Dear Sentry Building Owner, We would like to take this opportunity to thank you for purchasing a SIOUX STEEL PRO-TEC BUILDING . We believe that it will serve you well for many years. The framework uses quality certified structural grade steel tubing. All welded rafter assemblies are powder coated or hot-dipped galvanized to provide maximum corrosion protection. We believe in providing QUALITY, RELIABILITY, DURABILITY, VERSATILITY , and COMMITMENT to meet the needs of our customer. Should you have any questions or comments during or following the installation, please feel free to call your SIOUX STEEL PRO-TEC BUILDING dealer or manufacturer. We will be glad to assist you in any way we can.
IMPORTANT Improper Site Preparation, Assembly and Maintenance may invalidate warranty and cause unnecessary and costly mistakes.
READ MANUAL FIRST
If you have any questions contact Sioux Steel Co. at 1-800-557-4689
Procedure For Viewing Sentry Manuals On-Line: • Log on to siouxsteel.com.
• Select Dealer Login in upper right hand corner.
• Enter Username, Password and select Submit.
If you don’t have a username and password, contact your dealer or
Sioux Steel Company Customer Service at 1-800-557-4689.
• Select the Engineering Manuals folder in the center of the screen.
• Select the ProTec Manuals folder.
• Select the Sentry folder.
• Based on manual description select the desired manual you wish to open, view
and/or print.
• A second tab will open up with a PDF file of the desired manual.
• If you wish to print the manual, select the printer icon in the upper left hand
corner.
GENERAL INFORMATION
Foundation for Sentry Building: In all cases, the soil and foundation must be sufficiently stable and deemed suitable to support the forces produced by the structure. It is recommended that the customer consult a quali fied engineer to certify the soil conditions and foundat ion design for their location. Soil and foundation must be able to withstand forces which meet or exceed the structural forces. Contact Sioux Steel Company or your dealer for building specific structural forces. Site Conditions for Sentry Building: The installation site must be sufficiently level to permit uniform wall assembly on a support foundation. In all cases, the area surrounding the Sentry Building must provide sufficient drainage to prevent soil erosion around the foundation. The structure has been designed to meet 90 mph exposure C wind load and 30, 40, and 50 psf (16', 12', & 10' rafter spacing respectively) ground snow load , for open terrain with obstructions having heights generally less than 30 feet. This terrain must extend upwind for a distance greater than 2600 feet. The building must be positioned at least 20 feet away from existing structures with a higher eave to prevent excessive load from drifting snow. Contact your insurance agent prior to assembly to i nsure you are covered in case of inadvertent accidents that may occur during erectio n. NOTE: Sioux Steel Company is not responsible o r liable for:
- Any damage or failure that may occur due to i ncorrect erection of building. - Any soil analysis or foundation design, - Substitution of components not specified in t he construction manual that lead to damage or failure. - Unstable soil conditions or foundation that l ead to structure damage or failure. - Damage caused by leaning sidewalls . - Any modification of design or structure. - Any bodily injury that occurs during the asse mbly of the building or as a result of modification to the design or impr oper construction. - Caustic or corrosive environments that lead t o structure deterioration, damage or failure. - See warranty in structure manual.
REF - RAFTER TUBE
7
3
4
5
8
3
3
3
2
4
6
6
REF - POST
1
AWNING FRAME PARTS LISTING36' PW SINGLE TUBE BUILDING
ITEM NUMBER DESCRIPTION QTY
1 179947GRY AWNING END TUBE, LH 1
2 179948GRY AWNING END TUBE, RH 1
3 179720GRY AWNING CENTER TUBE VAR
4 179758GRY EAVE SWAGED END TUBE 2
5 172328GRY EAVE DOUBLE SLIP TUBE 1
6 172329GRY EAVE SINGLE SLIP TUBE VAR
7 177962GRY LOWER TUBE VAR
8 177964GRY LOWER BRACE TUBE VAR
2
172329GRYEAVE- SINGLE SLIP TUBE
179947GRYEND TUBE, LH
177964GRYLOWER BRACE
AWNING COMPONENTS36' PONY WALL SINGLE TUBE BUILDING
179948GRYEND TUBE, RH
179758GRYEAVE- SWAGED END TUBE
177962GRYLOWER TUBE
179720GRYCENTER TUBE
172328GRYEAVE- DOUBLE SLIP TUBE
3
154029BOLT, 3/8" X 3-1/2"
AWNING COMPONENTS36' PONY WALL SINGLE TUBE BUILDING
169706BOLT, 3/8" X 1-1/2"
154051HEX NUT, 3/8"
167834LAGSCREW, 5/16" X 3"
187299DRILL SCREW, 1/4" X 3/4"
4
27-1/2
these holesshown and alignPosition parts as
Use (8) 5/16 x 3 lag boltsat each post
27-1/2
Use (8) 5/16 x 3 lag boltsat each post
Position parts asshown and alignthese holes
Right End Post Detail
Left End Post Detail
Center Post Detail
Attach the 177962GRY Lower Tubes to posts as shown below using (4) 167834 5/16 x 3 lag bolts.Note the brace positions for each post location.
Attach the 177964GRY Lower Braces to the posts by aligning the single hole with thelower tube and attching its mount plate to the posts using (4) 167834 5/16 x 3 lag bolts.
