View
1
Download
0
Category
Preview:
Citation preview
MS-200™ Installation Guide
TAYLORM E T A L P R O D U C T S
BUTYL INJECTED SEAL(AVAILABLE)
2"
BUTYL INJECTED SEAL(AVAILABLE)
2"
Table of ContentsPanel Specifications ................................................................................ Floating Panel Clip ...................................................................................... Notes To Designer/Installer ......................................................................Taylor Delivery Fleet .................................................................................... Delivery, Will Call & Loading .......................................................................Standard Eave ........................................................................................... Hook Eave ................................................................................................. Gutter/Hook Eave ...................................................................................... Standard Ridge ......................................................................................... Vented Ridge ............................................................................................. End Dam Attachment ................................................................................. Valley Flashing ........................................................................................... Valley Flashing – Low Pitch ....................................................................... Standard Gable .......................................................................................... Alternate Gable ......................................................................................... Sidewall ..................................................................................................... Peak Flashing (R.E.C.) ..............................................................................Vented Peak Flashing (R.E.C.) .................................................................Pitch Change ............................................................................................ Endwall ...................................................................................................... Vented Endwall ......................................................................................... Saw Cut Endwall ....................................................................................... Back Pan ................................................................................................... Curb Side Wall .......................................................................................... Curb End Wall ........................................................................................... Curb/Pan Cricket ....................................................................................... Eave to Gable Transition .....................................................................Pipe Penetration – on Plate ...................................................................... Pipe Penetration – on Rib .................................................................... Pipe Penetration – on Pan ........................................................................
Flashing Selection ................................................................................
MS-200™Flashing and Details Guide
1
2-34
5-789
101112131415161718192021222324252627282930
31-3334
35-3637
38-41
TAYLORM E T A L P R O D U C T S
TAYLORM E T A L P R O D U C T S
MS-200™MECHANICALLY SEAMED
2
• 12", 14-5/8" & 16" options available
• 24 & 22 gauge Tru-Gauge™ and .032" Aluminum
• Floating clip system: allows for expansion/ contraction of panels in longer lengths
• 2" Mechanical seam rib, 90° or 180°: Factory notching available
• Factory injected Butyl sealant
• Structural panel that will span up to 5'
• Concealed fasteners: fasteners cannot leak
• Manufactured in Sacramento, CA & Salem, OR
• - Code compliance UL Evaluation Report UL ER 25913-01
• UL 580 Class 90 Wind Uplift & UL Class A Fire rated
• UL Construction No. 90, 176, 180, 238, and 238A
• ASTM E-1592 - Structural uniform static air pressure ASTM 1646 - Water infiltration ASTM 2140 - Water infiltration ASTM 1680 - Air infiltration
• Weather tightness warrantly available (Contact TMP representative for details)
• 1/2:12 minimum pitch recommended (For lower pitches, please inquire)
• Standard panel lengths 3' to 60' (For longer panels, please inquire)
• 2' Shortcut capability - not notched (Fee applicable)
• Onsite roll forming available for long lengths
• Panel options: Striations, Accent Ribs, and Flat Pan
• Retro-fit systems available
STRIATIONS
ACCENT RIBS 2 Accent ribs for 12" & 14-5/8" panel3 Accent ribs for 16" panel
PANEL PROFILES
KEY FEATURES
BUTYL INJECTED SEAL(AVAILABLE)
2"
BUTYL INJECTED SEAL(AVAILABLE)
2"
90º SEAM DETAL 180º SEAM DETAIL
180 degree seams are not considered an architectural detail. The detail improves the weather tight-ness and wind uplift capabilities of the panel system, but will show stress and waviness in the seam. The detail is recommended for slopes less than 3/12, roof areas not easily viewed from the ground, and for high wind areas. For additional information, contact a TMP representative and DI Seamers for support and information about the proper use of seaming tools.
3
These printed chips provide a close representation of the colors. Metal samples are available upon request. Coatings are low gloss 10-15% sheen.SRI = Solar Reflective Index. SRI values listed above are in accordance with ASTM E 1980 and are based on actual testing.***Oil canning is not a cause for material rejection***
11-20
Kynar 500
Commercial-grade metal primer
G-90 galvanizing
24 or 26 guage steel
G-90 galvanizing
Commercial-grade metal primer
Corrosion resistant primer
Kynar 500® paint layer
Commercial-grade metal primerGalvanized G-90 or AZ-50
Base SteelGalvanized G-90 or AZ-50Commercial-grade metal primerCorrosion resistant wash coat
STANDARD COOL KYNAR 500® COLORS
MATERIAL SPECIFICATIONS• 24 gauge Kynar 500® Painted Steel .0236" (Thickness prior to painting) Galvanized G-90 or AZ-50
• 24 gauge bare Zincalume® Plus AZ-55 (No finish warranty – 25 yr. perforation warranty)
• 22 gauge Kynar 500® Painted Steel .029" (Thickness prior to painting)
• .032" Kynar 500® Painted Aluminum
• 22 gauge Rusteel Plus™ (A606)
• 16 and 20 ounce Copper (Please inquire)
• Kynar 500® and substrate testing data available (See website)
• “Oil canning” is an inherent characteristic of roof and wall products, and not a defect, which is not a cause for panel rejection
KEY FEATURES• 21 Standard Colors, 5 Metallic Colors and 4 Specialized Colors
• Kynar 500® Paint System - the ultimate in exterior durability and color retention
• “Cool” color pigments are specially designed to reflect infrared light, reducing heat gain to dwelling, and conform with ENERGY STAR® criteria
• Superior Quality, two coat, 70% resin finish, applied at a 1 mil. thickness
• 40 year residential paint warranty
• 20 and 30 year commercial paint warranty: Contact TMP for warranty specifications
Gla
cier
Whi
te S
RI-8
5
40-Year Residential / 20 and 30 Year Commercial Manufacturer’s Limited Warranty
Sier
ra T
an S
RI-6
0
Parc
hmen
t SR
I-58
Ster
ling
Gre
y SR
I-44
Zinc
Gre
y SR
I-39
Cha
rcoa
l Gre
y SR
I-25
Sadd
le T
an S
RI-3
7
Med
ium
Bro
nze
SRI-3
6
Mus
ket S
RI-3
1
Dar
k Br
onze
SR
I-22
Taho
e Bl
ue S
RI-3
1
Paci
fic B
lue
SRI-2
6
Hem
lock
Gre
en S
RI-3
6
Fore
st G
reen
SR
I-24
Pine
Gre
en S
RI-2
5
Terra
Cot
ta S
RI-4
3
Tile
Red
SR
I-35
Col
onia
l Red
SR
I-37
Ret
ro R
ed S
RI-4
2
Met
allic
Silv
er S
RI-6
0
Cha
mpa
gne
SRI-4
8
Antiq
ue P
atin
a SR
I-40
Cop
per P
enny
SR
I-50
Wea
ther
ed Z
inc
SRI-3
9
16 o
z. a
nd 2
0 oz
. Cop
per
*ple
ase
inqu
ire* P
ure
copp
er
has
no w
arra
nty
Rus
teel
Plu
s™ (A
606)
Rus
teel
Plu
s™ h
as n
o m
etal
lic
coat
ing,
is u
npai
nted
and
has
no w
arra
nty
PREMIUM METALLIC COOL KYNAR® COLORS SPECIALIZED MATERIAL
✦ ✦ ✦ ✦ ✦
✦
✦
✦
1,2 1,2 1,22 1,2 1,2 1,2 1,2 1,2
1,22 1,2 1,2 1,2 1,2 1,2 2 2
1,2 1 1 1,2 1,2 1,2
RIVERSIDE CA • SACRAMENTO CA • SALEM OR • SEATTLE WA • WOODINVILLE WA • WWW.TAYLORMETAL.COM
Vint
age®
SR
I-19
Vint
age®
has
a c
olor
rang
e th
at
can
vary
from
bat
ch-to
-bat
ch.
