SCADAPack controllers combine the monitoring and communications capabilities of remote terminal units (RTUs) with the processing and data-logging power of programmable logic controllers (PLCs), providing superior functionality wherever remote processes require automatic supervision and autonomous control
Citation preview
Intelligent Field Controllers for Secure & Reliable Remote OperationsSCADAPackCompact, versatile controller for telemetry and remote SCADA solutions
SCADA Controllers for Challenging ApplicationsProviding reliable data collection, monitoring and control is a crucial component in any SCADA system. However, when critical infrastructure is dispersed over a wide area, often accessible only through a variety of communication media, unique chal-lenges are faced. How current is the data and will it be lost if communication is interrupted? How can unauthorised control or hacking attempts be prevented? Will this work at remote sites where power is very limited?
High cost of engineering and operatingEver-expanding SCADA systems, focused on gathering process data from geographically dispersed remote sites, are placing increased demands on engineering and maintenance personnel. In an environment of shrinking operational budgets and rising labour and material costs, finding the right controller that can do more for less is crucial.
Operating in challenging environmentsControllers are typically situated in hard-to-access remote loca-tions; subject to extremes in weather conditions and harsh, hazardous industrial environments.
With energy costs on the rise, alternate sources such as solar-power are being increasingly exploited wherever challenging power conditions exist. Controllers that consume less power and can easily interface with solar infrastructure are needed.
Increased pressure from security threats & regulatory requirementsIn recent years, government agencies have been instituting strin-gent environmental, security and safety regulations. As a result of several high-profile cyber-attacks and environmental disasters, public and governmental awareness is at its highest level. Non-compliance to the regulations can be dangerous for users and the environment, and very expensive if fines are levied.
SCADAPack controllers combine the monitoring and commu nications capabilities of remote terminal units (RTUs) with the processing and data-logging power of programmable logic controllers (PLCs), providing superior functionality wherever remote processes require automatic supervision and autonomous control.
03
The product line is designed for use in environments with extreme temperatures and humidity, integrates easily with most third party field and networking equipment, and can operate under low or restricted power conditions.
All SCADAPacks offer Class I, Division 2 Hazardous Area Rating and are covered by an industry-benchmark 3 year warranty.
SCADAPack controllers offer an array of flexible connectivity and programming features that reduce design and implementation time:
• Wide range of connectivity options: easily retrofit into legacy system, or expand current system
• Integrated Trio wireless radios: extend opera-tional range without affecting control panel footprint
• Open protocols: interface to most 3rd-party SCADA infrastructure
• Flexible programming options: easy-to-use, multi-language tools for all skill levels
Open SCADAModbus DNP3
04
> Make the most of your resources
• Flexible connectivity options
• Built-in radio
• Open communication protocols
• Choice of programming environments
Ethernet SDI-12
EFM (Enron) Modbus
USB
Leased-line
PSTN
DF1
HART
3rd-Party Radios
To help counter the effect of ever-rising energy, operational and main-tenance costs, SCADAPack controllers offer a standard feature set that allows you to exploit alternate energy sources, increase system efficiency and reduce the frequency of costly on-site visits.
SCADAPack controllers help to reduce total cost of deployment with:
• Gas flow metering (O&G) or pump control (W&WW) combined with data logging, PLC control & RTU communication in one device
• An integrated data-logger provides enhanced control and data logging capabilities that increase operational efficiency and reduce cost
• Remote configuration and diagnostics features allow system deployment and maintenance tasks to be executed from a centralised location over existing communication infrastructure.
• Low-power models achieve significant cost savings due to the smaller solar panel/battery size required to power the unit
> Ensure secure and reliable data from field to control room
SCADAPack controllers provide tools to ensure that remote communication links are not compromised by malicious intent or interference from other communi-cation networks:
• Enhanced security suite: IEEE1711 encryption & IEC62351 authentication for maximum system security mitigates effects of interference with data monitoring and control commands
• Time-stamped event logging provides audit trail of operational data changes and other key data reliability indicators
ClearSCADAIEC 61131-3
E Configurator3rd-party SCADA Host
SCADAPack 300E & ES
SCADAPack 100, 32, 300 & 4203
CommunicationInfrastructure
Ethernet LAN/WANRadio, Hard-Wired,
PSTN, Leased-line, etc.
