Mechatronic flow sensor for high Fluid sensors and ...Measurement of liquids up to 180 C. Process...

Preview:

Citation preview

Measurement of liquidsup to 180 °C.

Process cooling in an induction furnace.

Mechatronic flow sensorThe flow sensor works to the principle of spring-support-ed piston: the piston, located in the valve seat in thehousing, is lifted by the flowing medium against thespring resistance. The piston position is monitored via amagnetic-field sensor and is output as an analogue signal.The spring resistance forces the piston to return to itsoriginal position with decreasing flow. This ensures posi-tion-independent installation of the flow sensor preven-ting backflow.Due to the temperature decoupling of the transducerfrom the electronics, this sensor is especially suitable formedia in high temperature applications of up to 180 °C.The units are maintenance-free.

product news

For flow ranges of 0.3...25 l/min.

Analogue output signal 4...20 mA.

Simple and robust.

Fast response time ≤ 10ms.

Pressure ranges up to 15 bar.

Mechatronic flow sensor for hightemperatures.

Flu

id s

enso

rs a

nd

dia

gn

ost

ic s

yste

ms

bus,identification

and control systems

fluid sensors and diagnostic

systems

position sensors

and objectrecognition

3e Str. SBT 12.qxd 15.03.2012 10:48 Uhr Seite 2

Common technical data

Operating voltage [V] 24 DC (-15 % / + 10 %)

Short-circuit protection •

Materials in contactwith the medium

stainless steel 304/1.4301;nickel-plated brass;

PPS;O-ring: FPM

Ambient temperature [°C] 0...60

Response time [s] < 0.01

Current consumption [mA] < 30

Reverse polarity / overload protection • / •

TypeSBT, SBM

Dimensions

3565

M12x1

M12x1

1376,5

13

Rp

43

Rp

43

L+

L

1

3

2

Wiring

SBT633

Processconnection

Mediumtemperature

[°C]

Accuracy

[% of the final value]

Pressureresistance

[bar]

Orderno.

Connection cable 0.3 m with M12 connector · analogue function mode 4...20 mA

Rp 3/4 20...180 ± 5 15 SBT633

Protection rating,protection class

IP 67, III

G 3/4 20...180

Measuring range

[l/min]

0.3...25

0.3...25 ± 5 15 SBM613*IP 67, III

Applications:Liquids (water, glycol solutions).

* Only measuring insert for OEM solutions, no replacement part.35

65

M12x1

M12x1

20

4070

47157

30

G 43

SBM613

43

2 1

Thermographicdiagramof an SBT typeflow sensor.

Flu

id s

enso

rs a

nd

dia

gn

ost

ic s

yste

ms

Flow sensors

For further technical data please go to: www.ifm.com

ifm a

rtic

le n

o. 7

5114

68 ·

Prin

ted

in G

erm

any

on n

on-c

hlor

ine

pape

r. ·

We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

· 04

.201

2

3e Str. SBT 12.qxd 15.03.2012 10:48 Uhr Seite 3

Recommended