See
TM
P w
ebsi
te fo
r mor
e in
fo
Zinc
alum
e® P
lus
No
finis
h w
arra
nty
– 25
yr.
perfo
ratio
n w
arra
nty
Width Gauge Color LBS SQFT LBS LF14-‐5/8" 24 1 1.36 1.6518" 24 2 1.28 1.9318" 22 1.61 2.42
15-‐3/8" .032 Alum 0.6 0.9
Standard Panels
Mat
te B
lack
SR
I-23
21,2
Gra
phite
Bla
ck S
RI-2
6(fo
rmer
ly: B
lack
)
✦
4
MS-200™Flashing and Details Guide
Taylor Metal Products MS-200TM - UL 90 Floating Clip
18 ga. Base/22 ga. Top
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
UL 580 Class 90 Wind Uplift Rated UL Class A Fire Rated
5
MS-200™Flashing and Details Guide
TAYLORM E T A L P R O D U C T S
Notes to Designer/InstallerTaylor Metal Products is providing the following details as an aid in design. The details in this guide are not inclusive to all design situations. The designer/installer is responsible for modifications and should take into consideration all aspects of the project including climate conditions, such as, snow and wind, as well as, building code requirements, building design, building usage and maintenance requirements.
Installation should be performed only by qualified installers familiar with metal roofing systems and industry standards. For details not shown in this guide, refer to the Sheet Metal and Air Conditioning Contractors National Association (SMACNA) architectural sheet metal manual for proper design. For manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical representative.
The Standard gauge for all products in this guide is 24 gauge and the standard finish is Kynar 500®. We recommend specifying all flashings be the same gauge, color, and finish as the panels to insure long-term durability and color match.
SubstratesDetails in the manual are all shown over solid substrate. MS-200™ can be used over spaced purlins. For solid substrate, Taylor Metal Products recommends 5/8" plywood or metal decking.
UnderlaymentMinimum underlayment requirements are 30 lb. ASTM rated felt, a synthetic underlayment with Class A and ASTM UV protection technology or a high temperature self-adhering rubberized membrane. When choosing the underlayment, consider the roof slope, roof design, roof panel, and the climate.
Drag Load RequirementsAll panels must be pinned at one end to resist the drag load caused by snow loads, live loads, and the weight of the panel. Drag load is a function of roof slope, actual load and length of panels. Contact Taylor Metal Products for specific drag load requirements.
MS-200™ Installation Guide - 2020
MS-200™Flashing and Details Guide
6
TAYLORM E T A L P R O D U C T S
Ventilation/InsulationIt is the responsibility of the designer to determine the material types needed to control condensation and to insulate and ventilate the roof system. Applications over rigid insulation may require blocking for solid attachment and framing the perimeter for installation of perimeter flashings.
Oil CanningFlat metal surfaces will display waviness commonly referred to as “oil canning.” Oil canning is caused by a variety of conditions. Steel mill tolerances, variations in or uneven substrates and roofing underlayments. Oil canning is a characteristic of metal roofing, not a defect and is not a cause for rejection. Taylor Metal Products offers MS-200™ with striations or accent ribs to help minimize oil canning.
Thermal MovementThe Panels and the flashings must be allowed to expand and contract, especially with longer length panels. The panel may need to have a slight gap where the panel hooks the offset cleat to allow for thermal movement of the panels.
Snow DesignThe following details do not address all conditions for snow environments. Consult with the designers, engineers, and others for acceptable details to accommodate your project and climate conditions. When possible gutters, valleys, pitch changes or other penetrations should be minimized in snow areas.
All roof penetrations should be located as close to the ridge or “pin point” top of roof. Snow country requires special designs for valleys to accommodate accumulation of snow and ice from uphill panels. Roof design should be considered in snow areas. Roof design should help resist the melting and freezing of snow and ice.
A fit for purpose roof design has the greatest impact on maintaining a damage free roof system in snow areas. Please contact a Taylor Metal Products representative for assistance in detail designs and appropriate panel selection for specific climate and building conditions.
MS-200™ Installation Guide - 2020
7
TAYLORM E T A L P R O D U C T S
MS-200™Flashing and Details Guide
Handling / Storage & SafetyHandle materials with care when off-loading or moving materials to avoid damage to panels or flashings. Long panels may require two or more pick-up points, properly spaced to avoid damaging panels. Plan ahead; contact Taylor Metal Products for recommendations on handling/hoisting long panels.
