Installation, Operation and Maintenance Instructions
– Read and Save These Instructions –
This manual is provided to acquaint you with the Quest DEH 3000R so that installation, operation, and maintenance can proceed successfully. Ultimate satisfaction depends on the quality of installation and a thorough understanding of this equipment.
Quest DRY 150
Installation, Operation and Maintenance Instructions
4201 Lien RdMadison, WI 53704 1-800-533-7533www.QuestProtect.com sales@thermastor.com
– Read and Save These Instructions –
Specifications subject to change without notice.TS-721
08/111
Quest DEH 3000R Digital Control
Quest DEH 3000R Digital Control:
• Digitalcontrolofrelativehumidity(DigitalSet-Point)
• Fan/Filteroperation
• Programmableventilationtimer
• Sleekdesign
• Large,easy-to-readbacklitLCDdisplay
• Hightemperaturecut-out
• Dryoutcycletimer
• Autoreboot
questquest
questquest1-800-533-7533
2www.QuestProtect.com
sales@questprotect.com
Quest DEH 3000R Installation, Operation and Maintenance Instructions
Table of Contents
1.Specifications.................................................................. 32.Installation...................................................................... 3 2.1 ControlPanelInstallInstructions............................. 3 2.2 RemoteSensorInstallInstructions........................... 4 2.3 RemoteSensorUsage............................................. 4 2.4 RemoteSensorWiringInstructions.......................... 4 2.5 ControlPanelWiringInstructions............................ 5 2.6 AuxiliaryRelayOperation....................................... 6 2.7 Dehumidifierlock-OFForlock-ON........................ 7 2.8 Testing.................................................................... 83.Operation........................................................................ 9 3.1 Display................................................................... 9 3.2 Setting.................................................................. 10 3.3 PersonalSettingsReferenceList............................ 10 3.4 On/OffandDisplaySettings.................................. 10 3.5 SettingClock........................................................ 10 3.6 AdjustingtheRelativeHumidity............................ 11 3.7 FanSettingandOperation.................................... 11 3.8 DamperOperationandSetting(Ventilation)......... 12 3.9 TemperatureCutoutProgramming........................ 14 Warranty............................................................... 15
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
3www.QuestProtect.com
sales@questprotect.com
questquest
24VACYellowWire 24VACRedWire
DamperWhiteWire(Optional.See
warningbelow)
DehumidifierBlueWire
FanGreenWire
ON-Detect
Common
OFF-Detect
NormallyOpen
Common
NormallyClosed
OptionalUse
OptionalUse
MountingHole
MountingHole
1. SpecificationsPart#(P/N) 4028531Model: QuestDEH3000RDigitalControl
Electrical: 24VAC
MaxCurrent–DMP,COMP,FAN: 1Ampeach
HumidityOperatingRange: 10–95%
HumidityControlRange: 35–70%
HumidityAccuracy: ±5%Output: 3Amps24VACAux.RelayCapacity 5AmpsTempRange/ 30°-90°F,2%AccuracySize 4.95"Lx1.06"Wx4.19"H
FOR HVAC INSTALLER ONLY:
2. InstallationInstalltheQuestDEH3000Rremotesensorinacentralareaofthestructurewhereitwillsensetherelativehumidityofthestructureaccurately.DonotinstalltheremotesensorwhereitmaynotaccuratelysensetherelativehumiditysuchasnearHVACsupplyregisters,nearexteriordoorsandwindows,ornearapoolorspa.Installinaccordancewithallapplicablecodesandstandards.
2.1 Control Panel Install Instruc-tions1. Separatethefrontpanelfromtheback
panelbydepressingthemiddlesectionsofthetopandbottomofthefrontpanel.
2. Locatethewiringaccessholeinthewallorotherflatmountingsurface.Placethebackpanelintopositionanddrilltheappropriatemountingholes.
