Water Quality Inserts and Hydrodynamic Devices

Presented By: Jason Bailey, E.I.T.

TopicsTopics

• TestingTesting

• NJ DEP Approval List

i• Maintenance

• Products

• Questions

TestingTesting

• Tests include chemicals and TSS• Few tests include Phosphorus and Nitrates• Manufacturer Testing

– Performed by the Manufacturer– Has a bias is the resultsMost products have– Most products have

• 3rd Party Testing– Independentp– No bias in the results– Verifies Manufacturer TestingLi i d d h– Limited products have

NJ DEP Approval ListNJ DEP Approval ListStormwater Management Manufactured Treatment Devices Certified by NJDEP

Interim Certificationand Expiration Date

FinalCertification

Certified TSSRemoval Rate

AquaFilter Filtration Chamber by AquaShield, Inc. Extension 80%

Aqua‐Swirl Concentrator By Aqua‐Shield. Inc. Extension 50%

Bayfilter by BaySaver Technologies, Inc. Interim 1  80%

BaySeparator by BaySaver Technologies, Inc. Extension 50%

Downstream Defender by Hydro International, Inc. Extension 50%

FloGard Dual‐Vortex Hydrodynamic Separator by KriStar Enterprises, Inc.

Extension 50%

i h ffi i i fl i ( ) iHigh Efficiency Continuous Deflective Separator (CDS) Unitby CONTECH Stormwater Solutions, Inc.

Extension 50%

Hydroguard by Hydroworks, LLC Interim 1 50%

Jellyfish Filter by Imbrium Systems Corporation Extension 80%

Media Filtration Systems  by CONTECH Stormwater Solutions Inc

Extension Final 80%by CONTECH Stormwater Solutions, Inc.

Nutrient Separating Bafflle Box by  Suntree Technologies, Inc. Interim 1 50%

Stormceptor OSRby Imbrium Systems Corporation

Extension 50%

Stormceptor STC by Imbrium Systems Corporation

Extension 50%

StormVault FinalStormVaultby CONTECH Stormwater Solutions, Inc.

Final80%

Stormwater Management StormFilterby CONTECH Stormwater Solutions, Inc.

Final80%

TerreKleen Stormwater Deviceby Terre Hill Concrete Products

Extension 50%

Up‐Flo Filter by Hydro International 80%Up Flo Filter by Hydro International 80%

V2B1 by Environment 21, LLC Interim 1 50%

Vortechs Stormwater Treatment Systemby CONTECH Stormwater Solutions, Inc

Extension 50%

VortSentry System by CONTECH Stormwater Solutions, Inc. Extension 50%

MaintenanceMaintenance

• MaintenanceMaintenance– Frequency and Difficulty

• Inspection• Removal of sediments and debris• Part replacement

Oil/Water Boom– Oil/Water Boom– Filters

• Life Cycle Costy– Product Cost– Maintenance/Cleaning Costg

ProductsProducts• Aqua‐Filter™• Imbrium

Jellyfish– Jellyfish– Sorbtive™ Filter– Stormceptor®

• KriStar– FloGard® Dual‐vortex Hydrodynamic Separator– FloGard® +Plus– The Perk Filter 

Up Flo Filter– Up‐Flo Filter• Snout (BMP Inc.)• SunTree Technologies

– Curb Inlet Basket – Standard™– Grate Inlet Skimmer Box™– Modular Wetlands– Nutrient Separating Baffle Box®– SkimBoss Up‐Flow FilterSkimBoss Up‐Flow Filter

• Terre‐Hill Stormwater Products• Trash Guard• Ultra‐HydroKleen

Aqua‐Filter™Aqua Filter• Manufactured by AquaShield

– Utilizes an Aqua Swirl™ and an Aqua Filter™ unitT ti• Testing:– TSS: 80% reduction, NJ DEP Verified– TP: 80% reduction

TN: No test results– TN: No test results• Maintenance

– Cleaning– Filter media replacementFilter media replacement

ImbriumImbrium• Jellyfish

– Made of a self contained inlet with filtration tubeM f t t ti– Manufacturer testing:

• TSS: 80% reduction, NJ DEP Verified• TP: No test results• TN: No test results

– Maintenance• Cleaning• Filter media replacement

ImbriumImbrium• Sorbtive™ Filter

– Precast box with cartridge filter, to be attached to a storm systemM f t t ti– Manufacturer testing:

• TSS: 80% reduction• TP: 75% reduction• TN: No test results

– Maintenance• Cleaning• Filter media replacement

ImbriumImbrium• Stormceptor®

– Stormwater pollutant removal (STC) system

• Inlet and inline model• Oils rise and sediments fall• Testing:

– TSS: 50% reduction, NJ DEP Verified– TP: No test results– TN: No test resultsTN: No test results

– Oil and sand removal (OSR) system– StormceptorMAX

• Large capacity• Large capacity– Maintenance

• Cleaning at 15% of storageN filt di l t• No filter media replacement

KriStarKriStar• FloGard® Dual‐vortex Hydrodynamic SeparatorHydrodynamic Separator– Inline model– Fits most manholes and vaults– Testing:

