Life Safety and EmergencyCommunications Systems
Quezon City: ( 410-1155, 929-9911 • Cebu: ( 346-5413 • Davao: ( 282-8606 • inquire@multi-linegroup.com • www.multi-linegroup.com
Intelligent Fire Alarm Control Panels
NFS2-640(E)Intelligent Addressable Fire Alarm System
NFS-320Intelligent Addressable Fire Alarm System
NFS2-3030Intelligent Addressable Fire Alarm System
SFP-5UDC / SFP-10UDCConventional Fire Alarm Control Panel5-zone, 10-zone
DVC-EMDigital Voice Command
ONYX FirstVision™Interactive Firefighters’ Display
LCD2-80Terminal Mode/ACSModeAnnunciator
eVance™Service Manager
• Up to 159 detectors and 159 modules per SLC; 318 devices per loop/636 per FACP or network node
• Standard 80-character display, 640-character large display (NCA-2), or display-less (a node on a network)
• High-speed network for up to 200 nodes
• 6.0 A switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC)
• Up to 159 detectors and 159 modules per SLC; 318 devices maximum
• Standard 80-character display
• High-speed network for up to 200 nodes
• 6.0 A power supply with four Class A/B built-in Notification Appliance Circuits (NAC)
• Full QWERTY keypad• Battery charger supports
18 – 200 AH batteries
• Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node
• Large 16 line, 640 character LCD backlit display or use display-less as a network node
• High-speed network for up to 200 nodes
• A Fire Alarm Control Panel that provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings
• Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs
• Programmable• Up to 32 minutes of
standard quality or 4 minutes of high quality digital audio storage of user-selected/created messages and tones
• 4-channel analog audio supported
• Up to 1000 audio sequences
• Message prioritization• Firefighters’ Telephone
Communications• Local paging microphone
option
• 22” LCD touch-screen
• Interfaces with ONYX® Series panels or NOTI•FIRE•NET (version 5.0 or higher)
• Compatible with standard and High Speed NOTI•FIRE•NET™
• Supports multiple gateways for large networks and campuses
• 80-character backlit Liquid Crystal Display (20 characters x 4 lines)
• Display mimics panel or NCA: - Event message - 20 characters for point label - 12 characters for extended label - Time, date and point address• Control switches for System
Acknowledge, Signal Silence Drill and System Reset
• LEDS for general off-normal events with UL 864 9th Edition Panels
• Keep track of annual inspection due dates for all fire systems
• Offer additional value to facility owners and managers
• Be proactive by receiving automatic alerts and notifications via Service Manager
• The customer’s equipment, service history and diagnostic information is available in real time
Features FeaturesFeatures Features
Features Features Features Features
Quezon City: ( 410-1155, 929-9911 • Cebu: ( 346-5413 • Davao: ( 282-8606 • inquire@multi-linegroup.com • www.multi-linegroup.com
800 SeriesLow-Profile Plug-inSmoke/Heat Detectors
FSM500KManual Call Point
LPX-751Very IntelligentEarly Warning (VIEW®)LASER Smoke Detector
FAPT-851Acclimate Plus™Multi-SensorLow-ProfileIntelligent Detector
NBG-12 SeriesManual Pull Stations
FSP-851(A) SeriesIntelligent Plug-InPhotoelectricSmoke Detectors withFlashScan®
• 2-wire conventional profile plug-in detectors aimed to meet the performance criteria designated by UL
• Operating Temperature Range: 0~38°C (32°F to 100°F) for Heat, 0~49°C (32°F to 120°F) for Photoelectronic
• Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
• interruptionSensitivity: 63°C (145.4°F) Fixed (Heat only)
• Operating Voltage: 8.5~30 VDC for Heat, 8.5~35 VDC for Photoelectronic
• CSIRO Approved• Two wire connection for
easy installation• Suitable for flush mounting
or surface mounting• Simple rotary decade
setting• Integral LED controlled
from panel
• Very Intelligent Early Warning (VIEW®) smoke detection
• Advanced laser light source and patented optical design
• Sleek low-profile housing (1.66”/42.164 mm height)
