Tanjung Jati B Training
PA-FD-ID Fans
8/21/2019 PA-FD-ID Fans
2/53
Tanjung Jati B Training
Boiler Precipitator FGD Absorber
2 x 660MW (net)
P.T. Central Java PowerTanjung Jati B Units 1 & 2
8/21/2019 PA-FD-ID Fans
3/53
Tanjung Jati B Training
OPERATIONS
PA-FD-ID FANS
8/21/2019 PA-FD-ID Fans
4/53
Tanjung Jati B Training
PA-FD-ID FansLocation
PA FANS ID FANSFD FANS
8/21/2019 PA-FD-ID Fans
5/53
Tanjung Jati B Training
PA-FD-ID FansFunction
The fans serve to provide the following regarding
The operations of the Boiler, ESP & FGD Systems
FD FANS: Combustion Air for the Burners
ID FANS: Remove Flue Gas from the Boiler & ESP
and force the flue gas through the
FGD System to the Stack
PA FANS: Provide air for the operation of the
Pulverizers and transport of pulverized
coal to the Burners
8/21/2019 PA-FD-ID Fans
6/53
Tanjung Jati B Training
PA-FD-ID Fans
Forced Draft (FD)
Induced Draft (ID)
Primary Air (PA)
8/21/2019 PA-FD-ID Fans
7/53
FD Fans
Each FD Fan has a single inlet and provide
50% of the total airrequirement at Boiler
Maximum Continuous Rating firing Bengalon
Coal at 1% sulfur.
The FD Fans are theAxial type versus the
Centrifugal type PA and ID Fans.
Air flow through the fan is controlled by theVariable Pitch Blades.
Tanjung Jati B Training
8/21/2019 PA-FD-ID Fans
8/53
FD FansAxial Design
MOTOR
INLET BOX
AIR FLOW BLADES
DIFFUSER
LUBE AND/OR
HYDRAULIC UNIT
STRAIGHTENING
VANES
OUTLET AIR
Tanjung Jati B Training
8/21/2019 PA-FD-ID Fans
9/53
FD Fans
Secondary Air System
FD Fan
FD Fan
SCAH
SCAH
Air Heater
Air Heater
Air Foil B
Air Foil A
Burner Level
Windbox
(typical)
Inlet
Silencer
Screen
N
Tanjung Jati B Training
Hot Crossover
Duct
8/21/2019 PA-FD-ID Fans
10/53
Tanjung Jati B Training
ID FansFan Bearings
The ID Fans have sleeve-type bearings which
require continuous water flow for cooling.Water is supplied by the Closed Circuit Cooling
Water (CCCW) system.
The bearing are also equipped with a oil levelsite gauge. If the oil appears cloudy or frothy,
most likely cooling water has entered the oil
cavity and has contaminated.
8/21/2019 PA-FD-ID Fans
11/53
FD Fans
Some Components and Terms to remember
Variable Pitch Blades
Hydraulic-Lube Unit
Fan Stall
Tanjung Jati B Training
8/21/2019 PA-FD-ID Fans
12/53
Tanjung Jati B Training
FD FansVariable Pitch Blades
Variable Pitch Blades, internal to the Fan
Housing are used to control air flow through
the fan.
A stand alone Hydraulic Oil Unit provides thenecessary oil pressure to adjust the pitch of
the Blades.
