View
218
Download
1
Category
Preview:
Citation preview
Linear ActuatorLiterature
www.hiwinmikro.com.tw
TAIWAN EXCELLENCE
GOLD AWARD 2005
Ballscrew• For Heavy-Load Drive
TAIWAN EXCELLENCE 2004
Positioning Guideway
TAIWAN EXCELLENCE GOLD AWARD 2004
Linear Synchronous Motor• Coreless Type (LMC)
• Iron-core Type (LMS)
TAIWAN EXCELLENCE 2002
Linear Actuator• LAN for Hospital• LAM for Industrial• LAS Compact Size• LAK Controller
TAIWAN EXCELLENCE GOLD AWARD 2010, 2003
Industrial Robot• For Semiconductor & Electronic
(KK Robot)• For Automation (KS, KA Robot)
TAIWAN EXCELLENCE SILVER AWARD 2009
Linear Motor Air Bearing Platform
TAIWAN EXCELLENCE GOLD AWARD 2008
TAIWAN EXCELLENCE SILVER AWARD 2007, 2002
Linear GuidewayHG/EG/RG/MG Type• Self-Lubricating (E2)• Low Noise (Q1)• Air Jet (A1)
Positioning
Measurement System
TAIWAN EXCELLENCE GOLD AWARD 2011, 2009, 2008
TAIWAN EXCELLENCE SILVER AWARD 2006, 2001, 1993
BallscrewsGround/Rolled• High Speed
(High Dm-N Value/Super S Series)• Heavy Load (Cool type II)• Self-Lubricanting (E2)• Rotating Nut (R1)
Linear Motor X-Y Robot
TAIWAN EXCELLENCE SILVER AWARD 2006
TMS Torque Motor Rotary Table
Linear Motor Gantry
High speed High precision Multifunctional integration Ecology first Humanistic technology
Linear Actuator1. Sizing of a HIWIN Linear Actuator ............................................................................................................................. 1
2. Installation of a HIWIN Linear Actuator ................................................................................................................... 1
3. Safe Operation of a Linear Actuator .......................................................................................................................... 2
4. Features and Applications .......................................................................................................................................... 3
5. HIWIN LAM Series● LAM Model .................................................................................................................................................................... 4● LAM Specifications ....................................................................................................................................................... 5● LAM2 Model .................................................................................................................................................................. 6● LAM2 Specifications ...................................................................................................................................................... 7● LAM3 Model .................................................................................................................................................................. 8● LAM3 Specifications ...................................................................................................................................................... 9
6. HIWIN LAI Series ● LAI Model ...................................................................................................................................................................... 10● LAI Specifications ......................................................................................................................................................... 11● LAI2 Model .................................................................................................................................................................... 12● LAI2 Specifications ....................................................................................................................................................... 13
7. HIWIN LAS Series ● LAS Model ..................................................................................................................................................................... 14● LAS Specifications ........................................................................................................................................................ 15● LAS2 Model ................................................................................................................................................................... 16● LAS2 Specifications ...................................................................................................................................................... 17● LAS3 Model ................................................................................................................................................................... 18● LAS3 Specifications ...................................................................................................................................................... 19● LAS4 Model ................................................................................................................................................................... 20● LAS4 Specifications ...................................................................................................................................................... 21
8. HIWIN LAN Series ● LAN1 Model .................................................................................................................................................................. 22● LAN1 Specifications ...................................................................................................................................................... 23● LAN2 Model .................................................................................................................................................................. 24● LAN2 Specifications ...................................................................................................................................................... 25● LAN3 Model .................................................................................................................................................................. 26● LAN3 Specifications ...................................................................................................................................................... 27● LAN4 Model .................................................................................................................................................................. 28● LAN4 Specifications ...................................................................................................................................................... 29● LAN5 Model .................................................................................................................................................................. 30● LAN5 Specifications ...................................................................................................................................................... 31
9. HIWIN LAC Series ● LAC3 Model ................................................................................................................................................................... 32● LAC3 Specifications ...................................................................................................................................................... 33
10. HIWIN 1-Axis Controller● LAK2LR Model .............................................................................................................................................................. 34
11. HIWIN 2-Axis Controller● LAK2 Model ................................................................................................................................................................... 36● LAK2BN Model .............................................................................................................................................................. 38● LAK2D Model ................................................................................................................................................................ 40● LAK2J Model ................................................................................................................................................................. 42
12. HIWIN 3-Axis Controller● LAK4 Model ................................................................................................................................................................... 45
13. HIWIN 4-Axis Controller● LAK4D Model ................................................................................................................................................................ 47
● LAK4N Model ................................................................................................................................................................ 49
14. HIWIN 6-Axis Controller● LAK6B Model ................................................................................................................................................................ 51
● Over Current Setting Table ........................................................................................................................................... 53
15. HIWIN Battery ............................................................................................................................................................... 54
16. HIWIN Over Current Protection Box ......................................................................................................................... 55
17. HIWIN Keypad Series (LAP1/LAP2/LAP3/LAP3N/LAP4/LAP4G/LAP4N/LAP4M/LAP4R/LAP5/LAFS Model) ........... 57
18. Options for each Actuator Type .................................................................................................................................. 65
19. HIWIN Customer Requirements (LA) ........................................................................................................................ 67
** The specifications in this catalog are subject to change without notification.
A99LE18-1107 1
Step 1: Determine the load and speed Consider the operating environment, compare the specifications of various types of Hiwin Linear Actuators and select the most appropriate model.
Step 2: Stroke and retracted length sizing Consider the dimensions of the operating area and select the appropriate actuator.
Step 3: Duty cycleDuty cycles should not exceed 10%. If the duty cycle exceeds 10%, the life of the actuator can be reduced. Users should make sure that no torsion or impact forces are acting upon the actuator.
Step 4: Controller sizing The controller selection should be made according to the power requirements of the actuator. Other considerations include the number of axes, type of limit switches and the series of keypad.
1.
2.
Sizing of a HIWIN Linear Actuator
Installation of a HIWIN Linear Actuator
1. Please ensure that the extension tube is at the “lowest position”. The term “lowest position” refers to the position where there is no further movement towards the DC motor while the actuator is powered on.
2. The front and end joints of the linear actuator should be mounted onto two fixed positions on the main chasis. Locations of these fixed positions should be chosen according to the stroke length of the linear actuator.
3. After the fixed positions have been selected, install the fixtures onto these selected positions of themain chasis. These fixtures are used to fix the front and end joints of the linear actuator.
4. Assemble the front and end joints of the linear actuator onto the two fixtures using fixture bolts. Please ensure that the fixture bolts rotate freely when this step is completed. Also, please ensure that the fixture bolts do not become "loose" and fall off during operation.
5. The chasis of the linear actuator should be mounted in the horizontal direction if it is going to be operated in this direction and likewise for vertical operation. Damages could occur to the actuator if these instructions are not followed.
6. Make sure that: ●The travel distance of the actuator matches the design requirements. ●The upper and lower limit switches are functioning. ●The motor stops when the extension tube reaches the upper and lower limit switches.* If the actuator does not operate as described above, please repeat steps 2 thru 4 to make sure that the
installation is correct. ** All HIWIN linear actuators and control boxes have to be grounded.
A99LE18-11072
Regulations to Safely Operate HIWIN Linear Actuators3.
1. A no-load operation may damage the actuator, especially if the actuator has external limit switches installed.
2. Please make sure that the actuators are not installed where the motor or any mechanical parts can be damaged due to dangerous environments.
3. Make sure the DC voltage supplied to the actuator matches the specifications on the actuator. The power supply should supply enough power under maximum load.
4. Under extreme load situations, the motor will try to draw more than the rated current. It is the operator’s duty to ensure that the power supply does not provide more current than specified on the actuator. Excessive current will cause wiring damage and possible failure of the actuator. Unless otherwise specified, our actuators have a duty cycle rating of 10%. The duty cycle is defined as two minutes of continuous operation, followed by 18 minutes of non-operation. If the duty cycle exceeds 10%, please consider over-current protection measures. Install protection devices such as fuses or an over-current detection between the power supply and the actuator input end. Detection signals are to be used for operation interruption or shut down.
5. Thermal protection is included on some Hiwin linear actuator models. This will shut down the motor when over-heated.
6. If the actuator was purchased without limit switches, please install appropriate limit switches that comply with the power supply and over-current protection devices that are used.
7. The actuator’s motors are DC driven. When the motor is not in operation, please short the ends of the power input to provide additional locking power. Make sure the controller power is shut off prior to shorting the motor inputs. The movement of the extension tube can be reversed by changing the polarity of the voltage supplied.
8. Make sure the actuator operates within its stroke length if it is not supplied with limit switches or an over load protection device.
9. The actuator should operate within the rated load specifications.
10. Please make sure the actuator is operating within the IP rating for dust and water.
11. For applications requiring high accuracy and tight speed requirements, please inquire about Hiwin’s KK-series linear stages.
12. Electrical self locking should be implemented if the Hiwin controller is not being used. This will increase the actuator’s locking force.
A99LE18-1107 3
4-1 Features of a Linear Actuator
1. Light weight and compact structure 4. Low noise
2. User friendly 5. High rigidity
3. Simple installation 6. Competitive price
4-2 Applications
l Automation equipment l Automatic windows and doors l Automatic cupboardsl Automatic satellite antennas l Automatic wheel chairs l Automatic hospital beds l Entertainment facilities l Household appliances l Automatic drawing tables l Home care facilities l Patient liftersl Massage chairs l Traffic facilities l Office automation l Automatic PC desks l Hospitals and
rehabilitation centers l Nursing homes
Features & Applications4.
A99LE18-11074
LAM
* Stroke length 100mm * Option: (1) IP65
(2) Gear box material: Steel (Standard:Zn(85%)-AL(15%))(3) Gear box housing turned 90°(4) 36VDC motor(5) UL version only 24VDC motor specifications ((Only 24VDC certified by UL))
MOTOR CABLEMOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø7
Ø63
.5
19(150)
(123) 27
78
14 21
Ø50 Ø
33 (19.3) 13
29
Ø12.2±0.1
RL
Ø12.2±0.1
27
Screw type Ballscrew/ACME
Weight* 2.31kg
Protection IP54
Compatible controller
LAK2/LAK2LR/LAK2D/LAK2BNLAK2J/LAK4N/LAK6B
Working temp. +5oC~40oC
HIWIN LAM Series (1)5.
