MANN Filters for Liquids
2Industrial Filters Business Unit Filter solutions for many industrial applicationsThe customers of the Industrial Filters BusinessUnit include companies from nearly every areaof industry. Our aim is to offer comprehensiveafter-sales service to our customers within eachsector and therefore the business unit is dividedinto four business areas, each with its own team:
Mechanical engineering and production tech-nology
Industrial engines, construction equipmentand agricultural machinery
Pneumatics and vacuum technology Representatives
In each team sales engineers and technicianswork closely together to meet your specificrequirements.
And it is very easy to find the right contactperson:If you dont have a contact person yet atMANN+HUMMEL or with one of our representa-tives please phone
+49 (62 32) 53 80
and tell us your industrial application. We willimmediately put you through to your salesengineer.
The wide range of products manufactured byMANN+HUMMEL include products and servicesfor a variety of industrial applications.In order to be flexible and serve our customersindividually the MANN+HUMMEL group is divi-ded into two divisions the automotive techno-logy division and the industrial technology divi-sion organised in eight business units.
The business units of the automotive technologydivision: Air Filter Systems Intake Manifolds Systems Liquid Filter Systems Cabin Filters Filters
The business units of the industrial technologydivision: Industrial Filters ProTec Hydromation
We know our customers needs and speak their language
3Content
Product overview Page 4
MANN Spin-on filters Page 7
MANN Fuel filters Page 13
MANN Filter elements Page 19
MANN In-line filters Page 25
MANN Suction filters Page 39
MANN Filters for two-way ventilation Page 43
Conversion factors Page 47
4Matching filters ...
Spin-on filters
Filter elements
In-line filters
Suction filters
Filters for two-way ventilation
... for every fluid
5
Page 7Page 13
Page 19
Page 25
Page 39
Page 43
For the filtration of fuels, lube and hydraulic oils Application: motors, gears, general machinery
For the filtration of fuels, lube and hydraulic oils, coolants and paints
Application: motors, gears, general machinery
For the filtration of fuels, lube oils and hydraulic fluids
Application: motors, machines, plants, automotive hydraulics
For the filtration of lube and hydraulic oils Application: hydraulic systems, gears
For aeration and ventilation Application: gears, tanks for liquids
6
7MANN micro-Top Spin-on filtersfor lube and hydraulic oils
Bac
kgro
und
pic
ture
: D
eutz
AG
8MANN micro-Top Spin-on filters
MANN Spin-on filters are fine filters used for the filtration of lube and hydraulic oils as well as inengines, machines and installations.The fineness of the MANN micro-Top filter ele-ments (star-pleated paper) is in the m range.
Design
The MANN micro-Top filter element is fixed intothe housing. The inlet and outlet for the liquid to be filtered are located in the threaded cover. The spin-on filters are simply screwed on specially provided connections on enginesand machines.
Operation
Spin-on filters are generally used as full-flow fil-ters, i.e. they are installed in the circuit in a wayensuring that all the liquid to be cleaned passesthrough them every time it circulates.
Deposit of dirt particles on the paper elementcauses the flow resistance to increase.
When a certain differential pressure is rea-ched (e.g. upon cold start or when the fil-tering element is clogged), a bypassvalve in the filter opens, ensuring suffi-cient lubrication.For the opening pressure of the bypassvalve, please see the relevant table.
An optionally integrated non-returne valveprevents the running dry of the filter. In this
way the operating pressure is reached quicklyafter starting the engine.
9Filter fineness: 12 m 50 % fractional separation efficiency(single pass)30 m 99 % fractional separation efficiency(single pass)Other filter fineness upon request
Nominal flow rate: 25 to 540 l/min.Operating pressure: 14; 20; 25 or 35 bar (1.4; 2; 2.5 or 3.5 MPa)Operating temperature: Max. 120 CBypass valve: Opens at differential pressures of 0.8 to 2.5 /
3.5 bar with or without non-return valve
Technical data
MANN micro-Top Spin-on filters
Maintenance
Usually, the maintenance frequency is determi-ned by the engine or machine manufacturer.The maintenance work to be performed is limi-ted to the replacement of the complete spin-onfilter. The removal tool shown on page 12 helpsin loosening the filter.On the Spin-on filters suitable for pressures upto 14 bar (1.4 MPa), an integrated non-returnvalve prevents oil to flow out during the servicing.
Configuration
The stated values in the table are standardwhich depending on the application can beadjusted upwards. For further information plea-se ask your sales engineer.
Bypass valve Housing Cover
MANN micro-Top filter element Non-return valve Seal
10
MANN micro-Top Spin-on filtersNominal pressure 14 bar (1.4 MPa)
Spin-on filters for this pressure range are usedprimarily for the filtration of lube oils.Applications for other liquids upon request.
Opening pressure of bypass: 0.8 to 2.5 bar(80 to 250 kPa).
With non-return valve.
Filter mounting: metric thread
Filter mounting: unified thread in inches
Part No.
W 712/15W 815W 920/25
Nominalflow rate
[l/min]
1520 20
d1
M 18x1.5M 20x1.5M 20x1.5
Form
DDB
Bypass valve
[bar] [KPa]
1.0 1001.5 1500.8 80
d2
626262
d3
717171
h
948995
d4
809096
d5
768693
Non-returnvalve
[bar] [KPa]
0.12 120.12 120.12 12
Dimensions in mm and inches
Part No.
W 712/1W 712/4W 719/4W 920W 920/7W 930W 940W 940/1W 940/13W 940/18W 950W 950/1W 962W 962/2W 1130W 1140W 1170W 11 102W 1374/2W 1374/4
Nominalflow rate
[l/min]
1215202525254040404045457070304570
1008585
d1
3/4 16 UNF3/4 16 UNF3/4 16 UNF3/4 16 UNF3/4 16 UNF3/4 16 UNF3/4 16 UNF3/4 16 UNF3/4 16 UNF1 12 UNF1 12 UNF1 12 UNF1 12 UNF1 12 UNF
3/4 16 UNF3/4 16 UNF1 12 UNF
11/8 16 UNG 11/411/2 16 UN 2 B
Short desi-gnationto DIN
ISO 71457
A 0.4
B 0.5
B 0.6B 0.8
A 0.8x1A 1
A 1.2B 1.2
Form
CCCABAABFBBBBACCCCEE
Bypass valve
[bar] [KPa]
2.5 2502.5 2502.5 2501.2 1202.5 2502.5 2501.2 1202.5 2502.5 2502.5 2501.2 1202.5 2502.5 2501.0 1001.2 1201.2 1202.5 250
d2
626262626262626262626262626262626293
100100
d3
7171717171717171717171717171717171
104111111
h
7993
1239595
114142142142142170170210210115135227260177177
d4
8080809696969696969696969696
110110110110140140
d5
7676769393939393939393939393
108108108108136136
Non-returnvalve
[bar] [KPa]
0.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 120.12 12
Dimensions in mm and inches
d1
h
d5
d4d3d2
7
SW 30
Form F
Form E
Form D
Form C
Form B
Form A
11
MANN micro-Top Spin-on filtersNominal pressure 35/25/20 bar (3.5/2.5/2.0 MPa)
Spin-on filters for this pressure range are usedprimarily for the filtration of hydraulic oils incompliance with DIN 51 524 and DIN 51 525.Applications for other liquids upon request.
