PANTEX Lattice Girders
2
3
Introduction .................................................................................................................. 3
Fields of Application ..................................................................................................... 4
Main Advantages .......................................................................................................... 4
System Description ...................................................................................................... 4
System Components .................................................................................................... 5
Specifications ............................................................................................................... 5
Accessories .................................................................................................................. 6
Further References ....................................................................................................... 6
Contents
PANTEX Lattice Girders have been developed for special demands in the field of Tunneling. The PANTEX system has been extensively tested and used successfully for numerous tunnel projects throughout the world.
PANTEX Lattice Girders ensure an immediate support in the open span area. Contrary to standard solid-web girders, PANTEX Lattice Girders are entirely integrated in the shotcrete lining; porous zones and shotcrete spray shadows are avoided.
The load-bearing capacity of PANTEX Lattice Girders has been investigated with various loading tests and by numerical analysis. Flexibility regarding geometry and bearing capacity characterize this passive support system for underground applications.
Introduction
4
x
y
S 1
B
H
eS
3
S2
H1
■ Immediate support in the excavation area
■ Utilization as a true-to-form template for shotcrete application
■ Easy and quick assembling, simple handling
■ Optimum bond and interconnection with the shotcrete lining
■ Simple adjustment and shaping to the excavation geometry
■ Ideal bearing for spiles and lagging boards
■ Spiles may be installed both above or through the lattice girders
System Description
■ Load-bearing elements according to the particular demands in Tunneling
■ Spatial 3 or 4 bar girder construction, connected via stiffening elements
■ 3-bar girder: single bar either at the excavation or ground side, depending on the application
■ 4-bar girder: application as wallplate beam or stiff cross girder
■ Reduction of girder buckling lengths by stiffeners
Fields of Application
■ Passive support system for the excavated cross section
■ Profile template for the excavation geometry
■ Bearing for pre-support elements
Main Advantages
■ Assembly of the full girder profile by connecting single girder elements
■ Load transmission even before shotcrete application
■ Integral part of the shotcrete lining reinforcement
■ Proven bond according to the design principles of reinforced concrete
Stiffener (spider)Bar S2
Bar S3
5
Aussteifungselement (Spinne)
x
y
S 1
B
H
eS
3
S2
30 - 50
H1
Gurtstab S2
Gurtstab S3
System Components
Specifications
No. Designation 1) H1 S1 S2 S3 Weight 2) H B A Wx 3) Ix Article No. 4)
[#] [PS1-S3-S2] [mm] [mm] [mm] [mm] [kg/m] [mm] [mm] [cm²] [cm³] [cm4] [---]1 P50-20-25
50 10
25 20 10.2 95
100
11.19 28 148 14102025XXXX2 P50-20-30 30 20 11.9 100 13.35 38 193 14102030XXXX3 P50-20-36 36 20 14.3 106 16.46 42 246 14102036XXXX4 P50-25-30 30 25 14.7 105 16.89 42 255 14102530XXXX5 P50-25-36 36 25 17.1 111 20.00 58 336 14102536XXXX6 P50-30-36 36 30 20.5 116 24.32 64 424 14103036XXXX7 P70-20-25
70 10
25 20 10.4 115
140
11.19 37 239 14122025XXXX8 P70-20-30 30 20 12.1 120 13.35 51 306 14122030XXXX9 P70-20-36 36 20 14.5 126 16.46 54 383 14122036XXXX10 P70-25-30 30 25 14.9 125 16.89 56 398 14122530XXXX11 P70-25-36 36 25 17.3 131 20.00 77 517 14122536XXXX12 P70-30-36 36 30 20.7 136 24.32 83 644 14123036XXXX13 P95-20-25
