Low voltage switchboard for electrical distribution
NORMABLOC
Motor Control Center up to 6000 A
PARS TABLEAU
[ ] MCC Motor Control Center
Your installations evolve,our solutions tooIn a constantly changing industrial and economic world,
you need to be able to upgrade your installations at all
times to remain competitive.
Only electrical installations made up of modular
switchboards are able to meet the challenges you face.
with normabloc, you are completely free to add new
feeders to your motors.
Simply modular and open-
endedThe modularity of the normabloc functional
switchboards means.
you can modify or upgrade them with ease to adapt to
your changing processes and thus increase
performance. The withdrawable drawers let you make
these upgrades while the equipment is energised,
without cutting switchboard supply and in a completely
safe environment.
The switchboard is designed with free slots to add
new functions or extra motor feeders, even at the last
minute.
or extra motor feeders, even at the last minute.
2
With , you are completely free to add new feeders to NORMABLOCyour motors
MCC
PARS TABLEAU
3
[ ] MCC Motor Control Center
Low Voltage Withdrawable
Switchboard Rear access to
Connection
High electrodynamic withstand capacity and
suppression of the arc tracking risk.Supplying bars immerse inside a cast block of resin
and silica.
Fully withdrawable equipment.Equipments isolation and unlocking are obtained by a
removable crank handle for circuit breakers on cradle,
and by a handle for drawer type equipments.
Easy transformation for drawer - type
equipments. Change of module by simple removing of
slides and partition plates, the switchboards remaining
alive.
Maximum installation facility.Large rear volume for cables connection.
Distribution and motor control centerModular design withdrawable equipments up to 6000
Amps.
The N 660 low voltage switchboards answer all the
needs of repartition and distribution of energy set in large
industries. Equipments enable them to be adapted to the
most various installations complying in the same time
with the most strict way to the following requirements:
operation facilities
personal safety
flexible design
reduced dimension
most of the protection function, circuit-breaker or
contactor, are withdrawable, therefore easy to
disconnect and to interchange. The relaying or interlock
and control devices are regrouped on a fixed or draw-out
type independent panel, enabling, without breaking the
power circuits, a possible control or intervention.
PARS TABLEAU
[ ] MCC Motor Control Center
PART OF REFERENCESPROJECT NAME END USER CLIENT
TABRIZ PETROCHEMICAL CO.
NEIRIZ CEMENT PLANT PROJECT
KHOUZESTAN CEMENT PLANT
GACHSARAN GAS INJECTION PROJECT
KHARG METHANOL PROJECT
SOUTH PARS PHASE
WATER TREATMENT PROJECT
HORMOZGAN CEMENT PROJECT
NGL PROJECT
RAMSHIR GAS INJECTION PROJECT
AZADEGAN PROJECT
NGL900
SOUTH
PARS,PHASE 20 - 21
SOUTH
PARS,PHASE 17 - 18
MONTAZER GHAEM POWER UNIT1,2,3
AHWAZ-RAY PUMPING STATION
REQ.EGP-44230-TR
CENTRAL TERMINAL
SOUTH PARS PROJECT (PHASES II,III)
GOLE GOHAR PROJECT
KAROUN III POWER PLANT
AHWAZ BANGESTANI WELLS
FAJR PETROCHIMICAL PROJECT
CZ/C3 RECOVERY
BINAK PROJECT
KHARG PETROCHIMICAL PROJECT
MOBIN PETROCHIMICAL PROJECT
RIO PROJECT
FARS COMBINED CYCLE POWER PLANT
MOBIN PETROCHIMICAL PROJECT
AHWAZ-RAY PUMPING STATION
AZARBAIJAN PIPE LINE PROJECT
3 COMPRESSOR STATIONS KHUZESTAN
SOUTH PARS PHASE 9 & 10
JAM SHEET PLANT
GENAVEH POWER PLANT
TABRIZ PETROCHEMICAL CO.
NEIRIZ CEMENT CO .
KHOUZESTAN CEMENT CO .
NATIONAL IRANIAN OIL CO.
KHARK PETROCHEMICAL CO.
NIOC
KHOUZESTAN CEMENT CO.
HORMOZGAN CEMENT PLANT
NATIONAL IRANIAN OIL CO.
NATIONAL IRANIAN OIL CO.
PEDEC.
NISOC
POGC
POGC
IRAN ELECRICITY DEVELOPMENT ORGANISATION
PIPE AND TELECOME LINES
KALA NAFT CO .
IMAM KHOMEINI INTERNATIONAL AIRPORTY
PARS OIL AND GAS
GOLE GOHAR CO .
IPDC
SOUTH OIL FIELDS CO.
FAJR PETROCHIMICAL CO.
PARS PETROCHIMCAL CO.
SOUTH OIL REGIONS
KHARG PETROCHIMICAL CO.
MOBIN PETROCHIMICAL CO.
SAIPA CO.
IPDC
MOBIN PETROCHIMICAL CO.
OD & CC CO .
NATIONAL IRANIAN OIL CO.
NATIONAL IRANIAN OIL CO.
PARS OIL & GAZ CO .
FOOLAD SAZAN JAM CO.
MAPNA
TABRIZ PETROCHEMICAL CO.
TABRIZ CEMENT CO .
EHDAS CONTROL CO .
DRY ZONE PRODUCT MANAGEMENT
KHERAD & NOVIN CO.
