Indoor module NIBE™ EVP 500Designed for houses / properties with waterborne heating
NIBE EVP 500
The indoor module consists of a pressure vessel, two immer-sion heaters, docking pump and intelligent control, and is optimally adapted to suit docking with NIBE’s air/water heat pumps. The total boiler water volume is 500 litres.
Hot water heating occurs via a cam pipe coil. The low inter-nal volume and high circulation rate of the water in the coil prevents bacterial growth. In the event of a domestic water flow greater than 12 l/min, supplementing with a core wa-ter heater is recommended.
The immersion heaters have a max output of 18 kW wit-hoption of setting lower outputs. The supplied output is 9 kW.
Features of NIBE™ EVP 500
Very easy to install and use
Optimally adapted to suit docking with NIBE air/water heat pumps
Suitable for heat pump sizes: 8, 10, 14 kW
Intelligent control
Connection for additional heat source, e.g. solar
NIBE Energy Systems Box 14, SE-285 21 Markaryd. www.nibe.eu
NIBE makes reservations for any factual or printing errors in this brochure. ©NIBE 2010.
Technical specificationsNIBE™ EVP 500
M10553 KIF GB EVP 500 1021-2
Type NIBE EVP 500
Height (excl. foot: 20 – 55 mm) mm 1810 (1760*)
Required ceiling height mm 1 870
Width mm 750 (670*)
Depth mm 950 (905*)
Weight kg 200
Volume total litres 500
Volume of vessel litres 495
Volume loop litres 3
Supply voltage 400 V 3 NAC 50Hz
Rated output charge pump W 90
Maximum heat pump output** kW 15
Output immersion heater kW 18 (output on delivery 9)
Enclosure class IP 21
Cut-off pressure, loop 0.9 MPa (9 bar)
Max permitted pressure in boiler 0.3 MPa (3 bar)
F20XX EVP 500
RC
UG**
SF* LP TV
PG
DG
FG
SV
SÄV2*SÄV1*
EXP*
BL*
CP*
F20XX EVP 500
RC
UG**
SF* AV*
AV*
AV*
AV*
LP TV
BV**
PG
DG
FG
SV
SÄV2*
SÄV1*
EXP*
BL*
CP*
SÄV3*
VP1
EVP 500
RC
BV**
SÄV3*
63
76
44
52
44 49
15
52
85 35
52 45
99
Abbreviations
OFF* Shut-off valveBL* Mixer valveCP* Circulation pumpDG Docking sensorEXP* Expansion vesselFG Temperature sensor, flow linePG Boiler sensorRC Control boxSV Shunt valveSÄV1* Safety valve, boilerSÄV2* Safety valve, water heaterSÄV3* Safety valve, heat pumpTV Drain valveOS** Temperature sensor, outdoorBV** Non-return valveSN Charge pumpSF* Particle filter
System description
The indoor module and heat pump work optimally towards a heat distribution system of up to 55/45 °C at dimensio-ned outdoor temperature. At higher flow line temperatures (maximum 65 °C) heat pump operation can be limited. If the heat pump operation is limited the installation only works with the addition. The heat pump starts when temperatures permit operation again. For further information about system limitation, see the heat pump manual.
DockingNIBE EVP 500 can be installed in several different ways. The requisite safety equipment must be installed in accordance with current regula-tions for all docked options. See www.nibe.eu for docking options.
EVP 500 must be docked to an outdoor air heat pump with a maxi-mum output of 15 kW.Pipe connection to NIBE outdoor air heat pump Connect the heat pump’s supply (70) to the EVP’s ”Supply HP.” (76). The heat pump’s return line (71) must be connected to the EVP’s ”Return line HP” (75). The heat pump’s supplied particle filter must be installed on the heat pump’s return line.
* Measured without insulation and covers** Applies to outdoor air heat pump at 7/45 °C (Outdoor temperature / Supply temperature)
Recommended