Accessories
PLC Migration AdapterYaskawa 2000/1000 I/O seriesSharp JW/ZW series
Safety PrecautionsObserve the voltage and current rating specications shown in this catalog when using our products.
Our products are not intended for use as a part of equipment that will be used under situations in which human life is in
danger. The products shall not be used for any equipment which can directly affect human life. Consult us for your special
applications of our products.
Install appropriate safety devices if using our products for equipment, the failure of which may result in a hazardous situation.
Head ofce/Factory :
270 Fukuoka-cho, Kanshuji, Yamashina-ku, Kyoto, 607-8232 Japan
TEL. 81-75-581-7175 FAX. 81-75-593-9447
Ver 1.12013.06-1KK-1
The specications and other information provided in this catalog may be subject to change without notice.
KYOTO • TOKYO • SHIZUOKA • NAGOYA • HIROSHIMA • KITAKYUSHU
EK-ec
UK-b EK-b
UK-c
Fixtures
Mounting rail Rail end cap
Item
Mounting rail
Rail end cap
Fixtures
Modelname
UK-c
EK-ch
UK-ec
EK-ec
UK-b
EK-b
Applicablerail
—
—
UK-c
EK-ch
UK-c, EK-ch
UK-c, EK-ch
Length
1000, 1500, 2000
1000, 1500, 2000
—
—
—
—
No. of piecesper package
10
10
100
100
100
100
1 2
Conversion cables
PLC Renewal Adaptors: PS-YSJ
Conversion cables support connectors, terminal blocks.
No I/O reassignments required
Migrating outdated PLCs into new PLCs without wiring
ers
FeaturesFeatures
Renew old PLCs from various manufactures including Mitsubishi,JTEKT , Omron and more.
Voltage conversion models allow new PLCs to be rated at 24 VDC.
Toho custom-builds cable that adapt PLCs from all major manufactur with changing connector pin assign.
Small-footprint installation mounts available upon request.
“Low-profile” models with reduced depth available.
PLC Renewal Adaptor Selection TablePLC Renewal Adaptor Selection Table
Yaskawa
2000 I/O
Yaskawa
1000 I/O
Sharp
JW/ZW *1
125 VAC/DC max
125 VAC/DC max
250 VAC/DC max
250 VAC/24 VDC output
250 VAC/24 VDC output
250 VAC/24 VDC output
80-240 VAC output
80-240 VAC output
100/110 VAC input
100/110 VAC input
200/240 VAC input
200/240 VAC input
125 VAC/DC max
125 VAC/DC max
250 VAC/24 VDC output
250 VAC/24 VDC output
48 VDC output
80-240 VAC output
100/110 VAC input
200/240 VAC input
48 VDC output
125 VAC/DC max
125 VAC/DC max
250 VAC/DC max
Model with 20-pole terminal block
Model with 38-pole terminal block
Model with 38-pole terminal block
Model with 20-pole terminal block
Model with 38-pole terminal block
Model with 38-pole terminal block
Model with 24-pole (12P×2) terminal block
Model with 38-pole terminal block
B1090B
B1094
B1056
B1050
B1051B
B1055
B1057
B2500
B2500
B2902
B2504
B2501A
B2505A
B2904 B2914
B2503A
B2507A
Direct coupling
Direct coupling
Direct coupling
Direct coupling
Direct coupling
Relay
Relay
Relay
Relay
Relay
Relay
Triac
Triac
Triac
Triac
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Direct coupling
Direct coupling
Relay
Relay
SSR
Triac
Photocoupler
Photocoupler
Resistor
Direct coupling
Direct coupling
Direct coupling
Direct coupling
Direct coupling
PS-YSJ1
PS-YSJ1-S
PS-YSJ2
PS-YSJ2-S
PS-YSJ2A22
PS-YSJ1-RY1
PS-YSJ1-RY1-S
PS-YSJ2-RY1
PS-YSJ2-RY1-S
PS-YSJ1-RY2
PS-YSJ1-RY2-S
PS-YSJ1-TR1
PS-YSJ1-TR1-S
PS-YSJ2-TR1
PS-YSJ2-TR1-S
PS-YSJ1-PH1
PS-YSJ1-PH2-S
PS-YSJ2-PH1
PS-YSJ2-PH2-S
PS-YSJ1-PH2
PS-YSJ1-PH2-S
PS-YSJ2-PH2
PS-YSJ2-PH2-S
PS-YSJ1000-1
PS-YSJ1000-2
PS-YSJ1000-1-RY1
PS-YSJ1000-0-RY2
PS-YSJ1000-1-RY3
PS-YSJ1000-1-TR1
PS-YSJ1000-1-PH1
PS-YSJ1000-1-PH2
PS-YSJ1000-1-48
PS-YSJ1
PS-YSJ1-S
PS-YSJ2
PS-YSJ2-S
PS-YSJ2A22
Series name Model name/Configuration Voltage rating Voltage rating
New PLCExisting PLC
Model name Circuit
PLC Renewal AdaptorNumber of I/O points
Reference page
Same as existing PLC
Same as existing PLC
Same as existing PLC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Same as existing PLC
Same as existing PLC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Same as existing PLC
Same as existing PLC
Same as existing PLC
16
32
32
16
32
16
16
32
16
32
16
32
16
32
16
8
16
16
16
16
16
16
32
32
*1 Renewal of a ZW series PLC requires an attachment from Sharp Manufacturing System. *2 Please contact us for other existing PLC models than those listed on the above table.
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
5
6
7
The PLC Renewal Adapter allows you to migrate Yaskawa 2000/1000 I/O series PLCs or Sharp JW/ZW series PLCs into new PLC without rewiring and reconnecting cables or rechecking I/O assignments.
Existing PLCs: Yaskawa 2000/1000 I/O series Sharp JW/ZW series
New MP PLCs
Fit PLC migration adapters directly onto existing terminal blocks, without removing wiring.
1 2
Conversion cables
Existing terminal blocks, with the wiring kept in place,can be fitted into the PLC Renewal Adaptors.
PLC Renewal Adaptors: PS-YSJ
Connect conversi
on
cables to new PLCs
Conversion cables support various
connection schemes such as
those using connectors or
terminal blocks.
