SENSEI Series Features Level 1...Turbo Fan 2” Ring and Cap design 2” PVC/CPVC/PP = 65 ft. 2X4”...

Preview:

Citation preview

SENSEI Series Features

• Designed for North American Needs

• Combines Rinnai Global Technologies and Best Practices

• Same Rinnai Quality and Reliability

• Focused on 3 ideals to Captivate Customers:

1. Installation Ease

2. Operational Performance

3. Serviceability

A new combustion design combines several components that work in harmony for enhanced system features. These allow for:

• Easier and more flexible installations• In more locations• With better operational performance

All of the key components are designed and manufactured by Rinnai – Vertically integrated to ensure Rinnai quality

SENSEI Series Features

Installation Ease and Performance

Turbo Fan2” Ring and Cap design2” PVC/CPVC/PP = 65 ft.2X4” Next gen concentric vent = 65 ft.

3” PVC/CPVC/PP = 150 ft.3X5” concentric = 150ft.Numerous common vent options

Zero governor gas valveIs more forgiving with ½ gas line and/or low gas pressure supply situations

Switching Venturi valveMixes gas and air for up to 13 to 1 turn down

ratios

SENSEI Series Features

1. Installation Ease - To save time and money 2. Performance – For Customer Satisfaction

The Most Venting Solutions Increased Maximum GPM (up to 11 GPM)

Longest 2” Vent Run in the Industry Low Gas Pressure Operation

2” Ring and Cap Integrated Controllers

Next Generation Concentric Venting Vertically Integrated for Precision and Quality

Integrated Check Valve

Room Air and unbalanced zones 3. Serviceability – To save time and simplify tasks

Multiple ways to common vent

Easy Hang Mounting Bracket Quick Change Components

Lowered Minimum Gas Pressure Stainless Steel Primary and Secondary HEX

Quick-n-Easy Gas Conversion Internal Insect trap

Easy Parameter Adjustment Vent Screen on Intake

Multi-Position PRV

3 Ideals to Captivate Customers

Product Line Up

Tankless Water Heater Changes

replaces the

SE+ Series

ADD

PICTURES

MANY

DIFFERENT

APPLICATION

S USING MANY

DIFFERENT

TYPES OF

VENTING

AVAILABLE

(FROM

MANUAL)

SENSEI Series Product Line Up

Application Min Btu Input Max Btu InputExisting Part

Number

New Part

NumberPump Model

Residential

(Indoor /

Outdoor)15,000

199,000 RUC98i / RU98e RU199i/e

180,000 RUC90i / RU90e RU180i/e

160,000 RU160i/e

152,000 RUC80i / RU80e

130,000 RU130i/e

199,000 RUR98i / RUR98e RUR199i/e Yes

160,000 RUR160i/e Yes

Commercial

(Indoor /

Outdoor)

199,000 C199i / C199e CU199i/e

160,000 CU160i/e

Most Solutions and Longest 2” Vent RunsRinnai

(SENSEI)Navien Noritz Rheem

Vent Manufacturer’s 9 4 2 2

2” Max Vent Length 65’ 60’ 50’ 50’

3” Max Vent Length 150’ 150’ 100’ 100’