ClearSCADATelepace Studio
Firmware LoaderIEC 61131-3
3rd-party SCADA HostSCADALog
RealfloProductionPlus
CentralisedServer
05
> Control costs of operation and maintenance
•Controller and sensor all in one package
• Configure remotely from central location
Rod Pump Control
Plunger Lift Control
Progressive CavityPump Control
Custody TransferGas Flow Computers
SCADA Host
Electric SubmersiblePump Control
SCADAPack controllers are the foundation for a range of solutions offering specific software and configura-tion tools to enhance performance in oil and gas and water/wastewater applications.
Digital Oil Field Solutions
Electronic Flow MeasurementSchneider Electric offers a flexible EFM solution that tightly integrates controller, multi-variable sensor and gas flow computer algorithm and configuration GUI.
With the Realflo gas flow measurement software, SCADAPack controllers can become a fully functional gas flow computer with up to 10 gas flow runs available on select models. EFM functionality works concurrently with the controller’s logic code for maximum flexibility.
The SCADAPack 4203 combines a Modbus multivariable sensor with a PLC to function as a highly integrated gas flow computer. A second flow run may be accessed with the addition of a 4102 Modbus multivariable sensor.
The SolarPack 410 is a cost-effective, out-of-the-box, single run flow computer designed for use in installations where solar is the only power source and operator access is difficult.
Well Production OptimisationProductionPlus is an integrated hardware and software solution that increases safety, improves environmental compliance and extends the life cycle of the well. Leveraging the power of the SCADAPack 4203 gas flow computer and the SCADAPack 300 range of controllers, ProductionPlus offers a highly distributed and scalable well automation solution for 1 to 30+ wells per pad.
Realflo is compliant with API21.1 custody transfer and AGA3, AGA7, AGA8, NX 19 gas flow calculation standards.
06
Enhanced Solutions for Oil & Gas...
Water/Wastewater Solutions
Optimised for remote pumping networksSCADAPack E controllers offer all the features and benefits of the SCADAPack with the added capabilities of DNP3 and IEC 60870-5. They have an embedded historian allowing time-stamped event logging for extended periods of time. Distributed Network Protocol (DNP3) provides flexible, secure communications between devices. Ensuring that there are never holes in the data even when communication links go down, DNP3 reduces the number of costly and time-consuming maintenance trips to the field.
AGA12 encryption protects DNP3 data transmission using unique security keys, ensuring data integrity for billable applications or critical operations.
Lift Station ControlFlowStation is a complete pump station controller ideal for use in storm and wastewater lift stations and pump-up applications. This economical, convenient control solution manages power usage and related costs while minimising energy consumption during peak demand periods. FlowStation supports custom function-ality, allowing for the creation of simple or feature-rich web pages viewable from a local touch screen, BlackBerry, or other remote web browser.
Restoration to Natural Environment
Waste Water Treatment
Long-rangeWireless
Long-range Wireless
Irrigation /Water Management
SewageLift Station
Domestic& Commercial
Tank orBooster Station
Water Treatment
Pump UpControl
Pressure Distribution System
Pump DownControl
Enterprise SCADASoftware
Enterprise SCADASoftware
Tank and LevelMeasurement Control
WirelessInstrumentationMonitoring
WirelessInstrumentationMonitoring
Pumping andRecovery Station
Gate / CanalControl
07
...and Water & Wastewater
• Modbus core database, DNP3 level 2 layer, optional DF1 support• Programming and configuration: TelePACE Studio, IEC61131-3, C/C++• O&G-focused apps: Realflo and ProductionPlus Well Optimisation
SCADAPack Controllers
Modbus-centricSCADAPack 100, 300, 32 & 4203
314 330 334 350 357 32P 32 P4 32 P4A 32 P4B 100
Analog Inputs
On-board1 8: 0-20mA,4-20mA
0-5V0-10V
n/a 8: 0-20mA,4-20mA
0-5V0-10V
5: 0-10V,0-20mA
1: 0-32.7VDC
5: 0-10V,0-20mA
1: 0-32.7VDC8: 0-20mA,
4-20mA0-10V0-5V
n/a 8: 0-20/ 4-20mA
or 0-5/1-5V
8: 0-20mA/0-10V
1: 0-32.768V
8: 0-20/ 4-20mA
0-5/0-10V
3: 0-20/ 4-20mA
0-5/1-5 VDC1: 0-32.7
VDC
Analog Outputs
On-board1 2: 0-20mA4-20mAOptional
n/a 2: 0-20mA4-20mAOptional
2 or 4: 0-20mA4-20mAOptional
n/a 2: 0-20mA4-20mAOptional
n/a
Digital Inputs
On-board1 16: 12/24V48V
115/125V240V
n/a 16: 12/24V48V
115/125V240V
8: Dry contact,
Shared withoutput points.
