Operating Instructions for FS 345 with FS 101 and CS 300 FS GB
FS 345 Door Controls / Rev.A 0.0 – 1
2 – FS 345 Door Controls / Rev. A 0.0
1. Contents
1. Contents 22. Information in this document 23. General safety instructions 34. Overview of products 45. Commissioning 56. Limit switches 167. Programming with the LCD monitor 188. Navigator (LCD monitor only) 209. Overview of functions 2210. Rechargeable battery and battery charger 3011. Motor brake and auxiliary motor 3412. Technical data 3613. Maintenance 3614. EC Declaration of Incorporation 37
Original operating instructions − Protectedbycopyright.− Nopartoftheseinstructionsmaybereproducedwithout
our prior approval. − Subjecttoalterationsintheinterestoftechnicalprogress.− Alldimensionsaregiveninmillimetres.− Theillustrationsarenottruetoscale.
Meaning of symbols
DANGER!
Safetynoticeindicatingadangerthatwilldirectlyresultindeathorsevereinjury.
WARNING!
Safetynoticeindicatingadangerthatcouldresultindeathorsevereinjury.
CAUTION!
Safetynoticeindicatingadangerthatcanresultinslightormoderateinjuries.
NOTICE
Safetynoticeindicatingadangerthatcanresultindamageto property or in irreparable damage to the product.
CHECK
Reference to a check that needs to be carried out.
REFERENCE
Reference to separate documents that must be observed.
� Instruction requiring action
− List,itemisation
� Reference to other sections of this document
2. Information in this document
GB
FS 345 Door Controls / Rev.A 0.0 – 3
3. General safety instructions
DANGER!
Failure to comply with the documentation could result in life-threatening danger!
� Be sure to follow all the safety instructions in this docu-ment.
WarrantyThe function and safety of the equipment is only guaranteed if the warning and safety instructions included in these operat-ing instructions are adhered to.MFZAntriebeGmbH+Co.KGisnotliableforpersonalinjuryor damage to property if these occur as a result of the warn-ings and safety advice being disregarded.MFZ does not accept any liability or warranty for damage due to the use of non-approved spare parts and accessories.
Intended useTheFS345controlisintendedexclusivelyforcontrollingdoorsystems with mechanical limit switches.
Target groupOnlyqualifiedandtrainedelectriciansmayconnect,pro-gramme and service the control.Qualifiedandtrainedelectriciansmustmeetthefollowingrequirements:− Knowledgeofthegeneralandspecificsafetyandaccident
preventionregulations,− Knowledgeoftherelevantelectricalregulations,− Trainingintheuseandcareofappropriatesafetyequip-
ment,− Capableofrecognisingthedangersassociatedwithelec-
tricity.
Instructions regarding installation and connection− ThecontrolisdesignedwithXtypeterminals.− Thecontrolmustbedisconnectedfromtheelectricity
supply before carrying out any electrical work. It must be ensured that the electricity supply remains disconnected for the duration of the work.
− Localprotectiveregulationsmustbecompliedwith.
Information concerning operation− Unauthorisedpersons(particularlychildren)shouldnotbe
allowedtoplaywithpermanentlyinstalledadjustingorcontrol devices.
− Keepremotecontrolbeyondthereachofchildren.
Regulations and bases for testingForconnecting,programmingandservicing,thefollowingregulations must be observed (the list is not exhaustive).
Construction product standards− EN13241-1(Productswithoutfireresistanceorsmoke
control characteristics)− EN12445(Safetyinuseofpoweroperateddoors-Test
methods)− EN12453(Safetyinuseofpoweroperateddoors-Re-
quirements)− EN12978(Safetydevicesforpoweroperateddoorsand
gates - Requirements and test methods)
EMC− EN55014-1(Electromagneticcompatibility-Requirements
for household appliances)− EN61000-3-2(Disturbancesinsupplysystems-harmonic
currents)− EN61000-3-3(Disturbancesinsupplysystems-voltage
fluctuations)− DINEN61000-6-2(Electromagneticcompatibility(EMC)
- Part 6-2: Generic standards – Immunity for industrial environments)
− DINEN61000-6-3(Electromagneticcompatibility(EMC)- Part 6-3: Generic standards – Emission standard for residential,commercialandlight-industrialenvironments)
Machinery Directive− EN60204-1(Safetyofmachinery,electricalequipmentof
machines Part 1: General requirements)− ENISO12100(Safetyofmachinery–generalprinciplesfor
design - risk assessment and risk reduction)
4 – FS 345 Door Controls / Rev. A 0.0
Low voltage− DINEN60335-1(Householdandsimilarelectricalappli-
ances-Safety-Part1:Part1:Generalrequirements)− DINEN60335-2-103(Householdandsimilarelectrical
appliances-Safety-Part2-103:Particularrequirementsfordrivesforgates,doorsandwindows)
CommitteeforWorkplaces(ASTA)− ASRA1.7(Workplaceregulation“Doorsandgates“)
General safety instructions− Toenablefault-freeoperationtobeguaranteed,itis
imperative that the rechargeable battery be replaced after every two years of operation. If this maintenance instruc-tionisdisregarded,thefunctionalsafetyofthesystemandthus also the safety of buildings and persons cannot be guaranteed.
− Toensurethatthesystemalwaysfunctionsconsistently,thefirealarmfunctionmustbecheckedonceeveryfourweeks.In order to check at the same time that the rechargeable batteryalsofunctionscorrectly,thecontrolmustbediscon-nectedfromthemains.Inthisway,theemergencyfunctioncan be checked to ensure that the door is closed automati-cally by the auxiliary motor.
− Emergencyoperationisnotpossibleifthereisafaultinthesafety circuit of the door operator.
− Toavoidadeepdischargeoftherechargeablebattery,thebatteryshouldnotbeconnectedtotheFS101unituntilthesystemisputintooperationforthefirsttime.Ifdeepdischargeoccurs,thebatterycannotberechargedagainand must be replaced immediately.
4. Overview of products
4.1 Product descriptionTheFS345controlcanbeusedinconnectionwithFDF,FT,FTAandFDSfire-protectiondrivesaswellaswithhydraulicdrives.InversionFS345HY,hydraulicdrivesareused.
TheFS345controlconsistofaCS300FSdoorcontrolunit,anFS101auxiliarycircuitboardandarechargeablebatteryforemergencypowersupply,magneticcouplings,DC-operat-edmotors,24Vmotorbrakes.
Incaseoffireorpowercuts,theemergencyrechargeablebattery provides the energy required for the auxiliary motor to close the door or for the motor brake to hold the door in position.
Thefiremodeistriggeredbyacontinuouscommandinthefirealarmcontactoristimeactivatedifthemainspowersup-plyfails.Inthecaseoffire,thedoorcloseswiththeclosingedgesystemdeactivated,or,optionally,withtheclosingedgeactivated.
4.2 Various optionsThefollowingmodelsofFS345controlcanbesupplied:− FS345controlfordeadmanoperation− FS345controlforautomaticoperation− FS345controlforautomaticoperationwiththeclosing
edgesystemactivatedinthecaseoffire
The following housing models are available:− HousingwithOPEN-STOP-CLOSEbuttons− HousingwithON/OFFkeyswitch− Housingwithmainswitch− HousingwithemergencyOFFswitch
The operating instructions describe the connection options andmodelsoftheFS345control.
