system configuration
AReVA T&D
>> PIX up to 24 kV
Air-insulated switchgear with vacuum circuit-breaker
AIR INsULATeD swITCHgeAR
Delivery conditionsThe General Conditions of Delivery as amended shall apply.
IllustrationsThe illustrations are not binding.
>>Contents
INTRODUCTION
Overview 4
PRODUCT DesCRIPTION
Technical Description 6
Construction 6
Locks 8
sTANDARDs
Regulations, provisions and Standards 10
TeCHNICAL DesCRIPTION
Functional unit 12
HVX CB drawout module 13
Spring drive for HVX 14
Equipment 15
CVX drawout contactor module 16
CBX electromagnetic operating mechanisme 17
Equipment 17
UTX drawout disconnecting link module 18
MTX drawout VT‘s module 18
LTRI air switch disconnector 18
PRODUCT RANge
Product range 19
Equipment range 20
DesIgN DATA
PIX 12 23
PIX 17 24
PIX 24 25
Dimensions and layout 26
CAbLe CONNeCTIONs 27
ACCessORIes 28
sHIPPINg INFORMATION
Delivery, packaging 29
3
The PIX series switchgear panels are air-insulated, type-tested and metal-clad. AREVA switchgear technology satisfies the international requi-rements for energy distribution in medium-voltage grids and is espe-cially suited for application in: > Industry> Distributed Power> Oil & gas> Power plants> Shipbuilding> Infrastructure
The modular PIX switchgear covers a wide range of ratings for:> rated voltages of 12 kV, 17.5 kV,
24 kV> rated currents up to 4000 A> rated short-time currents
up to 40 kA> rated peak withstand currents
up to 100 kA.
Thanks to its modular design, the truck-type switchgear PIX is an especially compact switchgear system. By offering a switchgear technology with highly flexible equipment-fitting options, PIX provides a comprehensive, eco-nomical range of functional units for all switchgear-related require-ments.
Features> Air-insulated, metal-clad
switchgear - with three compartments - compartmentalization class PM> Loss of service continuity
category in accordance with IEC 62271-200
> LSC 2B> IAC qualification (optional) in
accordance with IEC 62271-200/ DIN EN 62271-200
> Truck-type switching devices - for vacuum circuit-breaker - for SF6 circuit-breaker> Truck-type design - of vacuum contactor - of metering truck - of isolating truck
Operator Safety> All operations are performed with
the front or door closed.> Make-proof earthing switch can
be checked via inspection glass.> Actuation of earthing switch with
anti-kickback device.> Reliable interlocks > Pressure relief directed upwards> Closed metal shutters with the
truck module in disconnected or outside position
> Voltage indicator for each phase
4
>>OverviewtH
e s
yste
M W
itH
tW
o s
Wit
CH
iNG
teC
HN
olo
Gie
s
Safe operation with the panels and doors closed
Easy operation and maintenance> Operation is simple and logical,
with clear status indicators for all functions.
> Manual or electrical control> The use of digital control and
protection equipment with self-testing and monitoring proce-dures.
Easy installation and access> PIX was designed to minimize
the space required, with access to all compartments via the front panel.
> Can be installed against a wall.> Connection of the cables via the
front is made easier by removing the separating plate between the cable and apparatus compart-ments. Optionally, the rear panel can be made removable.
> Rigid, self-supporting construc-tion.
5
EnvironmentPIX system has been conceived with due consideration of its impact on the environment:> In a factory certified to
ISO 14001> With a construction allowing
maximum recyclable compo-nents at the end of product life.
6
The PIX metal-clad switchboards are extensible on both sides and consist of modular functional units, linked by a busbar, and connected to the substation earth via an ear-thing bus.
The cubicles are subdivided by metal partitions into four separate compartments, including a low vol-tage compartment for the control and monitoring equipment.The three Medium Voltage com-partments; bus bar, equipment & cables, are fitted with an over-pressure release system, oriented towards the top of the unit inside of cubicle volume.
The fused switch-disconnectors are fixed type in the compartimen-ted unit.
Main module compartmentClosed off by a door, this compart-ment contains:> A withdrawable module, fitted
with a circuit breaker or con-tactor, which has two positions, “plugged in” or “disconnected/ test”.