3. Insertthescrewsandtighten.Levelasnecessary.
4. Maketheelectricalconnectionstotheterminalsonthebackpanelasshownintheapplicablewiringdiagram(seeSections2.2-2.4).
5. Testtheinstallation(seeSection2.5).
questquest1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
4www.QuestProtect.com
sales@questprotect.com
2.2 Remote Sensor Install InstructionsThis section is applicable only to customers who have purchased a remote sensor package. The standard DEH 3000 controller does not offer remote functionality.
2.3 Remote Sensor Usage
IMPORTANT!•Theuseofspraypaintonthesensorhousingmaydamagethesensorandisnotcoveredbytheproductwarranty.
Theremotesensingoptionisusedwhenaninstallationrequiresmountingthehumidityandtemperaturesensoroutoftheconditionedspaceorwhenitisdesiredtospecificallymonitorandcontroltheconditionsataparticularlocationinalargerconditionedspace.
Boththeneedforandlocationoftheremotesensorshouldbedeterminedbyaheating/coolingprofessional.
2.4 Remote Sensor Wiring Instructions1.Routingsignalwires:
Youwillberequiredtosupplyandroute24gauge,4conductorsolidwire(2-linetelephonewire)betweentheDEH3000Rcontrollerandtheremotesensorlocation.•Donotrunwireslongerthan100ft.
•Theuseof24gaugewireisoptimal.Thinnergaugewiremaylimitsensordistance.Thickergaugeswillnotworkwithspliceconnectorsprovided.
•Avoidroutingparalleltohighvoltagewiring.
•Maintainadistanceof2ft.ormorefromhighvoltagelines.
2.Sensorconnection:
Thesensorcanbemountedtoawallorceilingsurface.Idealsensorlocationis5ft.abovethefloor.Wiresshouldexitthrougha½”diameterholeinthemountingsurfaceatthemountinglocation.Usetheprovidedsplice
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
5www.QuestProtect.com
sales@questprotect.com
questquest
connectorstoconnectthe4wiresfromtheremotesensortotheuser-suppliedinterconnectwire.Besuretokeeppropercolorsattachedtoeachother.
3.Sensormounting:
Youwillneedtwoscrewstomountthesensor.Usethetwoslottedholestomountthebaseofthesensortothewallandthensnapthecoverintoplace.
4.Controllerconnection:
Usetheprovidedspliceconnectorstoconnectthe4wiresfromtheDEH3000Rtotheuser-suppliedinterconnectwire.Besuretokeepthepropercolorsattachedtoeachother.
Continuewiththeinstallationasdescribedintherestofthismanual.
2.5 Control Panel Wiring Instructions
WARNING! DO NOT ALLOW THE YELLOW WIRE FROM THE QUEST DEHUMIDIFIER TO CONTACT THE RED OR WHITE WIRES FROM THE QUEST DEHUMIDIFIER, DAMAGE TO THE 24-VOLT TRANSFORMER WILL RESULT.
WARNING! THE QUEST DEH 3000R DIGITAL CONTROL OPERATES ON A LOW VOLTAGE CIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.
WARNING! UNPLUG THE QUEST DEHUMIDIFIER BEFORE WIRING THE DEH 3000R.Theinstallermustsupplyallfieldwiring,includingthewiringbetweentheQUESTdehumidifierandtheQuestDEH3000R.SomeofthecontrolwiresleavingtheQUESTdehumidifiermaynotbeusedinsomecontrolsituationsandshouldbeleftdisconnectedwithwirenutstapedontothestrippedends.
BesuretoconsulttheelectricalschematicinthismanualortheinternalelectricalboxoftheQuestdehumidifierbeforemakinganycontrolconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
questquest1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
6www.QuestProtect.com
sales@questprotect.com
TheWhitewirecontrolstheoptionalmotorizeddamperthatcanbeinstalledintoafreshairduct.ThisdamperprovidestheabilitytocontrolfreshairventilationusingtheventilationtimerfunctionoftheQuestDEH3000Randtheterminallabeled“DMP” (SeeSection3.8).Leavethe“DMP”terminalunusedifamotorizeddamperisnotused,andcapofftheWhitewirefromtheQuestdehumidifier.