Store the panels, flashings and accessories in a dry, well ventilated area, off the ground. If covering, allow ventilation around panels. Elevate one end of bundle to allow drainage of wet materials.
Wear clean, soft-soled shoes when walking on roofing panels to avoid damage to the painted finish.
Take care that sand, gravel, dirt, etc. sticking to your shoes is not carried onto the roof, scratching or otherwise damaging the finish on the roofing material. Walking on asphalt impregnated felt paper, especially on a hot day, can cause the asphalt to stick to your shoes and be tracked on to the roofing material.
Take care when painting to avoid getting over spray on the roofing material. Remember that wind can carry paint particles some distance. Over spray can cause the finish of the roofing material to look dull and may void your warranty.
Secure materials, especially when leaving the site, on the ground or roof to prevent winds from moving the materials. Wind-blown materials may cause damage to the material, property or persons.
Always use proper safety equipment and attire to minimize risk of cuts or other injuries.
Do not walk on panels that have not been completely installed.
Do not walk on major ribs of panels.
Metal roofs that are wet or dusty can be extremely slippery. Wear soft soled shoes and a safety harness to minimize risk of falling.
Avoid installing metal panels in windy conditions.
Safety considerations are the responsibility of the installer and his crew. Be sure to and use common sense generally accepted safety practices when installing roofing materials.
MS-200™ Installation Guide - 2020
8
TAYLORM E T A L P R O D U C T S
Taylor Delivery FleetDelivery FleetTaylor Metal Products prides itself with quick lead times delivered with our fleet of semi trucks. Our fleet of trucks are owned and operated by TMP. All of our drivers are Taylor Metal Products employees, so when your truck rolls in to deliver, you are dealing with Taylor Metal Products. Expect consistant and exceptional service with short leadtimes. The inhouse fleet allows for efficient and cost-effective delivery.
MS-200™ Installation Guide - 2020
Mounted on the rear of our truck's trailer, the trailer-mounted "Piggy-Back" forklift will accompany you right to your place of use, opening up unprecedented possibilities in terms of transportation. It can travel sideways, carrying panels up to 40' long, allowing delivery in locations that would typically be considered impossible to reach.Save time and effort while avoiding potential loading and transport issues; have experienced TMP personnel deliver and unload your order.
9
TAYLORM E T A L P R O D U C T S
Delivery & Will Call/Loading
Will Call & LoadingFlatbed trailers and trucks are best suited to transport metal roofing materials. These can be loaded from the side with a forklift and tied down in a safe and secure manner.
We are not able to load materials onto vehicles and/or trailers which are not suitable or may be hazardous to load. Please be aware that if we find a vehicle to be inappropriate, we reserve the right to refuse to load your order.
Unacceptable examples include: boat trailers, vans, buses, motor homes, campers and box trailers. Pickup racks which do not have sufficient supports for the weight or are not long enough to support bundles are also unacceptable.
Taylor Metal Products is not responsible to tie down loads nor do we provide any tie down materials. Please bring tie downs to secure your load (string or twine are not acceptable for this purpose).
Consider having your order delivered on one of our trucks with a piggy back forklift.
DeliveryWe will make every attempt to deliver material to the desired location. We may be unable to gain access on tight corners or steep terrain. If the site is deemed inaccessible by our driver, the customer may choose an alternate delivery site within a reasonable proximity. If we are unable to make the delivery, additional charges may be assessed.
The customer is responsible for:• Determining adequate access for delivery
ahead of time.• Meeting the delivery at the agreed upon
time.• Providing adequate resources (1-4 people
as needed) for off loading materials.• A charge of $100 per hour may be added
for deliveries that go beyond their allotted time.
• Checking the shipment at the time of delivery.
• Verifying material quantities against the shipping/packing list.
• Noting any damage or discrepancies upon the paper work at the time of delivery and notifying Taylor Metal Products within 48 hours of delivery.
Delivery times are usually scheduled one day in advance. Taylor Metal Products will make every effort to make the delivery at the scheduled time. Please be aware that there may be conditions beyond our control such as traffic, mechanical failures, road closures, etc. which may affect our schedule.
MS-200™ Installation Guide - 2020
Standard Eave
10
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
338"
112"
SPECIFYPITCH
IF PAINTED,THIS SIDE
58" KICK,
12" HEM,
OPEN
#10 SCREW 8" O.C.
UNDERLAYMENTOVER SCREW
DOUBLE ROW OFSEALANT
9" STRIP OFUNDERLAYMENT
STANDARD EAVE
OFFSET CLEAT
SEALANT
MS200 PANEL
FASCIA
SHEATHINGBEND NOTCHED PANELOVER CLEAT. LEAVE SPACE
FOR PANEL EXPANSIONAND CONTRACTION
SEALANT 8"FROM EAVE
SHEATHING
EAVE
9" UNDERLAYMENT STRIP
FASCIA BOARD
MS200 PANEL
UNDERLAYMENT
FIRST CLIP12" FROM EAVE
2" GAPIN SEALANT
SEALANT
SCREW EAVEUNDER PANEL
2- PAN/WAFERHEAD PER CLIP
SEALANT REQUIRED UNDER FLATAS SHOWN IN WET
ENVIRONMENTS ONLY(COASTAL / MARINE AND
WEST CASCADE MTNS)
OFFSET CLEAT
SCREW 8" O.C.
MS200 FlashingsFlashing and Details GuideEave / Hook Eave
STANDARD EAVE DETAIL
STANDARD EAVE(MS200ES)
11
Hook Eave
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
2- PAN/WAFER HEADHEAD PER CLIP
SHEATHING
EAVE
9" UNDERLAYMENT STRIP
FASCIA BOARD
MS200 PANEL
UNDERLAYMENT
FIRST CLIP12" FROM EAVE
2" GAPIN SEALANT
SEALANT
SCREW EAVEUNDER PANEL
SEALANT REQUIRED UNDER FLATAS SHOWN IN WET
ENVIRONMENTS ONLY(COASTAL / MARINE AND
WEST CASCADE MTNS)
SCREW 8" O.C.