All operations of the withdrawable module and its associated equip-ment can be carried out with the compartment door closed.
For modules fitted with vacuum circuit breakers, the movement can be motorised.
Withdrawable modules of the same type are interchangeable.
The connection between the with-drawable module, the busbar and the cable branches is made by means of withdrawable silver pla-ted contacts.
A 64-pin plug (Max.) connects the auxiliary circuits of the withdra-wable module to the low voltage compartment.
> For personnel safety, there are metallic shutters (1), installed in front of the spouts of the fixed “plug-in” contacts (2), which prevent access to the primary circuit, thus ensuring a protection when the withdrawable module is either in the “disconnected/test” position or removed from the compartment.
Once the withdrawable module has been removed, each shutter can be padlocked individually.
With the interlocking shutters option, the independant opening of the upper or lower shutter is only possible using a special tool (optionally supplied).
> An earthing device for the removable module, to the IEC standards, ensures earthing continuity during removal, either through rullers or through an optional plug.
An inspection window on the door, allows the position of the withdra-wable module to be clearly seen within the compartment.
The PIX system also offers, amongst the range of withdrawable modules, the functions of discon-necting link, voltage transformers and busbar earthing switch.
This compartment is fitted with mechanical locking devices in accordance with IEC standards, which are necessary to avoid any unsafe operations. (For details, see the chapter on locks).
>>Product descriptiona
ir iN
su
late
d s
Wit
CH
Gea
rs
Main module compartment.
Operating panel
7
Cable compartmentNormally closed with a bolted panel, accessible from the front panel, and with a removable hori-zontal panel between the cable & main module compartment, this
design is made for ease of assem-bly and on-site testing of cables and accessories.
As an option, and depending on the installation of switchboard cho-sen, the rear panel can be made removable, to further improve access.
This compartment contains:> The connections to the power
cables, up to 6 x 630 mm2 per phase, with a choice of bottom plate (for details, see chapter on cable connections).
> The cable earthing switch is operated from the front of the cubicle by means of a removable lever.
Its position is visible from the front panel, through the inspec-tion window in the cable panel.
> Current transformers, with DIN dimensions, are fitted at the rear of the cubicle.
> The voltage transformers, fitted at the front of the compartment, are either fixed - with or without fuses, or removable with fuses.
> A metallic cable duct, located on the right-hand lateral part, guides the low voltage conductors into the control/command compart-ment safely.
At the front, upper section of this compartment, is the access to the earthing switch controls, along with its mimic diagram and VPIS type voltage indicators (IEC 61958).
VDS type voltage indicators(IEC 612345) can be offered as an option.
Details of the interlocks are given in the next chapter.
Busbar compartmentLocated in the upper, rear of the unit, this compartment is accessi-ble via the top or front panel of the cubicle, after removing the parti-tions, which separate it from the switchgear compartment.The bus bar consists of flat copper with rounded edges. The rated cur-rent will determine the number of bars to be mounted in parallel.The bus bar is linked and suppor-ted by solid connections to the spouts.
Optionally, this compartment can be fitted with:> Segregations made of insulating
materials, resistant to pressure, mounted between each cubicle.
> Insulation of the bus bars and branch connections.
> Fixed voltage transformers, without fuses.
> An earthing switch.
Low voltage compartmentThis compartment contains all the secondary circuit functions for control, measurement, protection, monitoring, communication and other associated systems.
This independent compartment, is a separate assembly, supplied fully assembled and tested.
Busbar compartment
Low voltage compartment standard.HVX compartment without insula-ting protection plate
Cable connection compartment
8
LocksThe operation of PIX is designed to be completely safe. All the ope-rations listed below are carried out from the front panel, with the door and panels closed.> Connect or disconnect the with-
drawable module. > Re-load the spring mechanism.> Mechanically close or open the
circuit breaker or switch-discon-nector.
> Open or close the earthing switch. Access to the withdra-wable module compartment requires the use of a specialised handle and key.
The interlocks were designed with this operational ideology in mind and add to the security of the system by making it impossi-ble to make unsafe operations.