Standard wire colors for thermostats are as follows:
Description Color Terminal code
24VAC Red R
CallforHeat White WorW1
ForceFanOn Green G
CompressorCallforCooling Yellow YorY1
2.6 Auxiliary Relay OperationItmaybedesirabletocoordinatefanoperationofthecentralheating/coolingsystemwithdehumidifieroperation.TheQuestDEH3000Rcontainsarelaythatprovidesthisability.
TherelayterminalslabeledNC,COMandNOoperateaccordingtothefollowingchart:
DEHUMIDIFIER COM to NO COM to NC
ON CONNECTED OPEN
OFF OPEN CONNECTED
Commonuses(assumingstandardthermostatwiringcolorsasnoted):
NO
COM
NC
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
7www.QuestProtect.com
sales@questprotect.com
questquest
Lock-out the A/C during dehumidificationThiswillturnofftheA/Cwheneverthedehumidifierruns.
1.WiretheYellowthermostatterminaltotheNCterminalontheQuestDEH3000R.TheinstallermustsupplythewiringbetweentheQuestdehumidifierandthecontrolpanel.Besuretosafelyroutethecontrolwirestopreventdamageduringinstallation.BecarefulnottocrossthewireswhenconnectingtheQuestdehumidifierandtheremotecontrolpanelordamagetothetransformermayresult.
2.RuntheYellowwirefromtheA/CunittotheCOMterminalontheQuestDEH3000R.
Energize the A/C central fan during dehumidificationToautomaticallyruntheA/CFANwhenthedehumidifierruns.1.AttachasecondGreenwiretotheGreenfanwire
terminalonthethermostat.2.ConnectthenewGreenwiretotheCOMterminalonthe
QuestDEH3000R.3.RunawirefromtheRedterminalonthethermostatto
theNO(NormallyOpen)terminalontheQuestDEH3000R.
2.7 Dehumidifier lock-OFF or lock-ON:A/C sensor featureToautomaticallyactivateordeactivatethedehumidifierwhentheairconditionerruns.
Activate dehumidification when the air-conditioner is running.A voltmeter is required for the next steps to ensure the correct wiring from the A/C transformer is used to set up the Lock-in dehumidifier function.
1.ThecommonwirefromtheexistingA/Ctransformer(usuallyBlack)mustbeattachedtothe“COM”sensorterminalbetween“ON-D”and“OFF-D”ontheDEH3000R.
TIP: The common wire can be identified as the wire from the A/C transformer that reads 0 volts between it and the Yellow air conditioning call for cooling wire.The incorrect wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothethermostatYellowterminalandruntothe“ON-D” sensorterminalontheQuestDEH3000R.
A/C Unit
Red
Green
Yellow
A/C Unit
Red
Green
Yellow
A/C Unit
Red
Green
Yellow
A/C Unit
Red
Green
YellowON-D
COM
OFF-D
TO A/C
TO A/C
questquest1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
8www.QuestProtect.com
sales@questprotect.com
Deactivate dehumidification when the air-conditioner is running.AvoltmeterisrequiredforthenextstepstoensurethecorrectwiringfromtheA/CtransformerisusedtosetuptheLock-outdehumidifierfunction.
1. ThecommonwirefromtheexistingA/Ctransformer(usuallyBlack)mustbeattachedtothe“COM”sensorterminalbetween“ON-D”and“OFF-D”ontheDEH3000R.
TIP: The common wire can be identified as the wire from the A/C transformer that reads 0 volts between it and the Yellow air conditioning call for cooling wire. The incorrect wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothethermostatYellowterminalandruntothe“OFF-D”sensorterminalontheDEH3000R.
2.8 TestingVerifythewiringconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
Aftercheckingthewiring,thisshorttestwillconfirmproperhook-up.