PETROPARS
KHOUZESTAN CEMENT CO.
EHDAS CONTROL CO
SAZEH CO .
NARGAN CO .
RAMPCO
PIDECO
IOEC
IPMI
MAPNA CO .
O.C PIPE AND TELECOME LINES
KALA NAFT CO .
TABIRAN CO .
NPCC VIA ALSTOM
NAMVARAN CO .
FARAB CO .
TABIRAN CO.
ESPEK CO .
NARGAN CO .
TARH & PALAESH CO .
KHARG PETROCHIMICAL CO.
SPEC CO .
SAIPA CO.
MAPNA
KHERAD SANAT CO .
OD & CC CO .
ARIA PETRO GAZ CO .
SETIRAN CO .
LG & OIEC CO .
FOOLAD SAZAN JAM CO.
MECO.
4
PARS TABLEAU
MOBARAKEH STEEL PLANT MOBARAKEH STEEL PLANT COMPLEX IRITEC CO.
DAMAVAND B.O.P POWER PLANT MAPNA SAFANICU CO.
BARDSIR STEEL PLANT BARDSIR STEEL PLANT TAM IRAN KHODRO
RAZI PETROCHEMICAL GLASS PLANT RAZI RAZI
General characteristics
Description
Applications
Refrence standards
Installation
Mechanical characteristics
Cable entry
Access
Protection Index (IP)
Segregation
height
width
depth
Casing coating
Frame
Casing colorElectrical characteristics
Rated insulation voltage (Ui)
Rated service voltage (Ue)
Rated frequency (F)
Rated impulse withstand voltage (Uim
p)
Rated auxiliary circuit voltage
overvoltage category
Pollution index
Rated current (In)
Horizontal busbar rating
Vertical busbar rating
PolesHorizontal busbars
Rated short time withstand current (Icw) 1s
Rated peak withstand current
Vertical busbars
Rated short time withstand current (Icw) 1s
Rated peak current
Rated peak withstand current
Internal arcing personal protection IEC 61641
Earthing arrangment
Motor control feeder lim
its
N662N663
N663CN668-0
N668-0CN668-1
N668-1CN668-2
N668-2C
2350-25502350-2550
2350-25502350-2550
2350-25502350-2550
2350-25502350-2550
2350-2550
380480
670580
770810
10001160
1350
10001000
10001000-1350
1000-13501000-1350
1000-13501000-1350
1000-1350
rear
N660
distribution
motor control
IEC 60439-1
indoor
top/bottom
IEC 60529
IEC 61641
UP TO 6000A
690V AC
50/60Hz
12KV
3
UP TO 6000A
UP TO 42
230 V AC max.
IV
Iron-phosphated steel plate
RAL7032
1000V AC
Epoxy-polyester powder
Form 2b/3b/4a/4b
100KA
1600AUP TO 6000A
3 or 4 pols
220KA
70KA
160KA
65KA 0.5s
TT-IT-TNS-TNC
up to 250 KW
N683-BN683-BS
N683-4BN687
N687-1PN687-2P
23502350
23502350
23502350
750750
9001100
11001350
600600
600600
10001000
front
N680
distribution
motor control
IEC 60439-1
indoor
top/bottom
IEC 60529
IEC 61641
UP TO 4000A
690V AC
50/60Hz
12KV
3
UP TO 4000A
UP TO 42
230 V AC max.
IV
Iron-phosphated steel plateRAL7032
1000V AC
Epoxy-polyester powder
Form 2b/3b/4a/4b
100KA
1600AUP TO 6000A
3 or 4 pols
220A
70KA
160KA
65KA 0.5s
TT-IT-TNS-TNC
up to 250 KW
5
[ ] MCC Motor Control Center Te
chnica
l Data
PARS TABLEAU
6
[ ] MCC Motor Control Center
Power and Motor Control CentersCubicle SchematicCross - Section
PARS TABLEAU
7
[ ] MCC Motor Control Center
N 687 cubicle with"cradle" and "drawer" type equipment
N 683 cubicle with"drawer" type equipment
1-"cradle" -type equipments2-busbar tee-off unit between "cradle" and "drawer" type
equipments.3-vertical busbar supply block for "drawer''type equipments4-withdrawable "cradle equipment5-withdrawable "drawer'' type equipment
6-space for auxiliary supply busbars inter-cubicle connections and auxiliary swithgear
7-vertical auxiliary supply ousbars8-earth bar9-space for power and control cables connections10-outgoing cover (optional)
The N680 series receive " cradle-type" equipment (Air circuit-breakers rated currents 2500Amps and (moulded case circuit-breakers rated current<1250 Amps) and drawer type equipment (moulded case circuit-breakers rated current < 630 Amps,contactors rated current < 500 Amps ) for the realization of distribution or motor control switchboards.
They form a range of cubicles with the following
standardized dimensions:
- height 2350 mm
-depth :600 mm
Width is determined according to the dimensions of
the biggest equipment inside the cubicles and
according to the type and section of cables.
Frames are made up of folded sheet steel elements
bolted together,and have at their lower part a base
ensuring rigidity and avoiding thus any adjustments
during installation. They are covered with heat treated
epoxy powder paint.
Cubicles Description
PARS TABLEAU
WWW.PARSTABLEAU.COM
info@parstableau.com
Des
ign
by:H
adi T
ahm
ase
bi
+
989122410032
Cat. N
o. 01.2
015
Recommended