No I/O reassignments required
Renewal to PLCs from various manufactures including Mitsubishi, JTEKT and Omron allowed
Voltage conversion models permitting new PLCs to be rated at 24 VDC
Conversion cables (connecting to new PLCs) available, which support various connection schemes such as those using connectors or terminal blocks
Installation mounts with a small footprint available on order
“Low-profile” models with a reduced depth also in lineup
Reducing the number of man-hours to one fifth
FeaturesFeatures
PLC Renewal Adaptor Selection
Yaskawa
2000 I/O
Yaskawa
1000 I/O
Sharp
JW/ZW *1
125 VAC/DC max
125 VAC/DC max
250 VAC/DC max
250 VAC/24 VDC output
250 VAC/24 VDC output
250 VAC/24 VDC output
80-240 VAC output
80-240 VAC output
100/110 VAC input
100/110 VAC input
200/240 VAC input
200/240 VAC input
125 VAC/DC max
125 VAC/DC max
250 VAC/24 VDC output
250 VAC/24 VDC output
48 VDC output
80-240 VAC output
100/110 VAC input
200/240 VAC input
48 VDC output
125 VAC/DC max
125 VAC/DC max
250 VAC/DC max
Model with 20-pole terminal block
Model with 38-pole terminal block
Model with 38-pole terminal block
Model with 20-pole terminal block
Model with 38-pole terminal block
Model with 38-pole terminal block
Model with 24-pole (12P×2) terminal block
Model with 38-pole terminal block
B1090B
B1094
B1056
B1050
B1051B
B1055
B1057
B2500
B2500
B2902
B2504
B2501A
B2505A
B2904 B2914
B2503A
B2507A
Direct coupling
Direct coupling
Direct coupling
Direct coupling
Direct coupling
Relay
Relay
Relay
Relay
Relay
Relay
Triac
Triac
Triac
Triac
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Photocoupler
Direct coupling
Direct coupling
Relay
Relay
SSR
Triac
Photocoupler
Photocoupler
Resistor
Direct coupling
Direct coupling
Direct coupling
Direct coupling
Direct coupling
PS-YSJ1
PS-YSJ1-S
PS-YSJ2
PS-YSJ2-S
PS-YSJ2A22
PS-YSJ1-RY1
PS-YSJ1-RY1-S
PS-YSJ2-RY1
PS-YSJ2-RY1-S
PS-YSJ1-RY2
PS-YSJ1-RY2-S
PS-YSJ1-TR1
PS-YSJ1-TR1-S
PS-YSJ2-TR1
PS-YSJ2-TR1-S
PS-YSJ1-PH1
PS-YSJ1-PH2-S
PS-YSJ2-PH1
PS-YSJ2-PH2-S
PS-YSJ1-PH2
PS-YSJ1-PH2-S
PS-YSJ2-PH2
PS-YSJ2-PH2-S
PS-YSJ1000-1
PS-YSJ1000-2
PS-YSJ1000-1-RY1
PS-YSJ1000-0-RY2
PS-YSJ1000-1-RY3
PS-YSJ1000-1-TR1
PS-YSJ1000-1-PH1
PS-YSJ1000-1-PH2
PS-YSJ1000-1-48
PS-YSJ1
PS-YSJ1-S
PS-YSJ2
PS-YSJ2-S
PS-YSJ2A22
Series name Model name/Configuration Voltage rating Voltage rating
New PLCExisting PLC
Model name Circuit
PLC Renewal AdaptorNumber of I/O points
Reference page
Same as existing PLC
Same as existing PLC
Same as existing PLC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Same as existing PLC
Same as existing PLC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Same as existing PLC
Same as existing PLC
Same as existing PLC
16
32
32
16
32
16
16
32
16
32
16
32
16
32
16
8
16
16
16
16
16
16
32
32
*1 Renewal of a ZW series PLC requires an attachment from Sharp Manufacturing System. *2 Please contact Toho Technology for other existing PLC models than those listed on the above table.
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
5
6
7
The PLC Renewal Adaptor allows you to replace a Yaskawa 2000/1000 I/O
series PLC or Sharp JW/ZW series PLC with a new PLC without the need for
reconnecting cables and rechecking I/O assignments.
Existing PLCs: Yaskawa 2000/1000 I/O series Sharp JW/ZW series
New PLCs
3 4
PLC Renewal Adaptor
Conversion Cables
Installation Mounts
Can be custom-made according to your space availability. See pages 4 and 26.
Can be custom-made according to your specification. See page 4.
Coating
Blank: PCB coating not required
CM: PCB coating required
Blank: Single coating
2: Double coating
F: Parts side only
R: Solder side only
W: Both sides
Basic model code
Shape
1: 16 points
2: 32 points
Blank: Direct coupling
A22: Direct coupling (250 VAC allowed)
RY1: Voltage conversion, for output
RY2: Voltage conversion, for output (independent common)
TR1: Voltage conversion, for output (triac output)
PH1: Voltage conversion, for input (100/110 VAC)
PH2: Voltage conversion, for input (200/220 VAC)
Number ofI/O points
0: 8 points
1: 16 points
2: 32 points
Number ofI/O points
PS-YSJ 1 - PH1
Circuit Configuration
Coating
CM F 2S
Blank: PCB coating not required
CM: PCB coating required
Blank: Single coating
2: Double coating
Blank: Standard
S: Low-prole
F: Parts side only
R: Solder side only
W: Both sides
--
*1 If you require a low-prole model with 100 VAC input, you can only select a model with a circuit conguration code of PH2. *2 RY2 is only available in models with a basic model code of PS-YSJ1. *3 Adaptors for Sharp JW series PLCs are all in a direct-coupling circuit conguration. *4 Renewal of a Sharp ZW series PLC requires an attachment from Sharp Manufacturing System.
Blank: Direct coupling
RY1: Voltage conversion, for output
RY2: Voltage conversion, for output (independent common)
RY3: Voltage conversion, for output (independent common)
TR1: Voltage conversion, for output (SSR output)
PH1: Voltage conversion, for input (100/110 VAC)
PH2: Voltage conversion, for input (200/220 VAC)
48: Voltage conversion, for input (Resistor input)
*See pages 17 to 24 for possible combinations of the number of I/O points and the circuit conguration.
Basic model code
PS-YSJ1000 - 1 - PH1
Circuit Configuration
CM F 2-
For Yaskawa 2000 I/O and Sharp JW/ZW series PLCs
For Yaskawa 1000 I/O series PLCs
Ordering Procedure
PLC Renewal AdaptorPLC Renewal Adaptor
Conversion cableConversion cable
Installation mountInstallation mount
11
22
33
The following outlines the ordering procedure.
Choose a new PLC model you want to use in place of the existing PLC model.
Advise us the model names of the existing PLC and the new PLC you have chosen.(You may be requested to provide us with additional information on the PLCs concerned.)
Finally choose what PLC Renewal Adaptor model to use.
The specification is finally determined.
The specification is finally determined.
We suggest a recommended PLC Renewal Adaptor model(s).
Advise us the I/O signal names of the existing and new PLCs.
We prepare a delivery specification and submit it for your approval.
The specification is checked.
Provide us with information including outer dimensions of the existing mount andthe space available for the new mount.
We prepare a delivery specification and submit it for your approval.
The specification is checked.
Some working or loading conditions could hinder the proper function of the Adaptor. Pay due attention to these conditions in advance.
(see page 26)
Ordering Information
3 4
PLC Renewal Adaptor
Conversion cables
Installation mounts
Can be custom-made according to your space availability. See pages 4 and 26.
Can be custom-made according to your specification. See page 4.
