View
7
Download
0
Category
Preview:
Citation preview
Wiring Diagram: Reader O-1-SPopulus V9 S with
www.jantar.si
Use 12V DC el. strike only!
Check the polarity (+ -)! An improperly connected el. strike can permanently damage Populus!
The power consumption of el. strike must not exceed 250mA!
El. strike
Reader O-1-S
CONNECTION CABLE
Wire Colour Description Populus connector
1 Red 9-14V DC RDR - 12V
2 Gray GND RDR - GND
3 Light blue Rs485 - CA RDR - XA
4 Brown Rs485 - CB RDR - XB
UTP cable up to 200m, see manual
+-
Backup battery, 12V 2.3Ah.Pay attention to the polarity!
El. Strike
Relay
Door status switch
El. strike powerRelay contact, normally open and normally close contact. Maximum current: 5A @ 230V.Initiates together with el. strike output.
NC
NO
* 1. wire is coloured red
1. wire
4. wire
Ethernet connection
110 - 230V AC
Reader O-1-S
Push button
Push button
To local area network
RS 485 line to communication converter
Recommended