Opening pressure of bypass: 0.8 to 2.5 bar(80 to 350 KPa).
Filter mounting: unified thread in inches
Part No.
WD 724/3WD 920WD 940WD 940/2WD 950WD 950/2WD 962WD 1374WD 13 145
Nominalflow rate1)
[l/min]
2025403540507095
180
d1
3/4 16 UNF3/4 16 UNF3/4 16 UNF1 12 UNF1 12 UNF1 12 UNF1 12 UNF
11/2 16 UN11/2 16 UN
Form
EEEEEEEEE
Maximumoperatingpressure
[bar] [MPa]
35 3.525 2.525 2.525 2.525 2.525 2.525 2.5
20 2.0
d2
626262626262.562
100100
d3
717171717172.571
111111
h
14097
144144172170212177302
d4
80969696969896
140140
d5
76939393939693
136136
Bypass valve
[bar] [KPa]
3.5 3502.5 2502.5 2502.5 2502.5 2503.5 3502.5 250
2.5 250
Dimensions in mm and inches
d1
d2
d4d3
d5
h
Form E
Bypass valve
Flow resistance 0.3-0.6 at 36 mm2/sec.1)
12
Accessories for MANN micro-Top Spin-on filters
Double union
When the mounting plate is provided with afemale thread, a double union is required for theassembly of the filter.
Removal tool
For easy disassembly of the MANN micro-TopSpin-on filters.
Dimensions and part numbers
Part No.
21 018 15 33121 019 15 11121 025 15 10121 030 15 25121 039 15 101
d3
1213182230
d1
M 18x1,53/4 16 UNF1 12 UNF
11/8 16 UN11/2 16 UN
d2
M 18x1.5M 18x1.5M 24x1.5M 30x1.5M 38x1.5
Dimensions in mm and inches
a
10171717.519.5
b
1014.515.517.515
h
2535.5374041
SW
2424273246
Form A (see page 10) with loosening cam only requires a heavy screwdriver or a round bar, 8 to 10 mm thick, for disassembly.Form E (see page 10 and 11) requires the strap-type tool commercially available.
Mann micro-Top Spin-on Filters
Filter formSuiting MANN removal tool
CLS 7
W 7 ...
DLS 7/2
W 8 ...
DLS 8
W 9 ...
BLS 9
W 11 ...
CLS 11
LS 7LS 9LS 11
LS 8
LS 7/2
SW
a b
h
d2d3d1
Form DForm DForm BForm C
13
MANN Fuel filtersB
ackg
roun
d p
ictu
re:
Deu
tz A
G
MANN Fuel filters
MANN Fuel filters are fine filters used for the eli-mination of wearing and noxious particles fromdiesel and gasoline.
Injection pumps and nozzles of diesel engi-nes, injection systems of gasoline injec-tion systems and carburettor installationsare protected from impurities and wearmost efficiently when equipped with theappropriate and ideally specified MANNfuel filter.
MANN+HUMMEL supplies spin-on filtersboth with or without water trap and drainas well as filters for in-line installation.
Spin-on filters are screwed on a matchingconnection on engines or on a separate filterhead. Small-sized units can be installed in fle-xible pipes without extra fastening.
14
MANN Fuel filtersfor distributor pumps of diesel engines
Small to medium-sized diesel engines, such asthose found in agricultural and commercialvehicles, are commonly equipped with distribu-tor-type fuel-injection pumps.
MANN Fuel filters for distributor pumps and sole-noid-controlled injection systems are always pro-vided with water traps and draining devices. The usual filter solution in this case is the spin-onfilter with a fineness between 2-6 m.
The actual filter element of the spin-on filter isfixed in the metal housing. The central connetion thread serving as output for the clea-ned fuel is located in the filter cover, near theintake openings and the filter seal. Usually, 4intake openings are arranged concentrically bet-ween the central connection and the filter seal.
Part No.
WK 842WK 842/2WK 842/6
Filter fineness
[m]
4 62 3
60 (prefilter)
Nominalflow rate
[l/h]
808080
d1
M 16x1.5M 16x1.5M 16x1.5
d2
616161
d3
707070
d4
84.584.584.5
d5
818181
h
133133133
Maximumoperating pressure[bar] [MPa]
6 0.66 0.66 0.6
Dimensions in mm and inches
d1
h
38
d5
d2
d3
d4
15
Water draining device
22.5
16
MANN Fuel filtersfor in-line pumps of diesel engines
In-line pumps are utilised mainly in medium andlarge-size diesel engines for commercial vehicles.
For this type of pump, MANN+HUMMEL recom-mends fuel filters without water draining device.The average filter fineness ranges between 8 to10 m.
The design of these filters is comparable to thatof the spin-on filters equipped with water draina-ge, as used on injection installations with distri-butor pumps (see page 15).
Part No.
WK 712/2WK 731WK 731/1WK 712/3WK 723WK 940/5WK 962/4
Nominal flow rate
[l/h]
120120120120120120200
d1
M 16x1.5M 16x1.5M 16x1.5M 16x1.5M 16x1.5M 16x1.5M 16x1.5
d2
62623062626262
d3
71713871717171
d4
80808080809696
d5
76767676769393
h
80117115
80124142210
Maximumoperating pressure[bar] [MPa]
6 0.66 0.62.5 0.259.5 0.959.5 0.956 0.62.5 0.25
Dimensions in mm and inches
d1
d5
h
d2
d3
d4
17
MANN Fuel filtersfor installation in flexible lines
Specially designed filters are available for instal-lation in hoses and flexible lines.
Small filters made of transparent synthetic mate-rial can be used in carburettor engines, as wellas for the filtration of diesel fuel and heating oil,provided the filter fineness requirements are lessdemanding. They allow relatively high flow ratesthough their size is moderate.