Actions Status of elements involved
Plugging in the module
Basic locking devices
- LV socket connected- Circuit breaker open- Earthing switch open
Optional locking devices
- Module compartment access door closed
Closing the circuit breaker/contactor
Closing the earthing switch
Access to the cable compartment
Opening of the earthing switch
- Module completely plugged in, or plugged out/test position
- Plug-in lever removed
- Module plugged in/out/test posi-tion or removed
- Earthing switch closed
- Cable compartment panel closed
Access to the withdrawable module-compartment
Partial re-opening of the earthingswitch for cable testing
Opening of the shutters
(Reminder: requires the use of aspecific key and handle)
- Module in disconnected plugged-out/test
- Is not possible to put the breakermodule into the panel again whenthe earthing switch is in this position
- By the withdrawable module action
- With specific tool.
Basic locking devices Optional locking devices
Locking device using padlocks
Locking devices (specific)
- Shutters- Earthing switch access (in open
or closed position)- No access to operate the drawout
module
- ON/OFF Buttons - Circuit breaker
Locking device using fixed locks
Locking device by electromagneticcoil
- The door of the withdrawable module
- Earthing switch, either in open or closed position
- Module in plugged out position
- Earthing switch, in open position- Disconnect link module (UTX)
Other safety equipment
9
PIX IN DeTAIL
1
13
12
11
10
9
8
7
2
3
4
5
6
1 LV compartment standard2 Circuit breaker3 Switchgear compartment door4 Earthing switch operating
mechanism5 Voltage presence indicator6 E.S. mimic digram7 Cable compartment panel8 Voltage transformer9 Current transformer10 Cable connection11 Earthing switch12 Metal shutter for cable13 Spouts14 Metal shutter for busbar15 Busbar
Operating panel Earthing switch indicator
Earthing switch drive
10
CeRTIFIeD sAFeTy DUe TO TesTs
The PIX panels were developed on the basis of international standards (IEC) and validated for type tests which are performed in acknow-ledged laboratories.
>>standardsRegulations, provisions and standards
Cer
tifi
ed s
afe
ty d
ue
to t
ests
APPLIeD sTANDARDs
Series PIX switchgear units with vacuum switching devices are> metal enclosed; Loss of service continuity
category in accordance with IEC 62271-200: LSC 2B-PM
> type-tested> optional: tested for internal faults
(qualification IAC)> dimensioned for indoor instal-
lation
PIX switchgear units meet the following standards and regulations:
Designation IEC standard EN standard
Switchgear IEC 62271-1
IEC 62271-200 EN 62271-200
Circuit-breaker IEC 62271-100 EN 62271-100
Vacuum contactor IEC 60470 EN 60470
Earthing switch IEC 62271-102 EN 62271-102
Isolating truck IEC 62271-102 EN 62271-102
Current transformers IEC 60044-1 EN 60044-1
Voltage transformers IEC 60044-2 EN 60044-2
Voltage Detecting SystemsIEC 61243-5 EN 61 243-5
IEC 61958 EN 61958
Protection against accidental contact, foreign bodies and water
IEC 60529 EN 60529
Erection IEC 61936-1 HD 637 S1
Operation of electrical equipment - EN 50110-1
Switch fuse combination IEC 60265-1 EN 60265-1
11
Operating conditions for interior use, in accordance with IEC 60694
Ambient temperature
Ambient air
- + 40°C- maxi + 55°C with corresponding under-rating current- + 35°C on average over a 24 hour period- - 5°C minimum
- No impurities due to dust, flammable/corrosive gases & vapours, smoke or salt.
Humidity
Altitude
Vibration
- Average relative humidity over a 24 hour period: 95%- Average steam pressure over a 24 hour period: Max. 2.2 kPa- Average relative humidity over a 1 month period: 90%- Average steam pressure over a 1 month period: Max. 1.8 kPa
- Up to 1,000 m above sea level, corresponding to atmosphericconditions of: 1013 hPa, + 20 °C, 11g/m3 water.
- Above 1,000 m, a derating factor is applied, please contact us for details.
- Negligible- For particular conditions, please contact us.
OPeRATINg CONDITIONs
Standard degree of protection of theexternal enclosure: IP 3XOptionally, there is the possibility ofvarious IP, ratings in accordance withthe table below.