General safety instructions
GB
FS 345 Door Controls / Rev.A 0.0 – 5
4.3 Product drawing of CS 300 FS with FS 101
K06
K04 K05 K06 K07 K08 K09
K10
K11
K12
CS300FScircuit board
FS101circuit board
Battery
5. Commissioning
5.1 General information
Toguaranteethattheequipmentfunctionsproperly,itmustbe ensured that:− Thedoorisinstalledandoperational.− TheMFZoperatormotorisinstalledandreadyforopera-
tion.− Thecommandandsafetydevicesareinstalledandreadyfor
operation. − ThecontrolhousingwiththeFS345controlisinstalled.
REFERENCE
The relevant manufacturers’ instructions must be adhered to fortheinstallationofthedoor,theMFZoperatormotor,andthe command and safety devices.
5.2 Mains connection
PreconditionsToguaranteethatthecontrolfunctionproperly,thefollowingpoints must be ensured:- The mains voltage must correspond to the voltage stated on
the type plate.- The mains voltage must be the same as the voltage of the
operator.-Forathree-phasecurrent,aclockwiserotatingfieldis
required.-Forapermanentconnection,anall-polemainswitchmust
be used.-Forathree-phaseconnection,only3-wayautomaticcircuitbreakers(10A)maybeused.
NOTICE
Malfunctions can occur as a result of incorrect installation of the control!Beforeswitchingonthecontrolforthefirsttime,acheckmust be carried out after completing the wiring to ensure that all the motor connections at the motor and at the con-trolissecurelyfixed.Allcontrolvoltageinputsaregalvani-cally isolated from the supply.
6 – FS 345 Door Controls / Rev. A 0.0
5.3 Initial operation FS 101 emergency op-eration circuit board
GeneralTheFS101circuitboardincludesachargerfortherecharge-able battery and a microprocessor for controlling the auxiliary drive or the motor brake.ThecircuitboardisconnectedtotheCS300FSdoorcontrolunit in the factory and if it is purchased together with a door operator,thecorrectsettingsforthatoperatorarealsopresetin the factory.Allthatremainstobeconnectedisafirealarm,andtherechargeablebatterymustbeconnectedtotheFS101circuitboard via a plug.
NOTICE
Malfunctions due to incorrect installation of the battery!Topreventdeepdischargeoftherechargeablebattery,thebatteryshouldnotbeconnectedtotheFS101circuitboarduntilthedoorisputintooperation.Topreventerrors,thebatterymustbeconnectedtotheFS101circuitboardbefore the connection is made to the mains power supply.
5.4 Circuit diagram for mains connection and motor
CS 300 FS
L1 L2 L3 N
PE
PE
PE~
-
X1
T1
K2K1
U V W B1 B2X2
M1
400V / 50H
z / 3 / N / PE
1 3 5
2 4 6
1 3 5
2 4 6
M
L1N X12
Key: K1: CLOSEcontactorK2: OPENcontactorM1: MotorT1: TransformerX1: TerminalblockformainsconnectionX2: Terminalblockformotor
Connection:− Connectthecontroltothemainspowersupply.− Connectthecontroltothemotor.− Cablegroupsmustbesecuredclosetotheirrelevanttermi-
nals using a cable tie.
Initial operation
- +
Battery
FS101circuit board
Battery
GB
FS 345 Door Controls / Rev.A 0.0 – 7
FS 101 - CS 300 FS (ready-wired)
FS101-P1-1
8 – FS 345 Door Controls / Rev. A 0.0
5.5 Mains power connection and motor 230 V AC version
CS 300 / FS 230 V AC, 3~
L1 L2 L3 N
PE
PE
PE~
-
X1
T1
K2K1
U V W B1 B2X2
M1
230V / 50H
z / 3 / PE
1 3 5
2 4 6
1 3 5
2 4 6
M
L1N X12
Key: K1: CLOSEcontactorK2: OPENcontactorM1: MotorT1: 230VtransformerX1: TerminalblockformainsconnectionX2: Terminalblockformotor
Connection:− Connectthecontroltothemainspowersupply.− Connectthecontroltothemotor.− Cablegroupsmustbesecuredclosetotheirrelevanttermi-
nals using a cable tie.
CS 300 / FS 230 V AC, 1~
L1 N
PE
PE
PE~
-
X1
T1
K2K1
AUF ZU N B1 B2X2
M1
230V / 50H
z / 1~ / PE
1 3 5
2 4 6
1 3 5
2 4 6
M
L1N X12
Key: K1: CLOSEcontactorK2: OPENcontactorM1: MotorT1: 230VtransformerX1: TerminalblockformainsconnectionX2: Terminalblockformotor
Connection:− Connectthecontroltothemainspowersupply.− Connectthecontroltothemotor.− Cablegroupsmustbesecuredclosetotheirrelevanttermi-
nals using a cable tie.
Initial operation
GB
FS 345 Door Controls / Rev.A 0.0 – 9
5.6 Connection of command and safety devices for normal door operation X3/CS 300 FS
Command and safety devices can be connected via terminals X3andX4.