Larger in-line filters with metal housing and filtermedia meeting high standards of fineness can be supplied upon request (used for example toprotect injection aggregates on gasoline andinjection engines).
Part No.
WK 21WK 21/2WK 31/2WK 31/4WK 31/51)
WK 32WK 43/1
for installation in lines
d1 d2
6mm6mm6 and 8mm8mm8mm1)
6 and 8mm8mm
Dimensions in mm
right-angled output socket
d
h
d1
1)
d
h
d2
d1d1
dh
Fig. 1 Fig. 2 Fig. 3
Fig.
1122223
d
21213537373759
Mesh width orfilter paper
50 m136 mFilter paper element200 m200 mFilter paper elementFilter paper element
h
5050
104104105142108
18
19
MANN micro-Top Filter Elementsfor filters for liquids
Bac
kgro
und
pic
ture
: A
rbur
g
hd2d1
d2d1
h h
d2d1
h
d2d1
d2
h
d1
20
MANN micro-Top Filter Elements
MANN micro-Top filter elements are fine filtersfor engine and hydraulic oils, fuels, coolantsand paints. The filter fineness is in the m range.
The MANN micro-Top filter elements are distin-guished by following features:
High and constant filtration efficiency High dirt-retention capacity of the paper filter
elements due to the large filtering surfaceand the optimal paper structure.
The specially embossed paper ensures lasting efficiency of the whole filter surfaceover the entire operating time.
Resistance to water, coolants, fuels,oils and other hydrocarbons up to temperatu-res of 140 C thanks to the special impregnation.
Various types as per DIN- or ISO-speci-fications.
Available in more than 100 countries.
Operation
The flow of liquid to be filtered passes the filterfrom the outside to the inside. Exception:Filter elements for steering hydraulic systems.
Types
Maintenance
The maintenance frequency is usually prescri-bed by the engine or installation manufacturer.Servicing is limited to the replacement of theMANN micro-Top filter elements.
Form A Form B Form C Form D Form E
21
Dimensions in mmNominal flowrate[l/h]
35153730904)
654)
9570
1204)
8072
1101201503104)
Short designationas per DIN 73 358
DIN 73 358 E 0.5DIN 73 358 E 0.2
DIN 73 358 E 1
DIN 73 358 E 2
Form(Page
20)
BAAB5)
D5)
D5)
AAD5)
AB5)
AB5)
B6)
D
h
133445368
11665
100,584
14789
100125118167171,5
d21)
8,5121483)
142)
142)
1421142)
33262126103)
202)
d1
4052655165656570837277728383
106
Part No.
MANN micro-Top Filter Elementsfor fuel filters and partial-flow oil filters
MANN micro-Top Filter elements and MANN felt filter elements for fuel filters
Interchangeable in filters to DIN 73 358, 73 359 and 73 360. For this reason, the dimensions indicated are those of the largest element.Seal diameter for pipes to DIN 2391 or similar bolt.Nominal diameter for bolt.Flow rate with 1 m gradient (when new, to DIN 73 358).With felt gasket.With cork insert.
MANN micro-Top Filter elements (fiber pack) for oil filters in partial flow
Part No.
PF 815PF 915PF 925PF 1025PF 1155PF 1190PF 13 140PF 1535PF 1552PF 19 326
Filling volume[cm3]
310520630
1 300950
1 6002 3003 8005 500
10 100
Short designationas per DIN 71 455
DIN 71 455 E 1
DIN 71 455 E 1.5DIN 71 455 E 2.5DIN 71 455 E 3.5DIN 71 455 E 5DIN 71 455 E 8
Form(Page 20)
DDDDDDDDDD
h
104110110206125202202250367378
d1
75909898
110110130150150197.5
d21)
14141414141414253222
Dimensions in mm
Seal diameter for pipes to DIN 2391 or similar bolt.
MANN micro-Topfilter elements
P 46/1P 64P 78P 609P 7071)
P 7151)
P 725P 810P 8111)
P 824P 825P 833P 921/2P 934P 1018/11)
MANN Felt filterelement
BF 7071)
BF 7151)
BF 8111)
BF 1018/11)
1)
2)
3)
4)
5)
6)
1)
22
MANN micro-Top Filter ElementsStar-pleated paper elements for full-flow oil filters
MANN micro-Top Filter elements for full-flow oil filters
Part No.
H 53H 53/31)
H 601H 6179)
H 712H 715/1H 720H 729H 804H 813/1H 815H 816H 820/3H 827/1H 829H 928/1H 932/2H 943H 943/2H 947/1H 960H 973H 1018/2H 1029/1H 1032H 1034H 1038H 1048H 1050/1H 1050/2H 1053H 1053/2H 1060H 1072H 1072/11H 1075/1H 1081H 1258H 1263/1H 1290/1H 14651)
H 1496H 1565/1H 10 196H 12 105H 12 107H 12 107/1H 12 110/1
Nominal flow rate
[l/min]
55
12162313192222111518202528303046534757722232273)
4035505750613)
496882827282636075638568
195100958188
Short designationas per DIN ISO 7747
A 70x26x117A 70x26x165
A 100x30x117
A 100x30x165
A 100x30x196A 100x30x234
A 100x40x234
Form(Page 20)
AAAAB5)
BAAB7)
B5)
CB6)
ABAAAAB6)
DAD4)
B7)
B6)
CAB5)
B7)
ABCB5)
AAB5)
BAABBAB5)
B7)
AB5)
AAB
h
6464
100.5100.5156.510911716514087.5
107.5108.5117154165117134196201196229220.278
101126117119.5151165182204179.5196234236.5262234165138165163229106.5565232196196227.5
d1
4040595970707070697276727272728784849084849094
100100100
94100100
99100
92100100100
92100117117118132133150100114117117117
d2
12.812.81828.2332026263332192)
322133262024.224.23223.424.224.43434192)
3034263030252)
49303040.550407356599588884036565656
Dimensions in mm
23
MANN micro-Top Filter Elementsfor full-flow oil filters and filters for steering hydraulic systems
MANN micro-Top Filter elements for filters for steering hydraulic systems
Part No.
H 601/4H 615H 910/2H 919/7
Nominal flow rate
[l/min]
13139
25
Form(Page 20)
ACC2)
C
h
100.5111.560.5
111.5
d1
60598282
d2
18131)
131)
131)
Dimensions in mm
Seal diameter for pipes to DIN 2391 or similar bolt.Without grip.
MANN micro-Top Filter elements for full-flow oil filters (continued)
Part No.