Meaning for the protection of equipment
Elements of code IP
Protection against water ingress withharmful effects
1st element
234X
> = 12.5 mm> = 2.5 mm> = 1 mmNot defined
Protection against access to the dangerous parts by means of tools
2nd element
Meaning for the protection ofpeople
Additional element
Not used element coveredby 1st element
01
2
X
Not protectedVertical dripping waterDripping water with15° inclinationNot defined
C
D
X
D = 2.5 mmL = 100 mmD = 1 mmL = 100 mmNot defined
PROTeCTION DegRee
12
>>Technical datate
CH
NiC
al
iNfo
rM
ati
oN
s
Designation
Reference standards
Rated voltage kV rms
Power frequency withstand voltage 50 Hz 1 min
Impulse withstand voltage 1,2 / 50 micro sec
to earth and between phases kV rms
on the isolating distance kV rms
Rated frequency
Short time current
to earth and between phases
on the isolating distance
kV peak
kV peak
Hz
Rated current
1 sec withstand (2)
3 sec withstand (2) (1)
kA rms
kA rms
Peak withstand kA rms
PIX 12 PIX 17
IEC 60298
12
IEC 60298
17.5
PIX 24
IEC 60298
24
28 38
32 45
50
60
75
85
95
110
50 / 60 50 / 60
125
145
50 / 60
25 / 31.5 / 40
25/ 31.5 / 40
25 / 31.5 /40
25 / 31.5 / 40
63 / 80 / 100 63 / 80 / 100
16 / 25 / 31.5
16 /25 / 31.5
40 / 63 / 80
Busbar with natural ventilation
Busbar with forced ventilation
A
A
Functions Disconnect link
Functions CB with natural ventilation
A
A rms
Functions CB with forced ventilation
Functions SWD
A rms
A rms
Functions Air SWD + fuses
Functions Contactor
A rms
A rms
Up to 3150
Up to 4000
Up to 3150
Up to 4000
Up to 3150
Up to 3150
Up to 3150
Up to 3150
Up to 2500
Up to 2500
Up to 2500
Up to 4000
630
Up to 4000
630
400
200-400
400
630
400
Internal arc withstand
Earthing switch making capacity (2)
Earthing switch endurance
kA
kA peak
number of making operation
Degree of protection
mechanical (C/O)
external enclosure standard
open door without withdrawable module
Up to 40 kA - 1 sec
63 / 80 / 100
Up to 40 kA - 1sec
63 / 80 / 100
2 2
Up to 31.5 kA - 1sec
40 / 63 / 80
2
1000 1000
IP 3X
IP 2X
IP 3X
IP 2X
1000
IP 3X
IP 2X
Approximate heat dissipation
Force on floor (without cubicle weight)
Functions CB Ir = 800A W
Functions CB daN(1) Earthing switch limited 40 kA - 1sec(2) For SWD and SWD + fuses functions
Short time current
1 sec withstand kA rms
650 650
750 750
650
750
16 / 25 16 / 25 16 / 25
Earthing switch making capacity
peak withstand kA peak
kA peak
40 / 63
40 / 63
40 / 63
40 / 63
40 / 63
40 / 63
FUNCTIONAL UNIT
For 50 kA, 5000 A, please refer to PIX-H documentation or contact us.
