Phase) 5 6.5 8 10 11.5 13 14.5 16 A
Grids Supported - Three Phase 3 / N / PE (WYE with Neutral)Utility Monitoring, Islanding Protection, Configurable Power Factor,Country Configurable Thresholds
Yes
INPUTMaximum DC Power (Module STC) 4050(4) 5400 6750 8100 9450 10800 12150 13500 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage 900 Vdc
Nominal DC Input Voltage 750 Vdc
Maximum Input Current 5 7 8.5 10 12 13.5 15 16.5 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 700kΩ Sensitivity
Maximum Inverter Efficiency 98 %
European Weighted Efficiency 96.7 97.3 97.3 97.3 97.4 97.6 97.5 97.6 %
Nighttime Power Consumption < 2.5 W
ADDITIONAL FEATURESSupported Communication Interfaces(5) RS485, Ethernet, ZigBee (optional), Wi-Fi (requires antenna)(6), Cellular (optional)
Smart Energy Management Export Limitation, Home Energy Management (Device Control)
Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi access point for local connection
STANDARD COMPLIANCESafety IEC-62103 (EN50178), IEC-62109
Grid Connection Standards(7) VDE 0126-1-1, VDE-AR-N-4105, AS-4777, G83 / G59
Emissions IEC61000-6-2, IEC61000-6-3 , IEC61000-3-11, IEC61000-3-12, FCC part15 class B
RoHS Yes
INSTALLATION SPECIFICATIONSAC Output Cable Gland - diameter 15-21 mm
DC Input 2 MC4 pairs
Dimensions (HxWxD) 540 x 315 x 191 mm
Weight 16.4 kg
Operating Temperature Range -40 to +60(8) ˚C
Cooling Internal Fan
Noise < 40 dBA
Protection Rating IP65 - Outdoor and Indoor
Mounting Bracket Provided(1) For higher power models refer to: https://www.solaredge.com/sites/default/files/se-three-phase-inverter-extended-power-datasheet.pdf(2) Available in some countries; refer to Certifications category in Downloads page: http://www.solaredge.com/groups/support/downloads(3) SE3K-RW010BNN4 is dedicated for connection of exactly 10 P404/P405/P485/P505 optimizers.(4) Maximum allowed DC power is 3700W with SE3K-RW010BNN4(5) Refer to Datasheets -> Communications category in Downloads page for specifications of optional communication options: http://www.solaredge.com/groups/support/downloads(6) Wi-Fi connectivity requires an external antenna. For more information refer to: https://www.solaredge.com/sites/default/files/se-wifi-zigbee-antenna-datasheet.pdf (7) For all standards refer to Certifications category in Downloads page: http://www.solaredge.com/groups/support/downloads(8) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
INVERTERS
Three Phase InvertersFor Delta Grids (Norway, Taiwan & Philippines)SE12.5K - SE27.6K
solaredge.com
Specifically designed to work with power optimizers
Superior efficiency (98%)
Internet connection through Ethernet or Wireless
IP65 – Outdoor and indoor installation
Fixed voltage inverter, DC/AC conversion only
Optional integrated DC Safety Unit - eliminates the need for external DC isolators
Optional DC surge protection and DC fuses
Advanced safety features - integrated arc fault protection and optional rapid shutdownfuses
Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp
Small, lightest in its class, and easy to install
Built-in module-level monitoring
12-20YEAR
WARRANTY
SE12.5K - SE27.6K
© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Ltd. All other trademarks mentioned herein are trademarks of their respective owners. Date: 11/2019/V02/ENG ROW. Subject to change without notice.
