etallic Rigid Conduit Fittings and AccessoriesIn This Section…
Steel City ® FittingsOverview .........................................................................F-2–F-3
Thinwall Conduit Fittings (EMT)........................................F-4–F-9
Rigid/Intermediate Grade Conduit Fittings .......................F-10–17
Flexible Cord and Power Cable Connectors ...........................F-18
Liquidtight Flexible Metal Conduit and Connectors.......F-19–F-23
Non-Metallic Sheathed Cable Fittings ..........................F-24–F-25
Armored Cable/Flexible Metallic Conduit Fittings..........F-26–F-31
Service Caps.........................................................................F-31
Cable Caps, Protector, Straps and Clips; Threaded Rod and Coupling ..................................................F-32
Beam Clamps........................................................................F-33
Ground Clamps, Pipe Hangers ...............................................F-34
Carlon® Non-Metallic Rigid Conduit Fittings and Accessories
PVC Conduit Repair System .........................................F-35–F-36
Schedule 40 & 80 Elbows............................................F-37–F-42
Schedule 40 & 80 Fittings & Accessories.....................F-43–F-46
Conduit Bodies & Accessories......................................F-47–F-48
Junction Boxes ............................................................F-49–F-50
Switch Boxes...............................................................F-51–F-53
Support Straps ......................................................................F-54
Conduit Clamps ...........................................................F-55–F-56
Schedule 40 & 80 Tech Specs...............................................F-57
Utility Conduit ..............................................................F-58–F-59
P&C Duct.....................................................................F-60–F-68
Telephone Duct............................................................F-69–F-71
Split Duct ..............................................................................F-72
Accessories
PVC Cements and Sealers.......................................F-73–F-77
PVC Conduit Cutters .........................................................F-78
EZ Bend™ .........................................................................F-79
Rope & Tape.....................................................................F-80
Spacers .......................................................................F-81–F-86
P&C Flex™....................................................................F-87–F-92
F-1
Overview
Fitti
ngs
Couplings and Connectors
Superior Quality and Design• Strict tolerances throughout fitting
ensures a straight conduit run with no sagging over extreme lengths
• Chamfered entry provides lead-in for conduit insertion
Dependable Pipe Stop• 360° groove traveling the circumference
ensures that conduit forcefully insertedwon’t break through to the opposite side of the fitting. Also, it does not exceedthickness of EMT and prevents interferencewith pulling conductors
Extra-Large Head Tri-Drive Set Screw • Accommodates Phillips, slotted
and square drives
Enhanced Locknut Construction• Heavy-duty turned sharp teeth,
double-threaded
Advantages of Steel City® Commercial Conduit Fittings
Steel City® Conduit Fittings provide long-lasting service in commercial,industrial and residential construction. Our fittings are manufacturedwithin strict tolerances to maintain consistent performance. Installers can be assured that every fitting with the Steel City® name will work every time. So when you select Steel City® Conduit Fittings, that meansfewer headaches and call-backs.
Steel City® products symbolize the highest quality standards inmanufacturing and innovative design, with one of the most completeofferings available. Contact a T&B distributor nearest you to select the right Steel City® product for your requirements.
Steel City® Fittings
Compression Fittings
Dependable Pipe Stop • Strong, thick protrusion that does not
exceed thickness of EMT. Keeps forcefullyinserted conduit from breaking throughthe opposite side of the coupling, whilenot interfering with the pulling ofconductors
Heavy-Duty Thick Steel Body/Glandswith Continuous Threading• True hexagonal shape. The non-circular
design has actual flats for gripping powerusing hand or tool force
Extra-Thick Electro-Plated Zinc Finish• Ensures corrosion resistance while the
clear chromate coating gives the fittingstheir quality shine and luster
F-2
Overview
Here’s How the Steel City® Part Number System Works
BG – Bushings, Grounding
BI – Bushings, Insulated
BL – Blanks
BR – Rigid Spacer
BS – Box Spacer
BT – Thinwall Spacer
BU – Bushings
CB – Clamp Back
CP – Cable Protector
EK – 3-Piece Coupling
FA – Fire Alarm
GA – Ground Clamp (Armored Ground Wire)
GC – Ground Clamp
H – Hub
HA – Heavywall Adapter
HC – Heavywall Connector
HK – Heavywall Coupling
HL – Heavywall Elbow
HO – Heavywall Offset
HS – Heavywall Strap
LG – Locknut, Grounding
LN – Locknut
LT – Liquidtight
NC – Non-Metallic Sheathed Cable Connector
NS – Non-Metallic Sheathed Cable Strap
RB – Reducing Bushings
RT – Raintight
SH – Service Entrance Fitting
SL – Service Ells
SR – Sealing Rings
SS – Stainless Steel
LS – Locknut, Sealing
TC – Thinwall Connectors
TK – Thinwall Couplings
TL – Thinwall Elbow
TO – Thinwall Offset
TS – Thinwall Strap
TX – Thinwall to Flexible Metallic Conduit Fitting
UC – Utility Connector
USA – Made in USA
WA – Washer
XC – Armored Cable or Flexible Metallic Conduit Connector
XK – Armored Cable or Flexible Metallic Conduit Coupling
1st Digit — Material1 = Steel2 = Die Cast3 = Combination Steel and Die Cast4 = Malleable5 = Plastic6 = Aluminum7 = Steel Insulated8 = Die Cast Insulated9 = Malleable Insulated
2nd Digit — Method1 = Compression2 = Set Screw3 = Other
3rd/4th Digit — Size0 = 3⁄8"1 = 1⁄2"2 = 3⁄4"3 = 1"4 = 11⁄4"5 = 11⁄2"6 = 2"7 = 21⁄2"8 = 3"9 = 31⁄2"10 = 4"11 = 5"12 = 6"
Easy-to-identify alphabetical prefixes:
A few examples of the three-digit identificationsystem for thinwall fittings are:
TK-111A: 1⁄2" steel, compression-type coupling
TC-714A: 11⁄4" steel insulated compression-type connector
TC-822SC: 3⁄4" die cast, insulated, set-screw type connector
Fittings
F-3
Thinwall Conduit Fittings (EMT)
F-4
Fitti
ngs
InsulatedCONDUIT INNER OUTER
“A” CAT NO. SIZE (IN.) PACK PACK
TC-721A 1⁄2 50 500TC722A 3⁄4 50 250TC-723A 1 25 100TC724A 11⁄4 — 25TC725A 11⁄2 — 25TC726A 2 — 25TC727A 21⁄2 — 10TC728A 3 — 5TC729A 31⁄2 — 5TC7210A 4 — 5TC721A-FA 1⁄2 50 500TC722A-FA 3⁄4 50 250TC723A-FA 1 25 100
CONDUIT INNER OUTER “A” CAT NO. SIZE (IN.) PACK PACK
TK121A 1⁄2 50 500TK122A 3⁄4 50 250TK123A 1 25 100TK124A 11⁄4 — 25TK125A 11⁄2 — 25TK126A 2 — 25TK127A 21⁄2 — 10
• Concrete tight when taped
• Zinc plated
• Fire Alarm (FA) painted red for fire alarm identification
Non-InsulatedCONDUIT INNER OUTER
“A” CAT NO. SIZE (IN.) PACK PACK
TC111A 1⁄2 50 500TC112A 3⁄4 50 250TC113A 1 25 100TC114A* 11⁄4 — 25TC115A* 11⁄2 — 25TC116A* 2 — 25TC117A 21⁄2 — 10TC118A 3 — 5TC119A 31⁄2 — 5TC1110A 4 — 5TC111A-RT 1⁄2 50 500TC112A-RT 3⁄4 50 250TC113A-RT 1 25 100TC114A-RT* 11⁄4 — 25TC115A-RT* 11⁄2 — 25TC116A-RT* 2 — 25TC117ART 21⁄2 — 10TC118ART 3 — 5TC119ART 31⁄2 — 5TC1110ART 4 — 5
InsulatedCONDUIT INNER OUTER
“A” CAT NO. SIZE (IN.) PACK PACK
TC711A 1⁄2 50 500TC712A 3⁄4 50 250TC713A 1 25 100TC714A 11⁄4 — 25TC715A 11⁄2 — 25TC716A 2 — 25TC717A 21⁄2 — 10TC718A 3 — 5TC719A 31⁄2 — 5TC7110A 4 — 5TC711A-RT 1⁄2 50 500TC712A-RT 3⁄4 50 250TC713A-RT 1 25 100TC714A-RT* 11⁄4 — 25TC715A-RT* 11⁄2 — 25TC716A-RT* 2 — 25TC717ART 21⁄2 — 10TC718ART 3 — 5TC719ART 31⁄2 — 5TC7110ART 4 — 5
• 1⁄2"–4" concrete tight
• Zinc plated
• RT — Raintight
UL File No. E-16592.*O-rings are supplied.
UL File No. E-16592.
Non-InsulatedCONDUIT INNER OUTER
“A” CAT NO. SIZE (IN.) PACK PACK
TC121A 1⁄2 50 500TC122A 3⁄4 50 250TC123A 1 25 100TC124A 11⁄4 — 25TC125A 11⁄2 — 25TC126A 2 — 25TC127A 21⁄2 — 10TC128A 3 — 5TC129A 31⁄2 — 5TC1210A 4 — 5TC121A-FA 1⁄2 50 500TC122A-FA 3⁄4 50 250TC123A-FA 1 25 100
UL File No. E-16592.UL File No. E-16592.
Set ScrewConnectors —Steel
CONDUIT INNER OUTER “A” CAT NO. SIZE (IN.) PACK PACK
TK128A 3 — 5TK129A 31⁄2 — 5TK1210A 4 — 5TK121A-FA 1⁄2 50 500TK122A-FA 3⁄4 50 250TK123A-FA 1 25 100
Set Screw Couplings — Steel
Steel City® Raintight EMT Compression Fittingsfeature a distinctive design and a vibrant goldgland nut, enabling inspectors to visually inspectconformance from a distance. There’s no close-up inspection required!
• Concrete tight when taped
• Zinc plated
UL File No. E-16592.
FA — Fire Alarm.UL File No. E-16592.
FA — Fire Alarm.
Compression Connectors — Steel
NOTE: A sealing ring is required when fitting is used outsideon the tops and side of enclosure.
Thinwall Conduit Fittings (EMT)
F-5
Fittings
CONDUIT INNER OUTER “A” CAT NO. SIZE (IN.) PACK PACK
TK111A 1⁄2 50 250TK112A 3⁄4 50 250TK113A 1 25 100TK114A 11⁄4 — 25TK115A 11⁄2 — 25TK116A 2 — 25TK117A 21⁄2 — 10TK118A 3 — 5TK119A 31⁄2 — 5TK1110A 4 — 5
Steel City® Raintight EMT Compression Fittingsfeature a distinctive design and a vibrant goldgland nut, enabling inspectors to visually inspectconformance from a distance. There’s no close-up inspection required!
CAT. NO. DESCRIPTION STD. CTN.
TC101-SC 1⁄2" Uninsulated 500TC-102-SC 3⁄4" Uninsulated 250TC-701-SC 1⁄2" Insulated 500TC-702-SC 3⁄4" Insulated 250UL Listing No. E16592, CSA Listing No. LR-12798.
Installation using either slotted or Phillips screwdriver head,35-in-lb of torque onto the EMT.
NOTE: Excessive torque could damage EMT or housing.
• Simple, one-piece installation with no locknuts
• Available in insulated or non-insulated throat
• Screw designed for exceptional pullout resistance
• Captive screw ensures that the screw is intact for installationand resists backing out after installation
• Corrosion-resistant, zinc-chromatic plating
• Positive grounding
• Vibration-resistant screw design
• UL listed and CSA certified
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LTT 111 1⁄2 EMT to 1⁄2 Liquidtight 13⁄4 15⁄16 11⁄8 100LTT-112 3⁄4 EMT to 3⁄4 Liquidtight 13⁄4 111⁄64 13⁄8 50LTT-113 1 EMT to 1 Liquidtight 115⁄16 11⁄2 13⁄4 25
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LTH 111 1⁄2 Rigid to 1⁄2 Liquidtight 17⁄8 11⁄8 11⁄8 100
A
CCorner
BCorner
A
CCorner
BCorner
• Steel
• Raintight
• Zinc plated
UL File No. E-16592.
CONDUIT INNER OUTER “A” CAT NO. SIZE (IN.) PACK PACK
TK111A-RT 1⁄2 50 250TK112A-RT 3⁄4 50 250TK113A-RT 1 25 100TK114A-RT 11⁄4 — 25TK115A-RT 11⁄2 — 25TK116A-RT 2 — 25TK117A-RT 21⁄2 — 10TK118A-RT 3 — 5TK119A-RT 31⁄2 — 5TK1110A-RT 4 — 5
UL File No. E-16592.
CompressionCouplings — Steel
• Steel
• Raintight
• Zinc plated
EMT LOK Conduit Connector — Steel
Combination Compression Couplings — Heavywall to Liquidtight Flexible Metal Conduit — Steel
Combination Compression Couplings — Thinwall to Liquidtight Flexible Metal Conduit — Steel
• 1⁄2"–4" concrete tight
• Zinc plated
• RT — Raintight
Thinwall Conduit Fittings (EMT)
F-6
Fitti
ngs
A
B
CONDUIT DIMENSIONS (IN.) STD. CAT NO. SIZE (IN.) A B CTN.
Non-Insulated
TC-211-SC 1⁄2 11⁄4 1 500TC-212-SC 3⁄4 111⁄32 15⁄32 250TC-213-SC 1 129⁄64 115⁄32 200TC-214-SC 11⁄4 113⁄16 127⁄32 100TC-215-SC 11⁄2 17⁄8 21⁄16 40TC-216-SC 2 25⁄32 217⁄32 20TC-217-SC 21⁄2 245⁄64 31⁄4 12TC-218-SC 3 27⁄8 315⁄16 12TC-219-SC 31⁄2 247⁄64 47⁄16 10TC-2110-SC 4 213⁄16 415⁄16 6
CONDUIT DIMENSIONS (IN.) STD. CAT NO. SIZE (IN.) A B CTN.
Insulated
TC-811-SC 1⁄2 123⁄64 63⁄64 500TC-812-SC 3⁄4 115⁄32 15⁄16 250TC-813-SC 1 135⁄64 115⁄32 200TC-814-SC 11⁄4 129⁄32 127⁄32 100TC-815-SC 11⁄2 131⁄32 21⁄16 40TC-816-SC 2 21⁄4 217⁄32 20TC-817-SC 21⁄2 225⁄32 31⁄4 12TC-818-SC 3 231⁄32 315⁄16 12TC-819-SC 31⁄2 227⁄32 47⁄16 10TC-8110-SC 4 229⁄32 415⁄16 6
• 1⁄2"–4" concrete tight
OFFSET CONDUIT DIMENSIONS (IN.) STD.CAT NO. (IN.) SIZE (IN.) A B CTN.
