View
182
Download
3
Category
Tags:
Preview:
Citation preview
EMERSONSemi-Hermetic Compressor
Product Catalogue
The Industry Standard
Index
General Information
L Series
Model Nomenclature & Bill of Materials
Performance Data
50Hz R22
R404A/507
R134a
60Hz R22
R404A/507
R134a
Dimensional Drawing
Wiring Diagram
Terminal Jumper Schematics
Motor Current Data (A)
2S Series
Model Nomenclature & Bill of Materials
Performance Data
50Hz R22
R404A/507
R134a
60Hz R22
R404A/507
R134a
Dimensional Drawing
Wiring Diagram
Terminal Jumper Schematics
Motor Current Data (A)
3S Series
Model Nomenclature & Bill of Materials
Performance Data
50Hz R22
R404A/507
R134a
60Hz R22
R404A/507
R134a
Dimensional Drawing
Wiring Diagram
Terminal Jumper Schematics
Motor Current Data (A)
1
2-15
2
3
5
7
8
10
12
13
14
14
15
16-25
16
17
18
19
20
21
22
23
24
24
25
26-40
26
27
29
31
32
34
36
37
38
39
40
4S/6S Series
Model Nomenclature & Bill of Materials
4S Performance Data
50Hz R22
R404A/507
R407C
60Hz R22
R404A/507
R407C
6S Performance Data
50Hz R22
R404A/507
R407C
60Hz R22
R404A/507
R407C
Dimensional Drawing
4S
6S
Wiring Diagram
Terminal Jumper Schematics
Motor Current Data (A)
4S
6S
6T Series
Model Nomenclature & Bill of Materials
Performance Data
50Hz R22
R404A/507
60Hz R22
R404A/507
Dimensional Drawing
Wiring Diagram
Terminal Jumper Schematics
Motor Current Data (A)
All Series
Mechanical Data
Electrical Data
41-73
41
42
44
46
47
49
51
52
54
56
57
59
61
62
64
67
69
70
72
74-91
74
75
77
79
81
83
85
87
88
92-94
92
94
1
The first Copeland brand Semi-Hermetic compressor was produced in 1941. It was the first successful compressor to operate with an electric
motor inside the compressor casting. Since then Copeland brand Semi-Hermetic compressors have earned the reputation for its durability and
consistent quality and established itself as an Industry Standard.
Today Copeland brand Semi-Hermetic compressors are manufactured in five different plants world wide. All the Copeland manufacturing plants
are audited by an expert team on a regular basis to ensure a uniform global standard is implemented in all its manufacturing locations.
You can be assured that when you buy a Copeland brand Semi-Hermetic compressor you are buying one of the best compressors available in the
market.
This catalogue provides the basic technical information for the products made from our manufacturing facility in Shenyang, China. We are proud
to inform that the China manufacturing facility is a fully owned Copeland manufacturing plant and has consistently won the top “Gold” status
award in Copeland internal audits since the year 2004. Through this our China Semi-Hermetic facility has earned the reputation as the best Semi-
Hermetic plant.
General Information
Compressor Series And HP Range.
hp 2 3 4 5 8 10 15 20 25 30 32 35 40 50
S series
6S
4S
3S
2S
L series 6T – 2 Stage
Two stage series
2
L Series
Model Nomenclature & Bill of Materials
X X X X - X X X X - X X X - X X X
Oil TypeCode Description E Ester oil 0 Mineral oil
Compressor Motor TypeCode Phase Motor Type E Three Dual voltage
Model Variation
Bill of Materials
Displacement and Valve Plate
Compressor Motor Protection Code Type W Motor protection with Thermistors and module in the terminal box
Compressor seriesCode Description L Established For This Family
Electrical Code Code Voltage Ph Hz L 220-240 3 50 380-420Y 3 50 K 220-240 3 60 380-420Y 3 60
Design SeriesCode Description A Air cooled
Motor Rating Power Code HP 0200 2 0300 3 0400 4
L SeriesMounting PartsRotalock/Service ValveCrankcase HeaterMotor Protection Module
Bill of Materials (BOM)
202√√√√
3
L Series
50 Hz
Q
P
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
2530354045505560622530354045505560622530354045505525303540455055303540455055606230354045505560622530354045505525303540455055
Model
LA10-0200
LA20-0200
LA20-0300
LA40-0300
-50
0.600.50
0.900.80
1.100.90
1.201.20
-45
1.000.900.700.60
1.001.001.001.00
1.701.501.301.10
1.401.401.401.40
-40
1.100.900.800.700.600.40
1.001.000.900.900.900.80
1.501.301.201.000.900.800.601.201.201.201.201.201.101.101.401.201.100.900.800.60
1.201.201.201.201.101.10
2.402.201.901.70
1.701.701.701.70
-35
1.601.401.201.100.900.80
1.101.101.101.101.101.00
2.202.001.801.601.401.201.001.401.401.401.401.401.401.402.001.801.601.401.201.00
1.401.401.401.401.401.40
3.403.102.802.502.302.001.701.902.002.002.002.002.002.00
-30
2.101.901.801.601.401.201.100.900.901.301.301.301.301.301.301.201.201.203.002.702.502.302.001.801.601.601.701.701.701.701.701.702.702.502.202.001.801.601.401.301.601.701.701.701.701.701.701.704.504.203.803.503.202.902.602.202.202.302.302.402.402.50
-25
2.902.602.402.202.001.801.601.401.301.401.401.401.501.501.501.501.501.504.003.703.403.102.802.502.301.801.901.902.002.002.002.003.703.403.102.802.602.302.102.001.901.901.902.002.002.002.002.005.905.505.104.704.303.903.602.402.502.602.702.802.902.90
-20
3.803.503.202.902.602.402.201.901.801.501.601.601.601.701.701.701.701.705.204.804.504.103.803.403.102.002.102.102.202.302.302.404.804.504.103.803.503.202.902.702.002.102.202.202.302.302.402.407.607.106.606.205.705.204.802.602.802.903.103.203.303.40
-15
4.804.504.103.803.503.202.902.602.501.601.701.801.801.901.902.002.002.006.606.105.705.304.904.504.102.102.202.402.502.602.602.706.205.805.304.904.504.203.803.702.202.302.402.502.602.602.702.709.609.008.407.80
2.803.003.203.40
-10
6.005.605.204.804.404.103.703.403.301.701.801.902.002.102.102.202.302.308.207.707.206.706.20
2.202.402.502.702.80
7.807.306.706.305.805.304.904.702.402.502.602.802.903.003.003.10
11.9011.2010.50
3.003.303.50
0
9.108.608.007.506.906.405.905.405.201.701.902.102.202.402.502.602.702.80
11.6010.9010.209.508.808.207.607.302.502.702.903.103.303.503.603.70
-5
7.507.006.506.005.605.204.704.304.201.701.902.002.102.202.302.402.502.50
10.109.508.908.30
2.302.502.702.90
9.508.908.307.807.206.706.105.902.502.602.803.003.103.203.303.40
14.5013.7012.90
3.103.403.70
5
11.1010.409.709.108.407.807.30
1.701.902.102.302.502.702.80
13.8013.0012.2011.4010.609.909.108.902.502.803.003.303.503.703.903.90
7
11.9011.2010.509.809.108.507.80
1.601.902.102.302.502.702.90
14.8013.9013.1012.2011.4010.609.809.502.502.803.003.303.503.703.904.00
10
13.2012.4011.7010.9010.209.50
1.601.802.102.302.602.80
16.3015.3014.4013.5012.6011.80
2.402.703.003.303.603.80
12.5
14.4013.6012.7012.0011.2010.40
1.501.802.102.302.602.80
17.6016.6015.6014.7013.7012.80
2.302.703.003.303.603.90
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
4
L Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
303540455055606230354045505560622530354045505525303540455055
Model
LA40-0400
LA50-0400
-50
1.501.301.201.00
1.601.501.501.40
-45
2.202.001.801.60
1.901.901.901.80
-40
2.202.001.80
1.701.701.70
3.203.002.702.502.202.001.702.202.202.302.302.302.202.20
-35
3.102.802.502.302.001.80
2.002.002.002.002.002.00
4.504.203.803.503.202.902.602.602.602.702.702.702.802.80
-30
4.203.803.503.202.902.602.302.202.302.302.302.402.402.402.502.506.005.605.204.804.404.003.602.903.003.103.203.203.303.30
-25
5.605.104.704.303.903.603.203.102.502.602.702.802.802.902.902.907.707.206.706.205.805.304.903.203.403.503.603.703.803.90
-20
7.206.706.205.705.204.804.404.202.802.903.003.103.203.303.403.409.609.008.407.907.306.806.303.403.603.804.004.204.304.40
-15
9.108.507.907.306.706.205.705.503.003.203.303.503.603.703.903.90
-10
11.3010.609.809.108.407.807.206.903.203.403.603.804.004.204.304.40
0
16.5015.5014.5013.5012.6011.7010.80
3.503.804.104.404.704.905.20
-5
13.8012.9012.0011.2010.409.608.908.603.403.703.904.104.404.604.804.90
5
19.6018.4017.2016.1015.0014.00
3.503.904.304.605.005.30
7
20.8019.6018.4017.2016.10
3.503.904.304.705.00
10
22.9021.5020.2019.0017.70
3.403.904.304.805.20
12.5
24.7023.2021.8020.4019.10
3.403.904.304.805.20
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
5
L Series
50 Hz
Q
P
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20253035404550552025303540455055202530354045505520253035404550552025303540455055202530354045505520253035404550552025303540455055
Model
LA10-020E
LA20-020E
LA20-030E
LA40-030E
-50
0.800.60
0.700.70
1.401.100.80
1.201.101.00
-45
1.401.100.900.70
0.900.900.900.90
1.601.401.100.900.700.50
1.201.201.101.101.000.90
2.201.901.601.200.90
1.501.401.401.301.10
-40
1.501.301.100.800.60
0.900.900.900.800.70
2.001.701.501.201.000.80
1.101.101.101.101.101.10
2.202.001.701.501.301.000.800.601.401.401.401.401.301.201.201.103.202.802.402.101.701.301.00
1.801.701.701.601.601.401.30
-35
2.101.901.601.301.100.800.60
1.101.101.001.001.000.900.80
2.802.502.201.901.601.301.000.801.301.401.401.401.401.401.301.303.102.802.502.201.901.601.301.101.601.601.601.601.601.601.501.404.303.903.503.102.602.201.801.402.002.002.002.002.001.901.801.70
-30
2.802.502.302.001.701.401.100.801.201.201.201.201.201.101.101.003.703.303.002.602.301.901.601.301.501.601.601.601.701.701.701.604.103.703.303.002.602.302.001.601.701.801.901.901.901.901.801.805.805.304.704.203.703.202.702.202.302.302.402.402.402.402.302.30
-25
3.703.303.002.702.402.001.701.301.301.401.401.401.401.401.301.304.804.403.903.503.102.702.301.901.701.801.901.901.902.002.002.005.204.804.403.903.503.102.702.301.902.002.102.102.202.202.202.107.406.806.205.605.004.403.803.202.502.602.702.802.802.902.902.80
-20
4.704.303.903.503.102.702.301.901.501.501.601.601.601.601.601.606.105.605.104.504.003.503.102.601.902.002.102.202.202.302.302.306.606.105.605.104.604.103.603.102.002.102.302.402.402.502.502.509.308.607.907.206.505.805.104.402.802.903.103.203.303.403.403.40
-15
5.905.505.004.504.103.603.102.601.501.601.701.801.801.901.901.90
8.307.607.006.405.805.204.604.002.002.202.402.602.702.702.802.80
-10
7.306.806.205.705.104.604.003.401.601.701.801.902.002.102.102.20
10.209.408.607.907.206.505.805.102.002.302.502.702.903.003.103.20
0
10.9010.109.308.607.807.006.205.401.601.802.002.202.302.502.602.70
14.7013.7012.7011.7010.709.708.70
1.902.302.703.003.203.503.60
-5
8.908.307.707.006.405.705.004.301.601.801.902.102.202.302.402.50
12.3011.4010.509.708.808.007.106.302.002.302.602.903.103.203.403.50
5
13.0012.2011.3010.409.408.507.606.601.601.802.002.302.502.702.803.00
17.5016.3015.1013.9012.8011.7010.50
1.802.302.703.003.403.603.90
7
14.0013.0012.1011.2010.209.208.20
1.501.802.002.302.502.702.90
18.7017.4016.2014.9013.7012.5011.30
1.802.202.703.103.403.704.00
10
15.5014.5013.4012.4011.3010.309.10
1.501.802.002.302.502.803.00
12.5
16.8015.7014.6013.5012.4011.20
1.401.702.002.302.602.80
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
R404A /507R404A /507
6
L Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
202530354045505520253035404550552530354045505525303540455055
Model
LA40-040E
LA50-040E
-50
1.601.301.00
1.501.401.30
-45
2.302.001.701.401.100.90
1.601.601.601.501.401.20
2.502.201.801.401.10
1.801.801.701.601.50
-40
3.102.802.502.101.801.501.200.901.901.901.801.801.801.701.501.203.703.202.802.401.901.501.102.202.202.102.102.001.901.70
-35
4.303.903.503.102.702.301.901.502.102.102.102.202.202.102.001.805.004.504.003.503.002.502.002.602.602.602.602.502.402.30
-30
5.605.104.704.203.703.202.702.302.402.402.402.502.502.502.502.406.706.005.404.804.203.603.002.903.003.103.103.103.103.00
-25
7.206.706.105.504.904.403.803.202.602.702.702.802.903.003.002.908.607.807.106.405.604.904.103.303.403.503.603.603.703.70
-20
9.108.507.807.106.405.705.004.302.902.903.003.203.303.403.503.50
10.809.909.108.207.306.405.503.603.804.004.104.204.304.40
-15
11.4010.609.809.008.207.306.505.703.103.203.303.503.703.804.004.10
-10
14.0013.1012.1011.2010.209.208.207.303.303.403.603.804.004.204.404.60
0
20.4019.1017.9016.6015.3014.0012.70
3.603.704.004.304.604.905.30
-5
17.0015.9014.8013.7012.6011.5010.309.103.403.603.804.004.304.604.905.10
5
24.2022.8021.3019.9018.4016.9015.40
3.603.804.104.404.805.205.70
7
25.9024.3022.8021.3019.7018.2016.60
3.703.904.104.504.905.405.80
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
R404A /507R404A /507
7
L Series
50 Hz
Q
P
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
30354045505560623035404550556062303540455055606230354045505560623035404550556062303540455055606230354045505560623035404550556062
Model
LA10-020E
LA20-020E
LA40-030E
LA50-040E
-20
1.901.701.501.401.201.000.900.801.001.001.001.001.001.001.101.102.702.402.201.901.701.501.301.201.201.201.201.301.301.301.301.303.803.503.102.802.502.201.901.701.801.801.801.901.901.901.901.905.004.604.303.903.503.102.802.702.102.202.302.302.402.402.502.50
-15
2.602.302.101.901.701.501.301.301.101.101.101.201.201.201.201.203.503.202.902.602.402.101.801.701.301.401.401.401.501.501.501.505.004.604.203.803.403.102.702.602.002.002.102.202.202.202.302.306.506.005.605.104.704.303.803.702.402.502.602.702.702.802.902.90
-10
3.403.102.802.502.302.001.801.701.201.201.301.301.301.401.401.404.504.103.803.503.102.802.502.401.401.501.601.601.701.701.701.706.506.005.505.004.604.103.703.502.102.202.302.402.502.602.702.708.307.707.106.606.105.505.004.802.602.702.903.003.103.203.303.30
0
5.304.904.504.103.703.403.002.901.301.401.501.501.601.701.701.807.006.606.105.605.104.604.204.001.601.701.801.902.002.102.202.20
10.209.508.808.107.406.806.105.902.402.602.803.003.103.303.403.50
12.8012.0011.2010.409.608.808.007.703.003.203.403.603.804.004.104.20
-5
4.303.903.603.302.902.602.402.301.201.301.401.401.501.501.601.605.705.304.804.404.003.703.303.101.501.601.701.801.901.902.002.008.207.607.006.405.905.304.804.602.302.402.602.702.803.003.003.10
10.409.709.008.307.707.006.406.202.803.003.103.303.503.603.703.70
5
6.606.105.605.104.704.203.803.601.301.401.501.601.701.801.901.908.608.107.506.906.305.805.205.001.601.801.902.002.202.302.402.40
12.5011.7010.9010.109.208.507.707.402.502.703.003.203.403.603.803.90
15.6014.7013.7012.8011.8010.909.909.603.103.403.603.904.104.304.504.60
7
7.106.606.105.605.104.604.104.001.301.401.601.701.801.902.002.009.308.708.107.506.906.305.705.501.601.801.902.102.202.302.402.50
13.5012.6011.8010.9010.109.208.408.002.502.803.003.303.503.804.004.10
16.9015.8014.8013.8012.8011.8010.8010.403.103.403.704.004.304.504.704.80
10
8.007.406.906.305.805.204.704.501.301.401.601.701.902.002.102.10
10.509.809.108.507.807.106.406.201.601.802.002.102.302.402.502.60
15.1014.2013.2012.3011.4010.409.509.102.502.803.103.403.704.004.204.30
18.9017.8016.6015.5014.4013.3012.2011.703.203.503.804.104.404.704.905.00
12.5
8.808.207.607.006.405.805.205.001.301.501.601.801.902.002.202.20
11.5010.8010.109.308.607.90
1.601.802.002.202.302.50
16.6015.6014.6013.6012.5011.50
2.502.903.203.503.804.10
20.6019.5018.3017.0015.8014.60
3.203.603.904.304.604.90
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
8
L Series
60 Hz
Q
P
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
2530354045505560622530354045505560622530354045505525303540455055303540455055606230354045505560622530354045505525303540455055
Model
LA10-0200
LA20-0200
LA20-0300
LA40-0300
-50
0.700.60
1.101.00
1.301.10
1.401.40
-45
1.201.000.900.70
1.301.201.201.20
2.001.701.501.30
1.701.701.701.70
-40
1.301.101.000.800.700.50
1.201.201.101.101.101.00
1.801.601.401.201.000.900.701.501.501.501.401.401.401.301.601.401.201.100.900.70
1.501.501.401.401.401.30
2.802.602.302.00
2.002.002.002.00
-35
1.801.601.401.301.100.90
1.301.301.301.301.301.20
2.602.302.101.901.601.401.201.701.701.701.701.701.701.702.302.101.901.601.401.20
1.701.701.701.701.701.70
4.003.603.303.002.702.402.102.302.302.402.402.402.402.40
-30
2.502.302.101.801.601.401.301.101.001.501.501.501.501.501.501.501.501.403.503.202.902.702.402.101.901.902.002.002.002.002.002.003.202.902.702.402.101.901.701.602.002.002.002.002.002.002.002.005.404.904.504.103.803.403.002.602.702.802.802.902.902.90
-25
3.403.102.802.602.302.101.801.601.501.701.701.701.801.801.801.801.801.804.704.304.003.703.303.002.702.202.202.302.402.402.402.404.404.003.703.303.002.702.402.302.202.302.302.402.402.402.402.407.006.506.005.605.104.704.202.903.003.103.203.303.403.50
-20
4.404.103.803.403.102.802.502.302.201.801.901.902.002.002.002.102.102.106.105.705.304.804.404.103.702.402.502.602.702.702.802.805.705.304.904.504.103.703.403.202.502.602.602.702.802.802.802.809.008.407.807.306.706.205.703.203.303.503.703.803.904.10
-15
5.705.304.904.504.103.703.403.102.901.902.002.102.202.302.302.402.402.407.707.206.706.305.805.304.902.502.702.803.003.103.203.207.306.806.305.805.404.904.504.302.702.802.903.003.103.203.203.30
11.3010.609.909.30
3.403.603.904.10
-10
7.106.606.205.705.204.804.404.003.802.002.102.302.402.502.602.602.702.709.709.108.507.907.40
2.602.903.003.203.40
9.208.608.007.406.806.305.805.602.803.003.203.303.403.503.603.70
14.0013.2012.40
3.603.904.20
0
10.8010.109.408.808.207.607.006.406.202.002.302.502.702.903.003.203.303.30
13.6012.8012.0011.2010.409.708.908.603.003.303.503.804.004.204.404.40
-5
8.808.307.707.106.606.105.605.104.902.002.202.402.602.702.802.903.003.00
11.9011.2010.509.80
2.703.003.203.40
11.3010.609.909.208.507.907.207.003.003.203.403.603.703.904.004.10
17.1016.1015.20
3.704.104.50
5
13.1012.3011.5010.7010.009.308.60
2.002.302.502.803.003.203.40
16.3015.3014.4013.5012.6011.7010.8010.503.003.303.603.904.204.404.604.70
7
14.0013.2012.4011.6010.8010.009.30
2.002.302.502.803.003.303.50
17.4016.4015.4014.4013.5012.5011.6011.302.903.303.603.904.204.504.704.80
10
15.6014.7013.8012.9012.1011.20
1.902.202.502.803.103.30
19.2018.1017.0016.0014.9013.90
2.903.303.604.004.304.60
12.5
17.0016.0015.0014.1013.2012.30
1.802.102.502.803.103.40
20.7019.6018.4017.3016.2015.10
2.803.203.604.004.304.60
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
9
L Series
60 Hz
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
30354045505560623035404550556062
Model
LA40-0400
-40
2.602.302.10
2.002.002.00
-35
3.603.303.002.702.402.10
2.402.402.402.402.402.50
-30
5.004.504.103.703.403.002.702.602.702.802.802.902.902.903.003.00
-25
6.606.105.605.104.704.203.803.703.003.103.203.303.403.403.503.50
-20
8.507.907.306.706.205.605.205.003.403.503.603.803.904.004.104.10
-15
10.8010.009.308.607.907.306.706.503.603.804.004.204.304.504.604.70
-10
13.3012.5011.6010.8010.009.208.508.203.904.104.404.604.805.005.205.30
0
19.5018.3017.1016.0014.9013.80
4.204.604.905.305.605.90
-5
16.2015.2014.2013.2012.3011.40
4.104.404.705.005.205.50
5
23.0021.7020.3019.0017.70
4.204.705.105.505.90
7
24.6023.1021.7020.3019.00
4.204.705.205.606.10
10
27.0025.4023.8022.3020.90
4.104.705.205.706.20
12.5
29.1027.4025.7024.1022.60
4.004.605.205.806.30
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
10
L Series
60 Hz
Q
P
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20253035404550552025303540455055202530354045505520253035404550552025303540455055202530354045505520253035404550552025303540455055
Model
LA10-020E
LA20-020E
LA20-030E
LA40-030E
-50
1.000.70
0.900.80
1.701.301.00
1.401.401.20
-45
1.601.301.100.80
1.101.101.101.00
1.901.601.301.100.800.60
1.401.401.401.301.201.10
2.602.201.801.501.10
1.801.701.601.501.40
-40
1.801.501.201.000.70
1.101.101.001.000.90
2.402.101.701.401.200.90
1.401.401.401.401.301.30
2.602.302.001.801.501.200.900.701.701.701.701.601.601.501.401.303.703.302.902.402.001.601.20
2.102.102.002.001.901.701.60
-35
2.502.201.901.601.301.000.70
1.301.301.301.201.101.101.00
3.302.902.602.201.901.501.200.901.601.601.701.701.701.601.601.603.603.302.902.602.201.901.601.201.901.902.002.001.901.901.801.705.104.604.103.603.102.602.101.602.402.502.502.402.402.302.202.00
-30
3.303.002.702.302.001.601.301.001.501.501.501.501.401.401.301.204.403.903.503.102.702.301.901.501.901.901.902.002.002.002.002.004.804.303.903.503.102.702.301.902.102.202.202.302.302.202.202.106.806.205.605.004.403.803.202.602.702.802.902.902.902.902.802.70
-25
4.304.003.603.202.802.402.001.601.601.701.701.701.701.701.601.505.705.204.604.103.603.102.702.202.102.202.202.302.302.302.402.406.205.705.104.604.203.703.202.702.202.402.502.602.602.602.602.508.708.007.306.605.905.204.503.803.003.203.303.403.403.403.403.40
-20
5.505.104.604.203.703.202.802.301.801.801.901.901.901.901.901.907.206.606.005.404.804.203.603.102.302.402.502.602.702.702.702.807.807.206.606.005.404.804.203.602.402.502.702.802.903.003.003.00
11.0010.209.408.507.706.806.005.203.303.503.703.803.904.004.104.10
-15
6.906.405.905.404.804.203.703.101.902.002.102.102.202.202.302.30
9.709.008.307.506.806.105.404.702.402.702.903.103.203.303.403.40
-10
8.608.007.406.706.105.404.704.001.902.102.202.302.402.502.602.60
12.0011.1010.209.308.507.606.806.002.502.803.003.303.503.603.703.80
0
12.8011.9011.1010.209.208.307.306.401.902.202.402.602.803.003.103.30
17.4016.2015.0013.8012.6011.5010.30
2.302.803.203.603.904.204.40
-5
10.609.809.108.307.506.705.905.102.002.202.302.502.602.802.902.90
14.5013.5012.4011.4010.409.408.407.502.402.803.203.403.703.904.104.20
5
15.4014.3013.3012.2011.2010.108.907.801.902.202.502.703.003.203.403.60
20.6019.2017.8016.4015.1013.8012.40
2.202.703.203.704.004.404.70
7
16.5015.4014.3013.2012.0010.809.60
1.802.202.502.703.003.303.50
22.0020.5019.1017.6016.2014.8013.40
2.102.703.203.704.104.404.80
10
18.3017.1015.9014.6013.4012.1010.80
1.802.102.402.803.103.303.60
12.5
19.8018.6017.3015.9014.6013.20
1.702.002.402.803.103.40
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
R404A /507R404A /507
11
L Series
60 Hz
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20253035404550552025303540455055
Model
LA40-040E
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
-45
2.702.302.001.701.301.00
2.001.901.901.801.701.50
-40
3.703.302.902.502.101.801.401.002.302.202.202.202.102.001.801.40
-35
5.004.604.103.603.102.702.201.802.602.602.602.602.602.502.402.10
-30
6.606.105.504.904.403.803.202.702.902.902.903.003.003.103.002.80
-25
8.507.907.206.505.805.104.503.803.203.203.303.403.503.603.603.50
-20
10.8010.009.208.407.606.705.905.103.403.503.603.804.004.104.204.20
-15
13.5012.5011.6010.609.608.707.706.703.703.804.004.204.404.604.804.90
-10
16.5015.4014.3013.2012.1010.909.70
3.904.104.304.504.805.105.30
-5
20.0018.8017.5016.2014.8013.5012.20
4.104.304.504.805.205.505.90
0
24.0022.6021.1019.6018.0016.50
4.304.504.705.105.505.90
5
28.6026.9025.1023.4021.7019.90
4.404.604.905.305.806.30
7
30.5028.7026.9025.1023.3021.40
4.404.605.005.405.906.40
R404A /507R404A /507
12
L Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
303540455055606230354045505560623035404550556062303540455055606230354045505560623035404550556062
Model
LA10-020E
LA20-020E
LA40-030E
-20
2.302.001.801.601.401.201.101.001.201.201.201.201.201.301.301.303.102.802.602.302.001.701.501.401.401.401.501.501.501.501.501.504.504.103.703.302.902.502.202.002.102.202.202.302.302.302.302.30
-15
3.102.802.502.202.001.801.601.501.301.301.401.401.401.401.501.504.103.803.403.102.802.502.202.101.601.601.701.701.801.801.801.805.905.505.004.504.103.603.203.002.302.402.502.602.602.702.702.70
-10
4.003.603.303.002.702.402.102.001.401.501.501.601.601.601.701.705.304.904.504.103.703.303.002.801.701.801.901.902.002.002.102.107.607.106.505.905.404.904.304.102.502.702.802.903.003.103.203.20
0
6.305.805.304.904.404.003.603.401.501.601.701.801.902.002.102.108.307.707.206.606.005.504.904.701.902.002.202.302.402.502.602.60
12.0011.2010.409.608.808.007.206.902.903.103.303.603.804.004.104.20
-5
5.004.604.203.803.503.102.802.701.501.601.601.701.801.801.901.906.706.205.705.204.804.303.903.701.801.902.002.102.202.302.302.409.608.908.307.606.906.305.705.402.702.903.103.303.403.503.703.70
5
7.807.206.606.105.505.004.504.301.601.701.802.002.102.202.302.30
10.209.508.808.207.506.806.205.901.902.102.302.502.602.702.802.90
14.7013.8012.8011.9010.9010.009.108.703.003.303.603.904.104.404.604.70
7
8.407.807.206.606.005.404.904.701.601.701.902.002.102.302.402.40
11.1010.309.608.908.107.406.706.401.902.102.302.502.702.802.903.00
15.9014.9013.9012.9011.9010.909.909.503.003.303.704.004.304.504.804.90
10
9.408.808.107.406.806.205.505.301.601.701.902.102.202.402.502.60
12.4011.6010.8010.009.208.407.607.301.902.102.402.602.702.903.003.10
17.8016.7015.6014.5013.4012.3011.2010.803.003.403.804.104.504.805.105.20
12.5
10.409.608.908.207.506.806.105.801.501.701.902.102.302.402.602.70
13.6012.7011.9011.0010.209.30
1.902.102.402.602.803.00
19.6018.4017.2016.0014.8013.60
3.003.403.804.204.605.00
Evaporating Temperature oCCondensingTemperature
oC
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
13
L Series
Dimensional Drawing
LA10-LA50
MODEL
LA10-0200/LA10-020E
LA20-0200/LA20-020E
LA20-0300/LA20-030E
LA40-0300/LA40-030E
LA40-0400/LA40-040E
LA50-0400/LA50-040E
SL Ø(Suction Line)
22 mm
22 mm
22 mm
28 mm
28 mm
28 mm
DL Ø(Discharge Line)
15 mm
15 mm
15 mm
15 mm
15 mm
15 mm
A(Mounting Length)
295 mm
295 mm
295 mm
295 mm
295 mm
295 mm
B(Mounting Length)
279 mm
279 mm
279 mm
279 mm
279 mm
279 mm
L(Length)
460 mm
460 mm
460 mm
460 mm
460 mm
460 mm
W(Width)
330 mm
330 mm
330 mm
330 mm
330 mm
330 mm
H(Height)
385 mm
385 mm
385 mm
385 mm
385 mm
385 mm
SL – Suction Line (rotalock) DL – Discharge Line (rotalock)
4. Sleeve (Crankcase heater) 3/8” - 18NPSL
5. Plug 1/4” - 18NPTF
6. Magnetic Plug 1/8” - 27NPTF
1. Schrader-low pressure connection 1/8” - 27NPTF
2. Schrader – high-pressure connection 1/8” - 27NPTF
3. Plug Oil Charge 1/4” - 18NPTF
14
L Series
Wiring Diagram
Terminal Jumper Schematics
U V W
Z X Y
Y
Wiring Diagram LA10 - LA50
Control Circuit 220-240V-1-50/60Hz
Jumper Connection
Electrical Diagram Coding
A1 Motor protection module
A2: Thermistor
A5 Terminal box
B1 Thermostat
F1 Fuse for control circuit
F3 H/L pressure relays
F6, F7, F8: Fuses for main circuit
H1 Alarm indicator
K1 Compressor contactor coil
K5 Fan motor contactor coil
L : Phase Voltage
L1, L2, L3: Voltage connection:
380-420V-3-50/60 Hz -Y
220-240V-3-50/60Hz -Delta
N Neutral connection
Q1 Main Switch
R2 Crankcase heater
U, V, W, X,Y, Z: Phase Voltages
1-12, Accessory Connectors
Note: In A1 there is another 1 and 2,11,12, 14 (Terminals of Motor Protection Module)
A switch can be added to the crankcase heater circuit.