Three Phase Inverters for Delta Grids
(Norway, Taiwan & Philippines)
SE12.5K SE15K SE16K SE17K SE25K SE27.6KApplicable to inverters with part number SEXXK-XXXXXBXX4OUTPUT Rated AC Power Output 7200 8700 9200 10000 14500 16000 VAMaximum AC Power Output 7200 8700 9200 10000 14500 16000 VAAC Output Voltage - Line to Line / Line to PE 220 / 127 ; 230 / 133 VacAC Output Voltage - Line to Line Range 184 - 264.5 VacAC Frequency 50/60 ± 5 HzMaximum Continuous Output Current (per Phase) 20 23 25.5 26 38 40 AResidual Current Detector / Residual Current Step Detector 300 / 30 mA
Grids Supported - Three Phase 3 Lines / PE (Delta; corner grounding not supported)Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds Yes
THD < 3 %
INPUT Maximum DC Power (Module STC) 9720 11745 12420 13500 19575 21600 %Transformer-less, Ungrounded Yes Maximum Input Voltage 600 VdcNominal DC Input Voltage 400 Vdc Maximum Input Current 19 22.5 24 26 37.5 40 AdcReverse-Polarity Protection Yes Ground-Fault Isolation Detection 700kΩ Sensitivity 350kΩ Sensitivity(1) Maximum Inverter Efficiency 98 98.3 %European Weighted Efficiency 97.7 97.6 97.7 97.7 98 %Nighttime Power Consumption < 2.5 < 4 W
ADDITIONAL FEATURESSupported Communication Interfaces(2) RS485, Ethernet, Wi-Fi (requires antenna(3)), ZigBee (optional), Cellular (optional)Inverter Comissioning With the SetApp mobile application using built-in Wi-Fi access point for local connectionRapid Shutdown Optional(4) (Automatic upon AC Grid Disconnect)Arc Fault Protection Integrated, User Configurable (According to UL1699B)Smart Energy Management Export limitation RS485 Surge Protection Optional(5)
DC SAFETY UNIT (OPTIONAL)2-pole Disconnection N/A 1000V / 40ADC Surge Protection N/A Type II, field replaceableDC Fuses on Plus & Minus N/A Optional, 20ACompliance N/A UTE-C15-712-1
STANDARD COMPLIANCE Safety IEC-62103 (EN50178), IEC-62109 Grid Connection Standards(6) C10/11, EN50438 Emissions IEC61000-6-2, IEC61000-6-3 , IEC61000-3-11, IEC61000-3-12 RoHS Yes
INSTALLATION SPECIFICATIONS AC Output Cable Gland - diameter 15 - 21 Cable Gland - diameter 18 - 25 mmDC Input 2 MC4 pairs 3 MC4 pairs
DC Input with Safety UnitN/A Gland outer diameter 5 - 10 mmN/A Wire cross section 0.5 - 13.5 mm2
Dimensions (HxWxD) 540 x 315 x 260 mmDimensions with Safety Unit (HxWxD) N/A 775 x 315 x 260 mmWeight 30.7 42.5 kgWeight with Safety Unit N/A 45.5 kgOperating Temperature Range -40 - +60(7) ˚CCooling Fan (user replaceable) Noise < 50 < 55 dBAProtection Rating IP65 - Outdoor and Indoor Mounting Bracket Provided (1) Where permitted by local regulations(2) Refer to Datasheets -> Communications category in Downloads page for specifications of optional communication optons: https://www.solaredge.com/downloads#/(3) Wi-Fi connectivity requires an external antenna. For more information refer to: https://www.solaredge.com/sites/default/files/se-wifi-zigbee-antenna-datasheet.pdf(4) Inverter with rapid shutdown part number: SExxK-RWRxxxxxx ; available for SE25K and SE27.6K(5) Provided with the inverter in India only. For other countries an SPD plug-in can be purchased. Refer to: https://www.solaredge.com/sites/default/files/se_spd_plug_in_for_rs485_3ph_setapp_ds.pdf
(6) For all standards refer to Certifications category in Downloads page: http://www.solaredge.com/groups/support/downloads(7) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
Three Phase Inverter with Synergy TechnologySE50K / SE55K / SE82.8K
solaredge.com
Specifically designed to work with power optimizersEasy two-person installation – each unit mounted separately, equipped with cables for simple connection between units
Balance of System and labor reduction compared to using multiple smaller string inverters
Independent operation of each unit enables higher uptime and easy serviceability
No wasted ground area: wall/rail mounted or horizontally mounted under the modules (10 inclination)
Fixed voltage inverter for superior efficiency (98.3%) and longer strings
Integrated Connection Unit with optional integrated DC Safety Switch – eliminates the need for external DC isolators
Built-in module-level monitoring with Ethernet or cellular GSM
Advanced safety features - integrated arc fault protection and optional rapid shutdown
Built-in RS485 Surge Protection, to better withstand lightning events
INVERTERS12-20
YEARWARRANTY
Three Phase Inverter with Synergy TechnologySE50K / SE55K / SE82.8K
© SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2020. V.01/ENG Subject to change without notice.