TO-211SC 3⁄8 1⁄2 213⁄64 1 200UL File No. E-16592.
A
B
A
B
CONDUIT DIMENSIONS (IN.) STD. CAT NO. SIZE (IN.) A B CTN.
TL-291 1⁄2 1.81 1.00 100TL-292 3⁄4 2.00 1.25 50UL File No. E-16592.
CSA File No. LR-12798.
• Concrete tight when taped
A
B
CONDUIT DIMENSIONS (IN.) STD. CAT NO. SIZE (IN.) A B CTN.
TK-211-SC 1⁄2 11⁄2 13⁄32 500TK-212-SC 3⁄4 15⁄8 15⁄16 250TK-213-SC 1 17⁄8 145⁄64 200TK-214-SC 11⁄4 113⁄16 23⁄32 100TK-215-SC 11⁄2 29⁄32 221⁄64 40TK-216-SC 2 211⁄32 229⁄32 20TK-217-SC 21⁄2 313⁄64 311⁄64 12TK-218-SC 3 37⁄32 41⁄2 12TK-219-SC 31⁄2 39⁄64 51⁄16 10TK-2110-SC 4 33⁄16 541⁄64 6UL File No. E-16592 — 1⁄2"–4".
CSA File No. LR-12798 — 1⁄2"–11⁄4", 21⁄2"–4".
• 1⁄2"–4" concrete tight
UL File No. E-16592 — 1⁄2"–4". CSA File No. LR-12798 — 1⁄2"–2".
Capped CornerCouplings —Die Cast Zinc
Compression Couplings —Die Cast Zinc
Compression Connectors — Die Cast Zinc
Offset CompressionConnectors —Die Cast Zinc
Thinwall Conduit Fittings (EMT)
F-7
Fittings
CONDUIT A (IN.) B STD.CAT NO. SIZE (IN.) TC-221 SERIES TC-821 SERIES (IN.) CTN.
Non-Insulated
TC-221-SC 1⁄2 15⁄32 117⁄64 15⁄16 500TC-222-SC 3⁄4 113⁄32 133⁄64 15⁄32 250TC-223-SC 1 19⁄16 121⁄32 127⁄64 200TC-224-SC 11⁄4 115⁄16 21⁄32 113⁄16 100TC-225-SC 11⁄2 29⁄32 23⁄8 23⁄64 40TC-226-SC 2 233⁄64 239⁄64 217⁄32 20TC-227-SC 21⁄2 33⁄16 39⁄32 319⁄64 12TC-228-SC 3 325⁄64 331⁄64 41⁄16 12TC-229-SC 31⁄2 331⁄64 319⁄32 417⁄32 10TC-2210-SC 4 347⁄64 353⁄64 51⁄16 6
CONDUIT A (IN.) B STD.CAT. NO. SIZE (IN.) TC-221 SERIES TC-821 SERIES (IN.) CTN.
Insulated
TC-821-SC 1⁄2 15⁄32 117⁄64 15⁄16 500TC-822-SC 3⁄4 113⁄32 133⁄64 15⁄32 250TC-823-SC 1 19⁄16 121⁄32 127⁄64 200TC-824-SC 11⁄4 115⁄16 21⁄32 113⁄16 100TC-825-SC 11⁄2 29⁄32 23⁄8 23⁄64 40TC-826-SC 2 233⁄64 2 39⁄64 217⁄32 20TC-827-SC 21⁄2 33⁄16 3 9⁄32 319⁄64 12TC-828-SC 3 325⁄64 3 31⁄64 41⁄16 12TC-829-SC 31⁄2 331⁄64 3 19⁄32 417⁄32 10TC-8210-SC 4 347⁄64 3 53⁄64 51⁄16 6
• Concrete tightwhen taped
CONDUIT DIMENSIONS (IN.) STD.CAT NO. OFFSET (IN.) SIZE (IN.) A B C CTN.
TO 221 3⁄8 1⁄2 2.00 .90 .37 100TO 222 3⁄4 3⁄4 2.98 1.16 .25 100TO-223 3⁄4 1 3.15 1.42 .75 100UL File No. E-16592.
CSA File No. LR-18130M57.
A
BC
A
B
• Concrete tight when taped
CONDUIT DIMENSIONS (IN.) STD.CAT NO. SIZE (IN.) A B CTN.
TK-221 1⁄2 133⁄64 59⁄64 500TK-222 3⁄4 129⁄32 15⁄32 250TK-223 1 2 17⁄16 200TK-224 11⁄4 233⁄64 127⁄32 100TK-225 11⁄2 227⁄32 21⁄16 40
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
TK-226A 2 313⁄32 21⁄2 20TK-227 21⁄2 47⁄32 319⁄64 12TK-228 3 411⁄16 43⁄64 12TK-229 31⁄2 427⁄32 417⁄32 10TK-2210 4 515⁄32 49⁄16 6
A
B
• Concrete tight when taped
UL File No. E-16592 — 1⁄2"–2".
UL File No. E-23018 — 21⁄2"–4".
CSA File No. LR-12798 — 1⁄2"–1", 21⁄2"–4".
UL File No. E-16592 — 1⁄2"–2".
UL File No. E-23018 — 2 1⁄2"–4".
CSA File No. LR 12798 — 1⁄2"–2".
UL File No. E-16592 — 1⁄2"–2".
UL File No. E-23018 — 21⁄2"–4".
CSA File No. LR-12798 — 1⁄2"–11⁄4", 21⁄2"–4".
UL File No. E-16592 — 1⁄2"–2".
UL File No. E-23018 — 21⁄2"–4".
CSA File No. LR-12798 — 1⁄2"–11⁄4", 21⁄2"–4".
Set Screw Connectors — Die Cast Zinc, Offset
Set ScrewCouplings — Die Cast Zinc
Set Screw Connectors — Die Cast Zinc
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HT 221 1⁄2 EMT to 1⁄2 Rigid 1.67 1.07 500HT-222 3⁄4 EMT to 3⁄4 Rigid 1.98 1.29 250HT-223 1 EMT to 1 Rigid 2.15 1.58 100UL File No. E-23018.
A
B
• Concrete tight when taped
Combination Set Screw Couplings Thinwall to Heavywall — Die Cast Zinc
Thinwall Conduit Fittings (EMT)
F-8
Fitti
ngs
TRADE DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
EMT to Flex Compression to Screw-In Type — Die Cast Zinc
TX201 1⁄2 0.84 1.10 500TX-202 3⁄4 0.95 1.30 250
TRADE DIMENSIONS (IN.) STD.CAT. NO. FIG. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
EMT to Flex Set Screw Type — Die Cast Zinc
TX210 1 1⁄2–3⁄8 0.15 0.61 1.16 250TX211 2 1⁄2–1⁄2 0.60 1.00 1.71 250TX-212 2 3⁄4–3⁄4 0.78 1.20 1.93 200
Fig. 11⁄2"–3⁄8"
Fig. 21⁄2"–1⁄2" 3⁄4"–3⁄4"
B
A Max
A Min
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
TL-211 1⁄2 1.31 .93 100TL-212 3⁄4 1.47 1.22 50UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
TL 201 1⁄2 1.31 1.10 100TL-202-SC 3⁄4 1.60 1.24 50TL-203 1 1.94 1.59 25TL-204 11⁄4 2.26 1.97 25UL File No. E-23018.
A
B
A
B
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
Die Cast Zinc Flexible Metal Conduit to EMT
TX-220 3⁄8 Flex to 1⁄2 EMT 15⁄8 1⁄2 500TX-221 1⁄2 Flex to 1⁄2 EMT 113⁄16 15⁄32 250TX-222 3⁄4 Flex to 3⁄4 EMT 131⁄32 111⁄32 150TX-223 1 Flex to NMT 27⁄64 15⁄8 150UL File No. E-23018.
• Concrete tight when taped
Combination Set Screw Couplings
Combination Couplings
EMT to Box Set Screw Type —Die Cast Zinc
EMT to EMT Set Screw Type —Die Cast Zinc
Thinwall Conduit Fittings (EMT)
F-9
Fittings
A
B
TRADE DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
TC-201-SC 1⁄ 2 0.68 1.05 1,000UL File No. E16592.
EMT Connector
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BT-501 1⁄2 215⁄32 133⁄64 100BT-502 3⁄4 215⁄32 147⁄64 100BT-503 1 215⁄32 131⁄32 100BT-504 11⁄4 215⁄32 231⁄64 100BT-505 11⁄2 215⁄32 31⁄32 100
A
B
Space Cap
CONDUIT DIMENSIONS (IN.) STAINLESS STEEL REGULARCAT. NO. SIZE (IN.) A B STD. CTN. STD. CTN.
TS 101 1⁄2 0.57 1.79 25 100TS-102 3⁄4 0.62 1.96 25 50TS-103 1 0.75 2.25 25 50TS-104 11⁄4 0.88 2.85 10 25TS-105 11⁄2 0.99 3.16 5 20TS-106 2 1.10 3.93 5 10HS-107 21⁄2 1.28 5.00 5 25HS-108 3 1.28 5.55 5 25HS-109 31⁄2 1.28 6.37 5 10HS-110 4 1.28 6.87 5 10*Add SS suffix to part number for Stainless Steel.
• Steel
• Zinc plated
TRADE DIMENSIONS (IN.) STD.CAT. NO. TYPE SIZE (IN.) A B C CTN.
TC921 Set Screw Type 1⁄2 1.27 1.15 .45 200TC-911-SC Compression Type 1⁄2 1.37 1.15 .45 200TC-912-SC Compression Type 3⁄4 1.86 .95 .52 200
Set Screw Type Compression Type
A A
B BC C
CONDUIT DIMENSIONS (IN.) STAINLESS STEEL REGULARCAT. NO. SIZE (IN.) A B STD. CTN. STD. CTN.
TS-901 1⁄2 0.56 2.20 25 250TS-902 3⁄ 4 0.62 2.67 25 200TS-903 1 0.68 2.97 25 100TS-904 11⁄4 0.75 3.67 10 50TS-905 11⁄2 0.88 4.22 5 5TS-906 2 1.00 4.91 5 25*Add SS suffix to part number for Stainless Steel.
• Steel
• Zinc plated
RIGID/MC EMT FLEX DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) SIZE (IN.) SIZE (IN.) A B CTN.
N-101-SC — 1⁄2 3⁄8 115⁄16 15⁄64 1,000N-102-SC 1⁄2 3⁄4 1⁄2 23⁄16 117⁄32 1,000N-103-SC 3⁄4 1 — 23⁄8 115⁄32 1,000
• Stamped steel
• Zinc plated
B
A
A
B
One-Hole Snap Straps — Steel
Nail Straps — SteelSpace Caps — Plastic
Two-Hole EMT Straps —Steel — Malleable Insulated
EMT Connectors — Die Cast ZincTwo-Piece Type 90° Angle
Rigid/Intermediate Grade Conduit Fittings
F-10
Fitti
ngs
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HK-101 1⁄2 11⁄8 213⁄32 100HK-102 3⁄4 13⁄8 217⁄32 50HK-103 1 15⁄8 211⁄16 25HK-104 11⁄4 2 225⁄32 25HK-105 11⁄2 21⁄4 311⁄64 25Two set screws starting at 2".
UL File No. E-23018.
• Malleable iron/zinc plated
• Malleable iron/zinc plated
A
B
• Steel concrete tight when taped
• Zinc plated
A
B
• Steel (concrete tight) when taped
• Zinc plated
Rigid Connectors — Set Screw Type —Die Cast Zinc
TRADE DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HC-203 1 1.54 0.49 100HC-802 3⁄4 1.44 0.45 250HC-803 1 1.54 0.49 100
A
B
Rigid Couplings — Set Screw Type — Die Cast Zinc
TRADE DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HK 201 1⁄2 1.77 1.09 250HK-203 1 2.29 1.61 100
A
B
STD.CAT. NO. CONDUIT (IN.) CTN.
HC 401 1⁄2 300HC-402 3⁄4 150HC-403 1 90HC-404 11⁄4 60HC-405 11⁄2 30HC-406 2 12HC-407 21⁄2 12HC-408 3 6HC-409 31⁄2 6HC-410 4 6Suggested use — rigid conduit only.
UL File No. E-23018 1⁄2"–11⁄4".
Threadless CompressionConnectors
Set Screw Couplings
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HK-106 2 23⁄4 313⁄32 20HK-107 21⁄2 37⁄16 329⁄32 10HK-108 3 41⁄16 45⁄32 5HK-109 31⁄2 49⁄16 47⁄8 5HK-110 4 51⁄16 53⁄8 5Two set screws starting at 2".
UL File No. E-23018.
Threadless CompressionCouplings
STD.CAT. NO CONDUIT (IN.) CTN.
HK 401 1⁄2 300HK 402 3⁄4 150HK 403 1 90HK 404 11⁄4 60HK 405 11⁄2 30HK 406 2 6HK 407 21⁄2 6HK 408 3 4HK 409 31⁄2 4HK 410 4 4Suggested use — rigid conduit only.
UL File No. E-23018 1⁄2"–11⁄4".
Set Screw Connectors
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HC 101 1⁄2 11⁄8 11⁄8 100HC-102 3⁄4 13⁄8 11⁄2 50HC-103 1 5⁄8 113⁄16 50HC-104 11⁄4 2 2 25HC-105 11⁄2 21⁄2 23⁄8 25HC-106 2 23⁄4 23⁄8 20HC-107 21⁄2 313⁄32 35⁄16 10HC-108 3 41⁄32 37⁄16 5HC-109 31⁄2 49⁄16 313⁄16 5HC-110 4 53⁄32 43⁄32 5One set screw or two. Two set screws starting at 2" trade size.
Suggested use — rigid conduit only.
UL File No. E-23018 1⁄2" –11⁄4".
InsulatedCONDUIT DIMENSIONS (IN.) STD.
CAT. NO. SIZE (IN.) A B CTN.
HC 701 1⁄2 11⁄8 11⁄8 100HC-702 3⁄4 13⁄8 11⁄2 50HC-703 1 5⁄8 113⁄16 25HC-704 11⁄4 2 2 25HC-705 11⁄2 21⁄2 23⁄8 25HC-706 2 23⁄4 23⁄8 20HC-707 21⁄2 313⁄32 35⁄16 10HC-708 3 41⁄32 37⁄16 5HC-709 31⁄2 41⁄4 47⁄8 5HC-710 4 43⁄4 45⁄16 5One set screw or two. Two set screws starting at 2" trade size.
Suggested use — rigid conduit only.
UL File No. E-23018 1⁄2" –11⁄4".
Rigid/Intermediate Grade Conduit Fittings
F-11
Fittings
TRADE DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (ASSEMBLED) B CTN.
EK 201 1⁄2 1.39 1.31 100EK-202 3⁄4 1.53 1.58 50
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (ASSEMBLED) B CTN.