● LAM-1/-2 ● LAM-1ARL=S+153 RL=S+162Stroke≤400 Stroke≤400
RL=S+203 RL=S+212Stroke>400 Stroke>400
RL:Retracted lengthS:Stroke length
A99LE18-1107 5
ModelScrew type
Thrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
12VDC 24VDC
LAM-1 Ballscrew 4000 3000 4000 8 11 100 150 200 250 300 350 400 10 12 6
LAM-2 Ballscrew 2000 2000 1200 16 21 100 150 200 250 300 350 400 10 12 6
LAM-1A ACME 3000 3000 3000 8 11 100 150 200 250 300 350 400 10 12 6
LAM-1/ -2 / -1A 24(12)VDC Motor
25
20
15
10
5
0
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
Spee
d (m
m/s
)
LAM-1
LAM-2
LAM-1A
LAM-1/ -2 / -1A 24 VDC Motor
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
6
5
4
3
2
1
0
Cur
rent
(Am
p) LAM-1
LAM-2
LAM-1A
LAM-1/ -2 / -1A 12 VDC Motor
0 500 1000 1500 2000 2500 3000 3500 4000
Load (N)
12
10
8
6
4
2
0
Cur
rent
(Am
p) LAM-1
LAM-2
LAM-1A
• LAM Specifications
• Ordering Information
**Note: The test results are obtained by using the 12VDC power supply.
LAM 1 0 200 24 EModel number(Ballscrew: 1,2)(ACME: 1A)
0: Basic model (without magnet)1: Complete with external limit switches
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
**Note: The test results are obtained by using the 24VDC power supply.
A99LE18-11076
LAM2
* Stroke length 200mm * Option: (1) External reed switch.
(2) Mechanical Spline(Push only)(3) MR Sensor(Position feedback)(4) Back fixture turned 90°(5) IP66
Screw type ACME
Weight* 1.9kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
HIWIN LAM Series (2)5.
MOTOR CABLEMOTOR CABLE LENGTH=1000mm
110
6.2
71
Ø25
.9
38
Ø196.2
Ø25
.9
Ø8.1
34
(RL)
Ø10.1
136
4625
42
45
111
25
11 21.5
● RL=S+157Stroke≤300RL=S+207Stroke>300
RL:Retracted lengthS:Stroke length
A99LE18-1107 7
ModelThrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle%
Current max. (A) MR Sensor Resolution(mm/pulse)24VDC 12VDC
LAM2-1 3500 3500 3000 2 3.5 100 150 200 250 300 10 4 8 0.1
LAM2-2 2500 2500 2000 3 6 100 150 200 250 300 10 4 8 0.16
LAM2-3 1500 1500 1500 6.5 12 100 150 200 250 300 10 3 6 0.32
LAM2-4 1200 1200 800 8 14 100 1500 200 250 300 10 3 6 0.4
• LAM2 Specifications
• Ordering Information
**Note: The test results are obtained by using the 12VDC power supply.
**Note: The test results are obtained by using the 24VDC power supply.
LAM2-1/ -2 / -3 / -414
12
10
8
6
4
2
00 500 1000 1500 2000 2500 3000 3500 4000
0 500 1000 1500 2000 2500 3000 3500 4000
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
LAM-1/ -2 / -1A
0 500 1000 1500 2000 2500 3000 3500 4000
LAM2-1
LAM2-2
LAM2-3
LAM2-4
LAM2-1/ -2 / -3 / -4
LAM2-1
LAM2-2
LAM2-3
LAM2-4
LAM2-1
LAM2-2
LAM2-3
LAM2-4
8
7
6
5
4
3
2
1
0
24(12)VDC Motor
Load (N)
Spee
d (m
m/s
)
24 VDC Motor
Load (N)
Cur
rent
(Am
p)
12 VDC Motor
Load (N)
Cur
rent
(Am
p)
LAM2 1 1 200 24 G E
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
0: Without internal limit switches1: Basic model complete
with internal limit switchesColorB: BlackG: Gray
A99LE18-11078
MOTOR CABLEMOTOR CABLE LENGTH=200mmMOTOR CABLE DIAMETER=Ø5.5
98 81 66
.5 32
.7
15
154 52
39.7
14
83
13 (20.5)
29
Ø10+0.2 -0
RL
141.5 83
11
Ø25
.9
21.5
Ø10 +0.2 -0
6.2
Ø25
.4
Ø25
Screw type ACME
Weight* 2.95kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
* Stroke length 200mm * Option: (1) IP66
(2) Safety Nut (RL=S+183, S≤300/RL=S+233, S>300)(3) Back fixture turned 90o
LAM3
HIWIN LAM Series (2)5.
● RL=S+171Stroke≤300
RL=S+221Stroke>300
RL:Retracted lengthS:Stroke length
A99LE18-1107 9
LAM3-1/ -2 / -3 / -424(12) VDC Motor
0 1000 2000 3000 4000
Load (N)
20
15
10
5
0
Spee
d (m
m/s
)
LAM3-1
LAM3-2
LAM3-3
LAM3-4
5000 6000
LAM3-1/ -2 / -3 / -424 VDC Motor
0 1000 2000 3000 4000
Load (N)
6
5
4
3
2
1
0
Cur
rent
(Am
p)
LAM3-1
LAM3-2
LAM3-3
LAM3-4
5000 6000
LAM3-1/ -2 / -3 / -412 VDC Motor
0 1000 2000 3000 4000
Load (N)
Cur
rent
(Am
p)
LAM3-1
LAM3-2
LAM3-3
LAM3-4
5000 6000
12
10
8
6
4
2
0
ModelThrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
12VDC 24VDC
LAM3-1 6000 5000 5000 4 5.5 100 150 200 250 300 350 400 10 12 6
LAM3-2 4000 4000 4000 5.5 7.5 100 150 200 250 300 350 400 10 10 5
LAM3-3 3000 3000 3000 7 9 100 150 200 250 300 350 400 10 8 4
LAM3-4 2000 2000 1500 11.5 14.5 100 150 200 250 300 350 400 10 8 4
• LAM3 Specifications
**Note: The test results are obtained by using the 24VDC power supply.
• Ordering Information
LAM3 1 1 300 24 G E
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
0: Without internal limit switches1: Basic model complete
with internal limit switchesColorB: BlackG: Gray
**Note: The test results are obtained by using the 12VDC power supply.
A99LE18-110710
31
15
215
19
(L)Ø39
Ø46
127.
75
Ø28
R111
Ø59
.5
92.7515
Ø14.2±0.1
22.3
Ø28
Ø14.2±0.1
31
MOTOR CABLE MOTOR CABLE LENGTH=1000mm
• LAI-1
MOTOR CABLE MOTOR CABLE LENGTH=1000mm
31
15
215
19
(L)Ø39
Ø46
127.
75
Ø28
R111
Ø59
.5
92.75
11
Ø10±0.1
Ø21
.9
Ø14.2±0.1
24.9
22
• LAI-1A
Screw type Ballscrew/ACME
Weight* 2.4kg
Protection IP20
Compatible controller
LAK2/LAK2LR/LAK2BN/LAK4NLAK2B/LAK2J/LAK2D/LAK6B
Working temp. +5oC~40oC
LAI
HIWIN LAI Series (1)6.
● LAI-1
RL=S+170Stroke≤300
RL=S+220Stroke>300
RL:Retracted lengthS:Stroke length
* Stroke length 200mm * Option: (1) IP66
(2) Hall sensor
● LAI-1A
RL=S+190Stroke≤300
RL=S+240Stroke>300
RL:Retracted lengthS:Stroke length
A99LE18-1107 11
LAI-1/ -1A24(12) VDC Motor
0 1000 2000 3000 4000
Load (N)
10
8
6
4
Spee
d (m
m/s
)
LAI-1
LAI-1A
LAI-1/ -1A24 VDC Motor
0 1000 2000 3000 4000
Load (N)
10
8
6
4
2
0
Cur
rent
(Am
p)
LAI-1/ -1A12 VDC Motor
0 1000 2000 3000 4000
Load (N)
5
4
3
2
1
0
Cur
rent
(Am
p)
LAI-1
LAI-1A
LAI-1
LAI-1A
• LAI Specifications
ModelScrew type
Thrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
12VDC 24VDC
LAI-1 Ballscrew 4000 4000 1200 6 9 100 150 200 250 300 10 8 4
LAI-1A ACME 4000 4000 3000 6 9 100 150 200 250 300 10 10 5
**Note: The test results are obtained by using the 24VDC power supply.
**Note: The test results are obtained by using the 12VDC power supply.
• Ordering Information
LAI 1 0 200 24 EModel number(Ballscrew: 1)(ACME: 1A)
0: Basic model (without magnet)1: Complete with external limit switches
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
A99LE18-110712
Screw type Ballscrew
Weight* 8kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin
Working temp. +5oC~40oC
LAI2
HIWIN LAI Series (2)6.
* Stroke length 300mm * Option: (1) IP66
(2) Hall sensor(3) Overload clutch(4) Limit switch(5) Clamp installed(6) Installation back fixture
● L=S+78Stroke≤300
L=S+128Stroke≤700
L=S+178Stroke≤1000
S:Stroke length
148105
188
Ø56Ø
76
Ø24
46
145.
5
76.5
50
(24)11
Ø33
59
10L
Ø56Ø
76
Ø24
46
145.
5
76.5
50
(24)11
Ø33
59
10L
90
Clamp
Clamp
TypeLAI2-1-1-1000-24E
P12026A4
x x x x x x x x x x x x x x x x x x xH
IWIN
MIKR
OSYSTEM COR
P.http://w
ww
.hiwinm
ikro.com
Pow
erR
ating: 24
V,Max.3
Am
pW
eight :xx
Kg
Duty Cycle
: Max. 10 %
,Max.
2min
Stroke :
1000m
mM
ax.Speed: 2.5
mm
/sec
I.P.
: xxN
ote :
S/N
Mfg.D
ate : xxxx/xx/xx
Max.Force
:10000NM
ax.Self-locking :10000N
TypeLAI2-1-1-1000-24E
P12026A4
x x x x x x x x x x x x x x x x x x xH
IWIN
MIKR
OSYSTEM COR
P.http://w
ww
.hiwinm
ikro.com
Pow
erR
ating: 24
V,Max.3
Am
pW
eight :xx
Kg
Duty Cycle
: Max. 10 %
,Max.
2min
Stroke :
1000m
mM
ax.Speed: 2.5
mm
/sec
I.P.