H 12 113H 12 178H 12 225H 12 270H 13 127/18)
H 15 111/2H 15 134H 15 134/1H 15 135H 15 190H 15 190/6H 15 190/11H 15 222/2H 15 2631)
H 15 395H 15 432H 15 475H 15 490H 15 490/2H 18 265H 18 300H 20 211H 20 440H 25 669
Nominal flow rate
[l/min]
11113218322210498
14314380808080
20026239235580
525525227303175363663
Short designationas per DIN ISO 7747
A 152x88x196
Form(Page 20)
AB6)
BBAAAB7)
CCCCABBBCABAABBA
h
229336462559210.5165196211252364364364330425631597364722733363484183366366
d1
117117117117128150150150150150150150150150150150150150150170170194194242
d2
4355565614.588888831.531.5313188888888318888
115115118118132
Dimensions in mm
Flow from the inside to the outside. With felt gasket.Seal diameter for pipes to DIN 2391 or similar bolt. With cork gasket.Flow rate related to discharge cross section. See project drawing.Without clip. With bypass valve.With cardboard end cap as gasket.
1)
2)
3)
4)
5)
6)
7)
8)
9)
1)
2)
24
25
MANN In-line filtersB
ackg
roun
d p
ictu
re:
Men
gele
26
MANN In-line filters ...
Design
The filters consist of a filter head with twothreads, mounting holes and a MANN micro-TopSpin-on filter
Versions available:
with bypass valve, without service indicator
with bypass valve and service indicator
with bypass valve and service switch(make /break contact, convertible)
Service indicators or switches and bypass valvesare combined to signal the need for filter service before the bypass valve opens.
Operation
MANN In-line filters are mainly used as full-flowfilters. All the liquid to be cleaned passes throughevery time it circulates. The filters can also beused for return flow.Deposit of dirt particles on the paper elementcauses the flow resistance to increase. When acertain differential pressure has been reached(e.g. upon cold start or when the filter element isclogged), a bypass valve in the filter opens,ensuring sufficient and constant lubrication.
R
P
R
P
R
P
MANN In-line Filters are fine filters used mainlyin hydraulic systems for the filtration of motorand gearbox oils and in lube-oil circuits in thegeneral machine construction. The fineness of the MANN micro-Top filter elements (star-pleated paper) is in the m range.
27
Tankentlftungs-filter
Saugfilter
Leitungsfilter
Leitungsfilter
Tank
Frder-pumpe
Hochdruck-pumpe
Hochdruckfilter
Filter fineness: 12 m 50 % fractional separation efficiency(single pass)30 m 99 % fractional separation efficiency(single pass)Other filter fineness upon request
Nominal flow rate: 25 to 540 l/min Operating pressure: 14; 20; 25 or 35 bar (1.4; 2; 2.5 or 3.5 MPa)
For non-automotive applications, observe the regulations on the construction of pressure vessels
Operating temperature: Max. 120 C Material: Filter head made of cast aluminiumBypass valve: Opens at differential pressures of 2.5 or 3.5 bar
(250 or 350 KPa) with our without non-return valveService indicator: Indication through red signal ring at a differential
pressure of 1.8 bar (180 KPa)Service switch: Switching at differential pressure of 1.8 bar (180 KPa)
Electrical connections see page 37/38
Technical data
Assembly and maintenance
The filters are installed in pipelines (refer todimension table for threads). Attention must bepaid to the flow direction, indicated on thethreads by arrows. Maintenance is limited to thereplacement of the clogged spin-on can: A service indicator or switch signals that a servi-ce is necessary. The MANN removal tool on page12 helps in loosening the filter.
... for full and return flow
MANN In-line filters in hydraulic circuits
High-pres-sure pump
High-pressure filter
In-line filter
Filter for tankventilation
In-linefilter
Tank
Feedpump
Suction filter
28
MANN In-line filtersNominal pressure 14 bar (1.4 MPa)
Characteristics
Flow resistance as per ISO 3968 at 36 mm2/sec.
Part No.
67 502 62 02667 503 62 02667 502 62 10667 504 62 126
Nominal flow rate[l/min]1)
25402540
Spin-on filter
W 920W 940W 920W 940
Dimensions in mm and inches
d1 h
M 20x1.5 145M 20x1.5 192
G 1/2 145G 1/2 192
Weightapprox.
[kg]
0.720.830.720.81
95
h
17
93
11
R 12
5512
5832
d1
d1
1053 50 100 300
67 5
03 ..
... /
67
504
.. ...
67 5
06 ..
...
67 5
12 ..
... /
67
612
.. ...
67 6
25 ..
...
67 5
02 ..
...
Flow rate values are only valid for liquids with 36 mm2/sec and flow resistance according to the above diagram.1)
Volume flow (l/min)
Diff
eren
tial p
ress
ure
p (b
ar) 1.0
0.5
0.1
0.05
29
h
147147147
194194194
269269269
Part No.
67 502 62 25667 502 62 23667 502 62 226
67 503 62 30667 503 62 27667 503 62 266
67 506 62 70667 506 62 66667 506 62 676
Spin-on filter
W 920W 920W 920
W 940W 940W 940
W 962/2W 962/2W 962/2
Weightapprox.
[kg]
1.21.21.3
1.21.21.3
1.61.61.7
Fig.
123
123
123
Serviceindication
optical
electrical
optical
electrical
optical
electrical
a
909090
909090
959595
b
404040
404040
47,547,547,5
c
21.521.5
21.521.5
28.528.5
c1
2424
2424
2626
h1
222222
222222
252525
e
M 8,16
deep
M 8,16
deep
M 10, 20
deep
d1
a
h1
h2
h
7
93
b
ec1
c53
38 c1
cb
e
d11)
G 1/2G 1/2G 1/2
G 1/2G 1/2G 1/2
G 1G 1G 1
Dimensions in mm and inches
Nominal flow rate: 40 l/min2)
Nominal flow rate: 40 l/min1)
Nominal flow rate: 70 l/min2)
b
e
Fig. 1 Fig. 2 Fig. 3
h2
4662
4662
4662
Other threads upon request.Flow rate values are only valid for liquids with 36 mm2/sec and flow resistance according to the diagram on page 28.
1)
2)
Service indicator
removal clearance 30
Service switchswivels by 360
30
MANN In-line filtersNominal pressure 14 bar (1.4 MPa)
Part No.
67 512 62 10667 512 62 13667 512 62 12667 625 62 1061)
67 625 62 1161)
67 625 62 1261)
Nom.flowrate
[l/min]3)
120120120180180180
Spin-on filter
2x W 962/22x W 962/22x W 962/2 2x W 11 102 2x W 11 1022x W 11 102
Weightapprox.