95 10
25 20 10.8 140
180
11.19 49 384 14142025XXXX14 P95-20-30 30 20 12.5 145 13.35 66 485 14142030XXXX15 P95-20-36 36 20 14.9 151 16.46 69 598 14142036XXXX16 P95-25-30 30 25 15.3 150 16.89 72 625 14142530XXXX17 P95-25-36 36 25 17.7 156 20.00 100 799 14142536XXXX18 P95-30-36 36 30 21.1 161 24.32 107 986 14143036XXXX19 P115-20-25
115 12
25 20 11.0 160
220
11.19 58 525 14162025XXXX20 P115-20-30 30 20 12.7 165 13.35 78 658 14162030XXXX21 P115-20-36 36 20 15.1 171 16.46 82 804 14162036XXXX22 P115-25-30 30 25 15.5 170 16.89 86 842 14162530XXXX23 P115-25-36 36 25 17.9 176 20.00 120 1,070 14162536XXXX24 P115-30-36 36 30 21.3 181 24.32 126 1,312 14163036XXXX25 P130-20-25
130 12
25 20 11.2 175
220
11.19 66 644 14182025XXXX26 P130-20-30 30 20 12.9 180 13.35 87 805 14182030XXXX27 P130-20-36 36 20 15.3 186 16.46 91 980 14182036XXXX28 P130-25-30 30 25 15.7 185 16.89 96 1,027 14182530XXXX29 P130-25-36 36 25 18.1 191 20.00 134 1,299 14182536XXXX30 P130-30-36 36 30 21.5 196 24.32 141 1,589 14183036XXXX
1) Designation: PH1-S3-S2, e.g. P130-20-30 ; 2) Weight including stiffeners (average values)3) Quotient moment of inertia and maximum distance from the neutral axis to the outer fiber ; 4) „XXXX“ … project-specific designation
Girder Bars ■ 3-bar girders: 2 + 1 bars
■ 4-bar girders: 2 + 2 bars
■ Smooth or ribbed reinforcing steel B 500 B (DIN 488-1) or B 550 B (ÖNORM B 4707)
■ High strength and great deformability
Stiffeners ■ Smooth or ribbed reinforcing steel
■ Steel grade B 500 B or higher
■ 4 bar stiffeners in one part ensure optimum bearing capacity
Connections ■ Angle or alternative flat steel connection plates
■ Steel grade S 235 (EN 10025) or higher
■ Bolts: standard grade 8.8 (EN ISO 898-1)
■ Slotted bolt or customized connections available upon request
■ Base plates: standard or elephant foot version
■ Special connections available upon request
3-bar girder
6
Accessories
Angle connection plates and base plates
Further References
4-bar girder
■ 4-bar girders can be used as wallplate beams for crown drives
■ Installation of 90° axial rotated 4-bar girders in the longitudinal direction
■ Wallplate beams serve as bearing and profile template for installation of the girder arch
■ Bend-proof frontal connection allows free crown advancing
■ At the same time, wallplate beams are considered as statically effective reinforcement for the foot beam
■ Ongoing internal factory production control
■ External supervision of the manufacturing process
■ Certificate of conformity No. 11 7165-1/1, MPA NRW, dating 2012-05-24, for the building product DSI lattice girders type PANTEX / 3 bars
No. Designation 1) H1 S1 S2 Weight 2) H B A Wx Wy Article No. 3)
[#] [PH1-S2] [mm] [mm] [mm] [kg/m] [mm] [mm] [cm²] [cm3] [cm3] [---]1 P100-20
50 10
20 12.7 140
100
12.57 65 41 14200020XXXX2 P100-25 25 14.3 150 19.63 103 56 14200025XXXX3 P100-30 30 19.4 160 28.27 151 72 14200030XXXX4 P100-36 36 26.7 172 40.72 222 88 14200036XXXX5 P140-20
75 10
20 13.1 190
140
12.57 96 65 14220020XXXX6 P140-25 25 18.5 200 19.63 151 94 14220025XXXX7 P140-30 30 25.3 210 28.27 219 124 14220030XXXX8 P140-36 36 35.1 222 40.72 319 161 14220036XXXX9 P190-20
95 10
20 13.9 230
180
12.57 121 90 14240020XXXX10 P190-25 25 19,3 240 19.63 190 132 14240025XXXX11 P190-30 30 26.1 250 28.27 275 178 14240030XXXX12 P190-36 36 35.9 262 40.72 399 237 14240036XXXX13 P230-20
115 10
20 14.3 270
220
12.57 146 114 14260020XXXX14 P230-25 25 19.7 280 19.63 228 170 14260025XXXX15 P230-30 30 26.5 290 28.27 330 233 14260030XXXX16 P230-36 36 36.3 302 40.72 479 316 14260036XXXX17 P260-20
130 10
20 14.7 300
220
12.57 164 114 14280020XXXX18 P260-25 25 20.1 310 19.63 258 170 14280025XXXX19 P260-30 30 26.9 320 28.27 372 233 14280030XXXX20 P260-36 36 36.7 332 40.72 539 316 14280036XXXX