X3 / CS 300 FS
X6 / CS 300 FS
X7 / CS 300 FS
-DOWNSWITCH
- Impulse button
-UPSWITCH
-STOPbutton
-Emergencyoff,slackropeswitch,wicketdoorcontact,drawinprotection
-SocketsforinternalON-OFFswitch-Socketsforinternal3-buttoninputunit
STOP
OPEN
CLOSE
10 – FS 345 Door Controls / Rev. A 0.0
5.7 Connection examples for command and safety devices (terminal block X3/CS 300 FS)
OPEN / STOP / CLOSE buttons (6-lead solution)
1 2 3 4 5 6 7 8 9 10
OPEN / STOP / CLOSE buttons (4-lead solution)
1 2 3 4 5 6 7 8 9 10
ButtonSTOP
ButtonOPEN
ButtonCLOSE
ButtonSTOP
ButtonOPEN
ButtonCLOSE
UP / DOWN key switch
1 2 3 4 5 6 7 8 9 10
Impulse button key switch (sequence control)
1 2 3 4 5 6 7 8 9 10
ButtonOPEN
ButtonCLOSE
ButtonIMPULSE
Initial operation
GB
FS 345 Door Controls / Rev.A 0.0 – 11
5.8 Connection examples for safety devices X4/CS 300 FS
Terminal block X48.2 kOhm closing edge safety device
Terminal block X4Optoelectronic closing edge safety system
+-
9
10
1
2
3
4
5
6
7
8wt
gr
br
GndSignal
+12V DC
24VDCforexternalswitching devices
Photoelectric drive-through barrier*
8.2 kOhm closing edge safety device*
HALFOPENlimitswitch
24VDCforexternalswitching devices
Photoelectric drive-through barrier*
HALFOPENlimitswitch
Opto closing edge safety device*
Terminal block X4Pneumatic safety edge protection - pressure sensor test
8k2
Terminal block X4MFZ-type leading photoelectric barrier
+-
9
10
1
2
3
4
5
6
7
8wt
grbr
GndSignal
+12V DC
1
2
3
4
5
6
7
8
8k2
A 24VDCforexternalswitchingdevicesB Drive-through photoelectric barrier*C Leading photoelectric barrierD HALFOPENlimitswitch
Adjustmentofthepre-limitswitchCLOSEfortheleadingphotoelectric barrier− OntheCS300FS,setthemodeforrelay1to11(pre-limit
switchCLOSE)− Drivethedoorinthe“close”directionuntiltheleading
photocelljusttouchestheground.− Intheinputmenu,setthepre-limitswitchCLOSEtothis
position
* effective in down direction only
24VDCforexternalswitching devices
Photoelectric drive-through barrier*
HALFOPENlimitswitch
Closing edge safety device
DW-Test*
A
B
C
D
X5 / CS 300 FSX4 / CS 300 FS
Relay 1MOD 11
12 – FS 345 Door Controls / Rev. A 0.0
5.9 Product drawing of FS 101 circuit board + rechargeable battery
K04 K05 K06 K07 K08 K09
K10
K11
K12
FS101-P1-1
X01
X02
X03
X04
X05
X10
X06X07
X08
X09
+ - AKKU
TEST
RES
ETTIME2
TIME1
S303
F200
ON
Battery
FS 101 circuit board
Key to FS 101 circuit board
X01/X02 Powersupply230V/PEX03 LimitswitchconnectionX04 Outputsfortheauxiliarymotor,brake, auxiliary relayX05 ActivationoftheCS300FScircuitboardX06 FirealarmconnectionX07 Potential-freeoutputforfaultindicatorX08 Potential-freeoutputforfirealarmX09 Potential-freeoutputforclosingedgesafety deviceX10 Input,external24V+-BATT Terminalblockforbatterypack
Time 1 Time-controlled closing if mains power supply failsTime 2 Timing element for door seal functionS303 DIPswitchReset Button – switch off buzzerTest Button for testing emergency operationF200 3.15AfuseforbatterychargerON Button
K04 AuxiliarymotorrelayK05 MotorbrakerelayK06 OPEN/CLOSEcommandrelayK07 UpperswitchrelayK07 LowerswitchrelayK09 StoprelayK10 Operation/errorrelayK11 EmergencyclosingrelayK12 Closingedgesafetydevice(SKS)relay
Initial operation
GB
FS 345 Door Controls / Rev.A 0.0 – 13
5.10 DIP switches:
1ON DooroperatortypesFT(+HY)*1OFF DooroperatortypesFDF+FTA2 ON Fire alarm as normally open contact2 OFF Fire alarm as normally closed contact3ON Emergencyclosingwith400VAC/24VDC3OFF Emergencyclosingwith24VDC4ON WithCESD(SKS)inemergencyoperation4OFF WithoutCESD(SKS)inemergencyoperation5 ON Door closes if an error occurs5 OFF Door remains open if an error occurs6ON (OperatortypeHY)*6 OFF Operator type FT
WhenmakingchangestotheDIPswitchsettings,thefollow-ing procedure must be observed:1. Switchoffthemainsvoltage2. Switchofftherechargeablebatteryvoltage3. Change the DIP switch positions as required4. Switchontherechargeablebatteryvoltage5. Switchonthemainsvoltage
*versionHYonly
5.11 Types of door operator
TheFS345controlisdesignedforusewithtwodifferenttypes of door operator.
FT operatorsDIP 1 ON and DIP 6 OFF1.FTdooroperatorswith24VDCmotorbraking.Inemergencymode,thedoorisclosedviathe24VDCauxiliarymotor.The weight of the door is held by the ener-gised motor brake.The power supply comes from the mains adapterontheFS101circuitboard;ifthemainspowerisinterrupted,powerissuppliedfrom the rechargeable battery.(DIP6ONrequiredforversionHY)
FD (FDF, FTA, FDS) operatorsDIP 1 OFF1.FD(FDF,FTAandFDS)dooroperatorswitha24VDCauxiliarymotorand24VDCmotorbrake(FDF5).Inemergencymode,thedoorisclosedviathe24VDCauxiliarymotor.The power supply comes from the mains adapterontheFS101circuitboard;ifthemainspowerisinterrupted,powerissuppliedfrom the rechargeable battery.
14 – FS 345 Door Controls / Rev. A 0.0
5.12 FS 101 connections
2
1
2
1
2
1
2
1
2
1
X09
X08
X07
X06
X10
X051 2 3 4 5 6X03
X04
M
+-
* refer to the appendix for connection details for operators FT 3 and FDF 60
CESD(SKS)Potential-free relay
EMERGENCYOPERATIONPotential-free relay
OPERATION/ERRORPotential-free relay
INPUTFIREALARM
24VDC/50mA
Potential-free relayOPEN/CLOSEcommand
MotorbrakeforFT/FDFoperators*
Auxiliarymotor*
Initial operation
GB
FS 345 Door Controls / Rev.A 0.0 – 15
5.13 Connection example for fire alarm con-tact
Terminal strip X06 (potential-free continuous contact as normally closed contact)
2
1
X06/FS101 Dip 2 = OFF
1
2
3
4
ON OFF
5
6
2
X10/FS101+-
1
Terminal strip X06 (potential-free continuous contact as normally open contact)
Dip 2 = ON
1
2
3
4
ON OFF
5
62
1
X06/FS101
2
X10/FS101+-
1
5.14 Messages
Terminal strip X07K10operation/errorrelay
X07/FS101
Innormaloperationcontactclosed,opensintheeventofanerror.Rechargeablebatteryfault/mainspowerfailure:switchesifthe battery is defective or if the battery voltage is less than 19V.
Fire alarm contact
Supplyvoltage24VDC,max.50mA
Fire alarm contact
Supplyvoltage24VDC,max.50mA
Terminal strip X08K11emergencyclosingrelay
X08/FS101
Potential-free switching contact for emergency operation is active.Switchesintheeventofemergencyclosing(contactclosed).
Terminal block X4K06operatorcommandrelay
X04/FS101
Potential-freeswitchingcontactforCLOSEorOPENcommanddepending on DIP switches 1 and 3. (See12and13.1forwiringandfunction)
Terminal strip X09K12closingedgesafetyedge(SKS)relay
X09/FS101
Potential-freeswitchingcontact,displaysstatusofCESD(SKS)
16 – FS 345 Door Controls / Rev. A 0.0
6. Limit switches
6.1 Limit switches
Connectionarrangementforlimitswitches(CS300terminalsX11,X10andFS101terminalsX03,X05)
1
2
3
4
5
6
7
8
X03/FS101**
1
2
3
4
5
6
7
8
9
10
8
7
6
5
4
3
2
1
6
5
4
3
2
1
5 6 7 8
X05/FS101*
X11/CS300 FS
X10/CS300 FS*
1
2
3
1 Limit switch OPEN2LimitswitchCLOSE3Pre-limitswitchCLOSE5Thermalprotection,motor*6 Emergency operation (normally closed contact)**7SafetylimitswitchCLOSE8SafetylimitswitchOPEN
* ready wired** ready wired if supplied with operator
The limit switches (with the exception of the pre-limit switch) areanalysedbytheFS101circuitboard,andthevaluesarepassedontotheCS300FScircuitboard.