[kg]
2.82.84.24.64.84.7
Fig.
123123
Serviceindication
optical
electrical
opticalelectrical
a
200200200270270270
b
4040
4545
c
47,54343706565
d12)
G 1G 1G 1
G 11/2G 11/2G 11/2
h1
303030353535
d2
939393
108108108
h
275275275337337337
c1
47.547.5
7070
Dimensions in mm and inches
356
50
108
G 11/4 G 11/4
h2
130
43
28 28
130
43
28 28
130
d1h1
h2
h
7
d1
d2
a
c
a
c c1
b b
a
c c1
b b
Part No.
67 612 62 14667 612 62 17667 612 62 166
Nominal flow rate[l/min]1)
100100100
Spin-on filter
W 11 102W 11 102W 11 102
Weight approx.
[kg]
4.14.25.2
Fig.
123
Serviceindication
optical
electrical
h2[mm]
4662
Fig. 2 Fig. 3
Fig. 1
Fig. 1 Fig. 2 Fig. 3
h2
4662
4662
Filters supplied without release cam. Other threads upon request.Flow rate values are only valid for liquids with 36 mm2/sec and flow resistance according to the diagram on page 28.
1)
2)
3)
Flow rate values are only valid for liquids with 36 mm2/sec and flow resistance according to the diagram on page 28.1)
Service indicator
removal clearance 30
Service switchswivels by 360
M 10, 20 deep M 10, 20 deep
47.5 47.5
M 10, 20 deep
47.5
Service switchswivels by 360
Service switchswivels by 360
M 10, 20 deep
M 10, 20 deepM 10, 20 deep
removal clearance 30
31
MANN In-line filtersNominal pressure 35/25/20 bar (3.5/2.5/2.0 MPa)
Characteristics
Flow resistance as per ISO 3968 at 36 mm2/sec.
d2
h1
h2
d1
a
h
b
e
b
ec1
c53
38 c1
cb
e
1053 20 50 100 200 500
67 4
03 6
2 ...
/ 67
504
62
... (W
D 9
40)
67 5
04 6
2 ...
(WD
940
/2)
67 5
12 6
2 ...
67
708
62
...67
716
62
...
67 7
30 6
3 ...
/ 67
730
62
...
67 7
50 6
2 ...
67 5
06 6
2 ...
67 5
02 6
2 ...
Fig. 1 Fig. 2 Fig. 3
Part No.
67 403 62 246
67 502 62 24667 502 62 21667 502 62 20667 504 62 43667 504 62 45667 504 62 44667 504 62 42667 504 62 41667 504 62 40667 506 62 75667 506 62 69667 506 62 65667 506 62 646
67 708 62 1462)
67 708 62 1562)
67 708 62 1662)
67 716 62 21667 716 62 22667 716 62 236
Spin-on filter
WD 724/3
WD 920WD 920WD 920WD 940WD 940WD 940WD 940/2WD 940/2WD 940/2WD 962WD 962WD 962WD 962
WD 1374WD 1374WD 1374WD 13 145WD 13 145WD 13 145
Weightapprox.
[kg]
0.9
0.730.830.831.31.41.40.870.970.972.72.72.82.8
3.03.13.13.43.53.5
Fig.
1
1231231231123
123123
a
90
90909090909095959595959595
135135135135135135
b
40
40404040404047.547.547.547.547.547.547.5
565656565656
c
21.521.5
21.521.5
28.528.5
28.528.5
3030
3030
c1
2424
2424
2626
2626
2626
2626
d11)
G 1/2
G 1/2G 1/2G 1/2G 1/2G 1/2G 1/2G 1G 1G 1G 3/4G1G1G1
G 11/4G 11/4G 11/4G 11/4G 11/4G 11/4
h1
22
22222222222225252525252525
282828282828
d2
76
93939393939393939393939393
136136136136136136
h
192
149149149196196196203203203271271271271
246246246371371371
Dimensions in mm and inches Nominalflow rate[l/min]3)
20
25252540404035353570707070
959595
180180180
Serviceindication
opticalelectric.
opticalelectric.
opticalelectric.
opticalelectric.
opticalelectric.
opticalelectric.
Operating pressure 25 bar (2.5 MPa)
Operating pressure 35 bar (3.5 MPa)
Operating pressure 20 bar (2.0 MPa)
e
M 8
, 16
dee
pM
10,
20
dee
p
h2
4662
4662
4662
4662
4662
4662
Other threads upon request.Without bypass valve.Flow rate values are only valid for liquids with 36 mm2/sec and flow resistance according to the above diagram.
1)
2)
3)
removal clearance 30
Service indicator
Service switchswivels by 360
Volume flow (l/min)
Diff
eren
tial p
ress
ure
p (b
ar) 1.0
0.5
0.2
0.1
0.05
32
MANN In-line filtersNominal pressure 25/20 bar (2.5/2.0 MPa)
Part No.
67 512 62 15667 512 62 16667 512 62 17667 730 63 12667 730 63 11667 730 63 10667 730 62 29667 730 62 26667 730 62 256
Nominal flow rate[l/min]3)
120120120360360360360360360
Spin-on filter
2 x WD 9622 x WD 9622 x WD 9622 x WD 13 1452 x WD 13 1452 x WD 13 1452 x WD 13 1452 x WD 13 1452 x WD 13 145
Weightapprox.
[kg]
4.14.24.26.86.96.96.86.96.9
Fig.
1.11.21.2222222
Serviceindication
optical
electrical
opticalelectrical
optical
electrical
a
200200200320320320320320320
d12)
G 1G 1G 1
SAE1)
SAE1)
SAE1)
G 2G 2G 2
h1
303030424242424242
d2
939393
136136136136136136
h
277277277402402402402402402
Operatingpressure
[bar] [MPa]
25 2.525 2.525 2.520 220 220 220 220 220 2
Dimensions in mm and inches
d1h1
h
62
d1
d2
53
a
d2
a
102 d1
h
h1d1 102
X
40 40
43
2535
160
53
60
62
80
102
Fig. 1 Fig. 2
Fig. 1.1
Fig. 1.2
Available upon request: 1 counterflange (with 4 screws and 4 spring washers), Part No. 22 078 21 101.Other threads upon request.Flow rate values are only valid for liquids with 36 mm2/sec and flow resistance according to the diagram on page 31.
1)
2)
3)
View X
removal clearance 30
Service switchswivels by 360
M 10, 20 deep
removal clearance approx. 30
Service switchswivels by 360
M 12, 26 deep
M 12, 26 deep
42.9
77.7550.8
47.5
47.5
M 10, 20 deep
Service switchswivels by 360
33
Part No.