Coating
Blank: PCB coating not required
CM: PCB coating required
Blank: Single coating
2: Double coating
F: Parts side only
R: Solder side only
W: Both sides
Basic model code
Shape
1: 16 points
2: 32 points
Blank: Direct coupling
A22: Direct coupling (250 VAC allowed)
RY1: Voltage conversion, for output
RY2: Voltage conversion, for output (independent common)
TR1: Voltage conversion, for output (triac output)
PH1: Voltage conversion, for input (100/110 VAC)
PH2: Voltage conversion, for input (200/220 VAC)
Number ofI/O points
0: 8 points
1: 16 points
2: 32 points
Number ofI/O points
PS-YSJ 1 - PH1
Circuit configuration
Coating
CM F 2S
Blank: PCB coating not required
CM: PCB coating required
Blank: Single coating
2: Double coating
Blank: Standard
S: Low-prole
F: Parts side only
R: Solder side only
W: Both sides
--
*1 If you require a low-prole model with 100 VAC input, you can only select a model with a circuit conguration code of PH2. *2 RY2 is only available in models with a basic model code of PS-YSJ1. *3 Adaptors for Sharp JW series PLCs are all in a direct-coupling circuit conguration. *4 Renewal of a Sharp ZW series PLC requires an attachment from Sharp Manufacturing System.
Blank: Direct coupling
RY1: Voltage conversion, for output
RY2: Voltage conversion, for output (independent common)
RY3: Voltage conversion, for output (independent common)
TR1: Voltage conversion, for output (SSR output)
PH1: Voltage conversion, for input (100/110 VAC)
PH2: Voltage conversion, for input (200/220 VAC)
48: Voltage conversion, for input (Resistor input)
*See pages 17 to 24 for possible combinations of the number of I/O points and the circuit conguration.
Basic model code
PS-YSJ1000 - 1 - PH1
Circuit configuration
CM F 2-
For Yaskawa 2000 I/O and Sharp JW/ZW series PLCs
For Yaskawa 1000 I/O series PLCs
Ordering Procedure
PLC Renewal AdaptorPLC Renewal Adaptor
Conversion Cable
Installation Mount
11
22
33
The following outlines the ordering procedure.
Choose a new PLC model you want to use in place of the existing PLC model.
Advise us of the model names of the existing PLC and the new PLC you have chosen.
(You may be requested to provide us with additional information on the PLCs concerned.)
Finally choose what PLC Renewal Adaptor model to use.
The specification is confirmed.
The specification is confirmed.
We will provide a recommendation for a PLC Renewal Adapter model.
Advise us of the I/O signal names of the existing and new PLCs.
We prepare a delivery specification and submit it for your approval.
The specification is checked.
Provide us with information including outer dimensions of the existing mount andthe space available for the new mount.
We prepare a delivery specification and submit it for your approval.
The specification is checked.
Some working or loading conditions could hinder the proper function of the Adaptor. Pay due attention to these conditions in advance.
(see page 26)
Ordering Information – Model DesignationsOrdering Information – Model Designations
* The product comes with no terminal block.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
Terminal block of existing PLC
24.7
1ø5
.536
.6
206.5223
To new PLC
90
CN
2C
N1
B3
A1
0A
9A
8A
7A
6A
5A
4A
3A
2A
1B
2B
1
CN
1B
10
B9
B8
B7
B6
B5
B4
B3
A1
0A
9A
8A
7A
6A
5A
4A
3A
2A
1B
2B
1
CN
2B
10
B9
B8
B7
B6
B5
B4
7654321TB 18
17
16
15
14
13
12
11
1098 19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
24.7
60ø5
46
CN
1
CN
2
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block. DIN rail
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
5 6
Direct-coupling models
PS-YSJ1(24 – 100 V supported)
For 16-point input/output module Circuit configuration: Direct coupling
Direct-coupling modelsFor 32-point input/output module
Circuit configuration: Direct coupling
* The product comes with no terminal block.
* The product comes with no terminal block.
PLC with 20-pole terminal block (B2601)
StandardStandard
PS-YSJ1-S(24 – 100 V supported)
Low-profileLow-profile
PS-YSJ2(24 – 100 V supported)
StandardStandard
PS-YSJ2-S(24 – 100 V supported)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
15
Terminal block of existing PLC
Terminal block of existing PLC
190
ø5.5
36.6
206.5223
To new PLCC
N1
2019
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1
B10 B9
B8
B7
B6
B5
B4
7654321TB 18171615141312111098
* PS-YSJ-S is not applicable for triac output.
1560
ø546
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
CN
1
CN
2
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
DIN rail
To new PLC
Signal output (new-PLC side)Rated voltageRated current
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting, DIN rail mounting (for low-prole model only)
1000 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PLC with 38-pole terminal block (B2603, B2604)Signal output (new-PLC side)Rated voltageRated current
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting, DIN rail mounting (for low-prole model only)
1000 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
* The product comes with no terminal block.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
Terminal block of existing PLC
24.7
1ø5
.536
.6
206.5223
To new PLC
90
CN
2C
N1
B3
A1
0A
9A
8A
7A
6A
5A
4A
3A
2A
1B
2B
1
CN
1B
10
B9
B8
B7
B6
B5
B4
B3
A1
0A
9A
8A
7A
6A
5A
4A
3A
2A
1B
2B
1
CN
2B
10
B9
B8
B7
B6
B5
B4
7654321TB 18
17
16
15
14
13
12
11
1098 19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
24.7
60ø5
46
CN
1
CN
2
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block. DIN rail
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
5 6
Direct-coupling models
PS-YSJ1(24 – 100 V supported)
For 16-point input/output module Circuit configuration: Direct coupling
Direct-coupling modelsFor 32-point input/output module
Circuit configuration: Direct coupling
* The product comes with no terminal block.
* The product comes with no terminal block.
PLC with 20-pole terminal block (B2601)
StandardStandard
PS-YSJ1-S(24 – 100 V supported)
Low-profileLow-profile
PS-YSJ2(24 – 100 V supported)
StandardStandard
PS-YSJ2-S(24 – 100 V supported)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
15
Terminal block of existing PLC
Terminal block of existing PLC
190
ø5.5
36.6
206.5223
To new PLC
CN
1
2019
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1
B10 B9
B8
B7
B6
B5
B4
7654321TB 18171615141312111098
* PS-YSJ-S is not applicable for triac output.
1560
ø546
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
CN
1
CN
2
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
DIN rail
To new PLC
Signal output (new-PLC side)Rated voltageRated current
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting, DIN rail mounting (for low-prole model only)
1000 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PLC with 38-pole terminal block (B2603, B2604)Signal output (new-PLC side)Rated voltageRated current
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting, DIN rail mounting (for low-prole model only)
1000 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
7 8
* The product comes with no terminal block.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
Terminal block of existing PLC
24.7
1ø5
.536
.6
206.5
223
To new PLC
90
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X1
X2
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1TB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
5211
ø4.5201 5
151
9036
.6
CN
1
1560
ø546
CN
1
CN
2
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
38373635343332313029282726252423222120198 9 10 11 12 13 14 15 16 17 18TB 1 2 3 4 5 6 7A
4B
3A
3B
2A
2B
1A
1C
N1
B10
A10B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
CN
2A
1B
1A
2B
2A
3B
3A
4B
4A
5B
5A
6B
6A
7B
7A
8B
8A
9B
9A
10B
10
* Supply power to new PLC through conversion cable. 24V
Direct-coupling modelsFor 32-point input/output module
Circuit configuration: Direct coupling
Voltage conversion modelFor 16-point output moduleCircuit configuration: Relay
PS-YSJ2A22(24 – 250 V supported)
StandardStandard
PS-YSJ1-RY1(Contact output)
StandardStandard
PLC with 38-pole terminal block (B2902, B2507A)Signal output (new-PLC side)Rated voltageRated currentMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector250 VAC/DC1ADirect mounting
1000 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PS-YSJ1-RY1-S(Contact output)
Low-profileLow-profile
* The product comes with no terminal block.