2” PP Flex Vent Length 59’ 50’ -- --

Non-Direct Vent (Room Air) Yes Yes Yes * Yes *

3 X 5” Concentric Yes No No No

2 X 4” Concentric Yes No No No

1) Navien 240 A/s2) Noritz NRCP1112-DV3) Rheem RTGH-RH10DV1* Limited models

Concentric

Diameter Equivalent Length Termination

3 X 5 150’ (46 m) Vertical or Horizontal

2 X 4 (NEW) 65’ (20 m) Vertical or Horizontal

Twin Pipe and Room Air

Diameter MaterialEquivalent

LengthTermination

3” PP, PVC, CPVC 150’ (46 m)Vertical or Horizontal

2” (NEW) PP, PVC, CPVC 65’ (20 m)Vertical or Horizontal

2” Ring and Cap

• 3 X 5 inch reduces to 2 X 4 inch

• New tankless can go in an old

condensing vent system for

replacement if needed

• New install can have smaller, lighter,

less expensive concentric• Single penetration through the wall,

reducing install time and costs

• Simple positive-fit components for secure

connection

• Joint seals that expand and contract with

weather to prevent damage

• Ease of assembly and adjustment

SENSEI Series Concentric Venting

• Check valve integrated between the fan assembly and combustion chamber

• Creates additional venting solutions• Additional freeze protection• Stops backdraft of exhaust with common vent

Integrated Check Valve

• Room air can be used for combustion

• Unbalanced zones – Snorkel, T, many options

Additional Venting Solutions

Single Pipe

Diameter MaterialEquivalent

LengthTermination

3” PP, PVC, CPVC 150’ (46 m) Vertical or Horizontal

2” PP, PVC, CPVC 65’ (20 m) Vertical or Horizontal

Debris and bird screen

• Common Vent• Room Air Common Vent• No check valve above water heater reduces cost

and size of common vent

Multiple Solutions for Common Vent

Common VentHeader = all

components

above water

heaters

Vent = extensions

from header to

termination(starts equivalent length)

199k Btu Water Heater – Equivalent Length

# WH’s3” Header

3” Vent4” Header

4” Vent4” Header

6” Vent6” Header

6” Vent

2 65’150’

150’

150’

3 -

4 - 65’

5 - -

6 - -

7 - - 70’

8 - - -

160k Btu Water Heater – Equivalent Length

# WH’s3” Header

3” Vent4” Header

4” Vent4” Header

6” Vent6” Header

6” Vent

2 90’ 150’

150’ 150’3 - 100’

4 - 65’

** PPS for Canada available in 6 inch

Venting Summary

Venting Summary – Common Vent

• One person installation with Easy hang bracket and lightweight tankless

• Fits varying stud alignment

• Grooved bracket allows for water heater to be hung and then positionedADD Picture

Easy Hang Mounting Bracket

• Remove 3 screws, change the

orifice, parameter, and apply the

new data plate

• Stock and use the SKU’s that are

best for your customers

• Stock NG version + inexpensive

conversion kit.

• Stock propane unit for propane

rich locations.

Quick-n Easy Gas Conversion

NG:BLUE LP:RED

Orifice plate

• Integrated controls on internal and external models

• Installation efficiency with easily accessible control

panel and push button with 14 parameters

Easy Parameter Adjustments

ADD CHART

THAT SHOWS

OLD CHART

NEW CHART

OF

OPERATIONAL

GAS LIMITS.

Multi - Position PRV

PRV relocated for flexible

installation in multiple directions.

Can’t use existing isolation valves

Bottom View

Operational Performance

Turbo Fan- Feeds burner with gas/air mixture- Provides longest venting options

by any tankless manufacturer- Manufactured by Rinnai

Switching Venturi- Provides consistent mixture of air

and gas to burner- Self-compensates with low or

fluctuating gas pressures- Manufactured by Rinnai

Fiber Mesh Premix Burner- Provides even flame

distribution for optimal performance at any demand

- Manufactured by Rinnai

Primary Stainless Steel HEX- Resists the corrosive natureof the condensate, which occurs early in the high-efficiency combustion process. - Manufactured by Rinnai

Zero Governor Gas Valve- Optimizes combustion by

consistently delivering gas and air- Manufactured by Rinnai

Performance All components working together provide the best combustion performance possible

Integrated Flue Check Valve- Prevents backflow of

combustion gases in common vent systems

A parameter adjustment can be made for greater hot water flow (up to 11

GPM) in areas with low delta T. Maximum flow rates may vary based on set

temperature, and altitude

Increased Water Flow

Natural 3.5 in. w.c. - 10.5 in. w.c.

Propane 8.0 in. w.c. - 13.5 in. w.c.

The gas and air are premixed in the venturi

before delivery to the burner assembly.