EK 401 1⁄2 11⁄16 11⁄8 100EK 402 3⁄4 11⁄8 111⁄32 50EK 403 1 13⁄8 15⁄8 25EK 404 11⁄4 121⁄32 25⁄32 25EK 405 11⁄2 17⁄8 223⁄32 25EK 406 2 2 333⁄64 20EK 407 21⁄2 21⁄2 329⁄64 10EK 408 3 33⁄8 423⁄32 6EK 409 31⁄2 35⁄8 55⁄32 5EK 410 4 329⁄32 529⁄32 5EK 411 5 45⁄16 7 1UL File No. E-23018 1⁄2"–4".
• 1⁄2"–21⁄2" — Steel
• 21⁄2"–6" — Malleable iron
• Zinc plated
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HL-611 1⁄2 1.31 1.09 100HL-612 3⁄4 1.47 1.29 50UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HL-601 1⁄2 1.31 1.10 100HL-602 3⁄4 1.60 1.24 50HL-603 1 1.95 1.59 25HL-604 11⁄4 2.26 1.97 30UL File No. E-23018.
SIZE DIMENSIONS (IN.) SHF. CTF./CAT. NO. (IN.) A B SHIP QTY.
HL-202-SC 3⁄4 1.17 1.04 25/250USE: To join rigid or IMC conduit at right angles where lack of room prevents using a standard sweep elbow, or to terminate a run of rigid or IMC conduit at a box.
UL Listing E37148.
A
B
AB
AB
HUB STD.CAT. NO. SIZE (IN.) CTN.
H050-SC 1⁄2 100H075-SC 3⁄4 100H100-SC 1 25H125-SC 11⁄4 25H150-SC 11⁄2 10H200-SC 2 5H250-SC 21⁄2 5H300-SC 3 2H350-SC 31⁄2 2H400-SC 4 1H500-SC 5 1H600-SC 6 1*Available in nickel-chrome plating or with PVC coating.
Consult customer service for price and delivery.
UL File No. E-23018.
• The T&B Hub with sealingring that will not fall out
• Provides superior sealingfor exceptional watertightperformance
• Color blue is a registeredtrademark of Thomas &Betts Corporation
H050-SC Series Hub
90° Short RadiusElbows — Die Cast Zinc
Three-PieceCouplings
Rigid Couplings — Three Piece Type — Die Cast Zinc
Pull Corner Elbows — Die Cast Zinc
Rigid to Box with Gasket — Die Cast Zinc
The T&B Hub — Zinc Die Cast with Insulated Throat*
Rigid/Intermediate Grade Conduit Fittings
F-12
Fitti
ngs B
A
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
841-TB 3⁄8 9⁄16 11⁄16 500HA-401 1⁄2 33⁄64 15⁄16 500HA-402 3⁄4 43⁄64 13⁄16 200HA-403 1 7⁄8 17⁄16 100HA-404 11⁄4 11⁄8 13⁄4 100HA-405 11⁄2 11⁄8 21⁄16 50HA-406 2 17⁄16 29⁄16 50HA-407 21⁄2 11⁄4 3 20HA-408 3 11⁄2 37⁄8 10HA-409 31⁄2 13⁄4 43⁄8 5HA-410 4 — — 5UL File No. E-23018 3⁄ 8"–31⁄2".
B
A
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HA-901 1⁄2 43⁄64 113⁄16 500HA-902 3⁄4 13⁄16 17⁄32 200HA-903 1 7⁄8 17⁄16 100HA-904 11⁄4 11⁄8 13⁄4 100HA-905 11⁄2 11⁄8 21⁄16 50HA-906 2 17⁄16 29⁄16 50UL File No. E-23018 3⁄8"–31⁄2".
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HA-201 1⁄2 0.98 0.59 1,000HA-202 3⁄4 1.18 0.70 500HA-203 1 1.50 0.80 250HA-204 11⁄4 1.75 1.06 250HA-205 11⁄2 2.11 1.01 100HA-206 2 2.61 1.20 40HA-207 21⁄2 3.13 1.49 40HA-208 3 3.90 1.65 40HA-209 31⁄2 4.20 1.68 40HA-210 4 4.79 1.73 20UL File No. E-23018 1⁄2"–2".
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HA-801 1⁄2 0.98 0.59 1,000HA-802 3⁄4 1.18 0.70 500HA-803 1 1.50 0.80 250HA-804 11⁄4 1.75 1.06 250HA-805 11⁄2 2.11 1.01 100HA-806 2 2.61 1.20 40HA-807 21⁄2 3.13 1.49 25HA-808 3 3.90 1.65 10HA-809 31⁄2 4.20 1.68 10HA-810 4 4.79 1.73 10UL File No. E-23018 1⁄2" & 3⁄4" only.
A
B
B
A
A
B
3⁄4"
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HO 221 1⁄2 2.60 1.00 100HO-222 3⁄4 2.62 1.32 100HO-223 1 2.68 1.51 100HO-224 11⁄4 2.85 1.85 50HO-225 11⁄2 2.88 2.08 50HO-226 2 3.19 2.71 203⁄4" offset.
UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
HA-211 1⁄2 1 15⁄16 1,000HA-212 3⁄4 1 13⁄16 500HA-213 1 1 17⁄16 250UL File No. E-23018 1⁄2" & 3⁄4" only.
Offset NipplesDie Cast Zinc
Conduit NipplesDie Cast Zinc —Insulated
Conduit NipplesIron/Zinc Plated —Insulated
Conduit NipplesIron/Zinc Plated
Conduit NipplesDie Cast Zinc — 1" Long
Conduit Nipples Die Cast Zinc — Non-Insulated
A
B
Rigid/Intermediate Grade Conduit Fittings
F-13
Fittings
AB
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) B (MAX.) CTN.
LN-100-SC 3⁄8 — — 1,000LN-101-SC 1⁄2 0.125 1.140 1,000LN-102 3⁄4 0.140 1.420 1,000LN-103 1 0.170 1.770 500LN-104 11⁄4 0.170 2.281 200LN-105 11⁄2 0.170 2.598 100LN-106 2 0.187 3.175 50LN-107 21⁄2 0.375 3.562 30LN-108 3 0.375 4.250 25LN-109 31⁄2 0.438 4.803 25LN-110 4 0.438 5.402 25LN-111 5 0.500 6.674 10LN-112 6 0.561 7.934 10UL File No. E-23018.
A
B
CONDUIT UNIT STD.CAT. NO. SIZE (IN.) QTY. CTN.
SPLN-107 21⁄2 30 30SPLN-108 3 25 25SPLN-109 31⁄2 25 25SPLN-110 4 25 25Not UL Listed.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) B (MAX.) CTN.
LS 101 1⁄2 0.26 1.12 1,000LS-102 3⁄4 0.27 1.37 1,000LS-103 1 0.28 1.75 500LS-104 11⁄4 0.32 2.06 200LS-105 11⁄2 0.32 2.37 100LS-106 2 0.32 2.87 50LS-107 21⁄2 0.32 3.43 50LS-108 3 0.32 4.12 50LS-109 31⁄2 0.32 4.62 50LS-110 4 0.32 5.18 25UL File No. E-23018.
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) B (MAX.) CTN.
LN-201 1⁄2 0.125 1.140 2,000LN-202 3⁄4 0.140 1.420 1,000LN-203 1 0.170 1.770 1,000LN-204 11⁄4 0.170 2.281 500LN-205 11⁄2 0.170 2.598 500LN-206 2 0.187 3.175 200LN-207 21⁄2 0.375 3.562 100LN-208 3 0.375 4.250 100LN-209 31⁄2 0.438 4.803 40LN-210 4 0.438 5.402 40CSA File No. LR-12798.
UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) B (MAX.) CTN.
LG-401 1⁄2 0.125 1.140 100LG-402 3⁄4 0.140 1.420 100LG-403 1 0.170 1.770 50LG-404 11⁄4 0.170 2.281 50LG-405 11⁄2 0.170 2.598 50LG-406 2 0.187 3.175 25LG-407 21⁄2 0.375 3.562 10LG-408 3 0.375 4.250 10LG-409 31⁄2 0.438 4.803 50LG 410 4 0.438 5.402 5UL File No. E-23018.
TRADE A DIA. B THD. STD. CAT. NO. SIZE (IN.) (IN.) (IN.) CTN.
LN-501 1⁄2 1.3 1⁄2–14 100LN-502 3⁄4 1.4 3⁄4–14 100LN-503 1 1.7 1–111⁄2 50Material: Nylon 6/6.
Color: Gray.
.200"
A
B Thd.
LocknutsSteel /Zinc Plated
LocknutsDie Cast Zinc
Sealing LocknutsSteel/Zinc Plated
Grounding LocknutsMalleable — Iron/Zinc Plated
LocknutsNon-Metallic
Thin ConstructionLocknuts — Steel/Zinc Plated
Rigid/Intermediate Grade Conduit Fittings
F-14
Fitti
ngs
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BU-401 1⁄2 11⁄32 7⁄16 1,000BU-402 3⁄4 11⁄4 7⁄16 1,000BU-403 1 19⁄16 1⁄2 500BU-404 11⁄4 115⁄16 17⁄32 200BU-405 11⁄2 213⁄64 9⁄16 100BU-406 2 245⁄64 9⁄16 50UL File No. E-23018.
TRADE GROUNDING LUG WIRE SIZE STD.CAT. NO. SIZE (IN.) MIN. MAX. CTN.
BG201 1⁄2 14 4 500BG-202 3⁄4 14 4 500BG-203 1 14 4 250BG-204A 11⁄4 14 4 200BG-204 11⁄4 8 1/0 200BG-205A 11⁄2 11 4 100BG-205 11⁄2 8 1/0 50BG-206A 1 14 4 100BG-206 2 8 1/0 50UL File No. E-3060.
• 105° C thermoplastic liners
• Heavy reinforced ribs
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BU-801 1⁄2 1.06 0.43 1,000BU-802 3⁄4 1.31 0.43 1,000BU-803 1 1.59 0.48 500BU-804 11⁄4 1.96 0.56 250BU-805 11⁄2 2.18 0.60 250UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) B (MAX.) CTN.
BU201 1⁄2 1.05 0.37 1,000BU-202 3⁄4 1.32 0.37 1,000BU-203 1 1.58 0.47 500BU-204 11⁄4 1.94 0.50 250BU-205 11⁄2 2.20 0.52 250UL File No. E-23018.
A
B
Conduit Bushings Die CastZinc — Heavy Reinforced Ribs
Grounding BushingsDie Cast Zinc — InsulatedMetallic With AluminumLay-in Type Lug
A
B
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BU-501 1⁄2 13⁄32 11⁄16 400BU-502 3⁄4 13⁄32 119⁄64 400BU-503 1 9⁄16 19⁄16 200BU-504 11⁄4 9⁄16 129⁄32 100BU-505 11⁄2 9⁄16 23⁄16 100BU-506 2 5⁄8 211⁄16 60UL File No. E-23018 1⁄2"–4" only.Rated 105° C.
Insulated Bushings —Thermoplastic
Bushings — Iron/Zinc Plated
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BU-806 2 2.68 0.56 250BU-807 21⁄2 3.25 0.90 50BU-808 3 3.87 0.85 25BU-809 31⁄2 4.37 0.93 25BU-810 4 5.00 0.93 10UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) B (MAX.) CTN.
BU-206 2 2.69 0.52 250BU-207 21⁄2 3.23 0.85 50BU-208 3 3.84 0.85 25BU-209 31⁄2 4.35 0.85 25BU-210 4 5.02 0.85 10UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BU-507 21⁄2 23⁄32 33⁄16 20BU-508 3 9⁄16 327⁄32 20BU-509 31⁄2 3⁄4 423⁄64 5BU-510 4 25⁄32 427⁄32 5BU-511 5 1 65⁄16 5BU-512 6 1 77⁄16 5UL File No. E-23018 1⁄2"–4" only.Rated 105° C.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BU-407 21⁄2 33⁄16 11⁄32 30BU-408 3 35⁄8 25⁄32 25BU-409 31⁄2 41⁄16 27⁄32 25BU-410 4 421⁄32 15⁄16 25BU-411 5 421⁄32 15⁄16 10UL File No. E-23018.
TRADE GROUNDING LUG WIRE SIZE STD.CAT. NO. SIZE (IN.) MIN. MAX. CTN.
BG-207 21⁄2 8 1/0 50BG-207A 21⁄2 6 250 kcmil 50BG-208 3 8 1/0 50BG-208A 3 6 250 kcmil 50BG-209 31⁄2 8 1/0 10BG-209A 31⁄2 6 250 kcmil 10BG-210 4 8 1/0 10BG-210A 4 6 250 kcmil 10UL File No. E-3060.
A
B
• 105°C thermoplastic liners
• Heavy reinforced ribs
Conduit Bushings Die Cast Zinc — Insulated Metallic
Rigid/Intermediate Grade Conduit Fittings
F-15
Fittings
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BI-906 2 245⁄64 5⁄8 50BI-907 21⁄2 37⁄32 9⁄16 30BI-908 3 327⁄32 9⁄16 25BI-909 31⁄2 47⁄16 7⁄8 25BI910 4 431⁄32 29⁄32 25UL File No. E-23018.
CONDUIT GROUNDING DIMENSIONSSIZE LUG WIRE (IN.) STD.
CAT. NO. (IN.) CAPACITY A B CTN.
BG-801 1⁄2 — 11⁄32 1⁄2 500BG-802 3⁄4 #14– #4 CU 11⁄4 1⁄2 500BG-803 1 or 19⁄16 9⁄16 250BG-804 11⁄4 # 1 2 – # 4 A L 115⁄16 19⁄32 150BG-805 11⁄2 — 213⁄64 5⁄8 150UL File No. E-3060.1⁄2"–2" Iron, 2 1⁄4"–4" Die Cast Zinc.
TRADE GROUNDING LUG WIRE SIZE STD.CAT. NO. SIZE (IN.) MIN. MAX. CTN.
BG801A 1⁄2 14 6 500BG-802A 3⁄4 14 6 500BG-803A 1 14 6 250BG-804A 11⁄4 14 2 200BG- 805A 11⁄2 14 2 100BG-806A 2 14 2 100UL File No. E-3060.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
RB 121 3⁄4–1⁄2 9⁄16 7⁄8 100RB-131 1–1⁄2 5⁄8 11⁄8 50RB-132 1–3⁄4 5⁄8 11⁄8 50RB-141 11⁄4–1⁄2 11⁄16 17⁄16 50RB 142 11⁄4–3⁄4 11⁄16 17⁄16 50RB-143 11⁄4–1 11⁄16 17⁄16 50RB-151 11⁄2–1⁄2 23⁄32 111⁄16 50RB-152 11⁄2–3⁄4 23⁄32 111⁄16 50RB-153 11⁄2–1 23⁄32 111⁄16 50RB-154 11⁄2–11⁄4 23⁄32 111⁄16 50UL File No. E-23018.