8/21/2019 PA-FD-ID Fans
13/53
Tanjung Jati B Training
FD FansHydraulic Unit
The Hydraulic Unit serves two functions
Adjust the pitch of the Blades
Provide Lube Oil for the Fan Bearings
8/21/2019 PA-FD-ID Fans
14/53
Tanjung Jati B Training
FD FansHydraulic Unit
The Hydraulic Oil Unit consists of the following
Local Control Cabinet
Two (2) motor-driven oil pumps
Oil HeaterOil Cooler
Oil Sump
Filters
Instrumentation (Flow switch, Level switch)
8/21/2019 PA-FD-ID Fans
15/53
Tanjung Jati B Training
FD FansHydraulic Unit
The Control Cabinet has the following features
Indication Lamps
Oil Pump Status
Oil Heater StatusHigh/Low Oil Temperature
Low Oil Level
Low Oil Flow
Low Oil Pressure
8/21/2019 PA-FD-ID Fans
16/53
Tanjung Jati B Training
FD FansHydraulic Unit
The Control Cabinet has the following features
Buttons & Switches
Oil Pump Select
Oil Pump StartOil Pump Stop
Oil Pump Hand/Off/Auto (x2)
Alarm Reset
8/21/2019 PA-FD-ID Fans
17/53
Tanjung Jati B Training
FD FansHydraulic Unit
The Oil Pumps are interlocked such that a
significant drop in oil pressure from the
operating pump will start the stand-by
pump.
8/21/2019 PA-FD-ID Fans
18/53
Tanjung Jati B Training
FD FansHydraulic Unit
CONTROL PANEL
OIL SUMP
OIL PUMPS
8/21/2019 PA-FD-ID Fans
19/53
Tanjung Jati B Training
FD FansStart-Up
Prior to starting an FD Fan, the Hydraulic Unitmust be available and operating. If the Hydraulic
Unit panel indicates any alarms, these should be
investigated and cleared prior to starting the Fan.
An Induced Draft Fan must be in service prior to
starting an FD Fan.
8/21/2019 PA-FD-ID Fans
20/53
Tanjung Jati B Training
FD FansAutomatic Operation
During automatic operation the FD Fan Inlet
Vanes will control air pressure in the Secondary Hot
Crossover Duct to the desired set point.
8/21/2019 PA-FD-ID Fans
21/53
Tanjung Jati B Training
FD FansTrip Interlocks
Fans will trip under the following conditions
Secondary Air Duct Pressure High-High
High Fan Bearing Vibration
High Fan Bearing Oil Temperature
Furnace Pressure High-High
Loss of Flow Path
Loss of Breaker (power failure)High Motor Amps (time delay)
Hydraulic Oil Unit Failure
8/21/2019 PA-FD-ID Fans
22/53
Tanjung Jati B Training
FD FansShutdown
Prior to stopping the FD Fan, the fans loading
should be reduced manually and slowly. This
wil l allow the other operating FD Fan to maintaincontrol of the Secondary Air Duct pressure.
8/21/2019 PA-FD-ID Fans
23/53
Tanjung Jati B Training
FD FansStall
Fan stall is a condition where there is a
sudden and significant drop in the differential
pressure (air f low) between the fan inlet and outlet.
A differential pressure transmitter is provided to
monitor air flow condit ions.
8/21/2019 PA-FD-ID Fans
24/53
Tanjung Jati B Training
FD FansStall
Fan stall is a serious and potentially danger situation
which is usually accompanied by vibration and
increased noise. Fan blade failure can occur.
When fan stall is suspected, the fan should be
SHUT DOWN immediately.
8/21/2019 PA-FD-ID Fans
25/53
Tanjung Jati B Training
PA-FD-ID Fans
Forced Draft (FD)
Induced Draft (ID)
Primary Air (PA)
8/21/2019 PA-FD-ID Fans
26/53
Tanjung Jati B Training
ID Fans
Description
The Induced Draft (ID) Fans are single-speed,
double-inlet, centrifugal-type fans.
The ID Fans operate at a relatively low speed
compared to the FD Fans and Primary Air Fans.
8/21/2019 PA-FD-ID Fans
27/53
Tanjung Jati B Training
ID Fans
Function
The ID Fans remove flue gas from the Boiler and the
Precipitator and force those flue gasses through the
FGD System to the stack.
8/21/2019 PA-FD-ID Fans
28/53
Tanjung Jati B Training
PA-FD-ID FansLocation
PA FANS ID FANSFD FANS
8/21/2019 PA-FD-ID Fans
29/53
Tanjung Jati B Training
ID FansOperation
ID Fans, serve to control Furnace Draft Pressure
during Unit operation. During start-up of the Boiler,
the ID Fan Inlet vanes and Start-Up Damperwork in
unison to control the flow through the ID Fan.