: xxN
ote :
S/N
Mfg.D
ate : xxxx/xx/xx
Max.Force
:10000NM
ax.Self-locking :10000N
• With limit switch and with hall sensor drawing:
• Without limit switch and without hall sensor drawing:
A99LE18-1107 13
• LAI2 Specifications
Model Screw type
Thrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Static Load
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle%
Current max. (A)
24VDC
Hall SensorResolution(mm/pulse)
LAI2-1 Ballscrew 12000 10000 12000 50000 2 2.5 100 150 200 250 300 10 3 1.26
LAI2-2 Ballscrew 8000 8000 8000 50000 4 5 100 150 200 250 300 10 3 2.54
**Note: The test results are obtained by using the 24VDC power supply.
• Ordering Information
LAI2 1 0 200 24 EModel number
0: Basic model (without limit switchs)1: Complete with Internal limit switches
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
LAI2-1/ -2
0 2000 4000 6000 8000
5
4
3
2
1
0
LAI2-1
LAI2-2
10000 12000
LAI2-1/ -2
0 2000 4000 6000 8000
5
4
3
2
1
0
LAI2-1
LAI2-2
10000 12000
24 VDC Motor
Load (N)
Spee
d (m
m/s
)
24 VDC Motor
Load (N)
Cur
rent
(Am
p)
A99LE18-110714
MOTOR CABLEMOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5
19.5
9.5
83 73.5
Ø18
8 10 20 (RL-55) (25)
RL 9.4
(100)
Ø38
Ø19
2-Ø8.1±0.1
Ø18
.8
27
40 5
Screw type ACME
Weight* 1.04kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
* Stroke length 200mm * Option: (1) IP65
(2) Back fixture turned 90(3) Rod end with flat connector (RL=S+110, S≤250/RL=S+160, S>250)(4) 36VDC motor(5) External reed switches(6) Plastic gear (Max. load: 800N)
LAS
HIWIN LAS Series (1)7.
● RL=S+119Stroke≤250
RL=S+169Stroke>250
RL:Retracted lengthS:Stroke length
Flat connector
Ø8.1+0.2-1
A99LE18-1107 15
LAS-1/ -224(12) VDC Motor
0 200 400 600 800 1000 1200
Load (N)
30
25
20
15
10
5
0
LAS-1
LAS-2
Spee
d (m
m/s
)
LAS-1/ -224 VDC Motor
0 200 400 600 800 1000 1200
Load (N)
3.0
2.5
2.0
1.5
1.0
0.5
0
LAS-1
LAS-2
Cur
rent
(Am
p)
LAS-1/ -212 VDC Motor
0 200 400 600 800 1000 1200
Load (N)
6
5
4
3
2
1
0
LAS-1
LAS-2
Cur
rent
(Am
p)
**Note: The test results are obtained by using the 24VDC power supply.
**Note: The test results are obtained by using the 12VDC power supply.
ModelThrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
12VDC 24VDC
LAS-1 1200 1200 800 8 12 50 100 150 200 250 10 6 2.5
LAS-2 600 600 300 16 25 50 100 150 200 250 10 6 3
LAS 1 1 200 24 G E
• LAS Specifications
• Ordering Information
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
0: Without internal limit switches1: Basic model complete
with internal limit switchesColorB: BlackG: Gray (Standard)
A99LE18-110716
Screw type ACME
Weight* 1.3kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
LAS2
HIWIN LAS Series (2)7.
● RL=S+146Stroke≤250
RL=S+196Stroke>250
RL:Retracted lengthS:Stroke length
(128)
(RL-102)
RL
Ø18
128 63
4.5
MOTOR CABLE MOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5.5mm
2-Ø8.1±0.1
9.4
Ø18.
8
Ø19
(27)
Ø42
22
82.5
27
31
48
21.5
80.5
37
5
Position feedback specifications (Optical Sensor)
Supply voltage 24VDC 12VDC 5VDC
Output High level 24VDCLow level 0.2V/40mA PNP*PS. Open collector
High level 12VDCLow level 0.2V/40mA PNP*PS. Open collector
TTL
* Stroke length 200mm * Option: (1) IP65
(2) Position feedback 1: Potentiometer 10k ohm (RL=S+154, S≤250/RL=S+204, S>250) 2: Optical sensor: PNP (standard), NPN. TTL(3) 36VDC motor(4) Back fixture turned 90o
(5) Rod end with flat connector (RL=S+133, S≤250/RL=S+183, S>250)* Low noise
Flat connector
Ø8.1+0.2-1
A99LE18-1107 17
**Note: The test results are obtained by using the 24VDC power supply.
**Note: The test results are obtained by using the 12VDC power supply.
ModelThrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A) Optical SensorResolution(mm/pulse)
PotentiometerResolution(Ohm/mm)12VDC 24VDC
LAS2-1 1800 1200 1800 4.5 7 50 100 150 200 250 10 6 3 0.3175 21
LAS2-2 1200 1200 1000 8 15 50 100 150 200 250 10 6 4 0.635 10.5
LAS2 1 1 200 24 G E
• LAS2 Specifications
• Ordering Information
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
0: Without internal limit switches1: Basic model complete
with internal limit switchesColorB: BlackG: Gray (Standard)
LAS2-1/ -2
0
16
14
12
10
8
6
4
2
0
LAS2-1
LAS2-2
LAS2-1/ -2
0
6
5
4
3
2
1
0
LAS2-1
LAS2-2
LAS2-1/ -2
0
6
5
4
3
2
1
0
LAS2-1
LAS2-2
24(12) VDC Motor
Load (N)
Spee
d (m
m/s
)
24 VDC Motor
Load (N)
Cur
rent
(Am
p)
12 VDC Motor
Load (N)
Cur
rent
(Am
p)
400 800 1200 20001600200 600 1000 18001400
400 800 1200 20001600200 600 1000 18001400
400 800 1200 20001600200 600 1000 18001400
A99LE18-110718
MOTOR CABLEMOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5.5
80.5
21.5
4.5 (119)
Ø38
Ø19
8 12 61 (RL-102)RL
(29)9.4
2-Ø8.1±0.1
Ø18
.8
24
48
82.5
27
31
5
Ø18
Position feedback specifications (Optical Sensor)
Supply voltage 24VDC 12VDC 5VDC
Output High level 24VDCLow level 0.2V/40mA PNP*PS. Open collector
High level 12VDCLow level 0.2V/40mA PNP*PS. Open collector
TTL
LAS3
HIWIN LAS Series (3)7.
Screw type ACME
Weight* 1.27kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
● RL=S+146Stroke≤250
RL=S+196Stroke>250
RL:Retracted lengthS:Stroke length
* Stroke length 200mm * Option: (1) IP65
(2) Position feedback 1: Potentiometer 10k ohm (RL=S+154, S≤250/RL=S+204, S>250) 2: Optical sensor: PNP (standard), NPN. TTL(3) 36VDC motor(4) Back fixture turned 90o
(5) Rod end with flat connector (RL=S+133, S≤250/RL=S+183, S>250)
Flat connector
Ø8.1+0.2-1
A99LE18-1107 19
LAS3-1/ -2 24(12) VDC Motor
0 200 400 600 800 1000 1200
Load (N)
30
25
20
15
10
5
0
LAS3-1
LAS3-2
Spee
d (m
m/s
)
LAS3-1/ -2 24 VDC Motor
0 200 400 600 800 1000 1200
Load (N)
3.0
2.5
2.0
1.5
1.0
0.5
0
LAS3-1
LAS3-2
Cur
rent
(Am
p)
LAS3-1/ -2 12 VDC Motor
0 200 400 600 800 1000 1200
Load (N)
6
5
4
3
2
1
0
LAS3-1
LAS3-2
Cur
rent
(Am
p)
ModelThrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A) Optical SensorResolution(mm/pulse)
PotentiometerResolution(Ohm/mm)12VDC 24VDC
LAS3-1 1200 1200 800 8 12 50 100 150 200 250 10 6 2.5 0.3175 21
LAS3-2 600 600 300 16 25 50 100 150 200 250 10 6 3 0.635 10.5
LAS3 1 1 200
• LAS3 Specifications
**Note: The test results are obtained by using the 24VDC power supply.
**Note: The test results are obtained by using the 12VDC power supply.
• Ordering Information
Model number
Stroke length
0: Without internal limit switches1: Basic model complete
with internal limit switches
24 G E
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
ColorB: BlackG: Gray (Standard)
A99LE18-110720
RL
15
45
45
8.5
7
4
5
Ø18.8
29.5
Ø6.2±0.1
(27.5)
15.5
9.4
5
Ø6.1+0.1-0
MOTOR CABLEMOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5
LAS4
HIWIN LAS Series (4)7.
Screw type ACME
Weight* 1.36kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
● RL=S+222.5Stroke≤300
RL=S+272.5Stroke>300
RL:Retracted lengthS:Stroke length
* Stroke length 200mm * Option: (1) IP65 (2) Hall sensor (RL=S+226, S≤300/RL=S+276, S>300)
Position feedback specifications (Hall Sensor)
Supply voltage 24VDC 12VDC 5VDC
Output High level 24VDCLow level 0.2V/10mA sink (NPN)
High level 12VDCLow level 0.2V/10mA sink(NPN)
TTL
A99LE18-1107 21
LAS4-1/ -224(12) VDC Motor
0 200 400 600 800
Load (N)
50
40
30
20
10
0
LAS4-1
LAS4-2
Spee
d (m
m/s
)
LAS4-1/ -212 VDC Motor
0 200 400 600 800
Load (N)
6
5
4
3
2
1
0
LAS4-1
LAS4-2
Cur
rent
(Am
p)
LAS4-1/ -224 VDC Motor
0 200 400 600 800
Load (N)
4
3.5
3
2.5
2
1.5
1
0.5
0
LAS4-1
LAS4-2
Cur
rent
(Am
p)
100 300 500 700
100 300 500 700
**Note: The test results are obtained by using the 24VDC power supply.
**Note: The test results are obtained by using the 12VDC power supply.
ModelThrustmax.(N)
Pullingmax.(N)
Holdingmax.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A) Hall SensorResolution(mm/pulse)12VDC 24VDC
LAS4-1 800 800 600 10 15 100 150 200 250 300 10 5 2.3 0.0085
LAS4-2 300 300 200 30 46 100 150 200 250 300 10 6 3.6 0.02
• LAS4 Specifications
• Ordering Information
LAS4 1 1 200
Model number
Stroke length
0: Without internal limit switches1: Basic model complete
with internal limit switches
12 G E
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
ColorB: BlackG: Gray (Standard)
A99LE18-110722
MOTOR CABLE MOTOR CABLE LENGTH=300mm MOTOR CABLE DIAMETER=Ø5.5mm
78 33.5
(A)
(C) (B)
11
6.2
24.6 82.6
33
158 17
0
71
Ø26
Ø10 +0.2 -0
173.5
166
RL
7.5 (25) 11
24.9
Ø2
1.9
Ø10 +0.2 -0
54.8
50.8
57.8
LAN1
HIWIN LAN Series (1)8.