Insulated Bushings —Iron/Zinc Plated
Insulated GroundingBushings — MalleableIron/Zinc Plated
Reducing Bushings• RB-121 thru RB-165 — Steel
• RB-175 thru RB-187 — Malleable iron(concrete tight), zinc plated
Grounding BushingsMalleable Iron/Zinc Plated —Insulated With Aluminum Lug• For copper or aluminum
bare ground wire
• 105°C thermoplastic liners
• Heavy reinforced ribs
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BI 901 1⁄2 11⁄32 1⁄2 1,000BI-902 3⁄4 11⁄4 1⁄2 1,000BI-903 1 19⁄16 9⁄16 500BI-904 11⁄4 115⁄16 19⁄32 200BI-905 11⁄2 213⁄64 5⁄8 100UL File No. E-23018.
CONDUIT GROUNDING DIMENSIONSSIZE LUG WIRE (IN.) STD.
CAT. NO. (IN.) CAPACITY A B CTN.
BG-806 2 — 245⁄64 5⁄8 100BG-807 21⁄2 #14–1/0 CU 33⁄16 9⁄16 60BG-808 3 or #12–1/0 AL 35⁄8 9⁄16 30BG-809 31⁄2 #6–250 kcmi l 41⁄16 7⁄8 30BG-810 4 CU or AL 421⁄32 29⁄32 30UL File No. E-3060.1⁄2"–2" Iron, 2 1⁄4"–4" Die Cast Zinc.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
RB-161 2–1⁄2 27⁄32 23⁄32 25RB-162 2–3⁄4 27⁄32 23⁄32 25RB-163 2–1 27⁄32 23⁄32 25RB-164 2–11⁄4 27⁄32 23⁄32 25RB-165 2–11⁄2 27⁄32 23⁄32 25RB-175 21⁄2–11⁄2 7⁄8 213⁄16 25RB-176 21⁄2–2 7⁄8 213⁄16 25RB-186 3–2 29⁄32 27⁄16 25RB-187 3–21⁄2 29⁄32 27⁄16 25UL File No. E-23018.
TRADE GROUNDING LUG WIRE SIZE STD.CAT. NO. SIZE (IN.) MIN. MAX. CTN.
BG-807A 21⁄2 14 2/0 50BG-808A 3 14 2/0 50BG-809A 31⁄2 14 2/0 10BG-810A 4 14 2/0 10BG-810B 4 6 250 kcmil 10UL File No. E-3060.
B
A
Rigid/Intermediate Grade Conduit Fittings
F-16
Fitti
ngs B
A
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
RB 421 3⁄4–1⁄2 5⁄8 13⁄16 100RB-432 1⁄2–3⁄4 1 13⁄16 100RB-443 1–3⁄4 11⁄16 13⁄16 50UL File No. E-23018.
SCREW CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE SIZE (IN.) A B CTN.
HS-100-SC 10 3⁄8 3⁄4 147⁄64 1,000HS-101 1⁄4 1⁄2 1 115⁄16 500HS-102 1⁄4 3⁄4 1 25⁄64 500HS-103 1⁄4 1 1 213⁄32 250HS-104 5⁄16 11⁄4 1 33⁄32 100HS-105 3⁄8 11⁄2 13⁄16 313⁄32 100HS-106 3⁄8 2 13⁄16 327⁄32 100HS-107 7⁄16 21⁄2 11⁄4 51⁄16 25HS-108 1⁄2 3 13⁄8 57⁄8 25HS-109 1⁄2 31⁄2 13⁄8 61⁄4 10HS-110 1⁄2 4 13⁄8 67⁄8 10Available in one-hole and two-hole in stainless steel.Add SS suffix to part number for Stainless Steel.
A
B
SCREW CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE SIZE (IN.) A B C CTN.
HS-901 8 1⁄2 3⁄4 27⁄16 3⁄16 1,200HS-902 10 3⁄4 3⁄4 211⁄16 3⁄16 900HS-903 1⁄4 1 3⁄4 37⁄16 3⁄16 600HS-904 1⁄4 11⁄4 3⁄4 327⁄32 3⁄16 450HS-905 1⁄4 11⁄2 3⁄4 41⁄16 3⁄16 50HS-906 1⁄4 2 3⁄4 47⁄16 3⁄16 150HS-907 1⁄4 21⁄2 1 51⁄8 1⁄4 150HS-908 1⁄2 3 1 63⁄16 1⁄4 60HS-909 1⁄4 31⁄2 1 73⁄16 1⁄4 60HS-910 1⁄4 4 1 811⁄16 1⁄4 60CSA Certified.
Add SS suffix to part number for Stainless Steel.
A
B
C
Reducers —Malleable Iron/Zinc Plated
CONDUIT DIAMETER (IN.) STD. CAT. NO. SIZE (IN.) A B C CTN.
WA 110 1⁄2–3⁄8 13⁄16 11⁄16 27⁄32 500WA-121 3⁄4–1⁄2 11⁄2 7⁄8 11⁄16 500WA-131 1–1⁄2 13⁄4 7⁄8 15⁄16 500WA-132 1–3⁄4 13⁄4 13⁄32 15⁄16 500WA-141 11⁄4–1⁄2 23⁄16 7⁄8 111⁄16 200WA-142 11⁄4–3⁄4 23⁄16 13⁄32 111⁄16 200WA-143 11⁄4–1 23⁄16 123⁄64 111⁄16 200WA-151 11⁄2–1⁄2 25⁄8 7⁄8 17⁄8 200WA-152 11⁄2–3⁄4 25⁄8 13⁄32 17⁄8 200WA-153 11⁄2–1 25⁄8 123⁄64 17⁄8 200WA-154 11⁄2–11⁄4 25⁄8 123⁄32 17⁄8 200WA-161 2–1⁄2 31⁄4 7⁄8 23⁄8 100WA-162 2–3⁄4" 31⁄4 13⁄32 23⁄8 100WA-163 2–1 31⁄4 123⁄64 23⁄8 100WA-164 2–11⁄4 31⁄4 123⁄32 23⁄8 100WA-165 2–11⁄2 31⁄4 131⁄32 23⁄8 100WA-171 21⁄2–1⁄2 31⁄4 7⁄8 27⁄8 100WA-172 21⁄2–3⁄4 31⁄4 13⁄32 27⁄8 100WA-173 21⁄2–1 31⁄4 123⁄64 27⁄8 100WA-174 21⁄2–11⁄4 31⁄4 123⁄32 27⁄8 100WA-175 21⁄2–11⁄2 31⁄4 131⁄32 27⁄8 100WA-176 21⁄2–2 31⁄4 27⁄16 27⁄8 100WA-181 3–1⁄2 41⁄2 7⁄8 31⁄2 100WA-182 3–3⁄4 41⁄2 123⁄32 31⁄2 100WA-183 3–1 41⁄2 123⁄64 31⁄2 100WA-184 3–11⁄4 41⁄2 123⁄32 31⁄2 100WA-185 3–11⁄2 41⁄2 131⁄32 31⁄2 100WA-186 3–2 41⁄2 27⁄16 31⁄2 100WA-187 3–21⁄2 41⁄2 25⁄16 31⁄2 100WA-121 thru WA-165 CSA Listed.
A
B
C
Reducing Washers —Steel/Zinc Plated
One-Hole Straps —Steel/Zinc Plated
Two-Hole Straps —Steel/Zinc Plated
Rigid/Intermediate Grade Conduit Fittings
F-17
Fittings
A
B
SCREW CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE SIZE (IN.) A B CTN.
HS-400 10 3⁄8 111⁄16 17⁄32 500HS-401 1⁄4 1⁄2 21⁄64 5⁄8 500HS-402 1⁄4 3⁄4 27⁄16 13⁄16 500HS-403 1⁄4 1 27⁄8 15⁄16 100HS-404-SC 5⁄16 11⁄4 35⁄16 11⁄32 100HS-405 3⁄8 11⁄2 33⁄4 11⁄8 50HS-406 1⁄2 2 419⁄32 15⁄16 25HS-407 5⁄8 21⁄2 511⁄16 15⁄8 25HS-408 5⁄8 3 67⁄8 17⁄8 25HS-409 5⁄8 31⁄2 723⁄32 21⁄8 10HS-410 5⁄8 4 89⁄16 23⁄8 10HS-411 5⁄8 5 109⁄32 25⁄8 5Available in one-hole and two-hole in Stainless Steel.
Add SS suffix to part number for Stainless Steel.
Pipe Straps —Malleable Iron/Zinc Plated
RIGID/MC EMT FLEX DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) SIZE (IN.) SIZE (IN.) A B CTN.
N-101-SC — 1⁄2 3⁄8 25⁄32 15⁄64 1,000N-102-SC 1⁄2 3⁄4 1⁄2 25⁄16 17⁄32 1,000N-103-SC 3⁄4 1 — 23⁄8 115⁄32 1,000
B
A
CONDUIT DIA. DEPTH STD.CAT. NO. SIZE (IN.) A (IN.) B (IN.) CTN.
FP 401 1⁄2 3 .625 50FP-402 3⁄4 33⁄8 .656 50FP-403 1 35⁄8 .765 50FP-404 11⁄4 4 .875 25FP-405 11⁄2 43⁄8 .937 25FP-406 2 47⁄8 .843 25
B
5⁄16"Bolt Hole
A
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
CB-201 1⁄2 2 1 1,000CB-202 3⁄4 23⁄8 11⁄16 500CB-203 1 23⁄4 15⁄16 500CB-204 11⁄4 33⁄8 11⁄2 250CB-205 11⁄2 313⁄16 15⁄8 100CB-206 2 41⁄2 2 50
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BR-501 1⁄2 215⁄32 121⁄32 100BR-502 3⁄4 215⁄32 155⁄64 100BR-503 1 215⁄32 21⁄8 100BR-504 11⁄4 215⁄32 261⁄64 100BR-505 11⁄2 215⁄32 313⁄64 100
A
B
• Steel
• Zinc plated
CONDUIT STD.CAT. NO. SIZE (IN.) DIAMETER (IN.) CTN.
BL-111 1⁄2 15⁄64 1,000BL-112 3⁄4 11⁄4 1,000BL-113 1 11⁄2 1,000BL-114 11⁄4 113⁄16 500BL-115 11⁄2 27⁄32 500BL-116 2 211⁄16 250
A
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
BS 201 1⁄2 11⁄8 13⁄32 500UL File No. E-23018.
Nail Strap —Stamped Steel/Zinc Plated
Rigid/IntermediateSpace Caps — Plastic
Flange Plates —Malleable Iron/Zinc Plated
Snap-in Blanks
Pipe Spacersfor Rigid/Intermediate or Thinwall — Die Cast Zinc
Box Spacer —Die Cast Zinc( 1⁄4" Space)
Flexible Cord & Power Cable Connectors
F-18
Fitti
ngs
BLACK BEAUTY®Non-MetallicLiquidtight StrainRelief Connectors
A Max.Hex Flat
Throat Size
Hub N.P.T.THD
C
BodyGland
BChuck
NeopreneBushingSeal
LR 52391
E 13938
LR 52391E 13938
Neoprene Bushing SealChuck
BD
C
Throat Size
Wrench Flat
A (Max.)Hub N.P.T. Thd
90º ElbowGland
StraightTRADE THROAT HEX DIMENSIONS (IN.)OR HUB CORD SIZE FLAT A B C STD.
CAT. NO. SIZE (IN.) RANGE ± .03 ± .06 MAX. ± .06 ± .06 CTN.
2671† 3⁄8 .125–.275 0.33 .78 2.0 .90 .46 2502690† 1⁄2 .125–.275 0.33 1.00 2.3 .90 .60 1002672 1⁄2 .250–.400 0.55 1.08 2.6 1.27 .60 1002673* 1⁄2 .400–.560 0.55 1.08 2.6 1.27 .60 1002691* 1⁄2 .560–.690 0.54 1.32 3.0 1.57 .60 1002692* 1⁄2 .660–.780 0.54 1.32 3.0 1.57 .60 1002693 3⁄4 .250–.400 0.55 1.22 2.7 1.27 .62 1002694* 3⁄4 .400–.560 0.55 1.22 2.7 1.27 .62 1002674 3⁄4 .560–.690 0.79 1.34 3.0 1.57 .62 1002675 3⁄4 .660-.780 0.79 1.34 3.0 1.57 .62 1002696* 3⁄4 .770–.895 0.76 1.64 3.2 1.89 .62 1002676 1 .660–.780 0.98 1.60 3.3 1.89 .77 1002677 1 .770–.895 0.98 1.60 3.3 1.89 .77 1002678 1 .870–1.020 0.98 1.60 3.3 1.89 .77 502699 1 .890–1.090 0.98 2.25 4.2 2.58 .77 102702 11⁄4 .890–1.090 1.25 2.25 4.2 2.58 .80 102703* 11⁄4 1.080–1.280 1.25 2.25 4.0 2.58 .80 102704* 11⁄4 1.270-1.470 1.25 2.25 4.0 2.58 .80 102705-TB 11⁄4 .890-1.150 1.47 2.65 4.2 2.95 .82 102706 11⁄4 1.140-1.400 1.47 2.65 4.3 2.95 .82 102707* 11⁄4 1.390–1.650 1.47 2.65 4.3 2.95 .82 102708 2 1.190–1.530 1.89 3.13 5.1 3.50 .84 52709 2 1.520–1.860 1.89 3.13 4.9 3.50 .84 52710* 2 1.850–2.190 1.89 3.13 4.9 3.50 .84 5*Remove sufficient outer covering of cable to permit conductors to pass through connector body.
†CSA certified for factory installation.
Material: Weather-stabilized nylon, rated at – 34°C to 105°C.
For 90° style see AS-72555.
90º AngleTRADEOR HUB CORD THROAT HEX DIMENSIONS (IN.) STD.
CAT. NO. SIZE (IN.) RANGE SIZE FLAT A B C D CTN.
2680 † 3⁄8 .125–.275 .33 .62 1.8 .90 .46 1.00 1002681 1⁄2 .250–.400 .55 .83 2.5 1.27 .60 1.35 502682* 1⁄2 .400–.560 .55 .83 2.5 1.27 .60 1.35 502683 3⁄4 .560-.690 .78 1.06 2.8 1.57 .62 1.60 502684 3⁄4 .660–.780 .78 1.06 2.8 1.57 .62 1.60 502688 1 .560–.690 1.00 1.280 3.0 1.89 .77 1.90 252685 1 .660–.780 1.00 1.280 3.0 1.89 .77 1.90 252686 1 .770–.895 100 1.280 3.0 1.89 .77 1.90 252687 * 1 .870–1.020 1.00 1.280 3.0 1.89 .77 1.90 25* Remove sufficient outer covering of cable to permit conductors to pass through connector body.
