4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

KEY RESIN COMPANY STANDARD FLOORING DESIGN DETAILS GUIDE

TABLE OF CONTENTS – P. 1

VAPOR BARRIER FOR SLAB ON GRADE KEY-DTL-1 CONTRACTION/CONTROL JOINT KEY-DTL-2 EXPANSION/ISOLATION JOINT KEY-DTL-3 CONSTRUCTION/COLD JOINT KEY-DTL-4 BURIED CONTROL JOINT/CRACK TREATMENT KEY-DTL-5 EPOXY TERRAZZO TO CARPET/VCT TERMINATION KEY-DTL-6 EPOXY FLOORING KEY-IN TERMINATION KEY-DTL-7 EPOXY FLOORING STEPS OVER CONCRETE KEY-DTL-8 EPOXY FLOORING OVER CEMENT/EPOXY FILL KEY-DTL-9 FLANGED DRAIN DETAIL KEY-DTL-10 TRENCH DETAIL KEY-DTL-11 COVE DETAIL #1 KEY-DTL-12

COVE DETAIL #2 KEY-DTL-13 COVE DETAIL #3 KEY-DTL-14

9/04/12 KEY RESIN FLOORING DETAIL DWGS

Click above to link directly to the design detail of your choice.

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

KEY RESIN COMPANY STANDARD FLOORING DESIGN DETAILS GUIDE

TABLE OF CONTENTS – P. 2

COVE DETAIL #4 KEY-DTL-15

6/29/11 KEY RESIN FLOORING DETAIL DWGS

Click above to link directly to the design detail of your choice.

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

VAPOR BARRIER FOR SLAB ON GRADE

6/29/11

EXTERIOR WALL

NOTE: DO NOT PLACE 2” OF SAND OVER VAPOR BARRIER REFERENCE ACI-302.IR-04

3/8” KEY EPOXY TERRAZZO OR OTHER RESIN FLOOR SYSTEM

CONCRETE SLAB

MOISTURE VAPOR BARRIER (10-20 MIL REINFORCED SUGGESTED) OR AS PER NTMA SPECIFICATIONS

COMPACTED BASE

NOTE: CONCRETE FLOOR SLAB SHOULD BE ABOVE SOIL ELEVATION

NOT TO SCALE

KEY-DTL-1

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

STANDARD DIVIDER STRIP

PREFERRED

JOINT DETAILS

KEY EPOXY FLOORING

ALTERNATE

NOT TO SCALE

CONTRACTION/ CONTROL JOINT

CONCRETE SLAB

10/28/10 KEY-DTL-2

KEY #780 FLEXIBLE EPOXY

EPOXY ADHESIVE FULL LENGTH OF STRIP

NOTE 1: THIS DETAIL MUST BE USED FOR RADIANT HEATED FLOORS. OPTION: FOR “ART WORK AREAS,” SEE BURIED CONTRACTION JOINT DETAIL. REFER TO DETAIL # KEY-DTL-5

FILL SAW CUT JOINT WITH KEY CRACK FILLER #715

(OR APPROVED 100% SOLIDS RIGID EPOXY)

FILL SAW CUT JOINT WITH KEY CRACK FILLER #715 (OR APPROVED 100% SOLIDS RIGID EPOXY)

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

JOINT DETAILS NOT TO SCALE

KEY-DTL-3 01/04/10

EXPANSION / ISOLATION JOINT

URETHANE SEALANT BETWEEN TWO DIVIDER STRIPS

COMPRESSIBLE BACKER ROD FILLER

KEY EPOXY FLOORING

EPOXY ADHESIVE FULL LENGTH OF STRIP

CONCRETE SLAB

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

JOINT DETAILS NOT TO SCALE

KEY-DTL-4 01/04/10

CONSTRUCTION / COLD JOINT (Next Day Pour Where Joint Has Eased

Shoulders or Has Opened)

STANDARD DIVIDER STRIP *

DOWEL IN ACCORDANCE WITH ACI 302 OR ENGINEER OF RECORD TO PREVENT VERTICAL MOVEMENT.

KEY EPOXY FLOORING

CONCRETE SLAB

KEY #780 FLEXIBLE EPOXY

EPOXY ADHESIVE FULL LENGTH OF STRIP

* IF CONSTRUCTION/COLD JOINT HAS NOT OPENED, STRIPS MAY BE SET BACK TO BACK

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

NOT TO SCALE

STR

UC

T. S

LAB

KEY ELASTOMERIC MEMBRANE #580

2’ WIDE X 30-35 MILS THICK

3/8” KEY EPOXY TERRAZZO OR RESIN FLOOR SYSTEM

FILL SAW CUT JOINT WITH KEY CRACK FILLER #715 (OR

APPROVED 100% SOLIDS RIGID EPOXY)