Operational Performance

• The unit will self compensate (de-rate) in

areas with fluctuating or low gas pressures,

to optimize performance.

• Minimizes errors due to poor gas pressures

or air flow

Lower Minimum Gas Pressure

• Integrated MC-91-2 controller in

all water heaters. It is located

behind the front panel on external

units

• Cascade systems

• Residential units are linked with

EZ connect or MSB accessories

• Commercial units have onboard

cascade controls built into the

PCB (up to 24 units)

Operational Performance

Operational Performance - Recirculation

2. Bypass Mode1. Dedicated Return Line

Different plumbing configurations

• Two models available with

• RUR199 and the new smaller RUR160 with by-pass mode

• Select the accessory controller for desired recirculation

Operational Performance - Recirculation

Timer Based

Or Timer Based

Wireless Demand

1. MC195T 2.

• Customized interface for customer

• 4 unique programable schedules,

with multiple On/Off periods

• Vanity name each schedule

• 30 minute schedule increments

• Resets after loss of power

• Vacation mode

Operational Performance - Recirculation

• Mobile On-Demand

• 5 minute default

• 30 minute intervals up to 2 hours

• Upon completion reverts back to

saved schedules

Operational Performance - Recirculation

Serviceability

Quick Change Components

Designed for Serviceability

Every component was designed to be

removed in under 10 minutes

• Heat exchanger

• Water flow servo

• PCB (Data Transfer)

• Turbo Fan

• Etc.

Stainless Steel Primary Heat ExchangersThe SENSEI combustion system has several

new components working together in harmony.

• Zero governor gas valve

• Switching venturi

• Turbo fan

• Premix burner

The entire burner surface area comes on at

low inputs rather than a staged burner.

This combustion system is more efficient at

lower inputs and will produce condensate

earlier in the combustion process.

Stainless Steel Primary Heat ExchangersBecause of the potential for condensate at a low

inputs, Rinnai chose stainless steel on the

Primary Heat Exchanger

To further optimize durability:

Tubes are made from 444 SS which is superior for

corrosive properties, and has a lower coefficient of

expansion, and better thermal conductivity. The body

is also made from 400 series SS.

• The tube design incorporates a 1.0 mm wall

thickness vs. .8 mm tubes for extra durability.

• Fluorine gaskets are used at the joints rather than

EPDM for durability and heat resistance

Internal Insect Trap

• Internal insect trap

helps keep the

combustion system

clean

• Easy to remove

• Minimizes the need

and time to service

Intake vent screen

• Intake vent screen included with all units

• Use for room air or 2 pipe venting systems

Accessory and Venting Changes

ADD

PICTURES

MANY

DIFFERENT

APPLICATION

S USING MANY

DIFFERENT

TYPES OF

VENTING

AVAILABLE

(FROM

MANUAL)

2 X 4 Venting

Top converts 3 X 5 connection to 2 X 4 concentric

The rest of system is 2 X 4 concentric

At roof it converts back to 3 X 5

SENSEI Series 2 inch PP Options

Components in system:

• 2 inch PP pipe (1 and 2 meter)

• 45 and 90 degree elbows

• Metal clips to secure O-ring joints

• Adaptors to for concentric venting

if desired

• Flex vent with roof termination

Common VentHeader = all

components

above water

heaters

Vent = extensions

from header to

termination(starts equivalent length)

199k Btu Water Heater – Equivalent Length

# WH’s3” Header

3” Vent4” Header

4” Vent4” Header

6” Vent6” Header

6” Vent

2 65’150’

150’

150’

3 -

4 - 65’

5 - -

6 - -

7 - - 70’

8 - - -

160k Btu Water Heater – Equivalent Length

# WH’s3” Header

3” Vent4” Header

4” Vent4” Header

6” Vent6” Header

6” Vent

2 90’ 150’

150’ 150’3 - 100’

4 - 65’

** PPS for Canada available in 6 inch

Questions

Recommended