INSTALLATION OF BRACE TUBES36' PONY WALL SINGLE TUBE BUILDING
27-1/2
these holesshown and alignPosition partsas
Use (8) 5/16 x 3 lag boltsat each post
5
frame members
10' Center toCenter for awning
Install the Lower Tubes and Lower Braces on every other post per the diagramson the preceeding page. The spacing of the Awning frame members is 10' on centers.
BRACE TUBE INSTALLATIONOVERALL VIEW
36' PONY WALL SINGLE TUBE BUILDING
6
179947GRY
179948GRY
are installed
Leave this connectionloose untill the slide tubes
179720GRY
Attach 179947GRY End Tube, LH to the Brace Tubes using 3/8 x 1-1/2 bolts and nuts.Attach the other end to the rafter tubes by drilling a 7/16 dia hole (use the Awning tube bracketas a guide) and secure with 3/8 x 3-1/2 bolts and nuts.
Attach 179720GRY Center Tubes to the Brace Tubes using 3/8 x 1-1/2 bolts and nuts.Attach the other end to the rafter tubes by drilling a 7/16 dia hole (use the Awning tube bracketas a guide) and secure with 3/8 x 3-1/2 bolts and nuts.
Attach 179948GRY End Tube, RH to the Brace Tubes using 3/8 x 1-1/2 bolts and nuts.Attach the other end to the rafter tubes by drilling a 7/16 dia hole (use the Awning tube bracketas a guide) and secure with 3/8 x 3-1/2 bolts and nuts.After this End Tube is attached to the rafter tube, remove the bolt from the brace connectionuntill the Eave Swaged End Tube has been installed.
MAIN AWNING TUBES INSTALLATION36' PONY WALL SINGLE TUBE BUILDING
Secure the End Tubes, Lower Tubes, and Lower Braces with 3/8 x 1-1/2 boltsand nuts.
at the second hole.
Preferred
Drill a 7/16 hole throughthe rafter tube and securewith 3/8 x 3-1/2 bolts andnuts.
An alternate method would be tosecure with 3/8 x 3-1/2 bolts and nuts
Alternate
7
Install one end of 179758GRY Eave- Swaged Slip Tube into the 179947GRY Awning End Tube, LH.The opposite end slides into 172328GRY Eave- Double Slip Tube. Slide the bungs of the DoubleSlip Tubes into 179720GRY Awning Center Tubes. These parts are held in place with 187299 1/4 x 3/4 Drill Screws. Make sure to install the drill screws from the lower side of Awning tubes tokeep their heads away from the building cover.
Next slide 172329GRY Eave- Single Slip Tubes into the remaining Eave Tubes and the remaining Awning Center Tubes and secure with the Drill Screws as before.
The last section is completed by inserting another 179758GRY Eave- Swaged Slip Tube betweenthe final Eave- Single Slip Tube and 179948 Awning End Tube, RH. Reinstall the 3/8 x 1-1/2 boltand nut at the last Brace Tubes and secure the last Slip Tube with Drill Screws as before.
AWNING SLIP TUBE INSTALLATION36' PONY WALL SINGLE TUBE BUILDING
172329GRY
179947GRY
Installed Last
179948GRY
179758GRY
179758GRY
after last Slip Tube is installed.
172328GRY
172329GRY
Reinstall this 3/8 x 1-1/2 bolt and nut
179720GRY
8
AWNING PACKAGES - CURVED ENDS
LENGTH 36' SINGLE TUBE BLDGS 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260
PART # 179759-(LENGTH) X X X X X X X X X X
PART # DESCRIPTION QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY
179947GRY AWNING END TUBE LH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179948GRY AWNING END TUBE RH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179720GRY UPPER AWNING CORD 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
177962GRY LOWER TUBE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
177964GRY LOWER BRACE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
172328GRY DOUBLE SLIP TUBE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
172329GRY SINGLE SLIP TUBE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
179758GRY END SWAGED TUBE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
154029 3/8"x3.5" BOLT 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
169706 3/8"x1.5" BOLT 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
154051 3/8" NUT 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55
187299 1/4"x3/4" DRILL SCREW 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53
167834 5/16" x 3" LAG SCREWS 33 42 50 58 66 75 83 91 99 108 116 124 132 141 149 157 165 174 182 190 198 206 215 223
167642 2 GALLON PAIL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
167644 2/4 GALLON LID 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
173803 DECAL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
9
10
4
REF - POST
1
3
3
3
3
7
8
4
5
6
6
REF - RAFTER
AWNING FRAME PARTS LISTING36' PONY WALL TRUSS BUILDING
ITEM NUMBER DESCRIPTION QTY
1 179947GRY AWNING END TUBE, LH 1
2 179948GRY AWNING END TUBE, RH 1
3 179720GRY AWNING CENTER TUBE VAR
4 179758GRY END SWAGED TUBE 2
5 172328GRY DOUBLE SLIP TUBE 1
6 172329GRY SINGLE SLIP TUBE VAR
7 177962GRY LOWER TUBE VAR
8 177964GRY LOWER BRACE TUBE VAR
11
172328GRYEAVE- DOUBLE SLIP TUBE
180816GRYAWNING CENTER TUBE
172329GRYEAVE- SINGLE SLIP TUBE
177962GRYLOWER TUBE
179948GRYAWNING END TUBE, RH
179758GRYEAVE- SWAGED END TUBE
AWNING COMPONENTS36' PONY WALL TRUSS BUILDING
177964GRYLOWER BRACE
179947GRYAWNING END TUBE, LH
12
154051HEX NUT, 3/8"
167834LAGSCREW, 5/16" X 3"
187299DRILL SCREW, 1/4" X 3/4"
154025BOLT, 3/8" X 2-1/2"
154029BOLT, 3/8" X 3-1/2"
AWNING COMPONENTS36' PONY WALL TRUSS BUILDING
169706BOLT, 3/8" X 1-1/2"
13
Left End Post Detail
Attach the 177964GRY Lower Braces to the posts by aligning the single hole with the
Note the brace positions for each post location.
lower tube and attching its mount plate to the posts using (4) 167834 5/16 x 3 lag bolts.