1. InstallfrontcoveroftheQuestDEH3000R;connectthetopfirst,thenthebottom.2.PlugintheQUESTdehumidifier.TheQuestDEH3000Rshouldpowerup.3.TurntheQuestDEH3000RONbypressingthe“ON/OFF”button.4.VerifydehumidificationoperationbyadjustingtheRH“SETPOINT”tobelowthe“%RH”
readingonthedisplay.Usethedown“RH”button.ConfirmQuestfanandcompressoroperation.BothshouldbeONnow.
IncreasetheRH“SETPOINT”onthedisplaytowellabovethe“%RH”readingonthedisplay.Pressthe“RH”uparrowtoincreasetheRH“SETPOINT”.
AfterrunningthedehumidifiercompressortheQuestDEH3000Rappliesa10minuterestartlockoutonallfunctions.Youwillhavetowaitfortherestartlockouttoexpire.
5.VerifyFAN-onlyoperation:a.Checkthe“VENT”modeonthedisplay,itwilleitherbe“CLOSED”or“OPEN”.Ifitis“CLOSED”gotothenextstep.Ifitis“OPEN”,pressandholdthe“VENT”keyuntil“OPEN”flashesonthedisplay,releasethekeyandthenpressitonemoretime.“OPEN”willchangeto“CLOSED”.Don’ttouchthekeysforseveralsecondsuntilitstopsflashing.
b.Pressandholdthe“FAN”buttonuntil“AUTO”beginsflashingonthedisplay,releaseit,andthenpressitagaintoswitchthefantothe“ON”setting.
c.ConfirmthattheQUESTfanisON.QuestcompressormustbeOFF.Ventilationdamper(ifused)shouldbeCLOSED.
6.VerifyoptionalVENToperation(ifelectricdamperisinstalled):a.Pressandholdthe“FAN”buttonuntil“ON”flashesonthedisplay.
b.Releasethe“FAN”button,thenpressitagaintoswitchfanoperationto“AUTO”.
TO A/C
TO A/C
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
9www.QuestProtect.com
sales@questprotect.com
questquest
c.Pressandholdthe“VENT”buttonuntil“CLOSED”flashesonthedisplay.
d.Releasethe“VENT”button,thenpressitagaintoswitchventmodeto“OPEN”.
e.ConfirmthattheQuestfanisON.VentilationdamperisOPEN.QUESTcompressormustbeOFF.
f.Pressandholdthe“VENT”buttonuntilthe“OPEN”flashesonthedisplay.
g.Releasethe“VENT”button,thenpressitagaintoswitchventmodeto“CLOSED”.
Troubleshooting:Ifanyfunctionsarenotworkingproperly,checkthewiringandconnections.Avoltmetermaybeusedacrossterminalstoverifyvoltage.Ifthereisconcernaboutthedehumidifiernotoperatingproperly,theleadsexitingtheQUESTdehumidifiermaybeconnectedaccordingtothefollowingchart:
Wire connections Operation
Yellow&Blue Fan&Compressor
Yellow&Green FanOnly
WARNING!DO NOT MAKE ANY OTHER CONNECTIONS OR TRANSFORMER DAMAGE MAY RESULT.
7.VerifyanyadditionaloptionalcontroloperationssuchasfaninterlockorA/Clockout.
8.ProceedtotheOperationsection.
FOR INSTALLER & OWNER:3. OperationOnthedisplayscreen,asolid“O”infrontofanyofthe3functions(SETPOINT,VENT,FAN)indicatesthefunctionisoperating.Aflashing“O”indicatesitisinawaitmodeandnotavailableatthemoment.No“O”indicatesthefunctioniscurrentlyOFF.
Solid“O”before Indicates
SETPOINT Dehumidifieron
VENT Freshairventilationcycleinprogress
FAN Fanon
Waitmodeisafactory-programmedtimeperiodmeanttopreventshortcycles.Thisextendsthelifeofthedehumidifier.Whenaflashing“O”isencountered,theunitisinwaitmodeandIT COULD BE UP TO 10 MINUTES BEFORE OPERATION RESUMES.
