IM 05P01C81-41EN page 1/2
Contents1. Safety Precautions2. ModelandSuffixCodes3. How to Install4. HardwareSpecifications5. Terminal Wiring Diagrams6. 920MHzWirelessCommunication
IntroductionThankyouforpurchasingtheUT52A/MDL,UT32A/MDLController.The UT52A-00B-11-00/x/MDL and UT32A-00B-11-00/x/MDL controllers can only be used in the US.The UT32A-00C-11-00/x/MDL controller can only be used in the Republic of Korea.This operation guide describes the installing, wirings, and setup flow related to the wireless communicaiton function of the UT52A/MDL and UT32A/MDL. For configuring the 920 MHz wireless communication and descriptions not covered in this manual, see the 920 MHz Wireless Communication User’s Manual (IM 04L51B01-41EN), provided as an electronic manual.The guide should be provided to the end user of this product. Be sure to read this operation guide before using the product in order to ensure correct operation.Beforeusingtheproduct,refertothetableofModelandSuffixCodestomakesurethatthedeliveredproductisconsistentwiththemodelandsuffixcodesyouordered.Also make sure that the following items are included in the package.
1. Safety PrecautionsThe following symbol is used on the instrument. It indicates the possibility of damage to the instrument,andsignifies that theusermust refer to theoperationguideoruser’s manual for special instructions. The same symbol is used in the operation guide and user’s manual on pages that the user needs to refer to, together with the term “WARNING”or“CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious or fatal injury to the user, and indicates precautions that should be taken to prevent such occurrences.
CAUTION
Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates precautions that should be taken to prevent such occurrences.
■ Noteson920MHzWirelessCommunication• 920 MHz wireless communication can be used only in the US or Korea.• OnlyUSFCCstandardsandULstandardsorKoreaKCmarkingaresupported.• ThisproducthasobtainedFCCcertificationorKCmarking.Assuch,thefollowing
acts may be punishable by law. •Disassembling or altering the product •Removingthecertificationlabel •Usinganantennaotherthanthespecifiedoption• Communicationmaynotbepossibleinthefollowinglocationsduetoradiosignal
reflection. •Wherestrongmagneticfield,staticelectricity,orradiointerferenceoccurs •Rooms with metallic walls (including concrete containing metal reinforcement
material), inside cabinets, etc.• If another wireless device using the same radio frequency band as this product
is present in the communication area of this product, data rate degradation or communication errors may occur, preventing normal communication.
• Because this product uses radio signals, bear in mind that communication may be intercepted by third parties.
• Communicationerrorscanoccurwhenwirelesscommunication is temporarilyinterrupted due to environmental factors such as radio interference.
■ FCCCAUTION• Changesormodificationsnotexpresslyapprovedby thepartyresponsible for
compliance could void the user’s authority to operate the equipment.• This transmitter must not be co-located or operated in conjunction with any other
antenna or transmitter.• ThisequipmentcomplieswithFCCradiationexposure limitsset forth foran
uncontrolledenvironmentandmeets theFCCradio frequency(RF)ExposureGuidelines.ThisequipmenthasverylowlevelsofRFenergythatisdeemedtocomplywithouttestingofspecificabsorptionrate(SAR).
Notice NORIGHTSORLICENSES,EXPRESSOR IMPLIED,AREGRANTEDTO
USETHIRD-PARTYDEVICESINCOMBINATIONWITHTHESEPRODUCTSINAWIRELESSMESHNETWORK,ORTOUSETHIRDPARTYSERVICESTOACCESS,MONITORORCONTROLTHESEPRODUCTSINAWIRELESS
MESHNEWORKVIATHEINTERNETORANOTHEREXTERNALWIDEAREANETWORK.
Patent Marking Coveredbyoneormoreclaimsofpatents:http://sipcollc.com/patent-list/and
http://intusiq.com/patent-list/.