(1) Available in some countries. Refer to: https://www.solaredge.com/sites/default/files/se_inverters_supported_countries.pdf(2) 49990 in the UK(3) If an external RCD is required, its trip value must be ≥ 300mA per unit (≥ 600mA for SE50K/SE55K; ≥ 900mA for SE82.8K)(4) Where permitted by local regulations(5) Refer to Datasheets -> Communications category on Downloads page for specifications of optional communication options: http://www.solaredge.com/groups/support/downloads(6) Inverter with rapid shutdown part number: SExxK-RWRxxxxxx; Available for SE55K and SE82.8K(7) For all standards refer to Certifications category on Downloads page: http://www.solaredge.com/groups/support/downloads(8) The DC input type, MC4 or glands, and DC switch depends on the part number ordered. Inverter with glands and DC switch P/N: SExxK-xx0P0BNG4, inverter with glands and without DC switch P/N: SExxKxx 0P0BNA4, inverter with MC4 and with DC switch P/N: SExxK-xx0P0BNU4, inverter with MC4 and without DC switch P/N: SExxK-xx0P0BNY4(9) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
SE50K(1) SE55K SE82.8KOUTPUTRated AC Power Output 50000(2) 55200 82800 VAMaximum AC Power Output 50000(2) 55200 82800 VAAC Output Voltage — Line to Line / Line to Neutral (Nominal) 380/220 ; 400/230 VacAC Output Voltage — Line to Line Range / Line to Neutral Range 304 - 437 / 176 - 253 ; 320 - 460 /184 - 264.5 Vac
AC Frequency 50/60 ± 5 HzMaximum Continuous OutputCurrent (per Phase) @Vac,nom 76 80 120 A
Grids Supported — Three Phase 3 / N / PE (WYE with Neutral) VMaximum Residual Current Injection 250 per unit(3) mAUtility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds Yes
INPUTMaximum DC Power (Module STC),Inverter / Unit 67500 / 33750 74520 / 37260 111750 / 37250 W
Transformer-less, Ungrounded YesMaximum Input Voltage 1000 VdcNominal DC Input Voltage 750 VdcMaximum Input Current 2 x 37 2 x 40 3 x 40 AdcReverse-Polarity Protection YesGround-Fault Isolation Detection 350kΩ Sensitivity per Unit (4)
Maximum Inverter Efficiency 98.3 %European Weighted Efficiency 98 %Nighttime Power Consumption < 12 W
ADDITIONAL FEATURESSupported Communication Interfaces(5) RS485, Ethernet, GSM plug-in (optional)RS485 Surge Protection Built-inRapid Shutdown Optional(6) (Automatic upon AC Grid Disconnect)
CONNECTION UNITDC Disconnect (optional) 1000V / 2 x 40A 1000V / 3 x 40A
STANDARD COMPLIANCESafety IEC-62109, AS3100Grid Connection Standards(7) VDE-AR-N-4105, G99, AS-4777,EN 50438 , CEI-021,VDE 0126-1-1, CEI-016, BDEWEmissions IEC61000-6-2, IEC61000-6-3 , IEC61000-3-11, IEC61000-3-12RoHS Yes
INSTALLATION SPECIFICATIONSNumber of Units 2 3
AC Output Cable Cable gland — diameter 22-32; PE gland diameter 10-16 Cable gland — diameter 30-38; PE gland diameter 10-16 mm
DC Input(8) 6 strings, 4-10mm2 DC wire, gland outer diameter 5-10mm / 3 MC4 pairs per unit
9 strings, 4-10mm2 DC wire, gland outer diameter 5-10mm / 3 MC4 pairs per unit
AC Output Wire Aluminum or Copper; L, N: Up to 70, PE: Up to 35 Aluminum or Copper; L, N: Up to 95, PE: Up to 50 mm2
Dimensions (H x W x D) Primary Unit: 940 x 315 x 260; Secondary Unit: 540 x 315 x 260 mmWeight Primary Unit: 48; Secondary Unit: 45 kgOperating Temperature Range -40 to +60(9) ˚CCooling Fan (user replaceable)Noise < 60 dBAProtection Rating IP65 — Outdoor and IndoorMounting Bracket provided
Recommended