View
216
Download
0
Category
Preview:
Citation preview
3401 East Jefferson Avenue • Detroit, MI 48207-4232313-259-6400 • FAX 313-259-3121 • info@kirlinlighting.com • www.kirlinlighting.com
MRS-17600 System Features:• Two light recessed, adjustable LDRP LED lighting system with dual
controls, delivers high CRI, deep cavity (60º angle) illumination.
• Full control of lighting system (direction, intensity, power) from both remote and wall controls. Light beams may be directed to 2 sites or superimposed on one target.
• Tactile membrane controls feature invisible and safe infrared signals.
• MRS-17600 delivers up to 6000 fc with full range dimming to 10%.
• Recessed, inconspicuous fixtures with BioGard™ antimicrobial trims are easy to disinfect, providing a safe and clean environment.
• Kirlin’s exclusive three year limited warranty (one year remote control).
Piedmont Fayette Hospital, Fayetteville, GA MRS-17600 Shown
INFRALED® 60: LED Birthing Suite Lighting
02/17
→
Low CRI & Low R9COMPETITION
High CRI & High R9KIRLIN
OPTeCOLOR™ High CRI is only part of the color rendering story. CRI only measures a light source’s ability to render pastel colors, excluding important saturated colors like red (R9). High R9 values are critical for accurate patient diagnosis and treatment. KIRLIN OPTeCOLOR™ LEDs deliver both ultra-high CRI (95+) and R9 (85) lighting.
3401 East Jefferson Avenue • Detroit, MI 48207-4232313-259-6400 • FAX 313-259-3121 • info@kirlinlighting.com • www.kirlinlighting.com
233/4” [603mm]
183/8” [467mm]
22” sq [559mm]
111/4”[286mm]
60°
Fully recessed fixtures are unobtrusive and inconspicuous, providing a safe and open work space for staff and a home-like atmosphere for patients. BioGard™ antimicrobial smooth trims are easy to clean and disinfect.
Full control of lighting system (direction, intensity, power) from both remote and wall controls, using invisible and safe infrared signals. Impact resistant design protects remote from common mishaps. Smooth tactile membrane switches do not trap pathogens and are easy to clean and disinfect. Loss deterring beeper reminds staff to return remote to wall control “home”.
Four OPTeCOLOR™ LED light heads per motorized lighting system deliver up to 6000 fc with no heat in the beam. Redundancy of controls, electronic components and circuitry ensures illumination at all times.
Typical Side View
LOW VOLTAGE CABLE35’ [1067cm]
3.5’ [107cm]
WALL CONTROL& BACK BOX
LUMINAIRE(ONE SHOWN)
SITE
3’ [91cm]
8’ [244cm]
7’[213cm]
TASKHEIGHT
CEILINGHEIGHT
ANGLE of ILLUMINATION
SETBACK
Recommended Fixture Setback / Locationwith Angle of Illumination and Light Levels
(Task Height: 3’ - Spacing Between Lights: 4’)
CeilingHeight
Setbackfrom
Break in Bed
Angle of
Illumination
Footcandles on
Task
8’7.0’ Optimal 54.5 5105
6.0’ Alternative 50.2 6052
8.5’8.0’ Optimal 55.5 4080
7.0’ Alternative 51.8 4851
9’8.0’ Optimal 53.1 3850
7.0’ Alternative 49.4 4515
9.5’9.0’ Optimal 54.2 3163
8.0’ Alternative 50.9 3622
10’ 9.0’ Optimal 52.1 2997
For additional setback locations, please consult factory.
BioGard™
INFRALED® 60: Birthing Suite LightingFor more information, including specification sheets, photometry and owner’s manuals on these and other Kirlin products,
please visit www.kirlinlighting.com or call your local Kirlin Sales Representative for catalogs.
OPTeCOLOR™ LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, red tissues and skin tones. 60,000 hour long life (L70) dramatically reduces maintenance frequency and cost.
MRS-17600 Lighting System
Recommended