BURIED CONTROL JOINT/CRACK TREATMENT

OPTIONAL FIBERGLASS FABRIC REINFORCEMENT

ADHERED TO SURFACE, NOT IMBEDDED FULL DEPTH

NOTE: METHOD MAY ALSO BE USED TO TREAT CRACKS LARGER THAN 1/32” WIDTH

KEY-DTL-5 10/28/09

TREATMENT OF CONTRACTION JOINTS (SAWCUTS) AND CRACKS IS DONE IN ANTICIPATION OF HORIZONTAL MOVEMENT

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

STR

UC

T. S

LAB

EPOXY TERRAZZO, CARPET TERMINATION

METAL DIVIDER STRIP

VCT, CARPET, OR SHEET GOODS

FILL PROVIDED BY VCT, CARPET, OR

SHEET GOODS CONTRACTOR

NOTE: EPOXY TERRAZZO TO BE POURED FIRST. OTHER TRADES TO FINISH AT PROPER ELEVATION

3/8” KEY EPOXY TERRAZZO

NOT TO SCALE

2/24/08 KEY-DTL-6

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

STR

UC

T. S

LAB

EPOXY FLOORING KEY-IN TERMINATION NOT TO SCALE

KEY RESIN FLOORING

SAW-CUT EDGE

2/24/08 KEY-DTL-7

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

EPOXY TERRAZZO OVER CONCRETE

CONCRETE SUBSTRATE

KEY RESIN #502 PRIMER OR KEY RESIN MOISTURE VAPOR TREATMENT

KEY RESIN #580 FLEXIBLE EPOXY CRACK ISOLATION MEMBRANE (AS NEEDED)

KEY RESIN EPOXY TERRAZZO SYSTEM

NOT TO SCALE

9/04/12 KEY-DTL-8

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

APPROVED CEMENT UNDERLAYMENT OR EPOXY FILL

KEY RESIN #502 PRIMER OR KEY RESIN MOISTURE VAPOR TREATMENT

KEY RESIN #580 FLEXIBLE EPOXY CRACK ISOLATION MEMBRANE (AS NEEDED)

KEY RESIN FLOORING

NOT TO SCALE

9/04/12

Click For Table of Contents

KEY-DTL-9

EPOXY FLOORING OVER EPOXY/CEMENT FILL

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

FLANGED DRAIN DETAIL

SLOPE TO DRAIN

KEY RESIN FLOOR SYSTEM

WEEP HOLES

NOTE: BE SURE WEEP HOLES ARE NOT PLUGGED BY MORTAR OR MEMBRANE

CHEMICAL RESISTANT FLANGED DRAIN

DRAIN 1/8” MIN. BELOW TOP OF TOPPING

NOT TO SCALE

CONCRETE SLAB

2/24/08 KEY-DTL-10

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

TRENCH DETAIL NOT TO SCALE

CHEMICAL RESISTANT ANGLE TO HOLD TRENCH GRADING

• STAINLESS STEEL • PROTRUDED VINL ESTER OR POLYESTER • PVC CHEMICAL RESISTANT

MONOLITHIC RESIN FLOORING

CHEMICAL RESISTANT MONOLITHIC RESIN TRENCH LINING SYSTEM

KEYED EDGES ANCHOR TO THE SUBSTRATE

NOTE: TRENCH LINING AND FLOORING SYSTEM MUST “KEY” INTO THE TRENCH GRADING

CONCRETE SLAB

2/24/08 KEY-DTL-11

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

COVE DETAIL #1 NOT TO SCALE

STANDARD DIVIDER STRIP

RADIUS OR CHAMFER

1/4” TO 3/8” EPOXY FLOORING & BASE WITH 1” RADIUS

CRACK ISOLATION MEMBRANE (FLEXIBLE EPOXY ONLY)

GROUT TOP AS REQ’D

CONCRETE SLAB

WAL

L SU

BSTR

ATE

4” T

O 1

2”

2/24/08 KEY-DTL-12

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

COVE DETAIL #2 NOT TO SCALE

RADIUS OR CHAMFER

CRACK ISOLATION MEMBRANE (FLEXIBLE EPOXY ONLY)

GROUT TOP AS REQ’D

CONCRETE SLAB

WAL

L SU

BSTR

ATE

4” T

O 1

2”

2/24/08

GROUT TOP AS REQ’D

KEY-DTL-13

Click For Table of Contents

1/4” TO 3/8” EPOXY FLOORING & BASE

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

COVE DETAIL #3 NOT TO SCALE

1/8” TO 1/4” EPOXY FLOORING & BASE WITH 3/4” RADIUS

COVE CAP STRIP OPTIONAL

CONCRETE SLAB

WAL

L SU

BSTR

ATE

4” T

O 6

1/7/11 KEY-DTL-14

Click For Table of Contents

4050 Clough Woods Drive Batavia, Ohio 45103

888-943-4532 www.keyresin.com

DETAIL:

DATE: FILE #:

COVE DETAIL #4 NOT TO SCALE

1/8” TO 3/8” EPOXY FLOORING & BASE WITH 3/4”-1” RADIUS

COVE CAP STRIP OPTIONAL

CONCRETE SLAB

WAL

L SU

BSTR

ATE

4” T

O 8

6/29/11 KEY-DTL-15

Click For Table of Contents

STANDARD DIVIDER STRIP

Recommended