† CSA certified for factory installation.
• Installs on cord by hand
• Achieves maximum pullout strengthwithout installation tools
• Each hub size takes a range of cord diameters
• Non-metallic construction providescorrosion resistance
• Weather-stabilized nylon ratedat –34°C to 105°C
Liquidtight Flexible Metal Conduit and Connectors
F-19
Fittings StraightC 5.015 (0.40) MIN.
A5 .015 B 5.35 ACROSS THROAT E FTRADE (0.40) IN. (0.90) IN. CORNERS DIA. D. THREAD INCH (MM) STD.
CAT. NO. SIZE (IN.) (MM) (MM) IN. (MM) IN. (MM) NPT. APPROX. CTN.
LT-500 3⁄8 .570 1.595 (40.51) 1.354 .417 1⁄2–14 1.880 (47.75) 100LT-501 1⁄2 .570 1.636 (41.55) 1.448 .550 1⁄2–14 1.986 (50.44) 100LT-502 3⁄4 .582 1.757 (44.63) 1.740 .740 3⁄4–14 2.212 (56.18) 50LT-503 1 .726 1.923 (48.84) 2.068 .940 111⁄12 2.508 (63.70) 50
A
D
B
C
E Thread
90° AngleC 5.015 (0.40) MIN.
A5 .015 B 5.35 ACROSS THROAT E FTRADE (0.40) IN. (0.90) IN. CORNERS DIA. D. THREAD INCH (MM) STD.
CAT. NO. SIZE (IN.) (MM) (MM) IN. (MM) IN. (MM) NPT. APPROX. CTN.
LT-590 3⁄8 (14.48) 1.380 (35.05) (34.39) (10.59) 1⁄2–14 1.880 (47.75) 50LT-591 1⁄2 (14.48) 1.489 (37.82) (36.78) (13.97) 1⁄2–14 1.986 (50.44) 50LT-592 3⁄4 (14.78) 1.790 (45.47) (44.20) (18.80) 3⁄4–14 2.212 (56.18) 50LT-593 1 (18.44) 2.104 (53.44) (52.53) (23.88) 111⁄12 2.508 (63.70) 25E Thread
A
D
B
F
C
Standard Material/Finish:• Body/Gland — Nylon-Gray
• O-Ring — Nitrate (Black)
• Locknut — Nylon
• Temp. Rating — 80°C
• Material Flammability Rating: UL94-V2
45° AngleC 5.015 (0.40) MIN.
A5 .015 B 5.35 ACROSS THROAT E FTRADE (0.40) IN. (0.90) IN. CORNERS DIA. D. THREAD IN. (MM) STD.
CAT. NO. SIZE (IN.) (MM) (MM) IN. (MM) IN. (MM) NPT. APPROX. CTN.
LT-540 3⁄8 (14.48) 2.012 (51.10) (34.39) (10.59) 1⁄2–14 1.534 (38.95) 50LT-541 1⁄2 (14.48) 2.092 (53.14) (36.78) (13.97) 1⁄2–14 1.590 (40.39) 50LT-542 3⁄4 (14.78) 2.452 (62.28) (44.20) (18.80) 3⁄4–14 1.821 (46.25) 50LT-543 1 (18.44) 2.684 (68.17) (52.53) (23.88) 111⁄12 2.034 (51.66) 25D
A
BF
C
Liquidtight Flex for Type B Non-Metallic Conduit
Listed/Certified by:• UL Listed (File # E23018)
• CSA Certified (File # LR52391)
• Conforms to watertightrequirements for Type 4
Liquidtight Flexible Metal Conduit and Connectors
F-20
Fitti
ngs
CAT. NO. TRADE I.D. (IN.) O.D. (IN.) STD.SERIES SIZE (IN.) MIN. MAX. MIN. MAX. CTN.
LTC038GY 3⁄8 .484 .504 .690 .710 100LTC050GY 1⁄2 .622 .642 .820 .840 100LTC075GY 3⁄4 .820 .840 1.030 1.050 100LTC100GY 1 1.041 1.066 1.290 1.315 100LTC125GY 11⁄4 1.380 1.410 1.630 1.660 100LTC150GY 11⁄2 1.575 1.600 1.865 1.900 50LTC200GY 2 2.020 2.045 2.340 2.375 50UL Listed: File E95745.
For use with Thomas & Betts LT38P, LT38M, LT500 series and Liquidtight Flexible Metal Conduit Fittings.
For Non-Metallic Flexible ConduitCAT. NO. DESCRIPTION
XF-CUT For Cutting Non-Metallic Flexible Conduit up to 1"XF-BLADE Replacement Blade for XF-CUT
O.D. I.D.
. . . . . . . . Specifications . . . . . . . . . .• Color: Gray
• Length: 100 ft. for LTC038GY thru LTC125GY50 ft. for LTC150GY and LTC200GY
• UL Temperature Rating:80° C dry, 60° C wet70° C oil. res. sunlight resistant,outdoor, direct burial
• CSA Certified: File LR 80349-2
• CSA Temperature Rating: -18°C to 75°C
• Material: PVC Helix reinforcement surroundedwith flexible PVC
• Voltage Rating: 600V
CONDUIT WIRE STD.CAT. NO. SIZE (IN.) LENGTH (FT.) GAUGE CTN.
LTWHIP 12-6-10 1⁄2 6 #10 6LTWHIP 12-4-10 1⁄2 4 #10 6LTWHIP 34-6-8 3⁄4 6 #8 6LTWHIP 34-4-8 3⁄4 4 #8 6
Whip with Metallic Fittings — One Straight, One 90°
LTWM 12-6-10 1⁄2 6 #10 6LTWM 12-4-10 1⁄2 4 #10 6LTWM 34-6-8 3⁄4 6 #8 6LTWM 34-4-8 3⁄4 4 #8 6
Liquidtight Whip Assembly
Conduit Cutter
Outdoor XTRA FLEX®Raceway System (Type B)
Liquidtight Flexible Metal Conduit and Connectors
F-21
Fittings
A
C
TRADE STD.CAT. NO. SIZE (IN.) A (IN.) B C (IN.) CTN.
5341GR 3⁄8 19⁄16 14-4 11⁄16 505342GR 1⁄2 17⁄8 14-4 13⁄8 505343GR 3⁄4 21⁄8 14-4 13⁄16 505344GR 1 21⁄4 14-4 13⁄4 255241GR 3⁄8 19⁄16 14-4 11⁄16 505242GR 1⁄2 17⁄8 14-4 13⁄8 505243GR 3⁄4 21⁄8 14-4 13⁄16 505244GR 1 21⁄4 14-4 13⁄4 25
A
C
B Lug Range
TRADE STD.CAT. NO. SIZE (IN.) A (IN.) B CTN.
5271GR 3⁄8 15⁄32 14-4 505272GR 1⁄2 13⁄8 14-4 505273GR 3⁄4 121⁄32 14-4 505274GR 1 17⁄8 14-4 25
AA
B Lug Range
Liquidtight Fittings — 45° Type
Liquidtight to Rigid External Ground Adapter
GROUNDINGDEVICE TRADE(LUG ONLY) SIZE STD.
CAT. NO. CAT. NO. (IN.) A (IN.) B CTN.
5331GR 38GR-TB 3⁄8 11⁄2 14-4 1005332GR 12GR-TB 1⁄2 19⁄16 14-4 1005333GR 34GR-TB 3⁄4 15⁄8 14-4 255334GR 1GR-TB 1 21⁄16 14-4 505231GR 38GR-TB 3⁄8 11⁄2 14-4 1005232GR 12GR-TB 1⁄2 19⁄16 14-4 100
B Lug Range
A
GROUNDING DEVICE(LUG ONLY) TRADE STD.
CAT. NO. CAT. NO. SIZE (IN.) A (IN.) B (IN.) C CTN.
5351GR 38GR-TB 3⁄8 13⁄8 11⁄4 14-4 505352GR 12GR-TB 1⁄2 19⁄16 17⁄16 14-4 505353GR 34GR-TB 3⁄4 13⁄4 13⁄16 14-4 505354GR 1GR-TB 1 23⁄16 21⁄16 14-4 255251GR 38GR-TB 3⁄8 13⁄8 11⁄4 14-4 505252GR 12GR-TB 1⁄2 19⁄16 17⁄16 14-4 505253GR 34GR-TB 3⁄4 13⁄4 113⁄16 14-4 505254GR 1GR-TB 1 23⁄16 21⁄16 14-4 255251ALGR 38GR-TB 3⁄8 13⁄8 11⁄4 14-4 505252ALGR 12GR-TB 1⁄2 19⁄16 17⁄16 14-4 505253ALGR 13GR-TB 3⁄4 13⁄4 113⁄16 14-4 505254ALGR 1GR-TB 1 23⁄16 21⁄16 14-4 25
C Lug Range A
B
Liquidtight Fittings
Liquidtight Fittings — 90° Type
GROUNDINGDEVICE TRADE(LUG ONLY) SIZE STD.
CAT. NO. CAT. NO. (IN.) A (IN.) B CTN.
5233GR 34GR-TB 3⁄4 15⁄8 14-4 255234GR 1GR-TB 1 21⁄16 14-4 505231ALGR 38GR-TB 3⁄8 11⁄2 14-4 1005232ALGR 12GR-TB 1⁄2 19⁄16 14-4 1005233ALGR 13GR-TB 3⁄4 15⁄8 14-4 505234ALGR 1GR-TB 1 21⁄16 14-4 50
Liquidtight Flexible Metal Conduit and Connectors
F-22
Fitti
ngs
• 3⁄8"–1", steel
• 11⁄4"–4", malleable iron/zinc plated • 3⁄8"–1", steel
• 11⁄4"–4", malleable iron/zinc plated (with insulated throat)
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LT 100 3⁄8 11⁄16 1⁄2 113⁄16 100LT-101 1⁄2 13⁄16 39⁄64 17⁄8 100LT-102 3⁄4 17⁄16 9⁄16 21⁄32 50LT-103 1 13⁄4 5⁄8 29⁄32 50LT-104 11⁄4 27⁄16 11⁄16 219⁄32 25LT-105 11⁄2 23⁄4 25⁄32 225⁄32 10LT-106 2 317⁄32 25⁄32 3 5CSA File No. LR-12798.
UL File No. E-23018 — 1⁄4"–4".
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) E F G I CTN.
LT-950 3⁄8 1.140 .500 1.150 1.480 50LT-951 1⁄2 1.250 .500 1.280 1.510 50LT-952 3⁄4 1.280 .520 1.550 1.540 50LT-953 1 1.430 .650 1.800 1.810 25LT-954 11⁄4 1.500 .660 2.250 2.160 25LT-955 11⁄2 1.610 .730 2.440 2.430 10LT-956 2 1.760 .750 2.970 2.820 5LT-959 31⁄2 2.610 1.180 5.250 5.930 1
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) E F G H CTN.
LT-450 3⁄8 1.140 .500 1.150 1.480 50LT-451 1⁄2 1.250 .500 1.280 1.510 50LT-452 3⁄4 1.280 .520 1.550 1.540 50LT-453 1 1.430 .650 1.800 1.810 25LT-454 11⁄4 1.500 .660 2.250 2.160 25LT-455 11⁄2 1.610 .730 2.440 2.430 10LT-456 2 1.760 .750 2.970 2.820 5LT-459 31⁄2 2.610 1.180 5.250 5.930 1CSA File No. LR-12798.
UL File No. E-23018.
AB
C A
B
CD
G
E
F
H I
45º
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) J K L M CTN.
LT-490 3⁄8 11⁄16 1⁄2 17⁄8 13⁄8 50LT-491 1⁄2 13⁄16 1⁄2 2 113⁄32 50LT-492 3⁄4 17⁄16 9⁄16 23⁄16 121⁄32 50LT-493 1 13⁄4 5⁄8 29⁄16 17⁄8 2525CSA File No. LR-12798.
UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) J K L N CTN.
LT-990 3⁄8 11⁄16 1⁄2 17⁄8 115⁄32 50LT-991 1⁄2 13⁄16 1⁄2 2 11⁄2 50LT-992 3⁄4 17⁄16 9⁄16 23⁄16 13⁄4 50LT-993 1 13⁄4 5⁄8 23⁄16 131⁄32 50
J
L
K
M N
Straight Connectors
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LT-700 3⁄8 11⁄16 1⁄2 129⁄32 100LT-701 1⁄2 13⁄16 39⁄64 131⁄32 100LT-702 3⁄4 17⁄16 9⁄16 21⁄8 50LT-703 1 13⁄4 5⁄8 23⁄8 50LT-704 11⁄4 27⁄16 11⁄16 211⁄16 25LT-705 11⁄2 23⁄4 25⁄32 27⁄8 10LT-706 2 317⁄32 25⁄32 35⁄16 5LT-707 21⁄2 23⁄16 1 4 1LT-708 3 21⁄2 15⁄32 43⁄16 1CSA File No. LR-12798.
UL File No. E-23018 — 1⁄4"–4".
Straight Connectors (with Insulated Throat)
45° Connectors —Malleable Iron/Zinc Plated
45° Connectors —Malleable Iron/Zinc Plated(with Insulated Throat)
90° Connectors —Malleable Iron/Zinc Plated
90° Connectors —Malleable Iron/Zinc Plated(with Insulated Throat)
Liquidtight Flexible Metal Conduit and Connectors
F-23
Fittings
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LT-200 3⁄8 1.81 0.50 1.06 100LT-201 1⁄2 1.88 0.61 1.19 100LT-202 3⁄4 2.03 0.56 1.44 100LT-203 1 2.28 0.63 1.75 50LT-204 11⁄4 2.59 0.69 2.44 40LT-205 11⁄2 2.78 0.78 2.75 20LT-206 2 3.22 0.78 3.53 20LT-207 21⁄2 3.53 0.84 4.28 1LT-208 3 3.91 0.88 4.72 1LT-209 31⁄2 4.04 0.91 5.42 1LT-210 4 4.16 0.94 5.91 1UL File No. E-23018.
A
B
C
A
B
C
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LT-290 3⁄8 1.88 1.38 0.50 100LT-291 1⁄2 2.00 1.41 0.50 100LT-292 3⁄4 2.19 1.66 0.56 100LT-293 1 2.56 1.88 0.63 50LT-294 11⁄4 3.00 2.00 0.69 40LT-295 11⁄2 3.38 2.56 0.78 20LT-296 2 4.06 3.00 0.78 10LT-297 21⁄2 5.03 3.72 0.84 1LT-298 3 5.63 4.66 0.88 1LT-299 31⁄2 6.10 4.82 0.91 1LT-2910 4 6.56 4.97 0.94 1UL File No. E-23018.