Position feedback specifications (Hall Sensor)
Supply voltage 24VDC 12VDC 5VDC
Output High level 24VDCLow level 0.2V/10mA sink (NPN)
High level 12VDCLow level 0.2V/10mA sink(NPN)
TTL
Screw type ACME
Weight* 2.6kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
● RL=S+173Stroke≤300
RL=S+223Stroke>300
RL:Retracted lengthS:Stroke length
* Stroke length 200mm * Option: (1) IP66
(2) Position feedback (3) Safety Nut (RL=S+185, S≤300/RL=S+235, S>300) (4) Mechanical Spline (push only)(RL=S+223, S≤300/RL=S+273, S>300) (5) Back fixture turned 90o (6) Mechanical quick release (RL=S+230), Only for LAN1-4 (7) Motor cable outlet: (A)Standard (B)Front (C)Back.(8) 36VDC motor(9) UL version
A99LE18-1107 23
LAN-1/ -224 VDC Motor
16141210
86420
0 1000 2000 40003000 5000 6000
Load (N)
Spee
d (m
m/s
)
LAN-1/ -224 VDC Motor
4.03.53.02.52.01.51.00.5
00 1000 2000 40003000 5000 6000
Load (N)
Cur
rent
(Am
p)
LAN1-1
LAN1-2
LAN1-1
LAN1-2
ModelThrust max.(N)
Pulling max.(N)
Holding max.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
24VDC
Hall SensorResolution(mm/pulse)
LAN1-1 6000 5000 5000 2.7 5 100 150 200 250 300 10 4 0.3
LAN1-2 4000 4000 4000 5 7 100 150 200 250 300 10 4 0.5
LAN1 1 1 1 200 24 G E
• LAN1 SpecificationsStandard Motor
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
LAN-1/ -2/ -3/ -424Q VDC Motor1816141210
86420
0 1000 2000 40003000 5000 6000Load (N)
Spee
d (m
m/s
)
LAN-1/ -2/ -3/ -424Q VDC Motor
6543210
0 1000 2000 40003000 5000 6000
Load (N)
Cur
rent
(Am
p)
LAN1-1
LAN1-2
LAN1-3
LAN1-4
LAN1-1
LAN1-2
LAN1-3
LAN1-4
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
ModelThrust max.(N)
Pulling max.(N)
Holding max.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
24VDC
Hall SensorResolution(mm/pulse)
LAN1-1 6000 5000 5000 5 7 100 150 200 250 300 10 6 0.3
LAN1-2 4000 4000 4000 7 9 100 150 200 250 300 10 6 0.4
LAN1-3 3000 3000 3000 9 11.5 100 150 200 250 300 10 6 0.5
LAN1-4 2000 2000 2000 12 17 100 150 200 250 300 10 5.5 0.8
Fast Motor 24Q
LAN-1/ -2/ -312 VDC Motor
10
8
6
4
2
00 1000 2000 40003000 5000
Load (N)
Spee
d (m
m/s
)
LAN-1/ -2/ -312 VDC Motor
12.010.5
9.07.56.04.53.01.5
00 1000 2000 40003000 5000
Load (N)
Cur
rent
(Am
p)
LAN1-1
LAN1-2
LAN1-3
LAN1-1
LAN1-2
LAN1-3
**Note: The test results are obtained by using the 12VDC power supply and holding by motor short-circuited.
ModelThrust max.(N)
Pulling max.(N)
Holding max.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
12VDC
Hall SensorResolution(mm/pulse)
LAN1-1 5000 5000 5000 3 6 100 150 200 250 300 10 11 0.3
LAN1-2 4000 4000 4000 4 8 100 150 200 250 300 10 11 0.4
LAN1-3 3000 3000 3000 5 10 100 150 200 250 300 10 10 0.5
12VDC Motor
• Ordering Information
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage24: Standard motor24Q: Fast motor12: 12VDC Standard
0: Without internal limit switches1: Basic model complete
with internal limit switches
ColorB: BlackG: Gray
Force direction1: Standard2: Suspending install, pull
A99LE18-110724
MOTOR CABLEMOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5.5mm
103.
5
Ø36
16
Ø12 +0.2 -0
Ø30
Ø21
.9
6.2
(22) 11
Ø10 +0.2 -0 18
36
200
RL
Ø36
103.5
16
21.5
11
6
LAN2
HIWIN LAN Series (2)8.
● RL=S+198Stroke≤400
RL=S+248Stroke>400
RL:Retracted lengthS:Stroke length
Position feedback specifications (Hall Sensor)
Supply voltage 24VDC 5VDC
Output High level 24VDCLow level 0.2V/10mA sink (NPN)
TTL
Screw type ACME
Weight* 3.29kg
Protection IP54
Compatible controller
LAK2/LAK2LR/LAK2DLAK2BN/LAK2J/LAK4N/LAK6B
Working temp. +5oC~40oC
* Stroke length 300mm * Option: (1) IP66
(2) Position feedback (3) Safety nut: RL=S+211, S≤400/RL=S+261, S>400(4) Spline (push only): RL=S+237, S≤400/RL=S+287, S>400(5) Mono jack-plug (Standard is stereo)(6) With down internal limit switch RL=S+202
A99LE18-1107 25
LAN2-1A/ -2A / -3A 24 VDC Motor
0 1000 2000 3000 4000 6000
Load (N)
25
20
15
10
5
0
Spee
d (m
m/s
)
LAN2-1A
LAN2-2A
LAN2-3A
5000
LAN2-1A/ -2A / -3A 24 VDC Motor
0 1000 2000 3000 4000 6000
Load (N)
8
7
6
5
4
3
2
1
0
Cur
rent
(Am
P)
LAN2-1A
LAN2-2A
LAN2-3A
5000
**Note: The test results are obtained by using the 24VDC power supply.
Model Screw typeThrust max.(N)
Holding max.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
24VDC
Hall SensorResolution(mm/pulse)
LAN2-1A ACME 6000 5000 4 6 100 150 200 250 300 350 400 10 6.5 0.3
LAN2-2A ACME 5000 5000 5 7.5 100 150 200 250 300 350 400 10 6.5 0.4
*LAN2-3A ACME 3000 3000 9 14 100 150 200 250 300 350 400 10 6.5 0.8
• LAN2 Specifications
* LAN2-3A Holding Force (Push direction only).
• Ordering Information
LAN2 1A 0 300 24 G E
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
0: Basic model 1: Complete with external
limit switches ColorB: BlackG: Gray
A99LE18-110726
MOTOR CABLEMOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5.5mm
128.
270
.15
27
1428
106
104
Ø12
8.1 Ø10
35.4
39.4
Ø25
.4
Ø25
RL
27
28
78
50.8
20 13
29
54.8
+0.2-0
+0.3
0
+0.1-0.05
LAN3
HIWIN LAN Series (3)8.
● RL=S+210Stroke<200
RL=S+260(Stroke:200~500mm)
RL:Retracted lengthS:Stroke length
* Stroke length 200mm * Option: (1) IP66
(2) Potentiometer 10K ohm (RL=S+221, S<200mm / RL= S+271, S:200~500mm) * The max. stroke lengths with potentiometer: LAN3-1 Max.250mm, LAN3-2 Max.330mm, LAN3-3 Max.420mm (3) Mechanical Spline (RL=S+252 , S<200mm / RL= S+302, S:200~500mm)(4) Safety Nut (RL=S+222 , S<200mm / RL= S+272, S:200~500mm);
Safety Nut+Mechanical Spline (RL=S+259, S<200mm / RL=S+309, S=200~500mm)(5) Mechanical quick release(6) Back fixture turned 90o
(7) Fast motor 24Q(8) 36VDC motor(9) External reed switches (RL=S+290, S<200mm / RL=S+340, S=200~500mm)(10) MR Sensor feedback
Screw type ACME
Weight* 5.31kg
Protection IP54
Compatible controller LAK4N/LAK6B/LAK2J
Working temp. +5oC~40oC
A99LE18-1107 27
LAN3-1/ -2 / -324 VDC Motor
15
10
5
00 1000 2000 40003000 5000 6000
Load (N)
Spee
d (m
m/s
)
LAN3-1LAN3-2LAN3-3
7000 8000 9000 10000
LAN3-1/ -2 / -324 VDC Motor
9876543210
0 1000 2000 40003000 5000 6000
Load (N)
Cur
rent
(Am
p)
LAN3-1LAN3-2LAN3-3
7000 8000 9000 10000
LAN3-1/ -2 / -324 VDC Motor
20
15
10
5
00 1000 2000 40003000 5000 6000
Load (N)
Spee
d (m
m/s
)
LAN3-1LAN3-2LAN3-3
7000 8000 9000 10000
LAN3-1/ -2 / -324 VDC Motor
12
10
8
6
4
2
00 1000 2000 40003000 5000 6000
Load (N)
Cur
rent
(Am
p)
LAN3-1LAN3-2LAN3-3
7000 8000 9000 10000
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
• Ordering Information
* Stroke over 200mm (included), RL=S+260
ModelThrust max.(N)
Pulling max.(N)
Holding max.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)24VDC
PotentiometerResolution(Ohm/mm)
MR Sensor Resolution(mm/pulse)
LAN3-1 10000 6000 10000 4.5 8 100 150 200 250 300 350 400 - - 10 8.3 37.5 0.16
LAN3-2 7000 6000 7000 7 9 100 150 200 250 300 350 400 450 500 10 8 28 0.22
LAN3-3 5000 5000 5000 9.5 12.5 100 150 200 250 300 350 400 450 500 10 7 22.5 0.27
• LAN3 Specifications
LAN3 1 1 1 200 24 G E
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage24: Standard motor24Q: Fast motor
ColorB: BlackG: Gray1: Basic model complete
with internal limit switches
ModelThrust max.(N)
Pulling max.(N)
Holding max.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)24VDC
PotentiometerResolution(Ohm/mm)
MR Sensor Resolution(mm/pulse)
LAN3-1 10000 6000 10000 7 11 100 150 200 250 300 350 400 - - 10 12 37.5 0.16
LAN3-2 7000 6000 7000 9 13 100 150 200 250 300 350 400 450 500 10 11 28 0.22
LAN3-3 5000 5000 5000 13 18 100 150 200 250 300 350 400 450 500 10 11 22.5 0.27
**Note: The test results are obtained by using the 24VDC power supply and holding by motor short-circuited.
Fast Motor 24Q
Force direction1: Standard2: Suspending install, pull
A99LE18-110728
94
22
87
Ø25.9 +0 -0.2
6.1 +0.2 -0
Ø10 +0.2 -0
18.6
11 24
RL 185
Ø30
(22) 11
24.9
Ø2
1.9
Ø10 +0.2 -0
6 +0
.2
-0
MOTOR CABLEMOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5.5mm
LAN4
HIWIN LAN Series (4)8.