8: Dry contact,
shared withoutput points32: (12/24V,
48V, 115/125V,
240V)
3: 24VAC/ 30VDC,
shared with Counterinputs1: 30V
interrupt
3: 24VAC/ 30VDC,
shared with Counterinputs1: 30V
interrupt16:
12-24/120/ 220V-VAC
3: 24VAC/ 30VDC,
shared with Counterinputs1: 30V
interrupt32: dry contact
Shared with outputs
3: 24VAC/ 30VDC
Shared with Counter inputs,1: 30V
interrupt input32: 12/24V,
48V,115/125V,
240V
6: selectable as input or
output
Digital Outputs
On-board1 10: dry contact or
10: solid-state
n/a 10: dry contact
or solid-state
8: open drain,Shared withinput points.
8: open drain,Shared withinput points.
16: dry contact
1: ControllerStatus Output
1: ControllerStatus Output
12: Dry contact
1: ControllerStatus Output
32: dry contact
Shared with inputs
1: ControllerStatus Output
16: Dry contact
6: selectable as input or
output
Frequency Inputs
On-board1 1: 0-10Hz or 0-5kHz (dry contact) 3: 0-5 kHz shared with digital inputs, 1: 0-500Hz, interrupt input 1: 0-6 kHz turbine
or dry contact
General
Turbine Inputs
2: 0-10kHz (turbine or dry contact) n/a 1
Serial Ports 2: RS232/RS485
2: RS232/RS485 1: RS232
1: RS485, 1: RS232/RS485, 1: RS232
2: RS2321: RS232/
RS485
3: RS232, 1: RS232/RS485 2: RS2321: RS232/
RS485
1: RS2321: RS232/
RS485
USB Ports 1: Peripheral 1: Host, 1: Peripheral n/a
Ethernet Ports
n/a 1, 10/100BaseT 1: 10BaseT n/a
EFM Flow Runs
4 10 1
Programming Software
TP Studio, IEC61131, C++ TP Studio,IEC61131, C
Modbus Yes
DNP3 Level 2
1 Number of on-board I/O may be further expanded for any SCADAPack using Expansion I/O Modules.
Refer to individual product data sheets for detailed specifications.
08
> Selection Guide
• DNP3 Level 4 core database, Modbus layer, IEC 60870-5-101/103/104, optional DF1 support• Programming: IEC61131-3, configuration: E Configurator• DNP3 Secure Authentication & IEEE 1711 (AGA12) support
SCADAPack Controllers
DNP3-centricSCADAPack 300E & SCADAPack ES
314E 330E 334E 350E 357E ES
Analog Inputs
On-board1 8: 0-20mA,4-20mA
0-5V0-10V
n/a 8: 0-20mA,4-20mA
0-5V0-10V
5: 0-10V,0-20mA
1: 0-32.7VDC
5: 0-10V,0-20mA
1: 0-32.7VDC8: 0-20mA,
4-20mA0-10V0-5V
4, 6, or 12: 0-5V,1-5V, 0-20mA,
4-20mA
Analog Outputs
On-board1 2: 0-20mA4-20mAOptional
n/a 2: 0-20mA4-20mAOptional
2 or 4: 0-20mA4-20mAOptional
2 or 4: 0-20mA,4-20mA
Digital Inputs
On-board1 16: 12/24V48V
115/125V240V
n/a 16: 12/24V48V
115/125V240V
8: Dry contact,Shared with
output points.