WARNING
Using920MHzwirelesscommunicationl Do not install or use inside aircrafts or hospitals or in areas
wheretheuseofwirelessdevicesisprohibited.l Do not install or use near automatic doors, fire alarms, and other
automatically controlled equipment. Theradiosignals fromthisproductmayaffect theequipment
and may cause a malfunction.l Do not install or use near cardiac pacemakers or electronic
devices that involve highly accurate control or minute signals. Doing so may cause them to malfunction.l Do not use the product in medical equipment or other
applications that require high level of safety or in systems (e.g., trunk line communication equipment, computer systems) that require extremely high reliability.
Malfunction or failure may cause life-threatening accidents or great social disruption.
CAUTION
This instrument is an EMC classA product. In a domesticenvironment thisproductmaycauseradio interference inwhichcase the user needs to take adequate measures.이 기기는 업무용 ( A급 ) 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 , 가정외의 지역에서 사용하는 것을 목적으로 합니다 .
2. ModelandSuffixCodes■ UT52A«StandardCodeModel»
Model Suffixcode Optioncode Description
UT52A /MDL(Required)
DigitalIndicatingController(Powersupply:100-240VAC)(providedwithretransmissionoutputor15VDClooppowersupply,3DIs,and3DOs)(*1)
Type1:Basic control
-0 Standard type
Type2:Functions 0 None
B Wireless communication (with serial gateway function)(*2)
Fixedcode -1 Temperatureunit:degC°FCasecolor 1 Black (Light charcoal gray)Fixedcode -00 Always "-00" (for standard code model)
Optioncodes
/MDL(Required)
Mount on DIN rail (without the display parts and keys)(*3)
/DC Powersupply24VAC/DC/CT Coating(*4)
*1: UT52Ahasapanelmounttype(withoutoption/MDL).PleaseseetheOperationGuide(IM05P01C31-11EN).
*2: UT52A-00B-11-00/x/MDLcanonlybeusedintheUS. When the wireless communication is specified, the UT52A does not conform to the safety standard(CSA)andCEmarking(UT52A-00B-11-00/x/MDLisnotintendedforEEA-market).
*3: Whenthe/MDLoptionisspecified,themodelandthesuffixcodesareasfollows: UT52A-00B-11-00/x/MDL*4: Whenthe/CToptionisspecified,theUT52Adoesnotconformtothesafetystandards(UL
andCSA)andCEmarking(Productswith/CToptionarenotintendedforEEA-market).
■ UT32A/MDL«StandardCodeModel»Model Suffixcode Option
code Description
UT32A /MDL(Required)
DigitalIndicatingController(Powersupply:100-240VAC)(providedwithretransmissionoutputor15VDClooppowersupply,2DIs,and3DOs)(*1)
Type1:Basic control
-0 Standard type
Type2:Functions 0 None
Type3:Opennetworks
B Wireless communication (with serial gateway function)(*2)<FortheUS>
C Wireless communication (with serial gateway function)(*3)<FortheRepublicofKorea>
Fixedcode -1 Temperatureunit:degC°FCasecolor 1 Black (Light charcoal gray)Fixedcode -00 Always"-00"(forStandardCodeModel)
Optioncodes
/MDL(Required)
Mount on DIN rail (without the display parts and keys) (*4)
/DC Powersupply24VAC/DC/CT Coating(*5)/CV Terminal cover
3. HowtoInstall
■ External Dimensions
Whenusingthesleeveantenna
120(
4.72
) or m
ore
150(
6) o
r mor
e
6.8 (0.28)48.2 (1.90)
1.6 (0.06)15 (0.59)
91.6
(3.6
1)94
.6(3
.72)
Mini-USB cable
DIN railTH35-7.5
Cable for LL50A
Minimum cable curvature: R40 (1.57)
100
(3.9
4)11
4(4
.49)
4(0.
16)
100 (3.94)20 (0.79) 4.3 (0.17)
60 (2.36)
61.1 (2.41)
303 (11.93) or less
209
(8.2
3) o
r les
s38
.6(1
.52)
141 (5.55) or less
0 to 9
0°
Note:TrigonometryGeneral tolerance = ±(JIS B 0401-1998 tolerance class IT18)/2
Unit: mm (inch)
Terminal cover
(req
uire
d fo
r ins
ertin
g/re
mov
ing
the
Min
i-US
B c
able
)(r
equi
red
for i
nser
ting/
rem
ovin
g th
e ca
ble
for L
L50A
)
Whenusingtherooftopantenna
Mini-USB cable
DIN railTH35-7.5
Minimum cable curvature: R40 (1.57)
94.6
(3.7
2)
91.6
(3.6
1)
4(0.