3.1 Display•Wheneverthereispowertothecontrol,itwilldisplaythetime,theday,%relativehumidity,andtemperature.
•WhenthecontrolisactuallyswitchedON,the%RHsetpoint,fanstatus,runmode(programorhold),andfreshairventilationstatusisdisplayed.
•Whenakeyispressedthedisplaywilllightforapproximately½aminute.
•TheTimeandDayisdisplayedatthetopofthescreen.
questquest1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
10www.QuestProtect.com
sales@questprotect.com
•RHandTemperaturearedisplayedinrealtime.
•Asolid“O”beforetheSETPOINT,VENT,ORFANindicatesthefunctionisoperating.
•Aflashing“O”beforetheSETPOINT,VENT,ORFANindicatestheunitisinwaitmode.
3.2 SettingDuringtheset-upprocess,ifyoumakeamistake,simplycontinue.Youcanalwaysgobacktoadjustthesettings.Ifyouleavethecontrolaloneanddon’ttouchanybuttonsfor10seconds,thecontrolwillrememberanychangesmadeandreturntothenormaldisplayscreen,allowingyoutoproceedtothenextstep.
3.3 Personal Settings reference listPlease record your settings here.
Function Factory setting My Setting
SETPOINT(%RH) 50%
VENT Closed
FAN Auto
TEMPCUTOUT 99°
3.4 On/Off and display itemsPressthe“ON/OFF”buttontoturnthesystemONorOFF.
WhenthesystemisON,thesetpoint,fanstatus,operationmode(RUNorHOLD),andfreshairventstatusisdisplayed.
WhenthesystemisOFF,thecontrolwilldisplaythetime,day,%RH,andtemperature.
Whentheunitisshipped,itisinmanual(hold)mode.
3.5 Setting Clock Time1.Pressandholdthe“CLOCK”button.Thehourdisplaywillflash.Releasethebutton.
2.Usetheup/down“RH”buttonstochangethevalue.
3.Pressthe“CLOCK”buttonagainandtheminutedisplaywillflash.Usethe“RH”buttonstochangethevalue.
4.Pressthe“CLOCK”buttonagainandAMorPMwillflash.Usethe“RH”buttonstochangethevalue.
5.Pressthe“CLOCK”buttonagainandthedaydisplaywillflash.Usethe“RH”buttonstochangethevalue.
6.Don’ttouchanybuttonsforseveralsecondsuntilthedisplaystopsflashing,thiswillsaveyoursettings.Ifyouneedtochangeanythinggobacktostep#1.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
11www.QuestProtect.com
sales@questprotect.com
questquest
3.6 Adjusting the relative humidity “SETPOINT” TheQuestDEH3000Rsensestheambientrelativehumidity(%RH)ofthespaceinwhichitislocated,itcomesfactorypresettohold50%relativehumidity.
Therelativehumidity“SETPOINT”(desiredRHtobemaintained)operatesthedehumidifierfunctionoftheQuestdehumidifier.IthasnoeffectontheoptionalVENT(freshairventilation)orFAN(airrecirculation)functionsiftheyarebeingused.
OperationThestandardrangethatthedehumidifierholdsaroundyour“SETPOINT”is3%.Withasetpointof50%,thedehumidifierwillrununtiltherelativehumidityreaches47%.Thedehumidifierwillthenswitchoffuntiltherelativehumidityreaches53%.
Ifthesetpointishigherthantheambientrelativehumidity,thespacedoesnotneedtobedehumidifiedsothedehumidifierwillnotrun.
Example:Setpoint:50%RH
Currentcondition:45%RH–Thedehumidifierwillbeoff(no“O”indicatorwillbedisplayed).
Ifyoursetpointisbelowtheambientcondition,thedehumidifierwillbeonand“O”willdisplay.