438"
1"
112"
58" KICK,
12" HEM,
OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
HOOK EAVE
SCREW
UNDERLAYMENTOVER SCREW
DOUBLE ROW OFSEALANT
9" STRIP OFUNDERLAYMENT
MS200 PANEL
FASCIA
SHEATHINGBEND NOTCHED PANELOVER HOOK. LEAVE SPACE
FOR PANEL EXPANSIONAND CONTRACTION
SEALANT 8"FROM EAVE
HOOK EAVE DETAILHOOK EAVE(MS200EH)
MS200 FlashingsMS200 are 10' FlashingsHook Eave
12
Gutter / Hook Eave
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
SCREW 8" O.C.
LAP UNDERLAYMENTOVER SCREW
DOUBLE ROW OF SEALANT
9" STRIP UNDERLAYMENTUNDER EAVE
HOOK EAVE
GUTTER HANGER
BOXGUTTER
NEOPRENE WASHEREDSCREW.
GUTTER TAPEREDTO DOWNSPOUT
MS200 PANEL
FASCIA
SHEATHING
SEALANT 8"FROM EAVE
5.5"
4"
3.25"1"
1"
.75"
IF PAINTED,THIS SIDE
12" HEM,
OPEN
2X 108°
6"
2- PAN/WAFER HEADSCREWS PER CLIP
SHEATHING
EAVE
9" UNDERLAYMENT STRIP
FASCIA BOARD
MS200 PANEL
UNDERLAYMENT
FIRST CLIP12" FROM EAVE
2" GAPIN SEALANT
SEALANT
SCREW EAVEUNDER PANEL
GUTTER HANGER
BOX GUTTER
SEALANT REQUIRED UNDER FLATAS SHOWN IN WET
ENVIRONMENTS ONLY(COASTAL / MARINE AND
WEST CASCADE MTNS)
1"13
16"
58"
538"
438"
1"
112"
58" KICK,
12" HEM,
OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
HOOK EAVE WITHGUTTER DETAIL
MS200 Flashings
BOX GUTTER(MS200BG)
BOX GUTTER HANGER(AGH6)
Flashing and Details GuideGutter Eave
HOOK EAVE(MS200EH)
13
Standard Ridge
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
4" LAP
4"
1" SEALANT SPACING
MS200PANEL
STANDARD RIDGE
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
INTO EACH END DAMDO NOT FASTEN INTO
STANDING SEAMS
SHEATHING
UNDERLAYMENT
NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE
SEALANT
SCREW END DAMTO SEAM
SPECIFY PITCH
IF PAINTED,THIS SIDE
12 " HEM,
OPEN
7"
STANDARD RIDGE DETAIL
MS200 FlashingsFlashing and Details GuideStandard Ridge
STANDARD RIDGE(MS200RS)
STANDARD RIDGE LAP
14
Vented Ridge
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
3 ROWS OF SEALANT
NEOPRENE WASHEREDSCREW 4" O.C.
1"
4" LAP
SHEATHING
MS200 PANEL
SEALANT
SCREW END DAMTO SEAM
UNDERLAYMENT
VENTED RIDGE
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
TEK SCREW INTOEACH PANEL RIB
4" PERFORATEDSTRIP
NEOPRENEWASHERED
SCREW OR RIVETAT 12" O.C. INTOEACH END DAM.
DO NOT FASTEN RIDGECAP TO STANDING SEAM
SEALANTON TAB
SEALANT
8"
112"
58"
12" HEM,
OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
4X 120°
MS200 FlashingsFlashing and Details GuideStandard Ridge
VENTED RIDGE DETAIL
RIDGE FULL VENTED(MS200RFV)
VENTED RIDGE LAP
15
End Dam Attachment
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
SCREW ENDDAM TO PANEL
SEALANT ON TOP OFRIB TO FILL GAPS
AFTER END DAM IS INSTALLED,FILL ALL VOIDS ON FRONT SIDEOF END DAM WITH GUNNABLE SEALANT.
SEALANT
NEOPRENE WASHERSCREW 1" FROM RIB.4" O.C. MAY BE REQUIREDDEPENDING ON DRAG LOADREQUIREMENTS.
SCREW END DAMTO PANEL RIB
APPLY SEALANT ONBOTTOM AND SIDES
OF END DAM.
SEALANTUP SIDES OF RIB
AND ON TOP.
END DAMEND DAM SEALANT
SHEATHING UNDERLAYMENT MS200 PANEL
SCREW END DAMTO PANEL RIB
SEALANT TO FILL GAPS
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIBAND 4" O.C. MINIMUM, DRAGLOAD CALCULATIONS MAYREQUIRE MORE.
16
Valley FlashingSlope 3:12 or Greater
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
1"11"
SPECIFY PITCH
IF PAINTED,THIS SIDE
1"
.5"11
2"
150° TYP.
THREE ROWS OFSEALANT AT LAP JOINT
6"LAP
1"
FIRST CLIP 12"FROM VALLEY
OFFSET CLEAT
SEALANT
DOUBLE ROW OFSEALANT
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENT
PAN/WAFER HEAD2 PER CLIP
SEALANT 8"FROM EAVE
FASTEN OFFSET CLEAT 8" O.C.SHEATHING
4" MIN.
MS200 FlashingsFlashing and Details GuideValley - 3:12 or Greater
VALLEY 24" FLASHING(MS200VF)
OFFSET CLEAT(MS200OC)
VALLEY 24" DETAIL(3:12 Or Greater Pitch)
VALLEY LAP(3:12 Or Greater Pitch)
17
Valley Flashing - Low Pitch Slope Less than 1/2:12
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
4" MIN
SEALANT
NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.
TRIPLE ROW OF CAULK
UNDERLAYMENT
SEALANT 8"FROM EAVE
SHEATHING
IF PAINTED,THIS SIDE
1"
11"
SPECIFY PITCH
THREE ROWS OFCAULK
12"
MS200 FlashingsFlashing and Details GuideValley Flashing - Recommended Application Less than 3:12 Slope
VALLEY FLASHING( MS200VF)
LOW SLOPE VALLEY DETAIL(Less Than 3 :12 Pitch)
LOW SLOPE VALLEY LAP(Less Than 3 :12 Pitch)
18
Standard Gable
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
134"
438"
134"
58" KICK,
1 " HEM,
IF PAINTED,THIS SIDE1
2"
NEOPRENE WASHERED SCREWOR RIVET 12" O.C.