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
1(U) 2(V) 3(W)
7(Z) 8(X) 9(Y)
L1 L2 L3
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
Direct-on-line startY-
Direct-on-line start Direct-on-line startY
Star-delta-motorY-D
Code E
15
L Series
Motor Current Data (A)
-50
4.2/N/A
7.3/N/A
-45
3.4/4.1
4.1/4.9
4.5/N/A
3.9/4.7
3.4/4.1
4.3/5.1
4.2/N/A
5.9/7.2
7.1/8.6
7.8/N/A
6.7/8.2
5.9/7.2
7.4/8.9
7.3/N/A
-40
3.5/4.2
3.6/4.3
3.7/4.5
4.3/5.2
4.3/5.2
5.0/N/A
2.7/3.2
2.7/3.3
4.1/4.9
3.8/4.6
4.6/5.5
4.7/N/A
6.1/7.4
6.3/7.5
6.4/7.9
7.4/9.1
7.4/9.1
8.7/N/A
4.7/5.6
4.7/5.8
7.1/8.6
6.6/8.1
8.0/9.6
8.1/N/A
-35
3.6/4.3
3.7/4.5
3.9/4.7
4.6/5.6
4.6/5.6
5.5/N/A
2.9/3.5
3.0/3.6
4.4/5.2
4.3/5.2
4.9/5.9
5.4/N/A
6.3/7.5
6.4/7.9
6.7/8.2
8.0/9.8
8.0/9.8
9.5/N/A
5.0/6.1
5.2/6.3
7.6/9.1
7.4/9.1
8.5/10.3
9.3/N/A
-30
3.7/4.4
4.0/4.8
4.2/5.0
5.0/6.0
5.0/6.0
6.0/N/A
3.2/3.8
3.4/4.0
4.6/5.5
4.9/5.9
5.3/6.4
6.2/N/A
6.4/7.7
6.9/8.4
7.3/8.8
8.7/10.5
8.7/10.5
10.4/N/A
5.5/6.7
5.9/7.0
8.0/9.6
8.5/10.3
9.2/11.2
10.7/N/A
-25
3.8/4.6
4.2/5.1
4.4/5.3
5.4/6.5
5.4/6.4
6.5/N/A
3.4/4.1
3.7/4.5
4.8/5.8
5.5/6.6
5.8/7.0
7.0/N/A
6.6/8.1
7.3/8.9
7.6/9.3
9.3/11.4
9.3/11.2
11.2/N/A
5.9/7.2
6.4/7.9
8.3/10.2
9.5/11.6
10.0/12.3
12.1/N/A
-20
4.0/4.8
4.5/5.4
4.7/5.6
5.8/6.9
5.8/6.9
7.0/N/A
3.7/4.4
4.2/5.0
5.1/6.1
6.2/7.4
6.3/7.5
7.9/N/A
2.8/3.3
2.8/3.4
4.2/5.1
5.1/N/A
6.9/8.4
7.8/9.4
8.1/9.8
10.0/12.0
10.0/12.1
12.1/N/A
6.4/7.7
7.3/8.8
8.8/10.7
10.7/13.0
10.9/13.1
13.7/N/A
4.8/5.8
4.8/6.0
7.3/8.9
8.8/N/A
-15
4.1/5.0
4.7/5.7
4.9/5.9
6.2/7.4
6.2/7.4
3.9/4.7
5.3/6.4
6.7/8.1
2.9/3.5
3.0/3.6
4.5/5.4
5.4/N/A
7.1/8.8
8.1/10.0
8.5/10.3
10.7/13.0
10.7/13.0
6.7/8.2
9.2/11.2
11.6/14.2
5.0/6.1
5.2/6.3
7.8/9.5
9.3/N/A
-10
4.3/5.1
5.0/6.0
5.2/6.2
6.5/7.8
4.2/5.0
5.5/6.6
7.2/8.6
3.0/3.6
3.1/3.8
4.7/5.7
5.8/N/A
7.4/8.9
8.7/10.5
9.0/10.9
11.2/13.7
7.3/8.8
9.5/11.6
12.5/15.1
5.2/6.3
5.4/6.7
8.1/10.0
10.0/N/A
-5
4.4/5.3
5.2/6.3
5.4/6.5
6.9/8.2
4.2/5.3
5.8/6.9
7.6/9.1
3.2/3.8
3.3/4.0
5.0/6.0
6.1/N/A
7.6/9.3
9.0/11.0
9.3/11.4
11.9/14.4
7.3/9.3
10.0/12.1
13.1/15.9
5.5/6.7
5.7/7.0
8.7/10.5
10.6/N/A
0
4.5/5.4
5.5/6.6
7.1/8.6
4.6/5.6
6.0/7.2
7.9/9.5
3.3/3.9
3.4/4.1
5.2/6.3
6.5/N/A
7.8/9.5
9.5/11.6
12.3/15.1
8.0/9.8
10.4/12.6
13.4/16.6
5.7/6.8
5.9/7.2
9.0/11.0
11.2/N/A
5
4.6/5.5
5.6/6.8
7.3/8.8
4.8/5.8
6.1/7.4
8.2/9.8
3.4/4.0
3.6/4.3
5.5/6.6
6.8/N/A
8.0/9.6
9.7/11.9
12.6/15.4
8.3/10.2
10.6/13.0
14.2/17.2
5.9/7.0
6.2/7.5
9.5/11.6
11.8/N/A
10
4.7/5.6
5.7/6.8
7.4/8.9
4.9/5.9
3.4/4.1
3.6/4.3
5.6/6.8
7.0/N/A
8.1/9.8
9.9/11.9
12.8/15.6
8.5/10.3
5.9/7.2
6.3/7.5
9.7/11.9
12.11/N/A
12.5
4.7/5.6
5.6/6.8
7.5/9.0
5.0/6.0
3.5/4.2
3.6/4.4
5.7/6.9
7.1/N/A
8.1/9.8
9.7/11.9
13.0/15.8
8.7/10.5
6.1/7.4
6.2/7.7
9.9/12.1
12.3/N/A
LA10-0200
LA20-0200
LA20-0300
LA40-0300
LA40-0400
LA50-0400
LA10-020E
LA20-020E
LA20-030E
LA40-030E
LA40-040E
LA50-040E
LA10-020E
LA20-020E
LA40-030E
LA50-040E
LA10-0200
LA20-0200
LA20-0300
LA40-0300
LA40-0400
LA50-0400
LA10-020E
LA20-020E
LA20-030E
LA40-030E
LA40-040E
LA50-040E
LA10-020E
LA20-020E
LA40-030E
LA50-040E
R22 (400V-3-50Hz/380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °C
Star (Y) Connection
Model
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5
R134a (400V-3-50Hz/380V-3-60Hz) tc=40°C(CT)
Evaporating temperature °C
Star (Y) Connection
Model10 12.5
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5
R22 (230V-3-50Hz/230V-3-60Hz) tc =40°C(CT)
Evaporating temperature °C
Delta Connection
Model10 12.5
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5
R134a (230V-3-50Hz/230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °C
Delta Connection
Model10 12.5
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5
R404A/R507 (400V-3-50Hz/380V-3-60Hz) tc=40°C(CT)
Evaporating temperature °C
Star (Y) Connection
Model10 12.5
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5
R404A/R507 (230V-3-50Hz/230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °C
Delta Connection
Model10 12.5
16
2S Series
Model Nomenclature & Bill of Materials
X X X X - X X X X - X X X - X X X
Design Series
Model Variation
Bill of Materials
Displacement and Valve Plate
Compressor Motor Type Code Phase Motor Type E Three Dual voltage
Motor Rating Power Code HP 0550 5.5 0750 7.5
Compressor Motor ProtectionCode Type W Motor protection with Thermistors and module in the terminal box
Electrical Code Code Voltage Ph Hz L 220-240∆ 3 50 380-420Y 3 50 K 220-240∆ 3 60 380-420Y 3 60
Compressor Series Code Description 2 2 Cylinder
2S SeriesMounting PartsRotalock/Service ValveCrankcase HeaterElectronic Oil Pressure Switch (OPS2)Motor Protection Module
Bill of Materials (BOM)
000√√√√√
Oil TypeCode Description E Ester oil 0 Mineral oil
17
2S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
1015202530354045505560621015202530354045505560621015202530354045505560621015202530354045505560621015202530354045505510152025303540455055
Model
2SCW-0550
2SKW-0750
2SCW-0550 Air
-40
4.103.603.102.602.101.70
2.402.402.502.502.402.40
5.504.904.403.803.302.70
2.903.003.103.103.203.20
4.804.404.103.803.403.102.802.501.801.502.302.402.402.502.502.502.602.602.602.50
-35
5.705.204.704.203.603.102.60
2.702.802.802.902.902.902.90
7.306.706.105.504.904.303.70
3.203.403.503.603.603.703.70
6.405.905.505.104.704.404.003.603.303.002.502.702.802.903.003.003.103.103.203.20
-30
7.607.106.505.905.304.704.203.60
2.903.103.203.303.403.403.403.50
9.408.808.207.707.106.205.504.90
3.503.703.904.004.104.204.204.30
8.207.707.206.806.305.805.405.004.604.202.803.003.103.303.403.503.603.703.803.90
-25
9.809.208.608.007.306.706.005.404.80
3.103.303.503.703.803.904.004.104.20
11.9011.3010.609.909.208.607.606.906.20
3.704.004.204.404.604.704.805.005.10
10.509.909.308.708.107.607.10
3.003.203.503.703.804.004.20
Evaporating Temperature oCCondensingTemperature
oC
Notes:
-20
12.5011.8011.1010.409.608.908.207.506.706.00
3.203.503.804.004.204.404.604.704.905.00
14.9014.2013.4012.6011.8011.0010.309.508.307.50
3.804.204.504.805.105.305.505.605.806.00
13.1012.4011.7011.0010.309.70
3.103.403.704.004.204.50
-15
15.5014.8014.0013.2012.3011.5010.709.809.008.207.407.103.203.603.904.304.504.805.105.305.505.706.006.00
18.4017.5016.6015.7014.8013.9013.0012.1011.209.909.008.703.704.304.705.105.505.806.106.306.606.807.107.20
16.1015.3014.5013.7012.90
3.103.503.904.204.60
-10
19.1018.2017.3016.4015.4014.5013.6012.6011.7010.809.809.503.103.604.004.404.805.205.505.806.206.506.806.90
22.5021.4020.4019.3018.3017.2016.1015.1014.0013.0012.0011.503.504.204.805.305.806.206.607.007.307.708.008.20
19.6018.7017.7016.8015.80
3.003.504.004.404.80
-5
23.1022.1021.0020.0019.0017.9016.9015.8014.8013.7012.7012.202.903.504.004.505.005.505.906.306.707.107.507.70
27.2026.0024.7023.5022.2021.0019.8018.5017.3016.1014.9014.403.103.904.705.406.006.607.107.608.108.509.009.20
23.6022.5021.4020.30
2.803.404.004.50
-45
3.503.202.902.602.302.101.401.10
2.002.002.102.102.102.102.002.00
1. Suction Gas Temperature 20°C2. Suction Superheat 20K3. Suction Superheat 20K + Fan4. Liquid subcooling 0K
18
2S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
Model
2SCW-055E
2SKW-075E
-40
4.40
4.00
3.60
3.20
2.50
2.10
1.60
1.20
2.70
2.70
2.70
2.60
2.50
2.40
2.30
2.10
5.20
4.60
4.10
3.50
2.90
2.40
1.90
1.50
3.30
3.30
3.30
3.30
3.30
3.20
3.20
3.10
-35
6.00
5.50
5.10
4.60
4.00
3.50
2.60
2.10
3.10
3.20
3.20
3.20
3.20
3.10
3.00
2.90
7.10
6.40
5.80
5.10
4.40
3.80
3.20
2.70
3.80
3.90
3.90
4.00
4.00
4.00
4.00
3.90
-30
7.90
7.40
6.80
6.20
5.50
4.90
4.30
3.60
3.50
3.70
3.80
3.80
3.80
3.80
3.80
3.70
9.40
8.60
7.80
7.00
6.20
5.40
4.70
4.00
4.20
4.40
4.50
4.60
4.70
4.70
4.80
4.80
-25
10.20
9.50
8.80
8.10
7.30
6.50
5.80
5.00
3.90
4.10
4.30
4.40
4.50
4.50
4.50
4.50
12.10
11.10
10.20
9.20
8.20
7.30
6.30
5.50
4.70
4.90
5.10
5.30
5.40
5.50
5.60
5.70
Evaporating Temperature oCCondensingTemperature
oC
Notes:
-20
12.90
12.10
11.20
10.40
9.40
8.50
7.50
6.60
4.20
4.50
4.80
5.00
5.10
5.30
5.30
5.30
15.30
14.10
12.90
11.70
10.60
9.40
8.30
7.20
5.10
5.40
5.70
5.90
6.10
6.30
6.50
6.60
-15
16.00
15.00
14.00
13.00
11.90
10.80
9.60
8.50
4.40
4.80
5.20
5.50
5.70
5.90
6.10
6.20
19.00
17.50
16.10
14.70
13.30
11.90
10.50
9.20
5.40
5.80
6.20
6.60
6.80
7.10
7.30
7.50
-10
19.60
18.40
17.20
16.00
14.70
13.40
12.10
10.70
4.50
5.00
5.50
5.90
6.30
6.60
6.80
7.00
23.20
21.50
19.80
18.20
16.50
14.80
13.10
11.50
5.70
6.20
6.70
7.10
7.50
7.90
8.20
8.40
-5
23.60
22.30
20.90
19.50
18.00
16.40
14.90
13.30
4.50
5.20
5.80
6.30
6.80
7.20
7.50
7.80
28.10
26.10
24.10
22.10
20.10
18.10
16.10
14.20
5.90
6.50
7.10
7.70
8.20
8.60
9.00
9.40
-45
3.20
2.80
2.20
1.90
1.50
1.20
2.20
2.20
2.10
2.00
1.90
1.80
3.60
3.10
2.60
2.10
1.60
1.20
2.70
2.70
2.70
2.60
2.60
2.50
1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan4. Liquid subcooling 0K
R404A /507R404A /507
19
2S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
Model
2SCW-055E
2SKW-075E
-15
8.40
8.00
7.60
7.10
6.70
6.20
5.70
5.20
4.70
3.80
2.70
2.90
3.00
3.10
3.20
3.30
3.40
3.40
3.50
3.50
9.50
9.00
8.40
7.90
7.40
6.90
6.40
5.90
5.40
4.40
3.10
3.30
3.50
3.60
3.70
3.80
3.90
4.00
4.10
4.10
-10
10.70
10.20
9.60
9.10
8.50
7.90
7.30
6.70
6.10
5.40
2.80
3.10
3.30
3.50
3.60
3.70
3.80
3.90
4.00
4.10
12.20
11.50
10.80
10.10
9.50
8.80
8.20
7.60
7.00
6.40
3.30
3.50
3.80
4.00
4.10
4.30
4.40
4.50
4.70
4.80
-5
13.40
12.80
12.10
11.40
10.70
9.90
9.20
8.40
7.60
6.80
2.90
3.20
3.50
3.70
3.90
4.10
4.30
4.40
4.50
4.60
15.30
14.50
13.60
12.80
12.00
11.20
10.40
9.60
8.90
8.10
3.40
3.70
4.00
4.30
4.50
4.70
4.90
5.10
5.30
5.40
0
16.60
15.80
15.00
14.10
13.20
12.30
11.40
10.50
9.50
8.50
2.90
3.30
3.60
4.00
4.20
4.50
4.70
4.90
5.10
5.20
19.10
18.00
16.90
15.90
14.90
13.90
12.90
12.00
11.10
10.20
3.50
3.90
4.20
4.50
4.80
5.10
5.40
5.60
5.90
6.10
Evaporating Temperature oCCondensingTemperature
oC 5
20.40
19.40
18.40
17.30
16.20
15.10
14.00
12.80
11.70
10.50
2.80
3.30
3.70
4.10
4.50
4.80
5.10
5.30
5.60
5.80
23.40
22.10
20.80
19.50
18.30
17.10
15.90
14.70
13.60
12.50
3.40
3.90
4.30
4.80
5.10
5.50
5.80
6.10
6.40
6.70
7
22.10
21.00
19.90
18.70
17.50
16.30
15.10
13.90
12.60
11.30
2.70
3.20
3.70
4.10
4.50
4.90
5.20
5.50
5.80
6.00
25.40
23.90
22.50
21.10
19.80
18.50
17.20
15.90
14.70
13.50
3.40
3.90
4.40
4.80
5.20
5.60
6.00
6.30
6.60
7.00
10
23.50
22.30
21.00
19.70
18.30
16.90
15.60
14.10
12.70
3.10
3.70
4.10
4.60
5.00
5.40
5.70
6.00
6.30
26.90
25.30
23.70
22.20
20.70
19.30
17.90
16.50
15.10
3.90
4.40
4.90
5.40
5.80
6.20
6.60
7.00
7.30
12.5
25.80
24.40
23.00
21.60
20.10
18.60
17.10
15.50
14.00
3.00
3.60
4.10
4.60
5.10
5.50
5.90
6.20
6.50
29.50
27.80
26.00
24.40
22.70
21.20
19.60
18.10
16.60
3.80
4.40
4.90
5.40
5.90
6.40
6.80
7.20
7.60
-20
6.50
6.20
5.90
5.50
5.20
4.80
4.40
3.70
3.30
2.80
2.50
2.60
2.70
2.80
2.80
2.90
2.90
2.90
3.00
3.00
7.30
6.90
6.50
6.10
5.70
5.30
4.90
4.00
3.60
3.20
2.90
3.00
3.20
3.30
3.30
3.40
3.40
3.50
3.50
3.50
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Liquid subcooling 0K
20
2S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
1015202530354045505560621015202530354045505560621015202530354045505560621015202530354045505560621015202530354045505510152025303540455055
Model
2SCW-0550
2SKW-0750
2SCW-0550 Air
-40
4.904.303.703.102.502.00
2.902.903.003.002.902.90
6.505.805.204.502.503.20
3.403.603.703.703.803.80
5.705.204.804.404.003.703.303.002.101.802.702.802.903.003.003.103.103.103.103.10
-35
6.706.105.504.904.303.603.00
3.203.303.403.503.503.503.40
8.607.907.206.505.805.104.40
3.804.004.204.304.304.404.40
7.507.006.506.005.605.104.704.303.903.603.103.203.403.503.603.603.703.803.803.80
-30
9.008.307.707.006.305.604.904.30
3.503.703.804.004.004.104.104.20
11.1010.409.709.008.407.306.505.80
4.204.404.604.804.905.005.105.20
9.709.108.508.007.406.906.405.905.405.003.303.603.804.004.104.204.404.504.504.60
-25
11.6010.9010.209.408.607.907.106.405.60
3.704.004.204.404.604.704.804.905.00
14.1013.3012.5011.7010.9010.209.008.107.30
4.404.805.105.305.505.705.805.906.10
12.4011.7011.0010.309.609.008.30
3.603.904.104.404.604.805.00
Evaporating Temperature oCCondensingTemperature
oC
Notes:
-20
14.7013.9013.1012.3011.4010.509.608.807.907.10
3.804.204.504.805.005.305.505.705.806.00
17.6016.7015.8014.9013.9013.0012.1011.209.808.90
4.505.005.405.806.106.306.606.807.007.20
15.4014.6013.8013.0012.2011.40
3.704.104.404.805.105.40
-15
18.3017.4016.5015.5014.6013.6012.6011.6010.709.708.808.403.804.304.705.105.505.806.106.406.606.907.107.30
21.7020.7019.6018.5017.5016.4015.3014.3013.2011.8010.7010.204.505.105.706.206.607.007.307.607.908.208.508.60
19.0018.0017.1016.1015.20
3.704.204.705.105.50
-10
22.5021.4020.4019.3018.2017.1016.0014.9013.8012.7011.6011.203.704.304.805.305.806.206.607.007.407.808.108.30
26.6025.3024.0022.8021.5020.3019.0017.8016.5015.3014.1013.604.205.005.806.407.007.508.008.408.809.209.609.80
23.1022.0020.9019.8018.70
3.604.204.805.305.80
-5
27.2026.0024.8023.6022.4021.1019.9018.7017.4016.2014.9014.403.504.204.805.506.006.607.107.608.108.609.009.20
32.1030.7029.2027.7026.2024.8023.3021.8020.4019.0017.5017.003.704.705.706.507.207.908.609.109.70
10.3010.8011.0027.9026.5025.2023.90
3.404.104.805.40
-45
4.103.803.403.102.502.501.601.30
2.402.402.502.502.502.502.502.40
1. Suction Gas Temperature 20°C2. Suction Superheat 20K3. Suction Superheat 20K + Fan4. Liquid subcooling 0K
21
2S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
Model
2SCW-055E
2SKW-075E
-40
5.20
4.80
4.30
3.80
2.90
2.40
1.90
1.50
3.20
3.20
3.20
3.10
3.00
2.90
2.80
2.60
6.50
5.80
5.10
4.10
3.50
2.90
2.30
1.80
3.90
4.00
4.00
4.00
3.90
3.90
3.80
3.70
-35
7.10
6.50
6.00
5.40
4.80
4.20
3.10
2.50
3.70
3.80
3.90
3.90
3.80
3.70
3.60
3.50
8.80
8.00
7.20
6.50
5.70
4.50
3.80
3.10
4.50
4.60
4.70
4.80
4.80
4.80
4.70
4.70
-30
9.40
8.70
8.00
7.30
6.50
5.80
5.00
4.30
4.20
4.40
4.50
4.60
4.60
4.60
4.50
4.40
11.50
10.60
9.70
8.80
7.90
7.00
6.20
4.70
5.10
5.30
5.40
5.60
5.60
5.70
5.70
5.70
-25
12.10
11.30
10.40
9.50
8.60
7.70
6.80
5.90
4.70
4.90
5.10
5.30
5.40
5.50
5.50
5.40
14.80
13.70
12.60
11.50
10.40
9.30
8.30
7.30
5.60
5.90
6.10
6.40
6.50
6.60
6.70
6.80
Evaporating Temperature oCCondensingTemperature
oC
Notes:
-20
15.20
14.30
13.30
12.20
11.20
10.00
8.90
7.70
5.00
5.40
5.70
6.00
6.20
6.30
6.40
6.40
18.70
17.30
16.00
14.60
13.30
12.00
10.80
9.50
6.10
6.50
6.80
7.10
7.40
7.60
7.80
7.90
-15
18.90
17.70
16.60
15.30
14.00
12.70
11.40
10.00
5.30
5.80
6.20
6.60
6.90
7.10
7.30
7.40
23.10
21.50
19.90
18.30
16.70
15.20
13.60
12.10
6.50
7.00
7.50
7.90
8.20
8.50
8.80
9.00
-10
23.10
21.70
20.30
18.90
17.40
15.80
14.20
12.60
5.40
6.10
6.60
7.10
7.60
7.90
8.20
8.40
28.30
26.40
24.50
22.50
20.70
18.80
17.00
15.10
6.80
7.50
8.00
8.60
9.00
9.50
9.80
10.20
-5
27.80
26.30
24.60
22.90
21.20
19.40
17.50
15.60
5.40
6.20
6.90
7.60
8.10
8.60
9.00
9.40
34.20
32.00
29.70
27.40
25.20
23.00
20.80
18.60
7.00
7.80
8.60
9.20
9.80
10.40
10.90
11.30
-45
3.80
3.30
2.60
2.20
1.80
1.40
2.60
2.60
2.50
2.40
2.30
2.20
4.50
4.00
3.10
2.50
1.90
1.40
3.30
3.30
3.20
3.20
3.10
3.00
1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan4. Liquid subcooling 0K
R404A /507R404A /507
22
2S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
Model
2SCW-055E
2SKW-075E
-15
10.08
9.60
9.12
8.52
8.04
7.44
6.84
6.24
5.64
4.56
3.24
3.48
3.60
3.72
3.84
3.96
4.08
4.08
4.20
4.20
11.40
10.80
10.08
9.48
8.88
8.28
7.68
7.08
6.48
5.28
3.72
3.96
4.20
4.32
4.44
4.56
4.68
4.80
4.92
4.92
-10
12.84
12.24
11.52
10.92
10.20
9.48
8.76
8.04
7.32
6.48
3.36
3.72
3.96
4.20
4.32
4.44
4.56
4.68
4.80
4.92
14.64
13.80
12.96
12.12
11.40
10.56
9.84
9.12
8.40
7.68
3.96
4.20
4.56
4.80
4.92
5.16
5.28
5.40
5.64
5.76
-5
16.08
15.36
14.52
13.68
12.84
11.88
11.04
10.08
9.12
8.16
3.48
3.84
4.20
4.44
4.68
4.92
5.16
5.28
5.40
5.52
18.36
17.40
16.32
15.36
14.40
13.44
12.48
11.52
10.68
9.72
4.08
4.44
4.80
5.16
5.40
5.64
5.88
6.12
6.36
6.48
0
19.92
18.96
18.00
16.92
15.84
14.76
13.68
12.60
11.40
10.20
3.48
3.96
4.32
4.80
5.04
5.40
5.64
5.88
6.12
6.24
22.92
21.60
20.28
19.08
17.88
16.68
15.48
14.40
13.32
12.24
4.20
4.68
5.04
5.40
5.76
6.12
6.48
6.72
7.08
7.32
Evaporating Temperature oCCondensingTemperature
oC 5
24.48
23.28
22.08
20.76
19.44
18.12
16.80
15.36
14.04
12.60
3.36
3.96
4.44
4.92
5.40
5.76
6.12
6.36
6.72
6.96
28.08
26.52
24.96
23.40
21.96
20.52
19.08
17.64
16.32
15.00
4.08
4.68
5.16
5.76
6.12
6.60
6.96
7.32
7.68
8.04
7
26.52
25.20
23.88
22.44
21.00
19.56
18.12
16.68
15.12
13.56
3.24
3.84
4.44
4.92
5.40
5.88
6.24
6.60
6.96
7.20
30.48
28.68
27.00
25.32
23.76
22.20
20.64
19.08
17.64
16.20
4.08
4.68
5.28
5.76
6.24
6.72
7.20
7.56
7.92
8.40
10
28.20
26.76
25.20
23.64
21.96
20.28
18.72
16.92
15.24
3.72
4.44
4.92
5.52
6.00
6.48
6.84
7.20
7.56
32.28
30.36
28.44
26.64
24.84
23.16
21.48
19.80
18.12
4.68
5.28
5.88
6.48
6.96
7.44
7.92
8.40
8.76
12.5
30.96
29.28
27.60
25.92
24.12
22.32
20.52
18.60
16.80
3.60
4.32
4.92
5.52
6.12
6.60
7.08
7.44
7.80
35.40
33.36
31.20
29.28
27.24
25.44
23.52
21.72
19.92
4.56
5.28
5.88
6.48
7.08
7.68
8.16
8.64
9.12
-20
7.80
7.44
7.08
6.60
6.24
5.76
5.28
4.44
3.96
3.36
3.00
3.12
3.24
3.36
3.36
3.48
3.48
3.48
3.60
3.60
8.76
8.28
7.80
7.32
6.84
6.36
5.88
4.80
4.32
3.84
3.48
3.60
3.84
3.96
3.96
4.08
4.08
4.20
4.20
4.20
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Liquid subcooling 0K
23
2S Series
Dimensional Drawing
2SCW-0550/055E - 2SKW-0750/075E
SL – Suction line (rotalock) DL – Discharge line (rotalock)
4. Plug- Crankcase heater 3/8”-18NPSL
5. Plug- oil charge 1/4”-18NPTF
1. Plug -low pressure connection 1/8”-27NPTF
2. Plug- high pressure connection 1/8”-27NPTF
3. Oil Pressure Switch Sensor Connection 3/4”-16UNF
44.5
SL-AIR
SL
45o
87
128 A34
L
101
133
5
80
118 83B
W
2
DL
1112
3
4
251
H35
5
30
Model
2SCW-0550/2SCW-055E
2SKW-0750/2SKW-075E
SL Ø(Suction Line)
1 1/8
1 1/8
DL Ø(Discharge Line)
7/8
7/8
A(Mounting Length)
295 mm
295 mm
B(Mounting Length)
279 mm
279 mm
L(Length)
553 mm
553 mm
W(Width)
330 mm
330 mm
H(Height)
395 mm
395 mm
24
2S Series
Wiring Diagram
Terminal Jumper Schematics
Note:The thermistor assembled in the compressor can only be connected to terminal 1 & 2 of module A1, see the wiring diagram. The max. measuring voltage of the thermistor is 3V, the cold resistance of the thermistor is≤750
In A1 there is another 1 and 2,11,12, 14 (Terminals of Motor Protection Module)
Color codeVT: violetOG: orangeGY: greyBN: brownBU: bluePK: pink
Electrical Diagram CodingA1: Motor protection moduleA2: Oil differential pressure switch OPS2A3: ThermistorsA5: Terminal box B1: Thermostat D1: Operating Recognition ConnectionPE: Grounding Connection
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
1(U) 2(V) 3(W)
7(Z) 8(X) 9(Y)
L1 L2 L3
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
Direct-on-line startY-
Direct-on-line start Direct-on-line startY
Star-delta-motorY-
Code E
Jumper Connection
U V W
Z X Y
U V W
Z X Y
U VW
Z
X
Y
7
891011
12
6 5 4 3
2
R2
K1
F6
L N 1 2 12 14 11
A1
1
F7 F8
L1 L2 L3
A5
A3
PE
A2
Control Circuit220-240V 50/60Hz
L1 N
Q1 F1A1
1114
12L N
K1 H1
H21011122 1
BU BN VT OG GY PKN L1 D1
A5
A2
K5
F3
B1
K1
PK
GY
OG
VT
BN
BUN
L1
D1
K5: Fan motor contact coilN: Neutral connectionQ1: Main SwitchR2: Crankcase heater1-12: Accessory Connectors
F1: Fuse for control circuitF3: H/L pressure switches F6, F7, F8: Fuses for main circuitH1, H2: Alarm indicatorK1: Compressor contactor coilL1, L2, L3: Voltage connection 380-420V-3-50/60Hz-Y 220-240V-3-50/60Hz-Delta
25
2S Series
Motor Current Data (A)
-45
5.3/6.7
6.0/7.6
7.5/9.4
9.2/15.9
10.4/13.2
12.9/16.2
-40
5.9/7.4
6.4/8.1
8.0/10.1
10.2/17.6
11.1/14.0
13.8/17.4
-35
6.5/8.2
8.0/10.0
6.5/8.2
7.0/8.8
8.7/11.0
11.2/14.1
13.8/17.4
11.2/19.4
12.1/15.3
15.1/19.0
-30
7.1/9.0
8.9/11.2
7.1/8.9
7.7/9.7
9.5/12.0
12.3/15.5
15.4/19.4
12.2/21.2
13.3/16.7
16.4/20.7
-25
7.8/9.8
9.7/12.3
7.7/9.71
8.4/10.6
10.4/13.1
13.5/17.0
16.8/21.2
13.3/23.0
14.6/18.4
18.0/22.6
-20
8.5/10.7
10.5/13.2
9.2/11.6
11.3/14.3
6.4/7.6
8.2/9.9
14.6/18.4
18.2/22.9
15.9/20.1
19.6/24.7
11.0/13.4
14.3/17.3
-15
9.1/11.4
11.2/14.1
10.0/12.6
12.3/15.5
6.7/8.1
8.6/10.4
15.7/19.8
19.4/24.5
17.2/21.7
21.3/26.8
11.6/14.1
14.9/18.1
-10
9.7/12.2
11.9/15.0
10.7/13.4
13.3/16.7
7.1/8.6
9.0/10.8
16.7/21.0
20.6/25.9
18.5/23.3
22.9/28.9
12.3/15.0
15.6/19.0
-5
10.1/12.8
12.5/15.8
11.3/14.2
14.2/17.9
7.5/9.0
9.5/11.3
17.5/22.1
21.6/27.3
19.5/24.6
24.6/30.9
13.0/15.8
16.3/19.8
2SCW-0550
2SKW-0750
2SCW-0550 Air
2SCW-055E
2SKW-075E
2SCW-055E
2SKW-075E
2SCW-0550
2SKW-0750
2SCW-0550 Air
2SCW-055E
2SKW-075E
2SCW-055E
2SKW-075E
R22 (400V-3-50 Hz/380V-3-60 Hz) tc=40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
R404A/507 (400V-3-50Hz/380V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 10 12.5
Star Connection (Y)
R134a (400V-3-50Hz/380V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 10 12.5
Star Connection (Y)
R22 (230V-3-50Hz/230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 10 12.5
Delta Connection
R404A/507 (230V-3-50Hz/230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 10 12.5
Delta Connection
R134a (230V-3-50Hz/230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 10 12.5
Delta Connection
0
7.9/9.4
9.8/11.8
13.6/16.5
17.0/20.7
5
8.1/9.8
10.2/12.2
14.1/17.1
17.6/21.4
7
8.2/9.9
10.3/12.4
14.2/17.3
17.9/21.7
10
8.3/10.0
10.5/12.6
14.4/17.5
18.2/22.1
12.5
8.4/10.0
10.6/12.8
14.5/17.6
18.4/22.3
26
3S Series
Model Nomenclature & Bill of Materials
X X X X - X X X X - X X X - X X X
Design Series
Oil TypeCode Description E Ester oil 0 Mineral oil
Model Variation
Bill of Materials
Displacement and Valve Plate
Motor Rating Power Code HP 1000 10 1500 15
Compressor Family SeriesCode Description
3 3 Cylinder
Compressor Motor TypeCode Phase Motor Type
T Three Single Voltage E Three Dual voltage
Compressor Motor ProtectionCode Type F Internal Inherent protector W Motor protection with Thermistors and module in the terminal box
Electrical Code Code Voltage Ph Hz D 380/420 Y 3 50 460 Y 3 60 K 220-240 ∆ 3 60 380-420 Y 3 60