Example:Setpoint:50%RH
Currentcondition:55%RH–Thedehumidifierwillbeon(“O”displayed).
3.7 Fan Setting and OperationUsethe“FAN”buttontochangethefanoperation.Thereare2choicesforfanoperation:“ON”or“AUTO”.Thefactorypresetis“AUTO”.
“ON”–ThefanintheQuestdehumidifierwillruncontinuously.Thisdoesnotaffecteitherthedehumidificationorventilationfunctionsofthesystem.Thesystemmayormaynotbeventilatingordehumidifyingwhilethefanisrunning.Thissettingiscommonlyusedformaximumairfiltrationand/orairrecirculation.
“AUTO”–IndicatesthefanwillrunwhentheQuestDEH3000Rcallsfordehumidificationorventilation.Ifthecontrolhasnotcalledfordehumidificationfor3hours,thecontrolwillautomaticallyrunthedehumidifierfanfor10minutes.
Afteradehumidificationcycle,thefanautomaticallyshutsofffor10minutes.Thispauseallowsthewatertodrainfromthedehumidifier.
Asolid“O”indicatesthefanisoperating.Aflashing“O”indicatesthefanisinawaitmode.No“O”indicatesthefanisOFF.
Tosettheoperation:1.Pressandholdthe“FAN”button.Thecurrentfansettingwillbegintoflashonthedisplay.Releasethebutton.
2.Pressthe“FAN”buttontotogglebetweenthe“ON”and“AUTO”modes.
Withthefaninthe“AUTO”mode,thefanwilloperateonlywhenneededbyotherfunctionsofthesystem.ThefanwillremainOFFunlessthesystemisdehumidifyingorventilating.Thefanalwaysrunsduringdehumidificationandventilationandthefan“O”iconwillbelit.TocompletelyturnthesystemOFF,usethe“ON/OFF”buttonasdescribedearlier.
questquest1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
12www.QuestProtect.com
sales@questprotect.com
3.8 Damper Operation and Ventilation, Manual (Hold) ModeThe“VENT”settingcontrolstheventilationfunctionofthesystem.Ithasnocontroloverthedehumidificationfunction.Inordertoprovideventilation,themotorizeddampermustbeopenandthefanmustberunning.Thecontrollertakescareofthesetwofunctionsautomaticallysothatwheneverthedamperisopen,thefanisrunning.
Theventilationindicator“O”willbedisplayedwhenevertheunitisventilating.Thefanoperationindicator“O”willalsobelit.
Therearethreedamperoperationmodes:1.“OPEN”–holdmode:Thedamperwillbeopenandthedehumidifierfanwillbecontinuouslyoperatingtointroducefreshairintothespace.Usethismodeforcontinuousfreshairventilation.Thefanisalwaysonwhenthedamperisopen.
2.“CLOSED”–holdmode:Thedamperwillneveropen,andthedehumidifierwillnotventilate.Thefanwillstilloperatenormallyforrecirculationanddehumidification.
3.“PROGRAMMED”mode:TheQuestDEH3000Rwilloperatethemotorizeddamperandthedehumidifierfanaccordingtotheprogrammedventilationschedule(Section3.9).
Thefactorypresetforthe“VENT”settingis“CLOSED”.
Toset“OPEN”–holdor“CLOSED”–holdventilationoperation:1.Pressthe“VENT”button.Thecurrentsettingwillbegintoflashonthedisplay.Releasethebutton.
2.Pressthe“VENT”buttonagaintoswitchbetween“OPEN”and“CLOSED”.
3.Leavethecontrolalonefor10secondsandyoursettingswillbesaved.
Damper Operation and Ventilation, Programmed VentilationThisexampleshowsthesysteminprogrammode(denotedbytheschedule15minuteson,5minutesoffandthewordRUNinthelowerrightcornerofthedisplay).