● RL=S+160Stroke≤400
RL=S+210Stroke>400
RL:Retracted lengthS:Stroke length
* Stroke length 200mm * Option: (1) IP66
(2) Safety Nut RL=S+174, S≤400/RL=S+224, S>400(3) Mono jack-plug (Standard is stereo) (4) Mechanical spline (push only) RL=S+200, S≤400/RL=S+250, S>400
Screw type ACME
Weight* 2.33kg
Protection IP54
Compatible controller
LAK2/LAK2LR/LAK2D/LAK2BNLAK2J/LAK4N/LAK6B
Working temp. +5oC~40oC
A99LE18-1107 29
LAN4-1/ -2 / -3 / -4
24(12) VDC Motor
0 500 1000 1500 2000 2500 3000 3500
Load (N)
25
20
15
10
5
0
Spee
d (m
m/s
)
LAN4-1
LAN4-2
LAN4-3
LAN4-4
LAN4-1/ -2 / -3 / -424 VDC Motor
0 500 1000 1500 2000 2500 3000 3500
Load (N)
6
5
4
3
2
1
0
LAN4-1
LAN4-2
LAN4-3
LAN4-4
Cur
rent
(Am
p)
LAN4-1/ -2 / -3 / -412 VDC Motor
0 500 1000 1500 2000 2500 3000 3500
Load (N)
12
10
8
6
4
2
0
LAN4-1
LAN4-2
LAN4-3
LAN4-4
Cur
rent
(Am
p)
**Note: The test results are obtained by using the 24VDC power supply.
ModelThrust max.(N)
Pulling max.(N)
Holding max.(N)
Speed(mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)
24VDC 12VDC
LAN4-1 3500 3500 3500 3.5 7 100 150 200 250 300 350 400 10 6 12
LAN4-2 3000 3000 3000 4.2 9 100 150 200 250 300 350 400 10 6 12
LAN4-3 2000 2000 2000 6 13 100 150 200 250 300 350 400 10 5 12
LAN4-4 1500 1500 1500 8.5 20 100 150 200 250 300 350 400 10 5 12
• LAN4 Specifications
• Ordering Information
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
0: Basic model *1: Over-Current protection Color
B: BlackG: Gray
*Remark: The over-current protection is for over load protection, do not use for limit stop.Suggestion:To add exterual limit switch as limit positions stop.
LAN4 1 0 300 24 G E
**Note: The test results are obtained by using the 12VDC power supply.
A99LE18-110730
36
165.
5
33
Ø10.1+0.2-0
116.1
308.
2+0.2
-0
Ø78
45
35.4
Ø10.1+0.2-0
35±0.1
8.2+0
.2-0
Ø30
(28)22.1
72.6
50.8
43
(25.6)
1858.197.8
(RL)
MOTOR CABLE LENGTH=1000mmMOTOR CABLE DIAMETER=Ø5.5mm
MOTOR CABLE LENGTH=1000mm
36
165.
5
33
Ø10.1+0.2-0
116.1
308.
2+0.2
-0
Ø78
45
35.4
Ø10.1+0.2-0
35±0.1
8.2+0
.2-0
Ø30
(28)
22.1
72.6
43
(25.6)
1858.1
97.8Wire housingLENGTH=1000mm
Quick release wire7x7xØ1.5
(100)
Ø50Ø44
17.9
(RL)
50.8
MOTOR CABLE DIAMETER=Ø5.5mm
QUICK RELEASE
LAN5
HIWIN LAN Series (5)8.
● RL=S+163Stroke≤300
RL=S+213Stroke>300
RL:Retracted lengthS:Stroke length
* Stroke length 200mm * Option: (1) Hall Sensor (2) Safety nut (3) Mechanical Spline (push only) (4) Back fixture turned 0°, 45°, 90°, 135° (5) IP65; IP66 (6) Back fixture and rodeye hole Ø12.1mm (7) Quick release (For LAN5-3, LAN5-4 only) (8) UL version
Screw type ACME
Weight* 1.96kg
Protection IP54
Compatible controller
Compatible with all kinds of controller
(*Notice the type of connector: Audio/DIN 4PIN)
Working temp. +5oC~40oC
Position feedback specifications (Hall Sensor)
Supply voltage 24VDC 12VDC 5VDC
Output High level 24VDCLow level 0.2V/10mA sink (NPN)
High level 12VDCLow level 0.2V/10mA sink(NPN)
TTL
Quick release function:
(1) The quick release cable can be pulled while the load on actuator under 100N.
(2) When the quick release is actived, the actuator must have a load over 700N to ensure the actuator runs inwards.
(3) After quick release actived, it may be necessary to run the actuator inwards.
A99LE18-1107 31
LAN5-1/ -2 / -3 / -4
0 1000 2000 3000
Load (N)
109876543210
Spee
d (m
m/s
)
4000 5000 6000 7000 8000
LAN5-1LAN5-2LAN5-3LAN5-4
LAN5-1/ -2 / -3 / -4
0 1000 2000 3000
Load (N)
5.04.54.03.53.02.52.01.51.00.5
0
Cur
rent
(Am
p)
4000 5000 6000 7000 8000
LAN5-1LAN5-2LAN5-3LAN5-4
LAN5-1 (24)
0 100 150 200S (mm)
8000
7000
6000
5000
4000
0
Load
(N)
250 300 350 400 450
LAN5-1-250LAN5-1-300
LAN5-1/ -2 / -3 / -4
0 1000 2000 3000
Load (N)
201816141210
86420
Spee
d (m
m/s
)
4000 5000 6000 7000 8000
LAN5-1LAN5-2LAN5-3LAN5-4
LAN5-1/ -2 / -3 / -4
0 1000 2000 3000
Load (N)
8.57.56.55.54.53.52.51.50.5
0
Cur
rent
(Am
p)
4000 5000 6000 7000 8000
LAN5-1LAN5-2LAN5-3LAN5-4
0 100 150 200S (mm)
8000
7000
6000
5000
4000
0
Load
(N)
250 300 350 400 450
LAN5-1-250LAN5-1-300
LAN5-1(24Q)
**Note: The test results are obtained by using the 24VDC power supply.
ModelThrust max.
(N)Pulling max.
(N)Holding max.
(N) Speed (mm/s)
Load=Max./Load=0Standard stroke
(mm) : S
Duty cycle
%
Current max. (A)24VDC
Hall SensorResolution(mm/pulse)
LAN5-1 8000 4000 6000 2 3.5 100 150 200 250 300 10 5 0.08LAN5-2 6000 4000 5000 3 4.5 100 150 200 250 300 10 4.5 0.10LAN5-3 4000 3000 4000 4 5.5 100 150 200 250 300 10 4 0.14LAN5-4 3000 2000 1500 6 9 100 150 200 250 300 10 4 0.22
*When the stroke of LAN5-1 is between 250mm and 300mm, refer to the diagram on the right for max. load.* LAN5-3 24V Quick release Holding max. 3000N* LAN5-4 24V Quick release Holding max. 1000N
• LAN5(24V) Specifications
• Ordering Information
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage24: Standard motor24Q: Fast motor
ColorB: BlackG: Gray
LAN5 11 1 200 24 G EModel number
Stroke length
Thrust 1: Standard2: Suspending install, pull
1: Basic model complete with internal limit switches
ModelThrust max.
(N)Pulling max.
(N)Holding max.
(N) Speed (mm/s)
Load=Max./Load=0Standard stroke
(mm) : S
Duty cycle
%
Current max. (A)24VDC
Hall SensorResolution(mm/pulse)
LAN5-1 7000 4000 6000 5 7 100 150 200 250 300 10 8 0.08LAN5-2 6000 4000 5000 7 9 100 150 200 250 300 10 8 0.10LAN5-3 4000 3000 4000 9 11 100 150 200 250 300 10 6 0.14LAN5-4 3000 2000 1500 14 19 100 150 200 250 300 10 6 0.22
*When the stroke of LAN5-1 is between 250mm and 300mm, refer to the diagram on the right for max. load.* LAN5-3 24Q Quick release Holding max. 3000N* LAN5-4 24Q Quick release Holding max. 1000N
• LAN5(24Q) Specifications
A99LE18-110732
LAC3
HIWIN LAC3 Series9.
* Stroke length 400mm * Option: Position Feedback; Potentiometer; Hall sensor
Screw type ACME
Weight* 8.1kg
Protection IP54
Compatible controller
Compatible with all controllers(*Notice the type of connector: Audio/DIN 4pin)
Working temp. +5oC~40oC
RL
Ø80
6-60° 6-M6x1Px12DP
239.37
MOTOR CABLEMOTOR CABLE LENGTH=1000mm
77
Ø49
.5
35
35
138.
4
4-M8x1.25Px14DP
MOTOR CABLE DIAMETER=Ø5.5mm
● RL=171+S/2
RL:Retracted lengthS:Stroke length
A99LE18-1107 33
LAC324 VDC Motor
0 500 1000 1500 2000
Load (N)
141210
86420
Spee
d (m
m/s
)
LAC324 VDC Motor
0 500 1000 1500 2000
Load (N)
5
4
3
2
1
0
Cur
rent
(Am
p)
**Note: The test results are obtained by using the 24VDC power supply.
ModelThrust max.(N)
Pulling max.(N)
Holding max.(N)
Speed (mm/s)Load=Max./Load=0
Standard stroke (mm) : S
Duty cycle
%
Current max. (A)24VDC
PotentiometerResolution(ohm/mm)
Hall SensorResolution(mm/pulse)
LAC3-1 2000 500 2000 8 12 300 400 500 10 5 6.67 1.0
• LAC3 Specifications
• Ordering Information
Model number
Stroke length
Special models according tothe customer’s requirement(Ignore this part of the serial number if not available)
Voltage
1: Basic model complete with internal limit switches
ColorG: Gray
LAC3 1 1 400 24 G E
• LAC3 Bending moment illustrationLeft Right
Bending momentDynamic: max. 200NmStatic: max. 500Nm
Load
Bending momentDynamic: max. 200NmStatic: max. 500Nm
A99LE18-110734
LAK2LR
HIWIN 1-Axis Controller10.
159.
5
92
68
180
167
4-Ø5.5
173
67.5
8
AC In Keypad Motor1 2
• Features of the LAK2LR- Controls 1 linear Actuator- Controls 1 Actuator with external limit switches- OLP (Over Load Protection)- Standard cable length: 4M- Electronic protection for the relays
Input voltage AC 100/110/220/230V
Output power 108VA(24VDC)max
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: IP66
A99LE18-1107 35
Power
HIWINLAP2-2
• Ordering Information
LAK2LR - G - 110 - B ESpecial models according toClient’s requirement
NoneE=Special requirement
Color B: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
Actuator No. 1 G: LAM-1/-2/-1A; LAN2
• For Series LAM, LAN2 completed with external limit switches
* Check attached table for over current setting...see page 53.* The keypad of the LAK2LR is not the same as LAK2L.
A99LE18-110736
LAK2
HIWIN 2-Axis Controller1 1 .