Right End Post Detail
Center Post Detail
Attach the 177962GRY Lower Tubes to posts as shown below using (4) 167834 5/16 x 3 lag bolts.
INSTALLATION OF BRACE TUBES36' PONY WALL TRUSS BUILDING
27-1/2 shown and alignthese holes
Position partsas
Use (8) 5/16 x 3 lag boltsat each post
27-1/2
these holesshown and alignPosition parts as
Use (8) 5/16 x 3 lag boltsat each post
27-1/2
at each postUse (8) 5/16 x 3 lag bolts
Position parts asshown and alignthese holes
14
BRACE TUBE INSTALLATIONOVERALL VIEW
36' PONY WALL TRUSS BUILDING
Install the Lower Tubes and Lower Braces on every other post per the diagramson the preceeding page. The spacing of the Awning frame members is 10' on centers.
frame members
10' Center toCenter for awning
15
At the Center Tubes,drill a 7/16 hole throughthe Rafter Tube and securewith 3/8 x 2-1/2 bolts andnuts.
179947GRY
180816GRY
1179948GRY
Leave this connectionloose untill the slide tubesare installed.
Attach 179947GRY End Tube, LH to the Brace Tubes using 3/8 x 1-1/2 bolts and nuts.Attach the other end to the rafter tubes by drilling a 7/16 dia hole (use the Awning tube bracketas a guide) and secure with 3/8 x 3-1/2 bolts and nuts.
Attach 180816GRY Center Tubes to the Brace Tubes using 3/8 x 1-1/2 bolts and nuts.Attach the other end to the rafter tubes by drilling a 7/16 dia hole (use the Awning tube bracketas a guide) and secure with 3/8 x 2-1/2 bolts and nuts.
Attach 179948GRY End Tube, RH to the Brace Tubes using 3/8 x 1-1/2 bolts and nuts.Attach the other end to the rafter tubes by drilling a 7/16 dia hole (use the Awning tube bracketas a guide) and secure with 3/8 x 3-1/2 bolts and nuts.After this End Tube is attached to the rafter tube, remove the bolt from the brace connectionuntill the Eave Swaged End Tube has been installed.
MAIN AWNING TUBES INSTALLATION36' PONY WALL TRUSS BUILDING
Secure the End Tubes, Lower Tubes,and Lower Braces with 3/8 x 1-1/2 boltsand nuts.
At the End Tubes (LH & RH),drill a 7/16 hole throughthe Rafter Tube and securewith 3/8 x 3-1/2 bolts andnuts.
16
Install one end of 179758GRY Eave- Swaged Slip Tube into the 179947GRY Awning End Tube, LH.The opposite end slides into 172328GRY Eave- Double Slip Tube. Slide the bungs of the DoubleSlip Tubes into 180816GRY Awning Center Tubes. These parts are held in place with 187299 1/4 x 3/4 Drill Screws. Make sure to install the drill screws from the lower side of Awning tubes tokeep their heads away from the building cover.
Next slide 172329GRY Eave- Single Slip Tubes into the remaining Eave Tubes and the remaining Awning Center Tubes and secure with the Drill Screws as before.
The last section is completed by inserting another 179758GRY Eave- Swaged Slip Tube betweenthe final Eave- Single Slip Tube and 179948GRY Awning End Tube, RH. Reinstall the 3/8 x 1-1/2 boltand nut at the last Brace Tubes and secure the last Slip Tube with Drill Screws as before.
AWNING SLIP TUBE INSTALLATION36' PONY WALL TRUSS BUILDING
172328GRY
172329GRY172329GRY
179948GRY
179758GRY
Installed Last
179947GRY
179758GRY
180816GRY
Reinstall this 3/8 x 1-1/2 bolt and nutafter last Slip Tube is installed.