SCREW WITHSEALANT OVER THE TOP
UNDERLAYMENTDOWN FACE 3" MINIMUM
SEALANT
SUPPORT FLASHINGBEND PANEL 90°
GABLE
SHEATHING
FASCIA21
8"
3"
1"
12"1
2"
18" 151°
UNDERLAYMENT
SHEATHING
FASCIA
SUPPORT FLASHING
SCREWWITH SEALANTOVER THE TOP
MS200PANEL
BEND PANEL 90°
NEOPRENE WASHEREDSCREW OR RIVET
GABLE
SEALANT
GABLE DETAIL GABLE(MS200G)
SUPPORT FLASHING(MS200SF)
MS200 FlashingsFlashing and Details GuideGable
Alternate Gable
19
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
SEALANT
SUPPORT FLASHING
SCREW 8" O.C. WITHSEALANT OVER TOP
CLEAT SCREW
UPEND PANEL AT 90°
ALT. GABLE
SHEATHING
FASCIA
UNDERLAYMENTWRAPPED DOWNFACE 2"
SEALANT
CONTINUOUS CLEAT
ALT. L CLOSURE
212"
438"
58" KICK,
12" HEM,
OPEN
IF PAINTED,THIS SIDE
12"
1"
414"
12" KICK
IF PAINTED,THIS SIDE
218"
3"
1"
12"1
2"
18"151°
1"
134"
12" HEM,
OPEN
IF PAINTED,THIS SIDE
ALTERNATE GABLE DETAIL
ALTERNATE L CLOSURE(MS200ALC)
SUPPORT FLASHING(MS200SF)
ALTERNATE GABLE(MS200AG)
GABLE SUPPORT CLEAT(MS200GC)
MS200 FlashingFlashing and Details GuideAlternate Gable
20
Sidewall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
IF PAINTED,THIS SIDE4.5"
1.75"
12" HEM, 13
4"
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENTTURN UP WALL 8"
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
SCREW WITHSEALANT OVER THE TOP
SUPPORTFLASHING
BEND PANELEDGE AT 90°
SEALANT
WALL PANEL/SIDING
SHEATHING
SIDEWALL
MS200 PANEL
218"
3"
1"
12"1
2"
18"
151°
SHEATHING
WALL PANELLAP UNDERLAYMENTOVER SCREW
SEALANT
SUPPORTFLASHING
MS200 PANEL
SIDEWALL
UNDERLAYMENTTURN UP WALL 8"
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
BEND PANEL 90°
MS200 FlashingsFlashing and Details GuideSidewall
SIDEWALL DETAIL SIDEWALL(MS200SW)
SUPPORT FLASHING(MS200SF)
21
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
Peak Flashing (Ridge End Cap)
4" LAP 1"
4"
LAP 4" WITH 3 ROWSSEALANT
MS200 PANEL
PEAK FLASHINGNEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
INTO EACH END DAM
SHEATHING
UNDERLAYMENT
NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE
SEALANT
538"
7"SPECIFY
PITCH
IF PAINTED,THIS SIDE
1" HEM,OPEN
58" KICK,
12" HEM,
OPEN
1"
514"
12"
SPECIFYPITCH
MS200 FlashingsFlashing and Details GuidePeak Flashing
PEAK FLASHING DETAIL PEAK FLASHING(MS200REC)
PEAK CLEAT(MS200RECC)
PEAK FLASHING LAP
22
Vented Peak Flashing (Ridge End Cap)
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
SHEATHING
MS200PANEL
SEALANT
SCREW END DAMTO SEAM TAB
UNDERLAYMENT
VENTED RIDGE END
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND
4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
TEK INTOEACH PANEL RIB
4" PERFORATEDSTRIP
NEOPRENE WASHEREDSCREW OR RIVET AT 12"
O.C. INTO EACH END DAM.10" - VARIES PER SLOPE
VENTED RIDGE ENDCAP CLEAT
FASCIA
NEO TEK SCREW OR RIVET12" OC INTO END DAM
CLEAT SCREW12" O.C.
SEALANT
514"
12" KICK
IF PAINTED,THIS SIDE
1"
SPECIFYPITCH
6"
10"
58"
112"
IF PAINTED,THIS SIDE
SPECIFYPITCH
12" HEM,
OPEN5
8" KICK,1
2" HEM,OPEN
4" LAP 1"
4"
NEOPRENEWASHERSCREWS
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITHGUNNABLE SEALANT
SEALANTSEALANT ON TOP OFRIB TO FILL GAPS
MS200Flashing and Details GuideVented Ridge EndCap
PEAK FLASHING(MS200SW)
VENTED PEAK FLASHING DETAIL(Vented Ridge End Cap)
PEAK CLEAT(MS200RECC)
VENTED PEAK FLASHING LAP
END DAM DETAIL
23
Pitch Change
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
4" LAP1" GAP
THREE ROWS SEALANT AT LAP JOINT
4"
FASTEN EVERY12" INTO END DAM,AVOID FASTENING INTO STANDING SEAM
TWO ROWS SEALANT
SHEATHING
UNDERLAYMENT, LAPOVER SCREW
MS200 PANEL
PITCH CHANGE FLASHING
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND
4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
FOLD PANEL END 180°,HOOK OVER OFFSET CLEAT
OFFSET CLEAT
FASTEN 8" O.C.
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
12"
1"
12"
112"
MS200 FlashingsFlashing and Details GuidePitch Transition
PITCH CHANGE DETAIL
INSIDE PITCH CHANGE FLASHING
PITCH CHANGE LAP
OFFSET CLEAT(MS200OC)
24
Endwall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
MS200 PANEL
WALL PANEL
5"
6"
IF PAINTED,THIS SIDE
SPECIFY PITCH
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENT
NEOPRENE WASHERED SCREWOR RIVET AT 12" O.C.