3S SeriesMounting PartsRotalock/Service ValveCrankcase HeaterElectronic Oil Pressure Switch (OPS2)Motor Protection ModuleDischarge Temp Control Valve (DTC)
Bill of Materials (BOM)
Note: * To be ordered separately DTC valve part number 998-0011-00
202√√√√√
*accessory
27
3S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10
15
20
25
30
35
40
45
50
55
10
15
20
25
30
35
40
45
50
55
10
15
20
25
30
35
40
45
50
55
10
15
20
25
30
35
40
45
50
55
Model
3SC1-1000
3SS1-1500
-40
6.50
5.90
5.40
4.80
4.30
3.80
3.30
2.80
2.30
1.90
3.10
3.20
3.30
3.30
3.30
3.30
3.20
3.20
3.10
2.90
8.70
7.90
7.20
6.50
5.80
5.10
4.50
3.80
3.30
2.70
4.30
4.40
4.50
4.60
4.60
4.60
4.50
4.50
4.40
4.30
-35
8.60
8.00
7.30
6.70
6.00
5.40
4.80
4.30
3.70
3.20
3.50
3.70
3.80
3.80
3.90
3.90
3.90
3.90
3.90
3.90
11.70
10.80
9.90
9.00
8.20
7.40
6.70
6.00
5.30
4.60
4.90
5.10
5.20
5.30
5.40
5.50
5.60
5.60
5.60
5.60
-30
11.40
10.60
9.80
9.00
8.20
7.40
6.70
6.10
5.40
4.70
3.90
4.10
4.20
4.40
4.50
4.60
4.60
4.70
4.70
4.80
15.20
14.20
13.20
12.20
11.20
10.20
9.20
8.50
7.60
6.80
5.50
5.80
5.90
6.10
6.30
6.40
6.60
6.70
6.80
6.90
-25
14.60
13.70
12.80
11.90
10.90
10.00
9.00
8.20
7.30
6.60
4.30
4.50
4.70
4.90
5.00
5.20
5.30
5.40
5.60
5.70
19.50
18.30
17.10
15.90
14.70
13.50
12.40
11.30
10.20
9.50
6.20
6.40
6.70
6.90
7.10
7.30
7.50
7.70
7.90
8.20
Evaporating Temperature oCCondensingTemperature
oC
Notes:
-20
18.40
17.30
16.30
15.20
14.10
13.00
11.90
10.90
9.80
8.80
4.80
5.00
5.20
5.40
5.60
5.80
6.00
6.20
6.40
6.60
24.50
23.00
21.60
20.30
18.90
17.50
16.10
14.80
13.60
12.30
6.80
7.10
7.40
7.70
8.00
8.30
8.50
8.80
9.10
9.40
-15
22.80
21.60
20.30
19.10
17.90
16.60
15.40
14.10
12.80
11.60
5.20
5.40
5.70
6.00
6.20
6.50
6.70
7.00
7.30
7.50
30.30
28.60
27.00
25.30
23.70
22.20
20.60
19.00
17.50
16.00
7.60
7.90
8.30
8.60
8.90
9.20
9.60
9.90
10.30
10.70
-10
27.90
26.50
25.10
23.60
22.20
20.80
19.40
17.90
16.50
15.00
5.60
5.90
6.20
6.50
6.80
7.10
7.50
7.80
8.10
8.50
37.00
35.00
33.10
31.20
29.30
27.50
25.70
23.90
22.20
20.30
8.40
8.80
9.10
9.50
9.90
10.30
10.70
11.10
11.50
12.00
-5
33.80
32.20
30.50
28.90
27.20
25.60
23.90
22.30
20.60
19.00
6.10
6.40
6.80
7.10
7.50
7.80
8.20
8.60
9.00
9.40
44.60
42.40
40.20
37.90
35.80
33.60
31.50
29.40
27.40
25.40
9.30
9.70
10.20
10.60
11.00
11.40
11.90
12.30
12.80
13.30
-45
4.70
4.20
3.80
3.30
2.90
2.40
2.00
1.60
2.70
2.80
2.80
2.80
2.70
2.70
2.50
2.40
6.30
5.70
5.00
4.40
3.80
3.20
2.60
2.10
3.70
3.80
3.80
3.70
3.70
3.60
3.50
3.30
1. Suction Gas Temperature 20°C2. Liquid subcooling 0K3. Suction Superheat 20K 4. Suction Superheat 20K + FAN5. Suction Gas Temperature 20°C + FAN + DTC
28
3S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10
15
20
25
30
35
40
45
50
55
60
62
10
15
20
25
30
35
40
45
50
55
60
62
10
15
20
25
30
35
40
45
50
55
60
62
10
15
20
25
30
35
40
45
50
55
60
62
Model
3SCH-1000
3SSH-1500
-20
17.30
16.20
15.20
14.30
13.40
12.50
11.70
10.50
9.70
4.30
4.70
5.10
5.40
5.70
6.00
6.30
6.50
6.70
23.90
22.50
21.20
20.00
18.70
17.60
16.40
14.90
13.80
6.20
6.80
7.30
7.70
8.00
8.40
8.60
8.90
9.10
-15
21.70
20.40
19.20
18.10
16.90
15.90
14.80
13.90
12.50
11.60
10.70
4.40
4.90
5.30
5.80
6.20
6.50
6.90
7.20
7.50
7.70
8.00
29.70
28.00
26.40
24.90
23.40
22.00
20.60
19.30
17.60
16.30
15.00
6.40
7.10
7.70
8.20
8.70
9.10
9.50
9.90
10.30
10.60
11.10
-10
27.00
25.40
24.00
22.50
21.20
19.90
18.60
17.40
16.20
15.10
13.70
13.20
4.30
4.90
5.50
6.00
6.50
7.00
7.40
7.80
8.20
8.60
8.90
9.10
36.50
34.50
32.60
30.80
29.00
27.30
25.60
24.00
22.40
20.80
19.00
18.40
6.50
7.30
8.00
8.70
9.30
9.80
10.30
10.80
11.30
11.80
12.40
12.60
-5
33.20
31.40
29.60
27.90
26.20
24.60
23.00
21.50
20.10
18.70
17.40
16.80
4.20
4.90
5.50
6.10
6.80
7.30
7.90
8.40
8.90
9.40
9.90
10.10
44.40
42.10
39.90
37.70
35.50
33.40
31.40
29.40
27.50
25.60
23.80
23.10
6.40
7.30
8.20
9.00
9.70
10.40
11.10
11.70
12.40
13.00
13.70
14.00
Evaporating Temperature oCCondensingTemperature
oC 0
38.30
36.20
34.10
32.10
30.20
28.30
26.50
24.70
23.00
21.30
20.70
4.70
5.40
6.20
6.90
7.60
8.30
8.90
9.50
10.20
10.80
11.00
50.90
48.30
45.70
43.10
40.60
38.20
35.80
33.50
31.20
29.00
28.10
7.20
8.30
9.20
10.10
10.90
11.70
12.50
13.30
14.10
15.00
15.30
5
43.80
41.40
39.00
36.70
34.40
32.20
30.10
28.00
26.00
25.20
5.20
6.10
6.90
7.70
8.50
9.30
10.10
10.90
11.60
11.90
58.00
54.90
51.90
48.90
46.00
43.20
40.40
37.70
35.00
33.90
8.10
9.20
10.30
11.30
12.30
13.30
14.20
15.20
16.20
16.60
7
47.20
44.60
42.10
39.60
37.10
34.80
32.50
30.20
28.10
27.20
5.10
6.00
6.90
7.80
8.60
9.50
10.30
11.10
11.90
12.20
62.20
59.00
55.70
52.60
49.50
46.40
43.50
40.50
37.60
36.50
8.10
9.20
10.40
11.40
12.50
13.50
14.50
15.60
16.60
17.10
10
49.80
47.00
44.20
41.50
38.90
36.40
33.90
31.40
30.50
5.80
6.80
7.80
8.70
9.60
10.60
11.50
12.30
12.70
65.50
61.90
58.50
55.00
51.70
48.40
45.10
41.90
40.70
9.10
10.40
11.60
12.70
13.90
15.00
16.10
17.30
17.80
-25
13.60
12.70
11.90
11.20
10.50
9.70
8.60
4.20
4.50
4.80
5.00
5.30
5.50
5.60
19.10
18.00
16.90
15.80
14.80
13.80
12.40
5.90
6.40
6.80
7.10
7.30
7.60
7.70
Notes:1. Suction Gas Temperature 20°C2. SH 20K3. Liquid subcooling 0K
12.5
54.50
51.40
48.40
45.50
42.70
39.90
37.20
34.50
33.50
5.70
6.70
7.70
8.80
9.70
10.80
11.70
12.70
13.10
71.30
67.50
63.70
60.00
56.40
52.80
49.20
45.80
44.40
9.00
10.40
11.60
12.90
14.10
15.30
16.60
17.90
18.40
29
3S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
Model
3SC1-100E
3SS1-150E
-40
6.20
5.60
5.00
4.40
3.40
2.90
2.40
1.90
3.50
3.50
3.50
3.50
3.50
3.50
3.40
3.40
8.90
8.10
7.30
6.60
5.30
4.60
3.90
3.20
5.00
5.10
5.10
5.20
5.20
5.30
5.40
5.60
-35
8.40
7.70
6.90
6.20
5.50
4.30
3.60
2.90
4.10
4.20
4.30
4.30
4.30
4.30
4.30
4.20
11.80
10.90
9.90
9.00
8.10
6.60
5.70
4.90
5.80
5.90
6.00
6.10
6.20
6.20
6.40
6.50
-30
11.20
10.30
9.30
8.40
7.50
6.60
5.70
4.20
4.80
4.90
5.00
5.10
5.20
5.20
5.20
5.20
15.30
14.10
13.00
11.90
10.80
9.80
8.70
6.80
6.70
6.80
7.00
7.10
7.20
7.30
7.50
7.60
-25
14.50
13.40
12.20
11.10
9.90
8.80
7.70
6.60
5.40
5.60
5.80
5.90
6.00
6.10
6.20
6.20
19.40
18.00
16.60
15.30
14.00
12.70
11.40
10.10
7.40
7.70
8.00
8.20
8.30
8.50
8.70
8.90
Evaporating Temperature oCCondensingTemperature
oC -20
18.40
17.00
15.70
14.30
12.90
11.50
10.10
8.70
5.90
6.20
6.50
6.70
6.90
7.10
7.20
7.30
24.20
22.50
20.90
19.30
17.60
16.10
14.50
12.90
8.10
8.60
8.90
9.20
9.50
9.80
10.00
10.30
-15
23.00
21.30
19.70
18.00
16.30
14.60
12.90
11.30
6.40
6.80
7.20
7.50
7.80
8.00
8.20
8.30
29.80
27.80
25.80
23.80
21.90
20.00
18.10
16.20
8.80
9.30
9.90
10.30
10.70
11.10
11.40
11.70
-10
28.20
26.30
24.30
22.30
20.30
18.30
16.30
14.30
6.80
7.40
7.80
8.20
8.60
8.90
9.20
9.40
36.30
33.90
31.50
29.20
26.80
24.50
22.20
19.90
9.20
10.00
10.70
11.30
11.90
12.40
12.80
13.20
-5
34.20
31.90
29.60
27.30
24.90
22.50
20.10
17.80
7.10
7.80
8.40
8.90
9.40
9.80
10.20
10.50
43.70
40.90
38.10
35.30
32.50
29.70
27.00
24.30
9.50
10.60
11.40
12.20
12.90
13.60
14.20
14.80
-45
4.40
3.90
3.10
2.60
2.20
1.80
2.80
2.80
2.80
2.80
2.80
2.70
6.60
5.90
4.80
4.10
3.40
2.80
4.30
4.30
4.30
4.30
4.40
4.50
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan4. Liquid subcooling 0K
R404A /507R404A /507
30
3S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
Model
3SCH-100E
3SSH-150E
-25
14.80
13.70
12.70
11.60
10.50
9.40
8.40
7.30
5.30
5.60
5.80
6.00
6.10
6.20
6.20
6.20
20.40
18.90
17.50
16.10
14.70
13.30
11.90
10.60
7.50
7.90
8.20
8.50
8.70
8.90
9.00
9.00
-20
18.60
17.30
16.00
14.80
13.50
12.20
10.90
9.50
5.80
6.10
6.40
6.70
6.90
7.10
7.20
7.30
25.30
23.60
21.90
20.20
18.60
16.90
15.20
13.60
8.10
8.60
9.00
9.40
9.80
10.10
10.30
10.50
-15
23.10
21.60
20.00
18.50
16.90
15.30
13.70
12.10
6.20
6.60
7.00
7.40
7.70
7.90
8.20
8.30
31.20
29.20
27.10
25.10
23.10
21.10
19.00
17.00
8.60
9.30
9.80
10.40
10.80
11.30
11.60
11.90
-10
28.40
26.50
24.70
22.80
20.90
18.90
17.00
15.00
6.40
7.00
7.50
8.00
8.40
8.80
9.10
9.30
38.00
35.60
33.20
30.80
28.30
25.90
23.40
20.90
9.10
9.80
10.60
11.20
11.80
12.40
12.80
13.30
Evaporating Temperature oCCondensingTemperature
oC -5
34.50
32.30
30.00
27.70
25.40
23.10
20.80
18.40
6.60
7.30
7.90
8.50
9.10
9.50
10.00
10.30
46.00
43.10
40.20
37.30
34.40
31.40
28.50
25.50
9.50
10.40
11.20
12.00
12.70
13.40
14.00
14.60
0
41.50
38.90
36.10
33.40
30.70
27.90
25.10
22.20
6.60
7.40
8.20
8.90
9.60
10.20
10.80
11.30
55.10
51.70
48.30
44.80
41.30
37.80
34.30
30.70
9.80
10.80
11.80
12.70
13.50
14.30
15.10
15.80
5
49.50
46.30
43.10
39.90
36.60
33.30
30.00
26.70
6.40
7.40
8.30
9.20
10.00
10.80
11.40
12.10
65.50
61.50
57.40
53.40
49.20
45.10
40.90
36.70
10.00
11.10
12.20
13.30
14.30
15.20
16.10
17.00
7
52.90
49.50
46.10
42.70
39.20
35.70
32.20
28.60
6.20
7.30
8.30
9.20
10.10
10.90
11.70
12.30
70.00
65.70
61.40
57.10
52.70
48.30
43.80
39.30
10.00
11.20
12.40
13.50
14.60
15.60
16.50
17.40
-30
11.60
10.70
9.80
8.90
8.00
7.10
6.20
4.80
5.00
5.10
5.20
5.30
5.30
5.30
16.30
15.00
13.80
12.50
11.40
10.20
9.00
6.80
7.10
7.30
7.50
7.60
7.70
7.70
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
R404A /507R404A /507
31
3S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
Model
3SC1-100E
3SS1-150E
-15
11.40
10.80
10.20
9.50
8.90
8.20
7.50
6.80
6.20
4.90
3.80
3.90
4.10
4.20
4.30
4.40
4.40
4.50
4.50
4.40
14.90
14.20
13.30
12.50
11.60
10.80
9.90
9.10
8.40
6.80
4.90
5.10
5.30
5.50
5.70
5.80
5.90
6.00
6.00
6.10
-10
14.50
13.80
13.00
12.20
11.30
10.50
9.60
8.80
8.00
7.30
4.10
4.30
4.50
4.70
4.80
4.90
5.10
5.10
5.20
5.30
19.20
18.10
17.00
16.00
14.90
13.80
12.70
11.70
10.80
9.90
5.30
5.60
5.90
6.10
6.40
6.60
6.70
6.90
7.10
7.20
-5
18.40
17.40
16.40
15.40
14.30
13.20
12.20
11.20
10.30
9.40
4.50
4.70
4.90
5.10
5.30
5.50
5.70
5.80
6.00
6.10
24.20
22.90
21.50
20.10
18.70
17.40
16.10
14.80
13.60
12.50
5.70
6.10
6.40
6.70
7.00
7.30
7.60
7.80
8.10
8.30
0
23.00
21.70
20.40
19.20
17.90
16.60
15.30
14.10
12.90
11.90
4.80
5.10
5.40
5.60
5.90
6.10
6.30
6.60
6.80
7.00
30.30
28.60
26.80
25.10
23.40
21.70
20.00
18.50
17.00
15.60
6.00
6.50
6.90
7.30
7.70
8.10
8.40
8.70
9.10
9.40
Evaporating Temperature oCCondensingTemperature
oC 5
28.40
26.90
25.30
23.60
22.00
20.50
19.00
17.50
16.10
14.80
5.10
5.40
5.80
6.10
6.40
6.70
7.00
7.30
7.60
7.80
37.50
35.30
33.10
31.00
28.80
26.70
24.70
22.80
21.00
19.30
6.30
6.80
7.30
7.80
8.30
8.70
9.20
9.60
10.10
10.50
7
30.80
29.10
27.40
25.70
23.90
22.20
20.60
19.00
17.50
16.10
5.20
5.60
5.90
6.30
6.60
6.90
7.30
7.60
7.90
8.20
40.70
38.30
36.00
33.60
31.30
29.00
26.80
24.70
22.70
20.90
6.40
7.00
7.50
8.00
8.50
9.00
9.50
9.90
10.40
10.90
10
32.80
30.90
28.90
27.00
25.10
23.20
21.50
19.80
18.20
5.80
6.10
6.50
6.90
7.30
7.70
8.00
8.40
8.70
43.20
40.50
37.90
35.30
32.70
30.20
27.90
25.60
23.50
7.10
7.70
8.30
8.80
9.40
9.90
10.50
11.00
11.50
12.5
36.20
34.10
31.90
29.80
27.70
25.70
23.70
21.80
20.10
5.90
6.30
6.70
7.20
7.60
8.00
8.40
8.80
9.20
47.60
44.70
41.70
38.90
36.00
33.30
30.70
28.20
25.80
7.20
7.80
8.50
9.10
9.70
10.30
10.90
11.40
12.00
-20
8.70
8.30
7.90
7.40
6.90
6.30
5.70
4.60
4.10
3.60
3.40
3.60
3.70
3.70
3.80
3.80
3.80
3.80
3.70
3.70
11.50
11.00
10.30
9.70
9.00
8.30
7.60
6.20
5.60
5.00
4.40
4.60
4.70
4.90
4.90
5.00
5.00
5.10
5.00
5.00
Notes:1.Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3.Liquid subcooling 0K
32
3S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10
15
20
25
30
35
40
45
50
55
10
15
20
25
30
35
40
45
50
55
10
15
20
25
30
35
40
45
50
55
10
15
20
25
30
35
40
45
50
55
Model
3SC1-1000
3SS1-1500
-40
7.60
7.00
6.30
5.70
5.10
4.50
3.90
3.30
2.80
2.30
3.80
3.90
3.90
4.00
4.00
4.00
3.90
3.80
3.70
3.50
10.30
9.40
8.50
7.70
6.80
6.00
5.30
4.50
3.80
3.20
5.20
5.30
5.40
5.50
5.50
5.50
5.40
5.40
5.30
5.20
-35
10.20
9.50
8.70
7.90
7.10
6.40
5.70
5.00
4.40
3.70
4.20
4.40
4.50
4.60
4.70
4.70
4.70
4.70
4.70
4.60
13.80
12.80
11.70
10.70
9.70
8.70
7.90
7.00
6.20
5.40
5.90
6.10
6.30
6.40
6.50
6.60
6.70
6.70
6.80
6.80
-30
13.40
12.50
11.60
10.60
9.70
8.80
7.90
7.20
6.30
5.60
4.70
4.90
5.10
5.20
5.40
5.50
5.60
5.60
5.70
5.70
18.00
16.80
15.60
14.40
13.20
12.00
10.90
10.00
9.00
8.10
6.60
6.90
7.10
7.30
7.50
7.70
7.90
8.00
8.20
8.30
-25
17.20
16.10
15.10
14.00
12.90
11.80
10.70
9.60
8.70
7.80
5.20
5.40
5.70
5.90
6.00
6.20
6.40
6.50
6.70
6.80
23.00
21.50
20.10
18.80
17.30
15.90
14.60
13.30
12.10
11.20
7.40
7.70
8.00
8.30
8.60
8.80
9.10
9.30
9.50
9.80
Evaporating Temperature oCCondensingTemperature
oC
Notes:
-20
21.70
20.40
19.20
17.90
16.70
15.30
14.10
12.80
11.60
10.40
5.70
6.00
6.20
6.50
6.80
7.00
7.20
7.50
7.70
7.90
28.90
27.20
25.50
23.90
22.30
20.60
19.00
17.50
16.00
14.60
8.20
8.60
8.90
9.30
9.60
9.90
10.30
10.60
11.00
11.30
-15
26.90
25.50
24.00
22.50
21.10
19.60
18.20
16.60
15.20
13.70
6.20
6.50
6.80
7.20
7.50
7.80
8.10
8.40
8.70
9.00
35.70
33.80
31.80
29.90
28.00
26.10
24.30
22.30
20.60
18.90
9.10
9.50
9.90
10.30
10.70
11.10
11.50
11.90
12.40
12.80
-10
33.00
31.30
29.60
27.90
26.20
24.50
22.80
21.10
19.50
17.70
6.80
7.10
7.50
7.80
8.20
8.60
9.00
9.40
9.80
10.20
43.60
41.40
39.10
36.80
34.60
32.40
30.30
28.20
26.20
23.90
10.10
10.60
11.00
11.50
11.90
12.40
12.80
13.30
13.80
14.40
-5
39.90
38.00
36.00
34.10
32.10
30.20
28.20
26.30
24.30
22.40
7.30
7.70
8.10
8.50
9.00
9.40
9.90
10.40
10.80
11.40
52.70
50.00
47.40
44.80
42.20
39.70
37.20
34.70
32.30
30.00
11.20
11.70
12.20
12.70
13.20
13.70
14.20
14.80
15.40
16.00
-45
5.60
5.00
4.50
3.90
3.40
2.90
2.40
1.90
3.30
3.40
3.40
3.40
3.30
3.20
3.00
2.90
7.40
6.70
5.90
5.20
4.40
3.70
3.10
2.40
4.50
4.50
4.50
4.50
4.40
4.30
4.20
4.00
1. Suction Gas Temperature 20°C2. Liquid subcooling 0K3. Suction Superheat 20K 4. Suction Superheat 20K + FAN5. Suction Gas Temperature 20°C + FAN + DTC
33
3S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10
15
20
25
30
35
40
45
50
55
60
62
10
15
20
25
30
35
40
45
50
55
60
62
10
15
20
25
30
35
40
45
50
55
60
62
10
15
20
25
30
35
40
45
50
55
60
62
Model
3SCH-1000
3SSH-1500
-20
20.40
19.20
18.00
16.90
15.80
14.80
13.80
12.40
11.50
5.20
5.70
6.10
6.50
6.90
7.20
7.50
7.80
8.00
28.20
26.60
25.00
23.50
22.10
20.70
19.40
17.60
16.20
7.40
8.10
8.70
9.20
9.70
10.10
10.40
10.70
11.00
-15
25.60
24.10
22.70
21.30
20.00
18.70
17.50
16.40
14.80
13.70
12.70
5.30
5.90
6.40
6.90
7.40
7.80
8.20
8.60
9.00
9.30
9.60
35.00
33.10
31.20
29.40
27.60
26.00
24.30
22.80
20.70
19.20
17.70
7.70
8.50
9.20
9.90
10.50
11.00
11.40
11.90
12.30
12.80
13.30
-10
31.80
30.00
28.30
26.60
25.00
23.40
21.90
20.50
19.10
17.80
16.10
15.60
5.20
5.90
6.60
7.20
7.80
8.40
8.90
9.40
9.90
10.30
10.80
10.90
43.00
40.70
38.50
36.30
34.20
32.20
30.20
28.30
26.40
24.60
22.30
21.60
7.80
8.70
9.60
10.40
11.10
11.80
12.40
13.00
13.60
14.20
14.90
15.10
-5
39.20
37.00
34.90
32.90
30.90
29.00
27.20
25.40
23.70
22.00
20.50
19.90
5.00
5.80
6.60
7.40
8.10
8.80
9.50
10.10
10.70
11.30
11.90
12.10
52.40
49.70
47.00
44.40
41.90
39.50
37.10
34.70
32.50
30.20
28.10
27.20
7.70
8.80
9.80
10.80
11.70
12.50
13.30
14.10
14.80
15.60
16.40
16.80
Evaporating Temperature oCCondensingTemperature
oC 0
45.20
42.70
40.30
37.90
35.60
33.40
31.20
29.10
27.10
25.10
24.40
5.60
6.50
7.40
8.30
9.10
9.90
10.70
11.50
12.20
12.90
13.20
60.10
57.00
53.90
50.90
47.90
45.10
42.30
39.50
36.80
34.20
33.20
8.70
9.90
11.10
12.10
13.10
14.10
15.00
16.00
17.00
17.90
18.40
5
51.70
48.80
46.00
43.30
40.60
38.00
35.50
33.00
30.70
29.70
6.30
7.30
8.30
9.30
10.30
11.20
12.10
13.00
13.90
14.30
68.40
64.80
61.20
57.70
54.30
51.00
47.70
44.40
41.30
40.00
9.80
11.10
12.40
13.60
14.80
15.90
17.10
18.20
19.40
19.90
7
55.70
52.60
49.60
46.70
43.80
41.00
38.30
35.70
33.10
32.10
6.10
7.20
8.30
9.30
10.40
11.40
12.40
13.30
14.30
14.70
73.40
69.60
65.80
62.10
58.40
54.80
51.30
47.80
44.40
43.10
9.70
11.10
12.40
13.70
15.00
16.20
17.40
18.70
20.00
20.50
10
58.80
55.40
52.20
49.00
45.90
42.90
40.00
37.10
36.00
7.00
8.20
9.30
10.50
11.60
12.70
13.70
14.80
15.20
77.30
73.10
69.00
64.90
61.00
57.10
53.20
49.50
48.00
11.00
12.50
13.90
15.30
16.60
18.00
19.40
20.80
21.30
-25
16.00
15.00
14.10
13.20
12.30
11.50
10.20
5.00
5.40
5.70
6.10
6.30
6.50
6.70
22.50
21.20
19.90
18.70
17.50
16.30
14.70
7.10
7.70
8.10
8.50
8.80
9.10
9.30
Notes:1. Suction Gas Temperature 20°C2. SH 20K3. Liquid subcooling 0K
12.5
64.30
60.70
57.10
53.70
50.30
47.00
43.80
40.70
39.50
6.80
8.10
9.30
10.50
11.70
12.90
14.10
15.20
15.70
84.20
79.70
75.20
70.80
66.50
62.30
58.10
54.00
52.40
10.90
12.40
14.00
15.50
16.90
18.40
19.90
21.40
22.00
34
3S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
Model
3SC1-100E
3SS1-150E
-40
7.30
6.60
5.90
5.20
4.00
3.40
2.80
2.30
4.20
4.20
4.20
4.20
4.20
4.20
4.10
4.00
10.60
9.60
8.70
7.80
6.30
5.40
4.60
3.80
6.00
6.10
6.10
6.20
-35
10.00
9.10
8.20
7.30
6.50
5.00
4.20
3.50
4.90
5.00
5.10
5.20
5.20
5.20
5.10
5.10
13.90
12.80
11.70
10.70
9.60
7.80
6.80
5.80
7.00
7.10
7.20
7.30
7.40
-30
13.20
12.10
11.00
9.90
8.90
7.80
6.80
4.90
5.70
5.90
6.00
6.10
6.20
6.20
6.30
6.20
18.00
16.70
15.30
14.10
12.80
11.60
10.30
8.00
8.00
8.20
8.40
8.50
8.70
8.80
9.00
-25
17.10
15.80
14.40
13.10
11.80
10.40
9.10
7.80
6.40
6.70
6.90
7.10
7.30
7.40
7.40
7.50
22.80
21.20
19.60
18.00
16.50
15.00
13.40
11.90
8.90
9.30
9.60
9.80
10.00
10.20
10.50
10.70
Evaporating Temperature oCCondensingTemperature
oC -20
21.70
20.10
18.50
16.80
15.20
13.50
11.90
10.30
7.10
7.50
7.80
8.10
8.30
8.50
8.60
8.70
28.50
26.60
24.60
22.70
20.80
18.90
17.10
15.20
9.80
10.30
10.80
11.10
11.50
11.80
12.00
12.30
-15
27.10
25.10
23.20
21.20
19.20
17.20
15.30
13.30
7.70
8.20
8.60
9.00
9.30
9.60
9.80
10.00
35.20
32.80
30.50
28.10
25.80
23.50
21.30
19.10
10.50
11.20
11.90
12.40
12.90
13.30
13.70
14.10
-10
33.30
31.00
28.70
26.30
23.90
21.50
19.20
16.80
8.20
8.80
9.40
9.90
10.30
10.70
11.10
11.30
42.80
40.00
37.20
34.40
31.70
28.90
26.20
23.50
11.10
12.00
12.90
13.60
14.20
14.80
15.40
15.90
-5
40.40
37.70
34.90
32.20
29.40
26.60
23.80
20.90
8.60
9.30
10.10
10.70
11.30
11.80
12.20
12.60
51.60
48.30
44.90
41.60
38.40
35.10
31.90
28.60
11.50
12.70
13.70
14.70
15.50
16.30
17.00
17.70
-45
5.20
4.60
3.70
3.10
2.60
2.10
3.40
3.40
3.40
3.40
3.30
3.20
7.80
6.90
5.70
4.80
4.10
3.30
5.10
5.10
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan4. Liquid subcooling 0K
R404A /507R404A /507
35
3S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
20
25
30
35
40
45
50
55
Model
3SCH-100E
3SSH-150E
-25
17.40
16.20
14.90
13.70
12.40
11.20
9.90
8.60
6.40
6.70
6.90
7.20
7.30
7.40
7.50
7.40
24.10
22.30
20.60
19.00
17.30
15.70
14.10
12.50
8.90
9.40
9.80
10.20
10.50
10.70
10.80
10.90
-20
21.90
20.40
18.90
17.40
15.90
14.40
12.80
11.30
6.90
7.40
7.70
8.00
8.30
8.50
8.60
8.70
29.90
27.90
25.90
23.90
21.90
20.00
18.00
16.00
9.70
10.30
10.90
11.40
11.80
12.10
12.40
12.60
-15
27.30
25.50
23.60
21.80
19.90
18.10
16.20
14.30
7.40
7.90
8.40
8.90
9.20
9.50
9.80
10.00
36.80
34.40
32.00
29.60
27.20
24.80
22.40
20.00
10.40
11.10
11.80
12.50
13.00
13.50
13.90
14.30
-10
33.50
31.30
29.10
26.90
24.60
22.30
20.00
17.70
7.70
8.40
9.00
9.60
10.10
10.60
10.90
11.20
44.90
42.00
39.20
36.30
33.40
30.50
27.60
24.70
10.90
11.80
12.70
13.50
14.20
14.80
15.40
15.90
Evaporating Temperature oCCondensingTemperature
oC -5
40.80
38.10
35.40
32.70
30.00
27.30
24.50
21.70
7.90
8.70
9.50
10.30
10.90
11.50
12.00
12.40
54.30
50.90
47.40
44.00
40.60
37.10
33.60
30.10
11.40
12.50
13.50
14.40
15.30
16.10
16.80
17.50
0
49.00
45.80
42.70
39.40
36.20
32.90
29.60
26.30
7.90
8.90
9.80
10.70
11.50
12.30
12.90
13.50
65.00
61.00
56.90
52.90
48.80
44.60
40.40
36.20
11.80
13.00
14.10
15.20
16.20
17.20
18.10
18.90
5
58.40
54.60
50.80
47.00
43.20
39.30
35.40
31.50
7.70
8.80
10.00
11.00
12.00
12.90
13.70
14.50
77.30
72.50
67.80
63.00
58.10
53.20
48.30
43.30
12.00
13.40
14.70
15.90
17.10
18.30
19.30
20.30
7
62.40
58.40
54.40
50.40
46.30
42.10
38.00
33.80
7.50
8.80
9.90
11.10
12.10
13.10
14.00
14.80
82.60
77.60
72.50
67.40
62.20
57.00
51.70
46.40
12.00
13.50
14.90
16.20
17.50
18.70
19.80
20.90
-30
13.60
12.60
11.60
10.50
9.40
8.40
7.40
5.80
6.00
6.10
6.30
6.30
6.30
6.30
19.20
17.70
16.20
14.80
13.40
12.00
10.70
8.10
8.50
8.80
9.00
9.10
9.20
9.20
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
R404A /507R404A /507
36
3S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
20
25
30
35
40
45
50
55
60
65
Model
3SC1-100E
3SS1-150E
-15
13.68
12.96
12.24
11.40
10.68
9.84
9.00
8.16
7.44
5.88
4.56
4.68
4.92
5.04
5.16
5.28
5.28
5.40
5.40
5.28
17.88
17.04
15.96
15.00
13.92
12.96
11.88
10.92
10.08
8.16
5.88
6.12
6.36
6.60
6.84
6.96
7.08
7.20
7.20
7.32
-10
17.40
16.56
15.60
14.64
13.56
12.60
11.52
10.56
9.60
8.76
4.92
5.16
5.40
5.64
5.76
5.88
6.12
6.12
6.24
6.36
23.04
21.72
20.40
19.20
17.88
16.56
15.24
14.04
12.96
11.88
6.36
6.72
7.08
7.32
7.68
7.92
8.04
8.28
8.52
8.64
-5
22.08
20.88
19.68
18.48
17.16
15.84
14.64
13.44
12.36
11.28
5.40
5.64
5.88
6.12
6.36
6.60
6.84
6.96
7.20
7.32
29.04
27.48
25.80
24.12
22.44
20.88
19.32
17.76
16.32
15.00
6.84
7.32
7.68
8.04
8.40
8.76
9.12
9.36
9.72
9.96
0
27.60
26.04
24.48
23.04
21.48
19.92
18.36
16.92
15.48
14.28
5.76
6.12
6.48
6.72
7.08
7.32
7.56
7.92
8.16
8.40
36.36
34.32
32.16
30.12
28.08
26.04
24.00
22.20
20.40
18.72
7.20
7.80
8.28
8.76
9.24
9.72
10.08
10.44
10.92
11.28
Evaporating Temperature oCCondensingTemperature
oC 5
34.08
32.28
30.36
28.32
26.40
24.60
22.80
21.00
19.32
17.76
6.12
6.48
6.96
7.32
7.68
8.04
8.40
8.76
9.12
9.36
45.00
42.36
39.72
37.20
34.56
32.04
29.64
27.36
25.20
23.16
7.56
8.16
8.76
9.36
9.96
10.44
11.04
11.52
12.12
12.60
7
36.96
34.92
32.88
30.84
28.68
26.64
24.72
22.80
21.00
19.32
6.24
6.72
7.08
7.56
7.92
8.28
8.76
9.12
9.48
9.84
48.84
45.96
43.20
40.32
37.56
34.80
32.16
29.64
27.24
25.08
7.68
8.40
9.00
9.60
10.20
10.80
11.40
11.88
12.48
13.08
10
39.36
37.08
34.68
32.40
30.12
27.84
25.80
23.76
21.84
6.96
7.32
7.80
8.28
8.76
9.24
9.60
10.08
10.44
51.84
48.60
45.48
42.36
39.24
36.24
33.48
30.72
28.20
8.52
9.24
9.96
10.56
11.28
11.88
12.60
13.20
13.80
12.5
43.44
40.92
38.28
35.76
33.24
30.84
28.44
26.16
24.12
7.08
7.56
8.04
8.64
9.12
9.60
10.08
10.56
11.04
57.12
53.64
50.04
46.68
43.20
39.96
36.84
33.84
30.96
8.64
9.36
10.20
10.92
11.64
12.36
13.08
13.68
14.40
-20