Type Angle connections Foot plates
DesignationAngle steel(B x L x t) 1) Cut length G 2) Size
(B x L x t)G
[PH1] [mm] [mm] [kg] [mm] [kg]
P50
80 x 120 x 10
1101.7
100 x 100 x 10 0.81.7
P70 1382.1
140 x 140 x 10 1.62.1 2.1
P95 1652.5
145 x 180 x 10 2.12.5 2.5
P115 2003.0
165 x 220 x 10 2.93.0 3.0
P130 2103.2
180 x 220 x 10 3.23.2 3.2
1) Designation: PH1-S2, e.g. P140-302) Weight including stiffeners (average values)3) „XXXX“ … project-specific designation
1) cut with 60° miter, weight: 15 [kg/m]2) Weight per single angle - angle connections consists of 4 angle plates
■ Numerical analysis of the static load-bearing capacity and bending test reports available upon request
■ Allowable tightening torques and mounting pre-load for set metrical set screws: see VDI guideline No. 2230
Wallplate beams
Datum
Ersatz durch:
Name
Blatt
Bearb:Gepr:
Ersatz für:
Format
Norm
Gruppe
DDlWDk
A41
DSI Austria, Alfred-Wagner-Straße 1, A-4061 Pasching/LinzPhone: +43-7229-61049-0 E-Mail: office@dywidag-systems.at
Gegenstand der Unterlage / Zeichnung ist unser geistiges Eigentum. Diese Zeichnung darf ohne unsere vorherige schriftliche Zustimmung weder vervielfältigt noch Dritten zu Kenntnis gebracht werden. Sie darf auch nicht in anderer Weise mißbräuchlich verwendet werden.(Urheberschutzgesetz v. 09.09.1965)
I:\50_CAD\1410\141020002002.idw
x
y
Gurtstab S2
Gurtstab S2
Aussteifungselement (Spinne)
30 -50
H
S1
H1
B
7
Please note: This brochure serves basic information purposes only. Technical data and information provided herein shall be considered non-binding and may be subject to change without notice. We do not assume any liabilityfor losses or damages attributed to the use of this technical data and any improper use of our products. Should you require further information on particular products, please do not hesitate to contact us.
"ALWAG" (AM 952/79), "AT" (AM 6138/2003), "AT-SYSTEM” (AM 6139/2003), "DYWI®" (4197869), "LSC" (AM 4326/2008), "OMEGA-BOLT®" (3258282), "POWER SET" (AM 6163/2002), and "TUBESPILE" (AM 4328/2008) are registered trademarks of DYWIDAG-Systems International GmbH."Combi Coat®" and "CT-BoltTM" are trademarks of Vik Ørsta AS. DYWIDAG-Systems International GmbH is a partner of Vik Ørsta AS.
0419
5-1/
08.1
2-w
eb h
e
EMEADYWIDAG-Systems International GmbHAlfred-Wagner-Strasse 14061 Pasching/Linz, AustriaPhone +43-7229-610 49 0Fax +43-7229-610 49 80E-mail alwag@dywidag-systems.atwww.alwag.com
North AmericaDSI Underground Systems Inc.9786 S Prosperity RoadWest Jordan, UT 84081, USAPhone +1-801-973 7169Fax +1-801-973 7172E-mail dsiunderground@dsiunderground.comwww.dsiunderground.com
South AmericaDSI Chile Industrial Ltda. Las Encinas #1387, Valle GrandeLampa, Santiago de Chile, ChilePhone +56-2-596 96 20Fax +56-2-596 96 69E-mail informaciones@dywidag-systems.clwww.dsi-chile.com
APAC/ASEANDYWIDAG-Systems International Pty. Ltd.25 Pacific HighwayBennetts Green, NSW 2290, AustraliaPhone +61-2-49 48 90 99Fax +61-2-49 48 99 56E-mail dsi@dywidag.com.auwww.dsiminingproducts.com/au
A u s t r i AA r g e n t i n AA u s t r A l i A
b e l g i u mb o s n i A A n d h e r z e g o v i n A
b r A z i lC A n A d A
C h i l eC o l o m b i A
C o s tA r i C AC r o At i A
C z e C h r e p u b l i Cd e n m A r k
e g y p te s t o n i AF i n l A n dF r A n C e
g e r m A n yg r e e C e
g u At e m A l Ah o n d u r A s
h o n g k o n gi n d o n e s i A
i tA lyJ A pA n
k o r e Al e b A n o n
l u x e m b o u r gm A l Ay s i A
m e x i C on e t h e r l A n d s
n o r w Ayo m A n
pA n A m ApA r A g u Ay
p e r up o l A n d
p o r t u g A lQ AtA r
s A u d i A r A b i As i n g A p o r e
s o u t h A F r i C As pA i n
s w e d e ns w i t z e r l A n d
tA i w A nt h A i l A n d
t u r k e yu n i t e d A r A b e m i r At e s
u n i t e d k i n g d o mu r u g u Ay
u s Av e n e z u e l A
Recommended