13
HVX DRAwOUT CIRCUIT bReAkeR MODULe - CHARACTeRIsTICs
For the cubicles
Designation
Reference standards
Rated voltage
Rated current
Rated breaking capacity
kV
A rms
short circuit current kA rms
cable charging current
line charging current
A
A
single capacitor bank
no load transformer
A
A
Rated making capacity
Rated operating time
kA peak
opening
breaking
ms
ms
PIX 12 PIX 17
HVX 12
IEC
HVX 17
IEC
PIX 24
HVX 24
IEC
12
Up to 3150
17.5
Up to 3150
16/25/31.5/40 25/31.5/40
24
Up to 2500
16/25/31.5
25
10
31.5
10
400
10
400
10
31.5
40/63/80/100 63/80/100
40-47
55-62
40-47
55-62
40/63/80
40-47
55-62
Rated operating sequence
arcing
closing
ms
ms
Endurance
mechanical (C/O) for switching chamber
2-15
50-58
2-15
50-58
O-3min-CO-3min-CO
CO-15s-CO
O-3min-CO-3min-CO
CO-15s-CO
2-15
50-58
O-3min-CO-3min-CO
CO-15s-CO
O-0.3s-CO-3min-CO
O-0.3s-CO-15s-CO
O-0.3s-CO-3min-CO
O-0.3s-CO-15s-CO
30 000 30 000
O-0.3s-CO-3min-CO
O-0.3s-CO-15s-CO
30 000
mechanical (C/O) for mechanism
electrical (C/O at In up to3150 A)
10 000
10 000
10 000
10 000
10 000
10 000
14
Designation
Reference standards
Rated supply voltage (1)
Rated frequency
Reset motor
V
Hz
Voltage variation range % of Un
Shunt opening coil
Power consumption (maxi)
Starting current
W / VA
A
Reset time s
Under voltage opening coil
Voltage variation range
Power consumption (maxi)
% of Un
W / VA
Minimum impulse duration ms
FH2-01 (hand) / FK2-01 (motor)
IEC
DC
IEC
AC
24-48-60-110-125-220 120-230
50/60
85 to 110 85 to 110
100 100
8-12 8-12
70 to 110
≤ 250
70 to 110
≤ 250
50 50
Shunt closing coil
Voltage range for closing
Voltage range for tripping
% of Un
% of Un
Power consumption (maxi) W/VA
Auxiliary contacts
Rated current
Power consumption maxi
% of Un
W/VA
Rated current A
>85
35 to 0
>85
35 to 0
10 10
85 to 110
≤250
85 to 110
≤250
15 15
Breaking capacity 48V (L/R 10ms)
Breaking capacity 125V (L/R 10ms)
A
A
Breaking capacity 220V (L/R 10ms)
Breaking capacity 120 or 230 Vdc
A
A
10
4
-
-
2
-
-
10
HVX sPRINg OPeRATINg MeCHANIsM
(1) No 125 Vdc for reset motor - No 220 Vdc and 120 Vac for under voltage opening coil.
15
���������������
0
HVX up to 2000 A HVX > 2000 A
FH2-01 (hand)
Manual opening and closing
Basic
•CB Position indicators
Spring charging motor
Spring position indicator
Shunt trip coil
•
•
Second shunt trip coil
CT operated release
Undervoltage shunt tripping coil
Closing coil
Operation counter
Anti-pumping relay
Free auxiliary contacts
•
CB position 2NO / 2NC •
FK2-01 (motor)
Optional Basic
•Optional
••
•••
•••
•
•••
••
•
•
3NO / 4 NC
Spring charged position 2NO / 1NC ••
••
eqUIPMeNT
For more information refer to HVX documentation t&d bprob/hvxb-24 kv/uke/pdb/04.01/ger/2854
16
CVX drawout contactor module CVX drawout contactor module on truck
For the cubicles
Designation
Contactor designation
Reference standards
Category
Rated voltage
Rated current
kV
A rms
Maximum motor rated current
Rated breaking capacity
A
short circuit current with fuses
short circuit current without fuses
kA rms
kA rms
Rated making capacity with fuses
Rated making capacity without fuses
Rated operating time
single capacitor bank A
kA peak
kA peak
PIX 12 PIX 12
CVX 07
CBX
CVX 12
CBX
IEC
AC3 - AC4
IEC
AC3 - AC4
7.2
400
12
400
320 320
40
6
40
4
280
100
280
100
15 10
opening with d.c. magnetic holding control
opening with a.c. magnetic holding control
ms
ms
opening with mechanical latch control
closing
ms
ms
Rated operating sequence number
Endurance
per hour
mechanical with magnetic holding (C/O)
electrical with mechanical latch (C/O)
60 to 100
90 to 120
60 to 100