10.44
9.96
9.48
8.88
8.28
7.56
6.84
5.52
4.92
4.32
4.08
4.32
4.44
4.44
4.56
4.56
4.56
4.56
4.44
4.44
13.80
13.20
12.36
11.64
10.80
9.96
9.12
7.44
6.72
6.00
5.28
5.52
5.64
5.88
5.88
6.00
6.00
6.12
6.00
6.00
Notes:1.Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3.Liquid subcooling 0K
37
3S Series
Dimensional Drawing
SL – Suction line (rotalock) DL – Discharge line (rotalock)
8. Oil pressure connection 7/16”-20UNF
9. Oil Pressure Switch sensor connection 3/4”-16UNF
10. Plug -crankcase heater 3/8”-18NPSL
11. Plug low-pressure connection 1/8”-27NPTF
12. DTC valve plug connection 1/4”-18NPTF
13. Plug oil charge 1/4”-18NPTF
14. Plug high pressure connection 1/8”-27NPTF
1. Plug low pressure connection 1/8”-27NPTF
2. Plug low pressure connection 1/2”-14NPTF
3. Plug oil-pressure control L. P. 1/4”-18NPTF
4. Magnetic plug 1/8”-27NPTF
5. Nut high pressure connection 7/16”-20UNF
6. Plug high pressure connection 1/2”-14NPTF
7. Connection oil-pressure control H. P. 1/4”
SL Ø(Suction Line)
1 3/8”
1 5/8”
1 3/8”
1 3/8”
DL Ø(Discharge Line)
1 1/8”
1 1/8”
1 1/8”
1 1/8”
A(Mounting Length)
381 mm
381 mm
381 mm
381 mm
B(Mounting Width)
305 mm
305 mm
305 mm
305 mm
L(Length)
680mm
710 mm
653 mm
680 mm
W(Width)
370 mm
370 mm
370 mm
370 mm
H(Height)
443mm
443 mm
443 mm
443 mm
Model
3SCH-1000 / 3SCH-100E
3SSH-1500 / 3SSH-150E
3SC1-1000 / 3SC1-100E
3SS1-1500 / 3SS1-150E
3SCH-1000/3SCH-100E, 3SSH-1500/3SSH-150E,3SC1-1000/3SC1-100E, & 3SS1-1500/3SS1-150E
38
3S Series
Wiring Diagram
Electrical Diagram Coding:
A1: Motor protector module
A2: Oil differential Switch OPS2
D1: Operating recognition connection
E: Grounding Connection
E1: Crankcase heater
H1: Alarm indicator for motor protection
H2: Alarm indicator for oil differential pressure
K1: Contactor
K2: Thermostat
K3: Current sensing relay
L1, L2, L3: Voltage Connection
380-420V-3-50/60Hz-Y
220-240V-3-60Hz-Delta
440-480V-3-60Hz-Y
M: Compressor motor
N: Neutral connection
Q1: Mini-breaker
Q2: Mini-breaker
Rt: PTC Thermistors
S1: Control Switch
Y1: H/L pressure switches
Color code
VT: violet
OG: orange
GY: grey
BN: brown
BU: blue
PK: pink
Electrical Diagram with Motor Protector Code - F
Electrical Diagram for Motor Protector Code - W
K3
Control Circuit 220-240V 50/60Hz
Control Circuit 220-240V 50/60Hz
1(A 1)
2(A 1)
R tt
Rt
39
3S Series
Terminal Jumper Schematics
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
1(U) 2(V) 3(W)
7(Z) 8(X) 9(Y)
L1 L2 L3
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
Direct-on-line startY-
Direct-on-line start Direct-on-line startY
Star-delta-motorY-
Code E
Terminal Schematics (Code T)
1 2 3
LINE
Dual Voltage Motor
40
3S Series
Motor Current Data (A)
-45
2.0/2.4
2.6/3.1
�2.2/2.6
3.4/4.1�
4.2
5.4
�4.6
�7.2
-40
3.3/3.9
4.5/5.3
�3.4/4.0
�5.3/6.3
6.8
9.3
7.0�
11.0�
-35
4.8/5.7
6.7/7.9
5.5/6.5
8.1/9.6
10.0
13.8
11.4
16.8
-30
6.8/8.0
9.4/11.1
8.0/9.4
11.4/13.4
7.5/8.9
10.8/12.8
14.0
19.4
16.5
23.5
15.6
22.4
-25
8.6/10.2�
�12.4/14.7
9.2/10.8
12.6/14.8
10.5/12.4
14.7/17.3
9.9/11.8
14.0/16.5
�17.9
�25.7
18.9
25.9
21.7
30.3
20.7
28.9
-20
11.7/13.8
16.4/19.4
12.0/14.2
16.3/19.2
13.5/15.9
18.6/21.9
12.9/15.2
17.6/20.8
6.9/8.3
9.0/10.8
24.2
34.0
24.9
33.6
27.8
38.3
26.6
36.4
14.5
18.9
-15
14.8/17.5
20.6/24.3
15.4/18.2
20.6/24.3
16.9/19.9
23.1/27.2
16.3/19.2
21.9/25.8
8.9/10.7
11.6/13.9
30.6
42.5
31.9
42.5
34.8
47.6
33.6
45.2
18.7
24.4
-10
18.6/21.9
25.6/30.2
19.4/22.8
25.7/30.3
20.9/24.6
28.3/33.4
20.3/23.9
26.8/31.7
11.3/13.6
14.9/17.9
38.3
52.9
39.9
53.0
43.1
58.5
41.8
55.5
23.7
31.3
-5
23.0/27.2
31.4/37.1
23.9/28.2
31.5/37.2
25.4/30.0
34.4/40.6
24.9/29.4
32.5/38.4
14.3/17.2
18.7/22.4
47.6
64.9
49.4
65.1
52.5
71.1
51.5
67.2
30.0
39.3
0
28.3/33.4
38.2/45.1
30.7/36.2
41.3/48.8
17.9/21.5
23.4/28.1
58.5
78.9
63.4
85.4
37.6
49.1
5
34.4/40.6
46.0/54.3
36.6/43.2
49.2/58.1
22.0/26.4
29.8/35.8
71.1
95.0
75.6
101.7
46.2
62.6
7
37.1/43.8
49.5/58.4
39.2/46.3
52.7/62.2
23.9/28.7
31.3/37.6
76.7
102.2
81.0
108.9
50.2
65.7
12.5
45.5/53.7
60.0/70.8
29.8/35.8
38.9/46.7
94.0
123.9
62.6
81.7
10
41.5/49.0
55.0/64.9
27.0/32.4
35.3/42.4
85.8
113.6
56.7
74.1
3SCH-1000
3SSH-1500
3SC1-1000
3SS1-1500
3SCH-100E
3SSH-150E
3SC1-100E
3SS1-150E
3SC1-100E
3SS1-150E
3SCH-1000
3SSH-1500
3SC1-1000
3SS1-1500
3SCH-100E
3SSH-150E
3SC1-100E
3SS1-150E
3SC1-100E
3SS1-150E
R22 (400V-3-50Hz/380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
R404A/507 (400V-3-50Hz/380V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 107 12.5
Star Connection (Y)
R134a (400V-3-50Hz/380V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 107 12.5
Star Connection (Y)
R22 (230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 107 12.5
Delta Connection
R404A/507 (230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 107 12.5
Delta Connection
R134a (230V-3-60Hz) tc=40°C(CT)
Evaporating temperature °CModel
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 107 12.5
Delta Connection
41
4S/6S Series
Model Nomenclature & Bill of Materials
X X X X - X X X X - X X X - X X X
Oil TypeCode Description E Ester oil 0 Mineral oil
Bill of Materials
Displacement and Valve Plate
Compressor Motor TypeCode Phase Motor Type E Three Dual voltage A Three Part -winding start
Motor Rating Power Code HP 1500 15 2000 20 2500 25 3000 30 3200 32 3500 35 4000 40 5000 50
Compressor Motor ProtectionCode Type W Motor protection with thermistors and module in the terminal box
Compressor Family Series Code Description 4 4 cylinder 6 6 cylinder
Design Series Code Description
S Reed valve type T Two stage type
4S SeriesMounting PartsRotalock/Service valveCrankcase HeaterElectronic Oil Pressure Switch (OPS2)Motor Protection ModuleDischarge Temp Control Valve (DTC)
Bill of Materials (BOM)
Note: * To be ordered separately DTC Valve part number 510-0549-01 KIT-DTC VALVE (SENSING ON CYL. HEAD)(SUITABLE FOR 50Hz MOTOR) 510-0549-00 KIT-DTC VALVE (SENSING ON BODY)(SUITABLE FOR 60Hz MOTOR)
000√√√√√
*accessory
6S SeriesMounting PartsRotalalock/Service valveCrankcase HeaterElectronic Oil Pressure Switch (OPS2)Motor Protection ModuleDischarge Temp Control Valve (DTC)
010√√√√√√
000√√√√√
*accessory
Note: * To be ordered separately DTC Valve part number 510-0547-00 for 6SLW-2500(E) 510-0548-00 for 6STW-3200(E) 510-0577-00 for 6SUW-4000(E)
Model VariationCode Description
H HT/MTW MT/LT
Electrical CodeCode Voltage PH HzM 380-420PW 3 50D 440-480PW 3 60K 220-240∆ 3 60 380-420Y 3 60
42
4S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
4SLW-1500
4STW-2000
-40
11.4010.7010.009.208.407.606.805.905.104.305.505.806.006.206.406.506.506.606.506.4013.0012.1011.3010.409.508.707.806.906.105.205.906.206.506.807.007.207.407.607.807.90
-35
15.1014.4013.5012.6011.6010.609.708.607.606.506.106.506.907.207.507.707.807.908.008.00
17.5016.5015.4014.3013.2012.2011.2010.108.907.706.807.207.607.908.208.608.909.109.409.60
-30
19.7018.8017.8016.7015.6014.3013.0012.0010.609.306.707.207.708.108.508.809.109.309.509.60
23.1021.9020.6019.3017.9016.5015.1013.9012.5011.107.608.108.609.109.509.90
10.4010.8011.1011.50
-25
25.2024.1023.0021.8020.3018.9017.3015.7014.1012.807.107.808.409.009.50
10.0010.5010.8011.1011.4029.9028.4026.8025.3023.5021.8020.1018.4016.6015.208.509.109.70
10.3010.8011.4011.9012.4012.9013.40
Evaporating Temperature oCCondensingTemperature
oC -20
31.7030.5029.1027.7026.1024.3022.4020.6018.6016.707.508.309.109.90
10.6011.2011.8012.3012.7013.1037.8036.0034.2032.3030.4028.2026.2024.1021.9019.709.20
10.0010.7011.4012.1012.8013.5014.1014.7015.30
-15
39.3037.9036.3034.6032.7030.8028.7026.3024.1021.707.708.809.70
10.7011.5012.3013.0013.7014.3014.9047.1045.0042.8040.6038.3036.0033.6030.9028.3025.709.90
10.8011.7012.6013.4014.2015.0015.8016.5017.30
-10
48.1046.4044.6042.6040.5038.2035.8033.3030.7027.807.809.00
10.2011.3012.4013.3014.2015.1015.9016.6057.8055.3052.7050.1047.4044.7041.9039.1036.2032.9010.6011.6012.6013.6014.6015.6016.5017.5018.4019.30
-5
58.1056.2054.1051.8049.3046.7044.0041.1038.2035.107.809.20
10.6011.9013.1014.3015.4016.4017.4018.3069.9067.0064.0061.0057.9054.8051.6048.3044.9041.5011.1012.3013.5014.6015.8016.9018.0019.1020.2021.20
-45
8.307.807.106.505.805.204.503.80
4.905.005.205.305.405.405.305.20
9.308.607.907.206.605.905.204.60
5.105.305.505.705.806.006.106.20
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K3. Suction SH 20K4. Suction SH 20K + Fan5. Suction Gas Temperature 20°C + Fan + Liq. Inj.
43
4S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062
Model
4SAH-2000
4SHH-2500
4SJH-3000
-20
26.9025.5024.1022.7021.4020.0018.2016.7015.00
6.206.707.307.808.208.609.009.309.60
33.7031.9030.1028.4026.7025.0022.9021.2019.20
8.408.909.309.8010.3010.8011.3011.7012.10
39.8037.5035.3033.2031.0028.9026.0023.8021.20
9.7010.3010.9011.5012.1012.6013.1013.6014.00
-15
33.4031.8030.1028.5026.8025.2023.5021.9019.8017.70
6.307.007.708.308.909.409.90
10.3010.7011.10
41.6039.6037.6035.6033.7031.7029.8027.9025.4023.00
8.509.209.90
10.6011.2011.9012.5013.0013.6014.10
49.3046.8044.3041.9039.4037.0034.5032.1028.9025.80
10.0010.8011.7012.5013.2014.0014.7015.3015.9016.40
-10
41.1039.2037.2035.2033.2031.2029.2027.3025.3023.0020.5019.706.207.107.908.709.40
10.1010.7011.3011.8012.3012.8013.0050.9048.7046.4044.1041.8039.5037.2034.9032.7029.9027.0026.108.409.40
10.3011.2012.0012.8013.6014.3015.0015.6016.2016.4060.5057.7054.9052.1049.2046.4043.5040.6037.7034.2030.5029.3010.0011.1012.2013.3014.3015.2016.1017.0017.7018.4019.0019.20
-5
50.1047.7045.4043.1040.7038.3036.0033.6031.2028.9026.6025.705.907.008.008.909.80
10.7011.4012.2012.8013.5014.1014.3061.9059.3056.6054.0051.3048.6045.9043.1040.4037.6034.8033.708.109.30
10.4011.5012.6013.6014.6015.5016.4017.2017.9018.2073.7070.5067.2063.9060.6057.3053.9050.5047.0043.6040.1038.809.70
11.2012.5013.9015.1016.3017.4018.5019.5020.3021.1021.40
Evaporating Temperature oCCondensingTemperature
oC 0
60.4057.7054.9052.1049.3046.5043.7040.9038.1035.4032.6031.505.306.607.808.90
10.0011.1012.0012.9013.8014.6015.3015.6074.5071.5068.5065.4062.2059.0055.8052.5049.2045.9042.6041.207.508.90
10.3011.7013.0014.2015.4016.5017.6018.6019.5019.8088.8085.2081.5077.7073.8069.8065.9061.8057.7053.6049.5047.809.20
10.9012.6014.2015.7017.2018.6019.9021.1022.2023.2023.60
5
65.8062.6059.3056.0052.7049.4046.1042.8039.5038.20
7.408.80
10.1011.3012.4013.5014.6015.5016.5016.80
82.1078.5074.8071.0067.2063.3059.4055.5051.4049.80
9.9011.6013.1014.6016.0017.4018.7019.9021.0021.40
97.8093.4088.9084.3079.6074.9070.0065.2060.2058.20
12.3014.2016.0017.8019.5021.0022.5023.9025.1025.60
7
70.6067.2063.7060.2056.6053.1049.6046.1042.6041.20
7.208.60
10.0011.3012.5013.7014.8015.9016.9017.30
88.1084.2080.3076.3072.2068.1063.9059.6055.4053.60
9.7011.4013.1014.7016.2017.7019.1020.3021.5022.00
105.00100.5095.5090.7085.7080.6075.5070.2064.9062.80
12.0014.1016.1018.0019.8021.4023.0024.5025.8026.30
12.5
81.1077.0072.8068.6064.5060.3056.1051.9050.30
8.009.60
11.2012.6014.1015.4016.7017.9018.40
102.0097.1092.4087.5082.6077.5072.4067.2065.20
10.8012.8014.7016.6018.3020.0021.5023.0023.50
121.50116.00110.00104.0098.0091.9085.7079.3076.80
13.6015.9018.2020.3022.3024.2026.0027.6028.30
10
74.5070.7066.8063.0059.1055.2051.4047.5046.00
8.309.80
11.3012.6013.9015.2016.4017.5017.90
93.5089.2084.8080.3075.7071.1066.4061.6059.70
11.1013.0014.8016.5018.1019.6021.0022.3022.90
111.50106.00101.0095.4089.8084.1078.4072.5070.20
13.9016.0018.1020.1021.9023.7025.3026.8027.40
-25
21.4020.2019.1017.9016.8015.2013.9012.7011.20
5.906.406.807.207.507.808.108.308.50
27.0025.4023.8022.2020.8018.8017.2015.8014.00
8.008.308.709.009.309.6010.0010.3010.60
31.7029.7027.7025.8023.9021.1019.2017.3014.90
9.209.6010.0010.4010.8011.1011.5011.8012.10
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 10K + Fan
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan4. Suction SH 20K5. Liquid subcooling 0K
44
4S Series
50 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
4SLW-150E
4STW-200E
-40
15.1013.9012.8011.7010.608.807.706.705.704.706.206.606.807.007.107.107.106.906.706.4018.1016.8015.6014.3013.0010.909.608.307.105.907.807.908.108.208.308.408.408.308.207.90
-35
19.7018.4017.0015.7014.5013.2011.909.708.407.107.107.507.908.208.408.508.608.608.508.40
23.7022.2020.7019.2017.6016.0014.5011.8010.208.608.809.109.409.709.90
10.1010.2010.2010.2010.10
-30
25.4023.8022.2020.6019.0017.5015.9014.4012.809.907.808.408.909.309.70
10.0010.2010.4010.4010.4030.6028.8026.9025.0023.1021.1019.2017.2015.3011.809.70
10.2010.7011.1011.5011.8012.0012.2012.3012.30
-25
32.2030.2028.3026.4024.5022.5020.6018.7016.7014.708.609.309.90
10.5011.0011.4011.8012.1012.3012.4038.8036.5034.2031.9029.5027.2024.7022.3019.9017.4010.7011.3011.9012.5013.0013.5013.9014.2014.4014.60
Evaporating Temperature oCCondensingTemperature
oC -20
37.9035.6033.2030.8028.5026.1023.7021.2018.80
10.1010.9011.6012.2012.8013.3013.8014.2014.50
45.6042.9040.0037.2034.2031.3028.3025.3022.30
12.3013.1013.8014.5015.2015.8016.2016.7017.00
-15
44.1041.2038.3035.4032.5029.5026.5023.50
11.7012.6013.4014.1014.8015.5016.0016.50
52.8049.4046.0042.5038.9035.3031.7028.00
14.2015.1016.0016.9017.6018.3018.9019.40
-10
50.5047.0043.5040.0036.4032.8027.60
13.5014.5015.4016.3017.1017.8018.50
60.2056.1052.0047.7043.4039.1032.90
16.4017.5018.5019.5020.4021.1021.80
-5
57.0052.8048.6044.3040.0034.70
15.4016.5017.6018.6019.5020.40
67.7062.8057.8052.7047.6041.40
18.9020.1021.3022.4023.4024.30
-45
11.4010.309.207.706.705.804.904.00
5.405.605.805.805.805.705.505.30
13.5012.4011.409.708.607.506.405.40
6.706.806.806.906.806.806.706.50
R404A /507R404A /507
45
4S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
202530354045505520253035404550552025303540455055202530354045505520253035404550552025303540455055
Model
4SAH-200E
4SHH-250E
4SJH-300E
-30
16.7015.3013.9012.6011.309.908.707.506.907.107.307.507.507.607.507.4020.8019.3017.7016.1014.6013.0011.5010.008.809.209.509.709.809.909.909.9026.0023.9021.8019.8017.7015.7013.7011.7010.2010.6010.9011.1011.2011.2011.1010.90
-25
21.5019.9018.2016.6015.0013.4011.8010.307.708.008.308.608.808.908.908.90
26.9025.0023.1021.1019.2017.3015.4013.509.80
10.3010.8011.1011.4011.6011.8011.8033.6031.1028.6026.1023.6021.2018.8016.4011.4012.0012.5012.9013.2013.4013.5013.50
-20
27.3025.3023.3021.3019.3017.4015.4013.508.308.809.309.609.90
10.2010.4010.5034.1031.8029.5027.1024.7022.3019.9017.5010.7011.4012.0012.5012.9013.3013.6013.8042.5039.4036.4033.4030.5027.5024.6021.7012.5013.3014.0014.6015.1015.5015.8016.10
-15
34.1031.7029.2026.8024.4022.0019.7017.308.909.50
10.1010.7011.1011.5011.8012.0042.6039.9037.0034.1031.2028.2025.2022.2011.4012.3013.0013.7014.4014.9015.4015.7052.8049.1045.5041.8038.2034.7031.1027.6013.4014.4015.3016.1016.9017.5018.1018.50
Evaporating Temperature oCCondensingTemperature
oC -10
41.9039.1036.2033.3030.4027.5024.6021.709.30
10.1010.9011.5012.1012.7013.1013.5052.6049.2045.8042.3038.7035.1031.4027.7012.0013.0014.0014.9015.7016.4017.1017.6064.7060.2055.8051.5047.1042.8038.5034.3014.1015.3016.5017.5018.5019.4020.1020.70
-5
50.9047.5044.1040.7037.2033.8030.3026.909.50
10.5011.4012.3013.1013.8014.4015.0064.0060.0055.9051.7047.4043.0038.6034.1012.3013.5014.7015.9016.9017.9018.7019.5078.1072.8067.6062.3057.2052.0046.9041.8014.6016.0017.4018.7019.9021.0022.0022.90
0
61.2057.2053.2049.1045.1041.0036.9032.909.50
10.7011.8012.8013.8014.7015.6016.3077.0072.3067.4062.4057.3052.1046.9041.5012.3013.8015.3016.7017.9019.1020.2021.1093.3087.0080.8074.6068.5062.4056.3050.3014.8016.5018.1019.7021.1022.4023.7024.80
7
77.8072.8067.8062.8057.8052.8047.8042.709.00
10.5012.0013.3014.6015.8016.9018.0098.2092.2086.1079.9073.5067.0060.4053.7011.9013.8015.7017.4019.0020.6022.0023.30
117.50110.00102.0094.4086.7079.1071.5064.0014.7016.7018.7020.6022.3024.0025.6027.10
5
72.8068.1063.4058.7054.0049.2044.5039.709.20
10.6012.0013.2014.4015.5016.6017.5091.8086.2080.4074.6068.6062.5056.3050.0012.1013.9015.6017.2018.8020.2021.5022.70
110.50103.0095.6088.4081.2074.0066.9059.9014.8016.7018.6020.3022.0023.6025.1026.50
-35
12.7011.5010.309.20
6.006.206.306.30
15.9014.5013.2011.90
7.808.008.108.20
19.6017.8016.1014.30
8.909.109.209.20
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 20°C + Fan3. Liquid subcooling 0K
R404A /507R404A /507
46
4S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065
Model
4SAH-200E
4SHH-250E
4SJH-300E
-20
24.5023.3022.1020.8019.5018.1016.1014.6013.2011.70
5.405.906.406.907.307.607.908.208.408.50
29.1027.9026.5025.1023.6022.1019.6017.9016.2014.50
7.307.808.308.709.109.509.8010.1010.4010.60
34.7033.4031.9030.2028.4026.5023.4021.1018.9016.60
8.609.4010.1010.7011.2011.50
-15
30.8029.4027.9026.3024.7023.1021.4019.8017.3015.6013.80
5.606.306.907.508.008.508.909.209.509.8010.00
36.9035.5033.9032.1030.3028.4026.4024.4021.4019.3017.20
7.708.409.009.6010.2010.7011.1011.5011.9012.3012.60
44.2042.5040.7038.7036.6034.3031.9029.4025.6022.8020.00
9.0010.1011.0011.8012.5013.1013.6014.00
-10
38.4036.7034.9033.0031.1029.1027.1025.0022.9020.8018.1015.905.606.507.208.008.609.209.80
10.3010.7011.1011.4011.6046.4044.6042.6040.5038.3036.0033.5031.1028.5026.0022.6020.007.908.809.60
10.4011.1011.8012.4012.9013.4013.9014.4014.8055.5053.5051.2048.8046.2043.4040.5037.4034.3031.1026.7023.309.10
10.5011.7012.8013.7014.6015.3015.9016.4016.70
-5
47.3045.2043.1040.9038.5036.2033.7031.2028.7026.2023.6021.005.506.507.408.309.209.90
10.7011.3011.8012.3012.8013.1057.5055.4053.0050.4047.7044.9041.9038.9035.8032.7029.5026.307.909.00
10.0011.0011.9012.7013.5014.2014.9015.6016.2016.8068.8066.3063.6060.6057.4054.0050.5046.8043.0039.1035.1031.008.90
10.6012.1013.4014.7015.8016.8017.6018.4019.0019.5019.80
Evaporating Temperature oCCondensingTemperature
oC 0
57.7055.2052.7050.1047.3044.5041.5038.6035.5032.5029.4026.305.106.307.508.509.50
10.5011.4012.2012.9013.5014.1014.6070.7068.0065.1062.1058.8055.4051.8048.1044.4040.5036.7032.807.508.90
10.2011.4012.5013.5014.5015.4016.3017.2018.0018.7084.4081.3077.9074.3070.4066.3062.0057.6053.0048.3043.5038.608.30
10.3012.1013.8015.3016.7018.0019.1020.1021.0021.7022.30
5
66.9063.8060.7057.5054.1050.6047.1043.5039.9036.2032.50
5.907.208.509.70
10.9012.0012.9013.8014.7015.4016.10
82.8079.3075.6071.7067.6063.3058.9054.4049.8045.1040.40
8.5010.0011.5012.8014.1015.3016.5017.6018.6019.6020.60
98.6094.4090.0085.3080.4075.3070.0064.5058.8053.0047.20
9.6011.8013.8015.7017.4018.9020.4021.6022.8023.8024.70
7
68.8065.4061.9058.4054.7050.9047.1043.2039.2035.30
7.108.409.70
11.0012.1013.2014.2015.1015.9016.60
85.6081.6077.4073.0068.4063.7058.8053.9048.8043.70
9.9011.4012.9014.3015.6016.9018.0019.2020.2021.30
101.5097.0091.9086.6081.1075.4069.5063.4057.2050.90
11.6013.7015.7017.5019.2020.8022.2023.5024.6025.60
12.5
79.8075.7071.4067.0062.5058.0053.3048.6043.80
8.009.60
11.1012.5013.8015.0016.1017.2018.10
99.9094.8089.5084.0078.3072.5066.5060.4054.20
11.1012.8014.5016.1017.7019.1020.5021.9023.10
118.00112.00105.5098.8091.9084.7077.4069.9062.30
13.1015.5017.7019.8021.7023.4025.0026.5027.90
15
87.1082.7078.0073.3068.4063.5058.4053.3048.20
7.709.40
11.0012.5014.0015.3016.5017.7018.70
109.00103.5097.9092.0085.8079.4072.9066.3059.60
10.7012.7014.5016.3017.9019.5021.0022.5023.90
129.00122.00115.00107.50100.0092.4084.4076.3068.00
12.6015.2017.6019.9021.9023.9025.6027.3028.80
10
76.7073.0069.2065.2061.2057.0052.8048.5044.1039.70
6.708.309.70
11.1012.4013.5014.7015.7016.6017.50
95.6091.2086.6081.7076.6071.4066.0060.5054.9049.20
9.5011.3012.9014.5015.9017.3018.7019.9021.1022.30
113.50108.00102.5096.6090.4084.1077.5070.8063.9056.90
11.1013.4015.6017.7019.6021.3022.9024.4025.7026.90
-25
19.3018.3017.2016.2015.1013.3012.1010.909.70
5.105.505.906.206.506.707.007.107.20
22.6021.6020.5019.3018.1015.9014.5013.1011.80
6.707.107.507.808.008.308.508.708.80
26.9025.8024.5023.0021.5018.7016.9015.0013.10
7.908.509.009.309.60
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 20K + Fan
47
4S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
4SLW-1500
4STW-2000
-40
13.4012.6011.8010.9010.009.008.007.006.005.006.607.007.307.507.707.807.907.907.807.7015.3014.3013.3012.3011.3010.309.208.207.206.107.107.507.808.108.408.708.909.109.309.50
-35
17.8017.0016.0014.9013.7012.5011.4010.208.907.607.307.808.308.608.909.209.409.509.609.60
20.7019.5018.2016.9015.6014.4013.2011.9010.509.108.208.609.109.509.90
10.3010.7011.0011.3011.60
-30
23.2022.2021.0019.7018.4016.9015.4014.1012.6011.008.008.609.209.80
10.2010.6011.0011.2011.4011.6027.3025.8024.3022.7021.1019.5017.8016.4014.8013.009.209.80
10.4010.9011.4012.0012.4012.9013.4013.80
-25
29.7028.5027.1025.7024.0022.2020.4018.6016.6015.108.609.40
10.2010.9011.5012.1012.5013.0013.3013.6035.3033.5031.6029.8027.7025.8023.7021.6019.6017.9010.2010.9011.6012.3013.0013.6014.3014.9015.5016.00
Evaporating Temperature oCCondensingTemperature
oC -20
37.4035.9034.4032.6030.8028.6026.5024.3022.0019.609.00
10.0011.0011.9012.7013.4014.1014.7015.3015.7044.7042.5040.3038.1035.9033.3030.9028.4025.9023.3011.1012.0012.9013.7014.5015.4016.1016.9017.6018.40
-15
46.3044.7042.8040.8038.6036.3033.9031.1028.4025.609.30
10.5011.7012.8013.8014.8015.6016.4017.2017.8055.6053.1050.5047.9045.2042.4039.6036.4033.4030.4012.0013.0014.0015.1016.1017.0018.0018.9019.9020.70
-10
56.7054.7052.6050.3047.7045.1042.3039.3036.3032.809.40
10.9012.3013.6014.8016.0017.1018.1019.1019.9068.2065.2062.2059.1056.0052.8049.5046.1042.7038.8012.7013.9015.2016.4017.5018.7019.8020.9022.0023.10
-5
68.6066.3063.8061.1058.2055.2051.9048.5045.0041.409.30
11.0012.7014.2015.7017.1018.4019.7020.9022.0082.5079.0075.6072.0068.4064.6060.8057.0053.0048.9013.3014.7016.1017.5018.9020.3021.6022.9024.2025.50
-45
9.809.208.407.706.906.105.304.50
5.806.106.206.406.406.406.406.30
11.0010.209.308.507.707.006.205.40
6.106.406.606.807.007.207.307.40
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K3. Suction SH 20K4. Suction SH 20K + Fan5. Suction Gas Temperature 20°C + Fan + Liq. Inj.
