LED · AC Direct Line Voltage. ... • Full Brightness with Instant On and Instant Restrike ......

Preview:

Citation preview

• EasyInstallation&Retrofitting:SimplyBypassBallastandPlug-in.Runson ACDirectLineVoltage.EliminatesCompatibility,PowerLoss&Lifetime IssuesandMaintenanceCostsassociatedwithBallasts

• FullBrightnesswithInstantOnandInstantRestrike

• OptimalDesignforHorizontalorVerticalMountSockets

• >80CRIforGreatVisibility

• SuitableforDryorDampLocation

• LowPowerConsumption

• UniversalVoltage:100-277V,AC

• Heat&ImpactResistant,UVProtected,Non-Yellowing,OpticalGradeLens

• ExcellentHeatDissipationwithProprietary-DesignedHeatSink

• CoolOperation:DoesnotaddtoHeatLoad(upto90%lessheatthan Incandescent)whileproducingBrilliantlyBrightLight

• Non-Combustible.MadefromFlameRetardant,EngineeredPolymer, theBaseisMechanicallyStrongandHeat-Resistantupto435°F(225°C)

• SafeandReliable:IsolatedCircuitDesign

• Maintenance-FreeOperation:Lastsupto50timeslongerthan IncandescentBulb.LowersCostsbyReducingRelampFrequency

•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements. FacilitatesLEED®points

•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)

•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable

• 5YearLimitedWarranty

Page:1of2

HighPerformance8WLEDPLLamp

MercuryFree

IdealforHigh-qualityIlluminationin:

• DownLights • WallScones • Bollards • WallPacks

• DecorativeLighting • AccentLighting • CeilingLights • TaskLighting

• PedestrianTunnels • PendantLights • WalkwayLighting

• StairwellLighting • CorridorLighting • CarriageLanterns

IncreasedSustainability

Up to50,000Hours

Longer Life

Reduction ofup to 87%

Energy Costs

Radiation-FreeNo Humming

IRUV

No IR/UV

No Noise

LM-80 TestedISTMT Tested

Reliability

Vibration andShock Resistant

Solid State

120 LpWLM-79 Tested

Lumen Efficacy

Reliable andLong-Lasting

Warranty

5years

LowConsumption

Power

Zero Interference

No EMi / RFi

Wide andUniform

Beam Angle

120°

PLUG-iN LAMP TM

LED

Lampcanbeorientedinanyposition-doesnotaffectordiminishthelifeofthelamp

Universal Burning Positioning

BaseDown

BaseSideways

BaseUp

G24d G24q Gx24d Gx24q

G24d-1 G24q-1 Gx24d-2 Gx24q-1 G24d-2 G24q-2 Gx24d-3 Gx24q-2 G24d-3 G24q-3 Gx24q-3 Gx24q-4

HyLiteLEDPLlampsofferatrulyuniversalG24base-designedtoreplaceboth2-pinand4-pinG24baseslisted:

NOLEAD, MERCURY, HEAVY METALS

OR TOXIC GASES

98%RECYCLABLE

1.75”

(45m

m)

0.6”

(15m

m)

5.75

" (14

5mm

)

1.4” (35mm)

8WHL-G24-8W

Incandescent Halogen CFL HyLite

60W 45W 18W / 26W 8W

87% 82% 56%-69% Energy Savings (%)

Replacewith 8W

HL-G24-8W

TheHyLiteHighPerformanceLEDPLLampisanidealEnergy-EfficientreplacementforCFLandIncandescentBulbinstallationsinExistingandNewFixtures.The8WLEDPLLampprovidesEnergy-EfficientIlluminationataWideBeamAngleof120°andreplaces18W/26WCFLBulbs,effectivelyreducingEnergyConsumptionby56%-69%andasmuchas87%whenreplacing60WIncandescentBulbs.HyLiteLEDPLLampsareratedatupto50,000hoursofLampLife.Thisis50timeslongerthanatraditionalIncandescentBulb,and7timeslongerthanaCFLBulb.ThissignificantlyreducesEnergyUsageandCostsaswellasMaintenanceExpenditures.

AC Direct Type B

350° Rotatable Base for

Directional Lighting

E361357

18W / 26WCFL Equivalent

Page:2of2

Warning - Risk of Fire or Electric Shock

• ForuseinDryorDampLocations.DonotusewheredirectlyexposedtoLiquid,Vapor,RainorWeather.Non-Submergible(notwatertight).