90 to 120
20 to 30
60 to 100
20 to 30
60 to 100
1200 1200
3 000 000
200 000
3 000 000
200 000
electrical (C/O at 400 A)
electrical (C/O at 250 A)
electrical (breaking at Icc 3.2 kA)
electrical (making at Icc 4 kA)
500 000
1 000 000
500 000
1 000 000
25
100
25
100
CVX DRAwOUT CONTACTOR MODULe - CHARACTeRIsTICs
17
Designation
Reference standards
Rated supply voltage
Rated frequency
Magnetic holding control circuit
V
Hz
Voltage range for closing % of Un
Mechanical latch control circuit
Voltage range for opening
Power consumption on closing
% of Un
W / VA
Power consumption on holding W / VA
Voltage variation range
Power consumption on closing
% of Un
W / VA
Power consumption on opening
Minimum impulse duration
W
ms
IEC
DC
IEC
AC
24-48-60-110-125-220 120-230
50/60
> 85 > 85
75 to 10
615
75 to 10
615
150 150
70 to 110
615
85 to 110
615
240
20
240
20
Auxiliary contacts:
Rated current A
Breaking capacity 48 Vdc (L/R 10 ms)
Breaking capacity 220Vdc (L/R 20 ms)
15 15
CbX eLeCTROMAgNeTIC OPeRATINg MeCHANIsMs
Operating mechanism Magnetic holding
Manual opening
Contactor Position indicators •Magnetic holding coil
Shunt trip coil
Closing coil
Operation counter
•
•Anti-pumping relay
Free auxiliary contacts
•
Contactor position 3 NO / 3 NC
Fuse position 1 O/C
••
Mechanical latch
••
••••
••
eqUIPMeNT
For more information refer to CBX documentation
18
UTX DRAwOUT DIsCONNeCTINg LINk MODULe
Disconnect link 12 kV Disconnect link 24 kV
MTX drawout VT‘s moduls LTRI Air Switch-Disconnector
MTX DRAwOUT VT’s MODULe
LTRI AIR swITCH-DIsCONNeCTOR
Position HVX - UTX - MTX
Plugged in and test/unplugged
Basic
Plugged in
1 O/C (reverse)
4 O/C (reverse)
•
1 N/C •
Unplugged/test
1 N/C + 1 N/O
2 N/C
1 NC •1 N/C + 1 N/O
2 N/C
CVX
Optional Basic Optional
•
••
••
AUXILIARy CONTACTs FOR wITHDRAwAbLe MODULe
Position Basic
Close/Open 1 O/C (reverse)
Closed 3 N/C
•
Opened 3 N/C
Optional
••
AUXILIARy CONTACTs FOR eARTHINg swITCH
19
>>Range of equipment
PRODUCT RANge
Incoming/Outgoing with circuit breaker
Incoming/Outgoing with circuit breaker
+ fixed VT’s
Incoming/Outgoing with circuit breaker withdrawable cable VT’s with removable
fuses
Outgoing with disconnect link
Contactor outgoing Switch disconnector and fuses outgoing
Bus section with circuit breaker
Bus riser withtransformers
Busbar with voltage transformer on
the top
Busbar with earthing switch on the top
Direct incoming Busbar voltagemetering with
earthing switch
Busbar voltagemetering
Busbar current metering
20
(1)
(1)
eqUIPMeNT RANge
> Incoming or outgoing unit with circuit breaker up to 2000 A.
On request:- VT’s with fuses- Withdrawable cable VT’s with removable fuses- Fixed VT’s without fuses (1)
- Surge arresters
> Incoming or outgoing unit with circuit breaker 2500 to 3150 A.
On request:- VT’s with fuses- Withdrawable cable VT’s with removable fuses- Fixed VT’s without fuses (1)
- Surge arresters
> Outgoing unit with contactor and fuses 200, 400 A.
On request:- Surge arresters
21
(1)
(1)
(1)
(2)
(1)
(2)
> Bus section unit with circuit breaker up to 2000 A
On request:- Busbar earthing switch (1)
> Bus section unit circuit breaker 2500 to 3150 A
On request:- Busbar earthing switch (1)
> Bus riser unit up to 2000 A.
On request:- Withdrawable VT’s module with
fuses (1).- Current transformers (2)
> Bus riser unit 2500 A to 3150 A.
On request:- Withdrawable VT’s module with
fuses (1).- Current transformers (2)
22
> Direct incoming unit up to 3150 A.
On request:- Surge arresters- Fixed VT’s with fuses- Fixed VT’s without fuses- VT’s removable fuses.