48
4S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062
Model
4SAH-2000
4SHH-2500
4SJH-3000
-20
31.7030.1028.5026.8025.2023.6021.4019.7017.70
7.408.108.709.309.9010.4010.8011.2011.60
39.7037.6035.5033.5031.5029.6027.0025.0022.60
10.1010.7011.2011.8012.4013.0013.5014.0014.50
46.9044.3041.7039.1036.6034.1030.7028.1025.00
11.7012.4013.1013.8014.5015.1015.7016.3016.80
-15
39.5037.5035.6033.6031.6029.7027.7025.8023.3020.90
7.508.409.209.90
10.7011.3011.9012.4012.9013.40
49.1046.7044.4042.1039.7037.4035.2032.9030.0027.20
10.3011.1011.9012.7013.5014.2015.0015.6016.3016.90
58.2055.3052.3049.4046.5043.6040.7037.9034.1030.40
12.0013.0014.0015.0015.9016.8017.6018.4019.1019.70
-10
48.5046.2043.9041.5039.2036.9034.5032.2029.9027.1024.2023.207.408.509.50
10.4011.3012.1012.9013.5014.2014.8015.4015.6060.1057.4054.8052.1049.4046.6043.9041.2038.5035.3031.9030.8010.2011.3012.3013.4014.4015.4016.3017.2018.0018.8019.4019.7071.4068.1064.8061.4058.1054.7051.3047.9044.5040.4036.0034.6012.0013.4014.7015.9017.1018.3019.3020.3021.2022.1022.8023.10
-5
59.1056.3053.6050.8048.0045.2042.4039.6036.9034.1031.4030.307.108.309.60
10.7011.8012.8013.7014.6015.4016.2016.9017.2073.0069.9066.8063.7060.5057.3054.1050.9047.6044.4041.1039.809.70
11.1012.5013.8015.1016.3017.5018.6019.6020.6021.4021.8086.9083.2079.3075.5071.5067.6063.6059.5055.5051.4047.4045.7011.7013.4015.0016.6018.1019.6020.9022.2023.3024.4025.4025.70
Evaporating Temperature oCCondensingTemperature
oC 0
71.3068.1064.8061.5058.2054.9051.6048.3045.0041.7038.5037.206.407.909.40
10.8012.1013.3014.4015.5016.5017.5018.4018.7087.9084.4080.8077.1073.4069.7065.8062.0058.1054.2050.2048.609.00
10.7012.4014.0015.6017.1018.5019.8021.1022.3023.4023.80
105.00100.5096.1091.6087.1082.4077.7072.9068.1063.3058.4056.4011.0013.1015.1017.0018.8020.6022.2023.8025.3026.6027.8028.30
5
77.7073.8070.0066.1062.2058.3054.4050.5046.6045.10
8.9010.5012.1013.5014.9016.2017.5018.6019.8020.20
96.9092.6088.3083.8079.3074.7070.1065.4060.7058.80
11.9013.9015.7017.5019.2020.9022.4023.8025.2025.70
115.50110.00105.0099.5094.0088.3082.7076.9071.1068.70
14.7017.0019.2021.3023.3025.2027.0028.6030.1030.70
7
83.3079.3075.1071.0066.8062.7058.5054.4050.3048.60
8.6010.4012.0013.6015.0016.4017.8019.1020.2020.70
104.0099.4094.8090.0085.2080.4075.4070.4065.3063.30
11.6013.7015.7017.6019.5021.2022.9024.4025.9026.40
124.00118.50112.50107.00101.0095.1089.0082.9076.6074.10
14.4016.9019.3021.5023.7025.7027.6029.4031.0031.60
12.5
95.7090.8085.9081.0076.1071.1066.2061.3059.30
9.5011.5013.4015.2016.9018.5020.0021.5022.10
120.00114.50109.00103.0097.4091.5085.5079.4076.90
13.0015.4017.7019.9021.9023.9025.8027.6028.20
143.50136.50130.00123.00115.50108.50101.0093.6090.60
16.3019.1021.8024.3026.8029.1031.2033.2033.90
10
87.9083.4078.9074.3069.7065.2060.6056.1054.30
10.0011.8013.5015.2016.7018.2019.6021.0021.50
110.50105.00100.0094.7089.4083.9078.3072.7070.40
13.4015.6017.7019.7021.7023.5025.2026.8027.40
131.50125.50119.00112.50106.0099.3092.5085.6082.80
16.6019.2021.7024.1026.3028.4030.4032.2032.90
-25
25.2023.9022.5021.1019.8017.9016.4015.0013.20
7.107.708.208.609.009.409.7010.0010.30
31.8029.9028.1026.3024.5022.1020.3018.6016.50
9.6010.0010.4010.8011.2011.6012.0012.3012.70
37.4035.0032.7030.4028.2024.9022.6020.4017.60
11.1011.5012.0012.5012.9013.4013.8014.1014.50
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 10K + Fan
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan4. Suction SH 20K5. Liquid subcooling 0K
49
4S Series
60 Hz
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
10152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
4SLW-150E
4STW-200E
-40
17.8016.4015.1013.8012.5010.409.107.906.705.507.507.908.208.408.508.508.508.308.107.7021.3019.8018.4016.9015.4012.9011.309.808.307.009.309.509.709.9010.0010.1010.1010.009.809.50
-35
23.3021.7020.1018.6017.1015.6014.1011.509.908.408.509.009.509.80
10.1010.3010.4010.4010.3010.1028.0026.2024.4022.6020.7018.9017.1013.9012.0010.1010.6010.9011.3011.6011.9012.1012.2012.3012.2012.10
-30
29.9028.0026.2024.3022.4020.6018.8017.0015.1011.709.40
10.1010.7011.2011.7012.0012.3012.4012.5012.5036.1033.9031.7029.5027.2024.9022.6020.3018.0013.9011.7012.3012.8013.3013.7014.1014.4014.6014.7014.70
-25
38.0035.7033.4031.1028.9026.6024.3022.0019.7017.4010.3011.2011.9012.6013.2013.7014.1014.5014.8014.9045.7043.1040.4037.7034.9032.0029.2026.3023.4020.5012.8013.6014.3015.0015.6016.2016.6017.0017.3017.50
Evaporating Temperature oCCondensingTemperature
oC -20
44.7042.0039.2036.4033.6030.8027.9025.0022.10
12.1013.0013.9014.7015.4016.0016.5017.0017.40
53.8050.6047.2043.8040.4036.9033.4029.9026.30
14.8015.7016.6017.4018.2018.9019.5020.0020.30
-15
52.0048.6045.2041.8038.3034.8031.3027.70
14.0015.1016.1017.0017.8018.5019.2019.80
62.3058.3054.3050.1045.9041.7037.4033.10
17.0018.2019.2020.2021.1021.9022.7023.20
-10
59.5055.5051.3047.2042.9038.7032.60
16.2017.3018.5019.5020.4021.3022.20
71.1066.2061.3056.3051.2046.1038.90
19.7021.0022.2023.4024.4025.4026.20
-5
67.3062.3057.4052.3047.2041.00
18.5019.8021.1022.3023.4024.50
79.9074.1068.2062.2056.2048.80
22.6024.1025.6026.9028.1029.20
-45
13.4012.1010.909.107.906.805.704.70
6.406.706.907.007.006.906.706.40
15.9014.7013.4011.4010.108.807.606.40
8.008.108.208.208.208.208.007.80
R404A /507R404A /507
50
4S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
202530354045505520253035404550552025303540455055202530354045505520253035404550552025303540455055
Model
4SAH-200E
4SHH-250E
4SJH-300E
-30
19.7018.0016.4014.8013.3011.8010.308.808.308.608.808.909.009.109.008.9024.6022.7020.8019.0017.2015.4013.6011.8010.6011.0011.4011.6011.8011.9011.9011.9030.7028.2025.7023.3020.9018.5016.1013.8012.3012.7013.0013.3013.4013.4013.3013.10
-25
25.4023.4021.5019.6017.6015.8013.9012.109.209.60
10.0010.3010.5010.7010.8010.7031.7029.5027.2024.9022.7020.4018.2015.9011.8012.4012.9013.3013.7014.0014.1014.2039.6036.7033.7030.8027.9025.0022.2019.4013.7014.4015.0015.4015.8016.1016.2016.20
-20
32.2029.8027.5025.1022.8020.5018.2016.0010.0010.6011.2011.6012.0012.3012.5012.6040.3037.5034.8032.0029.2026.3023.5020.6012.9013.6014.3015.0015.5016.0016.3016.5050.1046.5043.0039.4035.9032.4029.0025.6015.0015.9016.7017.5018.1018.6019.0019.30
-15
40.2037.4034.5031.7028.8026.0023.2020.4010.7011.5012.2012.8013.3013.8014.1014.4050.3047.0043.7040.3036.8033.3029.8026.2013.7014.7015.6016.5017.2017.9018.4018.9062.3058.0053.7049.4045.1040.9036.7032.6016.0017.2018.3019.3020.2021.0021.6022.10
Evaporating Temperature oCCondensingTemperature
oC -10
49.5046.1042.7039.3035.8032.4029.0025.7011.2012.1013.0013.8014.6015.2015.8016.2062.0058.1054.0049.9045.7041.4037.1032.7014.3015.6016.8017.9018.9019.7020.5021.1076.3071.1065.9060.7055.6050.5045.5040.5016.9018.4019.7021.0022.2023.2024.1024.90
-5
60.1056.1052.0048.0043.9039.9035.8031.8011.4012.6013.7014.7015.7016.5017.3018.0075.5070.8065.9060.9055.9050.8045.5040.3014.7016.2017.7019.0020.3021.4022.4023.3092.2085.9079.7073.6067.5061.4055.4049.4017.5019.2020.9022.4023.9025.2026.4027.40
0
72.2067.5062.7058.0053.2048.4043.6038.8011.4012.8014.2015.4016.6017.7018.7019.6090.9085.3079.5073.6067.6061.5055.3049.0014.8016.6018.4020.0021.5022.9024.2025.40
110.00102.5095.4088.1080.8073.6066.5059.4017.8019.8021.7023.6025.3026.9028.4029.70
7
91.8085.9080.1074.2068.2062.3056.4050.4010.8012.6014.4016.0017.5018.9020.3021.50
116.00109.00101.5094.2086.7079.1071.3063.4014.3016.6018.8020.9022.8024.7026.4028.00
138.50129.50120.50111.50102.5093.3084.4075.5017.6020.0022.4024.7026.8028.8030.7032.50
5
85.8080.3074.8069.3063.7058.1052.5046.9011.1012.8014.4015.9017.3018.6019.9021.00
108.50101.5094.9088.0080.9073.7066.4059.0014.5016.7018.7020.7022.5024.2025.8027.30
130.00121.50113.00104.5095.8087.4079.0070.7017.7020.0022.3024.4026.4028.4030.1031.80
-35
14.9013.6012.2010.90
7.207.407.507.60
18.8017.2015.6014.00
9.309.609.809.90
23.1021.0019.0016.90
10.8010.9011.0011.00
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 20°C + Fan3. Liquid subcooling 0K
R404A /507R404A /507
51
4S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065
Model
4SAH-200E
4SHH-250E
4SJH-300E
-20
28.9027.5026.0024.5022.9021.3019.0017.2015.5013.80
6.507.107.708.208.709.109.509.8010.1010.30
34.3032.9031.3029.6027.9026.0023.1021.0019.1017.10
8.809.4010.0010.5011.0011.4011.8012.1012.4012.70
40.5038.8036.9034.8032.5030.1027.6025.0022.3019.50
10.3011.3012.1012.8013.4013.8014.1014.3014.4014.30
-15
36.4034.7032.9031.1029.2027.3025.3023.3020.4018.4016.30
6.707.508.309.009.60
10.2010.7011.1011.5011.8012.00
43.6041.8039.9037.9035.8033.5031.2028.8025.3022.8020.30
9.3010.1010.9011.6012.2012.8013.3013.8014.3014.7015.10
51.9049.8047.6045.1042.4039.5036.5033.4030.2026.9023.60
10.8012.1013.2014.2015.1015.8016.3016.8017.1017.3017.30
-10
45.3043.3041.2038.9036.7034.3031.9029.5027.0024.6021.3018.806.807.808.709.60
10.4011.1011.8012.4012.9013.3013.6013.9054.7052.6050.3047.8045.2042.4039.6036.6033.7030.7026.6023.509.50
10.6011.6012.5013.3014.1014.8015.5016.1016.7017.3017.8065.3062.9060.2057.2054.0050.6047.0043.3039.5035.5031.5027.5010.9012.6014.0015.3016.5017.5018.3019.1019.7020.1020.4020.50
-5
55.8053.4050.9048.2045.5042.7039.8036.9033.9030.9027.9024.806.607.808.90
10.0011.0011.9012.8013.5014.2014.8015.3015.7067.9065.3062.5059.5056.3053.0049.5045.9042.3038.5034.8031.009.50
10.8012.0013.2014.3015.3016.2017.1017.9018.7019.4020.1081.2078.2074.9071.3067.5063.4059.2054.7050.2045.5040.7035.8010.7012.7014.5016.1017.6018.9020.1021.1022.0022.7023.3023.80
Evaporating Temperature oCCondensingTemperature
oC 0
68.0065.2062.2059.1055.8052.5049.0045.5041.9038.3034.7031.006.107.608.90
10.3011.5012.6013.6014.6015.5016.3016.9017.5083.4080.3076.9073.2069.4065.3061.1056.8052.4047.8043.3038.609.00
10.7012.2013.6015.0016.2017.4018.5019.6020.6021.5022.4099.5095.9091.9087.6083.1078.2073.2068.0062.5057.0051.3045.5010.0012.3014.5016.5018.4020.0021.6022.9024.1025.2026.1026.80
5
78.9075.3071.6067.8063.8059.8055.6051.4047.1042.7038.30
7.008.70
10.3011.7013.1014.3015.5016.6017.6018.5019.30
97.7093.6089.2084.6079.7074.7069.5064.2058.7053.2047.60
10.2012.0013.8015.4016.9018.4019.8021.1022.3023.5024.70
116.00111.50106.50101.0095.2089.3083.1076.8070.2063.5056.70
11.6014.2016.6018.8020.8022.7024.4026.0027.4028.6029.70
7
81.2077.2073.1068.9064.5060.1055.5050.9046.3041.60
8.5010.2011.7013.2014.6015.8017.0018.1019.1020.00
101.0096.3091.3086.1080.7075.2069.4063.6057.6051.60
11.9013.7015.5017.1018.7020.2021.6023.0024.3025.50
120.00114.50109.00102.5096.4089.8083.0076.1069.0061.70
13.9016.4018.8021.0023.1024.9026.6028.2029.5030.70
12.5
94.2089.3084.3079.1073.8068.4062.9057.3051.70
9.6011.5013.3015.0016.5018.0019.3020.6021.70
118.00112.00105.5099.1092.4085.5078.5071.3064.00
13.3015.4017.4019.4021.2022.9024.6026.2027.80
139.50132.50125.50118.00110.00102.0093.8085.5076.90
15.7018.6021.2023.7026.0028.1030.1031.8033.40
15
103.0097.5092.1086.5080.8074.9069.0062.9056.80
9.3011.3013.2015.0016.7018.3019.8021.2022.40
129.00122.50115.50108.50101.0093.7086.0078.2070.30
12.9015.2017.4019.5021.5023.4025.3027.0028.70
151.50144.50136.50128.50120.00111.50103.0093.8084.60
15.2018.2021.1023.8026.3028.6030.8032.7034.50
10
90.5086.1081.6077.0072.2067.3062.3057.2052.1046.90
8.109.90
11.7013.3014.8016.2017.6018.8019.9020.90
113.00107.50102.0096.4090.4084.2077.9071.4064.8058.10
11.5013.5015.5017.3019.1020.8022.4023.9025.4026.80
133.50127.50121.50114.50107.50100.5093.1085.5077.7069.70
13.3016.1018.8021.2023.5025.6027.5029.2030.8032.20
-25
22.7021.5020.3019.1017.8015.7014.2012.8011.50
6.106.607.007.407.808.108.308.508.70
26.7025.5024.2022.8021.3018.7017.1015.5013.90
8.108.609.009.309.609.9010.2010.4010.60
31.1029.6028.0026.1024.2022.1019.9017.7015.40
9.5010.2010.8011.2011.5011.7011.8011.8011.60
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 20K + Fan
52
6S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550551015202530354045505510152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
6SLW-2500
6STW-3200
6SUW-4000
-40
16.4015.3014.2013.0011.8010.609.408.207.005.907.908.308.709.109.409.709.9010.1010.1010.1020.4018.8017.2015.7014.1012.6011.209.808.407.2010.3010.6010.7010.8011.0011.1011.2011.3011.5011.8024.2022.9021.5019.9018.3016.6014.8013.0011.209.4012.0012.4012.8013.2013.6013.9014.2014.4014.6014.60
-35
22.3021.1019.6018.1016.6015.1013.7012.2010.609.108.909.50
10.1010.6011.0011.5011.8012.1012.3012.4027.0025.2023.3021.3019.5017.8016.1014.4012.7011.1011.5011.9012.2012.5012.8013.1013.4013.7014.1014.5032.4030.9029.1027.2025.2023.0021.2019.0016.7014.4013.6014.2014.8015.4016.0016.5016.9017.3017.6017.80
-30
29.4027.8026.2024.4022.5020.6018.7017.1015.2013.409.90
10.7011.4012.1012.7013.3013.8014.3014.6014.9035.1032.9030.7028.4026.1023.9021.8020.0018.0016.0012.5013.2013.7014.3014.8015.2015.7016.2016.7017.3042.3040.6038.6036.3033.8031.2028.5026.2023.4020.5015.0015.9016.7017.5018.3019.0019.7020.2020.7021.10
-25
37.6035.8033.8031.8029.5027.3025.0022.7020.5018.6010.9011.8012.7013.6014.4015.2015.9016.5017.0017.4044.6042.1039.5036.9034.2031.6029.0026.4024.1022.0013.6014.5015.3016.0016.7017.4018.1018.8019.5020.2054.3052.2049.9047.3044.2041.1037.8034.4030.9028.0016.3017.4018.5019.5020.5021.5022.4023.2023.9024.60
Evaporating Temperature oCCondensingTemperature
oC -20
47.0044.9042.6040.3037.9035.1032.5029.8027.1024.4011.7012.8013.9015.0016.0017.0017.9018.7019.4020.0055.8052.8049.9046.9043.9040.7037.6034.6031.6028.8014.7015.8016.9017.8018.8019.7020.5021.4022.3023.2068.5066.0063.2060.1056.8052.9049.0045.0040.7036.4017.2018.7020.0021.4022.7023.9025.1026.2027.2028.10
-15
57.5055.1052.6050.0047.2044.4041.4038.1035.0031.9012.3013.7015.0016.3017.5018.7019.8020.7021.7022.5068.8065.4061.9058.5055.1051.6048.2044.3040.8037.4015.8017.2018.5019.7020.9022.0023.1024.2025.3026.4085.0082.0078.8075.2071.3067.1062.7057.5052.5047.3017.9019.7021.4023.1024.7026.3027.8029.2030.5031.70
-10
69.3066.6063.8060.8057.7054.5051.2047.9044.4040.6012.7014.2015.8017.3018.7020.1021.4022.7023.8024.8083.6079.8075.8071.9067.9064.0060.0056.0052.1047.7016.9018.6020.1021.6023.0024.4025.8027.1028.4029.80
104.00100.5096.7092.5088.0083.1077.9072.5066.8060.3018.3020.4022.5024.6026.6028.5030.3032.1033.7035.30
-5
82.4079.4076.2072.9069.5065.9062.2058.5054.6050.7012.6014.5016.3018.0019.7021.3022.9024.4025.7027.00
100.5096.2091.7087.2082.7078.1073.6069.0064.5060.0018.1020.0021.8023.6025.3026.9028.5030.1031.7033.30
126.00122.00117.50112.50107.00101.5095.5089.3082.7075.9018.2020.8023.3025.8028.2030.5032.7034.9036.9038.80
-45
11.4010.609.708.807.907.006.105.30
7.007.207.507.707.908.008.108.20
15.0013.7012.3011.009.708.407.206.10
9.209.209.209.109.109.009.009.00
17.7016.5015.3013.9012.5011.109.708.30
10.2010.5010.8011.0011.3011.5011.6011.70
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K3. Limited SH 20K
4. Suction SH 20K + Fan5. Suction Gas Temperature 20°C + Fan + Liq. Inj.
53
6S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062
Model
6SHH-3500
6SJH-4000
6SKH-5000
-20
49.9047.4044.8042.3039.7037.2033.8031.1027.90
12.9013.7014.6015.4016.2016.9017.6018.3018.90
59.0055.6052.3049.0045.7042.4037.8034.3030.00
14.7015.7016.7017.7018.6019.4020.2020.9021.50
65.7063.1060.2057.3054.2051.0046.4043.0038.80
16.8018.1019.2020.3021.3022.3023.1023.9024.70
-15
61.5058.5055.6052.6049.6046.6043.6040.7036.8033.00
13.2014.3015.4016.4017.4018.4019.4020.2021.0021.80
73.1069.3065.5061.7057.8054.0050.2046.5041.4036.40
15.2016.5017.8019.0020.2021.4022.4023.4024.3025.10
82.4079.3075.9072.3068.6064.7060.8056.9051.5046.40
17.5019.1020.6022.1023.4024.7025.8026.9027.9028.80
-10
75.1071.6068.1064.6061.1057.6054.1050.5047.1042.8038.3036.8013.1014.5015.9017.3018.5019.8021.0022.1023.2024.1025.0025.4089.7085.3080.9076.5072.1067.6063.2058.8054.4049.0043.3041.5015.2016.9018.6020.1021.7023.1024.5025.8027.0028.1029.1029.40
102.5098.6094.6090.2085.7081.0076.2071.3066.4060.3054.0052.0017.7019.8021.7023.6025.3026.9028.4029.8031.0032.2033.3033.70
-5
90.9086.8082.7078.6074.5070.3066.1062.0057.8053.7049.6047.9012.8014.5016.2017.8019.4021.0022.4023.8025.2026.4027.6028.00
109.00104.0098.9093.7088.6083.4078.3073.1067.9062.8057.7055.7014.9016.9019.0020.9022.8024.7026.4028.0029.6031.0032.3032.80
126.00121.50116.50111.00105.50100.0094.1088.1082.1076.0070.0067.7017.4020.0022.4024.7026.8028.8030.7032.4034.1035.6036.9037.50
Evaporating Temperature oCCondensingTemperature
oC 0
109.00104.5099.6094.8089.9085.0080.1075.2070.3065.3060.4058.5012.0014.1016.1018.1020.0021.9023.7025.4027.1028.6030.0030.60
131.50125.50119.50113.50107.50101.5095.6089.6083.5077.5071.5069.1014.0016.5019.0021.3023.7025.9028.0030.1032.0033.8035.4036.10
153.00147.50142.00135.50129.00122.00115.00107.50100.5092.9085.5082.5016.5019.6022.6025.3027.9030.4032.7034.9036.9038.7040.5041.10
5
119.00113.50107.50102.0096.1090.3084.5078.7072.9070.60
15.7018.0020.3022.6024.7026.8028.8030.6032.4033.10
143.50136.50129.50122.50115.50108.50101.5094.4087.4084.60
18.5021.3024.1026.8029.3031.8034.1036.3038.4039.20
171.00163.50155.50147.50139.00130.00121.50112.50103.5099.70
22.1025.5028.6031.6034.3037.0039.4041.7043.8044.60
7
127.50121.50115.50109.50103.0097.0090.8084.6078.4075.90
15.4017.9020.4022.7025.1027.3029.4031.4033.3034.00
154.00146.50139.00132.00124.50117.00109.50102.0094.4091.40
18.2021.2024.1027.0029.7032.4034.9037.3039.5040.30
184.00176.00167.50158.50149.50140.00130.50121.00111.00107.50
21.8025.4028.7031.9034.9037.7040.3042.8045.1045.90
12.5
146.50139.00132.00124.50117.50110.00102.5095.1092.20
17.2020.1022.9025.7028.3030.9033.3035.6036.50
177.00168.50160.00151.00142.00133.50124.50115.50112.00
20.4023.9027.2030.5033.7036.7039.6042.3043.40
213.00203.00192.50181.50170.50159.00147.00135.00130.50
24.5028.5032.3035.9039.3042.5045.5048.3049.30
10
134.50128.00121.50114.50107.50101.0094.1087.2084.50
17.6020.3022.9025.4027.9030.2032.5034.6035.40
162.50154.50146.50138.50130.00122.00114.00105.50102.50
20.8024.1027.2030.2033.1035.9038.6041.1042.00
195.50186.50176.50166.50156.00145.50134.50124.00119.50
25.0028.7032.2035.5038.6041.6044.3046.9047.80
-25
40.2038.0035.7033.5031.3028.3025.9023.6020.80
12.4013.0013.6014.2014.8015.3015.8016.3016.80
47.0044.1041.1038.2035.3031.0027.9024.8020.90
14.0014.7015.4016.1016.7017.3017.8018.3018.70
51.8049.6047.2044.7042.1037.9035.1032.4029.00
15.8016.7017.5018.3019.1019.7020.3020.9021.50
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 10K + Fan
54
6S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550551015202530354045505510152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
6SLW-250E
6STW-320E
6SUW-4000
-40
23.1021.3019.5017.8016.0013.3011.609.908.306.709.609.8010.1010.3010.4010.4010.4010.4010.3010.1026.8024.8022.8020.8019.0015.4013.6011.8010.008.2011.7012.0012.3012.5012.7012.7012.7012.5012.2011.7032.6030.5028.3026.1023.8020.1017.8015.5013.4011.4014.1014.5014.9015.1015.3015.4015.5015.4015.3015.20
-35
30.2028.0025.9023.8021.7019.6017.6014.2012.1010.1011.0011.5011.8012.2012.4012.6012.7012.8012.8012.8035.6033.1030.7028.3025.9023.6021.3016.8014.4012.0013.3013.8014.3014.7015.1015.3015.5015.5015.4015.1042.6040.1037.5034.8032.1029.3026.6021.8019.1016.4016.1016.7017.3017.8018.2018.5018.7018.8018.9018.80
-30
38.7036.1033.6031.0028.5025.9023.4020.9018.5014.1012.4013.0013.6014.1014.5014.9015.2015.4015.6015.7046.1043.1040.1037.2034.3031.4028.5025.5022.6016.7014.8015.5016.2016.9017.4017.9018.3018.6018.7018.6054.4051.5048.4045.1041.8038.4035.0031.6028.2022.0017.9018.8019.6020.4021.0021.6022.0022.4022.6022.80
-25
48.8045.7042.6039.5036.4033.3030.3027.2024.1021.1013.7014.5015.3016.0016.6017.1017.6018.0018.4018.6058.3054.8051.2047.7044.1040.5037.0033.3029.6025.9016.2017.1018.1019.0019.8020.5021.1021.6022.0022.1068.4064.9061.1057.2053.2049.0044.8040.6036.3032.1019.5020.7021.8022.9023.8024.7025.4026.0026.5026.90
Evaporating Temperature oCCondensingTemperature
oC -20
56.8053.1049.4045.7041.9038.2034.4030.7026.90
15.9016.9017.8018.6019.4020.0020.6021.2021.60
68.2064.0059.8055.5051.2046.8042.4037.9033.30
18.6019.8020.9022.0023.0023.9024.7025.3025.70
80.5075.9071.2066.3061.3056.2051.0045.8040.50
22.3023.9025.3026.6027.8028.8029.8030.6031.30
-15
65.1060.7056.2051.8047.3042.8038.2033.70
18.3019.5020.5021.5022.4023.2024.0024.70
78.6073.6068.5063.4058.2053.0047.6042.10
21.3022.8024.2025.5026.6027.7028.6029.40
93.0087.3081.5075.5069.3063.0056.7050.30
25.7027.5029.2030.8032.2033.5034.7035.70
-10
73.5068.3063.0057.6052.3046.9039.30
20.9022.3023.5024.7025.7026.7027.60
89.3083.4077.3071.2065.0058.7049.20
24.5026.2027.8029.3030.7031.9033.00
106.0098.8091.7084.4076.9069.3058.40
29.5031.6033.6035.5037.2038.8040.20
-5
81.8075.6069.3063.0056.6048.90
23.8025.3026.7028.1029.3030.50
100.0093.0085.9078.7071.3062.00
28.0030.0031.8033.5035.1036.50
118.50110.00101.5092.7083.8072.80
33.8036.3038.6040.8042.8044.70
-45
17.5015.9014.4012.1010.609.107.706.30
8.108.308.408.408.408.308.208.10
19.7017.9016.3013.4011.9010.409.007.70
9.9010.1010.2010.3010.3010.209.909.60
24.5022.6020.7017.7015.6013.7011.8010.00
12.0012.2012.4012.5012.5012.5012.4012.30
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan
4. Limited SH 20K5. Liquid subcooling 0K
R404A /507R404A /507
55
6S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
202530354045505520253035404550552025303540455055202530354045505520253035404550552025303540455055
Model
6SHH-350E
6SJH-400E
6SKH-500E
-30
32.7030.3027.8025.3022.9020.4017.9015.4013.4013.8014.2014.4014.6014.6014.6014.4038.2035.3032.3029.3026.4023.5020.6017.9015.3015.7016.0016.4016.6016.7016.7016.5044.9041.4037.8034.3030.7027.3023.9020.7018.3018.9019.3019.6019.9020.0020.0019.80
-25
41.9039.0036.0033.0030.0027.0023.9020.9014.8015.5016.1016.5016.9017.1017.2017.2049.1045.7042.2038.6035.0031.4027.8024.4017.3017.9018.5019.0019.5019.8020.0020.0057.5053.4049.1044.9040.6036.4032.3028.2020.7021.5022.2022.7023.2023.5023.6023.60
-20
52.8049.3045.7042.0038.4034.7030.9027.2016.1017.1017.9018.6019.1019.6019.9020.1062.0057.9053.6049.3044.9040.5036.0031.6019.1020.0020.9021.6022.3022.9023.3023.5072.5067.5062.4057.3052.1046.9041.8036.6022.8023.9024.9025.8026.5027.1027.5027.70
-15
65.7061.4057.0052.6048.1043.6039.1034.5017.3018.5019.6020.5021.3022.0022.6023.0077.0072.1066.9061.7056.3050.8045.3039.8020.7021.9023.1024.2025.1025.9026.6027.0090.1084.1078.0071.7065.4059.1052.7046.3024.6026.1027.5028.8029.8030.7031.4031.90
Evaporating Temperature oCCondensingTemperature
oC -10
80.7075.5070.2064.9059.5054.0048.5042.9018.2019.7021.1022.3023.4024.4025.2025.9094.4088.5082.3075.9069.4062.7056.0049.3022.0023.6025.1026.5027.8028.9029.8030.60
110.50103.5096.0088.5080.9073.1065.4057.5026.0028.0029.8031.5032.9034.2035.3036.10
-5
98.0091.7085.4079.0072.5066.0059.4052.7018.7020.6022.3023.9025.3026.6027.7028.70
114.50107.5099.8092.2084.4076.4068.3060.1023.0025.0026.8028.6030.2031.7033.0034.00
134.50125.50117.00108.0098.6089.3080.0070.5026.8029.3031.7033.8035.8037.5039.0040.20
0
117.50110.50103.0095.2087.5079.8071.9064.0019.0021.2023.3025.3027.0028.7030.1031.40
137.00128.50120.00111.00101.5092.0082.4072.6023.5025.9028.2030.4032.4034.3035.9037.30
161.50151.00140.50130.00119.00108.0096.8085.5026.9030.0033.0035.7038.2040.4042.4044.10
7
149.50140.50131.00121.50112.00102.5092.5082.6018.6021.4024.1026.6028.9031.1033.0034.80
174.00163.50152.50141.00129.50117.50105.5093.2023.5026.5029.5032.3034.9037.4039.6041.50
205.00192.50179.50166.00152.50138.50124.50110.5025.7029.8033.7037.3040.6043.7046.4048.90
5
140.00131.50122.50113.50104.5095.4086.2076.9018.8021.4024.0026.3028.5030.4032.2033.90
163.00153.00142.50132.00121.00110.0098.4086.9023.6026.5029.2031.8034.3036.5038.6040.40
192.00180.00167.50155.00142.50129.00116.00102.5026.2030.0033.6037.0040.0042.8045.4047.60
-35
25.2023.1021.0018.90
11.8012.1012.3012.30
29.0026.4023.9021.30
13.2013.4013.6013.70
34.5031.3028.2025.10
15.9016.2016.5016.60
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 20°C + Fan3. Liquid subcooling 0K
R404A /507R404A /507
56
6S Series
50 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065
Model
6SHH-350E
6SJH-400E
6SKH-500E
-20
44.6042.3040.0037.6035.2032.8029.0026.5024.1021.70
10.4011.4012.3013.2014.0014.7015.3015.8016.3016.70
52.0049.8047.5045.0042.3039.6035.1032.0028.9025.70
12.8013.9014.9015.8016.5017.10
63.7059.7055.7051.7047.7043.6039.6035.6031.7027.80
15.3016.6017.8018.9019.9020.6021.1021.4021.3020.90
-15
56.5053.7050.8047.9044.9042.0039.0036.1031.7028.7025.70
11.0012.3013.5014.6015.5016.4017.2017.9018.5019.1019.50
66.1063.4060.5057.4054.2050.8047.3043.7038.3034.4030.50
13.5014.9016.3017.4018.5019.4020.1020.70
81.9077.2072.5067.7062.9058.2053.4048.7044.0039.3034.70
16.1017.7019.3020.7022.0023.1024.0024.7025.0025.1024.70
-10
70.7067.2063.7060.1056.5052.9049.2045.6041.9038.3033.4029.8011.4013.0014.4015.8017.0018.1019.1020.0020.8021.5022.0022.5083.1079.7076.1072.3068.3064.2059.9055.5050.9046.3040.0035.2013.7015.6017.3018.8020.2021.4022.5023.4024.2024.80
103.5098.0092.4086.7081.0075.3069.6063.9058.2052.6047.1041.6016.5018.5020.4022.2023.9025.4026.7027.8028.6029.1029.3029.00
-5
87.5083.3079.0074.6070.2065.8061.3056.8052.3047.9043.4039.0011.4013.3015.1016.7018.2019.6020.9022.0023.0023.9024.6025.30
103.0099.1094.6090.0085.1080.0074.7069.3063.7058.0052.3046.5013.4015.7017.9019.9021.7023.3024.7026.0027.1028.1028.8029.40
129.00122.50115.50109.00102.0095.3088.4081.6074.8068.0061.3054.7016.6018.9021.2023.4025.5027.4029.2030.7032.0033.0033.7033.90
Evaporating Temperature oCCondensingTemperature
oC 0
107.00102.0096.9091.7086.3080.9075.5070.0064.6059.1053.7048.3010.9013.2015.4017.4019.2020.9022.4023.8025.1026.2027.2028.00
127.00122.00116.50110.50104.5098.4092.0085.4078.6071.8064.8057.7012.5015.4018.0020.4022.7024.8026.7028.4029.8031.2032.3033.20
159.00151.00143.00135.00126.50118.50110.50102.0094.0085.9077.8069.8016.2018.9021.6024.2026.7029.1031.4033.4035.2036.7037.9038.70
5
124.00118.00111.50105.0098.6092.0085.5078.9072.3065.7059.20
12.7015.2017.6019.8021.8023.7025.4027.0028.4029.6030.70
148.00141.50134.50127.50120.00112.00104.0096.0087.7079.3070.70
14.3017.5020.5023.3025.8028.2030.4032.3034.0035.6036.90
184.00174.50164.50155.00145.50135.50126.00116.00106.5097.0087.40
18.4021.5024.6027.6030.5033.2035.8038.1040.1041.8043.20
7
127.00120.00113.50106.5099.4092.3085.2078.2071.1064.00
15.0017.6019.9022.1024.1025.9027.6029.2030.5031.70
152.50145.00137.50129.50121.00112.50103.5094.8085.7076.50
17.1020.3023.3026.1028.7031.0033.2035.1036.8038.30
188.00177.50167.50157.00146.50136.50126.00115.50105.5095.20
21.4024.7027.8030.9033.9036.6039.1041.4043.3045.00
15
160.50151.50142.50133.50124.00114.50105.5095.9086.60
16.6019.6022.5025.1027.5029.8031.9033.7035.40
194.00183.50173.00162.00150.50139.00127.50115.50103.50
18.6022.6026.3029.8033.0036.0038.8041.3043.50
237.00224.00211.00197.50184.00171.00157.50144.50131.00
24.0028.0031.9035.7039.3042.7045.9048.8051.50
12.5
147.00138.50130.50122.00113.50105.0096.2087.5078.90
17.1019.9022.5024.9027.2029.2031.1032.8034.30
177.50168.00158.00148.00138.00127.00116.50105.5094.30
19.4023.0026.4029.6032.5035.3037.7040.0042.00
217.00205.00193.00180.50168.00156.00143.50131.00119.00
24.3028.1031.7035.2038.6041.7044.6047.2049.50
10
142.00134.50126.50119.00111.00103.5095.5087.6079.7071.90
14.6017.4020.0022.4024.6026.7028.6030.3031.8033.20
170.50162.00153.50144.50135.00126.00116.00106.0096.1085.90
16.4019.9023.3026.4029.3031.9034.4036.6038.6040.40
210.00198.50187.50176.00164.50153.00141.50130.50119.00107.50
21.0024.6028.0031.4034.7037.7040.6043.2045.5047.50
-25
34.9033.0031.1029.1027.2023.8021.7019.7017.80
9.5010.3011.1011.7012.3012.8013.3013.7014.10
40.4038.6036.7034.6032.5028.5026.0023.5020.90
11.9012.7013.4014.0014.50
48.7045.3041.8038.3034.9031.4027.9024.5021.10
14.2015.3016.2017.0017.6018.0018.1018.0017.60
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 20K + Fan
57
6S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550551015202530354045505510152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
6SLW-2500
6STW-3200
6SUW-4000
-40
19.3018.1016.7015.4014.0012.5011.109.708.307.009.5010.0010.5010.9011.3011.6011.9012.1012.1012.1024.1022.2020.3018.5016.7014.9013.2011.609.908.4012.4012.7012.9013.0013.2013.3013.4013.6013.8014.1028.6027.0025.3023.5021.6019.6017.5015.4013.3011.2014.4014.9015.4015.9016.3016.7017.0017.3017.5017.50
-35
26.4024.9023.1021.4019.6017.8016.1014.3012.6010.8010.8011.4012.1012.7013.2013.7014.2014.5014.8014.9031.9029.8027.5025.2022.9021.0019.0017.0015.0013.1013.7014.2014.7015.1015.4015.8016.1016.5016.9017.3038.4036.5034.4032.1029.7027.1025.0022.3019.7017.0016.3017.1017.8018.5019.1019.8020.3020.7021.1021.30
-30
34.7032.9030.9028.7026.5024.3022.0020.2018.0015.8012.0012.8013.7014.5015.3016.0016.6017.1017.6017.9041.4038.8036.2033.5030.8028.2025.8023.6021.2018.9015.1015.8016.5017.1017.7018.3018.9019.4020.0020.7050.2048.0045.5042.8039.9036.8033.6030.9027.6024.2018.0019.1020.0021.0021.9022.8023.6024.3024.8025.30
-25
44.4042.2039.9037.5034.8032.2029.5026.8024.2021.9013.1014.2015.3016.3017.3018.2019.0019.8020.4020.9052.6049.6046.6043.6040.4037.3034.2031.2028.4026.0016.4017.4018.3019.2020.1020.9021.7022.5023.3024.2064.4061.8058.8055.6052.2048.5044.7040.6036.5033.1019.5020.8022.2023.4024.6025.8026.9027.8028.7029.50
Evaporating Temperature oCCondensingTemperature
oC -20
55.4052.9050.3047.5044.7041.4038.3035.2032.0028.8014.1015.4016.7018.0019.2020.3021.4022.4023.2024.0065.8062.4058.9055.3051.8048.0044.4040.8037.3034.0017.7019.0020.2021.4022.5023.6024.7025.7026.8027.9081.2078.1074.6070.8066.8062.4057.8053.1048.1043.0020.7022.4024.0025.7027.2028.7030.1031.4032.6033.70
-15
67.9065.1062.1058.9055.7052.3048.9044.9041.3037.6014.8016.4018.0019.5021.0022.4023.7024.9026.0027.0081.1077.1073.1069.0065.0060.9056.8052.3048.2044.1019.0020.6022.2023.6025.0026.4027.7029.0030.4031.70
100.5097.1093.0088.6083.9078.8073.4067.8061.9055.9021.5023.6025.7027.7029.7031.5033.3035.0036.6038.00
-10
81.8078.6075.3071.8068.1064.3060.5056.5052.4047.9015.2017.1018.9020.7022.5024.1025.7027.2028.6029.8098.7094.1089.5084.8080.1075.5070.8066.1061.5056.3020.3022.3024.1025.9027.6029.3030.9032.5034.1035.70
123.00119.00114.50109.00103.5097.8091.6085.1078.2071.2021.9024.5027.0029.5031.9034.2036.4038.5040.5042.30
-5
97.2093.7090.0086.1082.0077.8073.5069.0064.5059.9015.2017.4019.5021.6023.6025.6027.5029.3030.9032.40
118.50113.50108.00103.0097.5092.2086.8081.5076.1070.8021.7024.0026.2028.3030.4032.3034.3036.2038.0039.90
149.00144.00138.50132.50126.50119.50112.50105.0097.3089.1021.9024.9028.0030.9033.8036.6039.3041.8044.3046.60