* The product comes with no terminal block.
Terminal block of existing PLC
Terminal block of existing PLC
To new PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
B2500Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)RelayDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
* These models do not deliver triac output.
7 8
* The product comes with no terminal block.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
Terminal block of existing PLC
24.7
1ø5
.536
.6
206.5
223
To new PLC
90
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X1
X2
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1TB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
5211
ø4.5201 5
151
9036
.6
CN
1
1560
ø546
CN
1
CN
2
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
38373635343332313029282726252423222120198 9 10 11 12 13 14 15 16 17 18TB 1 2 3 4 5 6 7A
4B
3A
3B
2A
2B
1A
1C
N1
B10
A10B9
A9
B8
A8
B7
A7
B6
A6
B5
A5
B4
CN
2A
1B
1A
2B
2A
3B
3A
4B
4A
5B
5A
6B
6A
7B
7A
8B
8A
9B
9A
10B
10
* Supply power to new PLC through conversion cable. 24V
Direct-coupling modelsFor 32-point input/output module
Circuit configuration: Direct coupling
Voltage conversion modelFor 16-point output moduleCircuit configuration: Relay
PS-YSJ2A22(24 – 250 V supported)
StandardStandard
PS-YSJ1-RY1(Contact output)
StandardStandard
PLC with 38-pole terminal block (B2902, B2507A)Signal output (new-PLC side)Rated voltageRated currentMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector250 VAC/DC1ADirect mounting
1000 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PS-YSJ1-RY1-S(Contact output)
Low-profileLow-profile
* The product comes with no terminal block.
* The product comes with no terminal block.
Terminal block of existing PLC
Terminal block of existing PLC
To new PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
B2500Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)RelayDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
* These models do not deliver triac output.
9 10
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
P
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PN
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
11
23
45
67
89
1011
1213
1415
1617
1819
2021
2223
2425
2627
2829
3031
3233
3435
3637
38
TB1
X25
X26
X27
X28
X29
X30
X31
X32
X17
X18
X19
X20
X21
X22
X23
X24X9
X10
X11
X12
X13
X14
X15
X16
CN
2
TB1
3837
3635
3433
3231
3029
2827
2625
2423
2221
2019
1817
1615
1413
1211
109
87
65
43
21
CN
1
A1
B1
A1
B1
A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10 A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10
NP
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X18
X17 N
P
X2
X1
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X17
X18
X1
X2
X3
X4
X5
X6
X7
X8
24.7
1ø5
.536
.6
206.5223
90
CN
2C
N1
24.7
60
ø546
CN
1
CN
2
24.7
60
ø546
24.7
1ø5
.536
.6
206.5223
90
CN
1
CN
2
24 VDC 24 VDC
CN
1
Voltage conversion modelFor 32-point output moduleCircuit configuration: Relay
Voltage conversion modelFor 16-point output moduleCircuit configuration: Relay
PS-YSJ2-RY1(Contact output)
StandardStandard
PS-YSJ2-RY1-S(Contact output)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2902Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)RelayDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
B2904, B2914Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Independent common
Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2ARelayDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PS-YSJ1-RY2(Contact output/Independent common)
StandardStandard
PS-YSJ1-RY2-S(Contact output/Independent common)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* Relays used are not Bestact™ relays from Yaskawa.
9 10
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
P
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PN
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
11
23
45
67
89
1011
1213
1415
1617
1819
2021
2223
2425
2627
2829
3031
3233
3435
3637
38
TB1
X25
X26
X27
X28
X29
X30
X31
X32
X17
X18
X19
X20
X21
X22
X23
X24X9
X10
X11
X12
X13
X14
X15
X16
CN
2
TB1
3837
3635
3433
3231
3029
2827
2625
2423
2221
2019
1817
1615
1413
1211
109
87
65
43
21
CN
1
A1
B1
A1
B1
A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10 A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10
NP
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X18
X17 N
P
X2
X1
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X17
X18
X1
X2
X3
X4
X5
X6
X7
X8
24.7
1ø5
.536
.6
206.5223
90
CN
2C
N1
24.7
60
ø546
CN
1
CN
2
24.7
60
ø546
24.7
1ø5
.536
.6
206.5223
90
CN
1
CN
2
24 VDC 24 VDC
CN
1
Voltage conversion modelFor 32-point output moduleCircuit configuration: Relay
Voltage conversion modelFor 16-point output moduleCircuit configuration: Relay
PS-YSJ2-RY1(Contact output)
StandardStandard
PS-YSJ2-RY1-S(Contact output)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2902Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)RelayDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
B2904, B2914Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Independent common
Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2ARelayDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PS-YSJ1-RY2(Contact output/Independent common)
StandardStandard
PS-YSJ1-RY2-S(Contact output/Independent common)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* Relays used are not Bestact™ relays from Yaskawa.
11 12
1ø4
.5
36.6
5 221 5231
24.7
90
CN
2C
N1
X25
X26
X27
X28
X29
X30
X31
X32
X17
X18
X19
X20
X21
X22
X23
X24X9
X10
X11
X12
X13
X14
X15
X16
TB1
3837
3635
3433
3231
3029
2827
2625
2423
2221
2019
1817
1615
1413
1211
109
87
65
43
21
NP
NP
X2
X1
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X17
X18
X1
X2
X3
X4
X5
X6
X7
X8
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X1
X2
X1
X2
X3
X4
X5
X6
X7
X8
X9 X10
X11
X12
X13
X14
X15
X16
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
11TB 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
24.7
60ø5
46
CN
1
CN
2
1560
ø546
CN
1
CN
2
5211
ø4.5
201 5
151
9036
.6
CN
1
24 VDC
24 VDC
Voltage conversion modelFor 16-point output moduleCircuit configuration: Triac
Voltage conversion modelFor 32-point output moduleCircuit configuration: Triac
PS-YSJ1-TR1(Triac output)
StandardStandard
PS-YSJ2-TR1(Triac output)
StandardStandard
PS-YSJ1-TR1-S(Triac output)
Low-profileLow-profile
PS-YSJ2-TR1-S(Triac output)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* Supply power to new PLC through conversion cable.