A
B
C
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LT-890 3⁄8 1.88 1.38 0.50 100LT-891 1⁄2 2.00 1.41 0.50 100LT-892 3⁄4 2.19 1.66 0.56 100LT-893 1 2.56 1.88 0.63 50LT-894 11⁄4 3.00 2.00 0.69 20LT-896 2 4.06 3.00 0.78 10LT-897 21⁄2 5.03 3.72 0.84 1
A
B
C
CONDUIT STD.CAT. NO. SIZE (IN.) CTN.
SR 101 1⁄2 500SR-102 3⁄4 500SR-103 1 500SR-104 11⁄4 250SR-105 11⁄2 250SR-106 2 250Material: Neoprene
Straight Connectors —Die Cast Zinc
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C CTN.
LT-800 3⁄8 1.81 0.50 1.06 100LT-801 1⁄2 1.88 0.61 1.19 100LT-802 3⁄4 2.03 0.56 1.44 100LT-803 1 2.28 0.63 1.75 50LT-804 11⁄4 2.59 0.69 2.44 40LT-805 11⁄2 2.78 0.78 2.75 20LT-806 2 3.22 0.78 3.53 20LT-807 21⁄2 3.53 0.84 4.28 1LT-808 3 3.91 0.88 4.72 1LT-809 31⁄2 4.04 0.91 5.42 1LT-810 4 4.16 0.94 5.91 1CSA File No. LR-12798.
Straight Connectors —Die Cast Zinc (with Insulated Throat)
90° Connectors —Die Cast Zinc
90° Connectors — Die Cast Zinc (with Insulated Throat)
Sealing O-Rings
Non-Metallic Sheathed Cable Fittings
F-24
Fitti
ngs
Fig. 1
• High-impact thermoplastic: UL 94-V1
• Features push-in design
• Captive locking wedge secures cablewith single squeeze of standardelectrician’s pliers
• Provides excellent insulation, strain-relief and high pull-out value
Snap captive locking wedge intoconnector’s cavity.
Press locking wedge into cavity thatlocks onto cable.
Cat. No. 3201 is ideal for multiple flexiblecords and cable.
STD.CAT. NO. DESCRIPTION CTN.
NC-501SC 1⁄2" Hit Lock® Connector 500NC-501DBL-SC 1⁄2" Double Hit Lock® Connector 500NC-502SC 3⁄4" Hit Lock® Connector 100SB1216-SC Twist It Bushing For Metal Studs 50UL File No. E-17583.
.400"
.580"
1.030"
1.250"1.000"
1.120"
1.300"
.580"
2.485"
1.315"
.115"
NC-501-SC
NC-501-SCNC-501DBL-SC
NC-502-SC SB1216-SC
Hit Lock® Connectors
All Plastic Connector for NM Cable and Flexible Cord
HHoleSize
HHoleSize
Fig. 2
Size RangeCAT. NO. DESCRIPTION
3300 For use with 10-2, 12-2 and 14-2 NM cables; 18-2 and 18-3 SJ and SJO cords and 18-2 SV, SVO, SJT and SJTO cords, single or multiple; cord capacity .125–.300" diameter
3201-TB For use with 10-3, 12-3, 14-3, 10-2, 12-2, 4-2 NM cables; multiple (2) 12-2 and 14-2 NM cables; single and multiple flexible cords in wire range .300–.600"
3202 For use with 8-3 and 6-3 NM cables; (2) 14-3, 14-2, 12-2 and 10-2 NM cables; single and multiple flexible cords in wire range .500–.850"
Temperature Rating: 105° C.CSA File Nos. 584 and 2884.UL File No. E-17583.
DIMENSIONS (IN.) MAX THK. STD. CAT. NO. KO SIZE (IN.) FIG. A B C D E ENCLOSURE H (IN.) CTN.
3300 1⁄2 2 11⁄32 15⁄16 3⁄8 .880 .795 .080 5⁄16 x 9⁄16 5003201-TB 1⁄2 1 111⁄32 1 7⁄16 .880 .795 .080 21⁄32 dia. 5003202 3⁄4 1 11⁄2 15⁄16 7⁄16 1.100 1.005 .090 7⁄8 dia. 250Temperature Rating: 105° C.CSA File Nos. 584 and 2884.UL File No. E-17583.
A
A C
B
B
C
Non-Metallic Sheathed Cable Fittings
F-25
Fittings
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B C D E CTN.
NC-850 1⁄2 .050 .950 1.312 .650 8–32 x 3⁄4 1,000NC-851 3⁄4–1 .050 1.250 1.750 .760 8–32 x 1 500NC-852 1–1⁄4 .062 1.625 2.125 .760 10–32 x 1 250NC-853 1–1⁄2 .062 1.970 2.500 .785 10–32 x 12 100
A
B D
C
E
A Max.
A Min.
DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-2200-C 3⁄8 0.12 0.63 0.98 500
B
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
NC-201 1⁄2 0.40 0.95 1.87 250NC-202 3⁄4 0.50 1.10 1.84 200NC-203 1 0.62 1.14 2.00 100NC-204 11⁄4 0.50 1.38 2.28 100NC-205 13⁄8 0.75 1.61 2.49 50NC-206 2 0.90 2.04 3.35 50CSA File No. LR-12798.
UL File No. E-17583.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
NC041 11⁄4 0.27 0.75 2.02 100NC-051 11⁄2 0.54 0.95 2.50 50NC-061 2 0.75 1.12 3.41 40UL File No. E-15170 — 11⁄4"–11⁄2".
UL File No. E-17583 — 2".
1–11⁄16"
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-210 3⁄8 (1⁄2 KO) 0.13 0.65 1.56 250XC-211-SC 3⁄8 0.24 0.63 1.59 200XC-222-SC 3⁄8 0.24 0.63 1.59 200
CONDUIT/CABLE FMC (IN.) AC MCC MCI
Max. Size 3⁄8 10/2 .565 .565Min. Size 3⁄8 14/2 .425 .425
CSA File No. LR-12798.
UL File No. E1383.
B
A Max.A Min.
• For use withaluminum, smooth,extruded metal–cladcable. (min. dia. .410— max. dia. .500).
NM Clamp TypeConnector — Die Cast Zinc B
A Max.A Min.
B
A Max.A Min.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
NC301 3⁄8 (1⁄2 KO) 0.18 0.64 1.16 1,000NC-302 3⁄4 0.41 0.82 1.87 500NC-303 1 0.34 0.94 2.01 250CSA File No. LR-12798.
UL File No. E-17583.
Connectors Clamp Type Non-Watertight — Die Cast Zinc
Duplex ClampType Connector — Die Cast Zinc
NM Flex Connectors Saddle Type —Die Cast Zinc
Tilt-In ConnectorMetallic Steel —Electro-Galvanized
Clamp TypeConnector —Die Cast Zinc
Armored Cable/Flexible Metallic Conduit Fittings
F-26
Fitti
ngs
CONDUIT UNIT STD.CAT. NO. SIZE (IN.) QTY. CTN.
XC-400 3⁄8 (1⁄2 KO) 50 100XC-401 1⁄2 25 100XC-402 3⁄4 25 100XC-403 1 25 100XC-404 11⁄4 5 10XC-405 11⁄2 10 10XC-406 2 10 10XC-407 21⁄2 5 5XC-408 3 5 5UL File No. E-1383 1⁄2"–3⁄4".
UL File No. E-23018 1"–3".3⁄8"–3⁄4" — Steel.
CONDUIT UNIT STD.CAT. NO. SIZE (IN.) QTY. CTN.
XC-901 1⁄2 25 100XC-902 3⁄4 25 100XC-903 1 25 100XC-904 11⁄4 5 10XC-905 11⁄2 10 10XC-906 2 10 10XC-907 21⁄2 5 5XC-908 3 5 51⁄2"–3⁄4"— Steel.
CONDUIT UNIT STD.CAT. NO. SIZE (IN.) QTY. CTN.
XC-490 3⁄8 (1⁄2 KO) 50 100XC-491 1⁄2 25 100XC-492 3⁄4 25 50XC-493 1 25 25XC-494 11⁄4 10 10XC-495 11⁄2 10 10XC-496 2 5 5XC-497 21⁄2 1 1XC-498 3 1 1UL File No. E-1383 3⁄8" & 3⁄4".
UL File No. E-23018 1"–3".3⁄8"–3⁄4" — Steel.
NOTE: For die cast armoredcable/flexible metallic conduitfittings and combination fittings,refer to the Steel City® Die CastConduit Fittings section.
XC-490
Straight Squeeze-Type Connectors —Malleable Iron or Stamped Steel/Zinc Plated
Straight Squeeze-Type Connectors — InsulatedMalleable Iron or Stamped Steel/Zinc Plated
Clamp Straight Set, 90°and Duplex Connectors
Straight SqueezeType Connectors — Die Cast Zinc90° Angle Squeeze-Type Connectors —
Steel or Malleable Iron/Zinc Plated
DIMENSIONS (IN.) STD.CAT. NO. FIG. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-269 1 3⁄8 (1⁄2 KO) 0.45 0.60 0.96 500XC-270 1 1⁄2 0.74 0.92 1.43 250XC-272 1 3⁄4 0.88 1.10 1.59 250XC-273 2 1 1.10 1.35 1.60 100XC-274 2 11⁄4 1.48 1.65 1.91 100XC-275 2 11⁄2 1.68 2.00 2.12 50XC-276 3 2 2.12 2.47 2.54 40XC-277 3 21⁄2 2.71 3.08 2.88 10XC-278 3 3 3.15 3.60 3.88 5XC-278A 3 31⁄2 3.20 4.03 5.04 1XC-2710 3 4 3.15 4.25 5.04
Armored Cable/Flexible Metallic Conduit Fittings
F-27
Fittings
DIMENSIONS (IN.) STD.CAT. NO. FIG. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-870 1 1⁄2 0.74 0.92 1.43 250XC-872 1 3⁄4 0.88 1.10 1.59 250XC-873 2 1 1.10 1.35 1.60 100XC-874 2 11⁄4 1.48 1.65 1.91 50XC-875 2 11⁄2 1.68 2.00 2.12 50XC-876 3 2 2.12 2.47 2.54 10XC-877 3 21⁄2 2.71 3.08 2.88 10XC-878 3 3 3.15 3.60 3.88 5XC-879 3 31⁄2 3.20 4.03 5.04 1XC-8710 3 4 3.15 4.25 5.04 1UL File No. E-17909 — 1⁄2"–3⁄4".
UL File No. E-23018 — 11⁄4".
CSA File No. LR-12798.
Fig. 2 Fig. 3
A M
in.
A M
ax.
A M
in.
A M
ax.
B B
N2 N2N1 N1
N3N3
TRADE DIMENSIONS (IN.) F GCAT. NO. SIZE (IN.) A B C D E THREADS SIZE RANGE
XC-201 1⁄2 125⁄64 17⁄64 13⁄32 155⁄64 13⁄8 1⁄2–14NPS 10–24 x 7⁄8 .40–.95XC-202 3⁄4 11⁄2 11⁄4 1⁄2 153⁄64 13⁄8 3⁄4–14NPS 10–24 x 7⁄8 .50–1.10XC-203 1 13⁄4 123⁄32 9⁄16 29⁄32 17⁄8 1–11 1⁄2NPS 10–24 x 7⁄8 .62–1.14XC-204 11⁄4 17⁄8 157⁄64 9⁄16 247⁄64 27⁄32 11⁄4–11 1⁄2NPS 10–24 x 7⁄8 .50–1.38All dimensions are approximated to the nearest 1⁄64".
A
B
C
D
E
G Size
F Threads
Straight Squeeze-Type Connectors — Insulated — Die Cast Zinc
Fig. 1
B
C
F Thread
A M
in.
A M
ax.
DE
Squeeze Type — BX Flex Connectors
Armored Cable/Flexible Metallic Conduit Fittings
F-28
Fitti
ngs
1. Simply snap into place. No locknuts required! 2. Insert cord and twist set screw. Connectortightens as screw is set.
Simple, fast steps to install the Steel City® Cable Lok®.
• Simple, one-piece installation with no locknuts
• Screw designed for exceptional pullout resistance
• Captive screw ensures that the screw is intact forinstallation and resists backing out after installation
• Corrosion-resistant, zinc-chromatic plating
• Positive grounding
• Vibration-resistant screw design
• UL Listed and CSA Certified
Material: Body: Steel (spring steel); Finish: Zinc; Insulator: Nylon; Temp.: 105°C
Listing: UL, CSA Listed
Snap-In Fitting for MC Cable — SteelSTD.
CAT. NO. DESCRIPTION CTN.
XC-130 Steel Snap-In Fitting for MC cable 500(14-2+G to 10-3+G)
Steel City® Cable Lok®
SIZE AC AC ALUMINUM MC (I) MC (I) FLEX STD.CAT. NO. RANGE (IN.) STEEL INTERLOCKED STEEL ALUMINUM RW CTN.
14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 3⁄ 8 Steel 50XC-730 .450/.610 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 & AL
1⁄2 KO 10/2 10/2 10/3 1⁄2" KO 10/2 10/314/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 50
XC-731 .450/.610 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 —1⁄2 KO 10/2 10/2 10/3 1⁄2" KO 10/2 10/3
10/3 10/4 10/5 10/4 10/5 3⁄ 8 Steel 25XC-732 .610/.875 8/3 8/4 — 8/3 8/4 — & AL
3⁄4 KO 6/2 6/2 3⁄4" KO14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 25
XC-7300 .450/.610 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 —1⁄2 KO 10/2 10/2 10/3 1⁄2" KO 10/2 10/3
UL File No. E-1383.
CSA File No. LR-12798.
Steel City® Cable Lok®
• O.D. for over armor 0.400"–0.510"
• No set screws, locknuts or tools are required to attach MC cable to a box or enclosure
• One-piece spring-steel construction
• Accommodates the widest range of MC cablesizes in the industry — 14-2 to 10-3
• Compact, low-profile design saves space in the box or enclosure
• Fittings can be used in adjacent knockouts in the corner of the box
• Removable and reusable
• Ideal for commercial construction or prefabricatedelectrical wiring assemblies
Armored Cable/Flexible Metallic Conduit Fittings
F-29
Fittings
Fig. 2 Fig. 3
Fig. 4Fig. 5
Fig. 1
DIMENSIONS (IN.) STD.CAT. NO. FIG. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-290 1 3⁄8 (1⁄2 KO) 0.40 0.63 1.80 500XC-291 1 1⁄2 0.65 1.00 2.08 250XC-292 1 3⁄4 0.83 1.25 2.27 100XC-293 2 1 1.27 1.50 2.60 50XC-294 2 11⁄4 1.49 1.85 3.10 30XC-295 3 11⁄2 1.51 2.47 6.05 5XC-296 3 2 1.51 2.47 6.05 5XC-297 4 21⁄2 2.45 3.50 7.75 2XC298 5 3 3.07 4.02 8.88 1XC-299 4 31⁄2 3.63 4.34 12.75 1XC-2910 4 4 3.68 5.17 12.75 1UL File No. E-1383.