8: Dry contact,shared with
output points32: (12/24V, 48V,
115/125V,240V)
8, 16, or 32:10-30VDC,shared with
Counter Inputs
Digital Outputs
On-board1 10: dry contact or10: solid-state
n/a 10: dry contactor solid-state
8: open drain,Shared withinput points.
8: open drain,Shared withinput points.
16: dry contact
2, 8 or 16:DPDT Relay,
(NO/Common/NC)
Frequency Inputs
On-board1 1: 0-10Hz or 0-5kHz (dry contact) n/a
General
Turbine Inputs
2: 0-10kHz (turbine or dry contact) n/a
Serial Ports 2: RS232/RS485 2: RS232/RS485 1: RS232 1: RS485, 1: RS232/RS485, 1: RS232 3: RS2322: RS232/RS422/
RS485
USB Ports 1: Peripheral 1: Host, 1: Peripheral n/a
Ethernet Ports
n/a 1: 10/100BaseT 2: 10/100BaseT
EFM Flow Runs
n/a
Programming Software
IEC61131
Modbus Yes
DNP3 Level 4
1 Number of on-board I/O may be further expanded for any SCADAPack using Expansion I/O Modules.
Refer to individual product data sheets for detailed specifications.
09
FlowStation
Pump Controller
Pumps Supported 1, 2, or 3 (lead, lag, standby)
Control Modes Pump-down (Lift Station), pump-up (Reservoir)
Pump Alternation Automatic or fixed
SMS and E-mail Alarm reporting and acknowledgement (requires optional GPRS modem)
Event Logs Operator, Event Type, Time and Date of event
BlackBerry® Interface BlackBerry® Bold hand-held browser for basic viewing and alarm acknowledgement (GPRS modem required)
Web Server Web interface for configuration, monitor, and control
Alarms Logging and assignable alarm priorities
Level Control Level sensor or float switch-based
Level Transducer Signal Input 4-20mA, 0-20mA, 1-5V
Serial Ports 3: for connection to SCADA Radios, local smart sensors and auxiliary devices such as motor protection relays or remote I/O
Ethernet 1: 10/100BaseT for web-browser access to local touch screen, laptop or Ethernet radio to corporate WAN
Communication Protocols SCADA-ready with Modbus and Modbus/TCP
GPRS Modem 1: optional
Web/LAN Security User logon authentication, and friendly IP list
USB Memory Stick FlowStation auto-configuration, event and alarm log recording
Commissioning I/O simulation and test modes
Flush Valve Operation Support for automatic or controller-based
Setpoints Pump Down/Up, configurable in 3 groups for operation during wet/dry season, or minimising of peak power consumption
Lift Station Maintenance Fat-ring reduction and pump-down sludge removal algorithms to reduce frequency of wet well cleaning
Pump Performance Monitoring Pump start statistics, run time accumulations and history logs; pump current monitoring (optional)
ClearSCADA Enhanced Integration ClearSCADA host software provides pre-configured lift station templates for rapid rollout of new installations
Operating Environment FlowStation 110 -40°C to 70°C (-40°F to 158°F)Touch Screen 0°C to 45°C (32°F to 113°F)GPRS Modem -30°C to 70°C (-22°F to 158°F)
Safety Certifications Hazardous LocationsNorth America Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations. Temperature Code T4 per CSA Std C22.2 No. 213-M1987 / UL1604 UL listed and CSA certified to the following standards: • CSA Std. C22.2 No. 213-M1987 - Hazardous Locations. • CSA Std. C22.2 No. 142-M1987 - Process Control Equipment. • UL Std. No. 1604 - Hazardous (Classified) Locations. • UL Std. No. 508 - Industrial Control Equipment.Europe ATEX II 3G, Ex nA IIC T4 per EN 60079-15, protection type n (Zone 2) Does not include Wireless versions.Australia IECEx, Ex nA IIC T4 per IEC 60079-15, protection type n (Zone 2) Does not include Wireless versions. (pending)
Lift Station Solutions
FlowStationThe FlowStation is a lift station pump controller for up to 3 Pumps with web browser interface and alarming via SMS and email.