• TSS: 50% reduction, NJ DEP VerifiedTP N l• TP: No test results

• TN: No test results

– Maintenance• Cleaning multiple times a year including before and after winter

• No filter media replacementNo filter media replacement

KriStarKriStar• FloGard® +Plus

– Inlet Insert– Inlet Insert– Testing:

• TSS: 80% reductionTSS: 80% reduction• TP: 40% reduction• TN: No test results

– Maintenance• Inspections with cleaning 3 times per year3 times per year

• Replacement of filter 1 time per year

KriStarKriStar• The Perk Filter 

– Inline and Inlet model– Precast structure– Testing:

• TSS: 64% reduction per Sacramento State Office of Water Programs testing

• TP: 37% reduction per Sacramento State Office of Water Programs testingOffice of Water Programs testing

• TN: No test results

– Maintenance• Cleaning multiple times a year including before and after winter

• Filter media to clean and replacement

KriStarKriStar• Up‐Flo Filter

– Inline or inlet systemInline or inlet system– Manhole or Vault based– Precast structure– Testing:

• TSS: 80% reduction, NJ DEP verifiedTP N l• TP: No test results

• TN: No test results

– Maintenance• Cleaning multiple times a year including before and after winter

• Filter media to clean andFilter media to clean and replacement

SunTree TechnologiesSunTree Technologies• Curb Inlet Basket – Standard™

– Inlet insertet se t– Drainage area is each inlet– Removes debris– Testing:

• No testing

– MaintenanceMaintenance• Cleaning screen• Replacement of boom

SunTree TechnologiesSunTree Technologies• Grate Inlet Skimmer Box™

– Inlet insert– Drainage area is each inletRemo es debris– Removes debris

– Testing:• No testing

– Maintenance• Cleaning screen• Replacement of boomReplacement of boom

SunTree TechnologiesSunTree Technologies• Modular Wetlands

– Precast Structure w/ Filter MediaInline or inlet– Inline or inlet

– Testing (Bench):• TSS: 98% reduction• TP: 22% reduction, 69% 

reduction by BioGreen Media• TN: No test results

– Testing (Field):• TSS: 82% reduction%• TP: No test results• TN: 76% reduction

– Maintenance• Cleaning screen and separation• Cleaning screen and separation 

tank• Replacement of filter once it 

changes colors• Media and plants annual care• Media and plants annual care 

with media replacement every 5‐20 yrs.

SunTree TechnologiesSunTree Technologies• Nutrient Separating Baffle Box™Box– Precast Structure– Inline system– Testing (2006 Case Studies):

• TSS: 71% reduction• TP: 38% reduction• TP: 38% reduction• TN: 48% reduction

– Maintenance• Service 1‐4 times per year• Vacuum Tanks• Replacement of oil boom• Replacement of oil boom once it become saturated

SunTree TechnologiesSunTree Technologies• SkimBoss™ UpFlowFilterFilter– Precast Structure

I li t– Inline system

– Testing:N T i• No Testing

– MaintenanceV T k• Vacuum Tanks

• Replacement of media

Snout by BMP, Inc.Snout by BMP, Inc.• Product

– Insert product for multiple li ti d t tapplications and structures

– Not end of the line device– Structure must be 

completely sealedcompletely sealed• Testing (Case Studies):

– TSS: 53% reduction% d i– TP: 41% reduction

– TN: No results• Maintenance

– Cleaning screen and separation tank

– No filter to replace, unless dditi l ti i t ll dadditional options installed

Terre‐Hill Stormwater ProductsTerre Hill Stormwater Products• Products

– Terre Kleen LID Protector

– Terre Hill AgruSureGrip® OWSSureGrip  OWS

• Oil Water Separator– Terre Kleen™

T ti• Testing:– TSS: 50% to 78% reduction

– TP: No results– TN: No results

• Gene LaManna from Terre Hill will presentTerre Hill will present additional information

TrashGuard®TrashGuard• Manufactured by Trash Guard, Inc.– Installs at discharge– Not end of the line device– Maximum 24” PipeMaximum 24  Pipe

• Manufacturer testing:– TSS: No test resultsTP N t t lt– TP: No test results

– TN: No test results• Maintenance

– Vacuum debris from inlet– Removal of trapped solids debris and foreignsolids, debris and foreign matter

Ultra‐HydroKleenUltra HydroKleen• Manufactured by P.E.P.

– Designed to fit each application– Installed directly into an inletInstalled directly into an inlet

• Manufacturer testing:– TSS: 68% reduction– TP: No test results– TN: No test results

• Maintenance– Removal of trapped solids, debris and foreign matter– Media replacement prior to saturation by pollutants– Media replacement prior to saturation by pollutants

QuestionsQuestions

Any Further Questions Please Contact:Jason Bailey E I T Eric KonzelmannJason Bailey, E.I.T. Eric Konzelmann610‐372‐4657 Ext. 128 610‐372‐4657 Ext. 141Jason.Bailey@pa.nacdnet.net Eric.Konzelmann@pa.nacdnet.net

Berks County Conservation District does not endorse or certify any specific manufactured devises. It is up the discretion of the design profession to 

perform adequate research prior to selecting a product.