•OperateinFixturesthatprovidethefreeflowofairaroundtheLamp.ThiswillensureLumenMaintenanceandExtendItsWorkingLife.WhenProductsareusedin OutdoorFixtures,ensurethespaceisWaterproofandWell-Ventilated.

• TheInstallermustdetermineandverifywhether120Vto277VACisbeingutilizedattheLuminairebeforeInstallation.ImproperVoltagematchingcanresultin PerformanceDegradationand/orPhysicalDamage.TheseLampsworkonLineVoltageandrequireallBallastsandStarterstobeBypassed.

•WiringmodificationforHyLiteLEDLampInstallationrequiresknowledgeofLuminaireElectricalSystems.Ifnotqualified,DONOTattemptInstallation.ContactaQualified Electrician.

• LuminaireWiring,Ballast,orotherElectricalPartsmaybeDamagedwhenInstalling.AlwayscheckforenclosedWiringandComponents.

• TopreventWiringDamageorAbrasion,DONOTexposeWiringtoedgesofSheetMetalorotherSharpObjects.

• DONOTMakeorAlteranyOpenHolesinanEnclosureforWiringorElectricalComponentsduringInstallation.

•DONOTBlockLightemanatingfromProductinWholeorPart,asthismayCauseanUnsafeCondition.

• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandotherPowerFluctuations.

• TheEndRetrofitFixture,onceModified,canNoLongerOperateaswasOriginallyIntended.

• Efficacy:120LpW • CRI:>80 • BeamAngle:120º •Max.THD(%):<10% • UniversalInputVoltage•PowerFactor:>0.9 • Protection:IP20 •RatedLife:50,000Hrs.* •Warranty:5Years 100~277V,AC50/60Hz.•AmbientWorkingTemperature:-4ºF~+104ºF(-20ºC~+40ºC) • BaseType:G24•CCT:3500K(NeutralWhite)and4000K(CoolWhite)* Depending upon the ambient temperature of the installation location

Model Delivered InputLine Dimensions&Weight(each) No. Watts Lumens Current Width Height NetWeight

HL-G24-8W 8 893~920 64mA@120V 1.4”(35mm) 5.75”(145mm) 3.4oz.(95g)

HyLite PL Lamp, HL-G24-8W

Photometrics

Intensity: (Unit, cd)

Note: The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance

1 m3.3 ft.

Height

2 m6.5 ft.

3 m9.8 ft.

4 m13.1 ft.

5 m16.4 ft.

Angle: 113.60° DiameterCenter E (lx/fc)

3.06 m10 ft.

6.11 m20 ft.

9.16 m30 ft.

12.22 m40 ft.

15.27 m50 ft.

309.62 lx28.76 fc

77.40 lx7.19 fc

34.40 lx3.19 fc

19.35 lx1.8 fc

12.39 lx1.15 fc0

30

60

90

120

150-/+180

-150

-120

-90

-60

-30

0

62.8

125.5

188.3

251.0

313.8

Ave. E (lx/fc)

122.06 lx11.34 fc

30.52 lx2.84 fc

13.56 lx1.26 fc

7.63 lx0.71 fc

4.88 lx0.45 fc

IlluminanceDistance Curve

Angle [50% Max.] [10% Max]C180/360 113.6° 168.5°C0/180 113.6° 168.5°C90/270 107.1° 154.1°

OrderingforHyLite8WLEDPLLampwithG24Base

Model Suffix (CCT,ºK)

HL-G24-8W -35K 3500K=NeutralWhite(NW) -40K 4000K=CoolWhite(CW)

PLUG-iN LAMP TM

LED

Warning: Disable all Power to the Luminaire. HyLite LED PL LampsareDesignedtoworkoff100V~277V,AC.HyLite8WLEDPLLampsarenotCompatiblewithElectronicBallasts.ElectronicBallast(ifequipped)mustbeBypassedor removed from theLuminairebefore installingtheLamp.FailuretoFollowInstructionswillVOIDWarranty.Itcanalsoresult in an Electric Shock, or Fire.NOT FOR TOTALLY ENCLOSEDLUMINAIRESOREMERGENCYLIGHTING.NOTFORUSEWITHDIMMERS.

As part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.

AC Direct Type B

©2015-2018HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:www.HyLiteLEDLighting.Com 031618