-45
13.5012.5011.5010.409.308.307.206.20
8.408.709.009.209.509.609.809.80
17.7016.1014.5013.0011.5010.008.607.20
11.1011.1011.1011.0010.9010.9010.8010.80
20.9019.5018.0016.4014.8013.1011.409.70
12.3012.6012.9013.2013.5013.7013.9014.00
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K3. Limited SH 20K
4. Suction SH 20K + Fan5. Suction Gas Temperature 20°C + Fan + Liq. Inj.
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 10K + Fan
58
6S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062101520253035404550556062
Model
6SHH-3500
6SJH-4000
6SKH-5000
-20
58.9055.9052.9049.9046.9043.9039.9036.7032.90
15.5016.5017.5018.4019.4020.3021.1021.9022.70
69.6065.7061.7057.8053.9050.0044.6040.5035.40
17.7018.9020.0021.2022.3023.3024.2025.0025.80
77.5074.4071.1067.6063.9060.2054.7050.8045.80
20.1021.6023.0024.4025.6026.7027.8028.7029.60
-15
72.6069.1065.6062.0058.5055.0051.5048.0043.4038.90
15.8017.1018.4019.7020.9022.1023.2024.3025.3026.10
86.3081.8077.3072.8068.3063.8059.3054.8048.8043.00
18.2019.8021.3022.8024.3025.6026.9028.1029.1030.10
97.3093.6089.6085.4081.0076.4071.8067.1060.8054.70
20.9022.9024.8026.5028.1029.6031.0032.3033.5034.60
-10
88.6084.5080.4076.3072.1067.9063.8059.6055.5050.5045.2043.5015.8017.4019.1020.7022.2023.7025.2026.5027.8029.0030.0030.40
106.00100.5095.5090.3085.0079.8074.6069.4064.2057.8051.1048.9018.3020.3022.2024.2026.0027.8029.4031.0032.4033.7034.9035.30
121.00116.50111.50106.50101.0095.6089.9084.1078.4071.2063.8061.4021.2023.7026.1028.3030.3032.3034.1035.7037.3038.7040.0040.50
-5
107.00102.5097.6092.8087.9083.0078.1073.1068.2063.4058.5056.6015.3017.4019.4021.4023.3025.1026.9028.6030.2031.7033.1033.60
128.50122.50116.50110.50104.5098.4092.3086.2080.2074.1068.1065.7017.8020.3022.7025.1027.4029.6031.7033.7035.5037.2038.8039.30
148.50143.00137.50131.00124.50118.00111.00104.0096.9089.7082.6079.8020.8023.9026.9029.6032.2034.6036.8038.9040.9042.7044.3045.00
Evaporating Temperature oCCondensingTemperature
oC 0
129.00123.00117.50112.00106.00100.5094.5088.7082.9077.1071.3069.0014.4016.9019.3021.7024.0026.3028.4030.5032.5034.3036.0036.70
155.00148.00141.00134.00127.00120.00113.00105.5098.6091.5084.4081.6016.8019.8022.7025.6028.4031.1033.6036.1038.4040.5042.5043.30
181.00174.50167.50160.00152.00144.00135.50127.00118.50109.50101.0097.4019.8023.5027.1030.4033.5036.5039.3041.8044.2046.5048.6049.30
5
140.50134.00127.00120.50113.50106.5099.7092.9086.1083.30
18.8021.6024.4027.1029.7032.2034.5036.8038.9039.70
169.00161.00153.00144.50136.50128.00119.50111.50103.0099.80
22.2025.6028.9032.1035.2038.1040.9043.6046.0047.00
202.00193.00183.50174.00164.00153.50143.00132.50122.00117.50
26.6030.6034.3037.9041.2044.3047.3050.0052.6053.50
7
150.50143.50136.00129.00122.00114.50107.0099.8092.5089.60
18.4021.5024.4027.3030.1032.7035.3037.7040.0040.80
181.50173.00164.50155.50146.50138.00129.00120.00111.50108.00
21.8025.4029.0032.4035.7038.8041.9044.7047.4048.40
217.00208.00197.50187.00176.50165.50154.00142.50131.00126.50
26.2030.4034.5038.3041.8045.2048.4051.3054.1055.10
12.5
172.50164.00155.50147.00138.50129.50121.00112.50109.00
20.6024.1027.5030.8034.0037.1040.0042.7043.80
209.00199.00188.50178.00168.00157.50147.00136.50132.00
24.4028.6032.7036.6040.4044.0047.5050.8052.00
252.00240.00227.00214.00201.00187.50173.50159.50154.00
29.4034.2038.8043.1047.2051.0054.6057.9059.20
10
159.00151.00143.00135.00127.00119.00111.00103.0099.70
21.1024.3027.5030.5033.5036.3039.0041.5042.50
192.00182.50173.00163.50153.50144.00134.00124.50120.50
25.0028.9032.6036.3039.8043.1046.3049.3050.40
231.00220.00208.00196.50184.00171.50159.00146.00141.00
30.0034.4038.7042.6046.4049.9053.2056.2057.40
-25
47.4044.8042.2039.6037.0033.4030.6027.9024.60
14.8015.6016.3017.0017.7018.4019.0019.6020.10
55.5052.0048.5045.1041.7036.6032.9029.2024.70
16.8017.7018.5019.3020.0020.8021.4021.9022.40
61.1058.5055.7052.7049.7044.8041.4038.2034.20
18.9020.0021.0021.9022.8023.7024.4025.1025.80
59
6S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550551015202530354045505510152025303540455055101520253035404550551015202530354045505510152025303540455055
Model
6SLW-250E
6STW-320E
6SUW-400E
-40
27.3025.1023.0020.9018.9015.7013.6011.709.808.0011.5011.8012.1012.3012.4012.5012.5012.4012.3012.2031.7029.2026.8024.6022.4018.2016.0013.9011.809.7014.0014.4014.7015.0015.2015.3015.2015.0014.6014.0038.5036.0033.4030.8028.1023.7020.9018.3015.8013.4017.0017.4017.8018.1018.4018.5018.6018.5018.4018.20
-35
35.6033.1030.5028.0025.6023.2020.8016.7014.3011.9013.2013.8014.2014.6014.9015.1015.3015.4015.4015.4042.0039.1036.2033.4030.6027.9025.1019.8017.0014.2016.0016.6017.1017.6018.1018.4018.6018.6018.5018.1050.2047.3044.2041.1037.9034.6031.4025.7022.5019.3019.3020.1020.7021.3021.8022.1022.4022.6022.6022.60
-30
45.7042.6039.6036.6033.6030.6027.6024.7021.8016.6014.9015.6016.3016.9017.4017.8018.2018.5018.7018.8054.4050.9047.4043.9040.5037.0033.6030.1026.6019.7017.8018.6019.5020.2020.9021.5021.9022.2022.4022.3064.2060.7057.1053.3049.3045.4041.3037.3033.3026.0021.5022.6023.5024.4025.2025.9026.4026.8027.1027.30
-25
57.5053.9050.3046.6043.0039.3035.7032.1028.5024.9016.4017.4018.4019.2019.9020.5021.1021.6022.0022.3068.9064.6060.4056.2052.1047.8043.6039.3035.0030.5019.4020.5021.7022.7023.7024.6025.3025.9026.3026.6080.8076.5072.1067.5062.7057.9052.9047.9042.9037.8023.3024.8026.2027.5028.6029.6030.5031.2031.9032.30
Evaporating Temperature oCCondensingTemperature
oC -20
67.0062.6058.3053.9049.5045.1040.6036.2031.80
19.1020.2021.3022.3023.2024.1024.8025.4026.00
80.5075.5070.5065.5060.4055.3050.1044.8039.30
22.3023.7025.1026.4027.6028.7029.6030.4030.90
94.9089.6084.0078.3072.3066.3060.2054.0047.80
26.8028.6030.3031.9033.3034.6035.7036.7037.50
-15
76.8071.6066.4061.1055.8050.5045.1039.80
21.9023.3024.6025.8026.9027.9028.8029.60
92.8086.9080.9074.8068.7062.5056.2049.70
25.6027.3029.0030.5032.0033.2034.3035.20
109.50103.0096.2089.1081.8074.4066.9059.30
30.8033.0035.0036.9038.7040.2041.6042.80
-10
86.8080.5074.3068.0061.7055.3046.30
25.1026.7028.2029.6030.9032.1033.20
105.5098.4091.3084.1076.7069.3058.00
29.4031.4033.3035.1036.8038.3039.60
125.00116.50108.0099.5090.7081.8069.00
35.3037.9040.3042.6044.7046.5048.20
-5
96.5089.2081.8074.3066.8057.70
28.5030.4032.1033.7035.2036.60
118.00110.00101.5092.9084.2073.20
33.6036.0038.2040.2042.1043.80
140.00130.00120.00109.5098.8085.90
40.5043.5046.4049.0051.4053.60
-45
20.6018.8016.9014.3012.5010.709.007.50
9.809.9010.1010.1010.1010.009.909.70
23.2021.1019.2015.8014.0012.3010.709.10
11.9012.1012.3012.3012.3012.2012.0011.50
28.9026.7024.4020.8018.5016.1013.9011.80
14.4014.7014.8015.0015.0015.0014.9014.70
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 0°C3. Suction Gas Temperature 0°C + Fan
4. Limited SH 20K5. Liquid subcooling 0K
R404A /507R404A /507
60
6S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
202530354045505520253035404550552025303540455055202530354045505520253035404550552025303540455055
Model
6SHH-350E
6SJH-400E
6SKH-500E
-30
38.6035.7032.8029.9027.0024.0021.1018.2016.0016.6017.0017.3017.5017.6017.5017.3045.0041.6038.1034.6031.1027.7024.3021.1018.3018.8019.3019.6019.9020.0020.0019.9053.0048.8044.6040.4036.3032.2028.3024.4022.0022.6023.1023.5023.8024.0023.9023.80
-25
49.5046.0042.5038.9035.4031.8028.2024.6017.8018.6019.3019.8020.2020.5020.6020.7057.9053.9049.8045.6041.3037.1032.9028.8020.7021.5022.2022.8023.3023.7023.9023.9067.9063.0058.0053.0048.0043.0038.1033.3024.8025.8026.6027.3027.8028.2028.4028.40
-20
62.4058.2053.9049.6045.3040.9036.5032.1019.4020.5021.4022.3022.9023.5023.9024.1073.1068.3063.3058.2053.0047.7042.5037.3022.9024.0025.0026.0026.8027.4027.9028.2085.6079.7073.7067.6061.5055.4049.3043.2027.3028.7029.9031.0031.8032.5033.0033.20
-15
77.6072.5067.3062.1056.8051.5046.1040.7020.7022.2023.5024.6025.6026.4027.1027.6090.9085.0079.0072.8066.4060.0053.5047.0024.8026.3027.7029.0030.1031.1031.9032.40
106.5099.2092.0084.7077.2069.7062.2054.7029.5031.4033.1034.5035.8036.8037.7038.30
Evaporating Temperature oCCondensingTemperature
oC -10
95.2089.1082.9076.6070.2063.7057.2050.6021.8023.6025.3026.8028.1029.3030.3031.10
111.50104.5097.1089.6081.9074.0066.1058.1026.4028.3030.1031.8033.3034.7035.8036.70
130.50122.00113.50104.5095.4086.3077.1067.9031.1033.6035.8037.8039.5041.0042.3043.30
-5
115.50108.00101.0093.2085.6077.9070.1062.2022.5024.7026.8028.7030.4031.9033.3034.40
135.00126.50118.00109.0099.6090.2080.6070.9027.6030.0032.2034.3036.3038.0039.5040.80
158.50148.00138.00127.00116.50105.5094.3083.2032.1035.2038.0040.6042.9045.0046.7048.20
0
139.00130.00121.50112.50103.5094.1084.8075.5022.7025.4028.0030.3032.4034.4036.1037.60
162.00152.00141.50131.00120.00108.5097.2085.7028.2031.1033.9036.5038.9041.1043.1044.80
190.50178.50166.00153.50140.50127.50114.00101.0032.3036.1039.6042.8045.8048.5050.8052.90
7
176.50165.50154.50143.50132.00120.50109.0097.5022.3025.7028.9031.9034.7037.3039.6041.70
205.00193.00180.00166.50153.00138.50124.50110.0028.2031.9035.4038.7041.9044.8047.5049.80
242.00227.00212.00196.00180.00163.50147.00130.0030.8035.8040.4044.7048.7052.4055.7058.70
5
165.00155.00144.50134.00123.50112.50102.0090.8022.5025.7028.7031.5034.1036.5038.7040.60
192.50180.50168.00155.50143.00129.50116.00102.5028.3031.8035.1038.2041.1043.8046.3048.40
227.00212.00198.00183.00168.00152.50137.00121.0031.5036.1040.4044.4048.0051.4054.4057.20
-35
29.7027.2024.8022.30
14.2014.5014.7014.80
34.2031.2028.1025.10
15.8016.1016.3016.40
40.7037.0033.3029.70
19.1019.5019.8020.00
Notes:1. Suction Gas Temperature 20°C2. Suction Gas Temperature 20°C + Fan3. Liquid subcooling 0K
R404A /507R404A /507
61
6S Series
60 Hz
Q
P
Q
P
Q
P
Performance DataQ=Capacity (kW) P=Power input (kW)
101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065101520253035404550556065
Model
6SHH-350E
6SJH-400E
6SKH-500E
-20
52.7050.0047.2044.4041.6038.7034.3031.3028.4025.60
12.5013.7014.8015.8016.7017.6018.3019.0019.5020.00
60.7058.0055.0051.8048.5045.0041.4037.8034.1030.30
15.4016.7017.9018.9019.8020.5021.1021.6021.9022.00
75.7071.4067.0062.6058.2053.8046.8042.1037.4032.80
18.4019.9021.4022.7023.8024.7025.4025.7025.6025.10
-15
66.6063.3059.9056.5053.0049.5046.0042.6037.4033.8030.30
13.2014.8016.2017.5018.7019.7020.6021.5022.2022.8023.40
77.6074.3070.7066.8062.8058.6054.2049.8045.2040.6036.00
16.2017.9019.5020.9022.1023.2024.1024.9025.5025.9026.10
96.9091.6086.4081.0075.7070.4065.1059.8051.9046.4041.00
19.3021.2023.1024.8026.4027.7028.8029.6030.0030.1029.70
-10
83.4079.3075.2071.0066.7062.4058.1053.8049.5045.2039.4035.1013.6015.5017.3018.9020.4021.7022.9024.0024.9025.8026.5027.0097.9093.8089.4084.7079.9074.8069.5064.1058.6052.9047.2041.5016.4018.7020.7022.6024.2025.7027.0028.1029.1029.8030.3030.70
122.50116.00109.50103.0096.5090.0083.5077.0070.6064.2055.5049.1019.8022.2024.4026.6028.6030.5032.1033.4034.3034.9035.1034.80
-5
103.0098.3093.2088.1082.9077.6072.3067.0061.8056.5051.2046.1013.6015.9018.1020.0021.9023.5025.0026.4027.6028.7029.6030.30
122.00117.00111.50106.00100.0093.8087.5081.0074.3067.5060.6053.6016.1018.9021.4023.8026.0027.9029.7031.2032.5033.7034.6035.30
152.50144.50137.00129.00121.00113.00105.0097.2089.3081.5073.7065.9019.9022.7025.4028.1030.6032.9035.0036.9038.4039.6040.4040.70
Evaporating Temperature oCCondensingTemperature
oC 0
126.50120.50114.50108.00102.0095.5089.1082.7076.2069.8063.3057.0013.1015.9018.4020.8023.0025.0026.9028.6030.1031.4032.6033.60
149.50143.50137.00130.50123.50116.00108.50101.0092.8084.7076.4068.1015.0018.4021.6024.5027.2029.7032.0034.0035.8037.4038.7039.80
187.50178.00168.50159.00149.50140.00130.00120.50111.00101.5091.8082.4019.4022.7025.9029.0032.1035.0037.7040.1042.2044.0045.4046.40
5
146.50139.00131.50124.00116.50108.50101.0093.1085.3077.5069.80
15.2018.3021.1023.7026.2028.4030.5032.3034.0035.5036.80
174.50167.00159.00150.50142.00133.00124.00114.50105.0095.0085.10
17.2021.0024.6027.9031.0033.8036.4038.8040.8042.7044.30
217.00206.00194.00182.50171.00159.00147.50136.00124.00112.50101.00
22.1025.8029.5033.1036.6039.9042.9045.7048.1050.2051.90
7
150.00142.00133.50125.50117.50109.00100.5092.2083.9075.50
18.0021.0023.9026.5028.9031.1033.2035.0036.6038.00
180.00171.50162.50153.00143.50134.00124.00113.50103.5092.70
20.5024.4028.0031.3034.4037.3039.8042.1044.2046.00
222.00210.00197.00184.50172.00159.50147.00134.50122.00109.50
25.7029.6033.4037.1040.6043.9046.9049.7052.0054.00
15
189.50179.00168.00157.50146.50135.50124.50113.00102.00
19.9023.5026.9030.1033.1035.8038.2040.5042.50
228.00217.00205.00193.00180.50168.00155.00141.50128.50
22.3027.1031.5035.7039.6043.2046.5049.5052.30
281.00264.00247.00231.00214.00197.00180.50163.50147.00
28.8033.6038.3042.8047.2051.3055.1058.6061.70
12.5
173.50163.50154.00144.00133.50123.50113.50103.5093.20
20.4023.8027.0029.9032.6035.1037.3039.4041.20
209.00199.00188.00176.50165.00153.00141.00128.50116.50
23.2027.6031.7035.5039.1042.3045.3048.0050.40
257.00242.00226.00211.00195.50180.00165.00149.50134.50
29.2033.7038.1042.3046.3050.1053.5056.7059.40
10
167.50158.50149.50140.50131.00122.00112.50103.5094.1084.80
17.5020.8023.9026.8029.5032.0034.3036.3038.2039.80
201.00191.50181.50171.50161.00150.50139.50128.00116.50105.00
19.6023.9027.9031.6035.1038.3041.3043.9046.3048.40
248.00234.00220.00206.00192.50178.50164.50150.50136.50122.50
25.2029.5033.7037.7041.6045.3048.7051.8054.6057.00
-25
41.2038.9036.7034.4032.1028.1025.7023.3020.90
11.4012.4013.3014.1014.8015.4016.0016.5016.90
46.8044.5042.0039.3036.6033.7030.7027.7024.70
14.2015.2016.0016.8017.3017.8018.1018.4018.40
58.4054.7051.0047.3043.5037.0032.9028.9024.90
17.1018.3019.4020.3021.1021.5021.7021.6021.00
Notes:1. Suction Gas Temperature 20°C2. Liquid subcooling 0K
3. Suction Superheat 20K4. Suction Superheat 20K + Fan
62
4S Series
Dimensional Drawing
SL – Suction line (rotalock) DL – Discharge line (rotalock)
8. Connection oil-pressure control H. P. 1/4”≈6mm
9. Plug oil-pressure control L. P. 1/4”-18NPTF
10. Oil Pressure Switch sensor connection ¾”-16UNF
11. Plug -crankcase heater 1/2”-14NPSL
12.DTC valve plug connection (used for 60Hz compressor) 1/2”-14NPTF
13.Liquid injection adapter connection ¼” – 18NPTF
1. Plug low-pressure connection 1/8”-27NPTF
2. Oil screen built in
3. Magnetic plug 1”-16UN
4. Plug oil charge 1/4”-18NPTF
5. Oil-pressure connection 7/16”-20UNF
6. Plug high-pressure connection 1/8”-27NPTF
7. DTC valve plug connection 1/2”-14NPTF (used for 50Hz compressor)
A
680 mm
725 mm
B
600 mm
635 mm
C
55 mm
65 mm
D
155 mm
200 mm
M
485 mm
490 mm
N
205 mm
210 mm
Model
4SLW-1500/4SLW-150E
4STW-2000/4STW-200E
6
54
2,3
78
910
11
12
13
Section G
G
4SLW-1500, 4SLW-150E, 4STW-2000 & 4STW-200E
63
4S Series
Dimensional Drawing
SL – Suction line (rotalock) DL – Discharge line (rotalock)
7. Plug high-pressure connection 1/8”-27NPTF
8. Connection oil-pressure control H. P. 1/4”≈6mm
9. Plug oil-pressure control L. P. 1/4”-18NPTF
10. Oil Pressure Switch sensor connection ¾”-16UNF
11. Plug -crankcase heater 1/2”-14NPSL
1. Plug low-pressure connection 1/8”-27NPTF
2. Oil screen built in
3. Magnetic plug 1”-16UN
4. Plug oil charge 1/4”-18NPTF
5. Oil-pressure connection 7/16”-20UNF
6. Plug high-pressure connection 1/8”-27NPTF
A
650 mm
670 mm
690 mm
C
55 mm
65 mm
65 mm
D
155 mm
180 mm
200 mm
E
360 mm
380 mm
380 mm
F
450 mm
450 mm
450 mm
G
495 mm
495 mm
495 mm
Model
4SAH-2000/4SAH-200E
4SHH-2500/4SHH-250E
4SJH-3000/4SJH-300E
4SAH-2000, 4SAH-200E, 4SHH-2500, 4SHH-250E, 4SJH-3000 & 4SJH-300E
6
5
42,3
789
1011
M
485 mm
490 mm
515 mm
N
205 mm
210 mm
230 mm
1
64
6S Series
Dimensional Drawing
SL – Suction line(rotalock) DL – Discharge line(rotalock)
6SLW-2500, 6SLW-250E, 6SHH-3500 & 6SHH-350E
1G
7
654
2,3
8 910
11
12
131415
16
Section G
9. Plug high-pressure connection 1/8”-27NPTF
10. Liquid injection adapter connection 3/8”-18NPTF
11. Plug high-pressure connection 1/4”-18NPTF
12. Plug high-pressure connection 1/8”-27NPTF
13. Oil Pressure Switch sensor connection ¾”-16UNF
14. Plug oil-pressure control L. P. 1/4”-18NPTF
15. Plug -crankcase heater 12.7mm
1. Plug low-pressure connection 1/8”-27NPTF
2. Oil screen built in
3. Magnetic plug 1”-16UN
4. Plug oil charge 1/4”-18NPTF
5. Liquid injection adapter connection 1/4”-18NPTF
6. Oil-pressure connection 7/16”-20UNF
7. Plug high-pressure connection 1/8”-27NPTF
8. Oil-pressure control H. P. 1/4”≈6mm
65
6S Series
Dimensional Drawing
SL – Suction line (rotalock) DL – Discharge line (rotalock)
A
740 mm
760 mm
B
655 mm
675 mm
D
215 mm
235 mm
M
540 mm
565 mm
Model
6STW-3200/6STW-320E
6SJH-4000/6SJH-400E
6SJH-4000/6SJH-400E , & 6STW-3200/6STW-320E
16
Section G
1G
7
654
2,3
8 9 1011
12
131415
1. Plug low-pressure connection 1/8”-27NPTF
2. Oil screen built in
3. Magnetic plug 1”-16UN
4. Plug oil charge 1/4”-18NPTF
5. Liquid injection adapter connection 1/4”-18NPTF
6. Oil-pressure connection 7/16”-20UNF
7. Plug high-pressure connection 1/8”-27NPTF
8. Oil-pressure control H. P. 1/4”≈6mm
9. Plug high-pressure connection 1/8”-27NPTF
10. Liquid injection adapter connection 3/8”-18NPTF
11. Plug high-pressure connection 1/4”-18NPTF
12. Plug high-pressure connection 1/8”-27NPTF
13. Oil Pressure Switch sensor connection ¾”-16UNF
14. Plug oil-pressure control L. P. 1/4”-18NPTF
15. Plug -crankcase heater 12.7mm
16. DTC valve plug connection (used for 6STW compressor) 1/2”-14NPTF
66
6S Series
Dimensional Drawing
SL – Suction line (rotalock) DL – Discharge line (rotalock)
6SKH-5000/6SKH-500E & 6SUW-4000/6SUW-400E
16
Section G
G
771670 61
SL1
DL
381(6SU)457(6SK)
76 190
315
130
430 48
554
0
12
14
1110
9
13
15
2,3
4568
7
305315
570
65 124
1. Plug low-pressure connection 1/8”-27NPTF
2. Oil screen built in
3. Magnetic plug 1”-16UN
4. Plug oil charge 1/4”-18NPTF
5. Liquid injection adapter connection 1/4”-18NPTF
6. Oil-pressure connection 7/16”-20UNF
7. Plug high-pressure connection 1/8”-27NPTF
8. Oil-pressure control H. P. 1/4”≈6mm
9. Plug high-pressure connection 1/8”-27NPTF
10. Liquid injection adapter connection 3/8”-18NPTF
11. Plug high-pressure connection 1/4”-18NPTF
12. Plug oil-pressure control L. P. 1/4”-18NPTF
13. Oil Pressure Switch sensor connection ¾”-16UNF
14. Plug oil-pressure control L. P. 1/4”-18NPTF
15. Plug -crankcase heater Ø1/2”=12.7mm
16. DTC valve plug connection (used for 6SUW compressor) 1/2”-14NPTF
67
Wiring Diagram
4S/6S Series
Electrical diagram for direct start
Electrical diagram For Part winding Start (AWM/D model)
Control Circuit 220-240V 50/60Hz
Control Circuit 220-240V 50/60Hz
68
Wiring Diagram
Electrical diagram For Y-∆ Start (EWK Model)
4S/6S Series
Electrical Diagram Coding
A1: Motor protector module
A2: Oil Differential Pressure Switch OPS2
D1: Operating recognition Connection;
E: Grounding Connection
E1: Crankcase Heater
E2-E3: Thermal protection switch for fan
K11: Time delay relay 1-3s for Y/∆start
K12: Time delay relay 1s±0.1s for Part-winding Start
K1-K4: contactor M1
K5,K55: Fan contactor
K6: Thermostat
M: Compressor motor
Q1: Mini-breaker
Q2: Mini-breaker
S1: Control Switch
Y1: H/L pressure switches
L1, L2, L3: Voltage Connection
380-420V-3-50 Hz -PW
380-420V-3-60Hz-Y
220-240V-3-60Hz-Delta
440-480V-3-60Hz-PW
Color code
VT: violet
OG: orange
GY: grey
BN: brown
BU: blue
PK: pink
Control Circuit 220-240V 50/60Hz
69
Terminal Jumper Schematics
4S/6S Series
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
1(U) 2(V) 3(W)
7(Z) 8(X) 9(Y)
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
E.4.01.00 E.4.02.00
E.4.03.00
E.4.05.00E.4.01.00
Direct-On-Line Start Direct-On-Line StartY
Star-Delta-StartY-
Part-Winding Start, first Start Step 1-2-3Y-Y
Direct-On-Line StartY-Y
Star-Delta-MotorY-
Code E
Star-WindingMotor:
Y-YCode A
70
4S Series
Motor Current Data (A)
-45
10.2
14.4
13.7
16.2
12.9
18.1
17.3
20.4
-40
12.6
16.0
15.3
18.0
15.8
20.2
19.3
22.7
-35
14.8
17.7
17.2
20.1
18.6
22.4
21.6
25.4
-30
16.9
19.6
17.6
21.9
23.2
19.1
22.4
21.3
24.6
22.2
27.6
29.2
24.1
28.3
-25
17.1
20.4
23.2
19.0
21.5
18.9
23.7
25.5
21.2
24.9
15.7
19.0
20.9
21.6
25.7
29.3
23.9
27.0
23.8
29.8
32.1
26.7
31.4
19.8
23.9
26.4
-20
18.5
22.1
25.8
20.9
23.4
20.3
25.5
27.8
23.4
27.5
17.0
20.9
26.4
23.3
27.8
32.5
26.4
29.5
25.5
32.1
35.1
29.4
34.6
21.4
26.3
29.8
-15
19.7
23.7
28.1
22.8
25.5
21.6
27.3
30.2
25.5
30.2
18.2
22.6
26.1
24.9
29.9
35.3
28.7
32.2
27.2
34.3
38.1
32.2
38.0
23.0
28.5
32.9
-10
20.8
25.2
30.1
24.6
27.7
22.9
29.0
32.5
27.6
32.9
19.3
24.2
28.3
26.2
31.8
37.9
31.0
34.9
28.9
36.5
40.9
34.8
41.5
24.4
30.5
35.7
-5
21.7
26.6
31.8
26.3
30.0
24.1
30.6
34.5
29.6
35.7
20.3
25.6
30.2
27.4
33.5
40.1
33.1
37.8
30.4
38.6
43.5
37.3
44.9
25.6
32.3
38.1
0
22.5
27.8
33.3
25.1
32.1
36.3
21.2
26.9
31.9
28.3
35.0
41.9
31.7
40.4
45.8
26.7
33.9
40.1
5
23.1
28.7
34.5
25.9
33.3
37.7
21.9
28.1
33.2
29.1
36.1
43.4
32.6
41.9
47.5
27.6
35.4
41.8
7
23.3
29.0
34.9
26.1
33.7
38.1
22.2
28.5
33.7
29.3
36.5
43.9
32.9
42.5
48.0
28.0
35.9
42.4
15
23.1
29.9
35.1
29.1
37.7
44.2
12.5
23.7
29.4
35.8
22.8
29.5
34.7
29.8
37.1
45.1
28.8
37.2
43.7
10
23.5
29.3
35.4
22.6
29.1
34.3
29.6
36.9
44.6
28.4
36.6
43.2
4SAH-2000
4SHH-2500
4SJH-3000
4SLW-1500
4STW-2000
4SAH-200E
4SHH-250E
4SJH-300E
4SLW-150E
4STW-200E
4SAH-200E
4SHH-250E
4SJH-300E
4SAH-2000
4SHH-2500
4SJH-3000
4SLW-1500
4STW-2000
4SAH-200E
4SHH-250E
4SJH-300E
4SLW-150E
4STW-200E
4SAH-200E
4SHH-250E
4SJH-300E
R22 (400V-3-50Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R22 (380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R407C (380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R407C (400V-3-50Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (400V-3-50Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
71
4S Series
Motor Current Data (A)
-45
10.2
14.4
14.0
16.2
21.5
30.2
29.4
34.0
-40
12.6
16.0
15.4
18.0
26.4
33.6
32.3
37.9
-35
14.8
17.7
16.9
20.1
31.1
37.3
35.5
42.3
-30
16.9
19.6
17.6
21.9
23.2
18.5
22.4
35.6
41.1
37.0
46.1
48.7
38.8
47.1
-25
17.1
20.4
23.2
19.0
21.5
18.9
23.7
25.5
20.2
24.9
15.7
19.0
20.9
36.0
42.8
48.8
39.9
45.1
39.7
49.7
53.5
42.4
52.3
32.9
39.8
44.0
-20
18.5
22.1
25.8
20.9
23.4
20.3
25.5
27.8
21.8
27.5
17.0
20.9
23.7
38.9
46.4
54.1
44.0
49.2
42.6
53.5
58.5
45.9
57.7
35.7
43.8
49.7
-15
19.7
23.7
28.1
22.8
25.5
21.6
27.3
30.2
23.5
30.2
18.2
22.6
26.1
41.4
49.8
58.9
47.9
53.6
45.4
57.3
63.4
49.3
63.3
38.3
47.5
54.9
-10
20.8
25.2
30.1
24.6
27.7
22.9
29.0
32.5
25.0
32.9
19.3
24.2
28.3
43.7
53.0
63.1
51.6
58.2
48.2
60.9
68.2
52.5
69.1
40.6
50.8
59.5
-5
21.7
26.6
31.8
26.3
29.0
24.1
30.6
34.5
26.3
35.7
20.3
25.6
30.2
45.6
55.9
66.8
55.2
60.9
50.7
64.3
72.5
55.3
74.9
42.7
53.8
63.5
0
22.5
27.8
33.3
25.1
32.1
36.3
21.2
26.9
31.9
47.2
58.3
69.9
52.8
67.4
76.3
44.5
56.5
66.9
5
23.1
28.7
34.5
25.9
33.3
37.7
21.9
28.1
33.2
48.4
60.2
72.4
54.4
69.9
79.2
46.1
58.9
69.7
7
23.3
29.0
34.9
26.1
33.7
38.1
22.2
28.5
33.7
48.9
60.8
73.2
54.9
70.8
80.1
46.6
59.8
70.7
15
23.1
29.9
35.1
48.5
62.8
73.6
12.5
23.7
29.4
35.8
22.8
29.5
34.7
49.7
61.8
75.1
47.9
61.9
72.9
10
23.5
29.3
35.4
22.6
29.1
34.3
49.4
61.5
74.3
47.4
61.0
72.0
4SAH-2000
4SHH-2500
4SJH-3000
4SLW-1500
4STW-2000
4SAH-200E
4SHH-250E
4SJH-300E
4SLW-150E
4STW-200E
4SAH-200E
4SHH-250E
4SJH-300E
4SAH-2000
4SHH-2500
4SJH-3000
4SLW-1500
4STW-2000
4SAH-200E
4SHH-250E
4SJH-300E
4SLW-150E
4STW-200E
4SAH-200E
4SHH-250E
4SJH-300E
R22 (460V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R22 (230V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Delta Connection
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (230V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Delta Connection
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R407C (230V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Delta Connection
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R407C (460V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (460V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
72
6S Series
Motor Current Data (A)
-45
18.1
23.1
27.3
20.1
25.1
29.7
22.8
29.1
34.4
25.4
31.6
37.4
-40
20.6
25.6
29.7
22.4
27.9
33.6
25.9
32.2
37.4
28.2
35.2
42.4
-35
23.1
28.3
32.6
25.1
31.1
37.7
29.1
35.6
41.0
31.6
39.1
47.5
-30
25.6
31.2
35.9
33.5
35.3
44.1
28.1
34.5
41.9
32.3
39.3
45.3
42.2
44.5
55.6
35.4
43.5
52.8
-25
32.0
37.2
47.5
28.2
34.2
39.6
35.9
38.7
48.7
31.3
38.1
46.2
29.6
33.3
45.3
40.3
46.9
59.8
35.5
43.1
49.9
45.2
48.7
61.3
39.5
48.0
58.3
37.3
41.9
57.1
-20
34.6
40.1
50.7
30.7
37.5
43.5
38.5
42.2
52.9
34.7
41.9
50.7
32.5
36.8
48.5
43.5
50.5
63.9
38.7
47.2
54.8
48.5
53.2
66.7
43.7
52.8
63.9
41.0
46.4
61.1
-15
37.1
43.0
53.8
33.3
40.9
47.4
41.1
45.9
56.9
38.2
45.8
55.3
35.2
40.0
51.7
46.7
54.2
67.8
41.9
51.6
59.8
51.8
57.9
71.7
48.1
57.7
69.7
44.3
50.5
65.1
-10
39.5
45.7
56.7
35.9
44.6
51.4
43.8
49.6
60.6
41.6
49.7
60.0
37.6
43.0
54.8
49.7
57.6
71.5
45.2
56.2
64.7
55.1
62.5
76.4
52.4
62.6
75.7
47.4
54.2
69.0
-5
41.6
48.3
59.4
38.5
48.4
55.1
46.3
53.1
64.1
44.9
53.5