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2500Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance(500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector80 – 240 VAC (existing-PLC side), 24 VDC (new-PLC side)0.6A (2.4A per common)TriacDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
CN
2
CN
1
A1
B1
A1
B1
A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10 A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X18
X17
B2504Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
16
Connector80 – 240 VAC (existing-PLC side), 24 VDC (new-PLC side)0.6A (2.4A per common)TriacDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
11 12
1ø4
.5
36.6
5 221 5231
24.7
90
CN
2C
N1
X25
X26
X27
X28
X29
X30
X31
X32
X17
X18
X19
X20
X21
X22
X23
X24X9
X10
X11
X12
X13
X14
X15
X16
TB1
3837
3635
3433
3231
3029
2827
2625
2423
2221
2019
1817
1615
1413
1211
109
87
65
43
21
NP
NP
X2
X1
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X17
X18
X1
X2
X3
X4
X5
X6
X7
X8
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X16
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X1
X2
X1
X2
X3
X4
X5
X6
X7
X8
X9 X10
X11
X12
X13
X14
X15
X16
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
11TB 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
24.7
60ø5
46
CN
1
CN
2
1560
ø546
CN
1
CN
2
5211
ø4.5
201 5
151
9036
.6
CN
1
24 VDC
24 VDC
Voltage conversion modelFor 16-point output moduleCircuit configuration: Triac
Voltage conversion modelFor 32-point output moduleCircuit configuration: Triac
PS-YSJ1-TR1(Triac output)
StandardStandard
PS-YSJ2-TR1(Triac output)
StandardStandard
PS-YSJ1-TR1-S(Triac output)
Low-profileLow-profile
PS-YSJ2-TR1-S(Triac output)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* Supply power to new PLC through conversion cable.
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2500Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance(500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector80 – 240 VAC (existing-PLC side), 24 VDC (new-PLC side)0.6A (2.4A per common)TriacDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
YO
SH
IDA
ELE
CTR
IC IN
DU
STR
Y C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
CN
2
CN
1
A1
B1
A1
B1
A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10 A3
A4
A5
A6
A7
A8
A9
A10B3
B4
B5
B6
B7
B8
B9
B10
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
X32
X31
X30
X29
X28
X27
X26
X25
X24
X23
X22
X21
X20
X19
X18
X17
B2504Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
16
Connector80 – 240 VAC (existing-PLC side), 24 VDC (new-PLC side)0.6A (2.4A per common)TriacDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
13 14
9 10 11 12 13 14 15 1687654321
16151413121110987654321
N
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1TB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
CN
2
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
N
P17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 321 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
P
1 2 3 4 5 6 7 8 161514131211109 2423222120191817 3231302928272625
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
TB
1
24.7
60
ø546
CN
1
CN
2
1560
ø546
CN
1
CN
2
1ø4
.536
.6
5 221 5231
24.7
90
CN
2C
N1
5211
ø4.5
201 5
151
9036
.6
CN
1
24 VDC24 VDC
* These models can be used with either of 100/110 VAC and 200/240 VAC.
Voltage conversion modelFor 16-point 100/110 VAC input module
Circuit configuration: Photocoupler
Voltage conversion modelFor 32-point 100/110 VAC input module
Circuit configuration: Photocoupler
PS-YSJ1-PH1(Conversion of 100/110 VAC to 24 VDC)
StandardStandard
PS-YSJ1-PH2-S(Conversion of 100/110 VAC to 24 VDC)
Low-profileLow-profile
PS-YSJ2-PH1(Conversion of 100/110 VAC to 24 VDC)
StandardStandard
PS-YSJ2-PH2-S(Conversion of 100/110 VAC to 24 VDC)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2501ANumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)
Photocoupler ON voltageCircuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector100/110 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA (for standard model), 5 mA (for low-prole model)50 VACPhotocouplerDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
B2505ANumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)Photocoupler ON voltageCircuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
16
Connector100/110 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA50 VACSSR or photocouplerDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
* These models can be used with either of 100/110 VAC and 200/240 VAC. * The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
CN
1
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
13 14
9 10 11 12 13 14 15 1687654321
16151413121110987654321
N
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1TB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
CN
2
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
N
P17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 321 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
P
1 2 3 4 5 6 7 8 161514131211109 2423222120191817 3231302928272625
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
TB
1
24.7
60
ø546
CN
1
CN
2
1560
ø546
CN
1
CN
2
1ø4
.536
.6
5 221 5231
24.7
90
CN
2C
N1
5211
ø4.5
201 5
151
9036
.6
CN
1
24 VDC24 VDC
* These models can be used with either of 100/110 VAC and 200/240 VAC.
Voltage conversion modelFor 16-point 100/110 VAC input module
Circuit configuration: Photocoupler
Voltage conversion modelFor 32-point 100/110 VAC input module
Circuit configuration: Photocoupler
PS-YSJ1-PH1(Conversion of 100/110 VAC to 24 VDC)
StandardStandard
PS-YSJ1-PH2-S(Conversion of 100/110 VAC to 24 VDC)
Low-profileLow-profile
PS-YSJ2-PH1(Conversion of 100/110 VAC to 24 VDC)
StandardStandard
PS-YSJ2-PH2-S(Conversion of 100/110 VAC to 24 VDC)
Low-profileLow-profile
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2501ANumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)
Photocoupler ON voltageCircuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector100/110 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA (for standard model), 5 mA (for low-prole model)50 VACPhotocouplerDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
B2505ANumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)Photocoupler ON voltageCircuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
16
Connector100/110 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA50 VACSSR or photocouplerDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
* These models can be used with either of 100/110 VAC and 200/240 VAC. * The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
CN
1
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
15 16
CN
2
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1
N
P17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 321 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
P
1 2 3 4 5 6 7 8 161514131211109 2423222120191817 3231302928272625
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
TB
1
9 10 11 12 13 14 15 1687654321
16151413121110987654321
N
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1TB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1ø4
.536
.6
5 221 5231
24.7
90
CN
2C
N1
5
211
ø4.5
201 5
151
9036
.6
CN
1
24.7
60
ø546
CN
1
CN
2
1560
ø546
CN
1
CN
2
24 VDC24 VDC
* These models can be used with either of 100/110 VAC and 200/240 VAC.
Voltage conversion modelFor 16-point 200/240 VAC input module
Circuit configuration: Photocoupler
Voltage conversion modelFor 32-point 200/240 VAC input module
Circuit configuration: Photocoupler
PS-YSJ1-PH2(Conversion of 200/240 VAC to 24 VDC)
StandardStandard
PS-YSJ1-PH2-S(Conversion of 200/240 VAC to 24 VDC)
Low-profileLow-profile
PS-YSJ2-PH2(Conversion of 200/240 VAC to 24 VDC)
StandardStandard
PS-YSJ2-PH2-S(Conversion of 200/240 VAC to 24 VDC)
Low-profileLow-profile
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2503ANumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)
Photocoupler ON voltage
Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector200/240 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA (for standard model), 5 mA (for low-prole model)100 VAC (for standard model), 50 VAC (for low-prole model)SSR or photocoupler insulationDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
B2507A
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
* These models can be used with either of 100/110 VAC and 200/240 VAC. * The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)
Photocoupler ON voltage
Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
16
Connector200/240 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA (for standard model), 5 mA (for low-prole model)100 VAC (for standard model), 50 VAC (for low-prole model)SSR or photocoupler insulationDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
15 16
CN
2
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1
N
P17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 321 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
P
1 2 3 4 5 6 7 8 161514131211109 2423222120191817 3231302928272625
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
TB
1
9 10 11 12 13 14 15 1687654321
16151413121110987654321
N
P
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
CN
1TB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1ø4
.536
.6
5 221 5231
24.7
90
CN
2C
N1
5
211
ø4.5
201 5
151
9036
.6
CN
1
24.7
60
ø546
CN
1
CN
2
1560
ø546
CN
1
CN
2
24 VDC24 VDC
* These models can be used with either of 100/110 VAC and 200/240 VAC.