TheQuestDEH3000Rwilloperatefreshairventilationaccordingtoyourventilationprogram.ThecontrolneedstobeprogrammedtoturntheventilationfunctionONandOFFatthedesiredintervals.Thisisdonebyprogrammingtheventilationtimer.
Therearetwoprogramsavailableforventilation:1.MondaythroughSunday
2.MondaythroughFriday&Saturday/Sunday
Eachblockofdayshasamorningscheduleandanightschedule.Morningisthefirst12hoursofthedayandnightisthesecond12hours.
Eachschedulehas:
•A“START”timewhentheventilationschedulebegins,
•An“OPEN FOR”durationfortheamountoftimethedamperstaysopenin5minuteintervals,from0to60,
•And“CLOSED FOR”durationwhichclosesthedamperforaspecifiedtimein5minuteintervalsfrom0to60.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
13www.QuestProtect.com
sales@questprotect.com
questquest
Setting the Ventilation Program:
1.Pressthe“PROGRAM ENTER”buttonuntilthefollowingmenuappears:
2.Usingtheup/down“RH”buttons,highlight“PROGRAM”andselectitbypressingthe“PROGRAM ENTER”button.Thefollowingmenuappears:
Youcanselectfrom:“MON-FRI”“SAT-SUN”forseparateweekdayandweekendschedules,or“MON-SUN”whichgivesyouequalweekdayandweekendschedules.
3.UsingtheUp/Down“RH”buttons,highlightandthenselectoneofthetwochoices.Theexamplegivenshowshowtoprogramseparateweekdayandweekendschedules.Thesamemethodisusedifyouchoosetheotherprogram.
Example:menuwhenyouselect“MON-FRI”“SAT-SUN”:
1.Enterthestartingtimeforweekdaysusingtheup/down“RH”buttonstochangethetime.
2.Pressthe“PROGRAM ENTER”buttontoswitchtothe“OPEN FOR”setting.Usingtheup/down“RH”buttons,changethedurationthatthedamperwillventilatefreshair.
3.Pressthe“PROGRAMENTER”buttontoswitchtothe“CLOSEDFOR”setting.Usingtheup/down“RH”buttons,changethedurationthatthedamperwillremainclosedbetweenventilationcycles.
Fortheexamplegiven,startingat8:00AMinthemorning,thecontrolwillventilatefreshairfor15minutesthenstopfor15minutes.Thisscheduleof15minutesopen,15minutesclosedwillcontinueuntilthestarttimeofthenightschedule.
Morningscheduleisavailableanytimefrom12:00AMuntil11:59AM.
Nightscheduleisavailableanytimefrom12:00PMuntil11:59PM.
4.Press“PROGRAMENTER”againtogotothe“MON-FRI”nightschedule.Repeatthestepslistedaboveforthisandthe“SAT-SUN”dayandnightschedules.
questquest1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
14www.QuestProtect.com
sales@questprotect.com
Whenyouhavefinishedprogrammingyourschedule(eitherthe7-dayversionortheweekday/weekendsplitversion),usethedown“RH”buttontohighlighttheEXIToptionandthenpress“PROGRAM ENTER”toselectit.
RunningtheVentilationProgram
Pressandholdthe“PROGRAM ENTER”buttonuntilthe“PROGRAM”screenappears.
Usethedown“RH”buttontohighlight“RUN PROGRAM”:
Thenpress“PROGRAMENTER”toselectit.Thedisplaywillappearasfollows:
3.9 Temperature Cutout ProgrammingDehumidifiersproduceheatwhendehumidifyinganddependinguponoutsideconditions,theventilationfunctionmayalsointroducewarmair.Someconditionsmayintroduceenoughheattodrivetemperaturesup.TheQuestDEH3000RtemperaturecutoutfeaturedisablesallQuestoperationsiftemperaturesreachthecutoutsetpoint.