16)
61.1(2.41)
60
Cable for LL50
(2.36)
20(0.79) 100(3.94) 4.3(0.17)
114
(4.4
9)10
0(3.
94)
48.2(1.90)6.8(0.28)
15(0.59)
Terminal cover
(req
uire
d fo
r ins
ertin
g/re
mov
ing
the
Min
i-US
B c
able
)(r
equi
red
for i
nser
ting/
rem
ovin
g th
e ca
ble
for L
L50A
)
120(
4.72
) or m
ore
150(
6) o
r mor
e
Unit: mm (inch)
Note:TrigonometryGeneral tolerance = ±(JIS B 0401-1998 tolerance class IT18)/2
OperationGuideIM 05P01C81-41EN
UT52A/MDL, UT32A/MDLDigital Indicating Controller (DIN Rail Mounting and Wireless Communication Type)Operation Guide
4th Edition: Dec. 2019
Manuals can be downloaded or viewed at the following URL.
Functional
Enhancement
http://www.yokogawa.com/ns/ut/im/
«Standard Code Model»
*1: UT32Ahasapanelmounttype(withoutoption/MDL).PleaseseetheOperationGuide(IM05P01D31-11EN).
*2: UT32A-00B-11-00/x/MDLcanonlybeusedintheUS. When the wireless communication is specified, the UT32A does not conform to the safety
standards(CSA)andCEmarking(UT32A-00B-11-00/x/MDLisnotintendedforEEA-market).*3: UT32A-00C-11-00/x/MDLcanonlybeusedinRepublicofKorea. When the wireless communication is specified, the UT32A does not conform to the safety
standards(ULandCSA)andCEmarking.*4: The/MDLoptionisspecified,themodelandsuffixcodesarefollows: UT32A-00B-11-00/x/MDL,UT32A00C-11-00/x/MDL*5: Whenthe/CToptionisspecified,theUT32Adoesnotconformtothesafetystandards(UL
andCSA)andCEmarking(Productswith/CToptionarenotintendedforEEA-market).
■ Accessories(soldseparately)The following is an accessory sold separately.• TerminalCover ForUT52A/MDLandUT32A/MDL (with thewirelesscommunication):Model
UTAP004• Antenna Sleeveantenna(indooruse):Partno.A1061ER Rooftopantenna(indoorandoutdooruse,cablelength:2.5m):Partno.A1062ER• Wall mount bracket ForUT52A/MDLandUT32A/MDL:ModelUTAP005
IM 05P01C81-41EN page 2/2
4. HardwareSpecifications
■ SafetyandEMCStandards• The UT52A/MDL’s 920 MHz wireless communication (with serial gateway function)
and UT32A/MDL’s 920 MHz wireless communication (with serial gateway function) complywiththeUSFCCstandardandareapprovedbyULstandard.
• The UT32A/MDL’s 920 MHz wireless communication (with serial gateway function) complywiththeKCmark.
• Wirelesscommunicationstandard:IEEE802.15.4gcompliant• FCCPart15SubpartCcompliant(§15.247)• KCmarkcertification:KN301489-1/-3,KN11,KN61000-6-2• ULstandard:SeetheOperationGuideforUT35A/UT32A(IM05P01D81-11EN)orUT55A/UT52A(IM05P01C81-11EN).
■ Construction• Externaldimensions(mm): UT52A/MDL (with the wireless communication) and UT32A/MDL (with the wireless communication):48.2(width)x114(height)x104(depth)
■ Isolation• Isolationspecifications
USB port for 920 MHz wireless communication configurationPV (universal ) input terminals / maintenance port
Control relay (contact point c) output terminals
Alarm-1 relay (contact point a) output terminals
Alarm-2 relay (contact point a) output terminals
Alarm-3 relay (contact point a) output terminals
Contact input terminals (all)RS-485 communication terminals
Control, retransmission (analog) output terminals(not isolated between the analog output terminals)
Internalcircuits
Powersupply
The circuits divided by lines are insulated mutually.