> Busbar voltage metering On request:- Busbar earthing switch (1)
> Outgoing unit with switch disconnector and fuses
On request:- Current transformers
> Busbar voltage transformers without fuses on the top
> Busbar earthing switch on the top
(1)
23
>>Design data
PIX 12
Min. 100 C
A1
A2A
B
1500 Min.
Min
. 31
30
1000
Doo
r 25
00
383
C
492
75.575
.5
B
B1 B1
74
40
28.528.5
50
200
126
=
75.5
35
=
440
35
C1
4
1
3
2
ø 12.5
Width 650 - 800 mmB = 185 - 210
B1 B1
B
C
383
75.5
75.5
492
50
28.528.5
126
200
74
40
440
35
C1
35
==
1
3
2
ø 12.5
Width 1000 mmB1 = 254
A: 2130 2230
A1:
A2:
530
2730*
630
C:
C1:
1405/1605 (1) (2)
100/300
2330
730
* Height with forced cooling or duct for gas evacuation.
Functions PIX 12 up to 40 kA 4000A
Icc(kA)
In(A)
≤ 31.5
B (width)
Incoming or outgoing
CB
Disconnect link
Bus section
≤ 1250 650
1600 800
Direct incoming
2000
≥ 2500
1000
1000
≤ 1250 650
Bus riser
1600
2000
800
800
≥ 2500
1250
1000
650
40
Approximate
weight (kg)
800 720
650 (1)
800 770
1000
1000
770
820
800
650 (1)
650
800
800
700
750
1000
650
750
600
Bus riser disconnect link
Busbar voltage metering
1600
2000
800
800
≥ 2500 1000
650
Switch disconnectorand fuses outgoing
Contactor
650
650
800
800
650
700
1000
650
700
600
-
650
600
700
Dimensions in mm - (1) Depth 1605 for internal arc withstand 40 kA with width 650 mm - (2) Depth 1605 for 2 CT/phaseFor seismic and arrangement on skid please contact us.
24
PIX 17
Mini 100 C
A1
A2A
B
1500 Mini
Min
i 320
0
1000
Doo
r 25
00
435
C
540
75.575
.5
B
74
40
28.528.5
50
200
126
75.5
35
440
35
C1
B1B1==
4
1
3
2
ø 12.5
Width 750 mmB = 210
435
C
540
75.575
.5
B
74
40
28.528.5
50
200
126
35
440
35
C1
B1 B1==
1
3
2
ø 12.5
Width 1000 mmB1 = 254
Functions PIX 17 up to 40 kA 4000A
Icc(kA)
In(A)
≤ 25
B (width)
Incoming or outgoing
CB
Disconnect link
Bus section
≤ 1600 750
2000
≥ 2500
750
1000
Direct incoming
Bus riser
≤ 1600
2000
750
750
≥ 2500 1000
Bus riser disconnect link
Busbar voltage metering
1600
2000
750
750
≥ 2500 1000
750
31.5-40
Approximate
weight (kg)
750 (1) 850
750 (1)
1000
850
850
750 (1)
750 (1)
730
780
1000 780
750
750
680
730
1000
750
730
650
Switch disconnectorand fuses outgoing 750 - 650
A: 2200 2300
A1:
A2:
600
2800*
700
C:
C1:
1505/1605 (1) (2)
100/200
2400
800
Dimensions in mm - (1) Depth 1605 for internal arc withstand 40 kA - (2) Depth 1605 for 2 CT/phaseFor seismic and arrangement on skid please contact us.
* Up to 2800 with forced cooling or duct for gas evacuation.
25
PIX 24
Mini 100 C
A1
A
B
1500 Mini
Min
i 333
0
1000
Doo
r 25
00
433
C
542
75.575
.5
B
74
40
28.528.5
50
200
126
75.5
35
440
35
C1
B1B1==
4
1
3
2
ø 12.5
Width 800 mmB = 210
433
C
542
75.575
.5
B
74
40
28.528.5
50
200
126
75.5
35
440
35
C1
B1B1==
4
1
3
2
ø 12.5
Width 1000 mmB1 = 254
Functions PIX 24 up to 31.5 kA 2500A
Icc(kA)
In(A)
≤ 25
B (Width)
Incoming or outgoing
CB
Disconnect link
Bus section
≤ 1600 800
2000
≥ 2500
1000
1000
Direct incoming
Bus riser
≤ 1600
2000
800
800
2500 1000
Bus riser disconnect link
Busbar voltage metering
≤ 1600
2000
800
1000
2500 1000
800
31.5-40
Approximate
weight (kg)
800 820
1000
1000
870
870
800
800
750
800
1000 800
800
800
700
750
1000
800
750
700
Switch disconnectorand fuses outgoing 800 - 700
A: 2330 2430
A1:
A2:
530
1605
630
C: 100
2530*
730
Dimensions in mmFor seismic and arrangement on skid please contact us.