� TheassignmentofterminalX11(limitswitch)isdifferentfromtheassignmentgiventoterminalsintheAS130.Thismustbetakenintoaccountintheeventofretrofits
Safetycircuit
-+CLOSEOPEN
GB
FS 345 Door Controls / Rev.A 0.0 – 17
6.2 FDF / FTA / FDS limit switch settings
1. AdditionalOPENlimitswitch green2. Limit switch OPEN green3. SafetylimitswitchOPEN red4. SafetylimitswitchCLOSED red5. LimitswitchCLOSED white6. AdditionallimitswitchCLOSED white
NOTICE
Damage to property or irreparable damage due to incorrect adjustment!The door can be damaged if it is driven beyond the end positionwhileadjustmentsarebeingmade.
1. SelecttheADJUSTMENTmenuonthedisplay2. MovethedoortothedesiredCLOSEDpositionwiththe+
and - buttons.3. Setcontrolcam5(white)sothatthelimitswitchisactu-
ated.4. TightenfasteningscrewA.5. ScrewBcanbeusedtocarryoutfinetuning.6. MovethedoortothedesiredOPENpositionwiththe+
and - buttons.7. Setcontrolcam2(green)sothatthelimitswitchisactu-
ated.8. TightenfasteningscrewA.9. Safetylimitswitches3and5(red)mustbesetsothat
they are triggered as soon as the control limit switches are crossed.
10. Afterthetrialrun,checkthetightnessofthefasteningscrews.
11. Auxiliarylimitswitches1and6haveapotential-freechangeover contact
18 – FS 345 Door Controls / Rev. A 0.0
7.1 Overview of the LCD monitor
AUTOMATIC O
STANDBY
A
B
C D E
F
G
H
Key:A: Modeofoperation/DIAGNOSISinfoB: Parameters/DIAGNOSISinfoC Button(+)D: Button (-)E Button (P)F Value/statusG Value/statusH Jumper
7.2 LCD monitor, modes of operation
The control has four modes of operation with the LCD moni-tor:1.AUTOMATIC2.ADJUSTMENT3.INPUT4.DIAGNOSIS
IfjumperHisremoved,the(+)button,the(-)buttonandthe(P) button have no function. The display still functions.
Afterswitchingthecontrolon,itisinINITIALISATIONmode.ThedisplayshowsINITPHASEandthecontrolisnotyetreadyfor use. This phase lasts approx. 5 seconds.
7. Programming with the LCD monitor
6.3 FT limit switch settings
2. Limit switch OPEN green3. SafetylimitswitchOPEN red4. SafetylimitswitchCLOSED red5. LimitswitchCLOSED white6. AuxiliarylimitswitchCLOSED white
NOTICE
Damage to property or irreparable damage due to incorrect adjustment!The door can be damaged if it is driven beyond the end positionwhileadjustmentsarebeingmade.
1. SelecttheADJUSTMENTmenuonthedisplay2. MovethedoortothedesiredCLOSEDpositionwiththe+
and - buttons.3. Setcontrolcam5(white)sothatthelimitswitchisactu-
ated.4. TightenfasteningscrewA.5. ScrewBcanbeusedtocarryoutfinetuning.6. MovethedoortothedesiredOPENpositionwiththe+
and - buttons.7. Setcontrolcam2(green)sothatthelimitswitchisactu-
ated.8. TightenfasteningscrewA.9. Safetylimitswitches3and4(red)mustbesetsothat
they are triggered as soon as the control limit switches are crossed.
10. Afterthetrialrun,checkthatthefasteningscrewsarecor-rectly tightened.
11. Auxiliarylimitswitches1and6haveapotential-freechangeover contact
Limit switches
GB
FS 345 Door Controls / Rev.A 0.0 – 19
ADJUSTMENT,INPUTandDIAGNOSISmodesareexitedau-tomatically20secondsafterthelastbuttonwaspressed,andthecontrolthengoesintoAUTOMATICmode.
Operating mode 1: AUTOMATICThedoorsystemisoperatedinAUTOMATICoperatingmode.
Display:− Displaystheactionbeingcarriedout− Displaysanyerrors
Ifthe“PRESS/REL"parameterissettoMOD2orMOD3intheinputmenu,thedisplaychangesfromAUTOMATICtoMANUAL.
Operating mode 2: ADJUSTMENTInADJUSTMENTmode,theOPEN/CLOSEDendpositionsareset.
NOTICE
Malfunctions can occur as a result of incorrect operation of the control! InADJUSTMENTmode,thedoorwillnotstopautomaticallywhen it reaches the travel limit position if electronic end positions(AWG)areused. The door can be damaged if driven beyond the end posi-tion.
FineadjustmentscanbemadeintheINPUToperatingmode.
Display:− Displaysthetravellimitvalue
Operating mode 3: INPUTIntheINPUToperatingmode,thevaluesofvariousparam-eters can be altered.
Display:− Displaystheselectedparameter− Displaysthecurrentvalueorstatus
Operating mode 4: DIAGNOSISIntheDIAGNOSISoperatingmode,door-specificcheckscanbe queried.
Display:− Displaysthemonitoredfunction− Displaysthestatusofthefunction
20 – FS 345 Door Controls / Rev. A 0.0
8. Navigator (LCD monitor only)
AUTOMATIC
STANDBY
P
> 1
sec
ond
ADJUSTMENT
STANDBY
+->Position,DOOROPEN
ADJUSTMENT
MAINUP
Dead
man
ope
ratio
n
Setthemechanicallimit
switc
hes
as d
escr
ibed
in s
ec-
tion
22.
-->PositionDOORCLOSED
ADJUSTMENT
MAINDOWN
P
> 1
sec
ond
INPUT
+ a
nd
- >
2 s
ec.
INPUT
ENGLISH
:Scrollupthroughmenu:
+ >
2 s
ec.
Scrolldownthroughmenu:
- >
2 s
ec.
Selectvalue:
P >
1 s
ec.
Incr
ease
val
ue:
+
Decr
ease
val
ue:
-
Savevalue:
P
Retu
rn to
INPUTmode:
+ a
nd
- >
1 s
ec
INPUT
RUNTIME
:60
P >
1 s
econd
INPUT
OPE
N T
IME
: 0
INPUT
PREW
ARNING
:0
INPUT
REVERS.TIME
:3
INPUT
MOD1-3STANDBY
:MOD1
INPUT
QUICKCLOSE
:
OFF
INPUT
RELAY1
:MOD6
INPUT
RELAY2
:MOD7
INPUT
RELAY3
:MOD1
INPUT
RELAY4
:MOD19
INPUT
DW-TEST
:OFF
INPUT
DELAYUP
:OFF
INPUT
PRESS/REL
:MOD1
INPUT
SU/WI
:MOD1
INPUT
REVERS.
:MOD1
DIAGNOSIS
Scrollupthroughmenu:
+ >
2 s
ec.
Scrolldownthroughmenu:
- >
2 s
ec.
ReturntoAUTOMATICmode:
P
Onl
y qu
erie
s ar
e po
ssib
le.
UPPERSW
ITCH
:ON
LOWERSWITCH
:OFF
UPSWITCH
:OFF
PARTUP
:OFF
DOWNSWITCH
:OFF
SKS
:OFF
IMP.INPUT
:OFF
SWITCHCLOCK
:OFF
LIGHTBARR.