11
4102 SCADAPack Transmitter 4203-DR SCADAPack Transmitter 4203-DS SCADAPack Transmitter
Description Modbus Multivariable Transmitter Gas Flow Computer with integrated Modbus Multivariable Transmitter
Gas Flow Computer with integrated Modbus Multivariable Transmitter
Sensor Types Process Pressure, Differential Pressure and Temperature
Gas Flow plus Process Pressure, Differential Pressure and Temperature
Gas Flow plus Process Pressure, Differential Pressure and Temperature
Internal PLC No Yes Yes
Features
Analog Inputs (AI) n/a 1: internal (supply voltage) 1: internal (supply voltage)2: external (0 - 5V) inputs
Analog Outputs (AO) 1: 0 - 20mA, optionalFor use with PID control or as general analog output.
1: 0 - 20mA.For use with PID control or as general analog output.
n/a
Turbine Meter Counter Inputs (TI)
n/a One 1: (point shared with DI/DO)
Counter Inputs (CTRI) n/a 1: (point shared with DI/DO) 1: (point shared with DI/DO)
Digital Inputs (DI) n/a 1: (point shared with CTRI/DO) 2: (points shared with DO/TI & CTRI/DO)
Digital Outputs (DO) n/a 1: (point shared with CTRI/DI) 2: (points shared with DI/TI & DI/CTRI)
Communications
Serial Port 1: RS232/485 2: RS232/485 2: RS232/485
Serial Protocol Modbus RTU Modbus RTU/ASCII, DNP3, DF1 Modbus RTU/ASCII, DNP3, DF1
Ethernet Port 10BaseT, optional n/a n/a
Ethernet Protocols Modbus/UDP; Modbus RTU in UDP n/a n/a
Functional
Gas Flow Calculations n/a AGA-3 (1992/2000) orifice plate, V-Cone and AGA-7 turbine meter
AGA-3 (1992/2000) orifice plate, V-Cone and AGA-7 turbine meter
Gas Compressibility Calculations
n/a AGA-8 (1992) and NX-19 AGA-8 (1992) and NX-19
Event/Alarm History Logs n/a 35 days hourly history, 35 days daily history, 700 events and 300 alarms (as per API 21.1)
35 days hourly history, 35 days daily history, 700 events and 300 alarms (as per API 21.1)
13
Electronic Flow Measurement
SCADAPack TransmittersSCADAPack Transmitters combine a Modbus multivariable transmitter with an integrated SCADAPack controller to create a complete gas flow computer for Class 1, Division 1 hazardous areas. The multivariable transmitter is also available separately (model 4102) allowing it to used with any choice of SCADAPack for multiple flow run installations.
Electronic Flow Measurement SoftwareRealflo configuration software is used to add a gas flow computer to any SCADAPack controller (SCADAPack E excluded).
Realflo
EFM Software
Flow Calculations AGA-3 (1985)• AGA-3(1992/2000) • AGA-7• V-Cone • WaferCone
Density Calculations • AGA-8(1992)• NX-19
Measurement Update Once per second; up to 10 Gas Flow Runs
AGA 3, 7, V-Cone, Wafer Cone Calculation Update
Once per second
Alarm and Event Log 300/700 (per API 21.1 and Measurement Canada)
Hourly History 35 days
Daily History 35 days
Gas Quality History • Hourlygascomponentaveraging
Passwords Four levels with log of user ID during access
Hardware • SCADAPack100,SCADAPack32,SCADAPack300,SCADAPack4203
Multivariable Transmitter Seamless integration of SCADAPack Multi-Variable Transmitter (including configuration and calibration) or any similarly mapped Modbus-based MVT.
14
SolarPack 410
Description Flow Computer
Flow Calculations AGA-3 1992/2000 orifice plate and V-Cone
Density Calculations AGA-8, 1992 (detailed) and NX-19
Event/Alarm/History Logs 35 days hourly history, 35 days daily history, 700 events and 300 alarmsAPI 21.1, BLM Onshore Order #5 and EUB Directive 17
FeaturesConfiguration Interface Realflo 6.40 and newer
Protocols COM2 and COM3: Modbus RTU/ASCII
Temperature Measurement Terminations for one: RTD input
Counter Input 1: Turbine Meter
Gas Sampler Output 1: selectable as sourcing or sinking, configurable Pulse Width
Communication Ports Com 1: Direct to internal sensor or RS-485, 2-wire, half duplex to external sensor Com 2: For optional internal spread spectrum radioCom 3: Integrated Bluetooth wireless technology
Bluetooth Communication General : Radio modem compatible with Bluetooth wireless technology enabled products.