Voltage conversion modelFor 16-point 200/240 VAC input module
Circuit configuration: Photocoupler
Voltage conversion modelFor 32-point 200/240 VAC input module
Circuit configuration: Photocoupler
PS-YSJ1-PH2(Conversion of 200/240 VAC to 24 VDC)
StandardStandard
PS-YSJ1-PH2-S(Conversion of 200/240 VAC to 24 VDC)
Low-profileLow-profile
PS-YSJ2-PH2(Conversion of 200/240 VAC to 24 VDC)
StandardStandard
PS-YSJ2-PH2-S(Conversion of 200/240 VAC to 24 VDC)
Low-profileLow-profile
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
B2503ANumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)
Photocoupler ON voltage
Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector200/240 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA (for standard model), 5 mA (for low-prole model)100 VAC (for standard model), 50 VAC (for low-prole model)SSR or photocoupler insulationDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
B2507A
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSH
IDA
ELEC
TRIC
IND
UST
RY C
O.,L
TD.
* These models can be used with either of 100/110 VAC and 200/240 VAC. * The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
Overall length when direct-mounted: 240 Overall length when mounted on DIN rail: 223.5
Mounting pitch when direct-mounted: 219
DIN rail
* The product comes with no terminal block.
Terminal block of existing PLCTo new PLC
B10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
B1
A1
Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)
Photocoupler ON voltage
Circuit conguration
Mounting scheme
Insulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
16
Connector200/240 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA (for standard model), 5 mA (for low-prole model)100 VAC (for standard model), 50 VAC (for low-prole model)SSR or photocoupler insulationDirect mounting, DIN rail mounting (for low-prole model only)
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
17 18
9532
CN
2C
N1
TB-A TB-B
33.6
ø5.5
223
210
1
95
CN
2C
N1
1
210
24.5
ø5.5
33.6
223
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
2B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11 3837363534333231181716151413
B3
B2
A10 A9
A8
A7
A6
A5
A4
A3
A2
B1
A1
CN
1
B10 B9
B8
B7
B6
B5
B4
B3
B2
A10 A9
A8
A7
A6
A5
A4
A3
A2
B1
A1
CN
2
B10 B9
B8
B7
B6
B5
B4
7654321TB 12111098 19 20 21 22 23 24 25 26 27 28 29 30
Direct-coupling modelsFor 16-point input/output module
Circuit configuration: Direct coupling
Voltage conversion modelFor 32-point input/output module
Circuit configuration: Direct coupling
PS-YSJ1000-1(24 – 100 V supported)
StandardStandard
PS-YSJ1000-2(24 – 100 V supported)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
PLC with 24-pole (12-pole x 2) terminal block (B1059C)
Signal output (new-PLC side)Rated voltageRated currentMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PLC with 38-pole terminal block (B1062, B1063)Signal output (new-PLC side)Rated voltageRated currentMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
17 18
9532
CN
2C
N1
TB-A TB-B
33.6
ø5.5
223
210
1
95
CN
2C
N1
1
210
24.5
ø5.5
33.6
223
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
2B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11 3837363534333231181716151413
B3
B2
A10 A9
A8
A7
A6
A5
A4
A3
A2
B1
A1
CN
1
B10 B9
B8
B7
B6
B5
B4
B3
B2
A10 A9
A8
A7
A6
A5
A4
A3
A2
B1
A1
CN
2
B10 B9
B8
B7
B6
B5
B4
7654321TB 12111098 19 20 21 22 23 24 25 26 27 28 29 30
Direct-coupling modelsFor 16-point input/output module
Circuit configuration: Direct coupling
Voltage conversion modelFor 32-point input/output module
Circuit configuration: Direct coupling
PS-YSJ1000-1(24 – 100 V supported)
StandardStandard
PS-YSJ1000-2(24 – 100 V supported)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
PLC with 24-pole (12-pole x 2) terminal block (B1059C)
Signal output (new-PLC side)Rated voltageRated currentMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
PLC with 38-pole terminal block (B1062, B1063)Signal output (new-PLC side)Rated voltageRated currentMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector125 VAC/DC1ADirect mounting
100 Mohm min. (to GND)
2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
Circuit diagramCircuit diagram
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
19 20
PS-YSJ1000-1-RY1
1
9033
.6
TB-BTB-A
ø5.5
ø5.5
223
24.5
210
CN
1
N
PX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
PS-YSJ1000-0-RY2X
8
X7
X6
X5
X4
X3
X2
B11
B10B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
A7
A8
A9
A10
A11
TB-A
A0
A1
A2
A3
A4
A5
A6
B4
B5
B6
B7
B8
B9
B10
CN
1
B1
B2
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10B3
TB-B
X1
X8
X7
X6
X5
X4
X3
X2
X1 P
N
24 VDC24 DCV
PX1 X2 X3 X4 X5 X6 X7 X8 X9 X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10
X9X8X7X6X5X4X3X2X1
X16
X15
X14
X13
X12
X11
X10
X9X8X7X6X5X4X3X2X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
45.6
105
1
210
TB-BTB-A
CN
1
32
223
PS-YSJ1000-1-RY1: B1090B
PS-YSJ1000-0-RY2: B1094
* Supply power to new PLC through conversion cable. 24 VDC
Voltage conversion modelFor 16-point/8-point output module
Circuit configuration: Relay
Voltage conversion modelFor 16-point output moduleCircuit configuration: SSR
PS-YSJ1000-1-RY1(16 points, Contact output)
PS-YSJ1000-0-RY2(8 points, Contact output/Independent common)
StandardStandard
PS-YSJ1000-1-RY3(SSR output)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
Number of points per common (existing-PLC side)
Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8 (PS-YSJ-1-RY1)Independent common (PS-YSJ1000-0-RY2)Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)RelayDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
B1056Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector48 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)SSRDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
19 20
PS-YSJ1000-1-RY1
1
9033
.6
TB-BTB-A
ø5.5
ø5.5
223
24.5
210
CN
1
N
PX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
PS-YSJ1000-0-RY2
X8
X7
X6
X5
X4
X3
X2
B11
B10B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
A7
A8
A9
A10
A11
TB-A
A0
A1
A2
A3
A4
A5
A6
B4
B5
B6
B7
B8
B9
B10
CN
1
B1
B2
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10B3
TB-B
X1
X8
X7
X6
X5
X4
X3
X2
X1 P
N
24 VDC24 DCV
PX1 X2 X3 X4 X5 X6 X7 X8 X9 X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10
X9X8X7X6X5X4X3X2X1
X16
X15
X14
X13
X12
X11
X10
X9X8X7X6X5X4X3X2X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
45.6
105
1
210
TB-BTB-A
CN
1
32
223
PS-YSJ1000-1-RY1: B1090B
PS-YSJ1000-0-RY2: B1094
* Supply power to new PLC through conversion cable. 24 VDC
Voltage conversion modelFor 16-point/8-point output module
Circuit configuration: Relay