:ON
STOPCIRCUIT
:ON
S-POINT1
:ON
S-POINT2
:ON
CYCLE
:XXXX
GB
FS 345 Door Controls / Rev.A 0.0 – 21
AUTOMATIC
STANDBY
P
> 1
sec
ond
ADJUSTMENT
STANDBY
+->Position,DOOROPEN
ADJUSTMENT
MAINUP
Dead
man
ope
ratio
n
Setthemechanicallimit
switc
hes
as d
escr
ibed
in s
ec-
tion
22.
-->PositionDOORCLOSED
ADJUSTMENT
MAINDOWN
P
> 1
sec
ond
INPUT
+ a
nd
- >
2 s
ec.
INPUT
ENGLISH
:Scrollupthroughmenu:
+ >
2 s
ec.
Scrolldownthroughmenu:
- >
2 s
ec.
Selectvalue:
P >
1 s
ec.
Incr
ease
val
ue:
+
Decr
ease
val
ue:
-
Savevalue:
P
Retu
rn to
INPUTmode:
+ a
nd
- >
1 s
ec
INPUT
RUNTIME
:60
P >
1 s
econd
INPUT
OPE
N T
IME
: 0
INPUT
PREW
ARNING
:0
INPUT
REVERS.TIME
:3
INPUT
MOD1-3STANDBY
:MOD1
INPUT
QUICKCLOSE
:
OFF
INPUT
RELAY1
:MOD6
INPUT
RELAY2
:MOD7
INPUT
RELAY3
:MOD1
INPUT
RELAY4
:MOD19
INPUT
DW-TEST
:OFF
INPUT
DELAYUP
:OFF
INPUT
PRESS/REL
:MOD1
INPUT
SU/WI
:MOD1
INPUT
REVERS.
:MOD1
DIAGNOSIS
Scrollupthroughmenu:
+ >
2 s
ec.
Scrolldownthroughmenu:
- >
2 s
ec.
ReturntoAUTOMATICmode:
P
Onl
y qu
erie
s ar
e po
ssib
le.
UPPERSW
ITCH
:ON
LOWERSWITCH
:OFF
UPSWITCH
:OFF
PARTUP
:OFF
DOWNSWITCH
:OFF
SKS
:OFF
IMP.INPUT
:OFF
SWITCHCLOCK
:OFF
LIGHTBARR.
:ON
STOPCIRCUIT
:ON
S-POINT1
:ON
S-POINT2
:ON
CYCLE
:XXXX
22 – FS 345 Door Controls / Rev. A 0.0
9. Overview of functions
9.1 Automatic operating mode
Display Description
AUTOMATICOPEN
The door is driven to the OPEN end position
AUTOMATICCLOSE
ThedoorisdriventotheCLOSEDendposition
AUTOMATICSTANDBY
The door stands between the end positions
AUTOMATICOSTANDBY
The door stands at the OPEN end position
AUTOMATICoSTANDBY
ThedoorstandsatthePARTOPENposition("before-endposition"up)
AUTOMATICUSTANDBY
ThedoorstandsattheCLOSEDendposition
AUTOMATICuSTANDBY
ThedoorstandsatthePARTCLOSEDposition("before-endposition"down)
GB
FS 345 Door Controls / Rev.A 0.0 – 23
9.2 Input operating mode
Function Description Setting options Factory settings
GERMAN Selectthemenulanguage DEUTSCHENGLISHFRANCAISNEDERLANDSESPANOLPOLSKICESKY
DEUTSCH
RUNTIME Monitoring the maximum running time for an open and closing movement. 1 – 250 seconds 60 seconds
OPEN TIME Afterthedoorhasopened,itrunsbackintheCLOSEdirectionafterthesettimehaselapsed.Open time > 0 = impulse functions only work in the OPEN direction
0 – 600 seconds 0=Autocloseoff
PREWARN-ING
Thewarninglightflashesbeforethedoorstartstoclose.Thepresetwarningtimeisonly active if the open time is > 0 or if operated via radio impulse.
0 - 120 seconds 0 = Off
REVERS.TIME
Standingtimeateverychangeofdirection 0.1 - 2.0 seconds (in1/10seconds)
0.3 seconds
MOD 1-3 STANDBY
MOD1: When resting OFFMOD2: When resting ON
MOD1MOD2
MOD1
QUICKCLOSE
ON: The open time is cut short after the photoelectric barrier has been passed (door closes immediately).OFF: The open time continues as usual.
ONOFF
OFF
RELAY1 Arelaymodulefrom1-18canbeassignedtothefirstthreerelays.MOD1:RedlightisonduringdoormovementandflashesasadvancedwarningMOD2:RedlightflashesduringdoormovementandflashesasadvancedwarningMOD3:RedlightflashesduringdoormovementandflashesasadvancedwarningTheparameterM3–1STAND.affectsthese3MOD.MOD4: Impulse when there is an OPEN commandMOD5: Error messageMOD6: OPEN end positionMOD7:CLOSEDendpositionMOD8: OPEN end position negatedMOD9:CLOSEDendpositionnegatedMOD10: Before-end position OPENMOD11:Before-endpositionCLOSEDMOD12:Before-endpositionCLOSEDtoCLOSEDendpositionMOD13: Magnetic lock functionMOD14 BrakeMOD15: Brake negatedMOD16: Brake remains ON during open timeMOD17: Brake remains ON during open time and direction turnaround (withaCESD(SKS)thebrakeisdeactivated)MOD18:RedlightflashesasawarningMOD19:CESD(SKS)
MOD1 – MOD18 MOD6
RELAY2 MOD1 – MOD18 MOD7
RELAY3 MOD1 – MOD18 MOD1
RELAY4 MOD 19 MOD19
DW-TEST ON: Pressure switch testing is active OFF: Pressure switch testing is not active
ONOFF
OFF
DELAYOPEN
ON: Gives warning before openingOFF: Immediate opening
ONOFF
OFF
24 – FS 345 Door Controls / Rev. A 0.0
Function Description Setting options Factory settings
PRESS/REL MOD1:AutomaticoperationMOD2:ManualoperationforOPEN+CLOSEMOD3:ManualoperationforCLOSE
MOD1 – MOD2 MOD1
SU/WI MOD1:PARTOPENatterminalblockX4(9/10)MOD2:PARTOPENselectorswitchatterminalblockX4(9/10)Whentheselectorswitchisclosed,allOPENcommandsgotothepre-limitswitchOPEN.
MOD1 – MOD2 MOD1
REVERS. MOD1:Thedoordoesnotreversewhenthepre-limitswitchCLOSEisactivated.MOD2:Thedoordoesnotreverse,evenifthepre-limitswitchCLOSEisactivated.