8/21/2019 PA-FD-ID Fans
30/53
ID Fans
Flue Gas System
Tanjung Jati B Training
Man-Safe
Double Dampers
with Seal Air Tri-Sector
Air Heaters
Precipitators
Boiler
ID Fans
Start-Up
Control Damper
Guillotine Isolation
Damper with Seal Air
To FGD
8/21/2019 PA-FD-ID Fans
31/53
Tanjung Jati B Training
ID FansFan Bearings
The ID Fan have sleeve-type bearings which
require continuous water flow for cooling.Water is supplied by the Closed Circuit Cooling
Water (CCCW) system.
The bearing are also equipped with a oil levelsite gauge. If the oil appears cloudy or frothy,
most likely cooling water has entered the oil
cavity and has contaminated.
8/21/2019 PA-FD-ID Fans
32/53
Tanjung Jati B Training
ID FansStart-Up
Prior to starting an ID Fan, an operator should
check the oil level in the bearing and be sure
that the CCCW isolation valves are open.
Be sure all housing doors are closed and anoperator should be present when the fan is started.
8/21/2019 PA-FD-ID Fans
33/53
Tanjung Jati B Training
ID FansStart-Up
When the ID Fan is commanded to start, the
fans Outlet Isolation Guillotine Damperwillclose. Once the dampers close limit switch
is activated the fan will start. The isolation
damper will open after a time delay.
After the ID Fan is started, the operator will
manually modulate both the FD & ID Fans to
achieve the desired air f low and furnace
pressure prior to putting control in automatic.
8/21/2019 PA-FD-ID Fans
34/53
Tanjung Jati B Training
ID FansAutomatic Operation
The ID Fans inlet vanes modulate to controlFurnace Pressure only.
If two fans are running and one trips, the
remaining ID fan will control Furnace Draftwhile the unit runs back or reduces load
towards 50%.
8/21/2019 PA-FD-ID Fans
35/53
Tanjung Jati B Training
ID FansAutomatic Operation
How does an operator know both fans areoperating at the same load?...
The motor running amps wil l be the same!
8/21/2019 PA-FD-ID Fans
36/53
Tanjung Jati B Training
ID FansTrip Interlocks
Fans will trip under the following conditions
High Fan Bearing Vibration
High Fan Bearing Oil Temperature
Furnace Pressure High-HighLoss of Flow Path
Loss of Breaker (power failure)
High Motor Amps (time delay)
8/21/2019 PA-FD-ID Fans
37/53
Tanjung Jati B Training
ID FansShutdown
Similar to the FD Fan, the inlet vane controls
should be put into manual and the Inlet Vanes
should be closed slowly. When the fan is at
minimum loading, the fan can be stopped.
8/21/2019 PA-FD-ID Fans
38/53
Tanjung Jati B Training
PA-FD-ID Fans
Forced Draft (FD)
Induced Draft (ID)
Primary Air (PA)
8/21/2019 PA-FD-ID Fans
39/53
Tanjung Jati B Training
PA-FD-ID Fans
Location
PA FANS ID FANSFD FANS
8/21/2019 PA-FD-ID Fans
40/53
Primary Air (PA) FansFunction
Two (2) 60% capacity, single-speed,
centrifugal-type primary air fans are neededfor the following
Circulation of coal in the pulverizers
Hot air to dry the coal
Transport pulverized coal to the burners
Primary air accounts for approximately 25%
of the air flow required for combustions
Tanjung Jati B Training
8/21/2019 PA-FD-ID Fans
41/53
Primary Air
Tanjung Jati B Training
MILL A
MILL B
MILL C
MILL D
MILL E
MILL F
PA Fans
Inlet Screen
and Silencer
Isolation
Dampers
Cold Air Duct
Hot Air
Duct
Tri-Sector
Air Heater
Control DampersGuillotine
Isolation Damper
To Seal
Air Fans
Air Measurement
8/21/2019 PA-FD-ID Fans
42/53
Tanjung Jati B Training
PA Fans
Fan Bearings
The PA Fans have sleeve-type bearings which
require continuous water flow for cooling.