Voltage conversion modelFor 16-point output moduleCircuit configuration: SSR
PS-YSJ1000-1-RY1(16 points, Contact output)
PS-YSJ1000-0-RY2(8 points, Contact output/Independent common)
StandardStandard
PS-YSJ1000-1-RY3(SSR output)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram Circuit diagramCircuit diagram
Number of points per common (existing-PLC side)
Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8 (PS-YSJ-1-RY1)Independent common (PS-YSJ1000-0-RY2)Connector250 VAC/24 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)RelayDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
B1056Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector48 VDC (existing-PLC side), 24 VDC (new-PLC side)2A (5A per common)SSRDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
21 22
1
9033
.6
TB-BTB-A
ø5.5
223
24.5
210
CN
1
1
9033
.6
TB-BTB-A
ø5.5
223
24.5
210
CN
1
N
PX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
24 VDC
P
NX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1
B10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
24 VDC
Voltage conversion modelFor 16-point output moduleCircuit configuration: Triac
Voltage conversion modelFor 16-point 100/110 VAC input module
Circuit configuration: Photocoupler
PS-YSJ1000-1-TR1(Triac output)
StandardStandard
PS-YSJ1000-1-PH1(Conversion of 100/110 VAC to 24 VDC)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram
B1050Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector80 – 240 VAC (existing-PLC side), 24 VDC (new-PLC side)0.6A (2.4A per common)TriacDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram
B1051BNumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)Photocoupler ON voltageCircuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector100/110 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA50 VACPhotocouplerDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
21 22
1
9033
.6
TB-BTB-A
ø5.5
223
24.5
210
CN
1
1
9033
.6
TB-BTB-A
ø5.5
223
24.5
210
CN
1
N
PX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1B
10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
24 VDC
P
NX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1
B10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
24 VDC
Voltage conversion modelFor 16-point output moduleCircuit configuration: Triac
Voltage conversion modelFor 16-point 100/110 VAC input module
Circuit configuration: Photocoupler
PS-YSJ1000-1-TR1(Triac output)
StandardStandard
PS-YSJ1000-1-PH1(Conversion of 100/110 VAC to 24 VDC)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram
B1050Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (output side)Circuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector80 – 240 VAC (existing-PLC side), 24 VDC (new-PLC side)0.6A (2.4A per common)TriacDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram
B1051BNumber of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)Photocoupler ON voltageCircuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector100/110 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA50 VACPhotocouplerDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
23 24
1
9033
.6
TB-BTB-A
ø5.5
223
24.5
210
CN
1
P
NX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1
B10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
24 VDC
B11
B10B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
A7
A8
A9
A10
A11
TB-A
A0
A1
A2
A3
A4
A5
A6
B4
B5
B6
B7
B8
B9
B10
CN
1
B2
A2
B1
A1
A3
A4
A5
A6
A7
A8
A9
A10B3
TB-B
5.6
kΩ/1
W
1
210
223
ø5.5
33.6
TB-BTB-A
CN
1C
N2
3295
Voltage conversion modelFor 16-point 200/240 VAC input module
Circuit configuration: Photocoupler
Voltage conversion modelFor 16-point input module
Circuit configuration: Resistor
PS-YSJ1000-1-PH2(Conversion of 200/240 VAC to 24 VDC)
StandardStandard
PS-YSJ1000-1-48(Resistor input)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram
B1055Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)Photocoupler ON voltageCircuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector200/240 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA100 VACPhotocouplerDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
Circuit diagramCircuit diagram
B1057Signal output (new-PLC side)
Rated voltage
Input impedanceCircuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector48 VDC (existing-PLC side), 24 VDC (new-PLC side)5.6 kΩResistorDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
23 24
1
9033
.6
TB-BTB-A
ø5.5
223
24.5
210
CN
1
P
NX1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X16
X15
X14
X13
X12
X11
X10X9
X8
X7
X6
X5
X4
X3
X2
X1
TB-B
B3
A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
B2
B1
CN
1
B10 B9
B8
B7
B6
B5
B4
A6
A5
A4
A3
A2
A1
A0
TB-A
A11
A10A9
A8
A7
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
24 VDC
B11
B10B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
A7
A8
A9
A10
A11
TB-A
A0
A1
A2
A3
A4
A5
A6
B4
B5
B6
B7
B8
B9
B10
CN
1
B2
A2
B1
A1
A3
A4
A5
A6
A7
A8
A9
A10B3
TB-B
5.6
kΩ/1
W
1
210
223
ø5.5
33.6
TB-BTB-A
CN
1C
N2
3295
Voltage conversion modelFor 16-point 200/240 VAC input module
Circuit configuration: Photocoupler
Voltage conversion modelFor 16-point input module
Circuit configuration: Resistor
PS-YSJ1000-1-PH2(Conversion of 200/240 VAC to 24 VDC)
StandardStandard
PS-YSJ1000-1-48(Resistor input)
StandardStandard
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
YOSHIDA ELECTRIC INDUSTRY CO.,LTD.
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
* The product comes with no terminal block.
Terminal block of existing PLC
To new PLC
Circuit diagramCircuit diagram
B1055Number of points per common (existing-PLC side) Signal output (new-PLC side)
Rated voltage
Rated current (input side)Photocoupler ON voltageCircuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
8
Connector200/240 VAC (existing-PLC side), 24 VDC (new-PLC side)10 mA100 VACPhotocouplerDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
Circuit diagramCircuit diagram
B1057Signal output (new-PLC side)
Rated voltage
Input impedanceCircuit congurationMounting schemeInsulation resistance (500 VDC megger)Dielectric strengthLighting impulse (1.2/50 μs)Vibration resistanceImpact resistance
Connector48 VDC (existing-PLC side), 24 VDC (new-PLC side)5.6 kΩResistorDirect mounting100 Mohm min. (to GND)2000 VAC for one minute (to GND)±4000 V, three times each (to GND)10 – 55 Hz, 0.5mm/p-p98m/S2 (10G)
SpecificationsSpecifications Existing PLC supportedExisting PLC supported
25 26
1. The applicable Adaptor models are rated at 2 A although the relays used are rated at 5 A.
2. Relays used are not of socket type, and cannot be replaced.
Pay due attention to working and operating conditions of the Adaptors prior to using them.