5. TerminalWiringDiagrams
CAUTION
Do not use an unassigned terminal as the relay terminal.
E1-Terminal Area301-312
RS-485
SDB(+)
SDA(-)
RDB(+)
RDA(-)
SG
(Suffix code: Type 3=B or C)
301
302
303
304
305
RS485
RADIO
ST1
Antenna insertion port
ST2GreenRed
GreenRed
920 MHz wireless communication (with gateway function)
6. 920MHzWirelessCommunication
ComponentNamesofUT52A/MDL,UT32A/MDL(with920MHzwirelesscommunication)
ST1
ST2Status LEDST1(green/red)ST2(green/red)
Device front side
Rebootswitch
USB port for 920 MHz wirelesscommunication configuration
Device bottom side
Preparation,Configuration,andOperationCheckToconfigure(Modbussettings,wirelesscommunicationsettings)oftheUT52A/MDLor UT32A/MDL and check the operation of the UT, follow the procedure below.
Donotwriteparameters throughwirelesscommunicationwhilerunning.Useonlyduringmaintenance.
1 Modbuscommunication(serialcommunication)configuration ConfigureModbuscommunicationsettingsbyreferringto thismanual,UT55A/
UT52A User’s Manual or UT35A/UT32A User’s Manual, and 920 MHz Wireless CommunicationUser’sManual(IM04L51B01-41EN).
The UT52A/MDL and UT32A/MDL communication parameter settings are shown below. Do not change them from their default values. If you change them, communication will fail to work properly.
Protocol:Modbus(RTU) Baudrate:9600bps Parity:None Stopbits:1bit Datalength:8bits
2 Maintenance console preparation Download the maintenance console from the following URL, and install it. http://www.smartdacplus.com/software/smart920/en/ *ThemaintenanceconsoleisanapplicationmadebyOkiElectricIndustryCo.,Ltd.
3 Configurationfilepreparation Using themaintenanceconsole,createaconfigurationfileconsistingofbasic
settings, protocols, communication settings, and other wireless network settings accordingtoyourwirelessnetworkconfiguration.
Do not change the wireless serial settings from their default values. If you change them, communication will fail to work properly.
Bitrate:115200bps Bitlength:8bits Stopbits:1bit Parity:None Youcanalsouse themaintenanceconsole toconfigure theUT52A/MDLor
UT32A/MDLdirectlywithoutcreatingaconfigurationfile. Fordetailsonthewirelesscommunicationsettings,seethe920MHzWireless
CommunicationUser’sManual(IM04L51B01-41EN).
4 Wirelesscommunicationconfiguration(networkconfiguration) Connect theUT52A/MDLorUT32A/MDLwirelesscommunicationconfiguration
(networkconfiguration)maintenancePCto theUT52A/MDL’sorUT32A/MDL’swirelesscommunicationconfigurationportwithaminiUSBcable.Then,writetheconfigurationfileintothewirelessmodule.Afterwriting,presstherebootswitchon the UT52A/MDL or UT32A/MDL or remove the mini USB cable to restart the system and apply the settings. (Hold down the reboot switch for several seconds untilthestatusLEDturnsoff.)
5 Networkjoinconfirmation WhentheUT52A/MDLorUT32A/MDL joinsanetwork,* thegreenstatusST1
LEDblinksslowly,andthegreenST2turnson. *Turntherouters(UT52A/MDLsorUT32A/MDLs)onafterstartingthecoordinator(GM10/
CM2,GX20/CM2,GM10/CM3,GX20/CM3,orthelike).Thiswillmakenetworkconnectionauthentication quicker.
Connectionto theUSBPort for920MHzWirelessCommunicationConfiguration
A USB2.0 port (mini B type) is available. Itisforconfiguringthe920MHzwirelesscommunication.