WALL PANEL
MS200 PANEL
ENDWALL
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
SHEATHING
MS200 FlashingsFlashing and Details GuideHemmed EndWall
ENDWALL DETAIL
ENDWALL FLASHING(MS200EW)
25
Vented Endwall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
438"
5"
58"
112"
SPECIFYPITCH
2X 135°
IF PAINTED,THIS SIDE
12" HEM,
OPEN
WALLPANEL
TEK SCREWEACH PANEL RIB
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
SEALANT
NEOPRENE WASHEREDSCREW OR RIVET AT 12"
O.C. INTO EACH ENDDAM.
FASTEN 12" O.C.INTO EACH END DAM
4" PERFORATEDSTRIP
UNDERLAYMENT
UNDERLAYMENTOVER SCREW
SHEATHING
3 ROWS OF SEALANTAT LAP JOINT
NEOPRENEWASHERED
SCREW
4" LAP 1"
VENTED ENDWALL DETAIL VENTED ENDWALL FLASHING(MS200EWV)
MS200 FlashingsFlashing and Details GuideVented EndWall
ENDWALL LAP
26
Endwall w/ Saw Cut Reglet
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
SHEATHING
MS200PANEL
UNDERLAYMENT
NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.
SEALANT
TUCK REGLET INTOSAW CUT, SET IN SEALANT
FASTENER24" O.C.
3 ROWS OF SEALANTAT LAP JOINT
NEOPRENEWASHERED
SCREW
4" LAP 1"
4"
5"
6"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1" HEM,OPEN
358"
1"1
2" HEMAT 30°
IF PAINTED,THIS SIDE
12" HEM,
OPEN
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITHGUNNABLE SEALANT
SEALANT
SEALANT ON TOP OFRIB TO FILL GAPS
MS200 - FMFlashing and Details GuideSaw Cut EndWall
ENDWALL LAP
SAW CUT ENDWALL DETAILREGLET
(MS200RF)
ENDWALL(MS200EW)
END DAM DETAIL
27
Back Pan & Soldered Back Pan
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
TAB SIDE WALL TO RECEIVE PAN
TAB AND RIVET BACK PAN
ENSURE END DAM UNDER SIDE WALL IS SEALEDFILL ALL VOIDS WITH SEALANT
HOOK BACK PAN TO OFFSET CLEAT
Z-CLOSURE
TAB SIDE WALL TO RECEIVE PAN
TAB AND RIVET BACK PAN
ENSURE Z-CLOSURE UNDER SIDE WALLIS SEALED, FILL ALL VOIDS WITH SEALANT
HOOK BACK PAN TOOFFSET CLEAT
Z-CLOSURE
1812"
512"
MS200 - FMFlashing and Details GuideBack Pan & Soldered Back Pan
BACK PAN DETAIL
SOLDERED BACK PAN / CRICKET DETAIL
BACK PAN(MS200PAN)
28
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
Curb Sidewall
4"
4"
134"
IF PAINTED,THIS SIDE
12" HEM,
OPEN1"
1"
IF PAINTED,THIS SIDE
178"
WALLPANEL
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENT
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
SEALANT
CURB SIDEWALL
ZEE CLOSURE
NEOPRENE WASHEREDSCREW 8" O.C.
MS200 PANEL
SHEATHING
MS200 - FMFlashing and Details GuideCurb SideWall
CURB SIDEWALL(MS200CSW)
ZEE CLOSURE(MS200ZC)
CURB SIDEWALL DETAIL
29
Curb Endwall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
5"
6"
IF PAINTED,THIS SIDE
1" HEM,OPEN
MS200 PANEL
WALL PANEL
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITHGUNNABLE SEALANT
SEALANTSEALANT ON TOP OFRIB TO FILL GAPS
SCREW END DAMTO SEAM
SHEATHING
MS200PANEL
UNDERLAYMENT
NEOPRENE WASHEREDDRAG LOAD 1" FROMSIDE OF RIB AND4" O.C. MIN. DRAG LOADCALCULATIONSMAY REQUIRE MORE.
NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.
SEALANT
UNDERLAYMENTOVER SCREW
MS200 - FMFlashing and Details GuideCurb End Wall
CURB ENDWALL(MS200CH)
ENDWALL DETAIL
END DAM DETAIL
CURB ENDWALLDETAIL
30
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
Curb / Pan Cricket(Slope 3:12 or Greater)
4" MIN
FIRST CLIP 12"FROM VALLEY
22 GA. OFFSET CLEAT,
SEALANT
DOUBLE ROW OFSEALANT
LAP UNDERLAYMENTOVER SCREW
CURB BACKPAN
CRICKET WHEN CURBIS WIDER THAN 24"
CURB BACK PAN / CRICKET DETAIL(3:12 Pitch or Greater)
4"
FIRST CLIP 12"FROM VALLEY
SEALANT
THREE ROWS OFSEALANT
NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.
UNDERLAYMENT
LAP UNDERLAYMENTOVER SCREW
#14 DEKFAST SCREW2 PER CLIP
CURB BACK PAN / CRICKET DETAIL( Less Than 3:12 Pitch)
MS200 - FMFlashing and Details GuideCurb Pan / Cricket3
12 Slope or Greater
31
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
BEND UP 90°
CUT
REMOVE
BEND DOWN 90°CUT
MS200 PANELSHOWN
Eave to Gable Transition
EAVE TO GABLE TRANSITION
STEP 1
BEND UP 90°
CUT
REMOVE
BEND DOWN 90°CUT
MS200 PANELSHOWN
32
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
TABBED EAVE
UNDERLAYMENT
HOOK EAVE
SUPPORTFLASHING
REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.
FASCIA BOARD,EAVE
FASCIA BOARD,RAKE
1"
PANCAKESCREW
STEP 2
TABBED EAVE
UNDERLAYMENT
HOOK EAVE
SUPPORTFLASHING
REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.
FASCIA BOARD,EAVE
FASCIA BOARD,RAKE
1"
PANCAKESCREW
Eave to Gable Transition
33
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
NOTCH GABLEAROUND EAVE.
SUPPORTFLASHING
GABLE
FOLD PANELAROUNDHOOK EAVE.
CAP GABLEAND SEAL.
PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANELINSIDE CLOSURE.
PLACE FOLD AGAINSTHOOK EAVE FLASHING.