Water is supplied by the Closed Circuit Cooling
Water (CCCW) system.
The bearing are also equipped with a oil levelsite gauge. If the oil appears cloudy or frothy,
most likely cooling water has entered the oil
cavity and has contaminated.
8/21/2019 PA-FD-ID Fans
43/53
Tanjung Jati B Training
PA Fans
Fan Motors
The PA Fan Motors have oil-lubricated bearings
which requires a stand alone lube oil skid. One
lube oil skid supplies oil to both motors.
8/21/2019 PA-FD-ID Fans
44/53
Tanjung Jati B Training
PA Fans
Fan Motor Lube Oil Skid
The lube skid has very similar components
to the FD Fan oil skid
Two (2) Oil Pumps
Oil Sump
Filters
Air Cooler
Oil Pressure & Temperature Switches
GaugesJunction Box
PA F
8/21/2019 PA-FD-ID Fans
45/53
Tanjung Jati B Training
PA Fans
Start-Up
Prior to starting an PA Fan, an operator should
check the oil level in the bearing and be surethat the CCCW isolation valves are open.
Be sure all housing doors are closed and an
operator should be present when the fan is started.
PA F
8/21/2019 PA-FD-ID Fans
46/53
Tanjung Jati B Training
PA Fans
Start-Up
Prior to starting an PA Fan, an operator should
also check to be sure that the Motor Lube OilSkid is started and functioning properly (no alarms).
PA F
8/21/2019 PA-FD-ID Fans
47/53
Tanjung Jati B Training
PA Fans
Start-Up
Prior to starting a pulverizer, a PA must be started
first. When the fan is commanded to start, the fansOutlet Isolations Damper will be commanded to close.
once the Dampers closed limit switch is activated,
the PA Fan starts. After a specified time delay, the
Outlet Isolation Damper opens.
PA F
8/21/2019 PA-FD-ID Fans
48/53
Tanjung Jati B Training
PA Fans
Automatic Operation
The loading of the PA Fans is controlled by variableInlet Vanes. This is determined by the Primary Air
Hot Crossover Duct Pressure Set Point.
If two fans are in service and one trips, the Boiler
load will runback to approximately 60% load.
PA F
8/21/2019 PA-FD-ID Fans
49/53
Tanjung Jati B Training
PA Fans
Trip Interlocks
Fans will trip under the following conditions
Boiler MFT (pulverizers tripped)
High Fan Bearing Vibration
High Fan Bearing Oil TemperatureLoss of Flow Path
Loss of Breaker (power failure)
High Motor Amps (time delay)
PA F
8/21/2019 PA-FD-ID Fans
50/53
PA FansShutdown
Tanjung Jati B Training
Similar to the other fans, the inlet vane controlsshould be put into manual and the Inlet Vanes
should be closed slowly. When the fan is at
minimum loading, the fan can be stopped.
PA F
8/21/2019 PA-FD-ID Fans
51/53
PA FansShutdown
Tanjung Jati B Training
Once the last pulverizer has been shutdown,the Primary Air Fans can be stopped.
PA FD ID Fans
8/21/2019 PA-FD-ID Fans
52/53
PA-FD-ID Fans
General Start-Up Sequence
Tanjung Jati B Training
The start-up sequence for the fans is as follows.This assumes all fans are available
ID Fan A or ID Fan B
FD Fan A FD Fan B
ID Fan B ID Fan A
FD Fan B FD Fan A
PA Fans A/B (prior to starting a pulverizer)
8/21/2019 PA-FD-ID Fans
53/53
Tanjung Jati B Training
OPERATIONS
PA-FD-ID FANS
(END)