* Height: = 2730 with duct for gas evacuation.= 2890 with deflectors for internal arc withstanding.
26
FLOOR PLAN
Detail A
groundbus
1m
100
670 77
0
720 82
0
770 87
0
Front Front Front
Cubicle Cubicle Cubicle
100 100
2 m
m m
ax.
6 m
m m
ax.
groundbus
Cubicles
2 mm/m max. and6 mm/total length of switchboard
PIX 12 PIX 17 PIX 24
27
>>Cable connections
The manufacturer’s instructions for the ends of the cables must be followed.
Adjustment 50 mm +5 -5
L (c
able
end
)
L1 m
axi
X L (c
able
end
)
L3 m
axi
108
L4 m
axi
12
L2 m
axi
X
Cable glands in upper position Cable glands in lower position
Assembly with DIN clampsCable 95 mm2.
Assembly with DIN clampsCables 300 - 630 mm2.
PIX 12 PIX 17
X
L1
430
390
460
420
L2
L3
L4
440
290
470
320
410 440
PIX 24
555
515
565
415
495
28
>>Accessories
Designation Illustration
Handle for opening and closing the front door
Double-bit key for the front door
Double-bit key for the low-voltage compartment
Crank to charge the circuit-breaker‘s energy-storing device
Operating rod to switch the circuit-breaker on and off
Designation To be used for: Rated value Connector design
Illustration
Operating lever for earthing switch
Cable feeder
Short circuit current ≤ 31.5 kA
square
square
Short circuit current 40 kA
hexagonal
Busbar
Short circuit current ≤ 31.5 kA
square
Short circuit current 40 kA
hexagonal
Crank for truck
Truck HVX/UTX/MTX
Rated current Ir < 2500 A
hexagonal
Truck HVX/UTX
Rated current Ir ≥ 2500 A
square
Motor drive - -
29
>>shipping instructions
DeLIVeRy
DeliveryThe cubicles, which make up the switchboard are delivered individu-ally, ready for assembly.The connection should be carried out on-site.
Packaging> For transportation by lorry: The product is fixed to a wooden
pallet and protected by plastic cover.
The front panel is protected by polystyrene panels.
> For transportation by sea: The product is covered with a
plastic heat welded cover, with desiccant materials, then instal-led into a wooden case.
> For transportation by air: The product is covered with a
plastic heat welded cover, with desiccant materials, then instal-led into a wooden case.
30
Notes:
AREVA Energietechnik GmbH, Sachsenwerk MittelspannungRathenaustraße 2 · D-93055 Regensburg · P.O.B. 10 01 55 · D-93001 Regensburg
Phone +49 (0)9 41/46 20-0 · Fax +49 (0)9 41/46 20-4 18
AReVA T&D worldwide Contact Centre:http://www.areva-td.com/contactcentre/Tel.: +44 (0) 1785 250 070
www.areva-td.com
AR
EV
A E
nerg
iete
chni
k G
mb
H -
Sac
hsen
wer
k M
itte
lsp
annu
ng -
AG
SIE
XX
XX
-01-
1008
- ©
- A
RE
VA
- 2
008.
AR
EV
A,
the
AR
EV
A lo
go a
nd a
ny a
ltern
ativ
e ve
rsio
n th
ereo
f ar
e tr
adem
arks
and
ser
vice
mar
ks o
f A
RE
VA
The
othe
r na
mes
men
tione
d,
regi
ster
ed o
r no
t, a
re t
he p
rop
erty
of
thei
r re
spec
tive
com
pan
ies
- 38
9191
982
RC
S P
aris
- C
reat
ion:
SC
HR
EM
L W
erb
eage
ntur
Gm
bH
, R
egen
sbur
g -
Prin
ted
in G
erm
any
Recommended