Power
HIWINLAP2-2
159.
5
92
68
180
167
4-Ø5.5
173
67.5
8
AC In Keypad Motor1 2
Input voltage AC 100/110/220/230V
Output power 108VA(24VDC)max
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: (1) IP66(2) DC 12V In & Out(3) DC 24V In & Out
• Features of LAK2- Control 1 or 2 Linear Actuators - Over load protection - Standard cable length: AC:4M/DC:1M- Electronic protection of the relays
• For Series LAS, LAS3, LAS4, LAM, LAN1, LAN2
A99LE18-1107 37
LAK2 - B 0 - 110 - B ESpecial models according toClient’s requirement
NoneE=Special requirement
Color B: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
Actuator No. 2 0: NoneA: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2E: LAN4-3/-4F: LAN4-1/-2G: LAM-1/-2/-1A; LAN2
Actuator No. 1 A: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2E: LAN4-3/-4F: LAN4-1/-2G: LAM-1/-2/-1A; LAN2
LAK2 - E 0 - 12 - B ESpecial models according toClient’s requirement
NoneE=Special requirement
Color B: BlackG: Gray
Input Voltage 12: 12VDC24: 24VDC
Actuator No. 2 0: NoneA: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2E: LAS-1(12V); LAS3-1(12V/); LAS4-1(12V)F: LAS-2(12V); LAS3-2(12V)G: LAM-1/-2/-1A; LAN2L: LAN1-1/-2/-3(12V); LAM-1/-2/-1A)
Actuator No. 1 A: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2E: LAS-1(12V); LAS3-1(12V); LAS4-1(12V)F: LAS-2(12V); LAS3-2(12V)G: LAM-1/-2/-1A; LAN2L: LAN1-1/-2/-3(12V); LAM-1/-2/-1A
• Ordering Information
* Standard cable: 1M in length with 3 flying lead termination.* Check attached table for over current setting...see page 53.
* Check attached table for over current setting...see page 53.
A99LE18-110738
245230
173
107
91
Ø4.5
100
6.5
22066 10
46
AC In DC in KP 1 2
245
230
173
107 91 123
4-Ø4.5
100
6.5
22066
37
10
137
46
AC In DC in KP 1 2
230245
91107
4-Ø4.5
KP 1 2DC in
AC in
6.5
100
66
LAK2BN
HIWIN 2-Axis Controller1 1 .
1.5 2 2.5 3 3.5 4 5 6
Current vs. Durable Period under Load (1.3Ah)
Tim
e (m
in)
7570656055504540353025201510
50
Current (A)
70
60
48
39
28
1712
8
1 For 1.3Ah Battery
2 For 2.9Ah Battery
Input voltage AC 100/110/220/230V
Output power 144VA(24VDC)max
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: (1) IP66(2) Custom program(3) Two axes move simultaneously(4) Two axes move synchronously (Actuators must have feedback)
• Features of LAK2BN- Control 1 or 2 Linear Actuators- Compact size- Over load protection- Soft - start / stop- Standard cable length: 4M- Rechargeable Battery- Low battery indicator (alarm) - Battery capacity: 1.3Ah (12VDCx2) (Option: 2.9Ah, 12VDCx2)
*Note: Please charge battery for at least 8 hours before initial use.
0 No Battery box
A99LE18-1107 39
• Ordering Information (LAK2BN)
• For Series LAS4, LAN1 and LAM3
LAK2BN - 1 - D 0 - 110 - B ESpecial models according toClient’s requirement
NoneE=Special requirement
Color B: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
Actuator No. 2 0: NoneA: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2D: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAM3-1; LAN4-1/-2
Actuator No. 1 A: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2D: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAM3-1; LAN4-1/-2
Battery 0: None Battery box1: 1.3Ah2: 2.9Ah
* Check attached table for over current setting...see page 53.
A99LE18-110740
LAK2D
HIWIN 2-Axis Controller1 1 .8
27.8
3.3
5.08
10
4.7
AC
In76
10010.2
117.8 16.37.3
186
R2 R2
15
Ø4.2
KP
12
Input voltage AC 100/110/220/
230V(50/60Hz)
Output power 108VA(24VDC)max
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: IP66
A99LE18-1107 41
HIWINLAP1-2
Power
• Ordering Information
• Features of LAK2D- Control 1 or 2 Linear Actuators- Standard cable length: 4M - Over load protection - During an emergency power loss, please insert 2-9V alkaline batteries to lower the actuators. (Protection class is
IP54 when LAK2D is operated with batteries)- Can be mounted directly on the LAM3 or LAN5* There is no battery charge function, the 9V batteries are used for emergencies only.
• For Series LAS, LAS3, LAS4, LAM3, LAN1, LAN5, only the LAM3 and LAN5 can mounted directly onto the LAK2D
LAK2D - 1 - D 0 - 110 - G ESpecial models according toClient’s requirement
NoneE=Special requirement
Color W: WhiteB: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
Actuator No. 2 0: NoneB: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2D: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3(24Q);LAN4-1/-2; LAM3-1
Actuator No. 1 B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2D: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3(24Q);LAN4-1/-2; LAM3-1
Battery 0: None1: 9-volt alkaine battery
* Check attached table for over current setting...see page 53.* LAK2D over current must be set to the same value.
A99LE18-110742
LAK2J
HIWIN 2-Axis Controller1 1 .
Output power DC 24V
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: (1) IP65(2) Custom program
STOP
402
426.
9
408.
5
125
88112.
5
68
24
BATTERY
EMERGENCY
KP 1 2
OC1
2
A99LE18-1107 43
50%
55%
60%
65%
70%
75%
80%
85%
90%
95%
100%
0 5 10 15 20 25 30 35 40 45 5023.5
24
24.5
25
25.5
26
26.5
27
Battery Capacity and voltage VS. Number of cycles
Bat
tery
Vol
tage
(V)
Bat
tery
Cap
acit
y
Number of Cycles
VoltageCapacity
STOP
Power
LAP3-2
BATTERY
EMERGENCY
KP 1 2
LAK2J - 11 - HH - 01 - 24 - W - E Special models according toClient’s requirement
NoneE=Special requirement
Color W: WhiteG: Gray
Output power DC: 24V
Software function 01: Standard
Actuator No.2 C: LAI-1D: LAM3-3/-4; LAN1-1/-2; LAI-1A; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAM3-1; LAN1-1/-2/-3/-4(24Q); LAN4-1/-2G: LAN2; LAM-1/-2/-1AH: LAN3
Actuator No.1 C: LAI-1D: LAM3-3/-4; LAN1-1/-2; LAI-1A; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAM3-1; LAN1-1/-2/-3/-4(24Q); LAN4-1/-2G: LAN2; LAM-1/-2/-1AH: LAN3
Power 1: DC in charger by LAKCH-A2: AC in charger (100~230VAC, 50~60HZ)
Battery type 1: 4.5Ah
• Ordering Information
• Features of LAK2J- Portable design (operated by battery) - Control 1 to 2 Linear Actuators - Emergency stop button - Emergency operation through front panel (only for axis 1) - Over load protection - Soft - start / stop- Battery rechargeable via LAKCH charger - Automatic alarm when the battery is low- Automatic Energy Saving Mode- Battery capacity 4.5Ah (12VDC*2)- LED for power indication
*Note: Please charge the battery for at least 12 hours before the initial use
• For series LAN3 and LAN1
• Battery Characteristics
*Test results are obtained under 5A load current
A99LE18-110744
• Charger/Battery
LAKCH - A - 24 - BColor B: Black
Output power DC: 24V
External charger for LAK2J-11
• Ordering Information
LAKCH - B - 24 - W ESpecial models according toClient’s requirement
NoneE=Special requirement
Color W: White G : Gray
Output power DC: 24V
Wall charger
Input Voltage: AC 100 - 230V (50/60HZ)Output Voltage: DC 27V - 1A
AC IN
(125)
(90.
5)
36
(401
.6)
Power
BATTERY
CHARGER
Cable length=4MColor:Black
KP 1
115.262.3
37.8
LENGTH=1.4M
LENGTH=1.7M
Charger : LAKCH-B Charger : LAKCH-A
A99LE18-1107 45
200
152
66.5
3-Ø5
10
161
11.5
145
3-R8
8935
2Motor1KeypadAC In 3 4
15.5
LAK4
HIWIN 3-Axis Controller1 2 .
Input voltage AC 100/110/120/220/
230V(50/60Hz)
Output power 72.5VA(24VDC)max
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: (1) IP66 (2) UL versiononly for LAK4-F000-110-B
A99LE18-110746
LAP 414
HIWIN
Power
• Ordering Information
LAK4 - D 000 - 110 - B E
Special models according toClient’s requirement
NoneE=Special requirement
Color B: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
Actuator No. 2 ~ No. 3 0: NoneD: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3(24Q); LAN4-1/2; LAM3-1
Actuator No. 1 D: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3(24Q); LAN4-1/2; LAM3-1
• Features of LAK4- Control 1 to 3 Actuators- Can be mounted directly on the LAN1- Standard cable length: 4M
• For Series LAM3 and the LAN1, only LAN1 can mounted directly onto the LAK4.
Note: Please select the LAK4N for applications incorporating 3 axis.
A99LE18-1107 47
LAK4D
HIWIN 4-Axis Controller (1)1 3 .
Input voltage AC 100/110/120/220/230V
Output power 72.5VA(24VDC)Max
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: (1) IP66(2) Output power: 144VA, 216VA(3) UL Version
Keypad
Axis 1
Axis 2
Axis 3
Axis 4
155.
5
189.9
22.2
95.7
29
140.
9
16.1
2.7
25.335.2 46.9
A99LE18-110748
• Features of the LAK4D- Control 1 to 4 Linear Actuator- Standard cable length: 4M- Detachable cable retainer (protection against accidental unplugging)- Removable AC power cable.- External ground and LED power display.- Can be mounted directly on the LAN5. (LAN5 min. RL must be greater than 300mm)
• For Series LAN1, LAN5, LAM3, only the LAN5 can mounted directly on LAK4D.
Special models according toClient’s requirement
NoneE=Ignore this part of the serial number if not available
Color B: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
Actuator No. 2 ~ No. 4 0: NoneD: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3(24Q); LAN4-1/-2; LAM3-1
Actuator No. 1 D: LAN1-1/-2; LAM3-3/-4; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3(24Q); LAN4-1/-2; LAM3-1
• Ordering Information
LAK4D - D 000 - 110 - G E
LAP4G-4
Power
A99LE18-1107 49
LAK4N
HIWIN 4-Axis Controller (2)1 3 .
Input voltage AC 100/110/220/230V
Output power 216VA(DC 24V)Max
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: (1) IP66(2) Custom program(3) Two axes move simultaneously(4) Two axes move synchronously (Actuators must have feedback)
207.4215.9
5017
DC IN BT KP 1 2 3 4
124.
