23.09.2002 Image Engineering Dietmar Wueller 1
Pro and contra using ISO 12233
for resolution measurement
23.09.2002 Image Engineering Dietmar Wueller 2
SFR Measurement
23.09.2002 Image Engineering Dietmar Wueller 3
SFR Measurement
Figure 4 — Flow-chart of SFR measurement algorithm
23.09.2002 Image Engineering Dietmar Wueller 4
SFR Measurement
SFR Measurement has proven
• Reliability.• High accuracy.
23.09.2002 Image Engineering Dietmar Wueller 5
SFR Measurement
SFR of Leica S1 Pro
0,00
0,20
0,40
0,60
0,80
1,00
0 1000 2000 3000 4000 5000
Frequency [LW/PH]
Sp
atia
l Fre
qu
ency
Res
po
nse
SFRhorizontalSFRvertikal
Mittelwert
Aliasing Region
23.09.2002 Image Engineering Dietmar Wueller 6
SFR Measurement
But problems appear if the camera applies:
• Sharpening.• Aliasing artifacts.• Artifacts caused by JPEG
compression.
23.09.2002 Image Engineering Dietmar Wueller 7
SFR Measurement
SFR Olympus Camedia C-1400XL
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
1,60
0 200 400 600 800 1000
Frequency [LW/PH]
Sp
atia
l Fre
qu
ency
Res
po
nse
SFRhorizontal
SFRvertikal
Mittelwert
Aliasing Region
23.09.2002 Image Engineering Dietmar Wueller 8
SFR Measurement
Consequence:
• The SFR does give the correct edge analysis!
• But the result does not tell anything about the ability of the camera to capture fine detail.
23.09.2002 Image Engineering Dietmar Wueller 9
Visual analysis from ISO 12233 chart
23.09.2002 Image Engineering Dietmar Wueller 10
Visual analysis from ISO 12233 chart
23.09.2002 Image Engineering Dietmar Wueller 11
Visual analysis from ISO 12233 chart
23.09.2002 Image Engineering Dietmar Wueller 12
Kontrast analysis from ISO 12233 chart
0
50
100
150
200
250
100 200 300 400 500 600 700 800 900 1000
Frequency [LW/PH]
Dig
ital
Val
ues
23.09.2002 Image Engineering Dietmar Wueller 13
Contrast analysis from ISO 12233 chart
0,00
10,00
20,00
30,00
40,00
50,00
60,00
70,00
80,00
90,00
100,00
100 200 300 400 500 600 700
Frequency [LW/PH]
Co
ntra
st [
%]
23.09.2002 Image Engineering Dietmar Wueller 14
Problem:
• Where to draw the line for a limiting resolution?!
Contrast analysis from ISO 12233 chart
23.09.2002 Image Engineering Dietmar Wueller 15
Visual analysis from ISO 12233 chart
23.09.2002 Image Engineering Dietmar Wueller 16
Visual analysis from ISO 12233 chart
23.09.2002 Image Engineering Dietmar Wueller 17
Problem:
• Where to draw the line for a limiting resolution?!
Visual analysis from ISO 12233 chart
23.09.2002 Image Engineering Dietmar Wueller 18
Visual analysis from a special chart
23.09.2002 Image Engineering Dietmar Wueller 19
Problem:
• Where to draw the line for a „limiting resolution“?!
• no differentiation between center and edges.
Visual analysis from a special chart
23.09.2002 Image Engineering Dietmar Wueller 20
Visual analysis from a special chart
23.09.2002 Image Engineering Dietmar Wueller 21
Using Siemens stars
23.09.2002 Image Engineering Dietmar Wueller 22
Conclusions
• SRF analysis is the preferred method if we have access to „raw“ data.
• If we do not have raw data a visual analysis consists of a low accuracy.
• A more reliable „calculation“-method is needed for consumer cameras.
• Such a method can be based on Siemens stars.