CSA File No. LR-18130M57.
Insulated Die Cast ZincDIMENSIONS (IN.) STD.
CAT. NO. FIG. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-890 1 3⁄8 0.40 0.63 1.81 500XC-891 1 1⁄2 0.65 0.97 2.18 250XC-892 1 3⁄4 0.77 1.12 2.38 100XC-893 2 1 1.06 1.40 2.87 50XC-894 2 11⁄4 1.34 1.65 3.93 30XC-895 3 11⁄2 1.51 2.47 6.05 5XC-896 3 2 1.51 2.47 6.05 5XC-897 4 21⁄2 2.45 3.50 7.75 2XC-898 5 3 3.07 4.02 8.88 1XC-899 4 31⁄2 3.63 4.34 12.75 1XC-8910 4 4 3.68 5.17 12.75 1UL File No. E-1383.
CSA File No. LR-12798.
B
A Min.
B Max.
G
H
Threads
AB
C
D
E
FG
HThreads Threads
ThreadsThreads
AB
D
E
FC
AB
D
EF
G
C
AB
C
D
EF
G
For use with Metal Clad Cable
A Max.A Min.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-280 3⁄8 (1⁄2 KO) 0.18 0.64 1.16 1,000UL File No. E-1383.
CSA File No. LR-18130M57.
CONDUIT DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-210 3⁄8 (1⁄2 KO) 0.13 0.65 1.56 250CSA File No. LR-18130M57.
B
90° Clamp Type Connectors —Die Cast Zinc
Clamp Type Connector —Die Cast Zinc
Duplex Clamp Type Connector —Die Cast Zinc
XC-290
Armored Cable/Flexible Metallic Conduit Fittings
F-30
Fitti
ngs
KO UNIT STD.CAT. NO. CONDUIT SIZE (IN.) SIZE (IN.) QTY. CTN.
100-TB 3⁄8 1⁄2 50 500100BP 3⁄8 1⁄2 250 1,000
• Packed in polybags
• Available bulk packed — 10,000 per carton
• Plastic
4 MetalGrounding Tabs
PlasticBody
A
B
C
• No locknut required
• No special tools required
• High-impact thermoplasticwith steel insert
NOTE: For die cast armored cable/flexible metallic conduit fittings and combination fittings, refer to the Steel City® Die Cast Conduit Fittings section.
DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-220SC 3⁄8 (1⁄2 KO) 0.38 0.63 0.84 1,000XC-221 1⁄2 0.74 0.94 1.46 250XC-821 1⁄2 0.74 0.94 1.46 250XC-220 and XC-221: UL File No. E-1383 3⁄8".
UL File No. E-23018 1⁄2".
XC-821: UL File No. E-1275 1⁄2".
A Max.A Min.
BA Max.A Min.
B
XC-221XC-821
A Max.
A Min.
DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-2200-C 3⁄8 0.12 0.63 0.98 500B
FITS STANDARD UNIT STD.CAT. NO. CABLE RANGE SIZE QTY. CTN.
IT 100 SC 14/2–14/3–12/2 0 100 100IT-101 14/4–12/3–6/1–4/1 1 100 35IT-102 12/4–10/2–10/3–2/1 2 50 50IT-103 10/4–8/2–8/3–1/1 3 50 50IT-104 8/4–6/2–6/3–4/2–4/3–6/4 4 50 50Ordered by Bags.
Snap-In Connector for Flexible Metal Conduit — 105° C Rated
BX Flex Bushings — Anti-Short
Straight Set Screw Connectors Die Cast Zinc — Non-Insulated
BX Flex ConnectorsSaddle Type —Die Cast Zinc
XC-220
Armored Cable/Flexible Metallic Conduit Fittings, Service Caps
F-31
Fittings
DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
XC-240 3⁄8 (1⁄2 KO) 1.31 0.92 500XC-241 1⁄2 1.38 0.92 500XC-242 3⁄8 1.62 1.12 125XC-243 1 1.94 1.37 125XC-244 11⁄4 2.12 1.75 50XC-245 11⁄2 2.31 2.13 50XC-246 2 2.58 2.67 50UL File No. E-23018.
CSA File No. LR-18130M57 3⁄8"–1⁄2".
A
B
DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
XK 241 1⁄2 1.81 0.92 250XK-242 3⁄4 2.09 1.12 250XK-243 1 2.41 1.37 125XK-244 11⁄4 2.75 1.81 50XK-245 11⁄2 3.05 2.12 50XK-246 2 3.28 2.67 50UL File No. E-23018.
A
B
A
B
DIMENSIONS (IN.) STD.CAT. NO. SIZE (IN.) A B CTN.
XC-840 3⁄8 (1⁄2 KO) 1.31 0.92 500XC-841 1⁄2 1.38 0.92 500XC-842 3⁄4 1.62 1.12 125XC-843 1 1.94 1.37 125XC-844 11⁄4 2.12 1.75 50XC-845 11⁄2 2.31 2.13 50XC-846 2 2.58 2.67 50UL File No. E-23018.
CSA File No. LR-18130M57 3⁄8"–1⁄2".
A
B
Screw-In Connectors Die Cast Zinc — Non-Insulated
Screw-In Connectors Die Cast Zinc —Insulated
Screw-In CouplingsDie Cast Zinc
CONDUIT STD.CAT. NO. SIZE (IN.) NO. HOLES SIZE CTN.
SH-101 1⁄2 4 4 19⁄64" 50SH-102 3⁄4 5 2 (3⁄8") 3 (13⁄32") 50SH-103 1 5 2 (7⁄16") 3 (1⁄2") 10SH-104 11⁄4 5 2 (19⁄32") 3 ( 5⁄8") 10SH-105 11⁄2 6 2 (19⁄32") 1 (7⁄16") 3 (3⁄4") 5SH-106 2 6 2 (3⁄4") 3 (1") 1 (17⁄32") 5SH-107 21⁄2 7 3 (7⁄8") 1 (1") 3 (15⁄16") 1SH-108 3 7 4 (11⁄8") 3 (13⁄4") 1SH-109 31⁄2 4 4 (13⁄4") 2 (1⁄8") 1SH-110 4 4 4 (13⁄4") 2 (11⁄8") 1CSA File No. LR-12798.
UL File No. E-13938.
Aluminum Service Caps —Clamp Type forRigid/Intermediateor Thinwall
TRADE RUBBER GROMMET OPENING (IN.) STD.CAT. NO. SIZE (IN.) FITS CABLE A B CTN.
WT203A 1 3#8 .500 .750 100WT-203B 1 3#6 .563 .844 100WT-203C 1 3#4 .625 .938 100WT-204A 11⁄4 3#3 .625 1.000 50WT-204B 11⁄4 3#2 .580 .960 50WT-204C 11⁄4 3#1 .660 1.090 50WT-204D 11⁄4 3#1/0 .750 1.125 50WT-205A 11⁄2 3#1/0 & 3#2/0 .735 1.240 20WT-205B 11⁄2 3#2/0 & 3#3/0 .875 1.375 20WT-205C 11⁄2 3#2/0 & 3#3/0 .938 1.438 20WT-206A 2 3#1/0 & 3#2/0 .735 1.240 20WT-206B 2 3#2/0 & 3#3/0 .875 1.375 20WT-206C 2 3#2/0 & 3#3/0 .938 1.438 20WT-206D 2 3#4/0 .890 1.550 20WT-206E 2 3#4/0 1.063 1.688 20
For Underground Feeder CableUF201 1⁄2 2#14 .210 .440 250UF-202 3⁄4 3#14 .220 .660 250
• For type SE, style U, flat; 2 insulating conductors, 1 bare
A
BWater-Tight Connectors
Cable Caps, Protector, Straps and Clips; Threaded Rod and Coupling
F-32
Fitti
ngs
STD.CAT. NO. DESCRIPTION CTN.
CP-1 Steel 100
Cable Protector
13⁄8"
19⁄16"
FITS DIMENSIONS (IN.) STD.CAT. NO. CABLE A B C CTN.
50130 To 2/0–3 5.00 3.31 4.75 1050130A To 4/0–3 6.75 4.62 6.00 5With Split InsulatorSC1000 3#3–2 2.37 2.12 2.25 25SC2001 3#3/0–4/0 4.93 3.12 3.75 10Extra large body for additional wiring space.
Service Cable Caps — Oval
A
B
C
A
C
B
1"
11⁄8"
3⁄8" STD.CAT. NO. DESCRIPTION CTN.
NS 100 Steel 1,000
Cable Clip
FITS SHELF SHIP STD.CAT. NO. CABLE CTN. CASE CTN.
SE-100 3#8, 3#6, 3#4 100 1,000 1,000SE101 3#3, 3#2 100 1,000 1,000SE102 3#1, 3#0, 3#1/0, 3#2/0 25 250 250SE103 3#3/0, 3#4/0 25 250 250
FITS SHELF SHIP STD.CAT. NO. CABLE CTN. CASE CTN.
SE-900 3#8, 3#6, 3#4 100 1,000 1,000SE901 3#3, 3#2 100 1,000 1,000SE902 3#1, 3#0, 3#1/0, 3#2/0 25 250 250SE903 3#3/0, 3#4/0 25 250 250
Service Cable Straps —Two-Hole
Service Cable Straps —One-Hole
DIMENSIONS (IN.) STD.CAT. NO. ROD SIZE (IN.) A B CTN.
H-195-1/4 1⁄4 3⁄4 3⁄8 1,000H-195-3/8 3⁄8 1 1⁄2 500H-195-1/2 1⁄2 1 5⁄8 500H-195-5/8 5⁄8 11⁄2 3⁄4 50
DATA FOR PR ESSURE PIPINGROD ULTIMATE‡ ROOT AREA NOMINAL MAX. SAFE STD.
CAT. NO. SIZE (IN.) LOAD IN LBS. THREAD PIPE SIZE (IN.) LOAD AT 450° CTN.
R628-6 FT. 1⁄4–20 900 .027 — — 300R638-6 FT. 3⁄8–16 1,900 .068 3⁄4–2 610 150R648-6 FT. 1⁄2–13 3,500 .126 21⁄2–31⁄2 1,130 60R1028-10 FT. 1⁄4–20 900 .027 — — 500R1038-10 FT. 3⁄8–16 1,900 .068 3⁄4–2 610 250R1048-10 FT. 1⁄2–13 3,500 .126 21⁄2–31⁄2 1,130 100‡ Load Ratings based on safely factor of three.
R-Series Continuous ThreadRod — Galvanized
H-195 SteelRod Coupling
STD. WT./100CAT. NO. CTN. (LBS.)
FS100-SC 250 1.70
One-Hole Strap for 3⁄8"Armored Cable and Flexible Metal Conduit
Beam Clamps
F-33
Fittings
DIMENSIONS (IN.)CAT. NO. O.D. OF CONDUIT NOM. CONDUIT OR STD.& SIZE OR PIPE PIPE SIZE CTN.
RCS Clamp — Steel
RCS-1/2 .840 1⁄2 50RCS-3/4 1.050 3⁄4 50RCS-1 1.315 1 50RCS-1-1/4 1.660 11⁄4 50RCS-1-1/2 1.900 11⁄2 50RCS-2 2.375 2 50
RC Clamp — Malleable Iron
RC-3/8 .675 3⁄8 50RC-1/2 .840 1⁄2 50RC-3/4 1.050 3⁄4 50RC-1 1.315 1 50RC-1-1/4 1.660 11⁄4 50RC-1-1/2 1.900 11⁄2 50RC-2-SC 2.375 2 50RC-2-1/2 2.875 21⁄2 25RC-3 3.500 3 25RC-3-1/2 4.000 31⁄2 25RC-4-SC 4.500 4 20
• For mounting pipe or conduit at right angles to the beam
• Add a SS316 suffix for stainless steel
• Add a HDG suffix for hot-dip galvanizedRCS Series
DIMENSIONS (IN.)CAT. NO. O.D. OF CONDUIT NOM. CONDUIT OR STD.& SIZE OR PIPE PIPE SIZE CTN.
PC Clamp — Malleable Iron
PC-3/8 .675 3⁄8 50PC 1/2 .840 1⁄2 50PC-3/4 1.050 3⁄4 50PC-1 1.315 1 50PC-1-1/4 1.660 11⁄4 25PC-1-1/2 1.900 11⁄2 25PC-2 2.375 2 25PC-2-1/2 2.875 21⁄2 25PC-3 3.500 3 10PC-3-1/2 4.000 31⁄2 10PC-4 4.500 4 10
DIMENSIONS (IN.)CAT. NO. O.D. OF CONDUIT NOM. CONDUIT OR STD.& SIZE OR PIPE PIPE SIZE CTN.
EC Clamp — Malleable Iron
EC 1/2 .840 1⁄2 50EC-3/4 1.050 3⁄4 50EC-1 1.315 1 25EC-1-1/4 1.660 11⁄4 25EC-1-1/2 1.900 11⁄2 25EC-2 2.375 2 25EC-2-1/2 2.875 21⁄2 10
EC Series• For mounting pipe or conduit
vertically across the beam
• Add a HDG suffix for hot-dip galvanized
PC Series• For mounting pipe or conduit
parallel to the beam
• Add a HDG suffix for hot-dip galvanized
EC Series
PC Series
Conduit/Pipe to Beam Clamps
Conduit/Pipe to Beam Clamps
BASE SIZE JAW(IN.) OPENING TAPPING OF BASE LOAD STD.
CAT. NO. A B INCHES AND BACK HOLES RATING‡ CTN.
510 27⁄32 11⁄8 5⁄8 1⁄4–20 400 100511-SC 27⁄32 11⁄8 5⁄8 10–24 400 100500-SC 1 11⁄4 15⁄16 1⁄4–20 450 50509 1 11⁄4 15⁄16 10–24 375 100501 11⁄2 15⁄8 7⁄8 5⁄16–18 800 50502 2 2 1 3⁄8–16 1,300 50503-SC 25⁄8 21⁄2 1 1⁄2–13 1,300 20507 21⁄2 23⁄8 13⁄8 1⁄2–13 1,700 20508 21⁄2 23⁄8 21⁄8 1⁄2–13 1,700 10‡Safety Factor of 3.Loan Ratings based on bottom hole of Beam Clamp.CSA File No. LR-52208.
Beam Clamps — Malleable Iron,Electroplated Finish
Beam Clamps
3⁄8"Min
D
A
SIZE DIMENSIONS (IN.) STD. CAT. NO. (IN.) TAPPED A B C D CTN.
BC1-TB 1 1⁄4–20 111⁄16 13⁄8 5⁄8 13⁄16 250BC2-TB 215⁄16 3⁄8–16 21⁄8 21⁄16 3⁄4 111⁄16 25Material: SteelFinish: Zinc Plated
C B
Cup Point
5/16-18 x 13⁄8" hex head, cup point,hardened steel, cap screw note1
Ground Clamps, Pipe Hangers
F-34
Fitti
ngs
For hanging conduit (rigid or EMT) and pipe.The 6H series hangers are fast, easy and economicalto use. May be fastened directly to a #500 beamclamp through a hole in the base of the hanger bymeans of a 1⁄4-20 stove bolt or suspended on 1⁄4"hanger rod.