STEP 4
STEP 3
Eave to Gable Transition
NOTCH GABLEAROUND EAVE.
SUPPORTFLASHING
GABLE
FOLD PANELAROUNDHOOK EAVE.
CAP GABLEAND SEAL.
PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANELINSIDE CLOSURE.
PLACE FOLD AGAINSTHOOK EAVE FLASHING.
34
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
SEAL
ROOFPANEL
UNDERLAYMENT
22 GA PLATEFASTENED TO DECK
BOTTOM OF RIVETNOTE: DO NOT PENETRATE PLATE.
SOLID SHANK WATERPROOF RIVET
FOR PIPES LOCATED GREATER THAN 20' FROM PIN POINT
SINGLE 22 GAUGE PLATE TWO OVERLAPPING 22 GAUGE PLATES
SS HOSE CLAMP
SEALANT
Pipe Penetration - on Plate
Allows panel and pipe flashing to move with temperature change.
35Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
BUTYL TAPE
SCREW ZEE CLOSURE4" O.C. MINIMUM
1" TAB WITH FASTENER.FASTEN TO SEAM IF POSSIBLE.SEAL WITH CAULKING.
90° ANGLE TABON EXTERIOR, FASTENED
BUTYL TAPE
CUT HOLE IN PANELAT LEAST 1" LARGERTHAN PIPE
SEAL AROUND PIPE
SEALANT UP SIDESAND TOP OF SEAM
PRE-SEALBETWEEN SEAMS
Pipe Penetration - on Rib
36
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
Pipe Penetration - on Rib
SET HOSE CLAMPAT TOP OF PIPE
BOOT AND SEAL WITHUV RESISTANT SEALANT
NEOPRENE WASHEREDSCREW 11
4" O.C. MINIMUM
PIPE BOOT
BEAD OF SEALANT
SEALANT
CUT HOLE 1"LARGER THAN PIPE
NEOPRENE WASHEREDSCREW 4" O.C. MINIMUM
12" DOWNTURN
ON CAP. ORHEM BACK OVER
ZEE CLOSUREOR FASTEN 4" O.C.
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
37
Pipe Penetration - on PanTAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
SET HOSE CLAMP AT TOPOR USE UV RESISTANT SEALANT
NEOPRENE WASHEREDSCREW 11
4" O.C.
PIPE BOOT
2" MIN
BEAD OF SEALANT
CUT HOLE 1"LARGER THAN PIPE
AND SEAL WITHUNDERLAYMENT
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
38
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
338"
112"
SPECIFYPITCH
IF PAINTED,THIS SIDE
58" KICK,
12" HEM,
OPEN
438"
1"
112"
58" KICK,
12" HEM,
OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
1"
12"
112"
12"
212"
438"
58"
12"
134"
438"
134"
58" KICK,
12" HEM,
OPEN
IF PAINTED,THIS SIDE1
2"12"
34"
1"
1"
314"
4"
512"
12" HEM,
OPEN
1"
12"
134"
12"
414"
1"
218"
3"
1"
12"1
2"
18"
151°
WEIGHT: 4.9 LBS.S.O. 6"SCALE 1:2
( MS200ES )EAVE STANDARD
WEIGHT: 6.5 LBS.S.O. 8"SCALE 1:2
( MS200EH )EAVE HOOK
WEIGHT: 2.5 LBS.S.O. 3"SCALE 1:2
( MS200OC )OFFSET CLEAT
WEIGHT: 13.3 LBS.S.O. 16"SCALE 1:3
( MS200BG )BOX GUTTER
WEIGHT: 7.6 LBS.S.O. 8.5"/9"SCALE 1:3
( MS200G )GABLE
WEIGHT: 7 LBS.S.O. 8.5"SCALE 1:3
( MS200AG )ALTERNATE GABLE
WEIGHT: 2.5 LBS.S.O. 3.25"SCALE 1:2
( MS200ALC )ALTERNATE L CLOSURE
WEIGHT: 4.7 LBS.S.O. 5.75"SCALE 1:3
( MS200GC )GABLE SUPPORT CLEAT
WEIGHT: 6 LBS.S.O. 6.125"/6.625"SCALE 1:3
( MS200SF )SUPPORT FLASHING
MS200 FlashingsMS200 are 10' Flashings
NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED
MS-200™ - FMFlashing and Details SelectionFlashing: 10' Standard
39
TAYLORM E T A L P R O D U C T S
8"
112"
58"
12" HEM,
OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
4X 120°
1"11"
SPECIFY PITCH
IF PAINTED,THIS SIDE
1"
1"
178"
7"
SPECIFY PITCH
IF PAINTED,THIS SIDE
12 " HEM,
OPEN
538"
7"SPECIFY
PITCH
IF PAINTED,THIS SIDE
1" HEM,OPEN
58" KICK,
12" HEM,
OPEN
1"
514"
12"
SPECIFYPITCH
6"
6"
58"
112"
12"
SPECIFY PITCH
IF PAINTED,THIS SIDE
58" KICK,
12" HEM,
OPEN
1614"
1"
SPECIFY PITCH
IF PAINTED,THIS SIDE
WEIGHT: 17.4 LBS.S.O. 21.25"SCALE 1:6
( MS200RFV )RIDGE FULL VENTED
SCALE 1:6 S.O. 24" WEIGHT: 19.7 LBS.
VALLEY FLASHING( MS200VF )
SCALE 1:3 S.O. 3.875" WEIGHT: 4.7 LBS.
ZEE CLOSURE( MS200ZF )
WEIGHT: 13.1 LBS.S.O. 15"SCALE 1:4
( MS200RS )STANDARD RIDGE
WEIGHT: 11.9 LBS.S.O. 14.5"SCALE 1:4
( MS200REC )PEAK FLASHING
WEIGHT: 6 LBS.S.O. 6.75"SCALE 1:3
( MS200RECC )PEAK CLEAT
WEIGHT: 12.9 LBS.S.O. 15.75"SCALE 1:4
( MS200RECV )VENTED PEAK FLASHING
MS200 FlashingsMS200 are 10' Flashings
VALLEY WIDE FLASHING( MS200FW )
SCALE 1:5
S.O. 34.5"
WEIGHT: 28.2 LBS.