Distance: Bluetooth Class 1. Up to 100m (330 ft.) (when communicating with another Class 1 device)
Antenna: Integrated chip antenna
Radio Optional integrated Trio K-Series 900 MHz Spread Spectrum or FreeWave FGR09CSU 900MHz spread-Spectrum, or third-party radio connected to Com2
Battery Charger Solar Panel Power: 32W max. Shunt regulation, temperature compensated. Battery type: DIP switch-selectable for Cyclon Pure Lead, Gelled Electrolyte (Gel) or Absorbed Glass Mat (AGM)
Display Backlit LCD, 2 lines X 20 characters, indication of flow data, charging states
Enable Input Non-contacting wake-up switch, power management
Sensor PerformanceAccuracy Differential pressure ranges 200 to 840 inH2O ±0.05% of Span for Spans ≥10% of URL
Differential pressure range 30 inH2O ±0.10% of Span for Spans ≥10% of URL Absolute pressure ranges 30 inH2O ±0.05% of Span for Spans ≥10% of URL
Power
System Voltage 13.5V nominal
Power Consumption 108mW with Integrated sensor interface, gas flow calculations, display for 15 minutes per week and Bluetooth communications for 7.5 minutes per week 130mW with external sensor version, as above
GeneralEnvironment SolarPack 410 (not including the display and battery)
5% RH to 95% RH, non-condensing, –40oC to 55oC (–40oF to 131oF) Display: –20oC to 55oC (–4oF to 131oF)
Approvals and Certifications
Safety • Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D Hazardous Locations• cCSAus• Single Seal Compliance Certification under ANSI/ISA – 12.27.01, with maximum working pressures up to 21MPa (3000PSI).
External sensor version only.
Electronic Flow Measurement
SolarPack 410The SolarPack 410 is a solar powered single run flow computer in a NEMA 4 enclosure complete with a local interface and intelligent battery charging.
ProductionPlus
Gas Well Optimisation
Well Optimisation • Gaswelloptimisationforthelifeofthewell• OperatesinManualControl,Intermitter,AdvancedIntermitterandPlungerControl• Scalablesolutionaccommodatessinglewellsorlargemulti-wellpadsupto30wells
Wireless Sensors • Accutechsensorsforwellheadpressures,plungerarrivalsensors,andliquidstoragetanklevel
Tank Level Monitoring • Singleordualfloat,tanklevelmonitoringwithsetpointalarmsincludingautomaticpadshut-in
Well Controllers • SCADAPack4203isusedforeachwelltoprovidewelloptimisationandcustodytransferelectronicflowmeasurement• SCADAPack4203platformrunstheProductionPlusControllerapplicationandRealfloFlowComputerapplication
Pad Controller • SCADAPack300monitorsallAccutechsensorsandnetworksthisdatato4203wellcontrollers• ProvidescommunicationgatewaybetweentheSCADAHostandnetworkofwellcontrollers• ModbusOperatorInterfaceofferslocalcontrolanddetailedplungerarrivallog
Radio Communications • TrioserialorEthernetdataradioconnectswellpadtoSCADAHost
SCADA Host • ClearSCADASCADAHosttemplatemimicstheProductionPluscontrolinterface• DataloggingateachwellcontrollerisretrievedbytheHostfortrendingandplungerarrivalhistory
15
Well Pad Optimisation Solutions
ProductionPlusProductionPlus is a gas well optimisation solution that integrates SCADAPack, Trio, and Accutech hardware with a software application that results in a configu-rable solution selected from templates for typical single well and multi-well pad installations.
Schneider Electric
Telemetry & Remote SCADA Solutions48 Steacie Drive, Kanata, Ontario K2K 2A9 Canada Direct Worldwide: 1 (613) 591-1943Fax: 1 (613) 591-1022Toll Free within North America: 1 (888) 267-2232www.controlmicrosystems.com
Document Number M01012-18 May 2011 tk