All Steel City 6H Hanger Bolts include a combination Slot-Phillips Head.
-
6H Without bolt. 6H-B With boltand hex nut.
6H-T Threadedwithout bolt.
6H-TB Threadedwith bolt.
D Dia.
6H Series Conduit and Pipe Hangers — With Bolt
RIGID CONDUITOR PIPE EMT DIMENSIONS (IN.) LOAD STD.
CAT. NO. SIZE (IN.) SIZE (IN.) A B C D (DIA.) RATING CTN.
6H0 B 3⁄8–1⁄2 1⁄2 3⁄4 .045 121⁄32 9⁄32 500 1006H0 TB 3⁄8–1⁄2 1⁄2 3⁄4 .045 127⁄32 9⁄32 500 1006H1-B 3⁄4 3⁄4 7⁄8 .045 131⁄32 9⁄32 500 1006H1-TB 3⁄4 3⁄4 7⁄8 .045 2 9⁄32 9⁄32 500 1006H2-B 1 1 7⁄8 .045 2 3⁄8 9⁄32 500 1006H2-B 1 11⁄4 7⁄8 .045 2 23⁄32 9⁄32 500 1006H3-B 11⁄4 11⁄2 7⁄8 .045 2 7⁄8 9⁄32 500 1006H4-B 11⁄2 — 1 .071 3 3⁄8 11⁄32 500 1006H5-B 2 2 11⁄4 .071 3 29⁄32 11⁄32 500 506H6-B 21⁄2 — 11⁄4 .071 4 9⁄32 11⁄32 500 506H7-B 3 — 11⁄4 .071 5 3⁄16 11⁄32 500 256H8-B 31⁄2 — 11⁄4 .071 5 7⁄16 11⁄32 500 256H9-B 4 4 11⁄4 .071 5 7⁄8 11⁄32 500 10UL File No. E-160899.Add SS suffix to part number for Stainless Steel.Load rating is 500 lbs. with a safety factor of 3.Available with or without closure bolt.Standard finishes: Electro-Galvanized. (Add SS suffix for Type 302 Stainless Steel)
6H Series Conduit and Pipe Hangers — Without Bolt
RIGID CONDUITOR PIPE EMT DIMENSIONS (IN.) LOAD STD.
CAT. NO. SIZE (IN.) SIZE (IN.) A B C D (DIA.) RATING CTN.
6H0 3⁄8–1⁄2 1⁄2 3⁄4 .045 121⁄32 9⁄32 500 1006H0 T 3⁄8–1⁄2 1⁄2 3⁄4 .045 127⁄32 9⁄32 500 1006H1 3⁄4 3⁄4 7⁄8 .045 131⁄32 9⁄32 500 1006H1-T 3⁄4 3⁄4 7⁄8 .045 2 9⁄32 9⁄32 500 1006H2 1 1 7⁄8 .045 2 3⁄8 9⁄32 500 1006H2 1/2 — 11⁄4 7⁄8 .045 2 23⁄32 9⁄32 500 1006H3-SC 11⁄4 11⁄2 7⁄8 .045 2 7⁄8 9⁄32 500 1006H4 11⁄2 — 1 .071 3 3⁄8 11⁄32 500 1006H5 2 2 11⁄4 .071 3 29⁄32 11⁄32 500 506H6 21⁄2 — 11⁄4 .071 4 9⁄32 11⁄32 500 506H7 3 — 11⁄4 .071 5 3⁄16 11⁄32 500 256H8 31⁄2 — 11⁄4 .071 5 7⁄16 11⁄32 500 256H9 4 4 11⁄4 .071 5 7⁄8 11⁄32 500 10UL File No. E-160899.Add SS suffix to part number for Stainless Steel.Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt.Standard finishes: Electro-Galvanized. (Add SS suffix for Type 302 Stainless Steel)
Without Bolt
CONDUIT STD.CAT. NO. SIZE (IN.) CTN.
GC-203-B 1⁄2; 1 200
Ground Clamps — Die CastZinc, Brass Colored
• Two-screw ground connection for armored ground wire
F-35
Non-Metallic Rigid Conduit, Fittings and Accessories
The new, revolutionary Carlon® PVC Conduit Repair System significantlyreduces the time and money associated with repairing broken PVCconduits, a.k.a. “stub-ups”, in concrete slabs.
The system includes a line of couplings, adapters, reamers and plugsdesigned to enable contractors to quickly and easily repair broken PVCconduits without having to chip away and repour concrete, while stillmaintaining the inside diameter of the conduit. Simply cut off the brokenconduit, ream the I.D. of the conduit and insert a coupling or adapter. It’s that easy. A job that normally takes 20 minutes can now be done in 2 minutes or less!
Features:• cUL–US Listed
• PVC repair fittings are listed in accordance with the NEC® andSection 352.6
• Non-metallic couplings, adapters and plugs won’t rust or corrode
• Available in sizes 1⁄2" through 2"
Benefits:• Saves time and money
• Maintains inside diameter of conduit
• Metallic reamers for extra strength, durability and longer life
• Quickly and easily repair broken PVC conduits
A job that normally takes 20 minutes —DONE in 2 minutes or less!
Carlon® PVC Conduit Repair System
Male Threaded Adapter
Reamer
Coupling
Reamer Kit
CouplingsCAT. NO. TRADE SIZE (IN.) STD. CTN.
E910D 1⁄2 25E910E 3⁄4 25E910F 1 15E910G 11⁄4 10E910H 11⁄2 10E910J 2 10
Plug
Schedule 40 PlugsCAT. NO. SIZE (IN.) COLOR CAT. NO. SIZE (IN.) COLOR CAT. NO. SIZE (IN.) COLOR STD. CTN.
HL-6XR 1⁄2 Red HL-6XB 1⁄2 Blue HL-6XY 1⁄2 Yellow 1 Bag of 50HL-10R 3⁄4 Red HL-10B 3⁄4 Blue HL-10Y 3⁄4 Yellow 1 Bag of 50HL-13AR 1 Red HL-13AB 1 Blue HL-13AY 1 Yellow 1 Bag of 50HL-16R 11⁄4 Red HL-16B 11⁄4 Blue HL-16Y 11⁄4 Yellow 1 Bag of 50HL-18R 11⁄2 Red HL-18B 11⁄2 Blue HL-18Y 11⁄2 Yellow 1 Bag of 50HL-21R 2 Red HL-21B 2 Blue HL-21Y 2 Yellow 1 Bag of 50
Male Threaded AdaptersCAT. NO. TRADE SIZE (IN.) STD. CTN.
E920D 1⁄2 25E920E 3⁄4 25E920F 1 15E920G 11⁄4 10E920H 11⁄2 10E920J 2 10
ReamersCAT. NO. TRADE SIZE (IN.) STD. CTN.
E910REAMD 1⁄2 12E910REAME 3⁄4 12E910REAMF 1 10E910REAMG 11⁄4 10E910REAMH 11⁄2 10E910REAMJ 2 10E910REAMKIT All sizes 5
Rigid Non-Metallic Conduit
Rigid Non-Metallic Conduit
F-36
Non-
Met
allic
Rig
id C
ondu
it, F
ittin
gs a
nd A
cces
sorie
s
CouplingE910_
Male Threaded AdapterE920_
PVC Conduit Repair FittingsE2969
Apply a uniform coat of cement.
Insert fitting.
Rotate 1/4 turn.
Instructions:
Broken conduit on jobsite
Cut broken conduit off flush.1
Insert plug to keep conduit clean/drythrough balance of rough-in. Oncerough-in is complete, remove plugand continue with Step 3.
2
With reamer tool and standard 1⁄2" drill, ream I.D. of conduit. It isrecommended to use a variablespeed drill. Use slower speed to avoid overheating the conduit.
3
The guide will direct the cutter; thestop will touch when completed.
4
Insert the coupling and cement into place using the cementmanufacturer’s instructions.
Cementing Instructions:
A. Clean socket I.D. and spigot O.D. of dirt and moisture.
B. Apply a uniform coat of cement tospigot end and push onto socketbottom, rotating 1/4 turn.
C. Allow time to set before disturbing.This will depend upon temperature.
5
Alternative to Conduit Repairs:Prior to concrete pour, measure and saw cut all conduit stub-ups to thethickness of the concrete pour. Insert plugs. Pour concrete flush to theconduit. When pour is complete, remove plugs and proceed with Step 3.This alternative method saves time/money by eliminating the need fortransitions or use of metal elbows.
F-37
Non-Metallic Rigid Conduit, Fittings and Accessories
Rigid Non-Metallic Conduit
Standard Radius
Standard Radius Elbow Dimensions
Schedule 40 Elbows
90°Elbow
45°Elbow
PLAIN BELLED PLAIN BELLEDEND END SIZE END END
ITEM CAT. NO. CAT. NO. (IN.) STD. CTN. STD. CTN.
90° ELBOW UA9AD UA9ADB 1⁄2 50 50UA9ADR-CAR UA9ADB 1⁄2 25 50
UA9AE UA9AEB 3⁄4 25 25UA9AFR-CTN UA9AFB-CTN 1 25 25
UA9AG UA9AGB 11⁄4 20 20UA9AH UA9AHB 11⁄2 25 25UA9AJ UA9AJB 2 20 20
UA9AK-CAR UA9AKB-CAR 21⁄2 10 10UA9AL UA9ALB 3 1 5UA9AM UA9AMB 31⁄2 1 20UA9AN UA9ANB 4 1 1UA9AP UA9APB 5 1 1UA9AR UA9ARB 6 1 1
45° ELBOW UA7AD UA7ADB 1⁄2 50 50UA7AE UA7AEB 3⁄4 25 25UA7AF UA7AFB 1 20 20
UA7AF-CAR UA7AFB 1 15 20UA7AG UA7AGB 11⁄4 20 20UA7AH UA7AHB 11⁄2 20 20UA7AJ UA7AJB 2 20 20
UA7AJ-CAR — 2 4 4UA7AK UA7AKB 21⁄2 20 20UA7AL UA7ALB 3 5 25UA7AM UA7AMB 31⁄2 1 20UA7AN UA7ANB 4 1 20UA7AP UA7APB 5 1 1UA7AR UA7ARB 6 1 1
30° ELBOW UA6AD UA6ADB 1⁄2 50 50UA6AE UA6AEB 3⁄4 25 25UA6AF UA6AFB 1 25 1UA6AG UA6AGB 11⁄4 20 20UA6AH UA6AHB 11⁄2 25 1UA6AJ UA6AJB 2 20 20UA6AK UA6AKB 21⁄2 10 20UA6AL UA6ALB 3 1 1UA6AM UA6AMB 31⁄2 1 1UA6AN UA6ANB 4 1 1UA6AP UA6APB 5 1 1UA6AR UA6ARB 6 1 1
221⁄2° ELBOW UA5AD — 1⁄2 1 —UA5AE — 3⁄4 1 —UA5AF — 1 1 —UA5AG — 11⁄4 1 —UA5AH — 11⁄2 1 —UA5AJ UA5AJB 2 25 1UA5AK — 21⁄2 20 —UA5AL UA5ALB 3 5 1UA5AM — 31⁄2 1 —UA5AN UA5ANB 4 1 1UA5AP UA5APB 5 1 1UA5AR UA5ARB 6 1 1
B MIN. CSIZE A (RADIUS) MIN.(IN.) (IN.) (IN.) (IN.)
1⁄2 .840 4 11⁄23⁄4 1.050 41⁄2 11⁄21 1.315 53⁄4 17⁄8
11⁄4 1.660 71⁄4 211⁄2 1.900 81⁄4 22 2.375 91⁄2 2
21⁄2 2.875 101⁄2 33 3.500 13 31⁄8
31⁄2 4.000 15 31⁄44 4.500 16 33⁄85 5.563 24 35⁄86 6.625 30 33⁄4
Integral Belled End DimensionsA
C
B
TRADE A (IN.) B (IN.) C (IN.)SIZE AT ENTRANCE AT BOTTOM SOCKET DEPTH(IN.) MAX. MIN. MAX. MIN. MAX. MIN.
1⁄2 .860 0.844 0.844 0.828 1.500 0.6523⁄4 1.074 1.054 1.056 1.036 1.500 0.7191 1.340 1.320 1.320 1.300 1.875 0.875
11⁄4 1.689 1.665 1.667 1.643 2.000 0.93811⁄2 1.930 1.906 1.906 1.882 2.000 1.0622 2.405 2.381 2.381 2.357 2.000 1.125
21⁄2 2.905 2.875 2.883 2.853 3.000 1.4693 3.530 3.500 3.507 3.477 3.125 1.594
31⁄2 4.065 3.965 4.007 3.977 3.250 1.6874 4.565 4.465 4.506 4.476 3.375 1.7505 5.643 5.543 5.583 5.523 3.625 1.9376 6.708 6.608 6.644 6.584 3.750 2.125
PLAIN BELLED PLAIN BELLEDEND END SIZE END END
ITEM CAT. NO. CAT. NO. (IN.) STD. CTN. STD. CTN.
111⁄4° ELBOW UA3AD — 1⁄2 1 —UA3AE — 3⁄4 1 —UA3AF — 1 1 —UA3AG — 11⁄4 1 —UA3AH — 11⁄2 1 —UA3AJ — 2 1 —UA3AK — 21⁄2 1 —UA3AL — 3 1 —UA3AM — 31⁄2 1 —UA3AN UA3ANB 4 1 1UA3AP — 5 1 —UA3AR — 6 1 —
Available in plain and integral belled end for use with non-metallic solvent weld fittings.
E23018ETL Listed to UL 651 incomplianceto the NEC®
Rigid Non-Metallic Conduit
F-38
Non-
Met
allic
Rig
id C
ondu
it, F
ittin
gs a
nd A
cces
sorie
s
Special Radius *Consult factory for additional sizes/configurationsSchedule 40 Elbows
PLAIN BELLEDPLAIN BELLED NOM. END ENDEND END DIAM. RADIUS STD. STD.
SEGMENT CAT. NO. CAT. NO. (IN.) (IN.) CTN. CTN.
90° ELBOW UA9CF UA9CFB 1 18 1 1UA9DF UA9DFB 1 24 1 1UA9EF UA9EFB 1 30 1 1UA9FF — 1 36 1 —UA9HF — 1 48 1 —UA9CG UA9CGB 11⁄4 18 1 1UA9DG UA9DGB 11⁄4 24 1 1UA9EG UA9EGB 11⁄4 30 1 1UA9FG UA9FGB 11⁄4 36 1 1UA9HG — 11⁄4 48
Recommended