MOD1 – MOD2 MOD1
9.3 Diagnosis / error memory operating mode
Display Meaning Status
UPPERSWITCH OPEN end position OFF: activatedON: not activated
LOWERSWITCH CLOSEDendposition OFF: activatedON: not activated
UPSWITCH UPswitch ON: activatedOFF: not activated
PARTOPEN PARTOPENbutton ON: activatedOFF: not activated
DOWNSWITCH DOWNSWITCH ON: activatedOFF: not activated
SKS Closing edge safety device ON: circuit closedOFF: interrupted (fault)
IMPULSE Impulse button ON: activatedOFF: not activated
SWITCHCLK. Weekly timer ON: activatedOFF: not activated
LIGHTBARR. Photoelectric drive-through barrier ON: circuit closedOFF: interrupted (fault)
STOPCIRCUIT -Stopbuttononthecontrol-Stopsystemsintheoperator
ON: circuit closedOFF: interrupted (fault)
S-POINT1 -Stopbuttononthecontrol (keypad on cover)
OFF: activatedON: not activated
S-POINT2 Pre-limitswitchCLOSE OFF: activatedON: not activated
CYCLE Door cycle counter Displays number of door cycles
Overview of functions
GB
FS 345 Door Controls / Rev.A 0.0 – 25
9.4 LED indications of the FS101
TheFS345controlunitisequippedwitharowofLEDsthatindicatethecurrentoperatingstatusofthesystemandindicateanyfaultsthat may occur. The following table gives an overview of the various faults and status conditions.
K04 K05 K06 K07 K08 K09
K10
K11
K12
FS
10
1-P
1-1
D018 D017 D016
D02 D01 D03
D04 D05D06 D07 D08 D09
D010 D011
D012
D013
D014
D015
D019
9.5 LED diagnostic FS 101
Code Colour Description Error diagnosis
D01 yellow LED safety circuit (inputX03/1,2)
LED ONLED OFF
OK- No power supply from mains or rechargeable battery - Operator safety circuit interrupted
D02 yellow LED limit switch OPEN (inputX03/3,4,5)
LED ONLED OFF
LimitswitchOPENnotconfirmedLimitswitchOPENconfirmed
D03 yellow LEDlimitswitchCLOSED (inputX03/6,7,8)
LED ONLED OFF
LimitswitchCLOSEDnotconfirmedLimitswitchCLOSEDconfirmed
D04 yellow LED auxiliary motor (outputX04/1,2)
LED ONLED OFF
AuxiliarymotorisactiveAuxiliarymotor24VDCisnotactive
D05 yellow LED motor brake (output X04/3,4)
LED ONLED OFF
Motor brake is switched onMotor brake is switched off
D06 yellow LEDdrivecommandopen/close (outputX04/5,6)
LED ONLED OFF
Drivecommandopen/closeonCS300FSisactiveDrivecommandopen/closeonCS300FSisnotactive
D07 yellow LED limit switch OPEN (outputX05/1,2)
LED ONLED OFF
LimitswitchOPENnotconfirmed-LimitswitchOPENconfirmed- Emergency operation is active
D08 yellow LEDlimitswitchCLOSED (outputX05/3,4)
LED ONLED OFF
LimitswitchCLOSEDnotconfirmedLimitswitchCLOSEDconfirmed
26 – FS 345 Door Controls / Rev. A 0.0
Code Colour Description Error diagnosis
D09 yellow LED stop circuit (outputX05/5,6)
LED ONLED OFF
OK-Nopowersupplyfrommains/rechargeablebattery-Safetycircuitondriveunitinterrupted - Emergency operation is active
D010 yellow LEDCS300FSOPEN (inputX05/7,8)
LED ONLED OFF
DoorismovingtowardsOPENin400VoperationDoorisnotmovingtowardsOPENin400Voperation
D01 yellow LEDCS300FSOPEN (inputX05/9,10)
LED ONLED OFF
DoorismovingtowardsCLOSEDin400VoperationDoorisnotmovingtowardsCLOSEDin400Voperation
D012 yellow LEDfiredetector (inputX06/1,2)
LED ONLED OFF
Fire detector is closedFire detector is open (observe DIP 2 )
D013 yellow LEDoperation/fault (outputX07/3,4)
LED ONLED OFF
Operation/nofaultBatteryfault,mains
D014 yellow LED emergency operation (outputX08/1,2)
LED ONLED OFF
Emergency operation is active Emergency operation is not active
D015 yellow LEDSKS (outputX09/1,2)
LED ONLED OFF
SKSisOK SKSisinterrupted
D016 green LED charge maintenance LED ONLED OFF
Storagebatteryischarged,maintenancephaseStoragebatteryischarging
D017 yellow LED charge status LED ONLED OFF
Charging period Not in a charging period - battery charged
D018 red LED battery fault LED ONLED OFF
Batterydefective,CHANGEBATTERY!BatteryOK
9.6 Diagnostic LED D019 F101
Code D 019, colour red
Diagnostic LED (red) Error / status / info Action
Flashes once Battery fault Rechargeable battery is defective: replace
Flashes 2 times Mains power failure BatterychargerDef.;FS101fuseF2Def.
Flashes 3 times CommandreceivedfromfirealarmorfromT1,thedoorwillclose
Flashes 4 times DoorhasbeenclosedbythefirealarmorbyT1
Flashes 5 times SafetycircuitinputX03/1+2hasbeeninterrupted Check the safety circuit of the door operator
Flashes 6 times HYleak(versionFS345HY)) Check the hydraulic system
Flashes 7 times SKSdefectiveatOPENendposition CheckSKS
Flashes 8 times Door has been closed due to an error
Overview of functions
GB
FS 345 Door Controls / Rev.A 0.0 – 27
Error diagnosis CS 300 FS
Code Colour Description Error diagnosis
H4 green LED closing edge safety deviceLED ONLED OFF
OK- Closing edge safety device interrupted- Closing edge safety device defective
Fault / error message Cause RectificationSystemdoesnotrespond - No voltage supply Check the voltage supply to the operator and the
controlDoortravelstotheCLOSEDendpositionwhentheUPbuttonispressed
-Rotatingfieldisconnectedwrongly -Checktherotatingfieldandsettoclockwiserotatingfield,ifnecessary
ERRORENDPOS. -TheOPENandCLOSEDlimitswitchesarebothopen,althoughatleastonelimitswitchshouldbe closed
ChecktheconnectionatX11Check the limit switch connectionsCheck the limit switch settings
ERRORRUNTIME The programmed running time has been exceeded Check the path of the doorRe-programme the running time
ERRORSKS The closing edge safety edge is faultyThe closing edge safety device was activated
Check the closing edge safety device and the spiral cableRemove obstruction from path of door
ERRORPRESSURESWITCHTESTING The pressure sensor is not triggered at the CLOSEDendposition
Checkthepressuresensor,spiralcableandprofileCheckthesettingfortheCLOSEDendposition
Battery Standby
No mains power supplyEmergency operation
Checkmainspowersupply(L,N)
28 – FS 345 Door Controls / Rev. A 0.0
9.7 Adjustment options for TIME 1 (door closes if the mains supply fails)
Withtimer1,thecontrolcandelaytheautomaticclosingofthe door after mains power failure by a set period. When set to0,thedoordoesnotcloseautomaticallyintheeventofmains failure.If the timer is set to 0 and the mains supply is cut off for a longerperiod,thedeepdischargeprotectionsystemforthecontrolcomesintoplay.See17.1.