17
AWNING PACKAGES - CURVED ENDS
LENGTH 36'PW TRUSS BLDGS 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260
PART # 180827-(LENGTH) X X X X X X X X X X X X X X X X X X X X X X X X
PART # DESCRIPTION QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY
179947GRY AWNING END TUBE LH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179948GRY AWNING END TUBE RH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
180816GRY UPPER AWNING CORD 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
177962GRY LOWER TUBE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
177964GRY LOWER BRACE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
172328GRY DOUBLE SLIP TUBE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
172329GRY SINGLE SLIP TUBE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
179758GRY END SWAGED TUBE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
154025 3/8"x2.5" BOLT 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
154029 3/8"x3.5" BOLT 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
169706 3/8"x1.5" BOLT 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
154051 3/8" NUT 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55
187299 1/4"x3/4" DRILL SCREW 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53
167834 5/16" x 3" LAG SCREWS 33 42 50 58 66 75 83 91 99 108 116 124 132 141 149 157 165 174 182 190 198 206 215 223
167642 2 GALLON PAIL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
167644 2/4 GALLON LID 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
173803 DECAL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
18
19
AWNING FRAME PARTS LISTING42', 56', 64', 70' PONY WALL BUILDING
9
7
REF - RAFTER
REF - POST
1
3
3
3
3
2
4
5
6
6
4
7
7
7
7
8
7
ITEM NUMBER DESCRIPTION QTY
1 179947GRY AWNING END TUBE, LH 1
2 179948GRY AWNING END TUBE, RH 1
3 179720GRY AWNING CENTER TUBE VAR
4 179758GRY END SWAGED TUBE 2
5 172328GRY DOUBLE SLIP TUBE 1
6 172329GRY SINGLE SLIP TUBE VAR
7 172320GRY LOWER BRACE TUBE VAR
8 161125 STRAIGHT TIE DOWN TUBE VAR
9 160972 SWAGED TIE DOWN TUBE VAR
20
172328GRYEAVE- DOUBLE SLIP TUBE
179758GRYEAVE- SWAGED END TUBE
172320GRYLOWER BRACE TUBE
160972SWAGED TIE DOWN TUBE
161125STRAIGHT TIE DOWN TUBE
172329GRYEAVE- SINGLE SLIP TUBE
179948GRYEND TUBE, RH
179947GRYEND TUBE, LH
AWNING COMPONENTS42', 56', 64'. 70' PONY WALL BUILDING
179720GRYCENTER TUBE
21
154051HEX NUT, 3/8"
167834LAGSCREW, 5/16" X 3"
187299DRILL SCREW, 1/4" X 3/4"
170052PLUG
154019BOLT, 3/8" X 1"
AWNING COMPONENTS42', 56', 64', 70' PONY WALL BUILDING
184651 - WINCH STRAP, 1" X 10'178169 - WINCH STRAP, 2" X 15'
161754 - RATCHET, 1"
154029BOLT, 3/8" X 3-1/2"
22
Secure End Tubes and CenterTubes with 3/8 x 1 bolts and nuts.
Attach the 172320GRY Lower Mount Tubes to each Corner by drilling a 7/16 hole and installing 3/8 x 3-1/2 bolts and nuts.Attach the Lower Mount Tubes to each 179947GRY, 179948GRY, and 179720GRY AwningTubes with 3/8 x 1 bolts and nuts.Attach the other end of the Awning Tubes to each Rafter by drilling a 7/16 hole in theRafter tubes and secure with 3/8 x 3-1/2 bolts and nuts.After the last Awning Tube is attached to the Rafter, remove the 3/8 x 1 bolt from theend connection until the Awning Slip Tubes are installed per the next step.
MAIN AWNING TUBES INSTALLATION42', 56', 64', 70' PONY WALL BUILDING
Drill a 7/16 hole through the MountTube and secure with a 3/8 x 3-1/2 boltand nut.
179948GRY
179947GRY
installed.
Leave this connection looseuntil the slide tubes are
179720GRY
Drill a 7/16 hole through theRafter Tube and secure witha 3/8 x 3-1/2 bolt and nut.
23
AWNING SLIP TUBE INSTALLATION42', 56', 64', 70' PONY WALL BUILDING
Install one end of 179758GRY Eave Swaged Slip Tube into the 179947GRY Awning End Tube, LH.The opposite end slides into 172328GRY Eave Double Slip Tube. Slide the bungs of the DoubleSlip Tubes into 179720GRY Awning Center Tubes. These parts are held in place with 1782991/4 x 3/4 Drill Screws. Make sure to install the drill screws from the lower side of Awning tubes tokeep their heads away from the building cover.
Next slide 172329GRY Eave Single Slip Tubes into the remaining Eave Tubes and the remainingAwning Center Tubes and secure with the Drill Screws as before.
The last section is completed by inserting another 179758GRY Eave Swaged Slip Tube betweenthe final Eave Single Slip Tube and 179948GRy Awning End Tube, RH. Reinstall the 3/8 x 1 boltand nut at the last Brace Tube and secure the last Slip Tube with Drill Screws as before.