64.9
39.8
45.6
57.7
52.5
60.8
74.8
48.5
61.0
69.5
58.3
66.8
80.7
56.5
67.4
81.8
50.2
57.5
72.7
0
43.5
50.5
61.7
48.6
56.2
67.2
41.8
48.0
60.4
54.9
63.6
77.7
61.2
70.9
84.7
52.6
60.4
76.1
5
45.1
52.3
63.6
50.7
59.0
70.0
43.5
50.0
62.7
56.8
65.9
80.1
63.9
74.4
88.3
54.8
63.0
79.0
7
45.6
52.9
64.3
51.4
60.0
71.1
44.2
50.7
63.5
57.4
66.6
81.0
64.8
75.6
89.6
55.6
63.9
80.0
15
46.3
53.2
65.8
58.3
67.0
83.0
12.5
46.5
54.0
65.6
45.7
52.5
65.3
58.6
68.1
82.6
57.6
66.1
82.2
10
46.2
53.6
65.1
45.0
51.7
64.5
58.2
67.5
82.0
56.7
65.2
81.3
6SHH-3500
6SJH-4000
6SKH-5000
6SLW-2500
6STW-3200
6SUW-4000
6SHH-350E
6SJH-400E
6SKH-500E
6SLW-250E
6STW-320E
6SUW-400E
6SHH-350E
6SJH-400E
6SKH-500E
6SHH-3500
6SJH-4000
6SKH-5000
6SLW-2500
6STW-3200
6SUW-4000
6SHH-350E
6SJH-400E
6SKH-500E
6SLW-250E
6STW-320E
6SUW-400E
6SHH-350E
6SJH-400E
6SKH-500E
R22 (400V-3-50Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R407C (400V-3-50Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R22 (380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R407C (380V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Star Connection (Y)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (400V-3-50Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
73
6S Series
Motor Current Data (A)
-45
18.1
23.1
27.3
20.1
25.1
32.2
38.0
48.5
57.3
42.3
52.7
67.7
-40
20.6
25.6
29.7
22.4
27.9
36.0
43.2
53.7
62.3
47.1
58.6
75.7
-35
23.1
28.3
32.6
25.1
31.1
40.0
48.5
59.4
68.4
52.7
65.2
83.9
-30
25.6
31.2
35.9
33.5
35.3
44.1
28.1
34.5
44.0
53.8
65.5
75.4
70.3
74.1
92.7
59.0
72.4
92.3
-25
32.0
37.2
47.5
28.2
34.2
39.6
35.9
38.7
48.7
31.3
38.1
48.0
67.1
78.2
99.7
59.1
71.9
83.1
75.4
81.2
102.2
65.8
80.1
100.9
62.2
69.9
95.1
-20
34.6
40.1
50.7
30.7
37.5
43.5
38.5
42.2
52.9
34.7
41.9
52.2
72.6
84.2
106.5
64.5
78.7
91.3
80.8
88.7
111.2
72.9
88.0
109.6
68.3
77.3
101.8
-15
37.1
43.0
53.8
33.3
40.9
47.4
41.1
45.9
56.9
38.2
45.8
56.5
77.9
90.3
113.0
69.9
86.0
99.6
86.4
96.4
119.6
80.1
96.2
118.6
73.9
84.1
108.5
-10
39.5
45.7
56.7
35.9
44.6
51.4
43.8
49.6
60.6
41.6
49.7
60.8
82.9
96.1
119.1
75.3
93.6
107.9
91.9
104.1
127.3
87.3
104.3
127.8
79.0
90.3
115.1
-5
41.6
48.3
59.4
38.5
48.4
55.1
46.3
53.1
64.1
44.9
53.5
65.3
87.4
101.4
124.7
80.8
101.6
115.8
97.2
111.4
134.5
94.2
112.4
137.1
83.6
95.8
121.2
0
43.5
50.5
61.7
48.6
56.2
67.2
91.4
106.1
129.5
102.1
118.1
141.1
87.7
100.7
126.8
5
45.1
52.3
63.6
50.7
59.0
70.0
94.7
109.8
133.6
106.4
123.9
147.1
91.4
105.0
131.6
7
45.6
52.9
64.3
51.4
60.0
71.1
95.7
111.1
134.9
108.0
126.0
149.3
92.7
106.5
133.3
15
97.2
111.6
138.3
12.5
46.5
54.0
65.6
97.7
113.4
137.7
96.0
110.2
137.1
10
46.2
53.6
65.1
96.9
112.5
136.6
94.5
108.6
135.5
6SHH-3500
6SJH-4000
6SKH-5000
6SLW-2500
6STW-3200
6SUW-4000
6SHH-350E
6SJH-400E
6SKH-500E
6SLW-250E
6STW-320E
6SUW-400E
6SHH-3500
6SJH-4000
6SKH-5000
6SLW-2500
6STW-3200
6SUW-4000
6SHH-350E
6SJH-400E
6SKH-500E
6SLW-250E
6STW-320E
6SUW-400E
6SHH-350E
6SJH-400E
6SKH-500E
R22 (460V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R22 (230V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Delta Connection
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (230V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Delta Connection
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R407C (230V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Delta Connection
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 1512.510
R404A/507 (460V-3-60Hz) tc =40°C(CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
74
6T Series
Model Nomenclature & Bill of Materials
X X X X - X X X X - X X X - X X X
Oil Type Code Description 0 Mineral oil E Ester oil
Bill of Materials
Compressor Motor ProtectionCode Type W Motor protection with thermistors and module in the terminal box
Compressor Series Code Description 6 6 Cylinder
Design SeriesCode Description T Two stage
Displacement& Valve Plate
Model VariationW LT/UT
Motor Rating Power Code HP 1500 15 2000 20 2500 25 3000 30
Compressor Motor TypeCode Phase Motor Type A Three Part winding start E Three Dual voltage
Electrical Code Code Voltage PH Hz M 380-420PW 3 50 D 440-480PW 3 60 K 220-240∆ 3 60 380-420Y 3 60
6T Series Mounting Parts Rotalalock/Service valve Crankcase heater Electronic Oil Pressure Switch (OPS2) Motor Protection Module Subcooler Assembly
Bill of Materials (BOM)
000√√√
√
√√
030√√√
√
√
75
6T Series
50 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (with subcooler)Q=Capacity (kW) P=Power input (kW)
2530354045505525303540455055253035404550552530354045505525303540455055253035404550552530354045505525303540455055
Model
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
-45
9.909.609.409.309.209.109.106.506.907.207.608.008.308.5012.3012.0011.8011.6011.4011.4011.408.208.709.209.6010.1010.5010.8014.3014.0013.7013.4013.3013.2013.209.309.9010.4011.0011.4011.9012.3017.7017.3017.0016.7016.5016.4016.4011.7012.5013.2013.8014.5015.0015.50
-40
12.5012.3012.1012.0011.9011.8011.807.307.808.308.709.209.609.90
15.6015.4015.2015.0014.8014.8014.709.309.90
10.5011.0011.6012.1012.6018.1017.8017.6017.4017.2017.1017.1010.5011.2011.9012.6013.2013.8014.3022.5022.1021.8021.6021.4021.3021.2013.3014.2015.0015.9016.6017.4018.00
-35
15.5015.3015.2015.0014.9014.8014.808.208.809.309.80
10.4010.9011.3019.4019.2018.9018.8018.6018.5018.4010.4011.1011.8012.5013.1013.7014.3022.5022.2022.0021.8021.6021.5021.4011.8012.6013.4014.2014.9015.6016.3028.0027.6027.3027.0026.8026.6026.5014.9015.9016.9017.9018.8019.7020.60
-30
19.0018.8018.6018.4018.2018.1018.009.109.70
10.3010.9011.6012.2012.7023.7023.5023.2023.0022.8022.6022.5011.5012.3013.1013.9014.6015.4016.1027.5027.2026.9026.7026.4026.3026.1013.0013.9014.8015.7016.6017.5018.3034.2033.8033.4033.1032.8032.6032.4016.4017.6018.7019.9021.0022.1023.10
Evaporating Temperature oCCondensingTemperature
oC -25
22.9022.7022.5022.2022.0021.8021.709.90
10.6011.3012.0012.8013.5014.1028.7028.4028.1027.8027.5027.3027.1012.5013.4014.3015.2016.1017.0017.9033.2032.9032.6032.2031.9031.6031.4014.2015.3016.3017.3018.3019.4020.3041.3040.8040.4040.0039.6039.3039.0018.0019.3020.6021.9023.2024.4025.70
-20
27.4027.1026.9026.6026.3026.0025.8010.7011.5012.3013.1013.9014.7015.5034.3033.9033.6033.2032.8032.5032.2013.6014.6015.6016.6017.6018.6019.6039.8039.4038.9038.5038.1037.7037.4015.4016.6017.7018.9020.0021.2022.3049.4048.9048.3047.8047.3046.8046.4019.5020.9022.4023.8025.3026.8028.20
-50
7.507.207.006.806.70
5.605.906.206.506.80
9.409.008.708.508.30
7.107.507.908.208.60
10.9010.5010.109.909.70
8.008.509.009.409.70
13.5013.0012.6012.2012.00
10.1010.7011.3011.8012.30
Notes:Suction Gas Temperature 20°CLiquid subcooling 8.3K
76
6T Series
50 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (without subcooler)Q=Capacity (kW) P=Power input (kW)
2530354045505525303540455055253035404550552530354045505525303540455055253035404550552530354045505525303540455055
Model
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
-45
8.508.107.707.407.006.706.306.606.907.207.507.808.108.5010.8010.309.809.308.808.407.908.308.709.009.309.7010.1010.5012.0011.3010.7010.109.509.008.409.209.509.9010.2010.6010.9011.3014.3013.6012.9012.3011.7011.1010.5010.7011.3011.9012.4012.9013.5014.30
-40
11.0010.6010.109.609.108.608.207.307.708.008.408.709.109.50
14.0013.4012.8012.1011.5010.9010.409.309.80
10.2010.6011.1011.5012.0015.7014.9014.2013.4012.7012.0011.3010.6011.0011.5011.9012.3012.8013.3018.6017.8017.1016.3015.6014.9014.2012.2013.0013.8014.5015.3016.1017.00
-35
14.1013.4012.8012.2011.6011.0010.508.008.408.909.309.80
10.3010.7017.9017.1016.3015.5014.7014.0013.2010.4010.9011.5012.0012.5013.1013.6020.2019.3018.3017.4016.5015.6014.7012.0012.5013.1013.7014.2014.8015.4023.8022.8021.9021.0020.1019.2018.3013.6014.6015.6016.5017.5018.5019.60
-30
17.7016.9016.1015.4014.6013.9013.208.609.209.70
10.3010.8011.4012.0022.4021.5020.5019.5018.6017.6016.7011.5012.1012.8013.4014.1014.7015.4025.5024.4023.3022.2021.0019.9018.9013.4014.2014.9015.6016.3017.0017.7029.8028.7027.5026.4025.3024.1023.0014.8016.0017.2018.3019.4020.6021.90
Evaporating Temperature oCCondensingTemperature
oC -25
21.9021.0020.0019.1018.2017.3016.309.309.90
10.6011.3011.9012.6013.3027.9026.7025.5024.3023.1021.9020.7012.6013.4014.2014.9015.7016.5017.3031.9030.5029.2027.8026.4025.0023.7015.0015.8016.7017.6018.4019.3020.1036.9035.5034.1032.7031.3029.9028.4015.8017.2018.6019.9021.2022.6024.00
-20
26.9025.8024.6023.5022.3021.2020.009.90
10.7011.5012.3013.1013.9014.7034.3032.8031.4029.9028.4026.9025.5013.6014.6015.5016.5017.4018.4019.3039.4037.8036.1034.4032.8031.1029.4016.5017.5018.6019.6020.6021.7022.7045.3043.6041.9040.1038.4036.6034.8016.6018.2019.8021.3022.7024.3025.90
-50
6.506.205.905.605.30
6.006.206.406.706.90
8.207.807.407.006.60
7.407.607.908.208.40
8.908.407.907.406.90
7.908.208.408.708.90
10.509.909.308.708.20
9.109.509.8010.1010.40
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
77
6T Series
50 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (with subcooler)Q=Capacity (kW) P=Power input (kW)
303540455055303540455055303540455055303540455055303540455055303540455055303540455055303540455055
Model
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
-55
8.308.007.807.607.407.306.707.007.407.808.208.5010.3010.009.609.409.209.008.709.209.7010.2010.7011.1012.1011.7011.3011.0010.8010.609.9010.5011.0011.6012.2012.7014.4013.9013.5013.1012.8012.6012.0012.6013.3014.0014.7015.30
-50
10.5010.209.909.709.509.307.608.008.408.909.309.70
13.0012.7012.3012.0011.7011.509.90
10.4011.0011.6012.1012.7015.3014.9014.5014.1013.8013.5011.3011.9012.6013.2013.9014.5018.2017.7017.2016.7016.4016.1013.6014.4015.1015.9016.7017.50
-45
13.1012.8012.4012.1011.9011.608.509.009.50
10.0010.5011.0016.2015.8015.4015.0014.7014.4011.1011.7012.3013.0013.7014.3019.0018.6018.1017.6017.2016.9012.6013.3014.1014.8015.6016.3022.6022.1021.5021.0020.5020.1015.2016.1017.0017.9018.8019.70
-40
16.1015.7015.3014.9014.6014.309.40
10.0010.5011.1011.7012.3019.9019.4019.0018.5018.1017.7012.3013.0013.8014.5015.2016.0023.4022.8022.3021.7021.2020.8014.0014.9015.7016.5017.4018.3027.8027.1026.5025.8025.2024.7016.9017.9018.9020.0021.0022.00
Evaporating Temperature oCCondensingTemperature
oC -35
19.4019.0018.6018.1017.7017.3010.4011.0011.7012.3013.0013.6024.1023.5023.0022.5021.9021.5013.6014.4015.3016.1016.9017.8028.3027.6027.0026.4025.8025.2015.5016.5017.4018.4019.3020.3033.6032.9032.1031.4030.6030.0018.8019.9021.0022.2023.3024.50
-20
32.4031.7031.0030.3029.60
14.1015.0015.8016.7017.70
40.1039.3038.4037.5036.70
18.5019.6020.7021.9023.10
47.0046.1045.1044.1043.00
21.1022.3023.6024.9026.30
55.9054.8053.6052.4051.20
25.4026.9028.5030.1031.70
-25
27.6027.0026.4025.8025.2024.6012.8013.5014.3015.1015.9016.8034.1033.4032.7031.9031.2030.5016.7017.7018.7019.7020.8021.9040.1039.2038.4037.5036.6035.8019.0020.2021.3022.5023.8025.0047.6046.7045.6044.6043.5042.5023.0024.3025.7027.2028.7030.20
-30
23.3022.8022.3021.8021.2020.8011.5012.2012.9013.7014.4015.1028.8028.2027.6026.9026.3025.7015.1016.0016.9017.8018.8019.8033.8033.1032.4031.6030.9030.2017.2018.2019.3020.3021.4022.6040.2039.4038.5037.6036.7035.9020.8022.0023.3024.6025.9027.20
-60
6.406.205.905.805.605.605.706.106.406.707.007.307.907.607.407.107.006.907.507.908.408.809.209.609.309.008.608.408.208.108.509.009.5010.0010.5010.9011.1010.7010.309.909.709.6010.3010.9011.5012.1012.7013.20
Notes:Suction Gas Temperature 20°CLiquid subcooling 8.3K
R404A /507R404A /507
78
6T Series
50 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (without subcooler)Q=Capacity (kW) P=Power input (kW)
303540455055303540455055303540455055303540455055303540455055303540455055303540455055303540455055
Model
6TAW-150E
6THW-200E
6TJW-2500
6TKW-300E
-55
4.604.304.003.703.403.006.106.306.506.706.907.205.805.405.104.704.303.907.608.008.208.308.508.806.906.406.005.505.104.608.508.809.009.309.509.809.909.308.708.107.506.9010.1010.6011.0011.5011.9012.50
-50
6.305.905.505.104.604.207.007.207.407.708.008.207.907.306.906.405.905.308.709.209.509.709.90
10.309.208.608.007.406.806.309.70
10.0010.3010.7011.0011.3013.1012.3011.5010.609.809.00
11.6012.1012.7013.3013.9014.50
-45
8.407.807.306.806.205.507.908.108.408.709.109.40
10.409.709.008.407.707.00
10.0010.5010.9011.1011.5012.0012.2011.4010.709.909.108.40
11.1011.5011.9012.3012.6013.0016.9015.9014.8013.8012.7011.6013.3014.0014.6015.3016.1016.80
-40
11.0010.309.508.808.107.208.809.109.509.80
10.3010.6013.5012.6011.7010.9010.009.00
11.2011.9012.3012.7013.1013.7015.8014.8013.8012.8011.9010.9012.6013.1013.6014.1014.6015.0021.5020.2018.9017.5016.1014.7015.3016.0016.8017.6018.4019.20
Evaporating Temperature oCCondensingTemperature
oC -35
14.0013.1012.2011.3010.409.309.70
10.2010.6011.0011.5011.9017.2016.0014.9013.8012.6011.5012.5013.2013.8014.2014.8015.5020.1018.8017.6016.3015.1013.9014.2014.9015.5016.1016.7017.3026.8025.2023.6021.9020.2018.4017.5018.3019.2020.0020.9021.80
-20
26.6024.9023.3021.5019.7017.8012.6013.3014.0014.7015.5016.2031.9029.7027.6025.4023.3021.2016.0017.2018.2019.1020.1021.3036.8034.5032.2030.0027.8025.5019.5020.6021.8023.0024.1025.2048.4045.7042.9040.1037.1034.1025.3026.3027.2028.1029.1030.00
-25
21.8020.4019.1017.7016.2014.5011.6012.2012.8013.5014.1014.7026.3024.5022.8021.0019.3017.5014.9015.9016.7017.5018.3019.3030.6028.7026.8024.9023.1021.2017.7018.7019.6020.6021.5022.4040.2037.9035.6033.1030.6028.0022.5023.5024.4025.3026.3027.20
-30
17.6016.5015.4014.3013.0011.7010.7011.2011.7012.2012.8013.3021.4020.0018.6017.2015.7014.3013.7014.6015.2015.9016.5017.4025.0023.4021.9020.3018.9017.4015.9016.7017.5018.3019.0019.8033.0031.1029.1027.1025.0022.8019.9020.8021.7022.6023.5024.50
-60
3.303.002.802.602.402.105.305.405.605.806.006.204.304.003.703.403.102.806.406.806.907.007.207.505.204.804.504.103.803.407.507.708.008.208.408.707.306.806.305.905.605.209.009.309.609.9010.2010.60
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
R404A /507R404A /507
79
6T Series
60 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (with subcooler)Q=Capacity (kW) P=Power input (kW)
2530354045505525303540455055253035404550552530354045505525303540455055253035404550552530354045505525303540455055
Model
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
-45
11.6011.3011.1010.9010.8010.7010.707.708.208.709.109.509.9010.2014.6014.2013.9013.7013.6013.5013.409.8010.4011.0011.6012.1012.5012.9016.9016.5016.1015.9015.7015.6015.6011.2011.9012.5013.2013.8014.3014.7020.2019.8019.4019.1018.8018.7018.7013.7014.5015.3016.1016.8017.5018.00
-40
14.7014.5014.3014.1014.0013.9013.908.809.409.90
10.5011.0011.5011.9018.5018.2017.9017.7017.6017.5017.4011.1011.8012.6013.2013.9014.5015.1021.4021.1020.8020.5020.3020.2020.2012.7013.5014.3015.1015.8016.5017.2025.7025.3024.9024.6024.4024.3024.2015.5016.5017.5018.5019.4020.2021.00
-35
18.3018.1017.9017.7017.5017.4017.409.80
10.5011.1011.8012.4013.0013.6023.0022.7022.4022.2022.0021.9021.8012.4013.3014.1014.9015.7016.5017.2026.6026.2025.9025.7025.5025.3025.2014.2015.1016.1017.0017.9018.8019.6031.9031.5031.2030.8030.6030.4030.3017.3018.5019.7020.8021.9023.0024.00
-30
22.4022.1021.9021.7021.5021.3021.2010.8011.6012.4013.1013.9014.6015.3028.1027.8027.5027.2027.0026.8026.7013.7014.7015.7016.6017.5018.5019.3032.5032.1031.8031.5031.2031.0030.8015.6016.7017.8018.9020.0021.0022.0039.0038.6038.2037.8037.5037.2037.0019.2020.5021.8023.2024.5025.7026.90
Evaporating Temperature oCCondensingTemperature
oC -25
27.0026.7026.5026.2025.9025.7025.5011.9012.7013.6014.4015.3016.1016.9033.9033.6033.2032.9032.6032.3032.1015.0016.1017.2018.3019.4020.4021.4039.2038.8038.4038.0037.7037.4037.1017.1018.3019.6020.8022.0023.2024.4047.1046.6046.1045.7045.3044.9044.5020.9022.4024.0025.5027.0028.5029.90
-20
32.3032.0031.6031.3031.0030.7030.4012.8013.8014.8015.7016.7017.7018.6040.6040.2039.7039.3038.9038.5038.1016.3017.5018.7019.9021.2022.4023.6047.0046.5046.0045.5045.0044.5044.1018.5019.9021.3022.7024.1025.5026.8056.4055.8055.2054.6054.0053.5053.0022.7024.4026.1027.8029.5031.2032.80
-50
8.808.508.208.007.90
6.707.107.507.808.10
11.1010.7010.3010.109.90
8.509.009.509.9010.30
12.8012.4012.0011.6011.40
9.6010.2010.8011.3011.70
15.4014.8014.4014.0013.70
11.8012.5013.2013.8014.30
Notes:Suction Gas Temperature 20°CLiquid subcooling 8.3K
80
6T Series
60 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (without subcooler)Q=Capacity (kW) P=Power input (kW)
2530354045505525303540455055253035404550552530354045505525303540455055253035404550552530354045505525303540455055
Model
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
-45
10.109.609.108.708.307.907.508.008.308.609.009.409.7010.2012.8012.2011.6011.0010.509.909.4010.0010.4010.8011.2011.7012.1012.6014.1013.4012.7012.0011.3010.609.9011.1011.5011.9012.3012.7013.1013.6014.3013.6012.9012.3011.7011.1010.5010.7011.3011.9012.4012.9013.5014.30
-40
13.0012.5011.9011.3010.8010.209.708.809.209.60
10.1010.5011.0011.5016.5015.8015.0014.3013.6012.9012.2011.2011.7012.3012.8013.3013.8014.4018.5017.6016.7015.8015.0014.1013.3012.7013.2013.7014.3014.8015.4015.9018.6017.8017.1016.3015.6014.9014.2012.2013.0013.8014.5015.3016.1017.00
-35
16.6015.9015.1014.4013.7013.0012.409.60
10.1010.7011.2011.7012.3012.9021.0020.1019.2018.3017.4016.5015.6012.5013.1013.8014.4015.0015.7016.3023.8022.7021.6020.5019.5018.4017.4014.4015.1015.7016.4017.1017.8018.5023.8022.8021.9021.0020.1019.2018.3013.6014.6015.6016.5017.5018.5019.60
-30
20.8019.9019.0018.2017.3016.4015.5010.4011.0011.7012.3013.0013.7014.4026.5025.3024.2023.0021.9020.7019.6013.8014.6015.3016.1016.9017.7018.5030.1028.8027.5026.1024.8023.5022.2016.1017.0017.8018.7019.5020.3021.2029.8028.7027.5026.4025.3024.1023.0014.8016.0017.2018.3019.4020.6021.90
Evaporating Temperature oCCondensingTemperature
oC -25
25.8024.7023.6022.5021.4020.3019.3011.2012.0012.7013.5014.3015.1015.9032.9031.5030.1028.7027.2025.8024.4015.1016.0017.0017.9018.9019.8020.7037.7036.0034.4032.8031.2029.6028.0017.9019.0020.0021.0022.1023.1024.1036.9035.5034.1032.7031.3029.9028.4015.8017.2018.6019.9021.2022.6024.00
-20
31.8030.4029.1027.7026.4025.0023.6011.9012.8013.8014.7015.7016.6017.6040.5038.8037.0035.3033.5031.8030.0016.4017.5018.6019.8020.9022.0023.1046.5044.6042.6040.6038.6036.7034.7019.8021.0022.3023.5024.8026.0027.3045.3043.6041.9040.1038.4036.6034.8016.6018.2019.8021.3022.7024.3025.90
-50
7.607.306.906.606.30
7.207.507.708.008.30
9.709.208.708.307.80
8.909.209.509.8010.20
10.509.909.308.708.20
9.509.8010.2010.5010.80
10.509.909.308.708.20
9.109.509.8010.1010.40
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
81
6T Series
60 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (with subcooler)Q=Capacity (kW) P=Power input (kW)
303540455055303540455055303540455055303540455055303540455055303540455055303540455055303540455055
Model
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
-55
9.809.509.208.908.708.608.008.408.909.309.8010.2012.1011.7011.4011.0010.8010.6010.4011.0011.6012.2012.8013.4014.3013.8013.4013.0012.7012.5011.9012.6013.2013.9014.6015.2016.5016.0015.5015.1014.7014.5013.8014.6015.4016.2017.0017.70
-50
12.4012.1011.7011.4011.2011.009.009.60
10.1010.6011.1011.6015.4014.9014.5014.1013.8013.6011.8012.5013.2013.9014.6015.2018.1017.6017.1016.7016.3016.0013.5014.3015.0015.8016.6017.4021.0020.4019.8019.3018.9018.5015.7016.6017.5018.4019.3020.20
-45
15.5015.1014.7014.3014.0013.7010.1010.7011.3011.9012.5013.1019.1018.6018.2017.7017.3017.0013.3014.0014.8015.6016.4017.2022.5022.0021.4020.9020.4020.0015.1016.0016.9017.8018.7019.6026.1025.4024.8024.2023.6023.2017.6018.6019.7020.7021.8022.80
-40
19.0018.5018.1017.7017.3016.9011.3011.9012.6013.3014.0014.7023.4022.9022.3021.8021.3020.9014.7015.6016.5017.4018.3019.2027.6027.0026.3025.7025.1024.6016.8017.8018.8019.8020.8021.9032.0031.3030.5029.8029.1028.5019.6020.7021.9023.1024.3025.50
Evaporating Temperature oCCondensingTemperature
oC -35
23.0022.5021.9021.4020.9020.5012.5013.2014.0014.8015.5016.3028.4027.7027.1026.5025.8025.3016.3017.3018.3019.3020.3021.3033.4032.7031.9031.2030.5029.8018.6019.7020.8022.0023.2024.3038.7037.9037.0036.1035.3034.5021.7023.0024.3025.6027.0028.40
-20
38.2037.5036.6035.8035.00
16.9017.9019.0020.0021.10
47.2046.3045.3044.2043.20
22.1023.4024.8026.2027.60
55.6054.5053.4052.1050.90
25.2026.7028.3029.9031.50
64.4063.2061.8060.4059.00
29.4031.2033.0034.8036.70
-25
32.6031.9031.2030.5029.8029.1015.3016.2017.1018.1019.1020.1040.2039.4038.5037.6036.8035.9020.0021.2022.4023.7025.0026.3047.4046.4045.4044.4043.3042.3022.8024.1025.5027.0028.4029.9054.9053.8052.6051.4050.2049.0026.6028.1029.8031.5033.2034.90
-30
27.5026.9026.3025.7025.1024.5013.8014.6015.5016.3017.2018.1033.9033.2032.5031.7031.0030.3018.1019.1020.2021.4022.5023.7040.0039.2038.3037.4036.5035.7020.6021.8023.1024.4025.7027.0046.3045.4044.3043.3042.3041.3024.0025.4026.9028.4029.9031.50
-60
7.607.307.006.806.606.606.907.307.708.108.408.809.409.008.708.408.208.109.009.5010.0010.5011.0011.5011.0010.6010.209.909.709.6010.2010.8011.4012.0012.6013.1012.8012.3011.8011.4011.2011.1011.9012.6013.3014.0014.7015.30
Notes:Suction Gas Temperature 20°CLiquid subcooling 8.3K
R404A /507R404A /507
82
6T Series
60 Hz
Q
P
Q
P
Q
P
Q
P
Performance Data (without subcooler)Q=Capacity (kW) P=Power input (kW)
303540455055303540455055303540455055303540455055303540455055303540455055303540455055303540455055
Model
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
-55
5.405.004.704.404.003.607.307.507.808.008.308.606.906.406.005.605.104.609.109.609.8010.0010.2010.608.107.607.106.506.005.4010.2010.5010.9011.2011.5011.8011.3010.609.909.208.507.9011.8012.3012.8013.3013.9014.50
-50
7.406.906.406.005.504.908.408.608.909.209.509.909.308.708.107.506.906.20
10.5011.1011.4011.6011.9012.4010.9010.209.508.808.107.40
11.6012.0012.4012.8013.2013.5015.0014.0013.1012.2011.2010.3013.5014.1014.8015.5016.2016.90
-45
9.909.208.608.007.306.509.509.80
10.1010.5010.9011.3012.3011.5010.709.909.108.20
12.0012.6013.0013.4013.7014.3014.4013.5012.6011.7010.809.90
13.3013.8014.2014.7015.2015.6019.3018.2017.0015.7014.5013.3015.5016.2017.0017.9018.7019.60
-40
12.9012.1011.3010.409.508.50
10.6011.0011.4011.8012.3012.8015.9014.9013.8012.8011.8010.7013.5014.2014.8015.2015.7016.4018.7017.5016.3015.2014.0012.9015.1015.7016.3016.9017.5018.0024.5023.1021.5020.0018.4016.8017.8018.7019.6020.5021.4022.40
Evaporating Temperature oCCondensingTemperature
oC -35
16.5015.5014.4013.4012.2011.0011.7012.2012.7013.2013.8014.3020.2018.9017.6016.2014.9013.5014.9015.8016.5017.1017.7018.6023.7022.2020.7019.3017.8016.4017.1017.8018.6019.3020.0020.7030.6028.8027.0025.0023.1021.0020.4021.3022.3023.3024.3025.40
-20
31.4029.4027.5025.4023.3021.0015.1015.9016.8017.7018.6019.4037.6035.0032.5030.0027.5025.0019.2020.6021.8022.9024.1025.5043.5040.7038.0035.4032.7030.1023.4024.8026.2027.6028.9030.3055.2052.2049.0045.7042.4038.9029.5030.6031.6032.7033.8035.00
-25
25.7024.1022.5020.8019.1017.2014.0014.7015.4016.2016.9017.7031.1028.9026.9024.8022.8020.7017.9019.1020.1021.0021.9023.2036.1033.8031.6029.4027.2025.1021.2022.4023.5024.7025.8026.9045.9043.3040.6037.8034.9032.0026.2027.3028.4029.5030.6031.70
-30
20.8019.5018.2016.8015.4013.8012.8013.4014.0014.7015.3016.0025.3023.5021.9020.2018.6016.9016.4017.5018.3019.0019.8020.8029.5027.6025.8024.0022.2020.5019.1020.0021.0021.9022.8023.7037.7035.5033.3030.9028.5026.1023.2024.2025.3026.3027.4028.50
-60
3.903.603.303.102.802.506.306.506.706.907.207.505.004.704.404.103.703.307.708.108.308.408.609.006.105.705.304.904.404.009.009.309.609.9010.2010.408.307.807.206.806.306.0010.5010.8011.2011.5011.9012.30
Notes:Suction Gas Temperature 20°CLiquid subcooling 0K
R404A /507R404A /507
83
6T Series
Dimensional Drawing
L6L7
H H3
L8 381
H2
LL1 133
L2H
1
305355
1
2DL
3
8, 9
7
6
4
5
10
11
L’
L9L10
19
12
H4
131415
16
17
18
293
L3’
L8’
L3
L4 381 L5
6TAW-1500/E, 6THW-2000/E, 6TJW-2500/E, 6TKW-3000/E
SL Ø(Suction
Line)
1 5/8"
1 5/8"
1 5/8"
1 5/8"
DL Ø(Discharge
Line)
1 3/8"
1 3/8"
1 3/8"
1 3/8"
A(Mounting
Length)
381mm
381mm
381mm
381mm
B(Mounting
Length)
305mm
305mm
305mm
305mm
L(Length)
903 mm
903 mm
903 mm
962 mm
W(Width)
602 mm
602 mm
602 mm
612 mm
H(Height)
569 mm
569 mm
619 mm
619 mm
L(Length)
756 mm
756 mm
756 mm
815 mm
W(Width)
547 mm
547 mm
547 mm
596 mm
H(Height)
569 mm
569 mm
619 mm
619 mm
MODEL
6TAW-1500/E
6THW-2000/E
6TJW-2500/E
6TKW-3000/E
with subcooler without subcooler
84
6T Series
Dimensional Drawing
with subcooler without subcooler
6TAW-1500(E)6THW-2000(E)
6TJW-2500(E)6TKW-3000(E)
6TAW-1500(E)6THW-2000(E)
6TJW-2500(E)6TKW-3000(E)
√
√
√
√
√
√
√
√
√
√
√
x
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
x
x
x
x
x
x
x
x
√
√
√
√
√
√
√
√
√
√
√
√
x
x
x
x
x
x
x
LIST OF MATERIAL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Plug – low pressure connection
Plug – high pressure connection
Plug – oil charge
Oil-pressure control H. P.