7
114.
7
157.
7
7.7
3-Ø5.4
44.9
207.4
73.6
80.3
A99LE18-110750
• Features of LAK4N- Control 1 to 4 Linear Actuators - Over Load protection - Standard cable length: 4M - Removable AC power cable- Detachable cable retainer for accidental unplugging protection - Soft - start / stop- LED for power indication - External battery input- External DC input (LAKB-1/-2) - Can be mounted directly on LAN1- Reconfigurable simultaneous movement- Microprocessor (Software version) can receive the singal of hall sensor, optical sensor or potentiometer* Note: Simultaneous or Synchronous movement is not available for the LAN3-1/-2/-3(24Q)
• For Series LAN1, LAM, LAM3, LAN3 and LAN5, only LAN1 can mounted directly on LAK4N.
• Ordering Information
HIWIN
LAP4-3
Power
BATTERY
External Transformer
LAK4N - 1 - C000 - 01 - 110 - G E
Special models according toClient’s requirement
NoneE=Ignore this part of the serial number if not available
Color B: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
Type 01: Standard software02: Custom software
Actuator No.4 0: NoneC: LAI-1D: LAN1-1/-2; LAM3-3/-4; LAI-1A; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3/-4(24Q); LAN4-1/-2; LAM3-1G: LAM-1/-2/1A; LAN2H: LAN3J: LAN3-1/-2/-3(24Q)
Actuator No.1 ~ No.3 C: LAI-1D: LAN1-1/-2; LAM3-3/-4; LAI-1A; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3/-4(24Q); LAN4-1/-2; LAM3-1G: LAM-1/-2/1A; LAN2H: LAN3J: LAN3-1/-2/-3(24Q)
External power 0: None1: 1.3Ah battery 2: 2.9Ah battery 3: External power (216VA Transformer) 4: With 2.9Ah battery and external power
(216VA Transformer)
* Check attached table for over current setting...see page 53.
A99LE18-1107 51
130.
9
113.
8
327.3
306
5.5
7.3
85
8
Ø9
92.5
92
327.3
LAK6B
HIWIN 6-Axis Controller1 4 .
Input voltage AC 100/110/220/230V
Output power 216VA(24VDC)max
Duty cycle 10%
Working temp +5oC~40oC
Protection* IP54
* Option: (1) IP66(2) Custom Program
A99LE18-110752
• Features of LAK6B- Control 1 to 6 Linear Actuators- Over load protection- Soft-start- Standard cable length: 4M- Rechargeable battery- Low battery indicator (alarm)- Automatic energy saving- Battery capacity 1.3Ah (12VDCx2)- Main fuse replaceable by external plug- Spare fuse inside the fuse plug- External ground connection- LED power indication* Note: Simultaneous movement is not available for LAN3-1/-2/-3(24Q)* Note: Please charge battery for at least 8 hours before initial use.
1.5 2 2.5 3 3.5 4 5 6
Current vs. Durable Period under Load (1.3Ah)
Tim
e (m
in)
7570656055504540353025201510
50
Current (A)
70
60
48
39
28
1712
8
• Ordering Information
* Check attached table for over current setting...see page 53.
• For Series LAS4, LAM3, LAN1 and LAN3:(Duty cycle rating 10%)
LAK6B - 1 - D 00000 - 00 - 110 - G ESpecial models according toClient’s requirement
NoneE=Ignore this part of the serial number if not available
Color B: BlackG: Gray
Input Voltage 100: AC100V; 110: AC110V220: AC220V; 230: AC230V
00: Standard01: Custom software
Actuator No. 2~No. 6 0: NoneA: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2; LAI-1D: LAN1-1/-2; LAM3-3/-4; LAI-1A; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3/-4(24Q); LAN4-1/-2; LAM3-1G: LAM-1/-2/-1A; LAN2H: LAN3J: LAN3-1/-2/-3(24Q)
Actuator No. 1 A: LAS4-1B: LAS-1; LAS3-1C: LAS-2; LAS3-2; LAS4-2; LAI-1D: LAN1-1/-2; LAM3-3/-4; LAI-1A; LAN5-2/-3/-4E: LAM3-2; LAN4-3/-4; LAC3-1; LAN5-1F: LAN1-1/-2/-3/-4(24Q); LAN4-1/-2; LAM3-1G: LAM-1/-2/-1A; LAN2H: LAN3J: LAN3-1/-2/-3(24Q)
Battery 0: No1: 1.3Ah
A99LE18-1107 53
• Over Current Setting TableCode No.
Currentsetting
Actuator Model Controller Model
A 2.5A LAS4-1LAK2; LAK2D; LAK2LR; AK2BN; LAK2J; LAK4; LAK4N; LAK4D; LAK6B
B 3.0A LAS-1; LAS3-1; LAM2-3/-4; LAI2-1; LAS2-1LAK2; LAK2D; LAK2LR; AK2BN; LAK2J; LAK4; LAK4N; LAK4D; LAK6B
C 4.0ALAS-2; LAS3-2; LAS4-2; LAI-1(24V); LAM2-1/-2; LAI2-2; LAS2-2
LAK2; LAK2LR; LAK2D; LAK2BN; LAK4; LAK4N; LAK6B
D 5.0A LAM3-3/-4; LAN1-1/-2; LAI-1A(24V); LAN5-2/-3/-4LAK2; LAK2D; LAK2LR; LAK2BN; LAK2J; LAK4; LAK4N; LAK4D; LAK6B
E(24V) 6.0A LAM3-2; LAN4; LAC3-1; LAN4-3/-4; LAN5-1 LAK2D; LAK2BN; LAK2J; LAK4; LAK4N; LAK4D; LAK6B
E(12V) 6.0ALAS-1(12V); LAS3-1(12V); LAS4-1(12V); LAM2-3/-4; LAS2-1/-2
LAK2(DC)
F(24V) 7.0ALAN1-1/-2/-3/-4(24Q); LAM3-1; LAN4-1/-2LAN5-3/-4(24Q)
LAK2; LAK2D; LAK2LR; LAK2BN; LAK2J; LAK4; LAK4N; LAK4D; LAK6B
F(12V) 7.0A LAS-2(12V); LAS3-2(12V); LAS4-2(12V) LAK2(DC)
G(24V) 8.0A LAM-1/-2/-1A; LAN2; LAN5-1/-2(24Q) LAK2; LAK2LR; LAK4N; LAK6B
G(12V) 8.0A LAI-1(12V); LAM-1/-2 LAK2(DC)
H(24V) 9.0A LAN3 LAK6B; LAK4N
H(12V) 9.0A LAI-1A(12V) LAK2(DC)
I 10A For reservation
J 12A LAN3-1/-2/-3(24Q) LAK4N; LAK6B
K 14A For reservation
L 15ALAN1-1/-2/-3(12V); LAM-1/-2/-1A(12V), -2A(12V)LAM3(12V); LAN4(12V)
LAK2(DC)
Z **A Special current value (special requirement)
• LA Cable connector Vs. controller model
Controller Model
LAK2LR LAK2BN LAK2D LAK2 LAK2J LAK4 LAK4D LAK4N LAK6B
Normal connector
audio 4pin 4pin audio audio 4pin 4pin 4pin 4pin
Act
uato
r M
odel
LAM bare wire to audio to 4pin to 4pin to audio to audio to 4pin to 4pin to 4pin to 4pin
LAM2 4pin to audio normal normal to audio to audio normal normal normal normal
LAM3 4pin to audio normal normal to audio to audio normal normal normal normal
LAI bare wire to audio to 4pin to 4pin to audio to audio to 4pin to 4pin to 4pin to 4pin
LAI2 bare wire to audio to 4pin to 4pin to audio to audio to 4pin to 4pin to 4pin to 4pin
LAS bare wire to audio to 4pin to 4pin to audio to audio to 4pin to 4pin to 4pin to 4pin
LAS2 bare wire to audio to 4pin to 4pin to audio to audio to 4pin to 4pin to 4pin to 4pin
LAS3 bare wire to audio to 4pin to 4pin to audio to audio to 4pin to 4pin to 4pin to 4pin
LAS4 bare wire to audio to 4pin to 4pin to audio to audio to 4pin to 4pin to 4pin to 4pin
LAN1 4pin to audio normal normal to audio to audio normal normal normal normal
LAN2 audio normal to 4pin to 4pin normal normal to 4pin to 4pin to 4pin to 4pin
LAN3 4pin to audio normal normal to audio to audio normal normal normal normal
LAN4 audio normal to 4pin to 4pin normal normal to 4pin to 4pin to 4pin to 4pin
LAN5 4pin to audio normal normal to audio to audio normal normal normal normal
LAC3 4pin to audio normal normal to audio to audio normal normal normal normal
A99LE18-110754
• Ordering Information (Battery)
LAKB - 1 - G ESpecial models according toClient’s requirement
NoneE=Ignore this part of the serial number if
not available
Color B: BlackG: Gray
Battery 1: 1.3Ah2: 2.9Ah
LAKB - 3 - G - ESpecial model according to Client’s requirement
NoneE=Ignore this part of the serial number if not available
Color W: White G: Gray
Battery for LAK2J 3: 4.5Ah
HIWIN Battery1 5 .
(125)(2
65)
(87)
EATTERY
155
108
156.7
(134
.9)
60.6
Cable Length=120mm
Battery: LAKB-1
Cable Length=120mm
156.5155
123
(150
)97
.6
Battery: LAKB-2
Battery: LAKB-3
A99LE18-1107 55
LAKC-1
HIWIN Over Current Protection Box1 6 .
POWER IN (12 / 24 VDC)
Male
POWER OUT (12 / 24 VDC)
Female
White(-)
Black(+)
BlackWhite
505
9
8
R4
550
36.5
89.8
11 5
89.8
81.1
83.3
98.2±0.5
56.3
35.3
8.7
6.4 10.9
5.2
58.3
Input voltage 12/24VDC
Output voltage 12/24VDC
Duty cycle 10%
Working temp. +5oC~40oC
Protection* IP54
* Option: IP66
A99LE18-110756
POWER IN (12 / 24 VDC)
*
* When purchasing an actuator to be connected with the LAKC, please inform the Hiwin sales representative.
• Features of LAKC-1- Compact size
- Low cost
- Easy to use
- Multiple over- current settings available
- Fast response time
• For Series
LAKC - 1 - 12 - 6 G ESpecial models according toClient’s requirement
NoneE=Ignore this part of the serial number if not available
Color B: BlackG: Gray
Over Current Setting 12V:2: 2A 3: 3A 4: 4A 5: 5A 6: 6A8: 8A10: 10A12: 12A18: 18A
24V:2: 2A2.5: 2.5A3: 3A4: 4A5: 5A6: 6A7: 7A8: 8A9: 9A10: 10A
Input(Output)Voltage 12: 12VDC24: 24VDC
Model number
• Ordering Information
A99LE18-1107 57
167 13
433
Ø15
54.1
Power
5320
23
55
HIWINLAP1-2
164.