179947GRY
179720GRY
179758GRY
172328GRY
172329GRY
Installed Last
172329GRY
179758GRY
after last Slip Tube is installed.Reinstall this 3/8 x 1 bolt and nut
179948GRY
24
AWNING PACKAGES - CURVED ENDS
LENGTH 42'/56'/64'/70' PW BLDGS 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260
PART # 179760-(LENGTH) X X X
PART # DESCRIPTION QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY
179947GRY AWNING END TUBE LH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179948GRY AWNING END TUBE RH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179720GRY UPPER AWNING CORD 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
172320GRY LOWER TUBE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
172328GRY DOUBLE SLIP TUBE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
172329GRY SINGLE SLIP TUBE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
179758GRY END SWAGED TUBE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
161125 1.29 x 122" TIE DOWN 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
160972 1.29" x 10' SWAGE TUBE 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
154029 3/8"x3.5" BOLT 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55
154019 3/8"x1.0" BOLT 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
154051 3/8" NUT 13 16 19 22 25 28 31 34 37 40 43 46 49 52 55 58 61 64 67 70 73 76 79 82
187299 1/4"x3/4" DRILL SCREW 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53
161754 RATCHET 1'' W/HANDLE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
184651 STRAP- 1'' X 10FT GREY 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
167642 2 GALLON PAIL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
167644 2/4 GALLON LID 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
173803 DECAL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
170052 1.29" PLUG 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
178169 2" X 15' TIE DOWN STRAP 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
25
26
7
3
7
7
7
1
3
3
2
4
4
7
6
6
5
37
REF - RAFTER
REF - LEG
AWNING FRAME PARTS LISTING42', 56' TRUSS WALL BUILDING
ITEM NUMBER DESCRIPTION QTY
1 179947GRY AWNING END TUBE, LH 1
2 179948GRY AWNING END TUBE, RH 1
3 179720GRY AWNING CENTER TUBE VAR
4 179758GRY END SWAGED TUBE 2
5 172328GRY DOUBLE SLIP TUBE 1
6 172329GRY SINGLE SLIP TUBE VAR
7 172320GRY LOWER BRACE TUBE VAR
27
172328GRYEAVE- DOUBLE SLIP TUBE
179720GRYCENTER TUBE
179948GRYEND TUBE, RH
AWNING COMPONENTS42', 56' TRUSS WALL BUILDING
179758GRYEAVE- SWAGED END TUBE
179947GRYEND TUBE, LH
172329GRYEAVE- SINGLE SLIP TUBE
172320GRYLOWER BRACE TUBE
28
187299DRILL SCREW, 1/4" X 3/4"
161754 - RATCHET, 1"
154051HEX NUT, 3/8"
154029BOLT, 3/8" X 3-1/2"
167834LAGSCREW, 5/16" X 3"
154019BOLT, 3/8" X 1"
42', 56 TRUSS WALL BUILDINGAWNING COMPONENTS
184651 - WINCH STRAP, 1" X 10'178169 - WINCH STRAP, 2" X 15'
29
179948GRY
179947GRY
179720GRY
Leave this connectionloose until the slidetubes are installed.
42', 56' TRUSS WALL BUILDINGMAIN AWNING TUBES INSTALLATION
Attach the 172320GRY Lower Mount Tubes to each Corner outer tube by drilling a 7/16 holeand secure with 3/8 x 3-1/2 bolts and nuts.Attach the Lower Mount Tubes to each 179947GRY, 179948GRY, and 179720GRY AwningTubes with 3/8 x 1 bolts and nuts.Attach the other end of the Awning Tubes to each Rafter upper tube by drilling a 7/16 holeand secure with 3/8 x 3-1/2 bolts and nuts.After the last Awning Tube is attached to the Rafter, remove the 3/8 x 1 bolt from the end connection until the Awning Slip Tubes are installed per the next step.
Secure End Tubes and CenterTubes to Lower Braces with 3/8 x 1 bolts and nuts.
with a 3/8 x 3-1/2 bolt and nut.
Drill a 7/16 hole through theCorner outer tube and secure
172320GRY
Drill a 7/16 hole throuighthe Rafter upper tube andsecure with a 3/8 x 3-1/2bolt and nut.
30
172328GRY
172329GRY172329GRY
179947GRY
179720GRY
179720GRY
179720GRY
179720GRY
179948GRY
179758GRY
179758GRY
AWNING SLIP TUBE INSTALLATION42', 56' TRUSS WALL BUILDING
Install one end of 179758GRY Eave Swaged Slip Tube into the 179947GRY Awning End Tube, LH.The opposite end slides into 172328GRY Eave Double Slip Tube. Slide the bungs of the DoubleSlip Tubes into 179720GRY Awning Center Tubes. These parts are held in place with 1782991/4 x 3/4 Drill Screws. Make sure to install the drill screws from the lower side of Awning tubes tokeep their heads away from the building cover.
Next slide 172329GRY Eave Single Slip Tubes into the remaining Eave Tubes and the remainingAwning Center Tubes and secure with the Drill Screws as before.
The last section is completed by inserting another 179758GRY Eave Swaged Slip Tube betweenthe final Eave Single Slip Tube and 179948GRY Awning End Tube, RH. Reinstall the 3/8 x 1 boltand nut at the last Brace Tube and secure the last Slip Tube with Drill Screws as before.