Oil-pressure connection
Plug oil-pressure control L. P.
Oil Pressure Switch sensor connection
Oil screen built in
Magnetic plug
Plug - crankcase heater
Bore crankcase heater
Intermediate pressure connection
Liquid line from receiver (sweat)
Sub-cooler
Filter
Solenoid valve
Liquid line to evaporator (sweat)
De-superheating expansion valve
Tube subcool intermediate
¼” – 18NPTF
1/8” - 27NPTF
¼” – 18NPTF
1/4”≈6mm
7/16”-20UNF
1/4”-18NPTF
N/A
N/A
1”-16UN
1/2”-14NPTF
Ø1/2” = 12.7mm
7/16”-20UNF
Ø7/8” = 22mm
N/A
N/A
N/A
Ø7/8” = 22mm
N/A
Ø5/8” = 15.875mm
ITEM DESCRIPTION SPECIFICATIONS
85
Wiring Diagram
Electrical diagram for direct start
Electrical diagram For Part winding Start (AWM/D model)
6T Series
Control Circuit 220-240V 50/60Hz
Control Circuit 220-240V 50/60Hz
86
Wiring Diagram
Electrical diagram For Y-∆ Start (EWK Model)
6T Series
Electrical Diagram Coding
A1: Motor protector module
A2: Oil Differential Pressure Switch OPS2
D1: Operating recognition Connection;
E: Grounding Connection
E1: Crankcase Heater
E2-E3: Thermal protection switch for fan
K11: Time delay relay 1-3s for Y/Δstart
K12: Time delay relay 1s±0.1s for Part-winding Start
K1-K4: contactor M1
K5,K55: Fan contactor
K6: Thermostat
M: Compressor motor
Q1: Mini-breaker
Q2: Mini-breaker
S1: Control Switch
Y1: H/L pressure switches
L1, L2, L3: Voltage Connection
380-420V-3-50 Hz -PW
380-420V-3-60Hz-Y
220-240V-3-60Hz-Delta
440-480V-3-60Hz-PW
Color code
VT: violet
OG: orange
GY: grey
BN: brown
BU: blue
PK: pink
Control Circuit 220-240V 50/60Hz
87
Terminal Jumper Schematics
6T Series
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
1(U) 2(V) 3(W)
7(Z) 8(X) 9(Y)
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
L1 L2 L3
L1 L2 L3
1(U)
7(Z)
2(V)
8(X)
3(W)
9(Y)
E.4.01.00 E.4.02.00
E.4.03.00
E.4.05.00E.4.01.00
Direct-On-Line Start Direct-On-Line StartY
Star-Delta-StartY-
Part-Winding Start, first Start Step 1-2-3Y-Y
Direct-On-Line StartY-Y
Star-Delta-MotorY-
Code E
Part-WindingMotor:
Y-YCode A
88
6T Series
Motor Current Data (A)
-60
14.0
17.5
20.0
26.6
16.7
20.7
24.1
29.9
-55
15.3
19.2
21.9
29.1
18.3
22.7
26.4
32.7
-50
14.4
17.4
20.1
27.4
16.7
20.9
23.9
31.8
17.2
21.1
24.2
31.0
20.0
24.8
28.8
35.7
-45
15.5
18.8
21.7
29.6
18.1
22.7
25.9
34.5
18.6
22.8
26.2
33.5
21.7
26.9
31.2
38.7
-40
16.9
20.4
23.6
32.2
19.5
24.5
27.9
37.1
20.2
24.8
28.5
36.4
23.3
28.9
33.6
41.7
-35
18.4
22.2
25.7
35.0
20.9
26.2
29.9
39.8
22.0
27.0
31.0
39.6
25.0
31.0
36.0
44.7
-30
19.9
24.1
27.9
37.9
22.2
27.9
31.8
42.3
23.9
29.3
33.6
42.9
26.6
33.0
38.3
47.6
-25
21.5
25.9
30.0
40.9
23.5
29.5
33.6
44.7
25.7
31.5
36.2
46.3
28.1
34.9
40.5
50.3
-20
22.9
27.7
32.1
43.6
24.7
31.0
35.4
47.0
27.4
33.7
38.7
49.4
29.6
36.7
42.6
52.8
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
R22 (400V-3-50Hz ) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
R404A/507 (400V-3-50Hz ) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R22 (380V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Star Connection (Y)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R404A/507 (380V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Star Connection (Y)
-60 -55 -50 -45 -40 -35 -30 -25 -20
With Subcooler
89
6T Series
Motor Current Data (A)
-60
14.0
17.5
20.0
26.6
29.2
36.2
42.1
52.3
-55
15.3
19.2
21.9
29.1
32.1
39.8
46.2
57.3
-50
14.4
17.4
20.1
27.4
16.7
20.9
23.9
31.8
30.1
36.9
42.4
54.2
35.0
43.4
50.4
62.5
-45
15.5
18.8
21.7
29.6
18.1
22.7
25.9
34.5
32.5
39.9
45.8
58.6
37.9
47.0
54.6
67.8
-40
16.9
20.4
23.6
32.2
19.5
24.5
27.9
37.1
35.4
43.4
49.9
63.7
40.9
50.7
58.8
73.0
-35
18.4
22.2
25.7
35.0
20.9
26.2
29.9
39.8
38.5
47.3
54.3
69.3
43.8
54.3
63.0
78.2
-30
19.9
24.1
27.9
37.9
22.2
27.9
31.8
42.3
41.7
51.2
58.8
75.1
46.6
57.7
67.0
83.2
-25
21.5
25.9
30.0
40.9
23.5
29.5
33.6
44.7
45.0
55.2
63.4
80.9
49.2
61.0
70.9
88.0
-20
22.9
27.7
32.1
43.6
24.7
31.0
35.4
47.0
48.0
58.9
67.7
86.4
51.7
64.1
74.5
92.5
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
R22 (460V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
R404A/507 (460V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R22 (230V-3-60Hz)
Evaporating temperature °CModel
Delta Connection (∆)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R404A/507 (230V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Delta Connection (∆)
-60 -55 -50 -45 -40 -35 -30 -25 -20
With Subcooler
90
6T Series
Motor Current Data (A)
-60
15.5
16.8
20.2
27.7
19.5
21.1
25.4
31.1
-55
16.4
18.1
21.4
29.9
20.6
22.8
26.9
33.6
-50
13.5
17.7
18.3
24.6
17.4
19.7
22.9
32.2
17.0
22.3
23.0
24.6
21.9
24.8
28.9
36.2
-45
14.6
19.1
20.1
27.6
18.5
21.4
24.8
34.6
18.3
24.1
25.3
27.6
23.3
26.9
31.3
38.9
-40
15.8
20.7
22.2
30.5
19.7
23.2
27.0
37.1
19.9
26.1
27.9
30.5
24.9
29.3
34.1
41.7
-35
17.1
22.5
24.5
33.3
21.1
25.2
29.5
39.6
21.5
28.4
30.9
33.3
26.5
31.8
37.2
44.5
-30
18.5
24.5
27.1
35.9
22.5
27.4
32.3
42.0
23.3
30.9
34.2
35.9
28.3
34.5
40.7
47.3
-25
20.0
26.6
30.0
38.3
24.0
29.7
35.4
44.5
25.2
33.6
37.7
38.3
30.3
37.4
44.6
50.0
-20
21.5
28.9
33.0
40.4
25.7
32.1
38.6
46.8
27.1
36.4
41.5
40.4
32.4
40.5
48.7
52.6
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
R22 (400V-3-50Hz ) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
R404A/507 (400V-3-50Hz ) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R22 (380V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Star Connection (Y)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R404A/507 (380V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Star Connection (Y)
-60 -55 -50 -45 -40 -35 -30 -25 -20
Without Subcooler
91
6T Series
Motor Current Data (A)
-60
15.5
16.8
20.2
31.1
34.1
37.0
44.5
54.4
-55
16.4
18.1
21.4
33.6
36.1
40.0
47.1
58.8
-50
13.5
17.7
18.3
24.6
17.4
19.7
22.9
36.2
29.7
39.1
40.3
43.0
38.3
43.4
50.5
63.4
-45
14.6
19.1
20.1
27.6
18.5
21.4
24.8
38.9
32.1
42.2
44.3
48.3
40.8
47.1
54.7
68.1
-40
15.8
20.7
22.2
30.5
19.7
23.2
27.0
41.7
34.7
45.7
48.9
53.4
43.5
51.2
59.6
73.0
-35
17.1
22.5
24.5
33.3
21.1
25.2
29.5
44.5
37.6
49.7
54.1
58.3
46.4
55.6
65.2
77.9
-30
18.5
24.5
27.1
35.9
22.5
27.4
32.3
47.3
40.7
54.0
59.8
62.9
49.6
60.4
71.3
82.8
-25
20.0
26.6
30.0
38.3
24.0
29.7
35.4
50.0
44.0
58.7
66.0
67.0
53.0
65.5
78.0
87.5
-20
21.5
28.9
33.0
40.4
25.7
32.1
38.6
52.6
47.4
63.7
72.7
70.8
56.6
70.8
85.2
92.1
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
6TAW-1500
6THW-2000
6TJW-2500
6TKW-3000
6TAW-150E
6THW-200E
6TJW-250E
6TKW-300E
R22 (460V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
R404A/507 (460V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Part Winding Connection (PW)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R22 (230V-3-60Hz)
Evaporating temperature °CModel
Delta Connection (∆)
-60 -55 -50 -45 -40 -35 -30 -25 -20
R404A/507 (230V-3-60Hz) tc = 40°C (CT)
Evaporating temperature °CModel
Delta Connection (∆)
-60 -55 -50 -45 -40 -35 -30 -25 -20
Without Subcooler
92
ALL Series
LSeries
Mechanical Data
LA10-0200LA10-020ELA20-0200LA20-020ELA20-0300LA20-030ELA40-0300LA40-030ELA40-0400LA40-040ELA50-0400LA50-040E 2SCW-05502SCW-055E2SKW-07502SKW-075E3SCH-10003SCH-100E3SSH-15003SSH-150E3SC1-10003SC1-100E3SS1-15003SS1-150E4SAH-20004SAH-200E4SHH-25004SHH-250E4SJH-30004SJH-300E4SLW-15004SLW-150E4STW-20004STW-200E6SHH-35006SHH-350E6SJH-40006SJH-400E6SKH-50006SKH-500E6SLW-25006SLW-250E6STW-32006STW-320E6SUW-40006SUW-400E6TAW-1500 SUB6TAW-150E SUB6THW-2000 SUB6THW-200E SUB6TJW-2500 SUB6TJW-250E SUB6TKW-3000 SUB6TKW-300E SUB6TAW-15006TAW-150E6THW-20006THW-200E6TJW-25006TJW-250E6TKW-30006TKW-300E
Model
DLE-201DLE-20XDLF-201DLF-20XDLF-301DLF-30XDLL-301DLL-30XDLL-401DLL-40X
DLSG-401DLSG-40XD2SC-550D2SC-55XD2SK-650D2SK-65X
D3SC-1000D3SC-100XD3SS-1500D3SS-150X
D3SC-750-DTCD3SC-75X
D3SS-1000-DTCD3SS-100XD4SA-2000D4SA-200XD4SH-2500D4SH-250XD4SJ-3000D4SJ-300XD4SL-1500D4SL-150XD4ST-2000D4ST-200XD6SH-3500D6SH-350XD6SJ-4000D6SJ-400XD6SK-5000D6SK-5000D6SL-2500D6SL-250XD6ST-3200D6ST-320XD6SU-4000D6SU-400X
D6TA-1500 SUBD6TA-150X SUBD6TH-2000 SUBD6TH-200X SUBD6TJ-2500 SUBD6TJ-250X SUB
--
D6TA-1500D6TA-150XD6TH-2000D6TH-200XD6TJ-2500D6TJ-250X
--
Europe EquivalentModel
22222222222222223333333344444444446666666666666666666666666666
Number ofcylinders
44.5/36.544.5/36.550.8/36.550.8/36.550.8/36.550.8/36.560.4/36.560.4/36.560.4/36.560.4/36.561.9/42.861.9/42.860.3/54.060.3/54.065.1/54.065.1/54.060.4/50.860.4/50.861.9/63.561.9/63.560.4/50.860.4/50.861.9/63.561.9/63.563.5/50.863.5/50.868.3/55.668.3/55.674.7/55.674.7/55.668.3/55.668.3/55.674.7/55.674.7/55.668.3/55.668.3/55.674.7/55.674.7/55.680.6/57.080.6/57.068.3/55.668.3/55.674.7/55.674.7/55.680.6/57.080.6/57.063.5/50.863.5/50.868.2/55.568.2/55.574.7/55.674.7/55.680.6/57.080.6/57.063.5/50.863.5/50.868.2/55.568.2/55.574.7/55.674.7/55.680.6/57.080.6/57.0
Bore/Stroke,mm
222233334444
5.55.57.57.510101515101015152020252530301515202035354040505025253232404015152020252530301515202025253030
NominalHP
1450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/1750
Motor Speed(rpm)50/60 Hz
9.99.9
12.912.912.912.918.218.218.218.222.522.526.826.831.231.238.038.049.949.938.038.049.949.956.056.070.870.884.784.770.870.884.784.7
106.0106.0127.0127.0151.8151.8106.0106.0127.0127.0151.8151.8
56.0/28.056.0/28.070.8/35.470.8/35.484.7/42.484.7/42.4
101.2/50.6101.2/50.6
56.056.070.870.884.784.7
101.2101.2
Displacement@ 50 Hz, cu.m/h
11.911.915.615.615.615.621.921.921.921.9
--
32.332.337.637.645.645.659.959.945.645.659.959.967.267.285.085.0
101.6101.685.085.0
101.6101.6127.2127.2152.4152.4182.2182.2127.2127.2152.4152.4182.2182.2
67.6/33.867.6/33.885.5/42.785.5/42.7
102.2/51.1102.2/51.1122.1/61.5122.1/61.5
67.667.685.585.5
102.2102.2122.1122.1
Displacement@ 60 Hz, cu.m/h
2SSeries
3SSeries
4SSeries
6SSeries
6TSeries
93
ALL Series
LSeries
Mechanical Data
LA10-0200LA10-020ELA20-0200LA20-020ELA20-0300LA20-030ELA40-0300LA40-030ELA40-0400LA40-040ELA50-0400LA50-040E 2SCW-05502SCW-055E2SKW-07502SKW-075E3SCH-10003SCH-100E3SSH-15003SSH-150E3SC1-10003SC1-100E3SS1-15003SS1-150E4SAH-20004SAH-200E4SHH-25004SHH-250E4SJH-30004SJH-300E4SLW-15004SLW-150E4STW-20004STW-200E6SHH-35006SHH-350E6SJH-40006SJH-400E6SKH-50006SKH-500E6SLW-25006SLW-250E6STW-32006STW-320E6SUW-40006SUW-400E6TAW-1500 SUB6TAW-150E SUB6THW-2000 SUB6THW-200E SUB6TJW-2500 SUB6TJW-250E SUB6TKW-3000 SUB6TKW-300E SUB6TAW-15006TAW-150E6THW-20006THW-200E6TJW-25006TJW-250E6TKW-30006TKW-300E
Model
15 mm15 mm15 mm15 mm15 mm15 mm15 mm15 mm15 mm15 mm15 mm15 mm
7/8 7/8 7/8 7/8
1 1/81 1/81 1/81 1/81 1/81 1/81 1/81 1/81 1/81 1/81 1/81 1/81 3/81 3/81 1/81 1/81 3/81 3/81 3/81 3/81 3/81 3/81 5/81 5/81 3/81 3/81 3/81 3/81 5/81 5/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/81 3/8
Rotalock Discharge,inch
22 mm22 mm22 mm22 mm22 mm22 mm28 mm28 mm28 mm28 mm28 mm28 mm
1 1/81 1/81 1/81 1/81 3/81 3/81 5/81 5/81 3/81 3/81 3/81 3/81 5/81 5/82 1/82 1/82 1/82 1/81 5/81 5/82 1/82 1/82 1/82 1/82 1/82 1/82 5/82 5/82 1/82 1/82 1/82 1/82 5/82 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/81 5/8
Rotalock Suction,inch
460/330460/330460/330460/330460/330460/330460/330460/330460/330460/330460/330460/330553/330553/330553/330553/330680/370680/370710/370710/370653/370653/370680/370680/370650/485650/485670/490670/490690/515690/515680/485680/485725/490725/490760/540760/540760/565760/565771/570771/570740/540740/540740/540740/540771/570771/570903/602903/602903/602903/602903/602903/602962/612962/612756/547756/547756/547756/547756/547756/547815/596815/596
Length/Width,mm
385385385385385385385385385385385385395395395395443443443443443443443443495495495495495495495495495495490490545545540540490490545545540540569569569569619619619619569569569569619619619619
Height,mm
295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)295 x 279 (22.0)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)457 x 305 (25.5)457 x 305 (25.5)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.4)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)381 x 305 (25.5)
Base mounting(hole dia), mm
2.42.42.42.42.42.42.42.42.42.42.42.42.42.42.42.43.73.73.73.73.73.73.73.73.83.83.83.83.83.83.43.43.43.44.04.06.86.86.86.83.43.46.86.86.86.84.04.04.04.06.86.86.86.84.04.04.04.06.86.86.86.8
Oil Quantity,l
77777676797978788080818191919292
157157162162157157169169183183194194210210180180192192224224252252268268210210234234265265224224227227247247268268219219222222242242263263
Net Weight,kg
2SSeries
3SSeries
4SSeries
6SSeries
6TSeries
858584848787868688888989
100100101101175175180180175175187187210210221221237237207207219219251251279279295295237237261261294294254254257257277277300300249249252252272272295295
Gross Weight,kg
94
ALL Series
LSeries
Electrical Data
LA10-0200LA10-020ELA20-0200LA20-020ELA20-0300LA20-030ELA40-0300LA40-030ELA40-0400LA40-040ELA50-0400LA50-040E 2SCW-05502SCW-055E2SKW-07502SKW-075E3SC1-10003SC1-100E3SCH-10003SCH-100E3SS1-15003SS1-150E3SSH-15003SSH-150E4SAH-20004SAH-200E4SHH-25004SHH-250E4SJH-30004SJH-300E4SLW-15004SLW-150E4STW-20004STW-200E6SHH-35006SHH-350E6SJH-40006SJH-400E6SKH-50006SKH-500E6SLW-25006SLW-250E6STW-32006STW-320E6SUW-40006SUW-400E6TAW-15006TAW-150E6THW-20006THW-200E6TJW-250E6TJW-25006TKW-30006TKW-300E
Model
2.02.02.02.03.03.03.03.04.04.04.04.05.55.57.57.5
10.015.010.010.010.015.015.015.020.020.025.025.030.030.015.015.020.020.035.035.040.040.050.050.025.025.032.032.040.040.015.015.020.020.025.025.030.030.0
NominalHP
2SSeries
3SSeries
4SSeries
6SSeries
6TSeries
Motor Speed(rpm)
1450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/17501450/1750
5.75.75.54.57.26.87.17.39.39.58.68.9
12.813.115.716.417.918.922.022.025.927.225.025.031.631.642.442.448.048.331.135.134.939.663.663.675.375.389.489.445.451.658.364.966.878.028.829.436.337.744.642.151.854.5
MRA34.034.034.034.048.048.048.048.062.062.062.062.067.067.077.077.0
--------
158.3158.3180.0180.0200.0200.0125.0125.0143.0143.0275.0275.0275.0275.0355.0355.0173.0173.0253.0253.0275.0275.0157.0157.0157.0157.0178.0178.0275.0275.0
Min LRA37.637.637.637.653.053.053.053.068.568.568.568.574.174.185.385.383.083.0
106.0106.0138.0138.0138.0138.0175.0175.0199.0199.0221.0221.0140.0140.0160.0160.0304.0304.0304.0304.0393.0393.0192.0192.0284.0284.0304.0304.0173.0173.0173.0173.0197.0197.0304.0304.0
Max LRA9.99.99.57.8
12.511.812.312.616.116.414.915.422.122.727.228.4
------------------------------
60.561.776.279.293.788.4
103.6115.6
MRA59.059. 059. 059. 083.083.083.083.0
107.0107.0107.0107.0116.0116.0134.0134.0
------------------------------
331.0331.0331.0331.0376.0376.0579.0579.0
Min LRA64.064.064.064.091.091.091.091.0
117.0117.0117.0117.0128.0128.0147.0147.0
------------------------------
361.0361.0361.0361.0410.0410.0632.0632.0
Max LRA6.86.86.65.48.68.28.58.8
11.211.4
--
15.415.718.819.720.420.427.427.429.129.137.337.337.937.950.950.957.658.037.342.141.847.576.376.390.490.4
107.0107.054.561.970.177.880.293.634.635.343.645.253.550.559.266.1
MRA43.043.043.043.063.063.063.063.068.968.9
--
77.177.187.087.0
--------
203.0203.0228.0228.0243.0243.0163.0163.0180.0180.0332.0332.0332.0332.0436.0436.0214.0214.0325.0325.0332.0332.0190.0190.0190.0190.0216.0216.0332.0332.0
Min LRA48.548.548.548.569.569.569.569.576.176.1
--
85.285.296.596.596.096.0
112.0112.0138.0138.0138.0138.0224.0224.0252.0252.0268.0268.0180.0180.0199.0199.0367.0367.0367.0367.0482.0482.0236.0236.0359.0359.0367.0367.0210.0210.0210.0210.0238.0238.0367.0367.0
Max LRA12.012.011.69.5
15.114.314.915.319.520.0
--
26.827.533.034.435.835.847.947.950.950.965.365.366.466.489.089.0
101.0101.064.672.972.482.3
134.0134.0158.0158.0188.0188.094.4
107.2121.4134.7140.0164.060.561.776.279.293.788.4
103.6115.6
MRA75.075.075.075.0
109.0109.0109.0109.0120.0120.0
--
135.0135.0151.0151.0
--------
354.0354.0397.0397.0424.0424.0282.0282.0312.0312.0579.0579.0579.0579.0761.0761.0370.0370.0562.0562.0579.0579.0331.0331.0331.0331.0376.0376.0579.0579.0
Min LRA84.084.084.084.0
121.0121.0121.0121.0131.0131.0
--
147.0147.0168.0168.0165.0165.0194.0194.0238.0238.0238.0238.0386.0386.0433.0433.0462.0462.0312.0312.0345.0345.0632.0632.0632.0632.0830.0830.0409.0409.0622.0622.0632.0632.0361.0361.0361.0361.0410.0410.0632.0632.0
Max LRA----------------
17.918.922.022.025.927.225.025.031.631.642.442.448.048.331.135.134.939.663.663.675.375.389.489.445.451.658.364.966.878.028.829.436.337.744.642.151.854.5
MRA------------------------
164.0164.0183.0183.0196.0196.0118.0118.0137.0137.0268.0268.0268.0268.0351.0351.0166.0166.0243.0243.0268.0268.0159.0159.0159.0159.0181.0181.0268.0268.0
Min LRA----------------
83.083.0
106.0106.0138.0138.0138.0138.0178.0178.0200.0200.0213.0213.0132.0132.0154.0154.0292.0292.0292.0292.0383.0383.0184.0184.0273.0273.0292.0292.0174.0174.0174.0174.0197.0197.0292.0292.0
Max LRA
EWL/AWM/TFD380-420, 3ph, 50Hz
EWL220-240, 3ph, 50Hz
EWK380-420, 3ph, 60Hz
EWK220-240, 3ph, 60Hz
AWD/TFD440-480, 3ph, 60Hz
aprefrigeration@emersonclimate.comFebruary 2010
Emerson Climate Technologies,
Asia Pacific Headquarters
10/F, Pioneer Building,
213 Wai Yip Street,
Kwun Tong, Kowloon, Hong Kong.
Tel: (852) 2866 3108
Fax: (852) 2520 6227
Australia
Emerson Climate Technologies Australia Pty Ltd
Unit R7, 391 Park Road
Regents Park, NSW 2143, Australia
Tel: (61-2) 9795 2800
Fax: (61-2) 9738 1699
China - Shanghai
c/o Emerson Climate Technologies (Suzhou) Co. Ltd
Shanghai Sales Office
11th Floor, Innov Tower,
1801 Hong Mei Road,
XuJiaHui District
Shanghai 200233, P. R. China
Tel: (86-21) 3395 0000
Fax: (86-21) 3367 8100
China - Beijing
c/o Emerson Climate Technologies (Suzhou) Co. Ltd
Beijing Sales Office
Room 310, Canway Building
66 Nan Lishi Road, Xicheng District
Beijing 100045, China
Tel: (86-10) 6805 7825
Fax: (86-10) 6805 6301
China - Guangzhou
c/o Emerson Climate Technologies (Suzhou) Co. Ltd
Guangzhou Sales Office
Room 508-509, R&F Yinglong Plaza
No. 76 Huangpu Road West,
Guangzhou 510623, PRC.
Tel: (86-20) 2886 7668
Fax: (86-20) 2886 7622
China - Suzhou
c/o Emerson Climate Technologies (Suzhou) Co. Ltd
Suzhou Plant
No. 69 Suhong West Road ,
Suzhou Industrial Park , Suzhou ,
Jiangsu Province , P.R.C. 215021 China.
Tel: (86-512) 6257 5505
Fax: (86-512) 6257 5506
Contact us at:
India - PUNE
Emerson Climate Technologies (India) Ltd
Plot No. 23, Rajiv Gandhi Infotech Park,
Phase - II, Hinjewadi,
Pune 411 057, Maharashtra,India
Tel: (91-20) 4200 2000
Fax: (91-20) 4200 2099
India - Mumbai
Emerson Climate Technologies (India) Ltd
Unit No. 4,5,6 & 7, Bhaveshwar Arcade
LBS Marg, Opp. Shreyas Cinema
Ghatkopar (West)
Mumbai 400 086, Maharashtra, India
Tel: (91-22) 2500 6630/ 2500 6632
Fax: (91-22) 2500 6570
Indonesia
PT. Emerson Indonesia
Wisma Kota BNI 46 16th floor Suite 16.01
Jl. Jend.Sudirman Kav.1.Jakarta 10220
Tel: (62)21-2513003 ext.6000
Fax: (62)21-2510622
Japan
c/o Emerson Japan Ltd
Shin-yokohama Tosho Building No. 3
3-9-5 Shin-Yokohama, Kohoku-ku
Yokohama 222-0033 Japan
Tel: (81-45)475 6371
Fax: (81-45)475 3565
South Korea
c/o Emerson Electric (South Korea) Ltd
12F, Narae B/D, 719-1, Yeoksam-dong
Gangnam-gu, Seoul, South Korea 135-080
Tel: (82-2) 3483-1500
Fax: (82-2) 592-7883 / 592-7886
Malaysia
c/o Emerson Electric (Malaysia) Sdn. Bhd.
Level M2, Blk A, Menara PKNS-PJ
Jalan Yong Shook Lin
46050 Petaling Jaya, Selangor, Malaysia
Tel: (60-3) 7949 9222
Fax: (60-3) 7949 9333
Taiwan
c/o Emerson Electric (Taiwan) Co. Ltd
5th Floor, No.2 Jen Ai Road
Section 4, Taipei 10650, Taiwan
Tel: (886-2) 2325 9555
Fax: (886-2) 2702 9630/ 2784 0022
Thailand - Rayong Plant
c/o Emerson Electric (Thailand) Ltd
No. 24 Moo 4 Tambol Pluakdaeng, Amphur
Pluakdaeng, Rayong 21140, Thailand
Tel: (66-38) 957 000
Fax: (66-38) 954 251
Thailand - Bangkok
c/o Emerson Electric (Thailand) Ltd
34th Floor Nation Tower
1858/133 Bangna Trad
Bangkok 10260 , Thailand
Tel: (66-2) 716-4700
Fax: (66-2) 751-4240
Recommended