67 750 62 10667 750 62 11667 750 62 126
Nominal flow rate[l/min]1)
540540540
Spin-on filter
3 x WD 13 1453 x WD 13 1453 x WD 13 145
Weightapprox.
[kg]
10.210.210.2
Fig.
111
Serviceindication
optical
electrical
a
480480480
d1
SAESAESAE
h1
53.553.553.5
d2
136136136
h
424.5424.5424.5
Operatingpressure
[bar] [MPa]
20 220 220 2
Dimensions in mm
d1
d2
d1h1
53a
h
X
160 160
40
95
80 160
110
116
Fig. 1
Flow rate values are only valid for liquids with 36 mm2/sec and flow resistance according to the diagram on page 31.1)
Service switchswivels by 360
removal clearance 30
55.5
View X
M 12, 26 deep
50.8
88.963.5M 12, 26 deep
Connector for Service indicatorand Service switch
47.5
Part No.
67 506 82 1763)
67 506 82 16667 506 82 13667 612 82 11667 612 82 146
Nominal flow rate2)
[l/min]
808080
100100
Spin-on filter
2 x WD 9622 x WD 9622 x WD 9622 x W 11 1021)
2 x W 11 1021)
Weightapprox.
[kg]
4.34.44.47.37.3
Fig.
11122
Serviceindication
optical
electrical
electrical
d1
939393
108108
d2
102102102130130
h2
5050507171
h
294294294373373
h1
2222225353
Operatingpressure
[bar] [MPa]
25 2.525 2.525 2.510 110 1
With non-return valve.The flow rates indicated apply to liquids with a viscosity of 36 mm2/sec. (cSt) given a flow resistance of 0.4 to 0.6 bar (40 to 60 KPa). Nominal flow rate of a filter half.Selector lever SW 24, Part No. 02 086 01 024.
Dimensions in mm
34
MANN In-line filters, selectable duplexNominal pressure 25/20/10 bar (2.5/2.0/1.0 MPa)
Switching filter halves allows maintenance ofthe filter without turning off the unit.
Characteristics
Flow resistance as per ISO 3968 at 36 mm2/sec.
10 20 50 100 200
67 5
06 8
2 ...
67 6
12 8
2 ...
67 7
30 8
2 ...
h1h27
38 160
A
h d1
d2
100
70
53
62
27
81
1111
31
54
G 1
153
32
194
80
27
44
200
200
3035
53
62
G 11/2
Fig. 1 Fig. 2
1)
2)
3)
Volume flow (l/min)
Diff
eren
tial p
ress
ure
p (b
ar) 1.0
0.5
0.2
0.1
0.05
removal clearance 30
Service switchswivels by 360
26.5M 12, 25 deep
35
Available upon request: 1 counterflange (with 4 screws and 4 spring washers), Part No 22 078 21 101.The flow rates indicated apply to liquids with a viscosity of 36 mm2/sec. (cSt) given a flow resistance of 0.4 to 0.6 bar (40 to 60 KPa). Nominal flow rate of a filter half.
Part No.
67 730 82 1061)
67 730 82 1261)
67 730 82 1161)
Nominal flow rate2)
[l/min]
180180180
Spin-on filter
2 x WD 13 1452 x WD 13 1452 x WD 13 145
Weightapprox.
[kg]
9.79.89.8
Fig.
112
Serviceindication
optical
electrical
d1
136136136
d2
160160160
h2
707070
h
424424424
h1
525252
Operatingpressure
[bar] [MPa]
20 220 220 2
Dimensions in mm
A
d1
h1
h
h2
200
53
38
d2
ZUR REINIGUNG DREHEN
18
35
103
91
M 12
92
25
160
292
18
35
103
107
M 12
92
25
160
292
Fig. 1 Fig. 2
1)
2)
removal clearance 30
42.9
Serviceswitchswivels by360
50.5
42.9
50.5
77.8 77.8
36
MANN Service indicatorsFor In-line and high-pressure filters
MANN Service indicators signal that the filter ele-ment is clogged and needs servicing. A red sig-nal appears in the display window. Permissibleoperating temperature: 120 C.
Part No.
59 020 79 20259 020 79 21259 020 79 315
Switching pressure
[bar] [KPa]
1.8 1801.8 1805 500
d
M 18x1.5M 10x1M 24x2
h
221619
h1
36
44.5
h2
464444
Operatingpressure
[bar] [MPa]
25 2.525 2.5
400 40
Dimensions in mm
h1
h2
h
d
Clean liquids
Dirty liquids
37
MANN Service indicatorsFor In-line and high-pressure filters
When the time has come for service, the sole-noid switch activates a signal device (e.g. pilotlamp or buzzer) or a switch-off device.
Operating temperature: max. 120 C
Switch type: make/break contact Breaking voltage: max. 220 V Rupturing capacity: max. 12 W/18 VA Inrush current: max. 0.8 A Protection: IP 65 protective insulation
Part No.
59 010 79 20259 010 79 30559 010 79 3151)
59 010 79 405
Switching pressure
[bar] [KPa]
1.8 1805 5005 5005 500
d
M 18x1.5M 24x2M 24x2M 18x1.5
h
221919
7.5
h1
3659.544.544.5
h2
62.56161
62.5
Operatingpressure
[bar] [MPa]
25 2.5400 40400 40220 17.5
With opening pressure for bypass valve of 7 0.9 bar.
Dimensions in mm
h
h2
h1
d
X
53
38
1)
Clean liquids
Dirty liquids
Movable through 4positions 90 apart
View X
movable continuouslythrough 360
Connection for wirewith diameter of 4.5to 7 mm
38
Service switchesFor In-line and high-pressure filters
Recommendations for electrical installationof service switches
Each service switch is equipped with a high-quality relay (reed contact). In order to ensuretrouble-free operation, observe the following:
1. We recommend using a low voltage neon-glow bulb or LED for electric/optical display. Both can be switched on and off directly without spark arrestors.
2. Incandescent bulbs require a very high switch-on current compared to their opera-ting current. Therefore, select the bulb and a series resistor in such a way that the switchs maximum rating (refer to plaque on unit) is not exceeded when it is turned on. Werecommend selecting the series resistor in such a way that the current reaching the switch is still under the switchs peak switch-on current level before counting the incan-descent bulb. That protects it completely against overload; it does mean, however, thatthe bulb receives only undervoltage.