31
AWNING PACKAGES - CURVED ENDS
LENGTH 42'/56' TW BLDGS 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260
PART # 180825-(LENGTH)
PART # DESCRIPTION QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY
179947GRY AWNING END TUBE LH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179948GRY AWNING END TUBE RH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179720GRY UPPER AWNING CORD 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
172320GRY LOWER TUBE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
172328GRY DOUBLE SLIP TUBE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
172329GRY SINGLE SLIP TUBE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
179758GRY END SWAGED TUBE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
154029 3/8"x3.5" BOLT 9 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54
154019 3/8"x1.0" BOLT 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
154051 3/8" NUT 13 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 69 72 75 78 81
187299 1/4"x3/4" DRILL SCREW 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53
161754 RATCHET 1'' W/HANDLE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
184651 STRAP- 1'' X 10FT GREY 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
167642 2 GALLON PAIL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
167644 2/4 GALLON LID 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
173803 DECAL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
178169 2" X 15' TIE DOWN STRAP 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
32
33
REF - LEG
8
AWNING FRAME PARTS LISTING64', 70' TRUSS WALL BUILDING
1
2
3
3
3
3
4
5
6
6
4
7
7
7
7
7
REF - RAFTER
9
ITEM NUMBER DESCRIPTION QTY
1 179947GRY AWNING END TUBE, LH 1
2 179948GRY AWNING END TUBE, RH 1
3 179720GRY AWNING CENTER TUBE VAR
4 179758GRY END SWAGED TUBE 2
5 172328GRY DOUBLE SLIP TUBE 1
6 172329GRY SINGLE SLIP TUBE VAR
7 180645GRY LOWER BRACE TUBE VAR
8 161125 STRAIGHT TIE DOWN TUBE VAR
9 160972 SWAGED TIE DOWN TUBE VAR
34
179948GRYEND TUBE, RH
172329GRYEAVE- SINGLE SLIP TUBE
179720GRYCENTER TUBE
160972SWAGED TIE DOWN TUBE
179947GRYEND TUBE, LH
AWNING COMPONENTS64', 70' TRUSS WALL BUILDING
179758GRYEAVE- SWAGED END TUBE
161125STRAIGHT TIE DOWN TUBE
180645GRYLOWER BRACE TUBE172328GRY
EAVE- DOUBLE SLIP TUBE
35
AWNING COMPONENTS64', 70' TRUSS WALL BUILDING
184651 - WINCH STRAP, 1" X 10'178838 - WINCH STRAP, 2" X 28'
170052PLUG
154019BOLT, 3/8" X 1"
167834LAGSCREW, 5/16" X 3"
154029BOLT, 3/8" X 3-1/2"
187299DRILL SCREW, 1/4" X 3/4"
154051HEX NUT, 3/8"
161754 - RATCHET, 1"
36
Secure End Tubes and CenterTubes to Lower Braces with3/8 x 1 bolts and nuts.
a 3/8 x 3-1/2 bolt and nut.
Drill a 7/16 hole through theRafter tube and secure with
180645GRY
179948GRY
179720GRY
are installed.
Leave this connectionloose until the slide tubes
179947GRY
Drill a 7/16 hole through theRafter upper tube and secure with a 3/8 x 3-1/2 boltand nut.
Attach the 180645GRY Lower Mount Tubes to each Rafter upper tube by drilling a 7/16 holeand secure with 3/8 x 3-1/2 bolts and nuts.Attach the Lower Mount Tubes to each 179947GRY, 179948GRY, and 179720GRY AwningTubes with 3/8 x 1 bolts and nuts.Attach the other end of the Awning Tubes to each Rafter upper tube by drilling a 7/16 holeand secure with 3/8 x 3-1/2 bolts and nuts.After the last Awning Tube is attached to the Rafter, remove the 3/8 x 1 bolt from the end connection until the Awning Slip Tubes are installed per the next step.
MAIN AWNING TUBES INSTALLATION64', 70' TRUSS WALL BUILDING
37
AWNING SLIP TUBE INSTALLATION64', 70' TRUSS WALL BUILDING
Install one end of 179758GRY Eave Swaged Slip Tube into the 179947GRY Awning End Tube, LH.The opposite end slides into 172328GRY Eave Double Slip Tube. Slide the bungs of the DoubleSlip Tubes into 179720GRY Awning Center Tubes. These parts are held in place with 1782991/4 x 3/4 Drill Screws. Make sure to install the drill screws from the lower side of Awning tubes tokeep their heads away from the building cover.
Next slide 172329GRY Eave Single Slip Tubes into the remaining Eave Tubes and the remainingAwning Center Tubes and secure with the Drill Screws as before.
The last section is completed by inserting another 179758GRY Eave Swaged Slip Tube betweenthe final Eave Single Slip Tube and 179948GRy Awning End Tube, RH. Reinstall the 3/8 x 1 boltand nut at the last Brace Tube and secure the last Slip Tube with Drill Screws as before.
172329GRY
179758GRY
179947GRY
179948GRY
179720GRY
179758GRY
172328GRY
172329GRY
Reinstall this 3/8 x 1 bolt and nutafter last Slip Tube is installed.
38
AWNING PACKAGES - CURVED ENDS
LENGTH 64'/70' TW BLDGS 30' 40' 50' 60' 70' 80' 90' 100' 110' 120' 130' 140' 150' 160' 170' 180' 190' 200' 210' 220' 230' 240' 250' 260'
PART # 180826-(LENGTH)
PART # DESCRIPTION QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY QTY
179947GRY AWNING END TUBE LH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179948GRY AWNING END TUBE RH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
179720GRY UPPER AWNING CORD 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
180645GRY LOWER TUBE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
172328GRY DOUBLE SLIP TUBE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
172329GRY SINGLE SLIP TUBE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
179758GRY END SWAGED TUBE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
161125 1.29 x 122" TIE DOWN 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
160972 1.29" x 10' SWAGE TUBE 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
154029 3/8"x3.5" BOLT 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55
154019 3/8"x1.0" BOLT 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
154051 3/8" NUT 13 16 19 22 25 28 31 34 37 40 43 46 49 52 55 58 61 64 67 70 73 76 79 82
187299 1/4"x3/4" DRILL SCREW 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53
161754 RATCHET 1'' W/HANDLE 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
184651 STRAP- 1'' X 10FT GREY 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
167642 2 GALLON PAIL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
167644 2/4 GALLON LID 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
173803 DECAL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
170052 1.29" PLUG 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
178838 2" X 28' TIE DOWN STRAP 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
39
MAINTENANCE SCHEDULE
1. One Week Inspection a. The key visual indicator of adequate tension in the building fabric cover and end wall
panel is to ensure all creases and wrinkles in the fabric are removed. Check the ratchet straps for tightness and adjust as necessary. Refer to step 9 of cover installation manual for recommended torque settings for 1" and 2" ratchets.
b. Punctures in the fabric cover caused by accidental damage should be repaired
immediately. The fabric requires a product specific heat seam weld repair. Contact your local Sioux Steel Pro-Tec® building dealer or manufacturer to schedule service.
c. Ensure all tension cables are taut. Cables should not sag. Adjust turnbuckles as
necessary.