• NOTIFIER Analog Addressable communications protocol provides extremely reliable operation proven in millions of worldwide detector installations
• Sensitivity to 0.03%/foot
• Automatically adjusts sensitivity levels without the need for operator intervention or programming, sensitivity increases with heat
• Microprocessor-based, combination photo and thermal technology
• Addressable-analog communication• Rotary, decimal addressing (1 – 99
on current classic systems, 1 – 159 on ONYX® Series FlashScan® systems, 1 – 99 on the AFC-600)
• Addresses can be viewed and changed without the need for electronic programmers
• Dual bi-color LED design provides 360° viewing angle
• LEDs lock red when in Alarm. In FlashScan®, LEDs flash green in Standby for normal condition
• Built-in tamper-resistant feature• Sealed against back pressure
• non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal
• This series includes both single-action and dual-action models equipped with either a hex or key lock / reset
• photoelectric detector’s unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP-851T(A)
• Sleek, low-profile design
• Addressable-analog communication
• Stable communication technique with noise immunity
• Two-wire SLC connection
Features
Features
FeaturesFeatures
Features
Features
882 Photoelectronic Detector
885 Heat Detector
FSP-851(A) in B210LP(A) Base
Fire Alarm Devices
Kobishi MBA-6Fire Alarm Bells
• DC 12.1mA• FWR 12.4mA• UL 83dB• Typical 87dB• Can used at outdoor• Very low current
consumption only 12.1mA at 24VDC
Features
EXITPOINTDirectional Sounder
• Four field-selectable routing evacuation patterns
• Ideal in unfamiliar surroundings or poor visibility
• Works in open areas, corridors or stairs
• Reduces evacuation times by as much as 75%
Features
Quezon City: ( 410-1155, 929-9911 • Cebu: ( 346-5413 • Davao: ( 282-8606 • inquire@multi-linegroup.com • www.multi-linegroup.com
FMM-1(A)Monitor Module with FlashScan®
FCM-1(A)Control and Relay Module
Portable Fireman’sTelephone Handset
Telephone Receptacles
FRM-1(A)Control and Relay Module
D42404-Wire PhotoelectricDuct Smoke Detector
• Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors
• Typically mounts to a 4” [10.16 cm] square box
• Addressable Control Module provides Notifier intelligent fire alarm control panels a circuit for Notification Appliances (horns, strobes, speakers, etc.)
• Addressable Relay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, dampers, control equipment, etc.
• Allows the dry contact to be activated, either manually or through panel programming, on a select basis
• Photoelectric, integrated low-flow technology
• Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m.s to 20.32 m/sec)
• Versatile mounting options square or rectangular configuration
• Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 90% non-condensing)
Features
Features
Features
Features
FMM-1(A) (Type H)
Fire Alarm Devices
Fire Alarm Modules
800 900 SeriesLinear Heat Detector
SpectrAlertIndoor Selectable-Output Speaker Strobes and Dual VoltageEvacuation Speakers
• Multiple alarm temperature ratings available for both digital and analogue type
• Maximum zone length (Digital) - 1000 meters
• Maximum zone length (Analogue) – 600 meters
• Resettable temperature up to 120°C (248°F)(Analogue)
• Compatible with any conventional or intelligent fire alarm panel
• Plug-in design and protective cover reduce ground faults
• Universal mounting plate with an onboard shorting spring tests wiring continuity before installation
• Field selectable candela settings
• Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela
• Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts)
Features
Features
800 Series 900 Series
SpectrAlertAdvance SeriesIndoor Selectable-Output Horns, Strobesand Horn Strobes for Wall Applications
• Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela
• Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185
• Rotary switch for horn tone and three volume selections
• Universal mounting plate for wall units
Features
Recommended