3. By switching inductive loads, current peaks may be induced that might destroy the service switch. Therefore, if using alternating current, install an RC combination parallel to the relay or protection coil; if using DC, install a recovery diode (such as a 1 N 4007 diode) parallel to the inductivity in the reverse direction.
By dimensioning the sparkarresting devices,observe any guidelines issued by the manufac-turer of the protection coil or relay.
In neither case is it permissible to exceed theswitchs maximum rating (refer to plaque onunit).
~
UB
UBIF
LED
+
-
RV ~~
~
~
+
-
glow bulb
Specify RV such that IF = approx. 15 to 20 mA
resistor
incandescent bulb
capacitator
resistor inductiveresistance
recovery diode
39
MANN Suction filtersB
ackg
roun
d p
ictu
re:
Deu
tz F
ahr
Agr
arte
chni
k
40
Tankentlftungs-filter
Saug-filter
Niederdruckfilter
Tank
Frder-pumpe
Hochdruck-pumpe
Hochdruckfilter
MANN Suction filters ...
Assembly and maintenance
The in-line suction filters are installed in pipeli-nes (see dimension table for threads). The main-tenance is limited to the replacement of theclogged filter. The necessity of servicing can beindicated by means of a pressure measuringdevice or service switch.
MANN Suction filters are used primarily in hydraulic circuits.
Design and operation
The filters consist of a filter head with twothreads, mounting holes and a MANN micro-Top spin-on filter.
Technical data
Filter fineness: 12 m 50% fractional separation efficiency(single pass)30 m 99% fractional separation efficiency(single pass)Other filter fineness upon request
Nominal flow rate: 60 l/minVersion with bypass valve availableOperating pressure: -0.8 bar (-80 KPa)Operating temperature: max. 120 CMaterial: Filter head made of cast aluminiumService indicator: Indication range: -1/+0.6 barService switch: Switching at a differential pressure
of -0.5 0.2 bar (-50 20 KPa) Breaking voltage max. 42 V =~
Inrush current: 1 ARupturing capacity: max. 12 WSwitch type: make contact
MANN Filters in hydraulic circuits
High-pressurepump
High-pressure filter
Low-pressure filter
Filter for tankventilation
Tank
Feedpump
Suctionfilter
In-linefilter
41
Characteristics
Flow resistance as per ISO 3968 at 36 mm2/sec.
20 30 40 50 60 70 100 200
67 70
8 62 .
..
... for in-line installation
Part No.Complete filter
67 708 62 18667 708 62 20667 708 62 26667 708 62 27667 708 62 286
Nominal flow rate
[l/min]
6060606060
Spin-onfilter
W 1374/2W 1374/2W 1374/2W 1374/41)
W 1374/41)
Serviceindicator
optical
electrical
optical
c
3030
30
h
246336330246336
c1
2626
26
Dimensions in mm
136
X
28
177
h
G 11/4
c
c1
56
135
Spin-on filter with bypass valve, opening pressure 0.2 + 0.15 bar (20 + 15 KPa).Other threads upon request.
1)
removal clearance 20
Volume flow (l/min)
Diff
eren
tial p
ress
ure
p (b
ar) 0.2
0.1
0.05
0.04
0.02
0.03
0.01
View X
M 10, 20 deep
42
MANN Suction filtersStar-pleated strainer design
MANN Star-pleated strainer filters are used primarily for suction operation in hydraulictanks.
Assembly and maintenance
The filter is screwed directly onto the suctionsocket of the feed pump or a similar suc-tion pipe. The filter maintenance is carriedout latest when an oil change becomesnecessary.
Technical data
Filter fineness: 100 m(other fineness upon request)
Strainer web: Phospor bronze
d2
SW
d1
h2h1
Part No.
62 300 53 55162 300 53 57162 300 53 54162 500 53 41162 501 53 28162 501 53 29162 602 53 25162 602 53 261
Nominalflow rate[l/min]1)
203030456080
120150
Filteringsurface[cm2]
170310310460650900
1 4001 800
Weightapprox.
[kg]
0.150.200.250.500.700.751.101.20
d1
616161878787
110110
d2
G 1/2G 1/2G 3/4G 1G 1G 1G 11/2G 11/2
SW
2727364141416060
h1
55848785
105155165205
h2
427170.563.584
134120160
Flow rates apply to liquids with a viscosity of 36 mm2/sec. (cSt) at a flow resistance < 0.1 bar (10 KPa).
Dimensions in mm and inches
Tankentlftungs-filter
Saugfilter
Niederdruckfilter
Tank
Frder-pumpe
Hochdruck-pumpe
Hochdruckfilter
MANN Filters in hydraulic circuits
High-pressurepump
High-pressure filter
Low-pressure filter
Filter for tankventilation
Tank
Feedpump
Suction filter
1)
In-linefilter
43
MANN Filters for two-way ventilation in hydraulic systems
Bac
kgro
und
pic
ture
: Li
nde
44
MANN Pico air filters ...
Maintenance
Fig. 1, 2 and 4 (Page 45): On maintenance, thecomplete filter is replaced by a new one.
Fig. 3 (Page 45): The MANN micro-Top filter element is replaced after the hood has beenremoved.
MANN Pico air filters are single-stage air filtersused mainly for the two-way ventilation of liquid tanks.
Design
The filtration is ensured by a MANN micro-Topfilter element. The MANN Pico air filter canbe supplied with integrated pressure controlvalve (see fig. 4 on page 45). Provided that the configuration is correct, air exchange in the tank will be almost completely avoided and aircarrying oil will not escape.
Assembly
The filters must be installed in an area of thetank where the dust level is low. To ensure perfect operation, position them vertically ( 15 variation). Fasten them with a clampingsocket, plug or bayonet type cap, flanged orthreaded connection.
Characteristics
30
20
10
3
4
5
6
7
89
45 0
03 6
5 90
0
45 0
09 7
2 14
6
45 0
09 7
7 10
6
45 0
03 6
2 90
2
45 0
01 6
2 18
5
45 0
01 6
2 15
5
30
20
10
3
4
5
6
7
89
1 2 4 6 8 50402010
45 0
37 7
7 01
5
45 3
75 7
7 10
4
45 2
40 7
7 10
4
45 1
38 7
7 12
6
45 0
32 7
7 10
5
45 0
21 7
7 12
5
45 0
74 7
7 11
5
Flow
res
ista
nce
p (m
bar
)
Flow
res
ista
nce
p (m
bar
)
Volume flow (l/min)0 0.06 0.08 0.1 0.2 0.4 0.6 0.8 1 1.2
Volume flow (l/min)
45
... for hydraulic systems
Part No.