0 - No automatic closing in the event of mains failure1 - In the event of a power cut: closes after 5 seconds2 - In the event of a power cut: closes after 15 seconds3 - In the event of a power cut: closes after 30 seconds4 - In the event of a power cut: closes after 1 minute5 - In the event of a power cut: closes after 2 minutes6 - In the event of a power cut: closes after 5 minutes7 - In the event of a power cut: closes after 15 minutes8 - In the event of a power cut: closes after 30 minutes9 - In the event of a power cut: closes after 60 minutes
9.8 Automatic mode with active closing edge safety device in emergency operation
It is possible to monitor emergency operation with a contact bar.Ifthecontactbaristriggered,thedoorstopsinemergen-cyoperation.Afterthecontactbarisfreeagainandadelayof2secondshaselapsed,emergencyclosingiscontinued.Reversing does not take place. The function of the closing edgesafetydevice(SKS)ischeckedintheupperendposition.Ifadiscernibleerrorisdetected,emergencyoperationtakesplacewithoutanevaluationoftheSKS.
Prerequisites: − CS300FSisconnectedtoFS101(seedrawing) − Relay mode 19 is set for relay 4 (factory setting) − FS101DIPswitch4isON(switchoffmainsvoltageand
battery power) − CESD(SKS)isconnectedtoterminalX4ofCS300FS
Connection between CS 300 FS + FS 101
7
8
X5
K05 K06 K07 K08 K09
+
-24VDC
Relay 4
CS 300 FSBatteryFS101
Overview of functions
GB
FS 345 Door Controls / Rev.A 0.0 – 29
9.9 Emergency closing with 400 V DC opera-tor
It is possible for the door to be closed using the door operator whenthefirealarmisactivated.
Prerequisites:− ConnectCS300X3/9+10toFS101X04/5+6.− FS101DIPswitch3isON(switchoffmainsvoltageand
battery power)
Connect CS 300 FS circuit board +
9
10
5
6
X3 X04CS 300 FS FS101
Inthiscase,ifasignalisgivenbythefirealarmandmainspowerisavailable,theFS101circuitboardgivesaDOWNim-pulse �X3totheCS300FScircuitboardviaterminalX06.ThedoorisdriventotheCLOSEDendpositioninimpulsemode. The safety devices integrated are active. Once the CLOSEDendpositionhasbeenreached,thedoorcannotbeopened again. IftheCESD(SKS)isactivatedduringtheclosingphase,thedoorreversesandstopsattheOPENendposition.After30secondsafurtherDOWNimpulseissent.IftheCESD(SKS)interruptstheclosingphaseagain,theprocessisrepeated3timesintotal.IftheCLOSEDendpositionhasnotbeenreachedafter90seconds,thedooristhenclosedviaemer-gency operation mode.
9.10 Door sealing function for FT fire door operators
To ensure that the sections of the door close together tightly inemergencymode,thedoormustbedrivenbeyondtheCLOSElimitswitch.WiththeFS345control,thisfunctionistimecontrolledandissetusingTIMER2.Avalueof0to5secondscanbeselected.
Prerequisites: − Door operator type FT (DIP 1 is set to ON) − The system has been set in operation and the limit switches
have been set.
Settings:1. OPENandCLOSElimitswitchesaresetfornormal door operation.2. Settimer2tothemid-rangevalueof2.5seconds.3. Drive the door to the OPEN end position.4. Switchoffthemainsvoltagesupplyandpressthe TESTbutton.5. ThedoorrunstotheCLOSEDendpositioninemer gency operation mode.6. ThedooristhendrivenbeyondtheCLOSElimitswitch for 2.5 seconds. Only then is power supplied to the motor brake again and the door is held in position.7. Repeat steps 2 to 6 entering different values for timer 2 until optimum results are achieved.8. TheCLOSEsafetylimitswitchmustbesetaccordingly.
30 – FS 345 Door Controls / Rev. A 0.0
TheFS345controlunitaffordsprotectionagainstdeepdis-charge of the battery and can carry out regular tests to check the condition of the battery.
10.1 Checking the rechargeable battery and emergency operation
� Toensurethatthesystemalwaysfunctionsconsistently,thefirealarmfunctionmustbecheckedonceeveryfourweeks.In order to check at the same time that the rechargeable batteryalsofunctionscorrectly,thecontrolmustbediscon-nected from the mains. This is the only way to demonstrate that the emergency function is operational and that the door closes automatically via the auxiliary motor.
Procedure: − Drive the door to the OPEN end position.− Switchoffthemainspowersupply.− PressTESTbutton:Emergencyoperationisstartedaftera
delay of 2 seconds.
Check:afterpressingtheTESTbutton
1. the battery test is started � LED indicator
2. The integrated buzzer sounds3. After2seconds,thedoorisdriventotheCLOSEDend
position4. The buzzer stops5. � LED indicator
6. The buzzer sounds once7. The test is over
10. Rechargeable battery and battery charger
9.11 Integrated buzzer and RESET buttonTheFS345controlunithasanintegratedbuzzerthatgivesan acoustic signal to indicate emergency operation and the condition of the rechargeable battery.
The buzzer sounds during emergency closing and stops when itreachesitsCLOSEDendposition.The alarm also sounds if a faulty battery is detected during operation or during a test.The acoustic warning signal can also be switched off using theRESETbuttonintheCLOSEDdoorposition.Thebatteryneeds to be changed.
Buzzer1 tone sounds at intervals of 5 seconds
No mains voltage
1 tone sounds at intervals of 2 seconds
Rechargeable battery is defective
4 short tones Warning before emergency closing
1 tone sounds at intervals of a second
Emergency closing
Overview of functions
GB
FS 345 Door Controls / Rev.A 0.0 – 31
10.2 Protection against deep discharge
If,followinginitialoperation,thecontrolisoperatedforalengthyperiodwithoutanexternalpowersupply,thecontrolisswitchedoffafteradefinedperiodtopreventdeepdischarging of the battery. The period of time depends on the type of operator and so from the external consumer devices.
DIP1ON Switchesoffafter8hourswithoutexternal mains supply voltageDIP1OFF Switchesoffafter48hourswithoutexternal mains supply voltage
The buzzer sounds continuously for 60 seconds to signal that thebattery,andthereforealsothecontrolunit,hasbeenswitched off.
If timer 1 is to be set to nought (door does not close if mains powerfails),thedoorclosesinacontrolledmannerorisleftopen depending on the setting of DIP switch 5. It is only pos-sible to keep the door open in a controlled way if DIP switch 1 is OFF:
DIP5ON Doorclosesafterthesignalbuzzersounds, thebattery/controlisswitchedoffDIP5OFF Doorremainsopen,thebattery/controlis switched off
The control can only be switched on again if the external volt-age supply is reconnected.
For FT types of operator (DIP 1 ON), if the mains sup-ply has been interrupted for a period of 8 hours or longer, the battery is charged for 30 minutes as soon as the mains voltage is switched back on. The door control cannot operate during this charging period.This charging status is indicated via the recharge LED and can be interrupted by pressing the RESET button.
Lights up Flashes
alternately
10.3 Cyclic testing of the rechargeable battery
TheFS345controlisabletotesttheconditionoftherechargeablebatteryautomatically.Innormaloperation,thebattery is disconnected from the control every 60 minutes and the battery voltage is checked.
Ifthebatteryvoltagefallsbelowaspecifiedvalue(19V),thisisrecognisedasafault,whichisthenindicatedviathefaultrelay,thebuzzerandthediagnosticLED.Itcouldbethat proper operation in emergency mode is then no longer possible.
DIP switch 5 can be set to specify whether the door closes or stays open in this case.