Status LED Indication (*1)
ST1
ST2GreenRed
GreenRedName LEDdisplay Status Notes
Green RedST1 Blinking in sync at 1 second
intervalsUpdating firmware Transferring files
On On OpeningfilesBlinking at 0.2 second intervals
Off Normal Not joined the network
Blinking at 1 second intervals
Off Normal After IP is established upon joining network
Off Blinking at 1 second intervals
Failure
Alternate blinking of green and simultaneous green and red at 1 second intervals
Radio transmission time exceeded
ST2 On Off Network join authentication success/normal
Off Blinking at 1 second intervals
Network join authentication failure*2
Blinking in sync at 1 second intervals
Nodetourroute*2
Alternate blinking at 1 second intervals
Wireless stopped
Blinking Off Transmitting/receiving serial communication
Off Off Not joined the network or disconnected from network
*1Theabovetabledoesnotapplywhendeterminingtheradioconditionusingthemaintenanceconsole software.
*2Systemerrorstatus.Usingthemaintenanceconsole,correcttheinstallationenvironment(suchas the antenna direction) to an appropriate condition.
ConnectinganAntennatotheUT52A/MDLorUT32A/MDL
Sleeve antennaSleeve antennas (not waterproof) are used indoors or inside a case. Sleeve antennas do not have directivity. They can also be bent and rotated to change the antenna direction. As such, they can be used anywhere indoors.While turning the antenna to the right, attach the antenna to the antenna connection port.
Antenna connection port
Sleeve antenna
Roof top antennaRoof top antennas (waterproof) are used when you want to install only the antenna in a remote location.Thereisamagnetonthebottomside,sotheycanbeattachedtometalboxesandthe like.
• Tobringoutthefullperformanceoftherooftopantenna,installit on top of a metal rectangle board that is at least 10 × 20 cm long.
• Install antennas as far as possible from metal objects and other obstacles.Thecommunicationqualitymaydeteriorateiftheyareclose.
• When installing the antenna,makesureno foreignmattergetscaughtbetween thebottomsideof theantennaand theinstallation plane.
• Donotbendtheantennacablemore thantheallowablebendradiusof3cm.
• Wheninstallingtheantennainanareasubjectto lightning,besure to install the antenna at a position safe from lightning and atapositionlowerthantheheightofothercases.
While turning the antenna connector to the right, attach the antenna to the antenna connection port.* Useatorquewrench(wrenchwidth5/16 inches, tighteningtorque0.56to0.90
N•m).
Antenna connection port
Connector
Roof top antenna
• Printed ManualsModel Description
UT52A/MDL,UT32A/MDLDigitalIndicatingController(DINRailMountingandWirelessCommunicationType)
IM05P01C81-41EN
UTAP005 Wall Moount Bracket User's Manual IM 05P06A31-02Z1
• ElectronicManuals Youcandownloadthelatestmanualsfromthefollowingwebsite: URL:http://www.yokogawa.com/ns/ut/im/
Model DescriptionUT52A/MDL,UT32A/MDLDigitalIndicatingController(DINRailMountingandWirelessCommunicationType)
IM05P01C81-41EN
UTAP005 Wall Moount Bracket User's Manual IM 05P06A31-02Z1920MHzWirelessCommunicationUser'sManual IM04L51B01-41EN
• GeneralSpecificationModel Description
UT52A/MDL,UT32A/MDLDigitalIndicatingController(DINRailMountingandWirelessCommunicationType)
GS05P01C81-41EN
UT32A/MDLDigitalIndicatingController(DINRailMountingandWirelessCommunicationType)
GS05P01D81-43EN
* Thelasttwocharactersofthemanualnumberandgeneralspecificationnumberindicatethelanguage in which the manual is written.
CAUTION
CAUTION
www.yokogawa.com/ns
YOKOGAWA ELECTRIC CORPORATIONNetwork Solutions Business Division
2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 JAPANYOKOGAWA CORPORATION OF AMERICA
Head office and for product sales2 Dart Road, Newnan, Georgia 30265, USA
YOKOGAWA EUROPE B.V.Headquarters
Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS
All Rights Reserved, Copyright © 2017 Yokogawa Electric Corporation