45 001 62 15545 001 62 18545 003 65 90045 003 62 90245 009 72 14645 009 77 10645 021 77 12545 032 77 10545 037 77 01545 074 77 11545 138 77 12645 240 77 10445 375 77 104
Nominalflow rate[m3/min]
0.50.52.03.54.58.0
15.023.032.0
RespectiveMANN micro-Top
filter element
-1)
-1)
-1)
-1)
C 75/4C 75/4C 1112C 1132C 1337C 1574C 21 138/1C 26 240C 30 375
Fig.
1122333333333
Weightapprox.
[kg]
0.050.080.060.080.30.30.50.651.11.37.09.0
11.0
d1
M 14x1.5M 18x1.5
35G 3/4M 26x1.5
2040526080
100140180
d2
454580809898
132132170208283318396
h
47476573.5
110110120152175185200302285
Dimensions in mm and inches
On maintenance, the complete filter is replaced by a new one.
MANN Pico air filters with pressure control valve
Part No.
45 003 62 90045 003 62 901
Openingpressure
[bar] [KPa]
0.85 850.35 35
Weightapprox.
[kg]
0.10.1
Nominal flow rate[m3/min]
0.20.2
On maintenance, the complete filter is replaced by a new one.
80
G 3/4
Fig. 4
d1
d2
h
d1
d2
hh
d1
d2
1)
Fig. 1 Fig. 3Fig. 2
73.5
46
MANN Filters for two-way ventilation are usedin liquid tanks for pressure compensation.
Design
Vent filter and intake strainer are combined. Thefilter element is either a foam insert, star-foldedpaper or oil-wetted steel net.
Assembly and maintenance
The filters must be installed in an area of thetank where the dust level is low. They may befastened by a clamping socket, plug or bayonettype cap, flanged or threaded connection. Theycan be cleaned when they become noticeablydirty.
Filters for two-way ventilation with intake strainer
Part No.
41 004 62 14241 004 62 23243 010 62 10043 010 63 1002)
Nominalflow rate[m3/min1)]
0.40.40.70.7
Fig.
1123
Weightapprox.
[kg]
0.250.250.40.4
d1
M 33x1.5G 1 BG 271.5
d2
76767777
h
78786454
Dimensions in mm and inches
t
100958896
Given a flow resistance of p = 10 mbar (1 KPa).6 self-tapping screws (for holes of 4.5 mm diameter) to fasten the filter and a seal are included as standard.
28
d1
d2
h
t
70d1
51
d2
h
t
d2
d1
82
49
h
t
M 5
1)
2)
Fig. 1 Fig. 3Fig. 2
47
Length
1 m = 1000 mm = 39.38 inch = 3.281 ft.1 inch = 25.4 mm = 0.0254 m = 0.08333 ft.1 ft. = 304.8 mm = 0.3048 m = 12 inch
Volume
1 m3 = 1000 litres = 35.31 ft.3 = 61020 inch3
1 ft.3 = 28.32 litres = 0.02832 m3 = 1728 inch3
1 litre = 0.2642 US gallon = 0.2201 Engl. gallon1 US gallon = 3.785 litres = 231 inch3
1 Engl. gallon = 4.544 litres = 277 inch3
Weight
1 kg = 2.205 lb = 35.27 Oz1 lb = 0.4536 kg = 16 Oz1 Oz = 0.02835 kg = 0.0625 lb
Pressure
1 bar = 100 KPa = 14,5 psi = 401.5 IN. H2O10 mbar = 1 KPa = 0.145 psi = 4.015 IN. H2O10 psi = 68.95 KPa = 0.6895 bar = 27.68 IN. H2O1 IN. H2O = 0.2491 KPa = 2.491 mbar = 0.03613 psi
Conversion factors
Temperature
F = (C x 9/5) + 32C = (F 32) x 5/9
Power
HP = KW x 1.341KW = HP x 0.746
Flow rates
1 litre/min = 0.0353 cfm1 m3/min = 35.3140 cfm1 m3/h = 0.5886 cfm1 Engl. gallon/min = 0.1605 cfm
The MANN+HUMMEL Group
The MANN+HUMMEL groupoperates worldwide with 9100employees at 38 company locations around the world.The company develops,produces and distributes highly developed automotivecomponents such as air cleaner systems and intakesystems, liquid filter systemsand cabin filters as well as filter elements for the servi-cing and repair of vehicles.Products manufactured alsoinclude industrial filters, filtersystems and material handlingdevices for use in the fields of mechanical engineering,process technology and industrial production.MANN+HUMMEL customersoperate in many fields with theemphasis on series produc-tion in the automobile industry.
Air Filter Systems Business Unit
Intake Manifold SystemsBusiness Unit
Liquid Filter Systems Business Unit
Air filters and air cleanersystems
Air conduction (unfiltered andfiltered air, supercharger lines)
Components, e.g. mufflers,conrol cabinets, heating pipes,control valves, design covers
Crankcase ventilation systems
Intake manifold modules andsystems, components for spinand tumble control
Engine components, e.g. fuelsupply rails, secondary turbo-chargers, cylinder head covers
Liquid containers for brakingand steering oils, windscreenwasher systems, headlightcleaning systems
Complex plastic parts
Liquid filter systems in plasticand metal
Components, e.g. oil pumps,integrated oil-water heatexchangers
Oil pans, valves Oil centrifuges in metal and
plastic
Automotive OEM Division
Filters Business Unit
Industrial Filters Business Unit
Filter elements for air andliquids
Cabin filters for particle filtrationand gas absorption, combinati-on filters
Air-drying boxes Cooling-water filters Spin-on oil filters and fuel
filters Elements for oil-aerosol sepa-
rators
Air and liquid filters for indu-strial engines, construction andagricultural machinery, com-pressors
Air-oil separators for compres-sed air systems
Process filters for mechanicalengineering and process tech-nology
Cabin filters
Filter elements and Systems for Industry and Trade Division
ProTec Business Unit
Hydromation Business Unit
Systems and equipment formaterial handling and materialsprocessing in the plastic, rub-ber, recycling and chemicalindustries
Systems and equipment for thefiltration of machining liquids inmechanical production
Chip handling systems andchip transport systems
Industrial Systems and Components Division
MANN+HUMMEL GMBHIndustrial Filters Business UnitD-67323 SpeyerTelephone 0049 (0) 6232 53-80, Fax 0049 (0) 6232 53-88 99E-mail: if.info@mann-hummel.com, Internet: www.mann-hummel.com
19 9
42 1
0 10
1 en
040
3 P
rinte
d in
Ger
man
y
Recommended