DIP5ON Thedoorcloses,thebatteryisswitchedoffDIP5OFF Doorremainsopen,thebattery/controlis switched off
Connection between CS 300 FS + FS 101
9
10
5
6
X3 X04CS 300FS FS101
DIP 5 ON
123
4
ON OFF
5
6
32 – FS 345 Door Controls / Rev. A 0.0
NOTICE
Damage due to improper use of charging device!TheFS101circuitboardchargerissuitableforchargingmaintenance-free lead batteries only. The battery charger may only be opened by authorised persons and must only be used if closed.The warranty will be invalid if the charging device becomes damaged due to improper opening.Ensure that there is adequate ventilation before using the deviceforthefirsttime.The device must only be used in closed rooms and must not be exposed to dampness and humidity.Alterations of any kind to the device will invalidate the warranty.
10.4 Recharging the battery
NOTICE
Incorrect charging of maintenance-free lead batter-ies may result in faults or failures!Before not using for any length of time (two options)
− Disconnect your battery from the charger and store the battery in its fully charged state
(if not using for more than three months, charge for at least 36 hours)
− Youcancontinuetochargeyourbatteryindefinitelywiththe battery charger switched on (maintenance charging). We recommend storing the batteries in a cool room.
High temperaturesCharging the battery at temperatures of over 30°C is not recommended.Yourbatterychargerisfactorysettoacharging voltage which is designed for an ambient tem-perature of 20°C.
Low temperaturesCharging the battery at temperatures under 10°C is not recommended.Atlowtemperatures,theavailablecapacityis reduced.
Deep dischargePlease avoid deep discharging of your battery. If deep batterydischargeoccurs,however,replacethebatteryim-mediately.
CAUTION!
Risk of injury through use of charging devices! − (due to the formation of explosive gases when charging
lead-acid batteries) − Dangeroffireandshort-circuit(due to electric shock in
moist conditions)To prevent any danger:
− Ensure that the area is adequately ventilated. − Avoidfireandnakedlights. − Usetheplug-inpowerpackonlyindryrooms. − Protect the device from moisture.
Battery and battery charger
GB
FS 345 Door Controls / Rev.A 0.0 – 33
34 – FS 345 Door Controls / Rev. A 0.0
11.1 Motor brake connection diagram for FT 3 / FT 4 / FT 5 operator
CS300FS auxiliary mains adapter24VDC
24VDCmo-tor brake
11. Motor brake and auxiliary motor
L NNL1
+ -
X12
K14
K13
K13 K14
1 2X13
GB
FS 345 Door Controls / Rev.A 0.0 – 35
11.2 Auxiliary motor connection diagram for FDF 60 operator
12-+
M
BatteryFDF 60
auxiliary motor power relayauxiliary motor
36 – FS 345 Door Controls / Rev. A 0.0
12. Technical data
12.1 Mechanical and electrical data
Housingdimensions: 750 x 300 x 132 mm
Installation: Verticalmountingonthewall, minimumheightabovefloor=1,100 mm
Supplyvoltage: 3~400VAC,50Hz,+/-10%STANDARD3~230VAC,50Hz,+/-10%SPECIALSOLU-TIONOther voltages on request
Fuse protection: 10AKtype
Power input: Max. 2.2 kW
Internal consumption of control:
Max.powerconsumptionoftheCS300FScontrolitself=250mAonsecondarysideMax.powerconsumptionoftheFS101controlitself=200mAonsecondaryside
Motor data: max.2.2kWAC/-3.2A.
Control voltage: 24VDC,allinputconnectionsmustbepotential-free;minimumsignaldurationforinput control command >100 ms
Control outputs: 24VDC,maximumof500mA
Batteries Maintenance-freebatterieswithVdScertifica-tion
Fault output relay: If inductive loads are connected (e.g. further relaysorbrakes),thesemustbefittedwithap-propriatesuppressorelements(recoverydiodes,varistors,RCcircuits).Potential-freenormallyopencontact;min.10mA;max.230V230VAC~4AOnce contacts have been used for power cir-cuits,theycannolongerbeusedforextra-lowcurrent circuits.
Emergency operation output relay:
If inductive loads are connected (e.g. further relaysorbrakes),thesemustbefittedwithap-propriatesuppressorelements(recoverydiodes,varistors,RCcircuits).Potential-freenormallyopencontact;min.10mA;max.230V230VAC~16AOnce contacts have been used for power cir-cuits,theycannolongerbeusedforextra-lowcurrent circuits.
Temperature range: Operation: +5°C…+55°CStorage: -20°C…+85°C
Airhumidity: Upto80%withnocondensation
Vibrations: Low-vibrationmounting,e.g.onamasonrywall
Type of protection: IP 54
Weight: approx. 10.5 kg
13. Maintenance
TheFS345controlismaintenance-free.
DANGER!
Life-threatening danger due to electric shock! � ThecontrolunitordoorsystemMUSTbedisconnectedfrom the electricity supply before carrying out any electri-cal work. Take measures to ensure that the power supply remains disconnected for the duration of the work.
The following points must be taken into account when carry-ing out maintenance on the door system:Maintenance must only be carried out by authorised persons.DirectiveASRA1.7mustbecompliedwith.Worn or faulty parts must be replaced.Only approved parts may be installed.Allmaintenanceworkmustbedocumented.Replaced fault parts must be disposed of properly in accord-ance with the materials they contain and local regulations.
GB
FS 345 Door Controls / Rev.A 0.0 – 37
14. EC Declaration of Incorporation
We hereby declare that the product described below:FS 345 Door Controlis in conformity with all essential requirements of the Machin-eryDirective2006/42/EC.
Inaddition,thepartlycompletedmachineryisinconformitywithallregulationsoftheEUConstructionProductsRegula-tionNo.305/2011,theElectromagneticCompatibilityDirective2004/108/ECandtheLowVoltageDirective2006/95/EC.
The following standards were applied:
EN 60204-1Safetyofmachinery,electricalequipmentofmachines;Part1:General requirements
ENISO12100Safetyofmachinery–generalprinciplesfordesign-riskas-sessment and risk reduction
DIN EN 12453Safetyinuseofpoweroperateddoors-Requirements
DIN EN 61000-6-2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
DIN EN 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Genericstandards-Emission-standardforresidential,com-mercial and light-industrial environments
DIN EN 60335-1Householdandsimilarelectricalappliances-Safety-Part1:General requirements
DIN EN 60335-2-103Householdandsimilarelectricalappliances-Safety-Part2-103:Particularrequirementsfordrivesforgates,doorsandwindows
The relevant technical documentation is compiled in ac-cordancewithAnnexVII(B)oftheECMachineryDirective2006/42/EC.Weundertaketotransmit,inresponsetoareasonedrequestbythemarketsurveillanceauthorities,thisinformation in electronic form within a reasonable term.
Person authorised to compile the relevant technical documen-tation: MFZAntriebeGmbH&Co.KG,NeueMühle4, D-48739 Legden The machinery is incomplete and must not be put into service until the machinery into which it is to be incorporated has been declared in conformity with the provisions of the Ma-chineryDirective2006/42/EC.
Place / Date:Legden,01/03/2014
Manufacturer’s signature
Dirk Wesseling
Position of signatoryManagement