3. The durability of relays may vary signicantly depending on the switching conditions.
4. L-load actuated by a relay may cause reverse voltage to occur at switching off, resulting in generation of noises.
Be sure to use a surge absorption circuit when using L-load.
00 1 2 33 4 55 6 7 8 9 1010 30 100 250 500 1000
3
0.1
0.3
0.5
1
3
5
10
3050
5
10
30
50
300
500
100
Con
tact
cur
rent
(A)
No.
of s
witc
hing
cyc
les
(x 1
0)
Contact current (A)Contact voltage (V)
250 VAC/30 VDC resistance load
AC resistance load
DC resistance load
DC inductive load
250 VAC/30 VDC inductive load(COSψ = 0.4, L/R = 7 ms)
AC inductive loadCOSψ = 0.4
Max. switching capacity Durability curves
Operating Precautions Installation mount
Reference information regarding models having relays
1. Relay ratings
2. Switching performance
3. Notes
Applicable models: PS-YSJ1-RY1 • PS-YSJ1-RY2 • PS-YSJ2-RY1 • PS-YSJ1000-1-RY1PS-YSJ1000-0-RY2 • PS-YSJ1-RY1-S • PS-YSJ1-RY2-S • PS-YSJ2-RY1-S
The installation mount allows you to take advantage of the space in the depth direction of the control panel so as to install new PLCs without the need for occupying a space outside the control panel.
The lockable upper cover of the installation mount can be opened for smooth and easy installation and maintenance of PLC modules, and is durable to withstand up to 10 kg of weight.
Installation mounts custom-made depending on the size and number of PLCs from various manufactures are available on order.
The mounting space of existing PLC modules can be used to install the installation mount.
Place PLC Renewal Adaptors on the bottom of the installation
mount and t terminal blocks to the Adaptors.
Connect conversion cables to the Adaptors.
Place new PLC modules on the top of the installation mount and
plug the connector of the conversion cables into new modules.
1
2
3
Power consumption
200 mW/point
Max. permissible voltage
Approx. 110%
Releasevoltage
10% min.
Operatingvoltage
70% max.
Coil resistance
2.880Ω±10%
Rated current
8.3 mA
Rated voltage
24 VDC
Item
Resistance load
Contact resistance
Durability
Failure rate (P level)
Load
250 VAC/2 A, 24 VDC/2 A
100 Mohm max. (initial value)
Mechanical At least 20 x 106 switching cycles at a rate of 1800 cycles/h
ElectricalAt least 3 x 105 250 VAC/2 A resistance load cycles
At least 3 x 105 30 VDC/2 A resistance load cycles at a switching rate of 1800 cycles/h
5 VDC/10 mA
FeaturesFeatures
Installation procedureInstallation procedure
25 26
1. The applicable Adaptor models are rated at 2 A although the relays used are rated at 5 A.
2. Relays used are not of socket type, and cannot be replaced.
Pay due attention to working and operating conditions of the Adaptors prior to using them.
3. The durability of relays may vary signicantly depending on the switching conditions.
4. L-load actuated by a relay may cause reverse voltage to occur at switching off, resulting in generation of noises.
Be sure to use a surge absorption circuit when using L-load.
00 1 2 33 4 55 6 7 8 9 1010 30 100 250 500 1000
3
0.1
0.3
0.5
1
3
5
10
3050
5
10
30
50
300
500
100
Con
tact
cur
rent
(A)
No.
of s
witc
hing
cyc
les
(x 1
0)
Contact current (A)Contact voltage (V)
250 VAC/30 VDC resistance load
AC resistance load
DC resistance load
DC inductive load
250 VAC/30 VDC inductive load(COSψ = 0.4, L/R = 7 ms)
AC inductive loadCOSψ = 0.4
Max. switching capacity Durability curves
Operating Precautions Installation mount
Reference information regarding models having relays
1. Relay ratings
2. Switching performance
3. Notes
Applicable models: PS-YSJ1-RY1 • PS-YSJ1-RY2 • PS-YSJ2-RY1 • PS-YSJ1000-1-RY1 PS-YSJ1000-0-RY2 • PS-YSJ1-RY1-S • PS-YSJ1-RY2-S • PS-YSJ2-RY1-S
Place PLC Renewal adapters on the bottom of the installation
mount and fit terminal blocks to the adapters.
Connect conversion cables to the adapters.
Place new PLC modules on top of the installation mount and
plug the connector of the conversion cables into new modules.
1
2
3
Power consumption
200 mW/point
Max. permissible voltage
Approx. 110%
Releasevoltage
10% min.
Operatingvoltage
70% max.
Coil resistance
2.880Ω±10%
Rated current
8.3 mA
Rated voltage
24 VDC
Item
Resistance load
Contact resistance
Durability
Failure rate (P level)
Load
250 VAC/2 A, 24 VDC/2 A
100 Mohm max. (initial value)
Mechanical At least 20 x 106 switching cycles at a rate of 1800 cycles/h
ElectricalAt least 3 x 105 250 VAC/2 A resistance load cycles
At least 3 x 105 30 VDC/2 A resistance load cycles at a switching rate of 1800 cycles/h
5 VDC/10 mA
FeaturesFeatures
The installation mount allows you to take advantage of the space in the depth direction of the control panel so as to install new PLCs without the need for occupying a space outside the control panel.
The lockable upper cover of the installation mount can be opened for smooth and easy installation and maintenance of PLC modules, and is able to withstand up to 10 kg of weight.
Installation mounts are custom-made, depending on the size and number of PLCs from various manufacturers that are available at time of order.
The mounting space of existing PLC modules can be used to install the installation mount.
Installation procedureInstallation procedure
PLC Renewal Adaptor
UK-c
EK-ch
12.5 25 7.39
5.5
R2.
75
35
1
12.5 25 159
5.5
R2.
75
35
1
Accessories
For Yaskawa 2000/1000 I/O seriesFor Sharp JW/ZW series
Safety Precautions
Ver 1.12013.06-1KK-1
UK-b EK-b
UK-c EK-ec
Mounting Rail Rail End Cap
Item
Mounting Rail
Rail End Cap
End Bracket
Modelname
UK-c
EK-ch
UK-ec
EK-ec
UK-b
EK-b
ApplicableRail
—
—
UK-c
EK-ch
UK-c, EK-ch
UK-c, EK-ch
Length
1000, 1500, 2000
1000, 1500, 2000
—
—
—
—
No. of piecesper package
10
10
100
100
100
100
www.tohotechnology.comToho Technology Inc. 4809 North Ravenswood Avenue, Suite 113, Chicago, Illinois 60640 Tel: 773.583.7183
The products and specifications described in this manual or the content and presentation of the manual may be changed without notice to improve the product and/or the manual.
Please use appropriate current and voltage according to the manual.Our products were not designed or manufactured for use in devices or systems directly related to human life. Users who intend to
use the product described in this manual for special purposes must contact Toho Technology Inc, beforehand.If this product is to be involved a life and death situation or in a facility where failure may cause a serious accident, safety devices
MUST be installed to minimize the likelihood of any accident.
End Bracket
Recommended