2. Installation Adjustment a. The building and end wall panels cover on your SIOUX PRO-TEC® Sentry Building
may relax after installation. It is critical to keep the cover taut (snug) over the rafters and end wall panels taut over end wall framing to prevent wear and ensure a long life. Tighten ratchets and adjust cables as required.
3. Annual Maintenance
a. Repeat 1 Week Inspection (listed above) a minimum of (4) times a year. b. Visually inspect each cross cable for signs of wear and check turnbuckle tension.
Replace and/ or tighten as necessary. c. Check all base plate anchor studs and nuts to assure they are tight. d. Check all ratchet mount and winch bolts and nuts to assure they are tight. e. Check for premature wear of fabric cover, especially where tension is applied and where
there is direct contact with the buildings steel frame. f. Check for premature deterioration of the corrosion protection on the building components.
NOTE: Building covers and end wall panels installed in cooler weather may relax more than covers installed in warm weather. Check tight ness on covers and end wall panels installed in cooler weather on the first available sunny day and adjust cables as necessary. Severe weather conditions may also affe ct your cover, check cover after such conditions occur.
NOTE: Failure to carry out above steps will invalid ate the warranty. WARNING: FLAMMABLE MATERIAL EXPOSURE TO ANY HEAT SOURCE FOR ANY LENGTH OF TIME COULD RESULT IN DAMAGE TO THE FABRIC COVER OR END PANEL MATERIAL. EXHAUST GA SES, SPACE HEATER, WELDING SPARKS, ETC. SHOULD NOT BE ALLOWED TO GET NEAR THE FABRIC PORTION OF STRUCTURE. SIOUX STEEL COMPANY WILL NOT BE RESPONS IBLE FOR ANY DAMAGES OR LIABILITIES RESULTING FROM FAILURE TO HEED THIS WAR NING. THE COVER OR END PANEL MATERIAL STARTS TO DETERIORATE AT EXPOSURE TO 180° TEMPERATURE FOR ANY LENGTH OF TIME. PREVENT PROLONGED CONTACT FROM ANY HEAT SOURCE TO ENSURE MAXIMUM PROTECTION TO THIS MATERIAL. FOR ANY FURTH ER INFORMATION CONTACT SIOUX STEEL COMPANY.
Revised 07/14/2017
NEW PRODUCT WARRANTY PRO-TEC BUILDINGS
LIMITED WARRANTY FOR NEW SIOUX STEEL COMPANY PRODUCTS A. GENERAL PROVISIONS . “Sioux Steel” means Sioux Steel Company, 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104. The warranties described below are provided by Sioux Steel to the original purchasers of new products purchased from Sioux Steel or from an authorized Sioux Steel Dealer (the “Products”). Under these warranties, Sioux Steel will, at its option, repair or replace at its factory any Product covered under these warranties which is found to be defective in material and workmanship during the applicable warranty term or refund the purchase price paid for the defective Product. Customer will be responsible for labor charges for removing the defective Product and reinstalling the repaired or replacement Product, any premium charge for overtime labor requested of Sioux Steel and shipping charges to and from Sioux Steel’s factory. These warranties are not transferrable . B. WARRANTY PERIOD . Subject to exclusions and limitations set forth herein, each new Product is warranted for the number of years specified below. Each warranty term begins from the date of purchase regardless of delay in receipt of the Product by Customer due to the time required to process, handle, ship, assemble, construct and install the Product. Customer must retain proof of the date of purchase. Replacement parts for and repairs to the Product will be warranted only for the remainder of the original warranty term. The replacement parts for or repairs to the Product will not extend the warranty term beyond the original warranty term. Products described below include all parts, components and accessories.
PROTEC BUILDINGS Pro-Tec Poultry Buildings 1 Year Safeguard Livestock Shade 1 Year Pro-Tec Single Tube (24’, 30’, and 36’) Buildings 3 Years All Other Powder-Coated Pro-Tec Buildings in Livestock (other than Poultry) and Chemical Storage Applications 7 Years, Prorated Monthly All Other Powder-Coated Pro-Tec Buildings Except those in Livestock and Chemical Storage Applications 15 Years, Prorated Monthly All Other Hot-Dip Galvanized Pro-Tec Buildings 15 Years, Prorated Monthly Fabricated Tarp Materials (covers) 15 Years, Prorated Monthly Fabricated Tarp Materials for End Panels (All Pro-Tec Buildings) ; Rollup Sides; Curtains and Doors; Track Doors; Quarter Panels and Half Moon End Panels ( On all Building Models)
3 Years, Prorated Monthly
Proration credit will be given toward the purchase price for the replacement of fabric and tarp materials, based on Sioux Steel’s current price list at the time the warranty claim is made.