9
76.6
44.1
39.7
R7.5
25
Ø15
25.3
52.220
Power
HIWINLAP212
LAP1
HIWIN Keypad Series1 7 .
LAP2
• Features of the LAP1- Controls a maximum of 2 Actuators- Compatible with the LAK2, LAK4, LAK4D, LAK4N, LAK2LR, & the LAK2D- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- Protection: IP66
• Features of the LAP2- Control maximum of 2 Actuators- Compatible with LAK2, LAK4, LAK2D- Ergonomic design and small size- Standard cable length: coil 600mm; total 1100mm- Protection: IP66
A99LE18-110758
Power
167
134
20
53
23
Ø15
54.1
55
• Features of the LAP3- Control maximum of 2 Actuators- Compatible with LAK2B, LAK2J- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- LED for battery capacity- Protection: IP66* Option: UL version only for LAP3-1-B
LAP3
Power
167
134
20
53
23
Ø15
54.1
55
• Features of the LAP3N- Control maximum of 2 Actuators- Compatible with LAK2BN- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- LED for battery capacity- Protection: IP66
LAP3N
A99LE18-1107 59
212 17
9
5053
20 50
26
Ø15
• Features of the LAP4- Control maximum of 4 Actuators- Compatible with LAK4- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- Protection: IP66- UL version only for LAP4-3-B* Option: (1) Cable length: coil 600mm; total 2250mm
(2) UL version only for LAP4-3-B
LAP4
LAP4G
• Features of the LAP4G- Control maximum of 4 Actuators- Compatible with LAK4D, LAK4N, LAK6B - Ergonomic design- Standard cable length : coil 600mm; total 1100mm- Protection: IP66- With lock function* Option: (1) UL version
(2) Cable length:coil 600mm; total 2250mm
65
170
LAP4G-4
179.
533
212.
5
21.858.2
Ø15
A99LE18-110760
212 17
9
50
Ø15
502053
26
LAP4R
• Features of the LAP4R- Control maximum of 4 Actuators- Compatible with LAK4, LAK4D, LAK4N, LAK2J, LAK6B- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- Protection: IP66* Option: Cable length: coil 600mm; total 2250mm
212 17
9
5053
20 50
26
Ø15
LAP4N
• Features of the LAP4N- Control maximum of 4 Actuators- Compatible with LAK4N, LAK4D- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- Protection: IP66* Option:Cable length:Coil 600mm; total 2250mm
A99LE18-1107 61
Ø15
HIWINLAP4M
50
212 17
9
53
2050
26
LAP4M
• Features of the LAP4M- Control maximum of 4 Actuators- Compatible with LAK4, LAK4D, LAK4N- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- Protection: IP66* Option: Cable length: coil 600mm; total 2250mm
• Features of the LAP5- Control maximum of 5 Actuators- Compatible with LAK6B, LAK2J- Ergonomic design- Standard cable length: coil 600mm; total 1100mm- Protection: IP66
LAP1 - 2 - B ESpecial models according toClient’s requirement
NoneE=Ignore this part of the serial number if not available
Color B: BlackG: Gray
Number of axis controlled
Model number LAP1 LAP4 LAP4N LAP4GLAP2 LAP4M LAP4RLAP3 LAP3N LAP5
• Ordering Information
LAP5
Ø15
5053
2050
212 17
9
26
Power
LAP5-5
HIWIN
A99LE18-110762
LAPM
LAPM - 1 - R ESpecial models according to client's requirement None
E = lgnore this part of the serial number if not available
R: Right sideL: Left side
Model number
• Features of the LAPM-Control maximum of 4 Actuators-Compatible with LAK4D, LAK4N, LAK6B-Cable length:200mm
• Ordering information
120±0.2(L)
70±0
.2
4-R10
0.6±
0.1
Right Side
A99LE18-1107 63
LACP2
LACP2 - 2 - B ESpecial models according to client's requirement None
E = lgnore this part of the serial number if not available
Color B : BlackG : Gray
Number of axis controlled
Model number
• Features of the LACP2-Control maximum of 5 Actuators-Compatible with LAK6B-Ergonomic design-Custom mask and function-Standard cable length:coil 600mm;total 1100mm-Protection: IP54-Option: IP66
185
125
143
(172
.2)
65.529.4
23.5
(29.5)
(33.5)
STOP
CPR
LACP2
- +
S
2-Copper Nut M5x12mm
• Ordering information
A99LE18-110764
LAFS
2512
5
157 37
LAFS1 - 1 - GESpecial models according toClient’s requirement
NoneE=Ignore this part of the serial number if not available
Color G: Gray
Number of axis controlled
Model number LAFS1
• Ordering Information
• Features of the LAFS1- Controls 1 Actuator- Compatiable with all controllers * Notice the type of controller- Easily portable with attached magnet- Standard cable length: coil 600mm; total 1100mm
A99LE18-1107 65
Y-CABLE
LAPY - 1 - G - ESpecial models according toClient’s requirement
NoneE=Ignore this part of the serial number if not available
Color B: BlackG: Gray
Cable 1: Coil cable2: Straight cable
Model of Y extension cable
• Ordering Information
•Features of the Y-Cable- Compatible with 2 keypads independent input.
Plug
Socket
Socket
Plug
600
250
250
500
5
84 3
2
1
67
1
2
3
84 5
6
7
17.5 (1)
5
84 3
2
67
PlugPlug
1
Socket
8
3
21
4 56
7
Socket
800
500
Options for each Actuator Type1 8 .
A99LE18-110766
Options for each Actuator Type1 8 .Function
SeriesIP54 IP65 IP66
Back fixture
turn 90°
Gear boxmaterial
S45C
Rod end with flat
connector
Safetynut
Spline(push only)
Quickrelease
Internal limit
switches
External limit
switches
Hall SensorPotentiometer
Optical Sensor
NPN TTL NPN PNP TTL
LAM
LAM-1
LAM-2
LAM-1A
LAM-2A
LAM3
LAM3-1
LAM3-2
LAM3-3
LAM3-4
LASLAS1-1
LAS1-2
LAS3LAS3-1
LAS3-2
LAS4LAS4-1
LAS4-2
LAN1
LAN1-1
LAN1-2
LAN1-3
LAN1-4
LAN2
LAN2-1A
LAN2-2A
LAN2-3A
LAN3
LAN3-1
LAN3-2
LAN3-3
LAN4
LAN4-1
LAN4-2
LAN4-3
LAN4-4
LAN5
LAN5-1
LAN5-2
LAN5-3
LAN5-4
LAC3 LAC3-1
” ” Standard” ” Option is available.” ” ” ” Only 1 option is available.
A99LE18-1107 67
HIWIN CustomerRequirements (LA)19.
*Required NO:
Customer Application
Tel: Fax:
Contact person Executive
Actuator Controller*Voltage VDC (V) *Input voltage (V) AC V or DC V
*Max. current (A) *Control axis no.
*Max. thrust force (N) *Battery YES NO
*Max. pulling force (N) *Power cord type US UK EU other
*Max.holding force (N) *Over load protection YES NO
*Stroke (mm) *IP Class
*Install length (mm) Output power (VA)
*Speed (mm/s)No load Power cord lengthFull load Removable Power cord YES NO
*Load (N) Duty cycle
*IP Class Operation temp. (�C)
No-Load current (A) Outdoor use YES NO
Duty cycle With HIWIN’s Actuator YES (Model) NO
Operation temp. (�C) Custom program YES NO
Outdoor use YES NO Housing color BLACK GRAY
Direction H. V. Expected price
Bending moment YES NO Quantity (year/month)
With HIWIN’s L/S YES NO KeypadWith HIWIN’s Controller YES (Model) NO *Control axis no.
With customer’s L/S YES NO *Custom mask YES NO
Over current YES NO *Lock function YES NO
Position feedback YES NO *With HIWIN’s Controller YES (Model) NOSpecial install requirement (Fixture, Space...etc.)
Housing color BLACK GRAY
Expected price Key mode Membrane Rubber
Quantity (year/month) Expected price
Quantity (year/month)*Other function / requirement:
(The following fills in by HIWIN Engineer)Recommend Specification:
Engineer: Manager:
FME014-02
©2011 FORM A99LE18-1107(PRINTED IN TAIWAN)
HIWIN MIKROSYSTEM CORP.No.7, Jingke Rd., Nantun District, Taichung City 40852, TaiwanTel : +886-4-23550110Fax: +886-4-23550123www.hiwinmikro.com.twbusiness@mail.hiwinmikro.com.tw
HIWIN USA•CHICAGO1400 Madeline LaneElgin, IL 60124, U.S.A. Tel : +1-847-8272270Fax: +1-847-8272291www.hiwin.cominfo@hiwin.com•SILICON VALLEYTel : +1-510-4380871Fax: +1-510-4380873
HIWIN JAPAN•KOBE3F. Sannomiya-Chuo Bldg.4-2-20 Goko-Dori. Chuo-KuKOBE 651-0087, JAPANTel: +81-78-2625413Fax: +81-78-2625686www.hiwin.co.jpinfo@hiwin.co.jp
HIWIN GmbHBrücklesbünd 2, D-77654Offenburg, GERMANYTel : +49-781-93278-0Fax: +49-781-93278-90 www.hiwin.dewww.hiwin.euinfo@hiwin.de
HIWIN SCHWEIZSchachenstrasse 80CH-8645 Jona, SWITZERLANDTel : +41-55-2250025Fax: +41-55-2250020www.hiwin.chinfo@hiwin.ch
HIWIN S.R.O.Kastanova 34CZ 62000 Brno, CZECH REPUBLICTel : +420-548-528238Fax: +420-548-220233www.hiwin.czinfo@hiwin.cz
HIWIN FRANCE24 ZI N 1 EST-BP 78F-61302 L’Aigle CedexTel: +33(0)233341115Fax: +33(0)233347379www.hiwin.frinfo@hiwin.fr
Mega-Fabs Motion Systems, Ltd.13 Hayetzira St. Industrial Park, P.O.Box 540, Yokneam 20692, IsraelTel: +972-4-9891050Fax: +972-4-9891080www.mega-fabs.cominfo@mega-fabs.com
Matrix Machine Tool(COVENTRY) LIMITEDA2 Earlplace Business ParkFletchamstead HighwayCoventry CV4 9XL United KingdomTel: +44(0)2476718886Fax: +44(0)2476678899www.matrix-machine.comsales@matrix-machine.com