MS-200™ Installation Guide - 2020
MS-200™ - FMFlashing and Details Selection
Flashing: 10' Standard
MS-200™ - FMFlashing and Details SelectionFlashing: 10' Standard
40
TAYLORM E T A L P R O D U C T S
5"
6"
12"
4"
4"
12"11
2"1
2"
134"
414"
134"
12"
358"
1"
12"
5"
6"
12"
SPECIFY PITCH
12"
112"
58"
5"
438"
SPECIFY PITCH
1812"
512"
SPECIFY PITCH
SCALE 1:4 S.O. 11.5" WEIGHT: 9.8 LBS.
CURB ENDWALL( MS200CH )
SCALE 1:3 S.O. 5.625" WEIGHT: 4.6 LBS.
REGLET( MS200RF )
CURB SIDEWALL( MS200CSW )
SCALE 1:4 S.O. 10" WEIGHT: 8.2 LBS.
SIDEWALL( MS200SW )
SCALE 1:4 S.O. 8.75" WEIGHT: 10.3 LBS.
WEIGHT: 9.8 LBS.S.O. 11.5"SCALE 1:4
( MS200EW )ENDWALL
WEIGHT: 10.7 LBS.S.O. 12"SCALE 1:4
( MS200EWV )VENTED ENDWALL
MS200 FlashingsMS200 are 10' Flashings
WEIGHT: 21.3 LBS.
S.O. 24"
SCALE 1:4
( MS200PAN )BACK PAN
MS-200™ Installation Guide - 2020
MS-200™ - FMFlashing and Details Selection
Flashing: 10' Standard
41
TAYLORM E T A L P R O D U C T S
4"
6"
1"
12"
12"
WEIGHT: VARIES
S.O. VARIES
END DAM
MS200 FlashingsMS200 are 10' Flashings
WEIGHT: 3.3 LBS.S.O. 4"SCALE 1:3
( MS200PS )PERFORATED STRIP
NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED
GUTTER HANGER( AGH6 )
SCALE 1:2
S.O. 8"
WEIGHT: 6.5 LBS.
MS-200™ Installation Guide - 2020
Panels with * need Pattern Choice:□Ribs □Striations □Flat Notched? Y / N Clip Relief? Y / N Sealant? Y / N
Job Name: Ship To: □ Will Call Day:
Order Form □ New Order □ Add-on Order □ Quote
Inside Sale:
PO #: Date:
□ Delivery Delivery Date:
PBRMarion “R” Panel2-1/2" CorrugatedClassic 7/8" CorrugatedGR-7HR-34T-3Tuff-Rib
□□□□□□□□
12" Easy-Lock*16" Easy-Lock*16" StreamLine*12" CL-175*
□□ □□ □ □□□□
Color: Pitch: Gauge: Dmatch: Pallet: 10' 20' 30'
Panel & Flashing Items
Quantity Length Item Description Part # Quantity Length Item Description Part #
4566 Ridge Dr NE • Salem, OR 97301 • F: 503-581-6877 • P: 503-581-8338 • www.taylormetal.com
Forgetting Anything? Underlayment? Screws? Clips? Caulking? Closures?
TAYLORM E T A L P R O D U C T S
Sold To: Order Contact:Phone #:Fax #:
□ Agricultural □ Residential □ Commerical Route:
□□□
ShadowLine**(circle): 1", or 1-1/2" 1/2" to 3" Reveal:
1"x12-5/8" SmoothWall**1"x12-5/8" Lifetime Soffit**
Panels with ** need Pattern Choice: □Striations □Flat □1 V-Groove □2 V-GroovesPerforated?
12-3/8" Slim-Lock*16-1/4" Slim-Lock*12" MS-200*14-5/8" MS-200*16" MS-200*18" MS-200*12-3/4" MS-150*16-5/8" MS-150*20" MS-150*13-3/4" MS-100*17-5/8" MS-100*
□□□□□□□□□ □ □
12" Versa-Span*14-5/8" Versa-Span*16" Versa-Span*18" Versa-Span*15-1/2" T-Panel*
*All Kynar Slim-Lock, Easy-Lock, Lifetime Soffit, SmoothWall, ShadowLine, T-Panel, Versa-Span, CL-175, MS-100, MS-150, & MS-200 flashings are 10'*All ArmorTech StreamLine, T-3, Tuff Rib, GR7, PBR, HR-32, Marion "R", & Corrugated flashings are 12'6"
Flat not available on StreamLine
(Available on Lifetime Soffit Only)
( )Standard Panels are in Bold font.
Custom Trim OrderTAYLORM E T A L P R O D U C T S
Please provide a drawing for each flashing with precise measurements and anglesFax to: 503-581-6877
4566 Ridge Dr NE Salem OR 97301 • Phone: 503-581-8338 or 1-800-574-1388 • www.taylormetal.com
Custom Trim OrderTAYLORM E T A L P R O D U C T S
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Please provide a drawing for each flashing with precise measurements and angles
www.taylormetal.com
Customer Name: Job Name:
Gauge: Color:
TAYLORM E T A L P R O D U C T S
QUALITY PRODUCTSEXCEPTIONAL SERVICE
SALEM BRANCH4566 Ridge Dr. NESalem, OR 97301
Office: 503-581-8338Toll Free: 1-800-574-1388
Fax: 503-581-6877
WOODINVILLE BRANCH5927 234th St. SE
Woodinville, WA 98072
Office: 425-485-3003Toll Free: 855-334-8558
Fax: 425-485-2710
SACRAMENTO BRANCH5711 Perrin Ave
McClellan, CA 95652
Office: 916-318-8844Toll Free: 1-800-574-1388
Fax: 916-993-4123
AUBURN BRANCH710 A. St. NW Suite 101
Auburn, WA 98001
Office: 206-900-9923Toll Free: 1-800-574-1388
Fax: 253-804-3545
RIVERSIDE BRANCH4880 Felspar St.
Riverside, CA 92509
Office: 323-407-7457Toll Free: 1-877-504-1594
MS-200™ Installation Guide • ©2020 Taylor Metal Products
Revised 11/20
Recommended