Inmostinstallationsthisfeaturewillnotneedtobeused(thecutoutisfactorysetto99°F).Ifalowertemperaturecutoutisdesired,programthesetpointbypressingandholdingthe“PROGRAMENTER”buttonuntilthe“PROGRAM”screenappears.Presstheup/down“RH”buttonsuntil“TEMPCUTOUT”highlighted.Thenpressthe“PROGRAMENTER”buttonagaintoselectit.Nowusethe“RH”upor“RH”downbuttonstoadjustthesetpoint.Press“PROGRAMENTER”toreturntothehomescreen.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
15www.QuestProtect.com
sales@questprotect.com
questquest
WARRANTOR: Therma-StorLLC4201LienRdMadison,WI53704Telephone:1-800-533-7533
WHO IS COVERED: Thiswarrantyextendsonly to theoriginalresidentialend-userof theQuestDEH3000RDehumidifier&VentilationSystemController,andmaynotbeassignedortransferred.
FIRST YEAR WARRANTY: Therma-StorLLCwarrantsthat,forone(1)yeartheQuestDEH3000RDehumidifier&VentilationSystemControllerwilloperatefreefromanydefects inmaterialsandworkmanship,orTherma-StorLLCwill,atitsoption,repairorreplacethedefectivepart(s),freeofanycharge.
END-USER RESPONSIBILITIES:WarrantyservicemustbeperformedbyaServicerauthorizedbyTherma-StorLLC.Iftheend-userisunabletolocateorobtainwarrantyservicefromanauthorizedServicer,heshouldcallTherma-StorLLC at theabovenumberandask for theTherma-StorLLCServiceDepartment,whichwillthenarrangeforcoveredwarrantyservice.Warrantyservicewillbeperformedduringnormalworkinghours.
TheEnd-usermustpresentproofofpurchase(lease)uponrequest,byuseofthewarrantycardorotherreasonableandreliablemeans.Theend-userisresponsiblefornormalcare.Thiswarrantyonlyappliestoresidentialapplicationsanddoesnotcoveranydefect,malfunction,etc.resultingfrommisuse,abuse,lackofnormalcare,corrosion,freezing,tampering,modification,unauthorizedorimproperrepairorinstallation,accident,actsofnatureoranyothercausebeyondTherma-StorLLC'sreasonablecontrol.
LIMITATIONS AND EXCLUSIONS:IfanyQuestDEH3000RDehumidifier&VentilationSystemControllerpartisrepairedorreplaced,thenewpartshallbewarrantedforonlytheremainderoftheoriginalwarrantyperiodapplicablethereto(butallwarrantyperiodswillbeextendedbytheperiodoftime,ifany,thattheQuestDEH3000RDehumidifier&VentilationSystemControllerisoutofservicewhileawaitingcoveredwarrantyservice).
UPONTHEEXPIRATIONOFTHEWRITTENWARRANTYAPPLICABLETOTHEQuestDEH3000RDehumidifier&VentilationSystemControllerORANYPARTTHEREOF,ALLOTHERWARRANTIESIMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULARPURPOSE, SHALLALSO EXPIRE. ALLWARRANTIESMADEBYTHERMA-STOR LLC ARE SETFORTHHEREIN,ANDNOCLAIMMAYBEMADEAGAINSTTHERMA-STORLLCBASEDONANYORALWARRANTY. INNO EVENT SHALLTHERMA-STOR LLC, IN CONNECTIONWITHTHESALE,INSTALLATION,USE,REPAIRORREPLACEMENTOFANYQuestDEH3000RDehumidifier&VentilationSystemControllerORPARTTHEREOFBELIABLEUNDERANYLEGALTHEORYFORANYSPECIAL,INDIRECTORCONSEQUENTIALDAMAGESINCLUDINGWITHOUTLIMITATIONWATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOSTPROFITS,DELAY,ORLOSSOFUSEORDAMAGETOANYREALORPERSONALPROPERTY.
Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,andsomedonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sooneorbothoftheselimitationmaynotapplytoyou.
LEGAL RIGHTS: Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.
Recommended