15 Year Proration Schedule: 7 Year Proration Schedule: Year 1 = 93% Year 4 – 73% Year 7 – 53% Year 10 = 33% Year 13 = 13% Year 1 = 86% Year 4 = 43% Year 7 = 0% Year 2 = 87% Year 5 = 67% Year 8 = 47% Year 11 = 27% Year 14 = 7% Year 2 = 72% Year 5 = 29% Year 3 = 80% Year 6 = 60% Year 9 = 40% year 12 = 20% Year 15 = 0% Year 3 = 58% Year 6 = 15%
Exclusions specific to Pro-Tec Buildings: Damage or loss of any kind from (1) exposure of the fabric cover or end panel material to any heat source for any length of time; (2) a failure to properly compact and engineer soils; (3) a failure to properly construct footings and foundations; and (4) exposure to conditions in excess of the design wind and snow load specifications. NOTICE: Caustic and corrosive environments can resu lt from live animal operations or storage of caustic materials. Sioux Steel reserves the right to exclude from warranty under D(4) if co nditions are deemed by it as extreme. C. ITEMS COVERED SEPARATELY . The Sioux Steel warranties do not cover any parts, components or materials that are part of the Product, or used in conjunction with the Product, that are not manufactured by Sioux Steel. Such parts, components and materials will be subject to the warranties provided by the manufacturer, if any. D. WHAT IS NOT WARRANTED . Sioux Steel does not warrant and is not responsible for the following: (1) used products; (2) modification or alteration of the Products; (3) Products that have not been properly installed or not installed in accordance with the instruction manual, improper assembly, or improper construction by any persons other than Sioux Steel employees; (4) depreciation, damage or loss caused by the use of parts, components or accessories not provided by Sioux Steel, unauthorized repairs, normal wear, lack of necessary and proper maintenance, a failure to follow operating instructions/recommendations, misuse, lack of proper protection during storage, vandalism or theft, exposure to the elements or corrosive materials, accidents or acts of nature including lightning, flooding, hail, straight winds and tornadoes; and (5) cosmetic damage or damage that does not hinder the functionality of the Products. E. LIMITATIONS OF WARRANTIES AND CUSTOMER’S REMEDI ES. To the extent permitted by law, neither Sioux Steel, the Dealer nor any person or company affiliated with either of them makes any warranties, representations, conditions or promises express or implied as to the quality, performance or freedom from defects of the Products covered by these warranties other than those set forth herein. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NEITHER SIOUX STEEL, THE DEALER, NOR ANY PERSON OR COMPANY AFFILIATED WITH EITHER OF THEM WILL BE LIABLE FOR ANY DAMAGES, INCLUDING, BUT NOT LIMITED TO, INCIDENTAL, SPECIAL, EXEMPLARY, CONSEQUENTIAL, LOST PROFITS AND REVENUES, LOST USE OF THE PRODUCTS OR ANY OTHER PROPERTY, BODILY INJURY OR PROPERTY DAMAGE CLAIMS OF ANY PERSON, LOST COMMODITIES, REMOVAL OR STORAGE COSTS FOR THE PRODUCTS, OTHER EQUIPMENT AND COMMODITIES, DAMAGE TO THE ENVIRONMENT ARISING FROM OR IN ANY MANNER RELATED TO ANY RELEASE OF HAZARDOUS MATERIALS, AND REMEDIATION EXPENSES THEREFORE, WHETHER BASED ON CONTRACT, TORT, STRICT LIABILITY OR ANY OTHER LEGAL BASIS, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO INSTANCE WILL SIOUX STEEL, THE DEALER OR ANY PERSON OR COMPANY AFFILIATED WITH EITHER OF THEM BE LIABLE TO CUSTOMER OR ANY PERSON IN AN AMOUNT IN EXCESS OF THE PURCHASE PRICE PAID BY CUSTOMER FOR THE PRODUCT. F. NO DEALER WARRANTY . THE DEALER HAS NO AUTHORITY TO MAKE ANY WARRANTY, REPRESENTATION, CONDITION OR PROMISE ON BEHALF OF SIOUX STEEL, OR TO MODIFY THE TERMS OR LIMITATIONS OF THIS WARRANTY IN ANY WAY. G. GOVERNING LAW/VENUE . These warranties, and all terms set forth herein, are governed by the laws of the State of South Dakota and, where applicable, the laws of the United States of America. Any and all disputes arising from these warranties, the purchase and use of the Products, bodily injury and property damage claims or otherwise must be venued in the South Dakota Circuit Court sitting in Minnehaha County, South Dakota. Customer agrees to such venue and waives any challenge to such court’s jurisdiction based upon lack of personal jurisdiction or inconvenience. H. SECURING WARRANTY SERVICE . In order to receive warranty services, customer must give Sioux Steel written notice of a warranty claim within 3 days of the date of discovery of the defective materials or workmanship, and Customer must complete the following steps:
(1) Obtain from Sioux Steel a Return Goods Authorization Number (“RMA Number”) by calling the Customer Service Department at 1-800-557-4689, and providing the following information:
� An explanation as to why the Product is being returned. � The name of the territory representative, Dealer or Sioux Steel salesperson from whom the Product was
purchased. � The Dealer’s identification number. � The invoice number and date of purchase. � Customer’s name, phone number, fax number, mailing address and email address. � The date that the Product will be returned.
(2) Pay the shipping charges to ship the Product to Sioux Steel’s factory, and the return shipping charges. (3) Ship the Product to Sioux Steel at 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104.
Recommended